P000115 Rev. E - Guardian Telecom Inc.
Contents
1. MICROPHONE NOISE REDUCING ELECTRET OPTIONAL MICROPHONE NOISE CANCELING DYNAMIC RECEIVER HEARING AID COMPATIBLE STANDARD MOUNTING VERTICAL WALL CONNECTION FITTINGS 1 2 NPT CONDUIT HUB Page 7 HARDWARE MATERIAL STAINLESS STEEL Guardian Telecom Inc Installation and Operation Model EP600 Compliance CANADIAN STANDARDS ASSOCIATION CSA REFERENCE NUMBER LR65547 23 CLASS I DIVISION 2 GROUPS A B C AND D STYLE 12 CLASS ZONE 2 GROUP IIC CLASS II DIVISION 1 amp 2 GROUPS E F AND G STYLE 21 CLASS II DIVISION 1 GROUPS E F AND G STYLE 22 CLASS II DIVISION 2 GROUP G UNDERWRITERS LABORATORIES UL LISTED 13X8 amp E117495 CLASS I DIVISION 2 GROUPS A B C AND D SIS CLASS II DIVISION 2 GROUPS F AND G STYLE 22 CLASS II DIVISION 2 GROUPS F amp G CONFORMITE EUROPEENNE CE EMC DIRECTIVE 89 336 EEC STYLE 12 LOW VOLTAGE DIRECTIVE 73 23 EEC ATEX DIRECTIVE 94 9 EC ENCLOSURE CSA 3R GUARDIAN TELECOM INC SR EP600 TELEPHONE TELEPHONE FOR USE IN e LR65547 HAZARDOUS LOCATIONS LISTED 13X8 CLASS I DIVISION 2 CLASS DIVISION 2 GROUPS A B C amp D GROUPS A B C amp D CLASS 1 ZONE 2 GROUP IIC CLASS 1 ZONE 2 GROUP IIC CLASS II DIVISION 1 amp 2 CLASS II DIVISION 2 GROUPS E F amp G GROUPS F amp G CSA ENCLOSURE TYPE 3R DOC amp FCC APPROVED R E N 0 4A CAT NO STYLE 12 L N 21 SEE USER G
2. maintenance or repairs To maintain hazardous area compliance the only field adjustment permitted See Warranty and is to change the tone pulse setting All other repairs or alterations must be Guardian Product Return carried out by Guardian Telecom or an Authorized Service Depot Page 5 Guardian Telecom Inc Installation and Operation Model EP600 Operation Once your Model EP600 Telephone has been properly installed and energized operation is identical to most other single line telephones Setting Tone Pulse Operation e Ensure that none of the electrical connection circuits are live e Loosen the five captive screws in the faceplate and swing the faceplate to the left If the set is installed on a vertical surface the faceplate will stay open like a book in this position Take care not to disturb the internal wiring e Set the Tone Pulse jumper for the desired operation For pulse set jumper See Figure 3 Setting between the center pin and the P for tone set it between the center pin Tone Rulse Operation and T e Replace the faceplate e Check the set visually for loose screws and trapped wires Check that the handset hangs freely in the cradle and that the handset cord is not trapped by the door e Check that the faceplate is snug to its gasket paying particular attention to the area around the cradle Check that the door closes flush to the housing e Apply power to the system e Test
3. Guardian Telecom Inc Industrial Communications Worldwide Hazardous Area Telephone Model EP600 Installation and Operation SE 8 4 d KE TIE 9 i d e DOE P000115 Rev E 11 23 2004 10 00 7552 10th Street N E Calgary Alberta Canada T2E 8W1 Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com 150 9001 Guardian Telecom Inc Installation and Operation Model EP600 Table of Contents EE 2 RE 3 FOIL e ee cal Z na Re Sr nd A ee 3 Installing the EP600 GEET 5 Maintenance sean den te te EA Eaa eee au eh le 5 Operati n esr a een rere ee Re Eeer 6 Setting Ton Puls Op ration nee tnt 6 Engineering Specifications sese eee ee eee eee eee 7 EELER eege eege 9 Rei 9 Warming EE 9 Service Telephone Number nn nat men nsc lasse focus ee 9 Feeds gege deeg Re 9 Guardian Product Return EE 10 Figure 1 Overall Dimensions essere eee eee eee 4 Fig re 2 Installation ea RE ASEAINENA Aie treaties 4 Figure 3 Setting Tone Pulse Operation 6 Package Contents 1 EP600 Telephone 1 Installation amp Operation Manual Page 2 Guardian Telecom Inc Installation and Operation Model EP600 Overview Hazardous Area Telephone The EP600 Telephone is designed to provide safe reliable communication in Class 1 Division 2 hazardous locations The unit is housed in a rugged weather and corrosion resistant enclosure that ensures operation in severe conditions Features Enclo
4. Inc Installation and Operation Model EP600 Notes Model No Part No Serial No Date of Purchase Page 11 Cio 9001 Guardian Telecom Inc 7552 10th Street N E Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Industrial Communications Worldwide Guardian Telecom Inc 2004
5. UIDE FOR INSTALLATION MADE IN d r CANADA CAUTION KEEP COVER TIGHT WHILE CIRCUITS ARE LIVE FIELD REPAIR NOT POSSIBLE ATTENTION GARDER LE COUVERCLE BIEN FERME TANT QUE LES CIRCUITS SONT SOUS TENSION CET APPAREIL NE PEUT ETRE REPARE A PIED D OEUVRE Figure 4 LD and Compliance Style 12 only Page 8 Guardian Telecom Inc Installation and Operation Model EP600 Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year Guardian Telecom will repair or replace any defective unit that is under warranty This warranty is null and void if any non authorized modifications have been made to this product or if it has been subjected to misuse neglect or accident This warranty covers bench repairs only such repairs must be made at Guardian Telecom or an authorized service depot Guardian Telecom is not responsible for costs incurred for on site service calls freight or brokerage A return authorization must be obtained prior to warranty claims or repairs Disclaimer The products covered by this manual are designed for use in Industrial Environments and or Hazardous Locations Due to the range of possible applications for these instruments the manufacturer will not be responsible for damages or losses of any kind suffered as a result of the use of this product including consequential damages Warning For the purposes of installing the product and repl
6. acing fuses this device may be opened and reassembled by qualified personnel following the instructions in the product manual In the cases of explosion proof and hazardous area devices it is imperative that mating surfaces be clean and undamaged prior to reassembly and that fasteners be made up to the specified torque High voltages may be present in this device when connected to telephone wiring Service Telephone Number 1 800 363 8010 Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone number between regular business hours 8 00AM 5 00PM Mountain Standard Time If you are calling outside of regular business hours please leave a detailed message and a member of Guardian Telecom s Service Department will return your call as soon as possible If your product requires service Guardian personnel will supply you with an RMA return materials authorization number over the telephone or through our web site product return page This number must be included with your return address and the name of the person to contact Guardian Telecom Inc 7552 10th Street N E Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com Feedback Guardian Telecom continually strives to make reliable durable and easy to use products If you
7. as an installer or user of our equipment have any suggestions for improvements to this or any of our products or documents including this manual we would appreciate hearing from you Page 9 Guardian Telecom Inc Installation and Operation Model EP600 Guardian Product Return Guardian products have been quality tested and are in full working order when shipped from the factory given the rugged nature of these products shipping is not expected to damage a unit In the unlikely event of a malfunction Guardian follows the three step procedure below Step On Site Correction e The most common source of difficulties with a new product is improper installation in one of two ways incorrect wiring connections or connection to an incorrect power source e Product wiring needs to be properly connected to the on site wiring Correct wiring instructions are shown in the user manual included with the product e Connecting a telephone to a standard power source rather than tip amp ring will blow the telephone s internal user replaceable fuse In the event of fuse burn out disconnect the telephone from the power source replace the fuse and reconnect following the wiring diagrams provided with the product Step Il Return Materials Authorization RMA e When a product has been installed following user manual instructions and the unit fails to operate the user must contact Guardian Telecom to obtain au
8. o personnel or damage to property The EP600 is set to tone dialing when shipped If pulse dialing is required See Setting Tone Pulse see the section on Setting Tone Pulse Operation Operation Follow all appropriate electrical codes and use only approved electrical fittings for the installation Choose a wall location that is free of obstructions and permits space for 1 2 See EP600 Drawing NPT conduit runs Figure 1 Overall i Dimensions Ensure mounting can support 5 Ibs 2 3 kgs and any foreseeable additional load Ensure that none of the electrical connection circuits are live Use the template provided or the stainless steel mounting bracket to locate See EP600 Drawing and drill holes for mounting screws GC 1 Overall imensions Secure the unit to the wall Tip Use 8 or M4 screws to secure the unit Open the door and remove the four 8 Philips drive screws on the access to the wall plate Connect an approved earth ground to the center post of the surge arrestor Connect the wires from the PABX or CO to the tip and ring connections on See Figure 2 the surge arrestor The unit is not polarity sensitive Installation Ensure all connections are tight then replace the access plate and secure with the four 8 Philips drive screws Apply power to the system Test the unit by calling from another unit on the exchange Maintenance Declassify the hazardous location before proceeding with any
9. sure e weather tight rugged Valox amp steel e spring loaded hinged door e stainless steel mounting bracket Keypad e standard 3 x 4 matrix Magnetic Reed Hook Switch e no moving parts Surge Arrestor e prevents damage to the electronic circuitry in the event of a high voltage spike on the telephone line Wall Mount e easily mounted on any sturdy vertical structure Noise Reducing Microphone e allows a high level of intelligibility in locations with high background noise Tone DTMF Operation e factory set to tone DTMF dialing e canbe ordered set for pulse dialing or configured in the field Heavy Duty Handset Cord e withstands severe use Hearing Aid Compatible e compatible with inductively coupled hearing aid devices Page 3 Guardian Telecom Inc Installation and Operation Model EP600 9 7 246mm a 8 8 224mm BR 12 0 305mm 11 8 300mm 14 0 356mm AH 5 5 E 1 4 Fa ed sl 2 9 74mm 3 8 97mm 3 9 99mm La La Le Figure 1 Overall Dimensions 6 0 152mm 13 0 330mm GROUND GREEN TIP amp RING CONNECTIONS Figure 2 Installation Page 4 Guardian Telecom Inc Installation and Operation Model EP600 Installing the EP600 Declassify the hazardous location before proceeding with any Caution Installation or installation or electrical wiring a a Ge or could result in serious injury t
10. the unit by calling to and from another unit on the exchange TONE PULSE JUMPER HS RINGER HK gt TIP SPARE RING SPARE Figure 3 Setting Tone Pulse Operation Page 6 Guardian Telecom Inc Model EP600 Installation and Operation Engineering Specifications Electrical Performance AUDIBLE RANGE FREQUENCY RESPONSE 300 3400 Hz DIALING METHOD DTMF TONE or 40 60 PULSE AT 10 PPS TRANSMIT OBJECTIVE LOUDNESS RATING TOLR 40 3 dB RECEIVE OBJECTIVE LOUDNESS RATING ROLR 47 3 dB SIDE TONE OBJECTIVE LOUDNESS RATING SOLR 10 4 dB RINGER OUTPUT 75 dB Maximum FCC RINGER EQUIVALENCE NUMBER REN 0 7 B mechanical bell SET IMPEDANCE 600 OHMS NOMINAL MAXIMUM LOOP 15 KFt 4 6 Km Electrical Requirements RINGER SENSITIVITY 40 100 V 16 25 Hz LINE VOLTAGE 24 56 VDC LOOP CURRENT 20 120 MA CONNECTION METHOD SURGE ARRESTOR Environmental WEATHER AND CORROSION RESISTANT ENCLOSURE 3R TEMPERATURE 40 To 60 C 40 To 140 F HUMIDITY 0 TO 95 RH DUST RESISTANT CLASS I HAZARDOUS LOCATIONS Mechanical HOOK SWITCH CRADLE SWITCH LIFE gt 1 000 000 OPERATIONS BODY CONSTRUCTION GE VALOX 357 ENGINEERING POLYMER FACEPLATE STAINLESS STEEL DIMENSIONS H x W x D 14 X 9 7 X 3 9 INCHES 356 x 246 x 99 MM NET WEIGHT 5 LBS 2 3 KG HANDSET MATERIAL HIGH IMPACT ABS
11. thorization to return the product This can be done by done by completing a RMA form online at www guardiantelecom com or by calling the service telephone number given in this manual e After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product s In addition to the RMA number shipping documents should include name address and telephone number of the owner along with contact information for the person responsible for the repair and or the user who identified the malfunction e Where a product is being returned for repair from outside of Canada customs documentation must show the product s serial number date of export date of purchase and a notation that the equipment is Canadian goods returning Step Ill Factory Authorized Service e Once received each product is carefully inspected and tested If the product is under warranty repairs are completed and the product returned to the owner generally within five working days of receipt by the factory e A product that has been subjected to misuse neglect or accident or is beyond the warranty period will be evaluated The service department will provide the owner s representative with a repair cost estimate Once approved repairs are completed and the product returned generally within five working days Page 10 Guardian Telecom
Download Pdf Manuals
Related Search
Related Contents
HomeSelects 7607 Instructions / Assembly 取扱説明書 お客さまへ Nikon 35mm Scanner User Manual ダウンロード - エレクトロラックス ボッシュ 電動工具 メジャーリングツール 受光器 LR2 shRNA expression Cloning Kit Industrial & Electronic Troubleshooting www.rpc.ca 12 meses StarTech.com 3m Multimode 62.5/125 Duplex Fiber Patch Cable LC - LC Copyright © All rights reserved.