Home
MODEL GT15-60VLTN BACKLIGHT User`s
Contents
1. PLC CPU power supply as well and remove the GOT from the control panel before backlight replacement If all phases are not shut off it may cause an electric shock If backlight is replaced with the GOT on the control panel the GOT may drop off resulting in injuries CAUTION Make sure to wear gloves during backlight replacement Failure to do so may cause injuries Make sure to start the backlight replacement 5 or more minutes after power off of the GOT Failure to do so may cause burn injuries as the old backlight holds heat for a while STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Before handling the GOT make sure to touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the GOT to fail or malfunction DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation 3 BACKLIGHT REPLACEMENT Manuals The following shows manuals relevant to this product Detailed Manual Manual name Manual num
2. special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano It
3. 50 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 axMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan
4. MITSUBISHI MODEL GT15 60VLTN BACKLIGHT User s Manual Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 60VLTN U MODEL CODE 1D7M43 IB NA 0800328 D 1001 MEE GRAPHIC OPERATION TERMINAL GOTioo9o0 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause lt DANGER hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user BACKLIGHT REPLACEMENT PRECAUTIONS lt gt DANGER Make sure to externally shut off all phases of GOT power supply When GOT is connected via the bus type connection make sure to cut all phases of
5. aly Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 110
6. ber SH 080528ENG Option 1D7M23 GT15 User s Manual Relevant Manuals For relevant manuals refer to the PDF manuals stored in the CD ROM for the drawing software used A CAUTION hazardous conditions resulting in medium or l slight personal injury or physical damage l 2005 MITSUBISHI ELECTRIC CORPORATION 1 OVERVIEW This User s Manual describes Model GT15 60VLTN backlight hereafter abbreviated to the backlight Refer to the GT15 User s Manual for the applicable GOT Product name Model name Description Backlight GT15 60VLTN For 8 4 TFT VGA 2 SPECIFICATIONS The performance specifications of the backlight are indicated below The general specifications of the backlight are the same as those of the GOT For the general specifications of the backlight refer to GT15 User s Manual Item Specifications Kind Cold cathode tube back light Life 40 000h or more Operating ambient temperature 25 C Weight 9g The GOT includes the backlight for liquid crystal display panel Please note that the backlight intensity decreases in time The backlight needs to be replaced when the display section becomes dark due to the decreased intensity and the picture is unclear The backlight replacement procedure is described below 1 Power off the GOT 2 Disconnect the power supply cable and communication cable Remove t
7. e right 8 Mount a new backlight in the reverse procedure of removal Also assemble the case in the reverse procedure of disassembly Tighten the GOT rear fixing screws within the torque range of 0 36 to 0 48 Nem When mounting the case take care of not biting the cables between the case and the GOT Point Be careful not to disconnect the battery cable from the board when replacing the backlight When the battery cable is disconnected data will be erased It is recommended to back up data before replacing the backlight 1 Precautions for backlight replacement When the battery cable is disconnected connect it to the board again within 30 seconds After 30 seconds or more data in the D drive recipe data alarm history and clock data will be erased 2 Data backup and resetting Data can be backed up or reset with the following operation Recipe data Data can be backed up by uploading the data with GT Designer2 For details refer to the GT Designer2 Version Basic Operation Data Transfer Manual Clock data When the data is erased set it again after attaching the battery Alarm history Backup is not allowed Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by
8. he GOT from the control panel 3 Remove the expansion unit cover on the right side of the GOT Remove the expansion unit e g bus connection unit if it is mounted 4 Remove the GOT rear fixing screws 8 pcs with a screwdriver 5 Remove the case after passing the battery holder through the mounting hole When removing take care of not cutting the cable of the battery holder Expanded figure of part A in 4 6 Disconnect the cable connector of the backlight from the GOT side connector Expanded figure of part A in 6 When the GOTs with the following hardware versions are used remove the cable from an insulation sheet for protecting cables GT1562 VNBA Hardware version S to AT GT1562 VNBD Hardware version K to AH Insulation sheet for protecting cables GT1562 VNBA Hardware version AU or later GT1562 VNBD Hardware version AJ or later Insulation sheet for protecting cables 7 Remove the cables from the 2 slits black Expanded figure of part B in 6 VL 8 Press the backlight fixing latch black with your finger and pull out the backlight to the left 9 Mount a new backlight in the reverse procedure of removal When the GOT with the insulation sheets for protecting cables is used place the cable between the in
9. sulation sheet and an insulation sheet for protecting cables When connecting the cable connector of the backlight to the GOT side connector connect it as shown below The following figure shows an example with the insulation sheets for protecting cables A Insulation sheet SoS 7 for protecting cables atc Also assemble the case in the reverse procedure of disassembly Tighten the GOT rear fixing screws within the torque range of 0 36 to 0 48Nem When mounting the case take care of not biting the cables between the case and the GOT BACKLIGHT REPLACEMENT PROCEDURE FOR THE GT1165 VNBA C When using a GOT of model name GT1165 VNBA C replace the backlight with the following procedure 1 Power off the GOT 2 Disconnect the power supply cable and communication cable Remove the GOT from the control panel 3 Remove the GOT rear fixing screws 8 pcs with a screwdriver 4 Open the battery cover and remove the case with passing the battery through the hole of the case Only when a battery is mounted When removing the case take care not to detach the battery cable from the board Expanded figure of part A in 3 5 Disconnect the cable connector of the backlight from the GOT side connector 6 Remove the cables from the 2 slits black 7 Press the backlight fixing latch black with your finger and pull out the backlight to th
Download Pdf Manuals
Related Search
Related Contents
Secretaria de Estado da Educação LISTA DE MATERIAL Klip Xtreme KNC-250 8500695D 966PB-200X Profibus RTD Input User`s Manual Polaroid Mio Instant Camera Feuille de salle - Les Subsistances Sony STR-SL7 User's Manual Emtec CD-R Gold Digital Photo Manual - GAMING :: TrekCore Samsung SPF-83H Kasutusjuhend Copyright © All rights reserved.