Home
User Manual - Transition Networks
Contents
1. 4 10 100TX 1 100FX Industrial Switch more suitable for harsh environments 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT Wide Operating Temperature The operating temperature of the 4 10 100TX 1 100FX Industrial Switch supports the wide operating temperature in the range between 40 75 C With such a wide range you can use the 4 10 100TX 1 100FX Industrial Switch in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and Fault help you diagnose immediately 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT Features Provides 4 x 10 100TX Mbps Ethernet ports Provides 1 SC ST fiber optic port TX ports support full half duplex flow control Supports MDI MDI X auto crossover Supports surge EFT protection 3 000 for power line Supports 6 000 Ethernet ESD protection Provides broadcast storm protection Embedded switch controller supports auto negotiation Supports store amp forward transmission Supports redundant 12 48 power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperatures from 40 75 C 24 Hour Technical
2. Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks Technical Specification SISTF101X 241 LRT The technical specifications of the Industrial Switch are listed as follows Communications Compatibility LAN Transmission Distance Transmission Speed Broadcast Storm Rate Limit Interface Connectors LED Indicators Power Power Consumption 24 Hour Technical Support 1 800 260 1312 IEEE 802 3 802 3u 802 3x 10 100Base TX 100FX Multi Mode Fiber 2KM 50 125um 62 5 125um Single Mode Fiber 30KM 9 125 UTP STP up to 100 meters Up to 100 Mbps 200pps 100Mbps 20pps 10Mbps 4 x RJ 45 1xSC orST type 100M fiber 6 pin removable screw terminal power amp Relay Unit P1 P2 Fault Ethernet port Link Active Full Duplex Collision 4 10 100TX 1 100FX model 4 44 Watts max International 00 1 952 941 7600 Transition Networks Power Input Fault Output Mechanism Dimensions WxHxD Enclosure Mounting Protection ESD Ethernet Surge EFT for power Power Reverse Environment Extend Operating Temperature Operating Humidity Certifications Safety EMC 24 Hour Technical Support 1 800 260 1312 SISTF101X 241 LRT 2 x Unregulated 12 48 Vpc 1 Relay Output 30 x 95 x 140 IP30 Metal shell with solid mounting kits DIN rail Wall Mount 6 000 Vpc 3 000 Vpc Yes 40 75 C 40 F 167 F 596 95 non condensing UL508 cUL CE EN6
3. port 100FX Industrial Switch 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT Top View The top panel of the 4 port 10 100TX 1 port 100FX Industrial Switch is equipped with one terminal block connector for the two power inputs and Fault Relay output Top Panel of the 4 port 10 100TX 1 port 100FX Industrial Switch 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT LED Indicators There are a few LEDs which display the power status and network status located on the front panel of the Industrial switch each of them has its own specific meaning as the table below LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive Fault Red i Power input 1 and 2 are both active or no power input Link Active On Connected to network 1 5 for 1 x 100FX Green Flashing Networking is active Off Not connected to network On Ethernet port full duplex Full Duplex Collision Flashing Collision of packets occurs Orange 1 4 di Ethernet port half duplex or not connect to network 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks Ports SISTF101X 241 LRT RJ 45 ports Auto
4. 0950 1 Class1 Division 2 FCC Class A International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 4 11 Voltage DIP CE EN61000 6 2 CE EN61000 6 4 ESD RS EFT Surge ee ee ae a ae Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Packing List 1x 4 port 10 100TX 1 port 100FX Industrial Switch User manual m 2x Wall Mounting Bracket and Screws Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Safety Precaution Attention IF DC voltage is Supplied by an external circuit please use protection device on the power supply input 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Hardware Description In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the 4 port10 100TX 1 port 100FX Industrial Switch is shown as follows LED Indicator 100Base Fiber Port LED Indicator 100Base RJ 45 Po Front Panel of the 4 port 10 100TX 1
5. 1 LRT Overview Introduction The 4 10 100TX 1 100FX Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications High Speed Transmissions The 4 10 100TX 1 100FX Industrial Switch provides you with Fiber port for your fiber optic cable to make a long distance connection The 4 10 100TX 1 100FX Industrial Switch includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted Dual Power Input To reduce the risk of power failure the 4 10 100TX 1 100FX Industrial Switch provides 12 48 dual power inputs If there is power failure 4 10 100TX 1 100FX Industrial Switch will automatically switch to the secondary power input Flexible Mounting 4 10 100TX 1 100FX Industrial Switch is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection The power line of 4 10 100TX 1 100FX Industrial Switch supports up to 3 000 EFT protection which secures equipment against unregulated voltage and makes systems safer and more reliable Meanwhile 6 000 ESD protections for Ethernet ports make
6. 4 port 10 100TX 1 port 100FX Industrial Switch User Manual SISTF101X 241 LRT T 1 00 Oct 2010 Transition Networks SISTF101X 241 LRT FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures W Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 24 Hour Technical Suppo
7. MDI MDIX The RJ 45 ports are auto sensing for 10Base T or 100Base TX devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as below for straight through and crossover cable schematic RJ 45 Pin Assignments Pin Number Assignment 1 2 3 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT Switch Router or PC 3 TD4 3 RD 6 TD 6 RD 1 RD 4 1
8. TD 2 RD 4 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD RD 2 RD 2 RD Cross Over Cable Schematic m Fiber Port The fiber connector can be worked in multi mode 2Km or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally SC Connector Cable Wiring SC to SC Tx A Rx TR Rx 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101 X 241 LRT ATTENTION ATTENTION This is a Class 1 Laser LED product Don t stare into N ihe Laser ED Beam Cabling Use four twisted pair Category 5 cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using single mode connector type must use 9 125um single mode fiber cable User can connect two devices in the distance up to 30 Kilometers Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Wiring the Power Inputs Please follow the steps below to insert the power wires V V V V 1 Insert the pos
9. itive and negative wires into the V and V contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent the wires from coming loose 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 14 Transition Networks SISTF101X 241 LRT Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status which the power is failure or port link failure for managed model and form an open circuit Note The wire gauge for the terminal block should be in the range between 12 24 AWG 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch at the factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw on the DIN Rail on the industrial switch 2 remove the DIN Rail reverse the step 1 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT 3 Insert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail i
10. ps 1 Unpack the Industrial switch packing 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning 7 When all connections are all set and LED lights all show in normal the installation is complete 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 20 Transition Networks SISTF101X 241 LRT Troubleshooting m Verify that you are u
11. rt 1 800 260 131 International 00 1 952 941 7600 POC WANG seende 1 Mark V ARMING cites cttancantacenninannchimeimesenabemeetdas 1 1 1 High Speed Transmissions 1 REI Hs 1 Flexible Mounting PERRO to 1 Advanced PIODGOUDI 1 Wide Operating 2 Easy Aviso giorno EHE 2 BV PRSE 3 Technical Specification 4 xe XR m n 7 Safety Precaution iiia 7 Hardware Description 8 FOM Panel eT 8 TN 9 LED IndibcalofS soc rae n ERE pa E 2I EPA REST dus 10 Transition Networks SISTF101X 241 LRT d T MNT 11 13 Wiring the Power 14 Wiring the Fault Alarm Contact 15 Mounting Installation 16 DIN Rail Mounting esses 16 Wall Mount Plate Mounting 18 Hardware Installation 19 installation SIOPS iannis 20 Troubleshooting 21 24 Hour Technical Support 1 800 260 131 International 00 1 952 941 7600 Transition Networks SISTF101X 24
12. s tightly on the track 6 remove the industrial switch from the track reverse the steps above 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the top amp bottom side of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 the wall mount plate reverse the steps above 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Hardware Installation Below is an illustration of some typical applications for the 4 port 10 100TX 1 port 100FX Industrial Switch Data collect server Human Management Interface Enterprise Switch Industrial Industrial Industrial Switch Switch Switch Sr wn Field Management Distribute 1 0 Programmable control system logic controller Device Server Field Automatic device Field Automatic device Field Automatic device 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF101X 241 LRT Installation Ste
13. sing the right power cord adapter Please don t use the power adapter output higher than the power input of this switch or it may damage the switch m Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections or 100Q Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions F the power indicator does not light on when the power cord is plugged in may have a problem with power cord Then check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance Ifthe LED indicators are normal with the correctly connected cables and the packets still cannot transmit please check your system s Ethernet devices configuration or status 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 21
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi pour la Saisie des Visites sur Net Mode d`emploi 2013 healthy living owners manual.indd Liste des produits et tarifs Uniden CAM650 Owner's Manual オートフラッシュCタッチスイッチ用 黒プレート A-4974 Instructions - Horizon Hobby Invacare® Storm³ Competition / FFH Copyright © All rights reserved.
Failed to retrieve file