1. T BAKING TIME STEAM INJECTION AND DAMPER OPENING DISPLAY Display and setting of baking time END OF BAKING steam injection evacuation INDICATOR PROGRAM DISPLAY D oy Eg Selection of a baking program ons AANA 2 eer STEAM INJECTIO INDICATOR VALVE STATE INDICATOR DAMPER OPENING POWER O INDICATOR L O STAND BY START The oven is in preheating mode START STOP BAKING BAKING INDICATOR MANUAL STEAM INJECTION DAMPER OPENING or For steam evacuation ROTARY MANUAL RACK ROTATION p4 About the universal rotary button Y When you turn the rotary button slowly the values are incremented or decremented by step of 1 Y When you turn it more rapidly the values are incremented or decremented quicker according to the speed of rotation 2 UCP200 User Manual 09 02 Model with RTC option TEMPERATURE DISPLAY Display and setting of the oven temperature UNIVERSAL ROTARY SELECTION BUTTON Selection of a baking program or setting of the different parameters BAKING TIME STEAM INJECTION AND DAMPER OPENING DISPLAY Display and setting of baking time steam injection evacuation END OF BAKIN INDICATOR PROGRAM DISPLAY AND ALARM WITH PROGRAMMABLE START DISPLAY Selection of a baking program or a programmable start alarm STEAM INJECT
2. e Press again or wait that the recipe number stops flashing to leave the configuration mode 10 UCP200 User Manual 09 02 Once you have made all the necessary settings go to the next step Wait that the desired preheat temperature of the oven is reached The preheat temperature is reached when a moving symbol 7 appears on the central display indicating the end of the preheating period and when you hear a sound signal lt if the buzzer output is connected You may open the oven door and load the preparation inside When the door is opened a JE moving symbol L appears on the bottom display to inform the user START e After having closed the door press to start the baking The baking indicator is active At the end of baking the indicator of the end of baking is flashing A sound signal is emitted if the buzzer output is connected To acknowledge the end of baking stop of indicator flashing stop of sound signal and return to START preheating press or open the oven door The baking indicator goes off P4 Acknowledging the end of baking does not stop the oven running The oven returns in preheating mode Uh During the baking you have the possibility to inject steam manually in the oven at any time by pressing EN regardless of the automatic injection see page 10 The steam is injected as long as you press the key Uh You may also have the possibility to open or close m
3. by pressing 2 regardless of the automatic steam extraction see page 10 Uh if you modify one of these parameters during the baking the modification will be only available for the current baking 8 UCP200 User Manual 09 02 gt gt The current displayed recipe is not convenient for you you want to modify it and keep the modifications You wish to modify one or more parameters of the recipe and to save the new data for a next use Uh During the modification of the different temperatures and times the oven stays in preheating mode n4 Pressing allows you to enter in the configuration mode or to leave this mode Therefore this allows you to see and or modify one or more parameters Do not forget You have 8 seconds maximum to make the modifications e Press 700 The number of the recipe is flashing e Turnon to select the number of the desired recipe e While the recipe is flashing you may have access to the different parameters gt PREHEATING temperature T1 BAKING temperature T2 e The number of the recipe must be flashing otherwise press Pre e Press i The current temperature t1 is flashing e Turnon O to select the desired temperature e Press again to validate t1 The temperature t2 is displayed To modify it proceed as mentioned for t1 Ui The UCP200 validates automatically the new selections after 8 seconds gt BAKING time e The number of the recipe must be f
4. time and programmable start mode are factory defined Let us now see how you may modify the programmable start parameters Ue To have access to this configuration the UCP200 must be in STAND BY MODE gt gt 1 Configuration of the programmable start mode Uh Before using the programmable start it is necessary to activate this function It is factory fixed on OFF and must be activated by selecting LOC local in the MIS WUP menu The section 5 explains how to modify this parameter gt gt 2 Alarm configuration Uh The programmable start must be deactivated See 3 Activate deactivate the programmable start e Press The date and time of the programmable start are displayed and the alarm number is flashing gt ALARM SELECTION e The alarm number is flashing Turn on O to select the desired alarm A When the alarm number is flashing you may modify the date time and recipe for each alarm UA The UCP200 returns in Stand by mode after 8 seconds and the current time is displayed p4 When you modify the date time and recipe you must absolutely validate otherwise the new selections will not be saved and the new data will be lost after 8 seconds I Uh To leave the configuration mode press gt SETTING THE DATE e Press The date is flashing Turn on O to select the desired date To validate your lt choice press again Uk The alarm date is coded like the current date of the clock see secti
5. To scroll the parameters of the list turn on When the parameter you wish to modify appears on the program display select it by pressing P Modify the parameter value by turning on O and validate by pressing E 09 02 UCP200 User Manual 17 UA After the step above the name of the parameter is flashing Then you may choose another parameter to modify it following the same procedure and so on th When you are modifying the parameters the UCP200 returns to parameters consultation mode after 8 seconds without saving the modification Uh During the modification phase to return in consultation mode without saving START A you can press stop or l START Z4 To go back to the higher level in consultation mode press stop I Uh At any time press to leave the configuration mode of the system parameters Z When you consult the parameters the UCP200 returns to each higher level after 8 seconds and finally returns to stand by mode after 8 seconds too I Ui The carried out modifications will be taken into account when you press again to leave the stand by mode and to go into run mode UCP200 User Manual 09 02 6 Error messages In any state of the system if a critical error occurs an error code message is displayed on Info display There are 3 kinds of errors e Non latched errors Error code is displayed only during defect is present The system returns in its previous state as soon as the defect has dis
6. central display indicating the end of the preheating period and when you hear a sound signal lt if the buzzer output is connected e You may open the oven door and load the preparation inside When the door is opened a Feo Fo X f moving symbol i appears on the bottom display to inform the user START e After having closed the door press to start the baking The baking indicator is active e Atthe end of baking the indicator of the end of baking is flashing A sound signal is emitted if the buzzer output is connected e To acknowledge the end of baking stop of indicator flashing stop of sound signal and return to START preheating press or open the oven door The baking indicator goes off A Acknowledging the end of baking does not stop the oven running The oven returns in preheating mode Uh During the baking you have the possibility to inject steam manually in the oven at any time by pressing et regardless of the automatic injection see page 10 The steam is injected as long as you press the key Uh You may also have the possibility to open or close manually the steam damper at any time by pressing 2 regardless of the automatic steam extraction see page 10 Uh if you modify one of these parameters during the baking the modification will be only available for the current baking 09 02 UCP200 User Manual 5 gt gt The current displayed recipe is not c
7. in the chronological order UCP200 User Manual 09 02 9 Technical data ome fee Resolution of temperature 1 C 1 F display Measurement accuracy Input range 0 25 Cold junction 0 5 Cold junction drift 0 09 Storage conditions Must be protected against UV humidity and external aggressive disturbances Input types Digital 110 230 Vac Analog see Table Sensor list Page 17 One way or two way ventilation 09 02 UCP200 User Manual 25 Digital inputs i Supply voltage see label or NC safety precautions NC or ROTARY Rack position cam Relay outputs Eror l Steam evacuation CI dd Second way ventilation or osed door f Rack rotation ROTARY First way ventilation Steam injection Relay outputs Light Buzzer Analog input Temperature measurement T C Steam extraction Heating 76 mm 2 99 in 4 06 in Dimensions millimeters inches 26 UCP200 User Manual 09 02 Industrial Measurement and Control Honeywell 1100 Virginia Drive Fort Washington PA 19034 51 52 25
8. opened a im ry To moving symbol BAE E appears on the bottom display to inform the user START e After having closed the door press to start the baking The baking indicator is active e Atthe end of baking the indicator of the end of baking is flashing A sound signal is emitted if the buzzer output is connected 6 UCP200 User Manual 09 02 e To acknowledge the end of baking stop of indicator flashing stop of sound signal and return to START preheating press or open the oven door The baking indicator goes off A Acknowledging the end of baking does not stop the oven running The oven returns in preheating mode Uh During the baking you have the possibility to inject steam manually in the oven at any time by pressing et regardless of the automatic injection see page 10 The steam is injected as long as you press the key Uh You may also have the possibility to open or close manually the steam damper at any time by pressing 2 regardless of the automatic steam extraction see page 10 UA if you modify one of these parameters during the baking the modification will be only available for the current baking 09 02 UCP200 User Manual gt gt The current displayed recipe is not convenient for you you choose another recipe e Press P The number of the recipe is flashing e Turnon O to select the number of the desired recipe e Press again to validate or wa
9. 115 Rev 5 0902 Printed in USA www honeywell com imc Honeywell
10. 2 392 F Linear 10 50 mV T C J 0 870 C 32 1598 F PT100 0 400 C 32 752 F Linear 0 20 mA T C K 0 537 C 32 999 F PT100 40 60 C 40 140 F Linear 4 20 mA T C K 0 800 C 32 1472 F PT1000 0 100 C 32 212 F TIC K 0 1300 C 32 2372 F PT1000 0 200 C 32 392 F Ohms T C N 0 1300 C 32 2372 F PT1000 0 400 C 32 752 F Ohms 0 200 Q T C R 0 1600 C 32 2912 F PT1000 40 60 C 40 140 F P34 Ohms 0 2000 Q T C S 0 1600 C 32 2912 F T C T 0 400 C 32 752 F gt gt HOW TO CONFIGURE SYSTEM PARAMETERS 7 e To have access to system parameters set the UCP200 on the stand by mode I by pressing C e Press and hold and turn on O simultaneously On the program display you have access to the elements of the treeview without a password SALO 24 WARNING The PAS parameter password allows you to enter the User password and to access to the User parameters Another password is reserved for the manufacturer to access to the Factory parameters To access to the User parameters CFG from C02 to C08 select the PAS element and enter the password which allows you to unlock the SAL1 the password is the value of the SL1 parameter MIS PAS SL1 see Table on page 16 Confirm your selection by pressing EB e Now you have access to the CFG parameter list available in Table on page 16 Select the CFG list by turning on O and validate by pressing P
11. E PLEASE CONTACT YOUR USUAL TECHNICIAN 09 02 UCP200 User Manual 19 7 Glossary Heating The heating relay is controlled by an internal control loop regarding the current temperature and setpoint temperature Damper opening The damper relay is automatically activated before the end of baking regarding the selected recipe It is automatically disabled when returning into preheating mode Furthermore the user can open or close the damper at any time by pressing the corresponding key except during the automatic steam injection phase the damper is locked in closed position Buzzer The buzzer relay is activated to inform the user when the preheating temperature is reached or when the baking is complete 2 different sequences are used to identify them Y 2long pulse sounds when the preheating temperature is reached Y 3 short pulse sounds in sequence for the end of baking The end of baking signal must be acknowledged by the user Z In case of error the sound is continuous Lighting The light relay is automatically activated during the baking phase or when the door is open The light relay can be also activated during pre heating phase see section 5 Steam injection The steam injection relay is activated either automatically during the baking or manually by pressing the corresponding key The steam injection is disabled when the door is open Ventilation The ventilation relay is automatically activate
12. EE eae A13 Hysteresis ee eel ae a ash Cre gee Once MIS Miscellaneous ieee co eet bree 8 Bs 35 pieces te peoe EIEE ieee serin VER Version ae seer es Ape Se ek Seen ee seen Bt CLK Current Time for RTC model 0 i hh mm 00 00 23 59 DAY Current Day for RTC model 0 1 2 3 4 5 6 7 WUP Wake Up Mode for RTC model QO OFF OFF LOC PAS Passwords Configuration 7 1 E See eee lt r ee 1 Beene SL1 Security Level 1 Access Password ee ee eee ee See Ox sat 1 999 SL2 Security Level 2 Access Password 1 Bs aa a a 999 Security Access Levels SALO Access to SLO without password validation SAL1 Access to SL1 user configuration parameters by validating configured password SAL2 Access to SL2 Fitter configuration parameters password defined by OEM SAL3 Access to SL3 OEM configuration parameters password defined in factory 2 Injection Off Time 0 means Continuous Injection Ventilation Off Time 0 means Continuous Ventilation 1 Way Ventilation Off Time lt gt 0 means Alternative Ventilation 2 Ways for convection ovens only 0 No filter action 0 Lighting is active during pre heating and baking phases 16 UCP200 User Manual 09 02 SENSOR LIST Family Name String Family Name String Family Name String Thermocouples RTD 2 wires 3 wires Linear T C J 0 300 C 32 572 F PT100 0 100 C 32 212 F Linear 0 50 mV T C J 0 400 C 32 752 F PT100 0 200 C 3
13. EY ESO RACK POA OM dera Eeer tessa os E E E AE E O AATA 19 Me GEOSSARYT ai E A A A 20 8 QUESTIONS ANSW ERS icien siaa a aa na Ea aa iaaiiai 22 9 TECHNICAGDATA cie a een eee eee eee eee ee 25 1 UCP200 Overview and Operation You will appreciate the UCP200 operating simplicity and all its advantages to assure you the best bakings The specialist who installed and set up your oven explained to you the various settings and controls Therefore we wish to remind you in this user manual the given explanations to guide you in the use of the UCP200 technology so that you may obtain a full productivity in the best conditions The capacity of the UCP200 allows to include up to 20 baking programs called recipes as well The following paragraphs will allow you to start baking correctly and very easily he This User Manual assists you in the operation of the UCP200 for Convection and Rotary Rack Baking Ovens When the Rotary model differs from the Convection model the following symbol is written p4 When the UCP200 is equipped with the RTC option Real Time Clock the following symbol is written 09 02 UCP200 User Manual 1 gt gt WHAT ARE THE VARIOUS KEYS AND INDICATORS OF THE UCP200 USED FOR Model without option TEMPERATURE DISPLAY Display and setting of the oven temperature HEATING EN UNIVERSAL ROTARY SELECTION BUTTON Selection of a baking program or setting of the different parameters
14. Honeywell UCP200 Universal Digital Controller Programmer For Convection and Rotary Rack Baking Ovens USER MANUAL 91 52 25 115 formerly EN11 6271 Issue 5 09 02 51 52 25 115 CONTENTS 1 UCP200 OVERVIEW AND OPERATION 1 0 ec cceccceceee ene eeceneeeceneeeee essen eesaaeeeeaeessaeesoeneesoenessans 1 gt gt WHAT ARE THE VARIOUS KEYS AND INDICATORS OF THE UCP200 USED FOR ccessseeceeesreeeeeeeeeeeeeeeeeeeaes 2 DP ERSTE STAR TING UP orui e EAA E AE A TE E E O EEE 4 2 THE DIFFERENT BAKING PROGRAMS CALLED RECIPES aassansnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 gt gt The displayed tecipe 1S CONVEMCHE Ior VOU wis sasentaalepeudsteaisarsnaseesitaatealaieciateaiangnil tas essdeotaalesesia tages aaleaoce 5 gt gt The current displayed recipe is not convenient for you but you do not want to modify it definitively 6 gt gt The current displayed recipe is not convenient for you you choose another recipe cceeeeeesneeeees 8 gt gt The current displayed recipe is not convenient for you you want to modify it and keep the PUVO CIT CATON oenar ow iaaa da E E deka cnnimeanoronsemeosaguanscernia weabewmantese 9 gt gt Rotary rack repositioning at the end of baking ccc cccccccccecceeeeeeeeeeeeeeeeeeeeeeeeeees 12 3 PROGRAMMABLE START CONFIGURATION FOR RTC MODELS KY oo eeeeeeeeeee ees 13 gt gt 1 Configuration of the programmable start mode cccceeeeeeeeeeesseeeeeessssseesss
15. IO INDICATOR VALVE STATE INDICATOR DAMPER OPENING POWER INDICATOR PROGRAMMABLE START INDICATOR FOR RTC MODEL Real Time Clock ONLY BAKING INDICATOR STAND BY START The oven is in preheating mode START STOP BAKING AND PROGRAMMABLE START MANUAL STEAM INJECTION DAMPER OPENING or For steam evacuation ROTARY MANUAL RACK ROTATION p4 About the universal rotary button Y When you turn the rotary button slowly the values are incremented or decremented by step of 1 Y When you turn it more rapidly the values are incremented or decremented quicker according to the speed of rotation 09 02 UCP200 User Manual gt gt FIRST STARTING UP e Check that the oven is correctly supplied with water inflow and outflow and powered Turn on the main switch located on the electrical box to power up the oven Uh The displays and indicators light A sound signal is emitted during 3 seconds if the buzzer output is connected The software version and the unit version are displayed during 2 seconds Then the oven is powered up and the UCP200 is in stand by mode UA Internal tests are performed during power up UA in case of error the program display shows the error number See section 6 e Atthis stage the UCP200 stays in stand by mode and the power indicator is active i e Press o to power on the oven Uh A temperature and a time are displayed as well as a program number The indicated tempera
16. according to the programmed Tv time in minutes 3 The steam extraction over the door is automatically activated before the end of baking according to the programmed Te time in seconds 4 The oven lighting is activated during all the baking time 5 ROTARY At the end of baking the rack rotation is automatically stopped in unloading position A During the automatic or manual steam injection the indicator y Is lit gt 1 UA It is not possible to inject steam manually in the oven when the oven door is open o LA In preheating or baking phase when the damper is open the indicator 5 is lit BAKING PARAMETERS Purpose Default value Preheating set point 220 Baking set point 220 Ts Steam injection time at the beginning of baking Tv o ca Total baking time Ts v Damper opening time at the end of baking See section 5 09 02 UCP200 User Manual 15 5 What are the parameters you may configure and those you may not configure gt gt PARAMETER TREEVIEW OVERVIEW ee E SAL Default Unit Min Max Leann ae Ll Se ee See eee EE PAS Password Capture E E A OE EA Rice Ear So eee Oh ee ee Ee eee CFG User Parameters ae ane pea dene ia dasa A Screen cme C02 Temperature Unit Bee TE tetas eet Pip thie Sn nice AAEN Sa ce eee C03 Injection Pulse On time Bin ccc lca lien a ae a an Enh en neers 10 C04 Injection Pulse Off time Ue ee O
17. anually the steam damper at any time by pressing 2 regardless of the automatic steam extraction see page 10 UA if you modify one of these parameters during the baking the modification will be only available for the current baking 09 02 UCP200 User Manual 11 gt ROTARY Rotary rack repositioning at the end of baking gt AUTOMATIC RACK REPOSITIONING Uh At the end of baking the rack rotation is automatically stopped in unloading position gt MANUAL RACK REPOSITIONING AFTER HAVING OPENED THE OVEN DOOR DURING THE BAKING OR IN PREHEATING A During the baking when you open the oven door the rack rotation is so eo stopped On the bottom display a moving symbol L gt appears indicating that you may reposition the rack manually in case of the rack is not stopped in unloading position 4 To reposition correctly the rack noon ll Press the rack stops its rotation when you release or as soon as it arrives in unloading position If you release E and press E again the rack is performing another rotation 12 UCP200 User Manual 09 02 3 Programmable start configuration for RTC models After having chosen and programmed one or more recipes you may now program the start oven time The UCP200 offers 14 programmable start alarms that you may configure Z The current time is displayed in stand by mode The date
18. appeared e Latched errors Error code is displayed until defect has disappeared and user has acknowledged it Only at this moment the system returns in its previous state e Display latched errors Error code is displayed until defect has disappeared and user has acknowledged it but the system returns in its previous state as soon as the defect has disappeared ERRORS FROM E00 TO E49 AND E60 E70 FOR CONVECTION AND ROTARY BAKING OVEN gt E00 TO E09 auto test defect latched An error has occurred during the command s Auto Test Power OFF the oven and power ON it again In case of error persistance please contact your usual technician gt E10 TO E39 system defect latched A system error has occurred Set the UCP200 on the stand by mode and then in preheating mode again In case of error persistance please contact your usual technician gt E40 TO E49 measure defect non latched A measure error has occurred for example burnout This message disappears with the default gt E60 supply defect latched display A supply shutdown has occurred during the baking phase When this message is displayed the baking restarts 2 minutes before ending gt E70 external defect latched An external defect has been detected for example overheating b gt ROTARY ONLY E80 Rack rotation default A rack rotation defect has been detected for example the rack is not turning 4 IN CASE OF ERROR PERSISTANC
19. d during the preheating phase or during the baking The ventilation is stopped when the door is open Extraction The extraction relay is automatically activated at the end of baking according to the parameters configuration or when the door is open 20 UCP200 User Manual 09 02 ROTARY Rack rotation The rack rotation relay is automatically activated during the baking phase or manually by pressing the Rack Rotation key 1 when the door is open At the end of baking or during a manual rotation the rack is automatically stopped at its unloading position 09 02 UCP200 User Manual 21 8 Questions Answers What happens if modify the baking temperature and or time during the baking These modifications have only impact on the current baking phase and will not be saved in the recipe How should do to stop simply the current baking without taking into account the different phases of steam injection impregnation evacuation START You may press at any time during the baking to stop it and to return in preheating mode 2 How should I do to increase the baking time when the indicator of the end of baking is flashing and when a sound signal is emitted if the buzzer output is connected You may increase the baking time by pressing The baking time is flashing Turn on O to select the additional baking time Press again to validate or wait that the selection stops
20. e recipe but the modification will not be saved It will be taken into account only for the next programmable start I p4 To leave the consultation mode press 14 UCP200 User Manual 09 02 4 What happens exactly during the baking according to the used recipes or the changes made in these recipes Here is a detailed description of the baking cycle based on the following recipe An START STAR i i injection Baking Ooo OO E i pt t I Heating Ctrl t1 Ctrl t2 Ctrl t1 Ventilation Steam injection i Damper position Closed Tv mn Extraction 9 Lighting 4 Rack rotation Rack repos t1 Temperature setpoint in preheating phase Recipe Parameter t2 Temperature setpoint in baking phase Recipe Parameter SS active H Closing Tc mn Global baking time Recipe Parameter i l Ts s Effective steam injection time Recipe Parameter e inactive op Opening Ti s Impregnation time System Parameter Tv mn Damper opening time before end of baking Recipe Parameter Te s Extraction time before end of baking System Parameter 1 If there is no steam injection Ts 0 then the impregnation phase will not occur 2 During the steam injection the damper is locked in closed position The damper may be manually activated during the other phases The damper is automatically closed as soon as the preheating phase is beginning It will be open before the end of baking
21. flashing The oven returns in baking mode At the end of the new time the indicator of the end of baking will be flashing and a sound signal will be emitted 2 How should I do to change the impregnation time and the overflow time at the end of baking These are system parameters To modify them the UCP200 must be in stand by mode Then press and simultaneously turn on O to enter in the system parameter configuration Follow the procedure in section 5 22 UCP200 User Manual 09 02 s How should do if do not want to inject steam in the oven at the beginning of baking Select a recipe by pressing P The recipe number is flashing Then turn on O to select the desired recipe number JUST AFTER press E The current programmed injection time is flashing Turn on O to set the injection time at 0 Validate by pressing Et Finally press again to validate or wait that the selection stops flashing Uh This new parameter will be saved in the recipe N How should I do if do not want to open the damper at the end of baking Select a recipe by pressing P The recipe number is flashing Then turn on O to select the desired recipe number JUST AFTER press The current programmed damper opening time is flashing Turn on O to set the damper opening time at 0 Validate by pressing 2 Finally press again to validate or wait that the selection stops flash
22. ing A This new parameter will be saved in the recipe N How should I do if I want that the damper stays opened during all the baking Select a damper opening time greater than the baking time 2 R O TARY What happens if I forget the preparation in the oven at the end of baking At the end of baking the rack is automatically stopped in unloading position Then the preparation will continue to bake just on one side with a burning risk 09 02 UCP200 User Manual 23 The programmable start alarm did not start What can I do fi 24 Let us resume the various stages to be followed The UCP200 must be in stand by mode The programmable start function must be configured in local MIS WUP LOC see section 5 To have access to the alarm configuration you must press programmable start deactivated aN To select one alarm turn on O To set up the date press and turn on Validate by pressing E To set up the time press and turn on Validate by pressing START To activate the alarm press stop UA If you configure several alarms DO NOT FORGET to activate them START by pressing stop for each alarm I Press to return in stand by mode START You may now activate the programmable start by pressing Ea The programmable start indicator is flashing The UCP200 goes in preheating mode at the date and time configured for the first activated alarm
23. it that the selection stops flashing Once you have made all the necessary settings go to the next step e Wait that the desired preheat temperature of the oven is reached e The preheat temperature is reached when a moving symbol Ae appears on the central display indicating the end of the preheating period and when you hear a sound signal lt if the buzzer output is connected e You may open the oven door and load the preparation inside When the door is opened a N Q 7 yt moving symbol amp L appears on the bottom display to inform the user START ee eae e After having closed the door press to start the baking The baking indicator is active e Atthe end of baking the indicator of the end of baking is flashing A sound signal is emitted if the buzzer output is connected e To acknowledge the end of baking stop of indicator flashing stop of sound signal and return to START preheating press or open the oven door The baking indicator goes off A Acknowledging the end of baking does not stop the oven running The oven returns in preheating mode AG During the baking you have the possibility to inject steam manually in the oven at any time by pressing eet regardless of the automatic injection see page 10 The steam is injected as long as you press the key Uh You may also have the possibility to open or close manually the steam damper at any time
24. lashing otherwise press Prae Press The baking time is flashing e urnon O to select the desired baking time e Press again to validate or wait that the selection stops flashing Ut The UCP200 validates automatically the new selections after 8 seconds 09 02 UCP200 User Manual 9 gt AUTOMATIC STEAM INJECTION time at the beginning of baking e The number of the recipe must be flashing otherwise press 700 e Press The currently programmed injection time is flashing being displayed in seconds as you can note it SEC is displayed instead of the recipe number e In less than 8 seconds turn on oO to select the desired injection time Z When the injection time is being modified the indicator is flashing e Press to validate or wait that the selection stops flashing e Press again or wait that the recipe number stops flashing to leave the configuration mode gt AUTOMATIC DAMPER OPENING time at the end of baking e The number of the recipe must be flashing otherwise press Pr e Press 2 The currently programmed damper opening time is flashing being displayed in minutes as you can note it Min is displayed instead of the recipe number e urn on O to select the desired damper opening time Z When the damper opening time is being modified the indicator is flashing e Press to validate or wait that the selection stops flashing
25. on 5 UA if you wish to programm a daily alarm select ALL instead of the date number 09 02 UCP200 User Manual 13 gt SETTING THE CLOCK e Press The time is flashing Turn on O to select the desired time To validate press l again gt POSSIBILITY OF CHOOSING ANOTHER START RECIPE e Press The recipe number is displayed Turn on O to select another recipe To validate press again The alarm number is flashing gt ACTIVATE DEACTIVATE THE ALARM START e To activate deactivate each alarm press The indicator is lightening the alarm is active otherwise the indicator is turned off and the alarm is inactive gt gt 3 Activate deactivate the programmable start START e From the stand by mode press to activate deactivate the programmable start The indicator is flashing when the programmable start is activated e The UCP200 goes in the preheating mode at the date and time configured for the first activated alarm in the chronological order UA It is necessary to validate one alarm at least to have the possibility to activate the programmable start gt gt 4 Consultation of the current alarm with possibility of modifying the recipe p4 To consult the current alarm information the UCP200 must be in stand by mode and the programmable start must be activated e Press to display the current alarm The date and time of the programmable start as well as the recipe number are displayed e You may change th
26. onvenient for you but you do not want to modify it definitively You just want to modify the temperatures preheating and baking and or the baking time The new data will not be saved and the current program will not be modified for a next use but still remains active as long as you do not change the program gt PREHEATING temperature T1 BAKING temperature T2 e Press E The current temperature t1 is flashing e urnon O to select the desired temperature e Press again to validate t1 The temperature t2 is displayed To modify it proceed as mentioned for t1 Ut The UCP200 validates automatically the new selections after 8 seconds gt BAKING time e Press The baking time is flashing e urnon O to select the desired baking time e Press again to validate or wait that the selection stops flashing Uh During the modification of the different temperatures and times the oven stays in preheating mode Ut The UCP200 validates automatically the new selections after 8 seconds Once you have made all the necessary settings go to the next step e Wait that the desired preheat temperature of the oven is reached e The preheat temperature is reached when a moving symbol 7T i appears on the central display indicating the end of the preheating period and when you hear a sound signal lt if the buzzer output is connected e You may open the oven door and load the preparation inside When the door is
27. s he eee eNO Cee IO oo C05 Impregnation Time ee ee ee ee ee a Ooo 300 C06 Extraction Time before end of cooking 1 4 60 ee ee O 300 C07 Light Temporisation before extinction Peet 80 2 tS te eet Oe os fans E C08 Temperature Band Wide for End of Pre Heating Detection 1 i 10 C i C F i 0 C 1 SOC FAC Factory Parameters ee ee eee Peasant Mt ttataaead nud yoann F02 Ventilation On time l 3 i 120 S i 10 i 300 i F03 Ventilation Off time E T a ee ene reese FO5 Ventilation Delay closed door E E a er coma oe ae ee Docs os 30 F06 Heating Security Delay a eee ee ee ee es ee O ee 30 F07 Delay for Rack Rotation Defect detection O3 oi 30 r 10 300 F08 Temperature Min HS 10 C PCIE 10 C 80 C F09 Temperature Max tee S900 4 TOP 90 C 380 C STD Standard Configuration Fo Gok N ieee n ai MES Measure Configuration ER E E ES PERIAATE IAA M01 Main Frequency E eee ane ee en ee 50 60 22225 gt M10 Channel 1 ere e E EPE ed ase Ht APE a ena M11 Sensor Class tus Sua eC t2 TC RT2 RT3 Lin Ohm 2 M12 Sensor Type t te 02 tl See Sensor List ___ M13 Filter pe cee Nee ON Se Oe IO 900 1a M14 PV Bias WS OPO CPR 90 C 80 C LP Control Loops a er re Ho ee Benn ets L10 Loop 1 ie es ee ee Fao Sete ER AERE i L13 Hysteresis a e e C eda Poea C a E a L15 SP Bias 3 4 OPC a CHF o 50 C i 50 C Oi AL Alarms aie ae EP nuk Se eaten o A10 Alarm 1 AE ee eee a EET AE
28. ssssesssssssssesssesseeaaaaaas 13 gt gt 2 Alarm COn OUT ALTO etch Rae ae tases a ae eae Oana esas ae eae a a aan a desecrate eadloat os 13 gt gt 3 Activate deactivate the proctramimable Stan oa etisalat e Sate nce Gee 14 gt gt 4 Consultation of the current alarm with possibility of modifying the recipe ceecececeeeeeeeeeeeeees 14 4 WHAT HAPPENS EXACTLY DURING THE BAKING ACCORDING TO THE USED RECIPES OR THE CHANGES MADE IN THESE RECIPES 0 ccccccceeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeaaeneeeeeseeeeaeeeneees 15 5 WHAT ARE THE PARAMETERS YOU MAY CONFIGURE AND THOSE YOU MAY NOT CONFIGURE Vc ccss ico rca rescence ase aes iste ah scissor ce ei eee 16 PP PARAMETER TREEVIEW OVERVIEW sass sicsc secur siesta tec destaiged tc nica ccuesuuads wu secduatsgndesyictace tae cadas otc tucuwe te aed eacaats 16 gt gt HOW TO CONFIGURE SYSTEM PARAMETERS 2 ccccccccssssecccccsssecccccsssccccceusccececeuscccsssuuecccsseuseeccsseuaneesseuuaeesceeas 17 6 ERROR MESSAGES wxiics cis ccrc cies ae ceeca es ee eet aaah ae eee etc ele ectaceee eset eee 19 PPE OO TOE O09 autotest detect dat hed engnanar eunetanaetomasde tone saheuanaateemaneenwneds 19 ETO TORSO system detect latched aiias scawcucalcuedsiatd wecteasedand E E EA 19 gt E40 TO E49 omeasure detect non latched niaire ET R E EE TEE 19 E60 supply detect latched display hrccsrieni a erase ese aes 19 PETO externabde cer Tatched henn r ia was ional eas 19 gt gt ONI
29. ture is the oven temperature Powering on the oven activates automatically the heating system e You have now 4 possibilities O The displayed program is convenient for you You may wait that the preheat temperature of the oven is reached to start the baking The displayed program is not convenient for you Only for this baking you may modify the temperatures loading and baking and the baking time Then you have to wait that the preheat temperature of the oven is reached to start the baking The displayed program is not convenient for you You may choose another program Then you have to wait that the preheat temperature of the oven is reached to start the baking O The displayed program is not convenient for you You want to modify it In the program you can set the temperatures loading and baking and the baking time eventually the steam injection time as well as the damper opening time Then you have to wait that the preheat temperature of the oven is reached to start the baking Therefore these new baking data will be saved and you might use them again for a next baking e Now letus see the detailed steps of these 4 possibilities 4 UCP200 User Manual 09 02 2 The different baking programs called recipes gt gt The displayed recipe is convenient for you e Wait that the desired preheat temperature of the oven is reached e The preheat temperature is reached when a moving symbol 7 _ appears on the
Download Pdf Manuals