OPERATION MANUAL

image

Contents

1. You must cut off power supply of indicator before pulling out connecting line of load cell 7 7 During operation if trouble occurs operator must pull off the power supply plug immediately and user should return this indicator to our company for repair Non weighing manufacturer should not repair it or by yourself otherwise further destruction may happen 7 8 The storage is not granted the free repair guarantee because it is easily exhausted products In order to prolong using life please charge the cell fully before using it If you don t use the indicator for a long time you must charge the cell every two month and for eight hours each charging time Moving or installation must be carefully taken and must avoid strong vibration impact and bump in order to protect the storage cell from being damaged 7 9 From invoice date the indicator has a one year free repair period If any non artificially obstacle about the indicator happens under correct using conditions within this period the user is allowed to send the product with its guarantee card of the correct number back to our corporation for free repair The indicator shouldn t be taken apart otherwise free guarantee will be cancelled
2. 11 indicator will display the weight of loaded weight Input the actual weight of 3000 m loaded weight Press to step 13 if the inputted Eg 3000 weight is as same as the loaded weight 12 Press three times to change the value to 3 and then press for confirmation bt Baud rate Indicator displays the 13 original baud rate parameter which can be updated by operator 14 Calibration is over exit to weighing mode ERRORO ERROR1 ERROR2 ERROR 3 HHHHHH LLLLLLL Chapter 5 Error Indication The zero inner code is over 260000 when calibration The loaded inner code is less load cell capacity is more The loaded inner code is more load cell capacity is less Calibration exceeding The zero lever is too high or load on the platform The zero lever is to high or no pan on the platform Chapter 6 Chargeable Battery 6 1 Turing on the AC power the indicator will charge the battery automatically So if you don t use battery frequently you should take battery out Note red end is black end is Wrong connection will destroy indicator Note The built in battery should be fully charged before it is used for the first time 6 2 Only when you turn off the AC power and push start key battery works Displaying LouoL means the insufficient of voltage it needs charge 6 3 When you use the battery first time you should charge the batter
3. 1 Front and back view of the indicator AC HOLD ACCUM STABLE TARE ZERO Front View of the Indicator Load cell socket Power line Back View of the Indicator 2 2 Connecting load cell to indicator The 9 pin plug is for load cell please connects the line as following graphs End of Indicator End of load cell V Stimulating Power Supply V Shield V Stimulating Power Supply IN Signal Output ph Signal Output GShield lt Connection of load cell You must cut off power when connecting load cell the connection must be reliable After connecting load cell you should fasten plug with screw driver Load cell and indicator are static sensitive devices you must adopt anti static measures during operation You must mount lightening rod in thunderstorm frequently happening area 2 3 Serial Communication Interface Optional 1 Indicator communicate with computer by serial communication interface 2 Connection Indicator communication interface adopts 5 pin plug pin definition is as follows 5 pin TXD signal serial communication data 1 pin ground line 2 pin shield line The communication interface is 2pin plug 1 pin signal serial communication line 2 pin ground line for communication 3 Parameter D Signal RS232C Baud Rate 1200 2400 4800 9600 Ref Chapter 4 Calibration 3 Data format Weight data including decimal ASCII Code The l
4. OPERATION MANUAL Edition Month year hed October 2003 June 2004 f 7 7 4 o Em Table of Contents Chapter1 Main Specification 8MBMMMM8ee oe ue installation j gt h _ ee SR Ra aa aaa Front and Back View Of NOICAIO 7000222203ssaadasaddasaisbaaaasadddaaa saaadasaddanassa Connecting Load Cell to Indicator 22200nnnnnnnnnnnnnanaaaaaaaaaaaaaaaaaanaaaann Serial Communication Interface Optional Chapter3 Operation Meesfee e Chapter4 Calibration M88MMee Chapter5 Errors Indication MMMeeeeee444 Chapter6 Chargeable Battery MMMMeeee Chapter7 Maintenance MMeeeseeee Chapter 1 Main Specification Analog Input Signal 0 10mV Converting Speed 40 times second A D code 360000 Non linearity 0 0396 Drift 0 0396 Stimulating Voltage DC 5V Load Cell 1X 3500 Display Display 0 999999 Interval 1 2 5 10 20 50 optional Serial Communication Interface Optional Signal RS232C Transmission Distance lt 20m Ambient Environment Power Supply AC 220v 15 10 50HZ 2 2 Ambient Temperature 0 C 40 C Storing Temperature 25 C 55 C Ambient Temperature lt 85 RH Warm up Time 10 15minutes Fuse 500mA Weight 2Kg excluding battery Chapter 2 Installation 2
5. ow bit is prior to high bit and symbol Negative symbol is Positive symbol is 0 For example While indicator displays 500 00Kg serial output is 00 005 While indicator displays 500 00Kg serial output is 00 0050 Chapter 3 Operation 3 1 Turning on 3 1 1 Turn on the power the indicator performs self checking and displays current voltage of battery and go into weighing mode 3 2 Operation 3 2 1 Press Ekor zero return indicator returns to zero within the zero range 4 FS To make sure the stabilization light is on when zero operation 3 2 2 At weighing mode press Elo deduct displaying weight while it is positive and T stabilization light is on Indicator displays net weight 0 tare light is on press o deduct tare tare light is off indicator displays gross weigh 3 2 3 At weighing mode press L to enlarge the resolution of weight to 10 times Press hain to get back 3 2 4 At weighing mode press bo lock the weight value Holding light is on The weight value will be hold even if you take object off or put it on Press again to get back 3 2 5 Manual accumulation At weighing mode while the weight value is large or equal to 20 counts and the value is e stable press to perform manual accumulation operation Meanwhile indicator first shows the total accumulating times two steps n that means the times displaying after 1 second later it displays accumulating times and
6. peration display Explanation 1 77 Weighing display 2 F F P00000 Remind to input preset tare Press 3 Input preset tare eg 6000 6000 Press 6 times to change the lowest digit to 6 and then press 3 times to set the value as 6000 and press to confirm 4 are Turn back to weighing mode displaying the net weight of deducting tare 3 2 10 Automatic dormancy Indicator keeps at stable mode for 2 minutes and no any operating and weighing it will turn to automatic dormancy meanwhile the final decimal is lighted Any operating and weighing will arouse it to working mode 3 3 At calibration and preset tare mode some of the keys perform as follows 1 perform 1 adding press to add 1 on the lowest digit 2 perform moving press to move the lowest digit to left 3 perform inputting press to input setting value to the indicator 4 perform exiting press to exit calibration Chapter 4 Calibration 4 1 Turn on the indicator and connect load cell correctly the indicator warms up for 15 30 minutes at no load At weighing mode press Ae together for calibration 4 2 Calibration steps Step Operation Display Explanation 1 Weighing display Setting of interval indicator displays 2 Press d the original interval which can be updated by operator Input updated interval Eg 1 Parameter range 1 2 5 10 20 50 Press once to change 3 99 fd 1 Pre
7. ss Ll to confirm the updated the value to 1 ET one is as same as the original one Press for confirmation Decimal setting Indicator displays the original decimal position which can be updated by operator 4 JP Parameter range 0 5 0 means no decimal 1 5 separately means the decimal i osition from 1 5 5 Press three times to dP 3 p Input updated decimal Eg 3 change the value to 3 Press jo to confirm the updated Press for confirmation P one is as same as the original one F S setting indicator displays the 6 F original F S which can be updated by operator Input undated F S Eg 6000 Press six times to If there is no need for zero and F S 7 change the value to 6 and 6000 calibration press to step 13 then press three times otherwise you must input F S value to step 8 and 9 to move to 6000 press for confirmation Zero calibration indicator self checks the zero position provided indicator nloAd 79r Po h 8 didn t calibrated zero before it displays the zero inner code otherwise it go to step 9 LoAd FS calibration Zero position is confirmed you can load weights for 9 Nt the preparation of F S calibration that should be gt 1 2 of the F S Finish of weight loading Indicator displays the inner code of 10 the loaded weight press At the stabilization of the value
8. then to display the total value of accumulation two step totl that means to display the total value of accumulation after 1 second later it displays accumulating value accumulating light is on Note the max accumulation times are 99999 under the condition of accumulating amount lt 999999 Prior to the delete operation the accumulating amount is recorded even power off 3 2 6 Automatic accumulation e At weighing mode press 4E together indicator performs automatic accumulation and accumulating light flashes At automatic accumulation mode while the weight value is large or equal to 20 counts and the value keeps stable for 1 2 seconds indicator performs one time automatic accumulation displaying accumulation times and amount Note The accumulating amount is not recorded under automatic accumulating mode when power off 3 2 7 At weighing mode press to delete the accumulation times and amount 3 2 8 Kg lb diversion At weighing mode press together indicator performs unit diversion while the unit is Ib the final decimal of the displaying value is lighted Note once you operate accumulating and fail to delete the accumulation amount at one of the unit unit diverting is not allowed unless you delete the accumulation amount 3 2 9 preset tare T At weighing mode press together indicator performs tare presetting The procedure is as follows Step O
9. y for 20 hours in order to prevent low voltage resulted from the self leakage of the battery 6 4 If you don t use battery for a long time you should charge the battery for 10 12 hours for each 2 month to prolong using life of battery 6 5 The battery is easily exhausted products And it is not granted free guarantee Chapter 7 Maintenance 7 1 To guarantee indicator clarity and using life the indicator shouldn t be placed directly under sunshine and should be set in the plain space 7 2 The indicator can t be placed into the place where the dust pollution and vibration are serious 7 3 Load cell should connect with indicator reliably and the system should be well connected into ground The indicator must be protected from high electrical field and high magnetic field n order to protect the operator indicator and relevant device you should mount lightning rod in thunderstorm frequently happening area Load cell and indicator are static sensitive device you must adopt anti static measures 7 4 It is strictly forbidden to clean the case of indicator with intensive solvents for example benzene and nitro oils 7 5 Liquid and conducting particle should not be poured into the indicator otherwise the electronic components will be damaged and electric shock is likely to happen 7 6 You should cut off power supply of indicator and relevant device before you pull in and out the connecting line of indicator and external device