Home
Manual for Datalogic TCL-NET.
Contents
1. All parameters and folders can be selected by using either the stylus or the following keyboard keys Enter if pressed it validates the selection and allows saving the configuration when exiting the control panel Arrow Keys if pressed they allow scrolling all pages horizontally when the folder is selected Tab If pressed it allows scrolling each parameter of the selected folder ESC if pressed it exits the Control Panel without saving the configuration By exiting the DL TCL NET Control Panel the following dialog box appears allowing to exit to Windows CE NET DIE TEL NET 9 Exit to CE NET Figure 11 Exiting DL TCL NET The main setup menu is shared by all Datalogic RF mobile computers Different parameters will be signaled Text Mode Menu By pressing the SHIFT and ESC keys simultaneously FUNC and O for Datalogic Jet M mobile computer it is possible to enter the device configuration menu in text mode This menu allows setting DL TCL NET in order to manage extended color commands for VT emulation Use options 2 Emulation gt 2 VT100 200 gt 7 Color Default value is ON Datalogic SETUP I Host Login 5 Login Termination ji Command Execution Color DM Enter to continue Figure 12 VT Color Option 13 dy DL TCL NET If entering the text mode menu through the ftp password it is possible to start the internal TCL FTP Server Thus an FTP clie
2. Part RS232 ww DL TCL NET Control Panel OK x Connection Emulation Advanced Device Display i2 Display ala Scanner 4 Keyboard Host Controlled Beeper Upper Case wee Beep Duration ms ion y EM Beep F Hz 1000 a eep Frequency Hz Out of Range off gt HEH y Printer i Fort R5232 Figure 17 Device Menu Upper Case It enables disables the conversion of all barcode data and keyboard digits to upper case characters 22 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER Out of Range When configuring the radio the Out of Range option set AUTO allows DL TCL NET to automatically signal if during data transmission a mobile computer is out of the area covered by the Access Point For all devices this condition will be signaled by the LED activation while for Rhino NET the signal is emitted by the beeper If set to ON it is possible to verify this condition only if trying to transmit from the mobile computer In all these cases the following message is displayed Warning i OUT OF RANGE i Cancel Figure 18 Out of Range Warning When returning within the covered area the following message is displayed if the mobile computer cannot get the IP address immediately GET NETWORK CLONMEL TION Figure 19 Getting Mobile Computer IP Address Host Controlled Beeper It defines the beeper parameters activated by a host command Be
3. DL TCL NET User s Manual DATALOGIC DL TCL NET USER S MANUAL DATALOGIC DATALOGIC S p A Via Candini 2 40012 Lippo di Calderara di Reno Bologna Italy DL TCL NET Ed 05 2006 This manual refers to DL TCL NET software version 1 2 1 0 or later ALL RIGHTS RESERVED Datalogic reserves the right to make modifications or improvements without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic S p A 2003 2006 17 05 2006 CONTENTS m NNNN oO ND WWW WWW WO WW do M LL LI Ll NO UPU N A GENERAL INFORMATION nocaut d a ia iai 80 a ioana dia a d ta 1 LS Le ET Miss a RENT PRD SR NT MIR UO 1 INSTALLATION daa aaa cae a etn A via 2 System Requires 2 Installing DL TCL NET onto the Mobile Computer o oocccccocccncccccccnoccncnno 2 Starting DL TCL NET Cent scientie sce ta ea Da 26 Boa ai a n tal a 3 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 4 Main Setup MENU soc orto 12 Connection Menu nennen nennen nnns nnne a nnne ns 14 Emu ON Men TM 18 Advanced Melina 20 DEVICE Ma de ul 22 A ET 24 A DE TT 27 ADOUL PEN E NEC 0 lv e ach
4. ESC lt 0 1 gt f amp ESC lt 0 1 gt r amp ESC lt 0 1 gt g amp ESC lt 0 1 gt h amp ESC lt 0 1 gt i amp ESC lt 0 1 gt 1 amp ESC lt 0 1 gt m amp ESC lt 0 1 gt s amp ESC lt 0 1 gt n amp ESC lt 0 1 gt o amp ESC lt 0 1 gt p amp ESC 1x amp ESC 1y amp The lt 0 1 gt string indicates the two possible values where O disables the option and 1 enables it 35 DL TCL NET Other commands are provided in the following table for the scanner and keyboard management Function J mana The following table lists four commands to set the font type 36 TERMINAL EMULATION KEYBOARD OVERLAYS A TERMINAL EMULATION KEYBOARD OVERLAYS VIPER NET MOBILE COMPUTER The following images show the keyboard overlay of the Viper NET 32 key model for 3270 5250 and VT HP terminal emulation BAT Low CHARGER BAT Low CHARGER F9 A F17 F10 B F18 F11 C F19 F12 D F20 F9 A F17 F10 B F18 F11C F19 F12D F20 SCRLE PA1 F13 F F21 F14 G F22 EOF H PA2 SCRL E FLD F13 F F21 F14 G F22 SREOH RL ATTN I PA3 F15 J F23 F16 K F24 CLR LSREQ HELP I FLD F15 J F23 F16 K F24 RESETL RLW M N CAPSLK O M N CAPSLK O lt P gt 59028 R lt P gt Q R S VM ou 1 gt U n S VETUS _ U n V w X V P SCR W HOME F EXTX DUP o o AN a STAT Y DEL Z INS SPC BKSP E STAT Y ATTN DEL Z INS SPC BKSP co Lal 3270 Terminal Emulation 5250 Terminal Emulation 37 DL TCL NET BAT Low CHARGER F9 A F17 F1
5. ro rao rii riz ris er jros rus IA yg r17 r1s ri9 rn dus lalala KEYS F1 F20 VT Function Keys ESC Escape List Session List 1 4 Session Number OK Close VT Keypad 10 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d 3270 KEYPAD 3270 KeyPad Fo F10 F11 F12 F13 F14 F15 F16 F17 F18 F10 F20 F21 F22 F23 F24 ATTN SREO EOF RESET Session l i 2 a a KEYS F1 F24 IBM 3270 Function Keys EOF PA1 PA3 Program Attention RESET CLEAR Clear List ATTN Attention 1 4 SREQ System Request OK End of Field Reset Session List Session Number Close 3270 Keypad 11 dy DL TCL NET 3 1 MAIN SETUP MENU The DL TCL NET control panel opening mask appears as follows DL TEL NET Control Panel UR l Connection Advanced Host Host Mame IP ge mmm Host Port 23 Emulation vr220 v Keen Connecting KC 1 Name IP KC2Name IP KC3NamefIP KC4NamefIP Multiple Session ActiveSync RMT DL TCL NET Control Panel OK Connection Emulation Advanced Device Display 1 2 Display 2 2 Scanner Host Keep Connecting Host Mame IP Address ECL Name IP Address le 160 11 KC2 Name IP Address Host Port KC3 Name IP Address 23 a KC4 Name IP Address Emulation vT220 gt Multiple Session w ActiveSync Remote Remote Figure 10 Control Panel Opening Mask 12 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d
6. 220 IBM 5250 BM3270 KCn Name lP It defines the Network name or IP address for the n Keep Connecting KC gateways Multiple Session It defines the type of connection to be used by the mobile computer to interact with applications running both with direct connection on the remote Host and with the Keep Connecting gateway If unchecked the mobile computer works in Single Session Mode trying to connect to the first Keep Connecting gateway or remote Host available If checked the device works in Multiple Session Mode but in this case it can manage up to 4 different sessions simultaneously both with direct connection and with the Keep Connecting gateway DIRECT HOST CONNECTION Single Session Mode The Multiple Session parameter is set to off When the user connects by clicking on ENTER from the opening mask the HOST List is displayed and the user can choose to which host he wants to connect If only one host is configured the direct connection to it is made automatically Only one applications session at the same time is available to the user To open a different application session the user must before close the current one By pressing the ALT 0 keys in sequence or the button LIST in emulation keypads the program returns to the Host List allowing to change the application session the mobile computer is connected to The current application session is signaled in reverse video within the list Once a new applica
7. Datalogic Jet it is necessary to remap them properly by using the DL Mobile Director Local Configurator List Session Session 1 Session 2 Session 3 Session4 ActiveSync RMT ActiveSync Remote Click on this button to run the ActiveSync Remote application allowing the connection to the mobile computer through the DL Mobile Director Local Configurator 17 dy DL TCL NET 3 1 2 Emulation Menu It allows defining the emulation parameters DL TEL NET Control Panel Emulation Advanced gt General Device Mame Password E TCP KeepAlive Timeout 200 AutoRun a Log File d vT100 220 AddLFtocR Term Lagin DelTops ENTER w Lacal Echa a Line Mode 3270 5250 AUTO Reset Mode DL TCL NET Control Panel Connection Emulatian Device Display 1 2 Display 2 2 General Device Name a TCP KeepAliwe Timeoutts ano Password i AutoRun Log File VT 100 220 3270 5250 Add LF ta CR Termination Login ENTER y AUTO Reset Made DelToBs LocalEcho Line Mode Figure 15 Emulation Menu Device Name This parameter allows assigning a name to the mobile computer performing the connection By inserting an before the name i e Name the device name will indicate the device name in the AS400 protocol variable Device Name Password It allows creating or changing the password for entering the setup 18 DL TCL NET CONFIGURATION FROM M
8. the program sends an error message DL TCL NET OK x A Connection not available Figure 6 Error Message Press the Enter key or tap OK in the message box to return to the opening mask If the connection is successful the user is connected to the Host or Keep Connecting gateway During the connection the following special function keys are available Exit emulation by pressing the Exit Emulation Key the following dialog box is displayed allowing to quit the terminal emulation at any time and display the Opening mask Mobile Computer Key Sequence Rhino NET M F10 Viper NET F10 Datalogic Skorpio F10 Datalogic Jet F3 Kyman NET M F10 DL TCL NET 99 Exit from Emulation Are YOU sure Figure 7 Exit Emulation Dialog Box This procedure requires exiting all sessions see par 3 1 1 for details nput panel it allows enabling disabling the Windows CE NET input panel Mobile Computer Key Sequence Rhino NET ALT K Viper NET ALT K Datalogic Skorpio ALT K Datalogic Jet FUNC UP Kyman NET ALT K Kyman NET num model YELLOW UP Digital UNIX dlitux0 ime Digital UNIX dlitux01 dlit it ttyp3 Login mnneannnaaonmnec nnaugngouggog so Tab a w e r t v u i o p E 1 Tab porc Shift ETER EREI CACI CH COPI EZ cul a XT Dete ETE AA mU E E CYD Figure 8 Input Panel DL TCL NET CONFIGURATION FROM MOBILE COM
9. to all laser modules and allow controlling the scanning device File Parameter Window Help Scan Timeout au Beepburation 0 BeepFrequencyw 2000 LedDuration o LedPulses o ContinuousMode Disabled EevhoardEmula Disabled SoftTrigger Enabled Scan amp lwayson Disabled GoodReadSound Beep wav Scanner Setup lt scan Parameters M File Parameter Window Hel Scan Timeout BeepDuration BeepFregquencwy LedDuration LedPulses Continuousklode Enabled M e ll scanner setup lt Scan Parameters gt Figure 25 Scan Parameters The Scan parameters are Scan Timeout the maximum time in milliseconds during which the laser remains on without decoding any barcode Beep Duration the time interval in milliseconds during which the beeper will sound when the scanner reads a code To disable the beeper set this value to O Beep Frequency the frequency in Hertz of the beeper LED Duration the duration in milliseconds of each Good Read LED pulse 31 dy DL TCL NET LED Pulses the number of pulses the Good Read LED will blink when the scanner reads a code Continuous Mode if enabled the laser can only be turned off by releasing the hardware trigger or if Soft Trigger is enabled by the application program Continuous Mode overrides Scan Timeout Keyboard Emulation if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved into a file as if input fr
10. 0 B F18 F11C F19 F12D F20 SCRL E P SCR F13 F F21 F14 G F22 H HOME I BREAK F15 J F23 F16 K F24 L HOLD M N CAPSLK O S M T E U fo V W X STAT Y DEL Z INS SPC BKSP VT HP VT HP Terminal Emulation 38 TERMINAL EMULATION KEYBOARD OVERLAYS The following images show the keyboard overlay of the Viper NET 48 key model for 3270 5250 and VT HP terminal emulation AScrA VScrw L PA1 CLEAR ATTN gt F21 lt F22 F23 F24 F7 F17 F8 F18 F9 FA F14 F5 F15 F6 TAB Fl Fil F2 F12 F3 CAPSLK F10 F20 3270 CHARGER Scr 4 Scr PA2 _ PA3 SREQ EOF RESET F19 INS F16 DEL F13 STAT BTAB 3270 Terminal Emulation ROLLA ROLLY BAT LOw AScrA VScrw gt F21 lt F22 F7 F17 F4 F14 TAB F1 F11 CAPSLK IBM 5250 CLEAR ATTN F23 F24 F8 F18 F9 F5 F15 F6 F2 F12 F3 F10 F20 CHARGER Scr pScrp FLD _ FLD X SREQ F EXIT DUP RESET F19 INS F16 DEL F13 STAT BTAB 5250 Terminal Emulation 39 O DL TCL NET AScr A BAT Low E gt lt F7 F17 F4 F14 TAB Fl Fil CAPSLK VT HP F8 F18 F5 F15 F2 F12 F10 F20 CHARGER wScrw Scr 4 Scr F9 F19 INS F6 F16 DEL F3 F13 STATBTAB VT HP Terminal Emulation RHINO NET MOBILE COMPUTER The following image shows the keyboard overlay of the Rhino NET mobile computer 40 TERMINAL EMULATION KEYBOARD OVERLAYS
11. Application mask is displayed Then the user can choose the application running on the remote Host the Keep Connecting gateway is connected to and start working within it By pressing the ALT 0 keys in sequence or the button LIST in emulation keypads the program returns to the Applications mask allowing to change the application session the mobile computer is connected to The current application session is signaled in reverse video within the list Once a new application session is set the current one is automatically disabled and the mobile computer starts emulating a new application session If no change has been made press Enter to return to the current session 16 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d Multiple Session Mode The Multiple Session parameter is set to on The mobile computer works as in Single Session Mode but in this case it can manage up to 4 different session modes Mode 1 Mode 2 Mode 3 and Mode 4 at the same time It is possible to switch from one application to another by pressing the following keys in sequence or by pressing the proper button of VT or IBM keypads ALT 1 Mode 1 ALT 2 Mode 2 ALT 3 Mode 3 ALT 4 Mode 4 ALT 0 Returns to the Applications mask In this case the selection of a new application session causes the closure of the current one while the other applications sessions remain active If ALT key sequences are to be used with
12. ET through the PC installation method follow the given procedure 1 ensure that the Windows CE NET device is connected to the PC and synchronized with it 2 double click the setup exe icon on your PC and follow the instructions appearing in the dialog box below fi Add Remove Programs Select a program s check box if you want to install it on your mobile device or clear the check bos if you want to remove the program from your device Note If a program that you installed is not listed the program was not designed to be used on your mobile device Install Datalogic DL TCL for CE NET using the default application install directory No Annulla Space required for selected programs Space available on device IV Install program into the default installation folder Remove from both locations To remove the selected program from both your device and this computer click Remove i ce we Figure 1 Installing DL TCL NET INSTALLATION O 3 once the installation has been completed the following message appears Application Downloading Complete Please check your mobile device screen to see if additional steps are necessary ta complete this installation Figure 2 Checking your Device Screen Now all necessary files are downloaded onto the Windows CE NET device 2 3 STARTING DL TCL NET CLIENT To start DL TCL NET tap the Start button on the screen and select the DL TCL NET o
13. KYMAN NET MOBILE COMPUTER The given key seguence activates the specific function when using the following mobile computer overlays BLUE Arrow Display scrolling The following images show the keyboard overlay of the Kyman NET alphanumeric model for VT 5250 and 3270 terminal emulation VT Terminal Emulation 41 O DL TCL NET 5250 Terminal Emulation 42 TERMINAL EMULATION KEYBOARD OVERLAYS 3270 Terminal Emulation 43 lt D DL TCL NET The following images show the keyboard overlay of the Kyman NET numeric model for VT 5250 and 3270 terminal emulation VT Terminal Emulation 44 TERMINAL EMULATION KEYBOARD OVERLAYS 5250 Terminal Emulation 45 O DL TCL NET 3270 Terminal Emulation 46 TERMINAL EMULATION KEYBOARD OVERLAYS O DATALOGIC SKORPIO MOBILE COMPUTER The given key sequences activate specific functions when using the following mobile computer overlays ALT Arrow Display scrolling CTRL key Enabling the function printed in white above the selected key except for F1 F2 F3 and F4 which are directly selectable by pressing the corresponding key The following images show the keyboard overlay of the Datalogic Skorpio for VT 5250 and 3270 terminal emulation AAA i saan Mam y 28889 LII VT Terminal Emulation 47 O DL TCL NET 5250 Terminal Emulation 48 TERMINAL EMULATI
14. N FROM MOBILE COMPUTER gt Face It defines the font type to be used All Windows CE NET fixed space font styles are available The defined font will be adopted as soon as the terminal emulation is started Once the emulation session is closed the font selection is restored to the default value Available fonts are Courier New MM2000LC Crystal Monofonto Bitstream Vera Sans Mono Monofur Everson Mono Latin 6 Height It defines the height of the font to be used Bold It enables disables the bold attribute Rows X Cols It displays the emulation screen resolution accordingly with font parameters settings Background It defines the background color of the mobile computer screen The selected color is displayed in the preview dialog box Foreground It defines the foreground color of the text The selected color is displayed in the preview dialog box Cursor Shape It defines the shape of the cursor Scrolling Modes The screen may be scrolled by choosing one of the following modes Fixed The mobile computer display is always locked at column O and row 0 Quadrant mode The entire host screen 80x25 is divided in different guadrants where each of them defines the maximum number of characters columns X lines available for the defined font set In AS400 emulation if the active input field is completely inside a guadrant the display will be placed to this guadrant While the input fields that cr
15. OBILE COMPUTER E TCP Keep Alive It enables disables the TCP Keep Alive functionality This function allows the mobile computer to send a NOP no operation packet to the Host at regular intervals in order to maintain the radio connection Even if the device goes into suspend mode it automatically wakes up and sends the NOP packet after the timeout interval Timeout s It defines the time interval in seconds between the transmissions of two NOP packets active only if the TCP Keep Alive option is selected Auto Run It enables disables the mobile computer automatic connection at program startup or on closure connection failure If enabled the program enters the opening mask and after 3 seconds tries to connect automatically From the Opening Mask it is possible to enter the main setup menu by pressing the ESC key before a 3 sec timeout expires Log File It enables disables the event log to track the events All data received and sent from the Host are saved to the DLLOG TXT file positioned in root Add LF to CR If checked it adds to CR the LF character to the data format when pressing the Enter key in the keyboard Del to BS It enables disables the delete command when pressing the Backspace BS key on the mobile computer keyboard Local Echo It enables disables the mobile computer Local Echo Line Mode It enables disables the VT line mode active only if the Local Echo option is selected Terminat
16. ON KEYBOARD OVERLAYS 3270 Terminal Emulation 49
17. PUTER 0d Enable scroll bar it allows enabling disabling the horizontal and vertical scroll bars Mobile Computer Key Sequence Rhino NET M ALT S Viper NET ALT S Datalogic Skorpio ALT S Datalogic Jet FUNC DOWN Kyman NET M ALT S Kyman NET num model YELLOW DOWN Digital UNIX dlitux login Digital UNIX dlitux01 dlit it ttyp3 login Figure 9 Horizontal and Vertical Scroll Bars Emulation keypad it allows enabling disabling the special keypad which permits the user to send the emulated function keys Mobile Computer Key Seguence Rhino NET TM ALT F Viper NET ALT F Datalogic Skorpio ALT F Datalogic Jet Folder key CT Kyman NET TM ALT F Kyman NET num model Folder key CU y DL TCL NET Switch to Application Manager it allows switching to the Application Manager desktop when DL TCL NET is launched from it see DL Application Manager manual for details Mobile Computer Key Seguence Rhino NET ALT M Viper NET M ALT M Datalogic Skorpio ALT M Datalogic Jet Remapping through DL Mobile Director Local Configurator DL Application Manager Kyman NET ALT M Kyman NET num model Remapping through DL Mobile Director Local Configurator DL Application Manager Switch to Locked Web Browser it allows switching to the Locked Web Browser if both DL TCL NET and Locked We
18. appear on the display The following table lists and explains all error messages Password not Valid A wrong password has been inserted Connecting KC1 The mobile computer is trying to connect to KC HOST 1 A similar message is also displayed when trying connection to other KC Hosts Memory Full An error has occurred during memory Reset and free memory allocation It is advised to reset the mobile computer Connection to host has been The connection has been terminated by the lost remote host CONNECTION NOT AVAILABLE No host or Keep Connecting gateway is available for radio communication File INI not found At startup the program did not find the reguired configuration files 34 DL TCL NET EXTENDED COMMANDS y 9 DL TCL NET EXTENDED COMMANDS 5 1 PROPRIETARY COMMANDS The proprietary commands allow exploiting standard features performed by the Datalogic mobile computers for VT emulation only The following table lists all commands managing the barcode reading by enabling disabling the device laser reader or by selecting the barcode symbology to be read ymbology Command odabar ESC lt 0 1 gt a amp ode 11 ESC lt 0 1 gt b amp ode 128 ESC lt 0 1 gt c amp ode 39 ode 39 CIP ode 39 Full ASCII ode 93 ndustrial 2 5 nterleaved 2 5 alian pharmaceutical AN 13 AN 8 AN 128 Matrix 2 5 MSI PC A PC E nable All isable All ESC lt 0 1 gt d amp ESC lt 0 1 gt e amp ESC lt 0 1 gt q amp
19. b Browser are launched from the DL Application Manager see DL Application Manager manual for details Mobile Computer Key Sequence Rhino NET ALT L Viper NET ALT L Datalogic Skorpio ALT L Datalogic Jet Remapping through DL Mobile Director Local Configurator DL Locked Web Browser Kyman NET M ALT L Kyman NET num model Remapping through DL Mobile Director Local Configurator DL Locked Web Browser YELLOW key modality only for Datalogic Skorpio by pressing the BLUE YELLOW key sequence it is possible to alternately change the modality of use of the YELLOW key Toggle press the YELLOW key to enable disable yellow mode Modifier press the YELLOW key each time it is necessary to use yellow mode see Datalogic Skorpio manual for details DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d 9250 KEYPAD 5250 KeyPad ra ST Stelle s mn S44T4235 F10 sottosistema Ni GINTER F17 F18 F19 F20 F21 F22 F23 Video QPADEV Gas er RUP RDN an Ska rex bue RST corrente KEYS F1 F24 Ibm 5250 Function Keys SRQ System Request HELP Help FEX Field Exit FLD Field Minus DUP Duplicate FLD Field Plus RST Reset RUP Roll up List Session List RDN Roll down 1 4 Session Number CLR Clear OK Close 5250 Keypad ATN Attention dy DL TCL NET VT 100 220 KEYPAD YT KeyPad Session us 1 2 3 4 WT KeyPad Ex F2 Fa r rs ro F7 ro WN
20. ed es ed Dd ata i fil Di tat 33 MOBILE COMPUTER ERROR MESSAGES eeeeeneeeennnen 34 DL TCL NET EXTENDED COMMANDS eee nene 35 Proprietary Commands sses a Hr FR eu at HD NU 35 TERMINAL EMULATION KEYBOARD OVERLAYS 37 Viper NET TM Mobile Computer eee eee 37 Rhino NET Mobile computer eee eee n 40 Kyman NET Mobile Computer eee eee 41 Datalogic Skorpio Mobile Computer eee 47 GENERAL INFORMATION GP 1 GENERAL INFORMATION 1 1 DL TCL NET M Datalogic Terminal Emulation Client DL TCL for Windows CE NET is a software providing VT100 VT220 IBM3270 and IBM5250 Telnet terminal emulation on Datalogic RF portable mobile computers having a hardware architecture for Windows CE NET operating system Viper NET Rhino NET Datalogic Jet Kyman NET and Datalogic Skorpio If some parameters of the DL TCL NET configuration defined and downloaded through the DL Mobile Director Local Configurator see DL Mobile Director Local Configurator Help on Line for details should be modified it is possible to define their new values directly from the mobile computer DL TCL NET provides enhanced features for managing the application based on the Telnet protocol terminal emulation in particular Managing the configuration of scanner parameters Managing multiple host lists Running up to 4 sessions wi
21. ep Duration ms It defines the alarm beep duration in milliseconds Beep Frequency Hz It defines the beep frequency in hertz Port It defines the port to be used to send data from the mobile computer to the printer The RS232 port indicates the electrical port IrDA indicates the optical port while Bluetooth indicates the radio communication port 23 gt DL TCL NET 3 1 5 Display Menu It allows configuring the main display parameters for the mobile computer DL TCL NET Control Panel DL TCL NET Control Panel Advanced Device Display 1 2 pi Device Display 1 2 Display 2 2 sale Font Selection Cursor Face Em v Cursor Shape INE v Height 16 w Rows X Cols 15x21 Scrolling Mode Bid Fixed Q Color Quadrant Made 8 Background BLUE i Center Cursor Q Foreground WHITE ec O v Row fi Column fi EXAMPLE 1254567 390ab TCL Scroll DL TCL NET Control Panel Connection Emulation Advanced Device Display 1 2 Display 2 2 Scanner Font Selection Color Background BLUE Height 16 Rows X Cols 11x53 Foreground WHITE y Bold EXAMPLE 1234567890abcdefghi jk LmnopgrstuvwxyzA DL TCL NET Control Panel Emulation Advanced Device Display 1 2 Display 2 2 Scanner gt Cursor Cursor shape SS BackLight Locked O TCL Scroll v4 Quadrant Mode Lock Row fi Center Cursor 7 Lock Column n Figure 20 Display Menu 24 DL TCL NET CONFIGURATIO
22. ion Login It defines the character sent as terminator of the login field AUTO Reset Mode It enables disables the activation of the Reset button when the data transmission from Host is blocked If unchecked the Reset button has to be manually pressed if checked the program will automatically activate the Reset 19 oO DL TCL NET TM 3 1 3 Advanced Menu It allows configuring the advanced configuration features Host Login Login Prompt oi Login Answer ser Pwd Prompt Password Pwd Answer ES Command Execution md Prompt md Answer Relocation Row Stati wl X betj E DL TCL NET Control Panel OK xi Connection Emulation Advanced Device Display 1 2 Display 212 scanner 4 Host Login Command Execution Login Prompt Jogin Command Prompt Login Answer user Command Answer Pwd Prompt Password Relocation Row Pwd Answer o Start Row 4 Mo of Rows lo E Dest Row 1 Figure 16 Advanced Menu Host Login To enable disable the automatic login feature it is necessary to specify the Login and Password parameters In VT emulation for the login and the password requests the user must specify the prompt received from the host and enter the value of the login and password answers in the corresponding fields It is also required to specify the character sent as terminator of the Login field 20 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER EY Login Prompt It defines the login
23. nt can be connected to the TCL FTP Server through the IP address displayed on the device as shown in the figure below Datalogic FTP SERVER Server IP Address T2e 16 12 802 You re on Remate Wait ples er leal hie ey oe Figure 13 FTP Server 3 1 1 Connection Menu It allows configuring the connection between the application and the remote host DL TEL NET Contral Panel Connection Emulation Advanced Hast Host Name IP R t Host Port 23 Emulation vt220 v Keep Connecting KC 1 Name IP fo kc2Name IP kc3Name IP kKcaName IP Multiple Session ActiveSync RMT DL TCL NET Control Panel OK Connection Emulation Advanced Device Display 1 2 Display 2 2 Scanner e Host Keep Connecting Host Mame IP Address EC1 Name IP Address 175 15D Li KC2 Name IP Address Host Port KC3 Name IP Address 23 El KC4 Name IP Address Emulation vr220 Multiple Session w ActiveSync Remote Remote Figure 14 Connection Menu 14 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER gt Host Name lP It defines the Network name or IP address to be used by the mobile computer for the first host list Host Port It defines the Telnet TCP IP port to be used by the mobile computer to connect to the first host list Emulation It defines the type of Telnet emulation to be run on the mobile computer The following selections are available VT100
24. nuous idle time Figure 21 Backlight Dialog Box 26 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 3 1 6 Scanner It enables disables the mobile computer laser reader and allows configuring other parameters dealing with the device reading features These parameters may be also configured by means of the proprietary commands described in par 5 1 The available parameters are DL TEL NET control Panel Display 2 2 Scanner About Barcode Reader Laser Enable Ks Barcode Termination Key MONE ENTER TAB FIELD EXIT Field Scan Properties Clear Before Input OOGO Barcode Configuration DL TCL NET Control Panel Emulation Advanced Device Device Display 1 2 Display 2 y 3 2 scanner mn Rd Barcode Reader Field 5can Properties Laser Enable v Clear Before Input Barcode Termination Key MOME ENTER Barcode Configuration TAB FIELD EXIT Figure 22 Barcode Data Entry Laser Enable It enables disables the mobile computer reader 27 ES DL TCL NET Barcode Termination Key It defines the key to be pressed to include a terminator character in the output data format The following selections are available None no terminator will be added to the output data format Enter if pressed the terminator ASCII value 13 will be added to the output data format Tab if pressed the terminator ASCII value 09 will be added to the output data format Field E
25. om the mobile computer keyboard Soft Trigger if enabled the laser can be turned on off by the application software Scan Always On it enables the scanner for barcode reading independently from the application software All mobile computers equipped with a COMBO module laser RFID can switch directly from laser reader to RFID reader and vice versa through the dedicated key purposely remapped by using the DL Mobile Director Local Configurator Switch Barcode RFID In this case it is fundamental to configure the module with the type of RFID tag to be read in order to execute properly the switching operation If the laser barcode is selected by default the switching operation will use the Infineon RFID tag All other parameters of the reader module have to be configured through the TCL Panel or Control Panel 32 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d 3 1 7 About This menu shows information about DL TCL NET version Machine Name and IP Address Wersion DL TCL MET Yer Info Machine Name iper NET Ip Address 172 16 12 57 DL TCL NET Control Panel Emulation Advanced Device Display 1 2 Display 2 2 Scanner About Version DL TCL MET er Info DATALOGIC Machine Mare Rhina MET roar Ln Dun Eau Ip Address 172 15 12 82 Figure 26 About Menu 33 DD DL TCL NET 4 MOBILE COMPUTER ERROR MESSAGES During the mobile computer normal functioning some error messages may
26. oss guadrant boundaries will result in a shift to the left or right of the guadrant to include completely the field For the VT emulation where the field concept is not included in the standard the display will be placed in the same guadrant where the cursor resides 25 dy DL TCL NET Center Cursor The cursor will be maintained in the screen center Locked The display is locked at the position specified by the Row and Column parameters Row It defines the row locking the display Column It defines the column locking the display TCL Scroll If checked it enables the keyboard scrolling through the CTRL arrow key sequence while if unchecked the keyboard scrolling is disabled and the CTRL arrow key sequence turns to its normal function for example in Viper NET 48 key model CTRL C corresponds to break Backlight This button opens a further dialog box where setting the related parameters Display Properties ok Background Backlight ioh Gave battery life by EY automatically turning off the backlight when not needed Turn off backlight when meee Pas more TE 15 seconds External power and device is idle for mare than 10 minutes DISpIS ERE ii E To save battery life you can adjust when the backlight automatically shuts aff Turn aff after E minute gt of continuous idle time v Automatically turn off backlight while on external power Turn aff 10 minutes of conti
27. prompt received from the host Login Answer It defines the value of the login Pwd Prompt It defines the password prompt received from the host Pwd Answer It defines the value of the password Command Execution To enable disable the automatic execution of a command it is necessary to specify Command parameters In VT emulation for the command request the user must specify the prompt received from the host and enter the value of the command answer in the corresponding fields Cmd Prompt It defines the command prompt received from the Host Cmd Answer It defines the value of the command Relocation Row It enables disables the relocation of one or more rows The user can relocate one or more lines from the physical screen of the host application to the logical screen of the mobile computer The parameters requested to activate this feature are Start It defines the line number from 1 to 25 of the physical screen to be relocated on the logical screen of the mobile computer Nr It defines the total number of rows to be relocated Dest It defines the line number from 1 to 25 of the mobile computer logical screen where the relocated line s will be placed to 21 dy DL TCL NET 3 1 4 Device Menu This menu allows defining the main parameters of the mobile computer Keyboard Upper Case a Radio Out of Range off v Host Controlled Beeper Beep Duration ms 1000 Beep Frequency Hz Printer
28. ption from the Programs list OR double tap the DL TCL NET icon available in the Connections folder on the desktop My Control pen ob Panel interne te Expilc rer OPTION ET Remote Desktop Connection ae Windows Explorer Figure 3 Starting DL TCL NET E gt DL TCL NET 3 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER Once the DL TCL NET application and configuration files have been downloaded onto the mobile computer it is possible to change the value for most of the defined parameters directly from the device by using the DL TCL NET control panel When launching the DL TCL NET program for the first time the opening mask appears DLTCU ENTER to Connect ESC to Setup Figure 4 Opening Mask To enter the control panel press the ESC key on the mobile computer display to open the dialog box where you are asked to type your password DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d DL TGL NET Enter Password i Cancel Figure 5 Password Dialog Box Once the correct password has been inserted the default password is ls it is possible to enter the DL TCL NET control panel see par 3 1 The password can be modified after entering the main setup menu for the first time By pressing the Enter key from the opening mask you try the connection with a Host or Keep Connecting gateway If no a Host or Keep Connecting gateway is available for radio communication
29. th different hosts and different emulation protocols simultaneously Managing Out of range detection Advanced barcode filtering formatting stripping and replacing functionality Selecting several fonts different font sizes foreground and background colors Mapping the keyboard for all the mobile computers Assigning macro function to mobile computer keys Managing beeper and backlight Logging events Automatic login Relocating lines to different positions Managing different display scrolling modes Managing the printer through electrical IrDA or Bluetooth interface FTP Server embedded DL TCL NET satisfies all the connection modes required by your application providing both direct connections to the host and through DL Keep Connecting gateway software 2 DL TCL NET 2 INSTALLATION 2 1 SYSTEM REQUIREMENTS In order to run the DL TCL NET it is necessary to have at least the following e Datalogic Windows CE NET device e a network interface card NIC connected to a local network using the TCP IP protocol 2 2 INSTALLING DL TCL NET ONTO THE MOBILE COMPUTER The DL TCL NET can be installed or upgraded through a PC installation process This method is available only for Windows CE NET devices connected to a PC The installation program has to be run on the PC in order to download the necessary files onto the Windows CE NET device To install the DL TCL N
30. tion session is set the current one is automatically disabled and the mobile computer starts emulating a new application session 15 E DL TCL NET Multiple Session Mode The Multiple Session parameter is set to on The mobile computer works as in Single Session mode but in this case it can manage up to 4 different applications sessions Session 1 Session 2 Session 3 and Session 4 at the same time It is possible to switch from one applications session to another by pressing the following keys in sequence or by pressing the proper button of VT or IBM keypads ALT 1 Session 1 ALT 2 Session 2 ALT 3 Session 3 ALT 4 Session 4 ALT 0 Returns to the Host list In this case the selection of a new application session causes the closure of the current one while the other applications sessions remain active KC CONNECTION Single Session Mode The Multiple Session parameter is set to off and the mobile computer tries to connect to first Keep Connecting gateway available First it tries to connect to Keep Connecting gateway 1 and if not available to Keep Connecting gateway 2 4 In case of failure the mobile computer will display the Host List entering automatically the Direct Host connection Mode If only one host is configured the direct connection to it is made automatically Once a Keep Connecting gateway is found the mobile computer enters Mode 1 only one session is allowed and the
31. xit special key available in the AS400 emulation only for IBM5250 3270 terminal emulation Clear Before Input If checked it clears the input field before sending the barcode read or before typing data 28 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d Barcode Configuration This button automatically opens the Barcode Setup application present in the Windows Control Panel This application allows configuring all scanner and code type parameters The available barcode parameters are divided into two groups Reader Parameters and Scan Parameters File Parameter Window Help Reader Parame Scan Parameters Scanner Setup lt Parameters gt File Parameter Window Hel Reader Parameters Scan Parameters Scanner Setup lt Parameters gt Figure 23 Barcode Setup 29 dy DL TCL NET Reader Parameters The barcode reading parameters and values are dependent upon the type of laser module mounted in your mobile computer File Parameter Window Hel Text Formatting Decoding Globals Aiming Code39 Twniofpive Plassey Codabar Codel128 Codelli Code93 MSI LipcEan Scanner Setup lt Reader Parameters gt File Parameter Window Hel Port Serial BaudRate 9600 Frame Bits a Stop Bits 1 Parity Read Timeout Scanner Setup lt Reader Parameters Figure 24 Reader Parameters 30 DL TCL NET CONFIGURATION FROM MOBILE COMPUTER 0d Scan Parameters The Scan Parameters are common
Download Pdf Manuals
Related Search
Related Contents
be.ez La Robe MacBook (Pro) 13 GGM.D014 Square Table Alarm_IS_11.13.indd TL-SF1008D_V7_QIG_7106503195_Ca Kallos KJMN Intelligent Intrusion Detection System - Nitin Bhatia えて安心です~] - 前田シェルサービス MARCHÉ PHOTOCOPIEUR 2009 Copyright © All rights reserved.