Home
TWO INSTALLATION, LICENSING, AND
Contents
1. EXODUS Il Library Copyright c 2005 Sandia Corporation Under the terms of Contract DE AC04 94AL85000 with Sandia Corporation the U S Government retains certain rights in this software Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 44 e Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 e Redistributions in binary form must reproduce the above copyright notice this list of conditions and the follow ing disclaimer in the documentation and or other materials provided with the distribution e Neither the name of Sandia Corporation nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT IN CIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSI
2. guiobs exe or flscon exe running by looking at the processes tab of the task manager If there are terminate the process 2 Verify that the correct install option was chosen a Client You intend to run FLOW 3D on this computer but will install the license server on another com puter b Server Client You intend to run both FLOW 3D and the license server on this computer c Server You are only installing the license server on this computer If the Server or Server Client installation was not selected for the machine running the license server you will need to run the Server installation on this computer You can check if the necessary software was installed by looking for the files FSDTKNUX exe and Imgrd exe in the licenses folder of the installation directory on the server machine If they are in this folder then the server software was installed 3 Verify that the license file ffow3d lic is in the correct location It should be in the licenses subfolder of the installation directory on the server machine e g C f low3d v11 0 licenses 4 Make sure you are using the correct license file for your server machine You will need to open the license file flow3d lic in a text editor on the server machine a Make sure the server machine computer name or IP address matches what is in the license file This parameter may be edited in the license file to match the computer i The first line of the license file will read SE
3. Microsoft Zip File silverlight Manager Vil FLOW 3D vil 2 3 2 Linux Installation FLOW 3D for Linux is distributed as a gzip compressed tar archive often called a tarball The installation files can be extracted from flow3d tar gz ina terminal window using the command tar xzvf flow3d tar gz The tarball can 2 3 Installation Procedure 31 FLOW 3D Documentation Release 11 0 0 be unpacked into any directory on the filesystem using the C flag For example to extract the tarball to home user use tar xzvf flow3d tar gz C home user Once in the directory where the installation files exist or to which they have been unpacked the script install can be run A preceding dotslash may be necessary depending on whether the current directory is on the system PATH i e install By default this file is executable FLOW 3D is only supported on Red Hat Enterprise Linux 6 or newer and SUSE Linux Enterprise 11 SP2 or newer It may be possible to install on other distributions but due to potential library and package differences Flow Science does not provide technical assistance on these distributions Note e SUSE Linux 11 must be at Service Pack 2 or greater e For SUSE Linux Client Server or Server installations the Isb base package is required If it is not found the installation script will output a reminder e The FlowSight visualization software requires libstdc so 5 These can be installed as follows RHEL yum ins
4. NESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CON TRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAM AGE NETCDF Library Copyright 1993 2013 University Corporation for Atmospheric Research Unidata Portions of this software were developed by the Unidata Program at the University Corporation for Atmospheric Research Access and use of this software shall impose the following obligations and understandings on the user The user is granted the right without any fee or cost to use copy modify alter enhance and distribute this software and any derivative works thereof and its supporting documentation for any purpose whatsoever provided that this entire notice appears in all copies of the software derivative works and supporting documentation Further UCAR requests that the user credit UCAR Unidata in any publications that result from the use of this software or in any product that includes this software although this is not an obligation The names UCAR and or Unidata however may not be used in any advertising or publicity to endorse or promote any products or commercial entity unless specific written permission is obtained from UCAR Unidata The user also understands that UCAR Unidata is not obligated to provide the user with any support consulting training or assistance of any kind with rega
5. 1 When a new or replacement f 1ow3d 1ic is received from the License Administrator place it into the licenses subdirectory found within the directory where FLOW 3D was installed TA je t Computer Local Disk C flowid wi0 1 licenses w y Search licenses Ne Organize Include in library Share with New folder Favorites Name Date modified Type BE Desktop E Imtools 10 13 2010 12 01 Application y Downloads E Irrutil 10 13 2010 12401 Application 1 Recent Places a Librares l Documents a Music e Pictures H Videos mE Computer E Local Disk C Ciy Network 2 items i 2 Start the LMTOOLS utility from either this directory the shortcut on the desktop or the icon in the Start Menu Click the Start Stop Reread tab Verify that the license file is in the correct location by checking the directory shown highlighted in the figure below If correct click the ReRead License File button also highlighted 2 2 General Licensing Information 13 FLOW 3D Documentation Release 11 0 0 LMTOOLS by Flexera Software Inc amp File Edit Mode Help FLESrnet icena services installad on this compute Stat Sevi Stop Server ReRead License File M Force Server Shutdown Pancet segs NOTE This box must be checked to shut down a license server when licenses are borrovaed Using License File Linux 1 When a new or replacement f 1 ow3d 1ic is received from the License Administrator pl
6. 11 0 0 1 Close any open instances of FLOW 3D and close RunnerServer exe It is worth verifying that there are no instances of flow3d exe RunnerServer exe hydr3d exe guiobs exe or fiscon exe running by typing ps A grep flow3d ps A grep hydr3d etc If something is running it can be stopped using the kill command 2 Verify that the correct install option was chosen a Client You intend to run FLOW 3D on this computer but will install the license server on another com puter b Server Client You intend to run both FLOW 3D and the license server on this computer c Server You are only installing the license server on this computer If the Server or Server Client installation was not run on the machine running the license server you will need to run the Server installation on this computer You can check if the server software was installed by looking in the licenses folder of the installation directory on the server machine for the files FSDTKNUX exe and Imgrd exe If they are in this folder then the server software was installed 3 Verify that the license file ffow3d lic is in the correct location It should be in the licenses subfolder of the installation directory on the server machine e g home flow3d v11 0 licenses 4 Make sure you are using the correct license file for your server machine You will need to open the license file flow3d lic in a text editor or using more on the server machine a Make sur
7. 21 FLOW 3D Documentation Release 11 0 0 License Agreement Please read the following license agreement carefully END USER LICENSE AGREEMENT THE TERMS AND CONDITIONS OF THIS END USER LICENSE AGREEMENT SHALL GOVERN YOUR USE OF THE SOFTWARE READ THIS LICENSE CAREFULLY BEFORE INSTALLING AND USING THE SOFTWARE BY USING THE SOFTWARE YOU AGREE TO BE BOUND BY THE TERMS OF THIS AGREEMENT 1 The Software is licensed to You by Flow Science Inc C accept the terms of the license agreement InstallShield 5 This dialog collects user information Enter user and company names and click Next to move forward Customer Information Please enter your information User Hame John Doe Company Mame Generic Inc Install this application for Anyone who uses this computer all users Only for me John Doe InstallShield 6 Now the install location can be chosen The default directory can be used or FLOW 3D can be installed to a specific directory Once the location is chosen click Next When installing to a different location it is important 22 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 that the directory name not contain spaces ampersand characters or multiple dots Choose Destination Location Select folder where setup will install tiles Setup will metall FLOW 30 v7 in the following folder To install to this folder click
8. WUMooOme uncomprsa flow3d v11 BUILD LIN localjs fj F3D HOME home flow3d FLOW3D vil 0 FSD VERSION double PATH SF3D HOME local PATH F3DTENUX LICENSE FILE 10 0 0 238 unlimited FLEXLM TIMEOUT 300000 LD LIBRARY PATH home flow3d FLOW3D vi1 0 qui lib 5LD LIBRARY PATH LD LIBRARY PATH home flow3d FLOW3D vii1 0 qui lib qt 3LD_LIBRARY_PATH LD LIBRARY_PATH home flow3d FLOW3D vil 0 qui lib ifort 3LD_LIBRARY_PATH 1 1 2 4 Remote Solving Setup A new feature in FLOW 3D v11 0 is the ability to connect remote machines called remote servers to a primary workstation referred to as the client and submit simulations from the primary workstation to run on these remote computers In addition to running remote simulations these remote computers retain their ability to run FLOW 3D as a client The following sections will discuss how to set up Remote Servers and Clients 2 4 1 Terminology and Requirements The remote solving setup uses several programs on multiple machines so it helps to define what each program is and the terminology that will be used beforehand A list of the programs and terms is given below e Server The remote machine where the simulation will be run e Client The local machine where the setup is done Simulations can also be run on this machine 38 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 e F3dServerAdmin This is a configuration program that is run on th
9. administration software is not supported on SUSE Linux F3dServerAdmin will not be installed on SUSE machines 2 File Server Configuration configure the settings for RunnerServer e Server Name The Server Name field provides a way for the server administrator to name the server for tracking purposes e IP address The IP address specified here is the IP address of the server machine This field will automat ically be populated with possible entries select the one that is appropriate for your network e Server Port Number This is the port through which FLOW 3D on the client will communicate with RunnerServer on the remote machine This port must be accessible through the firewall e SolverRunner Minimum Maximum Port Number Each time RunnerServer receives a job to run it will spawn a new instance of SolverRunner to run the solver Each instance of SolverRunner communicates simulation status information with the FLOW 3D user interface using a different port so these fields spec ify the range of ports that may be used for communication between FLOW 3D and each SolverRunner This range of ports must be open for communication through the firewall The number of open ports is recommended to be equal to or greater than the number of solver tokens that are available 3 File Solver Registration Configure what solvers are available When a simulation is submitted to run on the remote server it will automatically select the newest compatibl
10. deleted using the respective buttons After registration the available remote servers will be listed in the queue and in the menu when submitting jobs to preprocess or run As with any program running on a network there are some potential issues that may occur 2 5 If a remote server disconnects it may be reconnected by right clicking on the disconnected remote server in the queue shown in red and choosing Try reconnecting to remote server If the file upload fails when submitting a job a simulation in the queue can be removed by right clicking on the simulation and choosing Remove from queue If the results file fails to transmit e g due to a connectivity problem the results file must be manually retrieved from the server License Agreement and Copyright 2 5 1 FLOW 3D End User License Agreement THE TERMS AND CONDITIONS OF THIS END USER LICENSE AGREEMENT SHALL GOVERN YOUR USE OF THE SOFTWARE READ THIS LICENSE CAREFULLY BEFORE INSTALLING AND USING THE SOFT WARE BY USING THE SOFTWARE YOU AGREE TO BE BOUND BY THE TERMS OF THIS AGREEMENT L The Software is licensed to You by Flow Science Inc Licensor on a nonexclusive and nontransferable basis subject to the commercial terms specified in the Acquisition Agreement and subject to the terms and conditions set forth herein IF YOU ARE AN ACADEMIC USER YOU UNDERSTAND THAT YOU ARE OBLIGATED TO RE STRICT YOUR USE OF THE SOFTWARE TO TEACHING ACADEMIC AND OR UNSPONSORED RESEA
11. e Imhostid reports the HOSTID of a system e Imreread causes the license daemon to reread the license file and start any new vendor daemons e Imstat helps monitor the status of all network licensing activities Useful debugging command lmutil Imstat a c full_license_file_path e Imver reports the FlexNet version of a library or binary file Note Using kill 9 to to shut down the license server on Linux computers is not recommended Instead use either Imdown or use the kill command without the 9 parameter 2 2 2 Licensing Terminology Definition of Client and License Server Any computer running FLOW 3D is referred to as a client The computer on which the FlexNet license server is installed will be referred to as the license server The client and server may be and often are the same machine Software Package and Software Distribution The terms software package and software distribution will be used to refer to the directory structure containing all of the data files and executables needed to run FLOW 3D on a particular computer License Files and Servers A valid license file from Flow Science is required to use FLOW 3D This license file will be sent as an email attachment from Flow Science s License Administrator at licenses flow3d com This license file must be saved in the licenses directory of the FLOW 3D installation on the machine that will act as the license
12. physical address gt lt DOLEE B The server network card physical address lt physical address gt can be found by entering sbin ifconfig into a terminal The ethO section will contain the information The server network card physical address is called HWaddr and looks like xx xx xx xx xx xx 5 Check that the necessary environment variables are set on the client machines The easiest way to do this is to run one of the included shell or c shell files 18 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 a Open a terminal and change to the local directory in the install directory e g cd home flow3d v11 0 local b Type more flow3dvars sh or more flow3dvars csh and verify that the environment vari ables are correct The variables and example definitions are shown below If the definitions are incorrect they can be fixed using a text editor like vi i export F3D_HOME home flow3d vi1l1 0 This should point to the FLOW 3D installa tion directory lil export F3D_VERSION double Sets the default solver type to double precision lll export PATH SF3D_HOME 1local S PATH Tells the file system where to find the FLOW 3D executable iv ulimit s unlimited This unlimits the stack size Not doing this is a common cause of segmentation faults v export F3D_HELP usr bin firefox default browser for help files vi export LD_LIBRARY_PATH S LD_ LIBRARY PATH F3D_HOME gui lib vi ex
13. sale use or other dealings in this Software without prior written authorization of the copyright holder Material Properties by Ken Mills The data marked with Ken Mills in the database is provided by M1102 Recommended values of Thermophysical Properties for Selected Commercial Alloys Edited by Ken Mills Published by Woodhead Publishing Ltd Queen s Printer and Controller of HMSO http www asminternational org search journal_content 56 10192 06947G PUBLICATION FLOW 3D and TruVOF are registered trademarks in the USA and other countries 2 5 License Agreement and Copyright 47
14. server More detail about this is given in the Windows Installation and Linux Installation sections below As discussed in Floating vs Node Locked Licenses FLOW 3D can be used on multiple computers but one computer must be selected to be the license server If the computer chosen to be the license server will not actually be used to run FLOW 3D then only the FlexNet license server needs to be installed on that machine Also if the FlexNet license server will be installed on a Windows computer a licensing dongle that attaches to the USB port of the computer will be provided by Flow Science This key is enclosed in the FLOW 3D package Tokens The total number of FLOW 3D solver processes that can be run concurrently is determined by the number of tokens contained in the license file The number of tokens available depends on how many were purchased The license server checks tokens out to client computers on the network and then checks them back in when the application has completed In this process tokens are counted by the license server and when all of the tokens purchased have been checked out no more tokens can be checked out until a token which is in use has been checked in There are several different types of solver tokens The most important distinction is between serial solver tokens and parallel solver tokens Flow Science offers multi processor versions of FLOW 3D for both shared memory SMP and distributed memory
15. space This can be done by selecting one or more simulations in the main list and clicking the Delete Selected Jobs button If necessary the server administrator can also kill running jobs by selecting one or more simulations and choosing the Kill Selected Job button If the administrator kills a running job from the server the simulation is aborted and the results files are not saved This is intended as a last resort option for stopping a running simulation terminating from the client is preferred as the results will be saved and transferred to the client Note Any changes made to the server settings in F3dServerAdmin do not take effect until RunnerServer is restarted 2 4 3 Clients Once the remote server setup is complete see Remote Servers client machines can be configured to use this server for remote solving When adding a new remote server on a client machine the relevant setup information is entered 40 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 in the Preference Remote Server Registration dialog Server name the name of the server machine IP address the IP address of the server machine Port Number the port on the server machine through which RunnerServer communicates with external pro grams User ID the user ID for authentication purposes Password the password associated with the user ID for authentication purposes Existing remote servers can be edited or
16. that it has the right to grant to You a license and warrants that the Software does not infringe third party intellectual property rights Licensor shall indemnify and hold You harmless from and against any claim of infringement of a United States patent or copyright based upon the Software provided You gives Licensor prompt notice of and the opportunity to defend any such claim Licensor shall have the right to settle such claim or at Licensor s option provide You 1 a paid up license 11 substitute functionally equivalent software or 111 a refund of a pro rata portion of the license fee paid for the Software The warranty and the obligation and liability of Licensor expressed in the preceding paragraph are in lieu of and YOU HEREBY WAIVE ALL OTHER GUARANTEES AND WARRANTIES OR OBLIGATIONS AND LIABILITIES OF LICENSOR HEREUNDER EXPRESSED OR IMPLIED ARISING BY LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY AND ALL OBLIGATIONS AND LIABILITIES WITH RESPECT TO USE OF THE SOFTWARE OR USE OF RESULTS AND DATA DERIVED FROM SUCH USE LOSS OF USE DATA REVENUE OR PROFIT OR INDIRECT SPECIAL PUNITIVE OR CONSEQUEN TIAL DAMAGES You agree that the obligations of Licensor as set forth herein shall constitute the sole remedy for a claim relating in any way to the Software provided under this Agreement The liability of Licensor shall in all cases be limited to the purchase pric
17. the U S Government other than the DOD Your rights in the Software will be defined in paragraph 52 227 19 c 2 of the Federal Acquisition Regulations Any use duplication reproduction or disclosure by the U S Government is subject to such restrictions Contractor Manufacturer is Flow Science Inc 683 Harkle Road Santa Fe NM 87505 6 Termination This Agreement shall terminate upon occurrence of any of the following events a any breach of Sections 3 4 or 5 hereof effective immediately b Your failure to observe or perform any other material covenants terms and conditions of this Agreement where such nonperformance is not fully remedied by You within thirty 30 days after written notice from Licensor or c the filing of a petition for Your bankruptcy whether voluntary or involuntary or an assignment of Your assets made for the benefit of creditors or the appointment of a trustee or receiver to take charge of Your business for any reason or Your becoming insolvent or voluntarily or involuntarily being dissolved Upon termination of the Agreement Licensor shall have the right without notice to repossess the Software In addition Licensor shall have all other remedies and damages available to it in law or equity Licensor is entitled to reimbursement from You for any expenses legal fees and or court costs incurred in the enforcement of its rights hereunder or in the collection of damages 7 Warranties The Licensor warrants
18. vl1l1 9 Vendor daemon status on lt name gt F3DTKNUX UP v11 9 Where lt port gt is the port number being used by the server lt name gt is the name of the computer running the server as it appears on the network lt IPaddress gt is the IP address of the server and lt licensepath gt is the full directory location of the license file low3d lic f Note that running multiple license servers on the same machine may result in conflicts in port usage If there is a conflict change or add the port number lt port gt in the license file and repeat step 6 The default port number is 27000 2 2 General Licensing Information 19 FLOW 3D Documentation Release 11 0 0 7 You should now be able to launch and run FLOW 3D 2 3 Installation Procedure 2 3 1 Windows Installation Note e Administrator privileges are necessary to install FLOW 3D on Windows Before installing please close all other running programs If installing on a machine that has FLOW 3D version 10 1 installed please close any running copies of Run nerServer exe This can be done by right clicking the green running person icon in the system tray and choosing Quit or by using the Windows Task Manager and stopping any RunnerServer exe processes shown in the Processes tab It may be necessary to click the Show Processes from All Users button The RunnerServer process may be chosen and the End Process button can then be clicked to close the program If ins
19. CHAPTER TWO INSTALLATION LICENSING AND CONFIGURATION This chapter provides detailed instructions for installing FLOW 3D configuring software licensing and setting up the remote solving features If you have any trouble during the installation please contact our support department at support flow3d com or by calling 505 982 0088 and we will be happy to assist you 2 1 Pre installation 2 1 1 Supported operating systems There are certain operating systems on which FLOW 3D and FlowSight are tested While it may be possible to install and run both of these programs on other operating systems Flow Science supports and provides installation assistance for only the following 64 bit operating systems Microsoft Windows 7 and greater Microsoft Windows Server 2008 and greater SUSE Enterprise Linux 11 Service Pack 2 and greater Red Hat Enterprise Linux 6 and greater Note 32 bit operating systems are no longer supported 2 1 2 Hardware requirements and recommendations Processor An x86 64 compatible CPU is required Multiple processor cores are recommended Intel Core 17 and Intel Xeon CPUs are preferred Memory The software requires a minimum of 2GB RAM per processor core Note that the amount of RAM required is highly problem dependent For simulations with large domains or with complex geometry requiring fine resolution significantly more RAM than the required minimum will be necessary Memory speed has a small effect on simu
20. Directory FLOW 3D v11 0 will be installed in home flow3d FLOW3D vil 0 Choose the type of installation FLOW 3D 1l1 0 and Flexim License Server Client Server Installation FLOW 30D il 0 only Client Installation Flexim License Server only Server Installation None of the above exit Please enter a number from 1 to 4 5 If the FLOW 3D v11 0 only option is chosen the script will display an installation summary and request the name or IPv4 address of the license server This server machine must be accessible by the client Unless networking is configured otherwise ping hostname or ping ip_address will verify whether the machine can be reached 3d v11_BUILD_LIN raid 3 Flezim License Server only Server Installation None of the above amp xit Please enter a number from i to 4 2 INSTALLATION SUMMARY 1 Operating System Red Hat Enterprise Linux Client release 6 4 Santiago 2 OS Type 64 BIT System a Plattorm i 4 Installation type Client Installation Pleas specify the name or IP address sf the License Server 6 If an Installation Type that includes FlexLM is chosen the script will display the installation summary and 34 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 advise that the license will be locked to the ethernet address USB dongles are no longer supported on Linux av11 BUILD LIN raid6 flow3d v1L 0 linux dist
21. Directory The directory on the server where the user s files are to be written before being transferred to the client e Edit Edits the selected user s account settings e Delete Deletes the selected user s account e Email Provided for the administrator to send an email to one or more of the registered clients for disk management maintenance issues etc When the administrator adds a new user during the remote server setup the software automatically generates an email message with the user ID password IP address and server port number to the user The administrator is given the chance to modify the message if desired and then send it The same also occurs if any of those fields are modified when the Edit button is selected where the email message specifically references the change 5 File Start Server Starts RunnerServer allowing client machines to connect and submit jobs When the server is running this automatically changes to Stop Server The server can also be activated and deactivated by toggling the icon of a running person Once RunnerServer is configured and running on the server clients may begin submitting jobs to the server When a job completes the results files are compressed encrypted and copied back to the client machine where they are decrypted and uncompressed The results files are not deleted from the server so the administrator will need to do periodic cleanup of the file system to manage the available disk
22. F The Independent JPEG Group JPEG Jean loup Gailly and Mark Adler gzip and Digital Equipment Corporation DEC Portions of HDF5 were developed with support from the Lawrence Berkeley National Laboratory LBNL and the United States Department of Energy under Prime Contract No DE AC02 05CH11231 Portions of HDF5 were developed with support from the University of California Lawrence Livermore National Laboratory UC LLNL The following statement applies to those portions of the product and must be retained in any redistribution of source code binaries documentation and or accompanying materials This work was partially produced at the University of California Lawrence Livermore National Lab oratory UC LLNL under contract no W 7405 ENG 48 Contract 48 between the U S Department of Energy DOE and The Regents of the University of California University for the operation of UC LLNL DISCLAIMER This work was prepared as an account of work sponsored by an agency of the United States Government Neither the United States Government nor the University of California nor any of their employees makes any warranty express or implied or assumes any liability or responsibility for the accuracy completeness or usefulness of any information apparatus product or process disclosed or represents that its use would not infringe privately owned rights Reference herein to any specific commercial products process or service by trade name
23. If there is a FLOW SD license server running on this system t MUST be shut down before continuing with license server installation Only one FLOW4 3D license server car be running at any time Select Skip F FLOW 30 has never been mstalled on this computer or you are certain there are no license servers running Click the Shutdown Server button to detect a FLOW 30 license server and shut tt down Shutdown Server F a license server i running a new window will open with the detected processes listed Enter Y to terminate t Fino license servers are detected the installation will continue 11 FLOW 3D is now ready to install 26 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 Ready to Install the Program The wizard ts ready to begin installation Click Install to begin the installation IF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Installshield es 12 The FLOW 3D installer will copy the necessary files Clowes 1 007 Sexamples sthrmetrs C S VA oot 13 Next the installer will create firewall exceptions to allow communication to remote license servers and for the new remote solving capability Creating Firewall Exceptions 14 Finally the Microsoft Visual C redistributables will be installed er Installing Visual C Redistibutables 15 The installation is now comple
24. LOW3D v11 0 loecal flowjdvares sh oF E source fhome flowad FLOWSB v11l 0 local flowj3dvars csh in the shell or add it to your bashrc or cshre respectively File hese flewsdsFLOWSD vil d install leg containa a log of inartallation De You want ta install a desktop icon please respond with yes or nd 9 After installation the installation directory will contain a directory structure similar to the one shown A log of the installation named install log will be at the top level and the scripts created by the installer will be in the local directory 2 3 Installation Procedure 37 FLOW 3D Documentation Release 11 0 0 flow3d v1i_BUILD_LIN 11 0 pwd fhome flow3d FLOW3D v11 0 flow3d vll BUILD LIN 11 0 f ls ae FsqaServerAdmin help double FliowSight install iog examples gui licenses flow3d vli_BUILD_LIN 11 0 cd local flow3d vil BUILD LIN local ls admes l gal utilities Makefile patches pltitsi prehyd prehyd s single source flowsd en qm Iimstat bin flowSdvars csh chklic flowsdvars sh delall FlowSight csh delallr FlowSight sh gui runhyd gui runpost nfile gui_runpre nmlcvt libexodus a peek LibexolIv2tfor a olttisi runpost runpre Server dmin csh ServerAdmin sh SolverRunner delhyd delhydr dustrip fsdupdater flow3d flowvru Fiscon get host id qguipost Libhdts a libhdfs hl a libnetcdf a libz a imhostid qasdmesh runali runbatch runhyd Runnerserver
25. Mest To install to a different folder click Browse and select another folder PATH CANNOT CONTAIN SPACES AMPERSAND OR MORE THAN ONE DOT Destination Folder ENT koae Az la 5 rile L Cancel 7 The installation options are shown Choose FLOW 3D and FlexLM license server if this computer should contain both the FLOW 3D software and the license server software Choose FLOW 3D only if the license server software 1 running on a different computer on the network FlexLM license server only installs only the license server components the GUI and Solver will not be installed A FLOW 3D only install would then be required for machines that will connect to this license server If the machine is intended to act as a remote server with the new Remote Solving feature an Installation Option that includes FLOW 3D should be chosen 2 3 Installation Procedure 0 FLOW 3D Documentation Release 11 0 0 Choose an Installation Option Installation options C FLOwW 30 only 6 FlesLM license server Only InstallShield 8 If the FLOW 3D and FlexLM license server or FlexLM license server only installation option was chosen in the previous step this dialog will appear This choice determines the appropriate drivers The USB dongle or Don t know options will install special drivers for the FlexLM USB key Choose a Key Type What type of kep will your license be locked to C Ethernet address Don t know all drivers wi
26. RCH OR SPONSORED RESEARCH THAT CAN AND WILL BE FREELY PUBLISHED WITH NO PROPRIETARY RESTRICTIONS Definitions Acquisition Agreement means a separate executed agreement between You or the entity under whose authorization You are using the Software and Licensor or one of its authorized distributors Such agree ment governs among other things the specific FLOW 3D Product that is licensed to you the number of allowed concurrent instances price license duration and rights to technical support and upgrades Agreement means this End User License Agreement Documentation means manuals release or installation notes related to FLOW 3D Products and or FlowSight including electronic versions thereof FLOW 3D Product means those computational fluid dynamics software programs sold and distributed indi vidually as FLOW 3D FLOW 3D MP FLOW 3D Cast Cast or FLOW 3D ThermoSET and any other similar product which is now available or may become available from Licensor under the same family name FlowSight means the post processing and visualization tool packaged with the FLOW 3D Product FlowSight is a custom version of EnSight limited to use in conjunction with FLOW 3D Products only which is distributed by Licensor under license from Computational Engineering International Inc CEI 2 5 License Agreement and Copyright 41 FLOW 3D Documentation Release 11 0 0 42 Software means such computer program from among the FLOW 3D Products that i
27. RVER lt name gt ii The computer name lt name gt can be found from My Computer Properties Alternatively the IP address can be found by opening a command prompt and typing ipconfig all The IP address looks like xx x x xXXx b If you were sent a USB dongle 1 Verify that the dongle is plugged into the server machine and that the red light on the dongle is lit ii Make sure that the dongle matches the license file A Compare the flexID marked on the dongle with the one at the top of the license file open in a text editor The first line of the license file should look like SERVER lt name gt FLEXID lt flexID gt lt port gt where lt flexID gt is a string of numbers and characters and cannot be modified The dongle flexID must match what is specified in the license file B This can also be checked by opening LMTOOLS located in the licenses folder of the install directory and viewing the FLEXID box on the system settings tab c If your license is locked to an Ethernet MAC address 1 Make sure the server network card physical address matches what is specified in the license file The value in the license file cannot be changed A The first line of the license file will read SERVER lt name gt lt physical address gt lt POLt gt 16 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 B The server network card physical address lt physical address gt can be f
28. ace it into the licenses subdirectory found within the directory where FLOW 3D was installed flow3d vi1_BUILD_LIN es kra i L 1 Pi i in T e f tar ai dal nt Ei N 2 Check whether the license server is running using ps aux grep Imgrd This will provide the PID of any running 14 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 license servers They can be killed using kill PID It is not recommended to use kill 9 on a running Imgrd process i ia ay a L L F Pe Fe ee SUILD LIN licenses 3 It is recommended to run the license server as a user not as root The command to start the new Imgrd process is Imegrd c flow3d lic 1 logfile log where the logfile name may be changed as needed flow3d log is often used k nL ow3d vl1 BUILD LIN de mie e E el il flow3d v11 BUILD LIN flow3d vii BUILD LIN 2 2 General Licensing Information 15 FLOW 3D Documentation Release 11 0 0 2 2 5 Troubleshooting License Problems Windows This guide provides a series of steps that can be used to diagnose and resolve licensing issues with FLOW 3D Feel free to contact our support staff at support flow3d com or at 505 982 0088 if you have trouble at any point 1 Close any open instances of FLOW 3D and close RunnerServer exe an application running in the task tray After closing FLOW 3D confirm that there are no instances of flow3d exe hydr3d exe RunnerServer exe
29. cal directory to launch FlowSight These scripts set up the environment and launch the executable They are named FlowSight sh and FlowSight csh Another option is to allow the install script to create desktop icons to run FLOW 3D and FlowSight These icons set up the environment and run the software They are only created for the GNOME desktop environment which is the default for Red Hat and SUSE Linux If other desktop environments are used the icons will not be created Necessary libraries are included with the distribution in the F3D_HOME gui lib directory The LD_LIBRARY_PATH environment variable is set in the flow3dvars scripts so any libraries not found on the system will be accessible The install script also gives the source command that can be used on your system to set up an environment to run FLOW 3D The command may be added to the user s bashre or cshrc file if desired FLOW 3D can then be run from a terminal prompt using the command flow3d amp or flow3d Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 J flowid vil BUILD FLOW 30 v11 0 Roa been successfully installed Installer did nat Find either firefox r mazilla in your path To ose FLOWSD Help please set FSD HELP to a browser executable Checking system compacibility Shared library libifecere ac 5 not found fhome flowid FLOWID v11 0 qui lib ifors required in Li LIBRARY PATH for libif more 20 5 shared lib
30. cluster environments A shared memory parallel solver token shown in the li cense file as hydr3dp enables FLOW 3D simulations using more than one processor on a multiprocessor computer For the distributed memory version FLOW 3D MP a hydr3d or hydr3dp instance token is required as well as hydr3dmpi rank tokens For example to run a simulation on 16 processors using FLOW 3D MP the license file must have a hydr3d token and 15 hydr3dmpi tokens Unless tokens were purchased for one of the multi processor versions the license file will contain one or more serial solver tokens hydr3d These serial solver tokens can be used on computers running any supported operating system There are essentially an unlimited number of tokens available to run FLOW 3D s auxiliary programs such as the preprocessor the postprocessor and the various visualization options 2 2 General Licensing Information 11 FLOW 3D Documentation Release 11 0 0 Floating vs Node Locked Licenses There are two general types of licenses used to enable FLOW 3D floating and node locked A floating license is the most common type of license and is available to any computer on the network Flow Science can also provide a node locked license Node locked licenses can only be used on the designated computer Both floating and node locked licensing schemes require that one computer be designated as the license server e Floating Licenses To use floating licenses it is
31. d the parties YOU MUST ACCEPT THE LICENSE AGREEMENT FOR FLOW 3D TO BE INSIALLED IF YOU DO NO T ACCEPT THE INSTALLATION WILL BE ABORTED DO YOU ACCEPT ALL OF THE TERMS OF THE PRECEDING LICENSE AGREEMENT Please respond with yes or no Yes The default path for installing FlowsD is fhome flow3d FLOW3D v11 0 Press ENTER to install in the Default Directory OR Enter the full path of the directory where FLOW 3D files will Be installed 4 After the directory has been determined an installation type may be chosen The FLOW 3D v11 0 and Flexlm License Server option is used if this machine should contain both FLOW 3D and the license server software FLOW 3D v11 0 only is used if this is a client machine that will connect to a remote license server Finally Flexlm License Server only is used when this machine will only run the license server software the GUI and Solver will not be installed A FLOW 3D Only install would then be required for machines that will connect to 2 3 Installation Procedure sss FLOW 3D Documentation Release 11 0 0 this license server If the machine is intended to act as a remote server with the new Remote Solving feature an installation type that includes FLOW 3D should be chosen Note that SUSE Linux machines cannot use the Remote Solving feature Press ENTER to install in the Default Directory OR Enter the full path of the directory where FLOW 3D files will be installed Creating Default
32. disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the fol lowing disclaimer in the documentation and or materials provided with the distribution 3 In addition redistributions of modified forms of the source or binary code must carry prominent notices stating that the original code was changed and the date of the change 4 All publications or advertising materials mentioning features or use of this software are asked but not required to acknowledge that it was developed by The HDF Group and by the National Center for Supercomputing Applications at the University of Illinois at Urbana Champaign and credit the contributors 5 Neither the name of The HDF Group the name of the University nor the name of any Contributor may be used to endorse or promote products derived from this software without specific prior written permission from The HDF Group the University or the Contributor respectively DISCLAIMER THIS SOFTWARE IS PROVIDED BY THE HDF GROUP AND THE CONTRIBUTORS AS IS WITH NO WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED In no event shall The HDF Group or the Contributors be liable for any damages suffered by the users arising out of the use of this software even if advised of the possibility of such damage Contributors National Center for Supercomputing Applications NCSA at the University of Illinois Fortner Soft ware Unidata Program Center netCD
33. e installation to run the simulation It should also be noted that only FLOW 3D v11 0 and newer solvers are supported e Add Add a FLOW 3D installation to the available solver list Installation Directory The directory where FLOW 3D is installed on the server machine Release Number The version number associated with the solver in the double folder of the FLOW 3D installation directory This is automatically populated and not editable 2 4 Remote Solving Setup sss ig FLOW 3D Documentation Release 11 0 0 Solver versions A list of the available solvers in the directory specified above These are automatically populated and not editable e Edit Edit the selected solver entry e Delete Remove the selected set of solvers from the list 4 File User Registration Configure user authentication settings e Add Adds a new user to the authenticated user list Full Name The name of the user for the administrator s tracking purposes User ID This is the username that will be used to authenticate the user when a client attempts to connect to the server Password The password associated with the user ID for authentication Confirm Password Re enter the password to avoid typographical errors Email Address The email address of the user The administrator can send setup information to this address Phone Number The phone number of the user for the administrator s tracking purposes Home
34. e of the Software 8 Licensor takes certain steps to attempt to minimize unauthorized use and piracy of the Software In this context the Software may include a security mechanism that can detect the installation or use of illegal copies of the Software and collect and transmit data about those illegal copies Data collected will not include any customer data created with the Software By using the Software You consent to such detection and collection of data as well as its transmission and use if an illegal copy is detected 9 Audit Licensor shall have the right upon reasonable notice to You to audit Your use of the Software no more than once each calendar year to assure compliance with the terms of the agreement between Flow Science and You If an audit reveals that You have underpaid license fees to Licensor by overuse of solver tokens You shall agree to compensate Licensor based upon Licensor s price list in effect at the time the audit is completed If the underpaid fees exceed 5 of the license fees previously paid by You then You shall also pay Licensor s reasonable cost of conducting the audit 2 5 License Agreement and Copyright 43 FLOW 3D Documentation Release 11 0 0 10 General a b c d e f The parties exercise of or failure to exercise any right remedy or privilege under this Agreement will not constitute a waiver of any rights of that party under this Agreement A judicial determ
35. e server to configure RunnerServer for remote solving e RunnerServer This program interfaces between the FLOW 3D user interface and SolverRunner An instance of this runs on both the client for running local simulations and the server for running remote simulations e SolverRunner This program interfaces between RunnerServer and the solver hydr3d Additionally there are two main requirements for the remote solving feature 1 All of the clients and servers must have either a working client installation or client server installation of FLOW 3D before the remote setup can begin see nstallation Procedure for more information on installing FLOW 3D 2 SolverRunner RunnerServer and FLOW 3D all communicate using sockets so certain ports will need to be opened in the firewall 2 4 2 Remote Servers 1 Run F3dServerAdmin on the server machine F3dServerAdmin is an executable that configures and controls the RunnerServer for use as a remote server It is accessed differently depending on the OS e Windows Use the FLOW 3D Remote Admin icon in the FLOW 3D v11 0 Program Group in the Win dows Start Menu This is a shortcut to a batch file in the local folder of the FLOW 3D installation directory e g c flow3d vll1l local ServerAdmin bat e Linux Run the script ServerAdmin sh or ServerAdmin csh located in the local folder of the FLOW 3D installation directory e g home usr FLOW3D v11 0 local ServerAdmin sh Note The remote server
36. e the server machine computer name or IP address matches what is in the license file This parameter may be edited in the license file to match the computer i The first line of the license file will read SERVER lt name gt ii The IP address lt name gt can be found by entering sbin ifconfig in to a terminal The ethO section will contain the information The IP address is called inet addr and looks like xx x x xxx b If you were sent a USB dongle RHEL only 1 Verify that the dongle is plugged into the server machine and the red light on the dongle is lit ii Make sure that the dongle matches the license file A The first line of the license file should look like SERVER lt name gt FLEXID lt flexID gt lt port gt where lt flexID gt is a string of numbers and characters B The flexID is marked on the dongle and at the top of the license file open in a text editor The dongle flexID must match what is specified in the license file and the value in the license file cannot be modified C This can also be checked by opening LMTOOLS located in the licenses folder of the install directory and viewing the FLEXID box on the system settings tab c If your license is locked to an Ethernet MAC address 1 Make sure the server network card physical address matches what is specified in the license file The value in the license file cannot be changed A The first line of the license file will read SERVER lt name gt lt
37. ense administrators to manage FlexNet licensing activities The FlexNet End User Manual is available in the utilities subdirectory of the FLOW 3D installation This manual is available in both PDF and HTML formats For Windows computers the program Imtools exe is provided with all installations With LMTOOLS users can start stop and configure FlexNet license servers get system information get server information and more For more information please see Chapter 12 of FlexNet End User Manual On Windows computers the license manager daemon lmgrd will restart automatically whenever the computer is rebooted On Linux computers however the license manager must be started each time the computer is rebooted To have the license manager start automatically on Linux requires editing the appropriate boot script and inserting the appropriate startup commands See Section 6 2 of the FlexNet End User Manual for more information A summary of commonly used administration tools on Linux is included here Full descriptions of these and other available utilities can be found in Chapter 12 of the FlexNet manual e Imdiag diagnoses license checkout problems Useful debugging command lmutil lmdiag n c full_license_file_path e Imdown gracefully shuts down all license daemons on the license server node 10 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 e Imgrd the main daemon program for FlexNet
38. important that both the network and the computer intended for use as the license server are reliable The TCP IP protocol must be loaded and functional and all intended clients must be able to access the license server Floating licenses may also be accessed through a VPN tunnel The computer that is acting as the license server may be any computer on the network and does not need to have FLOW 3D installed The license server may be a Windows or a Linux computer Users may load FLOW 3D on any client running a supported Linux or Windows computer on the network A hardware key is not needed on a client computer unless it uses a node locked license To employ a floating license on a single computer FLOW 3D should be installed with the client server option The license server and the clients may reside on the same local area network over a WAN or across VPN FLOW 3D must be installed locally on each client An example of a floating license configuration is shown below License Server Client e Node Locked Licenses Users may choose to have their solver tokens locked to a particular computer so that only that computer can run the solver Both floating and node locked licensing schemes have their advantages and disadvantages A floating license is ad vised if several people are sharing a license or it may be necessary to run FLOW 3D on a different computer if a particular computer is busy With a floating license a problem can be set up on o
39. ination that any provision of this Agreement is invalid illegal or unenforceable shall not affect the enforceability of any other provision You acknowledge and agree that You and any third party acting on Your behalf may provide and Licen sor and third parties acting on behalf of Licensor may obtain certain information and data with respect to You including without limitation personal information and Your business in connection with this Agreement including without limitation information and data provided to or obtained by Licensor or third parties acting on behalf of Licensor through a Customer Information Form and otherwise in con nection with ordering registration activation updating validating entitlement to auditing monitoring installation of and access to the Software You hereby consent to Licensor maintaining using and storing such information and data including without limitation personal information if any for such purposes Without limitation of the generality of the foregoing You acknowledge and agree that 1 Licensor may from time to time provide information and data including without limitation informa tion and data about Licensee s use of the Software to Licensor s affiliated and unaffiliated distributors and ii Licensor may make cross border transfers of such information and data including to jurisdictions with privacy or data protection laws that are less protective of You than the jurisdicti
40. is preferable e On Linux operating systems typing sbin ifconfig in a terminal window will provide the MAC address under the heading HWAddr The host name can be found by entering the hostname command in a terminal window When multiple ethernet cards are present multiple MAC addresses may be listed in the output ethO is usually best but if you are unsure which MAC address to use please send a text file or attach a screen capture with the output of the command and the License Administrator will determine the best option Once the host name and MAC address or FLEXID have been received the License Administrator at Flow Science will send the license file f low3d 1ic as an email attachment It is an ASCII text file with encryption codes that allow it to be used only on the computer for which it was generated Check the license file to be sure that it contains the host name and HOSTID that matches the license server 2 2 General Licensing Information 2 2 1 Licensing Software FLOW 3D uses the licensing package FlexNet Publisher by Flexera Software FlexNet enables FLOW 3D licenses to be shared across a network More information about FlexNet and its tools can be found below under the FlexNet License Administration Tools section A FlexNet License Administration Guide is available in the utilities subdirectory of the FLOW 3D installation FlexNet License Administration Tools Flexera Software provides utilities for users or local lic
41. lation time and typically 1333 or 1600 MHz memory is adequate Graphics The FlowSight postprocessor works best with a workstation card nVidia Quadro K series cards or AMD FirePro W series cards are highly recommended nVidia s GTX series 660 and above have shown decent performance on desktop and notebook machines FLOW 3D for Windows requires at least 1GB of free disk space On Linux operating systems at least 1 2GB of free disk space is necessary Additional space is required for simulation results which can be upwards of 100GB depending on the simulation FLOW 3D Documentation Release 11 0 0 2 1 3 Licensing requirements Please ensure that you have a valid FLOW 3D license file or the name or IP address of your FLOW 3D license server before beginning the installation If you do not have a license file or a license server please contact your sales associate or licenses flow3d com and provide the following information e The host name of the machine that will run the license server software e Either the FlexID if using a hardware dongle the FlexID is printed on the side of the dongle or the MAC address of the machine If the MAC address is not known e On Windows operating systems the host name and MAC address can be found by opening the command prompt and entering ipconfig all When multiple ethernet cards are present multiple MAC addresses may be listed in the output The connected ethernet device or the first in the series
42. ll be installed InstallShield 24 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 9 If the FLOW 3D only installation option was chosen this dialog will be shown instead It allows an IPv4 address or a server name to be specified for the license server If unknown the IP address can be found by opening the command prompt and entering ipconfig all on the license server machine The name can be determined by Opening a command prompt or terminal window and issuing the command hostname When using a hostname the server should respond to ping requests The name required may differ based on the network For example a machine may respond to ping host company com but not to ping host If this is the case the full name must be used If the hostname entered is not reachable the client will not be able to check out a license FLOW 3D vil InstallShield Wizar License Server Please enter the P4 address or name of your license server For example 10 0 0 171 or licenses mydomain local 10 If a license server is being installed FLOW 3D will ask to temporarily shut down any existing license servers This allows the FLOW 3D license as well as FlexLM licenses from other vendors to be served This can only be skipped safely when no other software that uses FlexLM licensing is installed including older versions of FLOW 3D 2 3 Installation Procedure 8 FLOW 3D Documentation Release 11 0 0
43. ne computer while using another to run the FLOW 3D solver on a second problem If other machines or problems are using all available tokens the solver will not run until a token becomes available The main advantage of a node locked license is the ability to ensure that token s are always available to a specific machine and not available to others on the network Note All licenses are floating licenses unless specifically requested as node locked 12 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 2 2 3 Moving License Servers When a floating license is locked to a fixed host ID such as an Ethernet address or host ID it is recommended that users choose a server which is likely to be used for the duration of the license Changing license servers can be done once a year without incurring a re licensing fee Re licensing fees are not necessary maximum one change per year when users use a USB or parallel port hardware key dongle as their host ID To move the dongle and hence license server to a different computer the user may change the first line in the license file to reflect the computer name change For example if the license server was previously running on a server named Celsius and will be moved to Kelvin the first line in the license file would be changed from SERVER Celsius FLEXID your ID to SERVER Kelvin FLEXID your ID 2 2 4 Installing a New Replacement License File Windows
44. on in which You are domiciled You acknowledge and agree that such policies may be changed from time to time by Licensor Licensor reserves the right without limitation and without obtaining prior approval from or notice to You to make changes in and to the Software This Agreement shall be governed by and construed in accordance with the laws of the United States and the State of New Mexico as applied to agreements entered into and to be performed entirely within New Mexico between New Mexico residents without reference to conflict of laws This Agreement and the performance of the Parties required hereunder shall not be governed by or otherwise subject to the United Nations Convention for the International Sale of Goods Any civil suit or proceeding relating to this agreement shall be brought only in U S Federal District Court or State District Court within the State of New Mexico and each of the Parties consent to the personal jurisdiction and venue of such courts Judgment upon any award made in such proceeding may be entered and enforced in any court of competent jurisdiction In the event of any conflict between the terms of this Agreement and the applicable Acquisition Agreement the terms of the Acquisition Agreement shall prevail If there are any terms in either agreement which are different from but not inconsistent or in conflict with the other agreement then such terms shall bind the parties 2 5 2 Supplemental License Agreements
45. opyrights the Software contains trade secrets and proprietary information of Licensor and CEI and You agree not to act in contravention of any of Licensor s or CEI s intellectual property rights You acknowledge that Licensor and CEI own the aforementioned rights and have the following exclusive rights with regard to the applicable portions of the Software to reproduce it to adapt transform or rearrange it to prepare derivative works from it and to control its distribution The Software is licensed not sold No title to or ownership of the Software or any part thereof is hereby trans ferred to You and all rights not specifically granted to You shall remain with Licensor and CEI as appropriate You acknowledge that by virtue of this Agreement You acquire only the right to use the Software pursuant to the terms of this Agreement You agree to take all necessary action to protect the confidential and proprietary information in the Software to avoid the disclosure of the contents of the Software to any other person firm or corporation and to treat the Software with the same degree of care that You provide Your own confidential information You agree to credit Licensor and the Software in any written or verbal presentation where results obtained using the Software are discussed You may use the Software only as expressly permitted in this Agreement You may not 1 rent loan transfer relicense distribute or otherwise assign the Softwa
46. ound by opening a command prompt and typing ipconfig all The server network card physical address looks like xx xx xx xxX XX XX 5 Check that the necessary environment variables are set on the client machines a Right click on the FLOW 3D icon and choose Edit b Verify that the following variables have the correct values Note that the values below are based on the default install location i F3D_HOME C flow3d v11 0 the FLOW 3D installation directory u PATH C flow3d v1l1 0 local lii F3DTKNUX_LICENSE_FILE xx x x xxx this should point to the server IP address pre ceded by the symbol 6 Verify that the firewall on the server machine has exceptions for the license daemons a Go to Start Control Panel Windows Firewall b Click Allow a program or feature through Windows Firewall c Verify that FLOW 3D_v11_license_daemon and FLOW 3D_v11_vendor_daemon are in the list and checked for the appropriate networks If not choose Allow another program and browse to the li censes folder of the installation directory and add exceptions for mgrd exe and FSDTKNUX exe 7 Now restart the license server and reread the license file on the server machine a Open a command prompt and change to the licenses folder in the install directory e g cd c flow3d v1l1 0 licenses b Type lmutil lImdown c flow3d 1lic to shut down any running license daemons c Type lmgrd c flow3d lic 1 flow3d 1og to restart the ser
47. personal jurisdiction and venue of such court s Judgment upon any award made in such proceeding may be entered and enforced in any court of competent jurisdiction if In the event of any conflict between the terms of this Agreement and the appl icable Acquisition Agreement the terms of the Acquisition Agreement shall preva il If there are any terms in either agreement which are different from but not inconsistent or in conflict with the other agreement then such terms shall bin id the parties YOU MUST ACCEPT THE LICENSE AGREEMENT FOR FLOW 3D TO BE INSTALLED IF YOU D NO T ACCEPT THE INSTALLATION WILL BE ABORTED DO YOU ACCEPT ALL OF THE TERMS OF THE PRECEDING LICENSE AGREEMENT Please respond with yes or no 3 FLOW 3D can be installed to a directory of your choosing The default is home current_user FLOW3D v11 0 Press Enter to use this To change the default enter the full path here and press Enter each of the Parties consent to the personal jurisdiction and venue of such court Ss Judgment upon any award made in such proceeding may be entered and enforced in any court of comp tent Jurisdiction In the event of any conflict between the terms of this Agreement and the appl icable Acquisition Agreement the terms of the Acquisition Agreement shall preva il If there are any terms in either agreement which are different from but not inconsistent or in conflict with the other agreement then such terms shall bin i
48. port LD_LIBRARY PATH SLD_LIBRARY_PATH SF3D_HOME gui lib qt Vill export LD LIBRARY _PATH LD_LIBRARY_PATH SF3D_HOME gui lib ifort ix export F3DTKNUX_LICENSE_FILE xx xx xx xxx This variable is used on client ma chines and should point to the server name or IP address c Type source flow3dvars sh or source flow3dvars csh to set the variables defined in the shell or c shell This command will need to be called every time a new terminal is opened to launch FLOW 3D Alternatively this command can be added to the bashrc file to make this an automatic process 6 Now restart the license server and reread the license file on the server machine a Open a terminal and change to the licenses directory in the install directory e g ed home flow3d v1l1 0 licenses b Type lmdown c flow3d 1ic to shut down the running license daemons c Type lmgrd c flow3d lic 1 flow3d log amp to restart the server 1 The amp is to run the daemons in the background ii You may need to allow firewall exceptions for FSDTKNUX exe and lmgrd exe d Type lmreread c flow3d 1lic to reread the license file e Perform a status check by typing lmstat c flow3d lic This will display the server status It should now report Detecting lmgrd processes License server status lt port gt lt name gt License file s on lt name gt lt TPaddress gt License file s on lt name gt lt licensepath gt lt name gt license server UP MASTER
49. rary libifport 30 5 not found Thome flowsd FLOWIDs v11 0 gui lib ifort ia a LD LIBRARY PATH for libif POLE oS an 5 shared library libimf so not found fhomes flow3d FLOWIDs 11 O fquaslibsifoert is required LD LIBRARY PATH for lihim f 30 shared library libire so neat faund fhome flow3d FLOWID v11 0 qui libsifort is required in LD LIBRARY PATH for libir 2 50 foserlecal Trolltech Qt 4 7 4 1ib lLipgckml so 4 aymbolic Link to Libjcel ao 4 7 4 foes lecal Trelltech Ot 4 7 4 116 1iBOtOp enNGL 6 4 syRbolic link to lLiIbQpeOpen FL 80 4 T 4 fuseflocal Trolitech Qt 4 7 4 1ib 1libgtGui so 4 symbolic link to libQ esui g0 4 7 9 fase local Trolltech Qt 4 7 4 lib libgthetwork 30 4 symbolic link to libOcHecw JEK J0 4 7 4 fase lecal Trelltech 9t lt 4 7 4 116 libgtcore ac 4 symbolic link to Lib jctore 86 4 neal To resolve the missing Libraries on your system the LD LIBRARY FATH environment variable has been appended in the flow3dvars sh and flowadvars csh Files to include the libraries included with FLOW SE The Libraries included with FLOW 30 provide maximum compeacibility Bur may not be the Latest available ESE your ayatem If yeu chease to resolve theme Libraries by installing the appr apriatce package comment out the corresponding setting in flowddvars sh and or flowSdvar 3 05h and source them to refresh the LO LIBRARY PATH environment variabile 6 ue FLOWSD please run saqurce home flowisds F
50. rd to the use operation and performance of this software nor to provide the user with any updates revisions new versions or bug fixes THIS SOFTWARE IS PROVIDED BY UCAR UNIDATA AS IS AND ANY EXPRESS OR IMPLIED WAR RANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABIL ITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL UCAR UNIDATA BE LIABLE FOR ANY SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE DATA OR PROFITS WHETHER IN AN ACTION OF CONTRACT NEGLIGENCE OR OTHER TORTIOUS ACTION ARISING OUT OF OR IN CONNECTION WITH THE ACCESS USE OR PERFORMANCE OF THIS SOFTWARE HDF5 Library Copyright Notice and License Terms for HDF5 Hierarchical Data Format 5 Software Library and Utilities HDF5 Hierarchical Data Format 5 Software Library and Utilities Copyright 2006 2013 by The HDF Group NCSA HDF5 Hierarchical Data Format 5 Software Library and Utilities Copyright 1998 2006 by the Board of Trustees of the University of Illinois All rights reserved Redistribution and use in source and binary forms with or without modification are permitted for any purpose in cluding commercial purposes provided that the following conditions are met 2 5 License Agreement and Copyright 45 FLOW 3D Documentation Release 11 0 0 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following
51. re or any or all of Your rights hereunder without prior written consent of Licensor and any attempt at the same shall be wholly void and ineffective for all purposes 11 copy the Software except to make archival copies for backup purposes 111 decompile disassemble or otherwise reverse engineer the Software iv publish the Software for others to copy or v use the Software in any way that is against the law or contrary to the terms of this Agreement You may use the Documentation only in Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 support of Your use of the Software and You may print or duplicate the Documentation but only for internal use and provided that each copy includes all of the copyright or related notices of the original The License and the rights granted hereunder are subject to Your compliance with all laws regulations orders or other regulations relative to export or redistribution of the Software that may now or in the future be imposed by the government of the United States or any agency thereof or of any other country into which the Software may be transported Any act of noncompliance shall immediately terminate this License If You are the USA Department of Defense DOD the Software is subject to Restricted Rights as that term is defined in the DOD Supplement to the Federal Acquisition Regulations section 252 227 7013 c If You are any unit or agency of
52. s licensed to You hereunder FlowSight the Documentation and any backups or other copies License Management In connection with the License granted herein Licensor will issue one or more electronic license files which shall be tied to either a FLEXIm hardware dongle or to the Ethernet address of a designated server Such license file s will enable the running of the Software s preprocessor and postprocessor and control the number of concurrent instances of the Software s solver module and FlowSight in use You agree not to take any steps to avoid or defeat the purpose of such licensing measures Use of the Software without a license file or in excess of the number of authorized concurrent instances is expressly prohibited Upon request You agree to submit log files to Licensor for verification Use of the Software on a network is restricted to a fifty mile radius around one geographic location unless otherwise authorized by Licensor Maintenance If arrangements for technical support have been made only the person designated by You as the Registered User or persons who have attended a FLOW 3D Training Class will be entitled to contact Licensor or its authorized distributor to seek technical support Technical support will be provided via telephone e mail web based meetings fax and or mail during normal business hours In order to enable Licensor to provide timely and beneficial technical support for the Software You agree to in
53. stall updates fixes circumventions and corrective code to the Software in a reasonable time after receipt thereof and to be responsible for the installation and administration of the Software on platforms officially supported by Licensor Licensor shall not be obligated to provide technical support unless You are using the current version of the FLOW 3D Product You are licensed to use or the previous major release thereof If You are an academic user and have purchased maintenance service such service is limited to the following a Licensor will provide User with software upgrades when they become available b Licensor will assist in installation of the code and will answer questions about how to use the input variables to implement the various models in FLOW 3D c at its option Licensor will analyze results that appear obviously incorrect because they don t seem to reproduce simple analytical results or expected conservation laws d Licensor will also provide access to a number of subroutines to allow users to implement small changes to FLOW 3D including boundary conditions and material properties e Licensor will not assist in the making of revisions or customizations to the Software Use and Limitations The Software is the property of Licensor or with respect to FlowSight of CEI You recognize that the Software is copyrighted under the laws of the United States of America and international treaty provisions Notwithstanding the c
54. tall compat libstdc 33 SUSE zypper install libstdc 33 1 Execute the install script in the directory where the tarball was unpacked The license agreement can be read prior to installing the software ee flow3d v 1_BUILD_UN raid6 flow3d v11 0_ flow3d vl1i_BUILD_LIN unix ls e gil EEG 32 and 64 Linux lic gz install x86 64 Linux Tflowsight gz LICENSE AGREEMENT x86 64 linux gui gz run install x86 64 xB6 64 linux license util flow3d v11_BUILD_LIN unix install Do you want to read the LICENSE AGREEMENT Please respond with yes or no yes 2 If all the terms are acceptable typing y or yes and pressing Enter will continue the installation 32 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 He This Agreement shall be governed by and construed in accordance with the laws of the United States and the State of New Mexico as applied to agreements ente red into and to be performed entirely within New Mexico between New Mexico resid ents without reference to conflict of laws This Agreement and the performance of the Parties required hereunder shall not be governed by or otherwise subject ito the United Nations Convention for the International Sale of Goods Any civil Suit or proceeding relating to this agreement shall be Brought only in U 5 Fed ral District Court or State District Court within the State of New Mexico and each of the Parties consent to the
55. talling on the Windows 8 operating system please consult the Special Considerations for Windows amp The installation can be started by double clicking the downloaded flow3d exe file 1 On Windows operating systems a User Account Control dialog similar to the one below will appear The Verified publisher entry should confirm that the executable has been digitally signed by Flow Science Inc H User Account Control Do you want to allow the following program to make changes to this computer La Program name setup Verified publisher Flow Science Inc File origin Network drive Change when these notifications appear 2 Next the Preparing to Install dialog will be displayed It requires no user input and will disappear after several seconds 20 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 FLOW 3D vil InstallShield Wizard Preparing to Install FLOW 30 v11 Setup i preparing the InstallShield Wizard which will guide you through the program setup process Please wait Extractig FLOW S0 v11 rst OO m Cancel 3 The next dialog to appear is the Welcome screen Click Next to continue FLOP 3D vit instalishield Wizard 4 The next dialog is the FLOW 3D end user license agreement Please read it carefully If all the terms are acceptable click the Next button to signify agreement and move to the next dialog 2 3 Installation Procedure
56. te 2 3 Installation Procedure 27 FLOW 3D Documentation Release 11 0 0 InstallShield Wizard Complete The InstallShield Wizard has successtully installed FLOW 30 WIT Click Finish to esit the wizard Back Finish Cancel 16 After installation an opportunity is presented to learn about new features Installation complete Would you like to read What s New in FLOW 3D re ee 17 The FLOW 3D FlowSight and LMTOOLS icons will now appear on the desktop LMTOOLS allows for interaction and configuration of local or remote license servers 28 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 Vil ral FLOW 3D vil a Flows g ht Je ae LMITOOLS 18 Also there will be a new Program Group in the Windows Start Menu CamStudio 2 7 CCleaner l Citrix Matt Taylor Core Temp x CPU Z Documents U Editra Pictures FileZilla FTP Client Ji FLOW 3Dv11 o FLOW 3D Remote Admin l FLow 3D v11 ieia F FlowSight Install MiniMagics Control Panel LMTOOLS f 7 Devices and Printers Foxit Reader 5 0 Default Programs Jawa MagicISO Help and Support Maintenance Microsoft Office 4 Back a a oe a Shut down oe Search programs and files 2 3 Installation Procedure sss ig FLOW 3D Documentation Release 11 0 0 Special Considerations for Windows 8 Flow Science highly recommends updating Windows 8 to version 8 1 Update 1 or the newest
57. trademark manufacturer or otherwise does not necessarily constitute or imply its endorsement recommendation or favoring by the United States Government or the University of California The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or the University of California and shall not be used for advertising or product endorsement purposes CURL Library COPYRIGHT AND PERMISSION NOTICE Copyright c 1996 2014 Daniel Stenberg daniel haxx se All rights reserved Permission to use copy modify and distribute this software for any purpose with or without fee is hereby granted provided that the above copyright notice and this permission notice appear in all copies 46 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 THE SOFTWARE IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY FITNESS FOR A PAR TICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM DAMAGES OR OTHER LIABILITY WHETHER IN AN ACTION OF CONTRACT TORT OR OTHERWISE ARISING FROM OUT OF OR IN CON NECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE Except as contained in this notice the name of a copyright holder shall not be used in advertising or otherwise to promote the
58. un e INSTALLATION SUMMARY 1 Operating System Red Hat Enterprise Linux Client release 6 4 Santiago 2 OS Type 64 BIT System 3 Platiorm 1 4 Installation type Client Server Installation FLOW 3D License will be locked to the Ethernet Address Please contact Fliow 3D License Administrator licenses flow3d com to get your license file Would you like to continue 7 please respond with yes or no 7 The installation will now unpack the tarballs that are needed for the selected Installation Type 2 3 Installation Procedure FLOW 3D Documentation Release 11 0 0 36 3 Flezlin License Server only SeEever Ingeallation 4 Hone of the above xit Flesase enter number from 1 to 4 gt FLEELPOrR i 1 J Installation ura 4 i AILS LOLLI bpe the license server will be set t Installing Flow3d v1ll1 0 only install type 3 plitica i Eid hose homes Plowdd FLORID Y1 0 CYEPenE operating system Linux Installing x86_64 linux solver gz Installing x84 64 linux gui gz Installing 86 64 linux license uril gz Installing 86 32 and 64 linux lic gz Installing help util gz Installing x86 64 linux flowsight gz 8 Asa final step the install script checks the system for the libraries needed to run FLOW 3D Two shell scripts for launching FLOW 3D flow3dvars sh and flow3dvars csh are written into the local directory of the installation path Another pair of scripts is included in the lo
59. ver You may be notified that the firewall is blocking the license daemons If this is the case allow exceptions for F3DTKNUX exe and Imgrd exe d Perform a status check by typing Imutil lIlmstat c flow3d lic This will display the server status It should now report Detecting lmgrd processes License server status lt port gt lt name gt License file s on lt name gt lt IPaddress gt License file s on lt name gt lt licensepath gt lt name gt license server UP MASTER v11 9 Vendor daemon status on lt name gt F3DTKNUX UP v11 9 Where lt port gt is the port number being used by the server lt name gt is the name of the computer running the server as it appears on the network lt IPaddress gt is the IP address of the server and lt licensepath gt is the full directory location of the license file flow3d lic Note that running multiple license servers on the same machine may result in conflicts in port usage If there is a conflict change or add the port number lt port gt in the license file and repeat step 6 The default port number is 27000 8 You should now be able to launch and run FLOW 3D Linux This guide provides a series of steps that can be used to diagnose and resolve licensing issues with FLOW 3D Feel free to contact our support staff at support flow3d com or at 505 982 0088 if you have trouble at any point 2 2 General Licensing Information 17 FLOW 3D Documentation Release
60. version available before installing FLOW 3D e On all versions of the Windows 8 operating system including those which have been updated the following considerations apply Secure boot must be disabled for the Sentinel HASP USB drivers to install Please see http technet microsoft com en us library dn48 1258 aspx for the procedure The Creating Firewall Exceptions dialog is not shown However the firewall exceptions are created e When the Windows 8 operating system has not been updated the desktop icons are not created by the installer automatically One potential solution is to install a third party Start Menu replacement such as Classic Shell or Start8 If a Start Menu replacement is installed prior to installing FLOW 3D the icons will be created correctly Another option is to use the Modern interface All Apps view This can be done by right clicking the Start Screen then clicking All Apps at the lower right All apps There will be a Program Group for FLOW 3D FLOW 30 Remote Admin FLOW 3D w11 FlowSight LMTOOLS Right click one of the icons and choose Pin to Start at the lower left to place the icon on the main Start Screen 30 Chapter 2 Installation Licensing and Configuration FLOW 3D Documentation Release 11 0 0 V52012 x64 Visual Studio Cross Tools 2012 Developer Windows Command Software ma M Windows App Windows Cert Kit Performance a kK kiz
Download Pdf Manuals
Related Search
Related Contents
dreamGEAR Character P10~11 Velodyne Acoustics SA-7 User's Manual User Guide: Bayonet Units PDF 428kB ThinkPad® Guía de seguridad y garantía NAKー620 Copyright © All rights reserved.
Failed to retrieve file