Home
PCI9008 User`s Manual
Contents
1. AII3 AII3 AI15 Al15 ATR AGND DGND DTR DGND DGND DGND DGND DGND V6 012 PCI9008Synchronic Data Acquisition V6 012 AGND cc Analog ground This AGND pin should be connected to the system s AGND plane DGND Digital ground Ground reference for Digital circuitry Analog trigger signal input choose AGND as reference ground Digital trigger signal input choose DGND as reference ground PCI9008Synchronic Data Acquisition V6 012 Chapter 4 Connection Ways for Each Signal 4 1 Analog Signal Connection Double ended input mode which was also called differential input mode uses positive and negative channels to input a signal This mode is mostly used when biggish interference happens and the channel numbers are few According to the diagram below PCI9008board can be connected as analog voltage double ended input mode which can effectively suppress common mode interference signal to improve the accuracy of acquisition Positive side of the 8 channel analog input signal is connected to AI0 AI15 the negative side of the analog input signal is connected to AI0 AI15 equipments in industrial sites share the AGND with PCI90080ard Al0 analog signal evice AIO oF Ali device Al1 J Al15 tk C devi AI5 device AGND li e 4 2 Synchronous Trigger Pulse Signal Connection 4 2 1 Synchronous Trigger Pulse Signal Input Conne
2. HaC lock penal MIN e ON NE E o momo m 10 4A TiO Ger Sie tal Betts eR NND uem 10 4 5 Multiple Instrument Synchronization 2400040004000000000000000cee0eseeesesesseseseesssssescsssesseeeceeneeeseenseeneeeeneess 11 Chapter 5 The Instruction of the AD Trigger Function ccccccccccccce ene eeeseecceeeca ae eeeeeeceeeeaeeeeeeeeeeeeaaaeseeeeeeeeaaaaseeeeeeeeaaaaees 13 SN IBN an Msg v RR T 13 LADT emal TEE MOIE oassascessun dubita pt e Rb ttt p DR mb Sn EUNDI e RESI ae ee eee eee 13 SPAN e Eae LES B PI RE RET 13 S DER TA RN 14 Chapter 6 Methods of using AD Internal and External Clock Function eese eene nennen eene 16 SN Tinterinal Clock drei AD HR 16 62 External lock Function o AD penne 16 Chapter 7 Notes Calibration and Warranty Policy essen enhn nhnnn nennen ees esses esi rrr r nnn nennen nnns 17 anc Y 17 A2 AUIOScaliDE TIPO eoe omm E UEM MEMMIUS 17 1 5 M AMAIA OF POLCV aa EEE dq seatie ec mdp MINIMA MS MSIE M MU Gor i cess Gr dL couscous dou 17 Products Rapid Installation and Self check esses nnn nhhn n a i a a a a aiia aaa nana aaa 19 IS351d Ihasta ELO eooauncodenauseteudunestesdesettuxdisesieadesxedaduRw sd caducu Mc cUe ee peu eU etu IAE peu D e cU HEU SR pUMA DC E AD dM Di AD
3. 7 Notes Calibration and Warranty Policy 7 1 Notes In our products packing user can find a user manual a PCI9008 module and a quality guarantee card Users must keep quality guarantee card carefully if the products have some problems and need repairing please send products together with quality guarantee card to ART we will provide good after sale service and solve the problem as quickly as we can When using PCI9008 in order to prevent the IC chip from electrostatic harm please do not touch IC chip in the front panel of PCI9008 module 7 2 Auto calibration By using the auto calibration feature of the PCI9008 the calibration software can measure and correct almost all the calibration errors without any external signal connections reference voltages or measurement de vices Automatic calibration is complete the calibration constants are stored in EEPROM The default calibration constants are stored in fixed storage area Time and temperature will affect the error so when install PCI9008 in the new environment we should recalibrate it NOTE 1 Before auto calibration procedure starts it is recommended to warn up the card for at least 15 minutes 2 Please remove the cable before an auto calibration procedure is initiated because the calibration factor outputs would be changed in the process of the calibration 7 3 Warranty Policy Thank you for choosing ART To understand your rights and enjoy all the after sales ser
4. AD will immediately access to the conversion process and its follow up changes have no effect on AD acquisition This function can be used in the case that the acquisition will occur if the exoteric signal changes PCI9008Synchronic Data Acquisition V6 012 Chapter 6 Methods of using AD Internal and External Clock Function 6 1 Internal Clock Function of AD Internal Clock Function refers to the clock signals which are produced by on board clock oscillator through logic control circuit according to user specified sub frequency to trigger the AD conversion regularly To use the clock function the hardware parameters ADPara ClockSource PCI9008 CLOCKSRC IN should be installed in the software The frequency of the clock in the software depends on the hardware parameters ADPara Frequency For example if Frequency 100000 that means AD work frequency is 100000Hz that is 100 KHz 10 us point 6 2 External Clock Function of AD External Clock Function refers to the use of the external clock signals to trigger the AD conversion regularly The clock signals are provide by the IN pin The external clock can be provided by clock frequency generators and so on To use the external clock function the hardware parameters ADPara ClockSource PCI9008 CLOCKSRC OUT should be set in the software In continuous acquisition mode the frequency of the AD converter is the external clock frequency PCI9008Synchronic Data Acquisition V6 012 Chapter
5. PCI9008Synchronic Data Acquisition V6 012 PCI9008 User s Manual 9 Beijing ART Technology Development Co Ltd PCI9008Synchronic Data Acquisition V6 012 Contents Guo m X 2 CAT OET E A E A E A 3 Chapter 2 Components Layout Diagram and a Brief Description eee eene eene nnne nennen nnne essen 5 2 1 The Main Component Layout Diagram cccccscsscececececeeccccecceceececeeeececeaeaeeecaeaaceceeeeeeeeeeeeeeeeeeaaaaaaaaaaaaas 3 2 2 Signal Input and Output Connector cceeecssesessssessssssssssssssssssssseceeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeaeaaaaaaaeaaaaaaaaaaaaaaaaas 5 Loy Physical IDo DIP Swe iar ESN 5 TA SO OT E E E E E E E E ee eee ee 6 D SIC OCI RET 7 3 1 The Definition of Signal Input and Output Connectors ssssssssse Inns 7 Chapter 4 Connection Ways for Each Signal sssssssssssseseeeeeeeeeeee eene eese nnnennn nnn rrr nnn nnnn eese ess ssssssss i i irr r rne n nnne nns 9 AN E erzira eui RIOT A seen ee ne a ee ere en eee ee 9 4 2 Synchronous Trigger Pulse Signal Connection uei ee ete oe is coacto ec aa aute es ceo ie ea e rE Ee EEE EE EEE Ee EEE EE EEE Ea Ei 9 4 2 1 Synchronous Trigger Pulse Signal Input Connection sse eene 9 4 2 2 Synchronous Trigger Pulse Signal Output Connection cccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 10
6. U M A UD S C ADEM E UE 19 yell elTe 6 ERR EN RON N TNR RR 19 Dclete WEomnp InstallatfOE usn ats spss straw ee apse ei ei usus natio caesi dcs ss LUE LE qe ELI ce LUUD Ted optus Solon UL De SUD oso 19 PCI9008Synchronic Data Acquisition V6 012 Chapter I Overview In the fields of Real time Signal Processing Digital Image Processing and others high speed and high precision data acquisition modules are demanded ART PCI9008data acquisition module which brings in advantages of similar products that produced in china and other countries is convenient for use high cost and stable performance Unpacking Checklist Check the shipping carton for any damage If the shipping carton and contents are damaged notify the local dealer or sales for a replacement Retain the shipping carton and packing material for inspection by the dealer Check for the following items in the package If there are any missing items contact your local dealer or sales PCI9008Data Acquisition Board ART Disk a user s manual pdf b drive c catalog Warranty Card FEATURES Analog Input gt Converter Type AD7865 gt Input Range 10V default x5V AD7865 1 or 0 5V 0 2 5V AD 7865 2 4 bit resolution Sampling Rate 3Hz 80KHz ch Note each channel actual sampling rate sampling rate Frequency division formula master frequency the number of frequency division the master frequency 20MHz 32 bit frequency division and the numbe
7. ction IN Synchronous Pulse Signal PCI9008Synchronic Data Acquisition V6 012 4 2 2 Synchronous Trigger Pulse Signal Output Connection OUT Synchronous pulse signal 4 3 Clock Signal Connection r pa OUT external clock output qu IN external clock input rdi DGND 4 4 Trigger Signal Connection PCI9008Synchronic Data Acquisition V6 012 4 5 Multiple Instrument Synchronization Three methods can realize the synchronization for the PCI8502 the first method is using the Master slave card cascade the second one is using the common external trigger and the last one is using the common external clock When using master slave cascade card programs the master card and slave card use the same TRG signal general the master card uses internal clock source the slave card uses external clock source after the master card and slave card are initialized first start the all slave cards because the main card has not been started so there is no output clock signal then the slave cards into a wait state until the master card is activated at this time all slave cards are started Then we achieve synchronization data acquisition See the following figure IN Slave Card i Slave Card When using the common external trigger please make sure all parameters of different PCI9008 are the same At first configure hardware parameters and use analog or digital sig
8. he initialization if the AD hardware parameter ADPara TriggerMode PCI9008 TRIGMODE SOFT we can achieve the internal trigger acquisition In this function when calling the StartDeviceProAD function it will generate AD start pulse AD immediately access to the conversion process and not wait for the conditions of any other external hardware It also can be interpreted as the software trigger As for the specific process please see the figure below the cycle of the AD work pulse is decided by the sampling frequency AD Start Pulse EM qesememee ese eost eeu The first working pulse after the AD start pulse FigureS5 1 Internal Trigger Mode fessosesssoscososssoscssoscesscscccccseccseseoseccscost 5 2 AD External Trigger Mode When AD is in the initialization if the AD hardware parameter ADPara TriggerMode PCI9008 TRIGMODE POST we can achieve the external trigger acquisition In this function when calling the StartDeviceProAD function AD will not immediately access to the conversion process but wait for the external trigger source signals accord with the condition then start converting the data It also can be interpreted as the hardware trigger Trigger source includes the DTR Digital Trigger Source and ATR Analog Trigger Source 5 2 1 Signal ATR Trigger The analog trigger uses a signal ATR change within a certain range of the analog signal as trigger source This signal input by the ATR pin of the CNI The trigge
9. mmediately access to the conversion process and its follow up changes have no effect on AD acquisition This function can be used in the case that the acquisition will occur if the exoteric signal changes 5 2 2 DTR Trigger When ADPara TriggerDir PCI9008 TRIGDIR NEGATIVE choose the trigger mode as the falling edge trigger That is when the DTR trigger signal is on the falling edge AD will immediately access to the conversion process and its follow up changes have no effect on AD acquisition BUY ONLINE at art control com englishs or CALL 86 10 62991792 609 CN 14 PCI9008Synchronic Data Acquisition V6 012 AD Start Pulse Digital Trigger Signal eescosesss sese os o teu oo es The falling edge before The waiting time gt The first falling edge after the the AD started is I i AD started is valid RAO rns invalid f essssscccscccscscscsesessscsescscsecccceccccceccccceccccseccct il c E i The fist working Figure5 4 Falling edge Trigger When ADPara TriggerDir PCI9008 TRIGDIR POSITIVE choose the trigger mode as rising edge trigger That is when the DTR trigger signal 1s on the rising edge AD will immediately access to the conversion process and its follow up changes have no effect on AD acquisition When ADPara TriggerDir PCI9008 TRIGDIR POSIT NEGAT choose the trigger mode as rising or falling edge trigger That is when the DTR trigger signal is on the rising or falling edge
10. nal triggering ATR or DTR then connect the signal that will be sampled by PCI9008 input triggering signal from ART pin or DTR pin then click Start Sampling button at this time PCI9008 does not sample any signal but waits for external trigger signal When each module is waiting for external trigger signal use the common external trigger signal to startup modules at last we can realize synchronization data acquisition in this way See the following figure External Trigger Signal ART DTR PCI9008 ATR DTR ATR DTR 1 PCI9008Synchronic Data Acquisition V6 012 When using the common external clock trigger please make sure all parameters of different PCI9008 are the same At first configure hardware parameters and use external clock then connect the signal that will be sampled by PCI9008 then click Start Sampling button at this time PCI9008 does not sample any signal but wait for external clock signal When each module is waiting for external clock signal use the common external clock signal to startup modules at last we realize synchronization data acquisition in this way See the following figure mel PCI9008 PCI9008 TM e PCI9008 NN o ERE BUY ONLINE at art control com englishs or CALL 86 10 62991792 609 CN 12 PCI9008Synchronic Data Acquisition V6 012 Chapter 5 The Instruction of the AD Trigger Function 5 1 AD Internal Trigger Mode When AD is in t
11. nd or damaged serial numbers are not entitled to our service 4 Customers are responsible for shipping costs to transport damaged products to our company or sales office 5 To ensure the speed and quality of product repair please download an RMA application form from our company website PCI9008Synchronic Data Acquisition V6 012 Products Rapid Installation and Self check Rapid Installation Product driven procedure is the operating system adaptive installation mode After inserting the disc you can select the appropriate board type on the pop up interface click the button driver installation or select CD ROM drive in Resource Explorer locate the product catalog and enter into the APP folder and implement Setup exe file After the installation pop up CD ROM shut off your computer insert the PCI card If it is a USB product it can be directly inserted into the device When the system prompts that it finds a new hardware you do not specify a drive path the operating system can automatically look up it from the system directory and then you can complete the installation Self check At this moment there should be installation information of the installed device in the Device Manager when the device does not work you can check this item Open Start gt Programs gt ART Demonstration Monitoring and Control System gt Corresponding Board gt Advanced Testing Presentation System the program is a standard testing pr
12. nd the same system at the same time please use the physical ID as much as possible ID3 ID2 IDI IDO 4 3 2 1 ON The above chart shows 1111 so it means that the physical ID is 15 ID3 ID2 IDI IDO 4 3 2 1 ON The above chart shows 0111 so it means that the physical ID is 7 ID3 ID2 IDI IDO 4 3 2 l ON The above chart shows 0101 so it means that the physical ID is 5 2 4 Status indicator TRIG trigger status indicator PCI overflow indicator ADC AD work status indicator PWR power supply indicator BUY ONLINE at art control com englishs or CALL 86 10 62991792 609 CN 6 PCI9008Synchronic Data Acquisition Chapter 3 Signal Connectors 3 1 The Definition of Signal Input and Output Connectors CNI 50 pin D type definition Pin definition about AD AI0 AI15 16 ch analog input positive port ATO AIQ AI2 AI2 Al4 Al4 AI6 Al6 AI8 AI8 AI10 ATIO AI12 ATII2 All4 Al14 AGND AGND DGND DGND DGND DGND DGND DGND DGND 50 49 as a 6 asd sa a3 a af 40 38 x 36 5 34 33 32 a 30 29 28 27 26 N TN IN w A tA N TN N IF Im Tro O fe ro TW TBR CA Os IAN oOo Jo o N C9 43 CA IA CO oO AI0 AI15 16 ch analog input negative port All AIl AI3 AI3 AI5 AI5 AI7 Al7 AI9 AI9 All1 All 1
13. ocedure Based on the specification of Pin definition connect the signal acquisition data and test whether AD is normal or not Connect the input pins to the corresponding output pins and use the testing procedure to test whether the switch 1s normal or not Delete Wrong Installation When you select the wrong drive or viruses lead to driver error you can carry out the following operations In Resource Explorer open CD ROM drive run Others gt SUPPORT gt PCI bat procedures and delete the hardware information that relevant to our boards and then carry out the process of section I all over again we can complete the new installation
14. r of frequency division from 25 to 6666666 Input Channels 16 synchronous inputs Analog Input Mode differential input Channel Switching Mode 16 channel 4 chip to work independently sample Method synchronous acquisition Data Read Mode non empty half full inquire interrupt and DMA mode Memory Size 8K word point FIFO Memory Flag full non empty half full Clock Source internal clock and external clock The Frequency of the Board Clock the current actual sampling frequency of the AD Trigger Mode software trigger hardware trigger external trigger Trigger Type level trigger edge trigger Trigger Direction negative positive either positive or negative trigger Trigger Source ATR analog trigger and DTR digital trigger ATR Input Range 0 10V DTR Input Range standard TTL level VV VV VV V VV VV VV VV V U PCI9008Synchronic Data Acquisition V6 012 Y Auto calibration Programmable Gain 1 2 4 8 times AD8251 default or 1 2 5 10 times AD8250 or 1 10 100 1000 times AD8253 AD Conversion Time lt 2 4Us v Analog Input Impedance 10MQ System Measurement Accuracy 0 05 Non linear error 1 LSB Maximum Operating Temperature Range 0 C 50 C VV VV V WV Storage Temperature Range 20 C 70 C Other Features Board Clock Oscillation 40MHz Dimension 152 1mm L 107 8mm w o BUY ONLINE at art control com englishs or CALL 86 10 62991792 609 CN 4 PCI9008Synchronic Data Acq
15. r signal and the analog trigger level enter the comparator at the same time then they do high speed comparator to produce the expected result Result to trigger the AD to convert see below The effective range of the analog trigger source signal is 0 10V PCI9008Synchronic Data Acquisition V6 012 Result Comparer Trigger Level Figure 5 2 Analog compare When ADPara TriggerDir PCI9008 TRIGDIR NEGATIVE choose the trigger mode as the falling edge trigger That is when the ATR trigger signal is on the falling edge AD will immediately access to the conversion process and its follow up changes have no effect on AD acquisition AD Start Pulse The first working pulse AD Working Pulse i after triggered e UH m ATR emen E p The waiting time m kc i c The falling edge 2 The first falling edge after the before the AD started AD started is valid er NET TEE RC Tea on Figure 5 3 Falling edge Trigger When ADPara TriggerDir PCI9008 TRIGDIR POSITIVE choose the trigger mode as rising edge trigger That is when the ATR trigger signal is on the rising edge AD will immediately access to the conversion process and its follow up changes have no effect on AD acquisition When ADPara TriggerDir PCI9008 TRIGDIR POSIT NEGAT choose the trigger mode as rising or falling edge trigger That is when the ATR trigger signal is on the rising or falling edge AD will i
16. uisition V6 012 Chapter 2 Components Layout Diagram and a Brief Description 2 1 The Main Component Layout Diagram ae MER ir l Ty Lini LANGA ELAS TIME E III i 3 CNI ET u 18 i Maia T9008 veo Man OUTS CWA 2 2 Signal Input and Output Connector CNI signal input and output port IN synchronization pulse signal input port OUTI OUT2 OUT3 sync pulse signal output port 2 3 Physical ID of DIP Switch DIDI Set physical ID number When the PC is installed more than one PCI9008 you can use the DIP switch to set a physical ID number for each board which makes it very convenient for users to distinguish and visit each board in the progress of the hardware configuration and software programming The following four place numbers are expressed by the binary system When DIP switch points to ON that means 1 and when it points to the other side that means BUY ONLINE at art control com englishs or CALL 486 10 62991792 609 CN 5 PCI9008Synchronic Data Acquisition V6 012 0 As they are shown in the following diagrams place ID3 is the high bit IDO is the low bit and the black part in the diagram represents the location of the switch Test software of the company often uses the logic ID management equipments and at this moment the physical ID DIP switch is invalid If you want to use more than one kind of the equipments in one a
17. vices we offer please read the following carefully 1 Before using ART s products please read the user manual and follow the instructions exactly When sending in damaged products for repair please attach an RMA application form which can be downloaded from www art control com 2 All ART products come with a limited two year warranty gt The warranty period starts on the day the product is shipped from ART s factory gt For products containing storage devices hard drives flash cards etc please back up your data before sending them for repair ART is not responsible for any loss of data gt Please ensure the use of properly licensed software with our systems ART does not condone the use of pirated software and will not service systems using such software ART will not be held legally responsible for products shipped with unlicensed software installed by the user BUY ONLINE at art control com englishs or CALL 86 10 62991792 609 CN 17 PCI9008Synchronic Data Acquisition V6 012 3 Our repair service is not covered by ART s guarantee in the following situations Damage caused by not following instructions in the User s Manual Damage caused by carelessness on the user s part during product transportation Damage caused by unsuitable storage environments 1 e high temperatures high humidity or volatile chemicals VV ON V Damage from improper repair by unauthorized ART technicians gt Products with altered a