Home
        USER MANUAL ORDER CODE: CONT05 PC
         Contents
1.    e Do not switch the equipment on and off in short intervals  as this will reduce the  system s life    e Only use the equipment indoors    e Do not expose to flammable sources  liquids or gases    e Do not carry the unit with only one handle  Always carry using both handles    e Always disconnect the power from the mains when equipment is not in use or before  cleaning  Only handle the power cable by the plug  Never pull out the plug by pulling the  power cable    e Make sure that the available voltage is between 220v 240v    e Make sure that the power cable is never crimped or damaged  Check the equipment and  the power cable periodically    e If the equipment is dropped or damaged  disconnect the mains power supply immediately   Have a qualified engineer inspect the equipment before operating again    e If the equipment has been exposed to drastic temperature fluctuation  e g  after  transportation   do not switch it on immediately  The arising condensation might damage  the equipment  Leave the equipment switched off until it has reached room temperature    e If your product fails to function correctly  discontinue use immediately  Pack the unit  securely  preferably in the original packing material   and return it to your Prolight dealer  for service    e Only use fuses of same type and rating    e Repairs  servicing and power connection must only be carried out by a qualified  technician  THIS UNIT CONTAINS NO USER SERVICEABLE PARTS    e WARRANTY  One year from date o
2. Acm      EFFECTS LTD     PC 08 Effects Controller       ORDER CODE  CONTO5    USER MANUAL    www prolight co uk    WARNING    FOR YOUR OWN SAFETY  PLEASE READ THIS USER MANUAL CAREFULLY  BEFORE YOUR INITIAL START UP     CAUTION     Keep this equipment away from rain   moisture and liquids        SAFETY INSTRUCTIONS    Every person involved with the installation  operation 4 maintenance of this  equipment should      Be competent     Follow the instructions of this manual    CAUTION  TAKE CARE USING THIS EQUIPMENT     HIGH VOLTAGE RISK OF ELECTRIC SHOCK         Before your initial start up  please make sure that there is no damage caused during  transportation  Should there be any  consult your dealer and do not use the  equipment     To maintain the equipment in good working condition and to ensure safe operation  it is necessary  for the user to follow the safety instructions and warning notes written in this manual     Please note that damages caused by user modifications to this equipment are not  subject to warranty     IMPORTANT     The manufacturer will not accept liability for any resulting damages caused  by the non observance of this manual or any unauthorised modification to the  equipment     e Never let the power cable come into contact with other cables  Handle the power cable  and all mains voltage connections with particular caution    e Never remove warning or informative labels from the equipment    e Do not open the equipment and do not modify the equipment 
3. f purchase     OPERATING DETERMINATIONS    If this equipment is operated in any other way  than those described in this manual   the product may suffer damage and the warranty becomes void     Incorrect operation may lead to danger e g   short circuit  burns  electric shocks   lamp failure etc     Do not endanger your own safety and the safety of others   Incorrect installation or use can cause serious damage to people and property        Operation  Technical Specifications   The unit has been designed to independently switch ON OFF up to eight lighting fixtures via the    power sockets at the rear  Simply plug each unit into the appropriate socket using the correct power  Power 230V 50Hz AC    plug and away you go   15A  with suitable connector   13A  with UK mains plug     For your protection the Effects controller has been fitted with a 15A circuit breaker which will Circuit Breaker 15A Reset switch  disconnect the main power supply to the outputs should you either overload the unit or if there is a Power Outlets 8 x 230V  1 OA  3 pin IEC female    Load Capacity    power surge  In such circumstances it is necessary to press the reset button to Dimensions 480 x 50x 127mm    re activate the power to the controller  Please turn off all 8 switches prior to pressing the reset button  Weight 2kg       Installation   Mounting   This Controller may be used either seated on a level surface or mounted into an appropriate  19  rack cabinet  For reasons of safety it is best to secure 
4. the unit into a rack or    a Suitable mounting so that cables cannot be pulled out of the panel     Overview     Channel Switches    Circuit Breaker Switc 19    Rack Mount    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Télécharger le dossier de presse  Connecting the Iomega StorCenter px4-300r  Liebherr 7081 225-00 User's Manual  Reba Service Manual  AMNIOSCOPIO ESTÉRIL DE UN SÓLO USO  ELCART  警告 注意 注意 - Azbil Corporation  Flo-tech Activa Sensor Arrays Manual PDF  KISS 2U Short V2  www.kegel8.co.uk USER GUIDE    Copyright © All rights reserved. 
   Failed to retrieve file