Rear Window and CaptiView Display Closed Caption User Manual
Contents
1. Add Delete Device Type Closed Caption x Enabled Setup Identifier Closed Caption Model Field Wgbh Rwc x Subtitle Engine Serial Port Field erial Port dev ttySO z Auditorium 1 Play Offset 0 millisecond Idle Text Idle Time 30 seconds Mirroring On Off Closed Caption Figure 11 Rear Window Caption Configuration Example Click the Save button when finished to save the configuration see Figure 11 above D2K DP 000469 DRM Page 12 Version 1 8 Doremi Cinema LLC 4 Appendix A SB430 10 Set Up Instructions The SB430 10 device is an option for customers who do not have a Doremi Digital Cinema Server but still want to use the CaptiView Device There are two ways to set up the SB430 10 First the Ethernet Port is the primary way to set up the SB430 10 device The secondary way to set up the SB430 10 is to use the Serial Port which is a back up mechanism when the Ethernet Port fails or does not work properly Figure 12 SB430 10 Figure 13 SB430 10 D2K DP 000469 DRM Page 13 Version 1 8 Doremi Cinema LLC 4 1 SB430 10 Ethernet Port Set Up 4 1 1 Remove the SB430 10 from packing and begin to set up near a power outlet and computer that has a free Ethernet port The default IP address of the SB430 10 is 192 168 9 10 Set your computer s IP address in t
2. if the upgrade was successful open an SSH session and type the following command more doremi etc version and make sure that the version matches that of the pkg file 4 4 Changing the Auditorium on the SB430 10 Connect to the SB430 10 via ssh session e Login as username root e Type echo n aud_number gt doremi etc s430 10 audi conf and then press the Enter key Reboot for the changes to take effect D2K DP 000469 DRM Page 16 Version 1 8 Doremi Cinema LLC 5 Acronyms Term Definition DCP Digital Cinema Package USB Universal Serial Bus UUID Universally Unique Identifier RWC Rear Window Caption D2K DP 000469 DRM Page 17 Version 1 8 Doremi Cinema LLC 6 Document Revision History Date Version Description 09 28 2010 1 6 Rear Window Closed Caption section updated Software version updated to reflect version 2 0 0 12 27 2010 1 7 All sections revised New CaptiView Device and SB430 10 pictures added 01 10 2011 1 8 Section 2 2 2 revised D2K DP 000469 DRM Page 18 Doremi Cinema LLC Version 1 8
3. take effect e Connect the CaptiView Transmitter to the USB port on the SB430 10 and go back to Section 2 of this manual to finish the setup D2K DP 000469 DRM Page 15 Version 1 8 Doremi Cinema LLC 4 3 Upgrading the SB430 10 Software There are two ways to upgrade the software on the SB430 10 One way is to use an FTP client e g Core FTP or Filezilla and the other is to use a USB flash drive to perform the upgrade 4 3 1 FTP Client e Make sure that an FTP client is installed on the computer e Turn the SB430 10 ON and make sure it is able to ping to the network e Open the FTP client and connect using the IP of the SB430 10 under port 21 and login as the root user and enter the appropriate password e Add the update package pkg file to the folder doremi etc rc once and then reboot e To check if the upgrade was successful open an SSH session and type the following command more doremi etc version and make sure that the version matches that of the pkg file 4 3 2 USB Flash Update e Create a folder in the USB drive and name it doremi then inside the doremi folder create another folder and name it update For example doremi update e Copy the pkg file to the path of the USB flash doremi update then safely unmount the USB flash drive e Put the USB flash drive in place of the CaptiView transmitter Wait for the light to stop blinking and then do a reboot or power cycle e To check
4. DP 000469 DRM Page 5 Version 1 8 Doremi Cinema LLC Note The Doremi Digital Cinema Servers DCP 2000 DCP 2K4 or ShowVault must have software 2 0 0 0 or higher to support the CaptiView It is recommended to test the CaptiView system to ensure that it operates correctly before using it in a live theater get a Digital Cinema Package and test the CaptiView device upon completion of the set up e Plug the CaptiView transmitter dongle into a Doremi Digital Cinema Server USB port only e Go to Menu and then click Control Panel e Select and open the Device Manager icon Control Panel Doremi Cinema ia Leal Oh Select a program to start XKR Quit Q ia Content Feed Device Diagnostic Language License Manager Manager Tool Setup Manager Live Manager Networking Time Setting TouchScreen Configuration Calibration Start Account Manager menu _ control Pane Figure 4 Control Panel Window e From the Device Manager window click on the Add button e The Add Device window will appear e Select the Closed Caption device D2K DP 000469 DRM Page 6 Version 1 8 Doremi Cinema LLC Add Device _ xX Select a device to add Closed Caption Add Cancel q Figure 5 List of Devices Closed Caption Example e Click the Add button see Figure 5 above e The user will now be back to the Device Manager GUI to finish configuring the device 2 2 2 CaptiView Conf
5. doremi DCP 2000 Digital Cinema Server CaptiView Display Closed Caption and Rear Window User Manual Version 1 8 D2K DP 000469 DRM Version 1 8 Page 1 Doremi Cinema LLC Table of Contents TACO UCUON ETE E A A E E A A 3 T I Pupo Se aaa e a e a a sescivsneeussiderevdeveis vctectesatndaddvied die ciser eacevutssteveresiiees 3 1 2 System ROQUIFCINOIUS viissccsscet nite tnccincnieusesenseasdenavedsdutanaghenidianddessiuaedeosdusntapagideacaliierineass 3 FS COLAC bit asvauatsenisiouscdetaezs vi ansts venlansaawunsiab snes dante E ns anarioyieandadals E 3 2 CaptiView Display Installation ProceCure cccccceeeeeeeeeeeeeeeeeeeeeeeaseeeeeeeeeeeeeeeeeeeeeeeeeeees 4 ZAANTOGUCHOM iui sastasssavaciwsioniscortiaiadriate shave tote eaaa Ea aa aa e e aaae aA a aa ana aiaiai 4 2 2 How to Set Up the CaptiView SYStem 222ccccccccceeeeeeeeeeeenenennnnnnenenenensenennenenseneaneeneneanes 5 2 2 1 Installing the LICCMSC carcass cetectasacaicedesuavensavend gis trenvanei nada aaupisaed aduataabdncerh nennen nnmnnn 5 2 2 2 CaptiView Configuration ccccccseseeeseseeceeeeeeeeeeeeeeeeeeseeeseenseeseeceeeeeeeeeesseeoeaseeeeeeeees 7 2 2 3 Operating the CaptiViewissscccccccscecssceccsssccsscccsssesavescsdeneescedcccncseedscarssesteesesetsnieectesseees 9 3 Rear Window Caption Configuration cccccceeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeaaaaeeeeeeeeeeeeeeeeeeeeeeeeeaaes 12 4 Appendix A SB430 10 Set Up Instructions ccccee
6. eeeeeeeeeeeeeeeeeeeee ene eeeeeeeeeeseeeeeeneneeeeees 13 4 1 SB430 10 Ethernet Port Set Up 2 ccccccceseseseeeeeeneeeeeeeeeeeeeeseneeeeeeaaaannseneeseeseneesennonees 14 4 1 1 Configuring the IP Address for SB430 10 cccccccceeeseeeeeeeeeeeeeeeeeeeeeeeeeseeeaeeees 14 4 1 2 Adding the IP Address of the Digital Cinema Server to the SB430 10 14 4 2 SB430 10 Serial Port Set UD viisssisssscacccssizeciscedeccactsebassesssesadeateissiecssceeacessicetsosseisesievdun s 15 4 2 1 Configuring the IP Address for SB430 10 0 ccccccteeeeeeeeeeeeeeeeeeeeeeeeeeeneeseeeeneees 15 4 2 2 Adding the IP Address of the Digital Cinema Server to the SB430 10 15 4 3 Upgrading the SB430 10 SOPWALE cccccsssececeeeneeenennnennneeaeeeeeeeessesesseseeeensneeeeeneaeennens 16 4 3 1 FUP Clet a i a a Taaa reaa seve a araa aa a ainas Sakma Nana aE eauncuewmdenncetcadendas 16 4 3 2 USB Flash Update adana naaasar inaran e aaeanoa endvanecessetercazeensnuauns 16 4 4 Changing the Auditorium on the SB430 10 csscccccceeeeeenenenneeeeeeeeeeeeeseesseeeeeesseneeeneees 16 SP PACT ON YING aE E E T O duveincruus nnatanintend de dsiteasaline 17 6 Document Revision HiStOLy eeeeeeeeeeeeeeeeeeeeeeeseeeseeceeeeeneeeeeeeeeeeeeeeaeaeeeaeeeeseeeouaeeeeeeeeees 18 D2K DP 000469 DRM Page 2 Version 1 8 Doremi Cinema LLC 1 Introduction 1 1 Purpose This manual explains how to set up the DCP 2000 in order to display Closed Capti
7. he range 192 168 9 xx xx being in the range 2 254 except 10 Connect the SB430 10 with an Ethernet cable to the newly configured port and power ON Download and install the program PuTTY or any ssh client on the computer you just assigned the new IP address to Connect to the default IP 192 168 9 10 on port 22 using the ssh client When the unit is done booting up login as root o Password for root is veeone o It is recommended to change the root password by typing the following command and following the on screen instructions passwd Configuring the IP Address for SB430 10 To configure the IP of the SB430 10 type the following command o echo n xxx xxx xxx xxx gt doremi etc ip_addr xxx xxx xxx xxx the desired IP address and then press the Enter key To configure the netmask type the following command o echo n XXX XXX XXX XXX gt doremi etc netmask and then press the Enter key To configure the gateway type the following command o echo n XXX XXX XXX XXX gt doremi etc gateway and then press the Enter key Adding the IP Address of the Digital Cinema Server to the SB430 10 To add the IP address type the following command o echo n xxx xxx xxx xxx gt doremi etc s430 10 ip conf and then press the Enter key Reboot the SB430 10 for the changes to take effect Connect the CaptiView Transmitter to the USB port on the SB430 10 and then go back to Section 2 of this manual to finish
8. iguration e Check the Enabled box to enable this feature e Itis recommended to leave the default settings as they are except for the Auditorium field e In the Auditorium field choose any other channel than 0 For example choose 1 2 3 etc but do not leave the channel set at 0 The number once saved will be saved to the USB transmitter which then must be power cycled by unplugging and then re plugging the transmitter this applies to software versions 2 0 10 and higher Note To change the current auditorium number if using software versions 2 07 or below contact Doremi Technical Support to receive a hot fix In software version 2 0 10 and higher the user can change the auditorium setting from the Device Manager GUI e Define the Play Offset Idle Text and Idle Time o Play Offset This feature offsets the Closed Captioning data in the form of milliseconds o Idle Text The default text that is shown on the display o Idle Time The time it takes for default Idle Text to appear after loss of input e Click the Save button D2K DP 000469 DRM Page 7 Version 1 8 Doremi Cinema LLC Closed Caption Figure 6 Closed Caption Configuration Window D2K DP 000469 DRM Page 8 Version 1 8 Doremi Cinema LLC 2 2 3 Operating the CaptiView e To turn the CaptiView display ON locate the small switch on the right side of the device and set it to the left see Figure 7 below On Off Swi
9. on using the Doremi CaptiView device This document explains how to set up the DCP 2000 in order to display the Closed Caption using the Rear Window device with Serial or Ethernet Communication In Appendix A there is more information on how to set up the SB430 10 which is a device that allows non Doremi Digital Cinema Servers to interface with the CaptiView device 1 2 System Requirements This manual is for operating the CaptiView device software versions 2 0 0 and higher The Rear Window device can be used on any software versions The SB430 10 device can be used on various software versions which depend on the provisions of the digital server For earlier software versions please see earlier revisions of this document 1 3 Contact If in need of help or assistance please contact Doremi Labs Technical Support at 1 866 484 4004 or email at support doremicinema com D2K DP 000469 DRM Page 3 Version 1 8 Doremi Cinema LLC 2 CaptiView Display Installation Procedure 2 1 Introduction The CaptiView is an in theater closed caption viewing system for the hearing impaired The system is composed of three key elements CaptiView license CaptiView display and Captiview transmitter Figure 1 CaptiView Display e CaptiView Display is a portable LCD screen attached to a flexible arm that fits in any standard cup holder on a theater seat CaptiView 7 DO NOT flip this switch Figure 2 CaptiView Transmitter e Ca
10. ptiView Transmitter is a custom encrypted wireless dongle that is plugged into a USB port on a Doremi Digital Cinema Server Warning DO NOT flip the switch on the Doremi Cinema side of the transmitter see Figure 2 above This will delete the firmware and lead to the device becoming inoperable D2K DP 000469 DRM Page 4 Version 1 8 Doremi Cinema LLC 2 2 How to Set Up the CaptiView System 2 2 1 Installing the License The CaptiView license is required to enable a Doremi Digital Cinema Server to playback the Closed Caption data contained in the Digital Cinema Package DCP The license needs to be installed before setting up the CaptiView system Contact Doremi Technical Support at support doremicinema com to receive the Closed Caption license e Insert the USB with the Closed Caption license update into the unit e The Ingest Manager GUI window will appear e Select the file that contains the CaptiView license and then click on the Ingest button see Figure 3 below e Reboot the unit to complete the ingest process Local Storage Quit i License to support Closed Caption o free space 725 GB Ctrl Expand All Figure 3 Ingest Window e Once the ingest is complete check the license information by going to Menu gt Control Panel gt License Manager e Follow the steps below for How to Configure the CaptiView System below to finalize the set up process D2K
11. rsion 1 8 Doremi Cinema LLC Figure 10 Connection Message Note If the device is being charged while it is ON it will show as charging even when it is not charging anymore until the device is turned off and on again The charge time will take approximately 2 hours to complete and will last for 24 hours of playing time e Once the CaptiView system is connected play a clip with closed captioning to check if it is working properly Note In case the Digital Cinema Server does not detect the CaptiView Transmitter follow the steps below e Shut off the server do not reboot or log off e Remove all USB devices e Power the server back on e Plug the CaptiView Transmitter in and the server should detect it D2K DP 000469 DRM Page 11 Version 1 8 Doremi Cinema LLC 3 Rear Window Caption Configuration To perform this set up make sure the license is installed and Closed Caption is enabled See steps above to install the license and enable the Closed Caption Open the Device Manager Select the Closed Caption device and check the enable box on the top right see Figure 11 below In the Model field click in the drop down menu and select Wgbh see Figure 11 below The second drop down menu in the Model field will change to RWC automatically see Figure 11 below The Serial Port field drop down menu will change to dev ttySO automatically see Figure 11 below i l Save E seve es Button
12. tch which goes left and right turn the device ON by switching the switch to the left Figure 7 CaptiView On Off Switch e When the CaptiView device is on it will read CaptiView set to auditorium 1 Press A to switch auditorium or C to connect A C L The letters A C and L correspond to the three buttons on the device Figure 8 CaptiView Start Up Message D2K DP 000469 DRM Page 9 Version 1 8 Doremi Cinema LLC Button A The first button from Button L The the left third or last button from the left Button C The second or middle Figure 9 CaptiView Button View e The letters A C and L represent the three buttons that are on the bottom of the CaptiView device see Figure 9 above e A stands for Auditorium and is the first button from the left C stands for Connect and is the second or middle button e L stands for Language a feature that will be included in a future release and is the third or last button from the left e Press the A button repeatedly until the desired auditorium number appears e The CaptiView display must be set to the same auditorium number as the CaptiView transmitter in order to establish a connection e Press the C button to connect to the Auditorium e Amessage saying Connecting to Auditorium will appear D2K DP 000469 DRM Page 10 Ve
13. the setup D2K DP 000469 DRM Page 14 Version 1 8 Doremi Cinema LLC 4 SB430 10 Serial Port Set Up Remove the SB430 10 from packing and begin to set up near a power outlet and computer that has a serial port The serial cable required for a proper connection is a female to female pin to pin cable which should be provided in the package o Serial connection settings are Speed 115200 Data bits 8 Stop bits 1 Parity None Flow control None o Connect and switch the device on and wait for it to boot When the unit is done booting up login as root o Password for root is veeone o jt is recommended to change the root password by doing the command and following the on screen instructions passwd 4 2 1 Configuring the IP Address for SB430 10 e To configure the IP of the SB430 10 type the following command o echo n xxx xxx xxx xxx gt doremi etc ip_addr xxx xxx xxx xxx the desired IP address and then press the Enter key e To configure the netmask type the following command o echo n XXX XXX XXX XXX gt doremi etc netmask and then press the Enter key e To configure the gateway type the following command o echo n XXX XXX XXX XXX gt doremi etc gateway and then press the Enter key 4 2 2 Adding the IP Address of the Digital Cinema Server to the SB430 10 e To add the IP address type the following command o echo n xxx xxx xxx xxx gt doremi etc s430 10 ip conf e Reboot the SB430 10 for the changes to