Home
User manual CuroCell® AREA
Contents
1. e Turn the back to the patient and look in the moving direction e Hold one hand on the stair handle and pull with the other hand on the middle handle of the mattress e Walk down the stairs It is important to maintain speed without running Training practise To bear in mind when training Pulling down from the bed e The patient in the bed should not be at the very top of the mattress There could be a risk of hitting the head in the bed when pulling down Pulling in the stairs e Start with pulling an empty mattress down the stairs in order to practice the technique e When training with a person on the mattress a string or rope can be fasten in the handles at the head end Another person can then walk behind the mattress and help out if problems should occur e It is advisable to practice in the same stairs where an evacuation can be necessary General e The main purpose of the training is not to reach high speed but to learn the correct technique Training covers e Because of the heavy strain on the equipment when evacuating always check the seams and handles at the end of training We recommend that equipment used for training is marked with Training equipment and is only used for this purpose Explanations e If the Velcro straps are not used there is a risk of the patient sliding rolling down from the mattress e Pulling at the foot end reduces the strain on the puller which means faster and safer eva
2. Care of sweden Supporting Life User manual 2015 08 12 CuroCell AREA Self adjusting pressure care mattress User manual item number 95 001222 7 331345026442 CE Contents Important safety precautions Introduction Product description Instruction for use Cleaning and reconditioning Storage Troubleshooting Technical description Spare parts Options and accessories Warranty Other information Oo wo A WwW 10 11 11 11 13 14 15 15 IMPORTANT SAFETY PRECAUTIONS Read all instructions prior to use ae a ee a a a Ne ee ee WARNING 1 The product must only be used for its intended purpose as described in this manual The product may not be combined assembled or repaired with other parts accessories or spare parts other than those described in this manual or other documentation from Care of Sweden 2 The mattress are protected with a hygiene cover Please try to avoid the simultaneous use of multiple hygiene cover with this mattress Because of the risk vapour permeable can be destroyed 3 DO NOT USE in the vicinity of or in contact with fire sources hot surfaces such as fire burning cigarettes or hot lamps Although the product has undergone fire testing it could become damaged if it comes into contact with fire sources 4 Position and use the product in a manner that prevents it from becoming trapped or damaged NOTE Be particularly aware o
3. evac For the Evac function the maximum user weight is 130 kg We recommend that position changes are made regularly The time interval must be evaluated by the responsible personnel depending on the patient s status diagnosis and general condition The mattress must always be cleaned between patients NOTE e When used together with positioning pillows read the pillow user manual carefully for correct positioning of the patient e f you are using this product with an evacuation sheet it is the user s responsibility to ensure that it is safe to use for evacuation Be careful when using bed rails or other protection on the bed so that the mattress does not become crushed or damaged e The mattress must not be lifted with a person lying on it or used for any other type of transport other than a possible evacuation using an evacuation sheet e This mattress is unsuitable for use during x ray examinations because of the risk of blurred images or artefacts that may lead to diagnostic errors NEEN a s est al es sna EEEE ec er eae EEE E EE E E E 1 National Pressure Ulcer Advisory Panel European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance Prevention and Treatment of Pressure Ulcers Quick Reference Guide Emily Haesler Ed Cambridge Media Osborne Park Western Australia 2014 1 3 Evacuation instructions Evac is a mattress cover with a built in function for evacuation of bed bound users In case
4. 4 1 Label Head end 2 Foam core 3 Tubing system 4 Air cells 5 Foam top part CuroCell AREA 3 4 1 Label for Head end 2 Foam core 3 Tubing system 4 Air cells 3 Instruction for use 3 1 Unpacking the mattress The mattress is packed in a box 1 Start with making sure that the package is not damaged When opening the box and any other protective material avoid using a knife since this could damage the mattress and cover 2 Put the mattress on the bed frame and correct the cover if necessary 3 After a few minutes the product is ready to be used 3 2 Hand check Hand check is used to ensure that the function of the mattress is correct This should be done regularly Open the cover and insert your hand between the air cells directly underneath the user s pelvic region use a vertical hand There should be a clearance of 2 3 fingers between mattress base and the patient If not you need to check cells and tubing If the problem is not resolved please contact Care of Sweden or your local dealer 4 Cleaning and reconditioning It is important to follow the instructions below before using the product for a different user Consult the hygiene responsible or the supplier for help and instructions when unsure NOTE Check the hygiene cover each time the product is cleaned If damaged it must be replaced or repaired 4 1 Covers MATTRESS COVER Covers can be wiped off with a mild cleaning solution
5. Complete cover Art no 461 080200 461 080210 461 085200 461 085210 461 090200 461 090210 461 105200 461 105210 461 120200 461 120210 Art No CC 928255 CC 928256 CC 928257 CC 928258 CC 928259 Steel Evac Art no CC 925940 CC 925941 CC 925942 CC 925943 CC 925944 CC 925945 CC 925946 CC 925947 CC 925948 CC 925949 Size 90x210 cm 105x200 cm 105x210 cm 120x200 cm 120x210 cm Stone Evac Art no CC 925862 CC 925864 CC 925866 CC 925868 To ensure the best level of comfort we recommend use of accessories from Care of Sweden since our products are designed to work well together Please contact Care of Sweden or your local dealer for accessories or more information on our products 14 10 Warranty 10 1 Scope This CuroCell system is covered by a 5 year warranty for manufacturing defects The warranty does not apply to normal wear and tear or product impairment or damage stemming from negligence or improper handling care 10 2 Service and repairs Service and maintenance must always be performed by Care of Sweden or one of its authorised technicians Only use spare parts that have been approved by Care of Sweden Use of non approved spare parts invalidates the warranty A warranty claim must be submitted to Care of Sweden before the product is returned Please contact Care of Sweden or your local dealer if you have questions regarding warranty and service 10 3 Life expectance This pro
6. of fire or other emergency there is no time to think about what to do next Therefore it is very important that the safety equipment as well as the evacuation procedures are well planned and known in advance The Evac cover is equipped with three handles on the head and foot end On the sides there are handles with Velcro straps These straps are to be used to fixate the user to the mattress before commencing the evacuation The straps are folded in the protective pockets on the side of the mattress with the ends sticking out to ensure that they are easy to pull out WARNING Person to perform an evacuation needs to have the necessary training Always check the equipment cover and mattress before commencing to make sure an evacuation can be carried out safely It is the user s responsibility to ensure that it is safe to use for evacuation Evacuation instructions Down from the bed e Inform the patient about what will happen e Lower and lock the bed in position e Disconnect the tubes from the pump e Pull out and fasten the Velcro straps e Use the outer handles at the foot end of the mattress and turn the mattress out from the bed e Slowly pull the patient down on to the floor On an even surface e Pull on the outer handles at the foot end of the mattress e Working position should be a little bit leaning back Down the stairs e Walk backwards until the main part of the mattress has slide pass the top stair
7. or electricity The system uses patient weight and movements to distribute the internal air reservoir amongst the cells in order to always maintain low surface pressure The CuroCell AREA are available in three different models all produced in high quality materials for function and durability CuroCell AREA Original design The foam part is in one piece CuroCell AREA Zone Foam part in two layers Zone profiled top part CuroCell AREA Soft Foam part in two layers top part in viscoelastic and HR foam All mattresses have a sloped heel section for protection of heels Available sizes are width length and height 80 85 90 105 120 x 200 210 x 18 cm For request of other sizes please contact Care of Sweden or your local dealer 2 1 Description covers CuroCell AREA is delivered with hygiene cover Steel It is easy to handle and maintenance and get through highly set requirements of cleaning and hygiene The cover is vapor permeable which reduces risk of skin maceration An inner cover protects foam and cells Cover Steel is a two part cover with welded seems and a protected zipper Has functional handles for transportation of the mattress Colour blue black An inner cover is also included Evac cover A cover with protected zipper on all sides divisible top and bottom part Functional handles for evacuation moving and transport Colour grey black 2 2 Description mattress CuroCell AREA Zone CuroCell AREA Soft
8. specification at any time WARNING Follow the operations and maintenance instructions carefully in order to prevent bodily injuries as well as damages to the product or other equipment 7 2 Labelling The mattress is labelled with product name production date article number size care and wash instructions EAN bar code as well as space for own labelling The product also displays which side is up down and head foot 11 7 3 Symbol Definitions Article No Manufacturer GROY LINNA 39 OLN 7 O Ynna Read the user manual Group of function Dx Br Not in domestic refuse Recommended user weight follow recycling instructions arza 0 130kg Recommended user weight when using Evac function Counteract shear force A Machine wash at 95 C lt 1 Chlorine Drip dry Do not iron o Class II equipment Type BF Double Insulated N The mattress should only be used lying in the lengthwise direction on the mattress 12 XXXX XX XX Year Month Day CE CE marked acc to MDD 93 42 EEC Category Patient information category po Heel function O umble dry Do not dry clean IP__ IP class Ingress Protection Rating Foot placement ye Y a Recycling ioe Directly on bed base TI Do not wash Res Do not tumble dry Temperature range 8 Spare parts Cover Steel Steel and Stone Steel for CuroCell A
9. REA Zone Top part Steel Top part Stone Bottom part Steel Size Art no Art no Art no 80x200 cm CC 925511 CC 925581 CC 925011 80x210 cm CC 925512 CC 925582 CC 925012 85x200 cm CC 925513 CC 925583 CC 925013 85x210 cm CC 925514 CC925584 CC 925014 90x200 cm CC 925515 CC 925585 CC 925015 90x210 cm CC 925516 CC 925586 CC 925016 105x200 cm CC 925517 CC 925587 CC 925018 120x200 cm CC 925519 CC 925589 CC 925019 Art no Description Size cCcC 900050 Air cell AREA 1 pcs 63x15x12 cm If other spare parts are needed please contact Care of Sweden or your local dealer for further assistance 13 9 Options and accessories 9 1 Options Sturdy transport and storage bag Art No 58 900905 58 900906 58 900911 Description Mattress bag Mattress bag extra high Mattress bag extra high 9 2 Accessories Width 105 120 cm 80 90 cm 105 120 cm Cover Steel Evac and Stone Evac for CuroCell AREA Zone Top part Steel Top part Stone Art no CC 925586 CC 925587 CC 925588 CC 925589 Size Art no 80x200 cm CC 926110 80x210 cm CC 926111 85x200 cm CC 926112 85x210 cm CC 926113 90x200 cm CC 926114 90x210 cm CC 926115 105x200 cm CC 926116 105x210 cm CC 926117 120x200 cm CC 926118 120x210 cm CC 926119 Inner cover elastic for CuroCell AREA Zone Art No Size CC 928250 80x200 cm CC 928251 80x210 cm CC 928252 85x200 cm CC 928253 85x210 cm CC 928254 90x200 cm 9 3 Other accessories Bottom part Evac Complete cover
10. ch as alcohol withor without tensides Isopropanol 70 oxidating solutions or chlorine max 1 5 Replace the cells into the cell holder Place the air cells back into the foam core Check that all the tubes and connectors are secure and tight before closing the cover 10 6 Wipe off work surfaces with alcohol based disinfectant cleaner intended for this purpose If cells for any reason have loosened from the tubes these must be replaced according to drawing in chapter 2 1 5 Storage Store the mattress on a flat surface or carefully rolled folded with the zipper closed Always store at room temperature in a dry area Make sure the mattress is stored where it will not be exposed to thrusts hits or other things that can damage it Avoid direct exposure of sunlight If the mattress is to be stored more than 3 months we recommend it is stored on a flat surface not folded or rolled up 6 Troubleshooting Problem Solution The patient is bottoming out Open covers and check cells and tubing Check again through Hand check see chapter 3 2 If your questions are not answered by information above please contact Care of Sweden or your local dealer 7 Technical description 7 1 Technical specification MATTRESS SPECIFICATION CuroCell AREA CuroCell AREA Zone CuroCell AREA Soft Dimension WxLxH 80 85 90 105 120 x 200 210 x 18 cm 16 kg 90x200x18 cm NOTE The manufacturer retains the right to modify the product
11. cuation is possible e Pulling in the stairs is the most difficult part of the evacuation and should be practiced extra carefully e The arms of the patient shall be inside of the Velcro straps This way reduces the risk of the user grabbing hold to something out of fear NOTE There is a difference in maximum user weight between use of the Mattress and use of the Evac function Please read section 1 2 for more information To ensure proper function of the Evac cover it is important to regularly check the quality of the mattress Check for damages that could cause problems when evacuating 1 4 Other information Action plan Pressure ulcers To achieve the best possible result for this product it is recommended that a well planned and well structured working environment be used In our guideline Action plan you will find examples which can be applied and put into practice when using our products Mattress guide This practical guide gives you as a care giver help in choosing the correct mattress from the Care of Swedens range CuroCell AREA is a mattress in function group B This information can be found on our website www careofsweden com or you can order a copy from our Customer services by sending your details to info careofsweden se 2 Product description Because of its unique construction combining foam and air this mattress provides high user comfort as well as a solution for pressure care without the need for external pump
12. duct s expected life is estimated to be 5 years 11 Other information 11 1 Disassembling and recycling A used CuroCell mattress must be taken to a recycling centre and sorted as combustible waste For more information contact Care of Sweden or your local dealer 15 Manufactured by Care of sweden Supporting Life Contact Phone 46 771 106600 Fax 46 325 12840 Email info careofsweden se Internet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns vag 4A SE 514 33 Tranemo SWEDEN Supplied by Care of Sweden and CuroCell are trademarks of Care of Sweden AB Care of Sweden AB 2015 16
13. f trapping damage when using bed rails 5 Always make sure the mattress has the right size 6 The hygiene cover does not allow liquid or air to penetrate but is vapor permeable Make sure that the patient is positioned correctly to avoid the risk of suffocation 7 Prevent damage to the hygiene cover from sharp objects 8 Ifthe cover are supplied with handles on the long sides theses handles are only to be used for lifting and moving the mattress itself All other use will be at your own responsibility and is not covered by the product warranty 1 Introduction i Always read the user manual prior to use 1 1 General information This CuroCell mattress is a medical device in accordance to MDD 93 42 EEC According to statutory regulations made by the authorities regarding medical devices the manufacturer is required to report all accidents or incidents involving there products We would be very grateful for all information involving accidents or incidents relating to our products by reporting them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards SS EN ISO 12182 SS EN ISO 14971 SS EN ISO 10993 EN 597 1 EN 597 2 EN 14126 1 2 Intended use CuroCell AREA is a replacement mattress that can be used in a range of health care environments to prevent pressure ulcers as well as treatment up to and including category 3 The recommended user weight is 0 230 kg
14. for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Excrements and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner 7 O u Bat RI Multi layer covers should be divided before washing Wash with similar colours Chlorine and phenol based cleaners could have a negative impact on the PU surface lt 1y and should be avoided If chlorine is used we recommend a mixture of max 1 INNER COVER 87 Q ll Bet Bi Clean the affected area with a mild cleaning solution for this purpose such as alcohol with or without tensides Ilsopropanol 70 oxidating solutions or chlorine max 1 4 2 Foam core Clean the affected area with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Press out the water carefully Let the foam core dry in a warm ventilated area without direct exposure of sunlight The foam core needs to be completely dry before it is used again 4 3 Air cells 1 Remove the covers See instructions in chapter 4 1 for cleaning covers 2 Carefully remove the air cells from the foam core Remove the cell holder from the cells 3 Place the air cells and the tubes on a clean area which is suitable for washing 4 Wipe off the cells all tubes with a mild cleaning solution for this purpose su
Download Pdf Manuals
Related Search
Related Contents
faça do MANUAL DE UTILIZAÇÃO DO SILO Manual del Usuario de FlowGo [くらし応援室(大)]総括表(PDF形式:26KB) User Manual Doro PhoneEasy 336w Screenlife Scene It? Disney Bingo User's Manual OMRON - Documentation: E3S-DB - Cellules Bedienungsanleitung - LTT Spiker PH 539M Manual de usuario 2 - PHC-Online.com Copyright © All rights reserved.