Home
Test Tool User Manual
Contents
1. 300 mm FOUP memory Recording time is limited by the remaining available space on the internal flash memory up to 24 hours per recording session The Tool is self contained with a rechargeable nickel metal hydride battery pack The batteries provide continuous Tool operation for approximately 28 hours between recharges A 15VDC Universal 110 220 VAC Power Source plugs into the Tool s Control Panel to recharge the battery pack A lithium battery provides battery backup for calibration values and the built in real time clock Figure 2 Vib Tool packaged for Reticle Pod Get Control Accelerometer Test Tool Version 5 0 2 Operation The Control Panel provides the Vib Tool s user interface The operator selects various options from the Tool s menus to setup and perform acquisition 2 1 Control Panel The Test Tool s Control Panel is visible on the top of the unit It consists of an anodized aluminum panel that contains a 16 character by two line LCD a 4 key membrane keypad a power entry plug and a 9 pin DB 9 RS 232 connector The LCD provides display of the Tool s menus The Up Down and Enter keys allow the operator to page through the menus and select from the various options within the menus The On Off switch toggles power to the Tool The RS 232 connector provides the communications interface for uploading recorded data files to the PC via the GCI VibPlot Application The power entry plug is used to charge the inte
2. of time domain data recorded RECORDED 00 10 32 Press the ENTER key to clear this message and return to the Main Menu Get Control Accelerometer Test Tool Version 5 0 2 2 4 Connect VibPlot Menu Press ENTER at the MAIN MENU CONNECT VIBPLOT message to prepare the Vib Tool for uploading the data file to the PC using the VibPlot Application The Vib Tool displays the USE VIBPLOT MENU ENTER TO ABORT message Connect the Vib Tool s communications port connector female DB 9 to an available PC COM port using a straight through 9 pin male to female communications cable provided Launch the VibPlot Application and use the Connect to Vib Tool dialog box to upload recorded data files See the separate document VibPlot Users Guide for details on the VibPlot Application Before the connection is initiated press the ENTER key to abort and return to the Main Menu Once a connection with the PC is made it must be terminated from the PC it cannot be aborted using the Vib Tool s menu keys After connecting with the VibPlot Application the Vib Tool displays CONNECTED TO VIBPLOT message The Vib Tool will automatically return to the Main Menu when it is disconnected from the PC using the Connect To Vib Tool dialog box Disconnect button 2 2 5 Calibration Menu Press the Enter key at the Main Menu Calibration option to advance to the Display Calibration Menu The Calibration menu provides verification of the Tool s operation and a meth
3. the PC for analysis Each file is uniquely named and contains header information detailing the time and date recording was initiated along with the Test Tool s S N and firmware version information 4 Software 4 14 Data Acquisition The Vib Tool simultaneously samples each of the vibration data channels at a uniform rate of 512 samples per second 4 2 Data Recording The Vib Tool continuously streams time domain data to internal flash memory The Vib Tool stores the initial start time and date and begins recording data points at a uniform rate of 512 points per second on each channel Data recording continues until the onboard flash memory fills up to 24 hours per recording session or the user presses the Enter key Note that the time and date of recording is based on the Vib Tool s internal real time clock Ensure that the time and data are properly set before initiating a recording session 4 3 Data Reduction Data reduction of the recorded time domain data is handled by the VibPlot Application running on a PC Use the VibPlot Application to upload the recorded data files to the PC for analysis Please see the separate document VibPlot Users Guide for additional details on available data reduction options Get Control Accelerometer Test Tool Version 5 0 4 4 Data Retrieval The Vib Tool supports data uploading to a Host PC via a standard RS 232 communications port Using the VibPlot Application the user connects to the Vib Tool a
4. to the accelerometer data sheet specifications provided with your tool default nominal is 2 500 V offset and 1000 mV g sensitivity These coefficients are stored in battery backed RAM For this verification it is not critical that they exactly match the data sheets but they must be reasonable numbers close to default nominal for the Calibration Display feature to operate properly If the battery backed RAM corrupts where the Calibration Coefficients are stored the tool firmware detects this and resets them to default nominal Refer to the User s Guide for instructions to perform this verification Using the Calibration Display menu we orient each axis of the test tool perpendicular to earth gravity and verify its ability to sense this 1g constant This function is only used for the purpose of verifying test tool operation It is not used for calibration and the test tool does not record earth gravity during normal operation Several factors affect this measurement including The test tool circuits contain DC offsets that make this reading accurate to 10 Earth gravity is slightly dependant on geographic location It is difficult to hold the tool exactly perpendicular to the earth without a leveling mechanism Orient the tool so that its front is facing up the positive X axis is parallel to earth gravity as shown in Figure 6 Verify that the tool reads 1 00g 0 10 Figure 6 X Axis Positive Figure 7 X Axis Negative Orient t
5. 0mm mounting plate use the included 1 hex head screws washers and springs as detailed on page 11 of this manual When using the Tool with 300mm mounting plates please note that the axes have been rotated The data recorded will still be reported as X Y and Z Axis data but the Y Axis will be the vertical axis Remove Screws Replace with 300 mm Mounting Plat hardward Remove Screws Replace with 300 mm Mounting Plat hardward Accelerometer Test Tool Side View Figure 4 300mm Plate Mounting Holes Get Control Accelerometer Test Tool Version 5 0 Figure 5 shows details on attaching the 300 mm Mounting Plates to the Vib Tool The bottom plate is fastened directly to the enclosure The top plate is mounted with springs between the enclosure and plate The top screws are left loose to allow the unit to align with wafer slots in the FOUP Once the unit is place into a FOUP the hex head or hex socket screws are tightened down using a 3 16 socket or hex wrench to firmly grip the slot fingers Tighten the screws such that the Vib Tool is secure to the FOUP Over tightening may damage the FOUP and or the Vib Tool 300 mm Mounting Plate Washer ETE 1 Long ze Hex Head 4 40 Screw Figure 5 Test Tool with 300 mm Mounting Plate 3 2 Mounting Brackets for 150 mm Reticle Pod Installation When packaged for 150 mm reticle pod installation the Vib Tool is shipped with all required mounting brackets attached Get Con
6. Get Control Accelerometer Test Tool User s Guide Version 5 0 Get Control Accelerometer Test Tool Version 5 0 Table of Contents Intr d cti n a v sark aa re AA 2 2 A 2 A e a a a e E 1 Operation A deer eme tete cett ea te ette tee tte te ete Te tte A al t 2 2 4 GontroliPamel 23 33 tate te hdd bd Fd bd Fd bd Fed bd da An hh ba B ba A a A d 2 2 2 Men SIF GIUFG x ro Reb ak e od bod be od be dos bs ce bs ce cbe ce bs ce bs ice ebd 2 22 1 Numeric Data Entry sensor hf Ep Ep AA 3 2 2 2 Main Menu Startup Screens oooooccccoc eh 3 2 2 8 Main Menu Acquire Data 3 2 2 4 Connect VibPlot Menu 54 xh rich ilimiz 4 22 5 Calibration Mente Rh fh Ry hu fub iub ods ods dd a 4 2 2 5 1 DisplayStaticVibrattonMenu 4 2 2 5 2 Set Accelerometer Coefficients 4 2 29 39 Flash VID cia na vre eed aca o et ra Bad ek pula ee c a bab 5 2 2 5 4 Flash SD Module n a e ta o ae td ot ota t Eu c tu e a de a de t das 5 2 2 6 Recharge Cells Menu 22 2i 2224 Re Rr e e ee ea da dt es 5 2 2 7 Set Time and Date Menu 22 22 92 b AAA 5 Mechanical cocos AA A AAA AA 6 3 1 Mounting Brackets for 300mm FOUP Installation o o oooooooooooooooo 6 3 2 Mounting Bracketsfor150mmtReticlePodinstallaton 7 3 9 GontroliPanel wars tue Rc cc ncc ce a a c va o he o he ho d o
7. ata up to the point of the shutdown will be available after the battery is recharged 2 2 7 Set Time and Date Menu The Set Time and Date option provides the method to set the time and date of the Vib Tool s built in real time clock The Set Time and Date option contains two menus One to enter the date and the other to enter the time Refer to Section 2 2 1 for instructions on numeric entry After entering the Date and Time the Tool returns to the Main Menu The test Tool contains a built in real time clock lt provides a two digit year counter which is Year 2000 compatible The test Tool will maintain the correct time date of the month day of the week month and two digit year with correct leap year compensation up to year 2099 The test Tool provides the year with a two digit counter It does not provide century information Get Control Accelerometer Test Tool Version 5 0 3 Mechanical 3 1 Mounting Brackets for 300mm FOUP Installation When packaged for 300 mm FOUP installation the Vib Tool requires 300mm plates that allow it to be mounted inside the FOUP Standard 300 mm mounting plates can be attached to the Test Tool using the supplied hardware shows the location of the mounting holes for 300 mm plates These mounting holes are on each side of the Vib Tool To attached the bottom 300mm mounting plate use the included 7 16 pan head phillips screws Tighten the plate firmly against one side of the tool To attach the top 30
8. atch those reported by the accelerometer manufacturer A set of coefficients are shipped with each Test Tool documenting the three accelerometers installed Press the Enter key to advance to the X axis Offset and Sensitivity menu Press the Down arrow from the Set Coefficients Calibration Menu to return to the Main Menu The Tool displays one numeric entry menu for each accelerometer for a total of three menus Each menu prompts for the Accelerometer Offset and Sensitivity After setting the three axes coefficients a final menu allows for entry of the voltage and temperature offsets Refer to Section 2 2 1 for instructions on numeric data entry Get Control Accelerometer Test Tool Version 5 0 2 2 5 3 Flash Vib The Vib Tool firmware is field ungradable The Flash Vib menu option allows the user to upgrade the Test Tool firmware with a new version supplied by GCI This menu option should not be used unless a firmware image file has been received from GCI along with instructions on upgrading the firmware 2 2 5 4 Flash SD Module The Vib Tool hardware includes a second processor dedicated to storage management of the internal flash memory The firmware for this second processor is also field ungradable The Flash Logger menu option allows the user to upgrade the Time Domain Module firmware with a new version supplied by GCI This menu option should not be used unless a firmware image file has been received from GCI along with instructions on u
9. d d hd dd 8 3 4 Charge Unit s usd hh ta bxc be A A d Lis 8 3 4 1 Low B dltery Serse osse b e i br b ov dc de A 8 3 5 Ho 292 Cabl6o Ssmus tuu tuu tuu tuu tuu tee ers 8 2 6 Flash Memory NA 8 SIUE P C PPP EE I 8 4 1 Data ACQUISIIION 34 3 aa aa 2a 2 te iu hu fu fe hz e tate hg fe fu Ra da fu fu Ru da fu tu Re tates 8 4 2 Data Recording zensiert do diana dada 8 4 0 Data REGUCION 330 aos Ph Ph Ph Pb Pb Pubs Pub Pub Bb Pob El ala 8 4 4 Dala REIeV EEEE 33 20 20 20 8 aa 38 3098 28 38 3098 28 38 308 28 38 308 28 8 308 28 28 908 28 8 308 8 8 308 8 38 308 28 38 308 28 38 28 lil da 9 Technical SUDDOKLE EET 9 Get Control Accelerometer Test Tool Version 5 0 List of Figures Figure 1 Vib Tool mounted in 300 mm FOUP oooccccccccoo rs 1 Figure2 ViblToolpackagedforReticePod 1 Figure 3 Vib Tool Menu Flowchart hr 2 Figure 4 300mmPlateMountingHoles 6 Figure 5 Test Tool with30oommMountingPlate 7 Figure 6 X Axis POSITIVO osse ee e e EEEE aE e e e 0 da EER ER a a E a a e Gl EG 10 Figure 7 X Axis Negative nennen 10 Figure 8 Y Axis Positive eee 11 Figure 9 Y Axis Negative aussen ae ee AAA AAA qa ia 11 Figure 10 Z Axis POSITIVE iss vu ene XR Bra ran aan Ban Rn rar EARN YARN TASA 11 Figure 11 Z Axis N
10. e Enter key to advance the cursor right one digit When the cursor is on the right most digit of the parameter press Enter to accept the parameter 2 2 2 Main Menu Startup Screens When first powered up a sign on message is displayed showing the tools internal time and date firmware version number and serial number After a two second delay the tool runs through an initialization process During this process the time and date is replaced with the word Initializing This indicates that the tool has successfully booted If the Initializing message is not displayed after several seconds the Vib Tool may not have booted properly Cycle power to retry Part of the inititialization process is a check of available space on the internal flash memory for recorded data The Maximum Recording Time is displayed at the end of the initialization step This message can be used to determine when data files should be removed from internal storage Pressing the ENTER key will clear this message and display the main system menu starting with the Acquire Data option The Main Menu contains six options Acquire Data Connect VibPlot Calibration Recharge Cells and Set Time and Date Use the arrow keys to scroll through the options and press the Enter key to select an option Sections 2 2 3 through 2 2 7 describe the five main menu options and their functions 2 2 3 Main Menu Acquire Data Press the ENTER key at the MAIN MENU ACQUIRE DATA sc
11. egative hr hr 11 Get Control Accelerometer Test Tool Version 5 0 1 Introduction The GCI Accelerometer Test Tool also known as the Vib Tool provides precise measurements of the acceleration that semiconductor wafers and reticles experience during automatic and manual transportation Using three accelerometers mounted in a tri axial configuration the Vib Tool simultaneously acquires and records data on the X Y and Z axis Time domain data is recorded at a rate of 512 Hz 512 samples per second for each axes to internal flash memory Recorded data files can be uploaded to the PC for analysis using the GCI VibPlot Application The Vib Tool provides two packaging options one for use in wafer carriers and FOUPS the other for reticle pods RSP 150 The FOUP packaging option ships with mounting plates to securely mount the tool inside an industry standard 300mm FOUP The reticle packaging option ships with mounting bars to securely mount the tool inside an industry standard 150mm reticle pod The Control Panel provides the Vib Tool s user interface lt consists of a 16 character by two line Liquid Crystal Display LCD and a 4 key membrane keypad The LCD displays the Tool s menus and the keypad provides user control of menu navigation and selection of various options lt also provides a switch to turn the Tool on and off The Vib Tool records data to internal flash Figure 1 Vib Tool mounted in
12. he tool so that its front is facing down the negative X axis is parallel to earth gravity as shown in Figure 7 Verify that the tool reads 1 00g 0 10 10 Get Control Accelerometer Test Tool Version 5 0 Press the Down Key to advance to display the Y Axis Orient the tool so that its right side is facing up the positive Y axis is parallel to earth gravity as shown in Figure 8 Verify that the tool reads 1 00g 0 10 Figure 8 Y Axis Positive Figure 9 Y Axis Negative Orient the tool so that its right side is facing down the negative Y axis is parallel to earth gravity as shown in Figure 9 Verify that the tool reads 1 00g 0 10 Press the Down Key to advance to display the Z Axis Orient the tool so its top is facing up the positive Z axis is parallel to earth gravity as shown in Verify that the tool reads 1 00g 0 10 e E Figure 11 Z Axis Negative gt A Figure 10 Z Axis Positive 4 5 M Orient the tool so that its top is facing down lift the tool over your head the negative Z axis is parallel to earth gravity as shown in Figure 11 Verify that the tool reads 1 00g 0 10 11 Get Control Accelerometer Test Tool Version 5 0 If the tool measures earth gravity to 0 1g 10 using the Calibration Display feature it is working properly To remove the system DC offsets to get a more accurate verification use a level to improve the accuracy of each axis measurement Rec
13. nd requests a list of available data files The user selects the desired file and uploads the data to the PC s hard drive The file can then be opened by the VibPlot Application for data reduction and graphical analysis Please see the separate document VibPlot Users Guide for additional details on the data retrieval process 5 Technical Support If you encounter problems using the Vib Tool Get Control technical support can be reached the following ways By email at support getcontrol com By phone at 1 480 539 0478 9am 5pm Mountain Standard Time Also see our web site at www getcontrol com for additional information about Get Control Inc Get Control Accelerometer Test Tool Version 5 0 6 Operation Verification Application Note This application note shows how to verify operation of the Vib Tool system Using the Calibration Display feature and earth gravity each of the three axis can be verified Turn on the Tool and advance to the Calibration Display menu Press enter and the real time DC component of the X axis vibration is displayed The orientation of each axis is drawn on the keypad newer models or etched into the top of the enclosure older models From the face of the tool positive X points to the front of the tool positive Y points to the right side of the tool and positive Z is down into the tool The orientation of the Z axis is assumed not shown for clarity Verify that the tool s Calibration Coefficients are set
14. od to change each accelerometer s coefficients The factory sets the accelerometer coefficients and it is not necessary to modify them under normal operating conditions They do however need to be modified when replacing an accelerometer 2 2 5 1 Display Static Vibration Menu Press the Enter key at the Display Calibration Menu to display the X Axis vibration level The Tool updates the current X axis vibration approximately two times per second The vibration is displayed as specified by the Analysis Type option acquired data is not recorded in this mode Use the arrow keys to scroll through the three axes From the X axis display press the Down arrow to display the Y axis vibration and the Up arrow to display Z axis vibration Press the Enter key to return to the Main Menu Tool verification is possible by taking advantage of the accelerometer s static acceleration response The accelerometers will report approximately 1 0 g of acceleration when they are parallel to earth gravity Rotating each accelerometer through earth gravity while monitoring the static response will verify correct Tool operation If the reading for any axis varies by more than 10 0 10 g please contact GCI technical support 2 2 5 2 Set Accelerometer Coefficients The Set Accelerometer Coefficients option provides a method to change the accelerometer s factory coefficients This is only necessary when replacing one of the Tool s accelerometers Coefficients must m
15. ord each positive and negative axis reading Then subtract the negative axis measurement from the positive axis measurement and divide this result by 2 This number should be close to 1 00g This method removes the tool s DC offsets from the measurements However it does not account for geographical earth gravity variances or inaccuracies in orienting the tool perpendicular to earth gravity 12
16. pgrading the firmware 2 2 6 Recharge Cells Menu Press the Enter key at the Main Menu Recharge Cells option to recharge the internal nickel metal hydride battery pack The battery pack can be recharged at any time by connecting the supplied 15 VDC Universal 110 220 VAC Power Supply to the Tool During the fast recharge operation the Tool displays a Recharging message along with the battery Voltage and the Temperature measurements The software automatically terminates the fast charging operation if it detects voltage or temperature extremes The 15 VDC Universal Power Supply provides a trickle charge to the battery pack when it is plugged in and connected to the Vib Tool Complete fast charging of the battery pack takes approximately five hours When the charge cycle has completed a Charge Complete message will be displayed Pressthe Enter key to return to the main menu The charge operation may be aborted at any time by pressing the Enter key The Tool will display a low battery warning indicator when it requires charging An Omega 0 appears in the menus when the Tool is not recording data to indicate the low battery condition When the battery level reaches a point that further discharge will damage the battery the Tool automatically shuts itself off During data recording the Tool does not display the low battery warning indicator before it shuts off due to a low battery condition When the Tool shuts itself off during recording all d
17. reen to initiate a recording session The Vib Tool displays a INITIALIZING PLEASE WAIT message while it prepares internal storage to accept the recorded data It then displays a maximum recording time message The system will automatically terminate acquisition when the displayed time expires Alternately the user can terminate recording manually Press the ENTER key to start recording data The Vib Tool writes some header information into the data file including the tool s S N firmware version number and time and date While the header information is being written which takes a few seconds the tool displays the RECORDING WRITING HEADER message When the header has been written the system initiates it s time domain data acquisition module and begins streaming recorded data to the data file The display changes to RECORDING TIME DOMAIN DATA While this message is displayed the system is continuously recording time domain data to internal flash memory To terminate the recording session press the ENTER key The Vib Tool displays several messages while it halts it s acquisition module and closes the recorded data file Do not turn the Vib Tool s power off until the file closing process has completed The tool displays the CLOSING FILE PLEASE WAIT message followed by a file closed message which includes the filename FILE VIB0004 DAT CLOSED Pressing the ENTER key will clear this message and display a message indicating the amount
18. rnal nickel metal hydride battery pack using a 15 VDC wall transformer 2 2 Menu Structure Figure 3 shows a flowchart of the Vib Tool s message sequence Typically the top line of the LCD displays the current menu title or mode The bottom line displays the current option or Tool status Press the Up and Down arrow keys to scroll through the menu options Press the Enter key to select the displayed option System Power Cycle 10 30 09 14 51 INITIALIZING VER 5 0 S N 52 after 2 second delay VER 5 0 S N 52 up MAIN MENU INITIALIZING RECORDING ACQUIRE DATA PLEASE WAIT WRITING HEADER JOWN MAIN MENU m USE VIBPLOT ME t ENTER or RECORDING CONNECT VIBPLOT ENTER TO ABORT pisconnect from TIME DOMAIN DATA DOWN VibPlot VP MAIN MENU CLOSING FILE CALIBRATION PLEASE WAIT D UN VP MAIN MENU RECHARGE MENU FILE VIB0014 DA RECHARGE CELLS BEGIN RECHARGE CLOSED DOWN UP mp MAIN MENU RECORDED SET TIME DATE 01 32 DOWN Figure 3 Vib Tool Menu Flowchart Get Control Accelerometer Test Tool Version 5 0 2 2 1 Numeric Data Entry The test Tool accepts numeric entry using the up and down arrow keys Use numeric entry to set the Accelerometer coefficients and the test Tool s internal date and time When the Tool enters a numeric entry menu the current setting of the menu s parameter appears with the cursor located under the left most digit Use the Up and Down arrow keys to increment or decrement the digit at the cursor Press th
19. trol Accelerometer Test Tool Version 5 0 3 3 Control Panel The Control Panel is located on the top of the main structure The Control Panel consists of a membrane keypad a power entry port and a 9 pin female connector The membrane keypad and connector fasten to the enclosure such that it remains completely enclosed to minimize particulate generation from the Vib Tool s PC board 3 4 Charge Unit A Universal 110 220 VAC 15 VDC Power Supply is used to recharge the internal nickel metal hydride battery pack 3 4 1 Low Battery Sense The Vib Tool continuously monitors the nickle metal hydride battery voltage and reports a low battery warning by displaying an Omega Q symbol on the LCD when not recording data If the battery level falls below an operational level the Vib Tool shuts itself off During recording a warning is not displayed but the Tool will automatically shut off In all cases data is retained regardless of the level of the internal batteries 3 5 RS 232 Cable A standard 9 Pin adapter cable P N 9101 22 030 is used to transfer recorded data to a PC 3 6 Flash Memory The Vib Tool includes 1 GB of flash memory used for recorded data storage The Vib Tool manages the flash memory similar to a standard PC hard drive Each recording session is given it s own data file that is used to store recorded time domain data This allows the user to run multiple separate recording sessions before uploading the recorded data to