Home

User Manual - ADFWeb.com

image

Contents

1. Network protocol settings a m Use Telnet REC 2217 protocol E Use raw data transmission algorithms x g i Fort read access rights ll we a Port write access rights al w 5 2 peeeeneeteritesanssseeeeneanenes ceseeeneeeneeeenenean z l L vlend keep alive every 7 sec noreplyevery 1 sec 8 Lll E mr m1 Break connection if no activity For User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 35 of 38 Industrial Electronic Devices MECHANICAL DIMENSIONS EO LEDI ON fraa R R T T S Tx Re 5 V OV El R5422 port RS232 port Power Supply D LED Serial comm Dip Switch B 5 aN AC O LEDI Device state 12 35V DE DO LEG Ethernet consi f Ethernet Serial Converter HD67648 A1 232 422 E O LEGS Etherneti Te Pham ti www ADFweb com oHS E E O LEDA Ethernet Tx Qn is o a Dip Switch A 2a Ethernet Date Code cs MAC 10 64 2 07 1C 4D Om oN 08 14 B176 Serial Nr B7021 ae ogi a 23mm 120 mm 4 72 inch 0 9 inch Housing PVC Weight 200g Approx Figure 9 Mechanical dimensions scheme for HD67648 A1 232 HD67648 A1 485 HD67648 A1 422 HD67648 A1 232 485 HD67648 A1 232 422 ADFweb com S r l AL Industrial Electronic Devices ORDERING INFORMATIONS User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 36 of 38 The ordering
2. Figure 8 PROTECTION window ADFweb com S r l iV User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 32 of 38 Industrial Electronic Devices CHANGE BAUDRATE AND PARITY ON THE FLY Enabling the option Enable change baudrate on the fly in the modality Remote COM Port is possible to change the baudrate parity and data bits of the serial port by sending a UDP frame into the selected Port The new baudrate parity and data bits are saved in RAM so when you turn off the device you loose these parameter and the device starts with the default value ve Note x You can use this modality only in the Remote COM port modality The packet to send for change these parameters are BAUD lt baud value gt PARITY lt parity value gt DATABIT lt parity value gt lt serial type gt The admited value for Baudrate are 1200 2400 4800 9600 19200 38400 57600 and 115200 The Admited value for Parity are 0 None 1 Odd 2 Even The Admited value for Data Bits are 7 7 Data Bits 8 8 Data Bits The admited value for serial type are 232 RS232 485 RS485 Example To set the Baudrate of RS485 port at 115200 Odd parity and 7 data bits you have to send in ASCII BAUD 115200 PARITY 0 DATABIT 7 485 In exadecimal 42 41 55 44 3D 31 31 35 32 30 30 3B 50 41 52 49 54 59 3D 30 3B 44 41 54 41 42 49 54 3D 37 3B 3
3. Warning A When using 7 Data Bits and Parity Node the number of Stop Bits must be 2 For all other cases the Stop Bits must be 1 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 13 of 38 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC evice consumption W VA Caution Not reverse the polarity power OV Ground V Positive wire V AC min 8V max 24V V DC min 12V max 35V HD67648 A1 232 HD67648 A1 485 HD67648 A1 422 HD67648 A1 232 485 HD67648 A1 232 422 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 14 of 38 Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode J Normal H Boot
4. 000o oam a a j h i 00o RS485 RS232 Serial Device Serial Device Serial Device Serial Device Serial Device Note This solution allows also an internet connection of the device so the PC and one or more HD67648 A1 xxx can be connected together through Internet ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 6 of 38 Industrial Electronic Devices Typical Application Tunnel Point to MultiPoint Flow data Master Slave ae www ADFweb com Ethernet 10 100 BASE T Bi maese oi meee wie ae 000o Bi a 000o RS232 Serial Slave Serial Slave Serial Slave Serial Slave Serial Master Note This solution allows also an internet connection of the device so the PC and one or more HD67648 A1 xxx can be connected together through Internet _ ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 7 of 38 Industrial Electronic Devices CONNECTION SCHEME Dip Switch A Dipi Must be at ON Dip2 Functioning Mode EH nia OLED On Tx Rx 5 V OV RS232 port Power Supply O LED Serial comm BAVAC ar O LED Device sate 12 35V DE 0 LE Ethernet comm SAADE E ees Ethernet Serial Converter D LEDS Ethernet Tz HDE7648 A1 232 C oH Etherneti E we HS OOLEDS Ethernet Tx an ne
5. 8V max 24V V DC min 12V max 35V Figure 1b Connection scheme for HD67648 A1 485 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 9 of 38 Industrial Electronic Devices Dip Switch A Dipi Must be at ON Dip2 Functioning Mode E 7 a S a R5422 port Power Supply O LED Serial camm Dip 5witch B E AC O LEDI Device etate Lda AW The O LEM Ethernet conn E ie pzd EES Ethemet Serial Converter nc HD67648 A1 422 CE Foramen www ADFweb com HS O LEDS Ethernet Te On Dip Switeh A ee E Ethernet P Date Code cs MAC 1064E2071c4c Rail DIN a S Shield to Isolated Ground T Inverting transmitter V Positive wire T Noninverting transmitter E 1 z Dip2 RS422 Termination Resistor R an ater V AC min 8V max 24V hie R Noninverting receiver P a 220 Ohm R Inverting receiver V DC min 12V max 35V Figure 1c Connection scheme for HD67648 A1 422 ADFweb com S r l Industrial Electronic Devices Dip Switch A Dipi Must be at ON Dip2 Functioning Mode Normal wl Boot O LEDI 0H O LED Serial comm Dip Switch B O LEDI Derice state O LECH Ethemet comm Ess E i O LEDS Cthemet Tx HD67648 A1 232 485 Ethemetd www ADFweb com O LEDA Ethernet Tx Q n Dip Switch A Ethernet2 s Date Code c s MAC 10 64 E2 07 1C 4C eid 08 14 B176 Seri
6. are on the Slave side Select Madality Tunnel Point to MultiPoint a Note Work with Broadcast Work with Keep Alive EAN This modality uses UDP packets Select Device HD67648 232 Al SLAVES LIST HD67648 485 Ai B MASTER Main select Device The window is divided in two anes section one for Master device and ETHERNET SLE the other for Slave devices Is Aade oa aea ETHERNET possible to assign a label to each device in order to have a name to use for understand the project M betae 792 168 1 SubNet Mask SubNet Mask 955 joss i255 ldo IP Address TimeOut Keep Alive 10000 Seconds Use Gateway The means of the fields for ETHERNET are Keep Alive Port 10002 Keep Alive Every Seconds In the field IP Address Keep Alive Port the IP address of the Converter is defined J Enable Serial J Enable Serial In the field SubNet MERN Port Mask the Subnet Mask of the Converter is defined iii slice If the field Use Gateway Baudrate 115200 Baudrate is checked in the field Parity Tore ity below it is possible to l insert the IP Address of EE 3 Remove Slave Vo Bis the gateway used for going out to the net in the field h Active Seriale Driver under Figure 6 Devices Setting window Tunnel Point to MultiPoint Work with Keep Alive ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 28 of 38 Industrial Electronic Devices In the
7. between each one or in such a way that both read the IP address of the other one The window is divided in two section one for Devicel and the other for Device2 Is possible to assign a label to each device in order to have a name to use for understand the project The means of the fields for ETHERNET are In the field IP Address the IP address of the Converter is defined In the field SubNet Mask the Subnet Mask of the Converter is defined If the field Use Gateway is checked in the field below it is possible to insert the IP Address of the gateway used for going out to the net ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 23 of 38 a i Set Communication SW6 7648 Set Communication Setting Select Madality Tunnel Point to Point Select Device HD67648 232 Al Select Device HD67648 485 Al DEVICE1 Device i DEVICE Device 2 ETHERNET ETHERNET IP Address L he IP Address SubNet Mask 2 7 3 2 5 j 5 j i SubNet Mask E Use Gateway G2 p ta i E Use Gateway J Enable Serial J Enable Serial Fort Fort SERIAL SERIAL Baudrate 115200 Baudrate 115200 Parity None Parity Even Data Bits 5 Data Bits 5 TCP E UDP Force socket TCP open Figure 4 Devices Setting window Tunnel Point to Point User Manual Ethernet Serial AL Document code MN67648_ ENG Revision 2 011 Page 24 of 38 Industrial Elec
8. connections Server D C Step 2 gt Connect serial port to remote host clienti a Share serial port using UDP 3 T Select port type you want to create i C Step 3 gt Select Serial Port COMIO ati aria oA Strict baudrate emulation ai tice ced aNer E Sry Pea Remote IP Host name 192 168 0 10 10001 F Z MOTE IF you choose 2 and P addess Port more IF s TELNET protocol will ow 192 168 0 10 10001 he unavailable S z AL Industrial Electronic Devices Go in the Connection prefs Section Step 1 Select the RAW protocol Step 2 Select the Send Keep alive option Step 3 Confirm the parameters and create the Virtual COM port ADFweb com S r l Hel T2 Edit Se H Ea rial to Ethernet Connector COMS Client Ey Delete Zx Delete all m Create mirror QD re User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 34 of 38 Serial to Ethernet Connector 5 0 by Eltima Software ianea mrada J mdy anced THE oe See _ a Ea Create connection Ep Edit connection au TOMIO Client Connection port settings Connect to remote end only when local virtual port is open 5000 MSEC 9800 Draka B T Las On error retry to establish connection every Baarate Default port settings a T Enig EF ae fni paT y T r F i Ho Flow control Mone No parity Stop bits
9. field TimeOut Keep Alive Seconds insert the time that the Master waits for receive a Keep Alive from a Slave If at least one Keep Alive message isn t arrived from a slave in this time the Master don t sends the serial data to that Slave Inthe field Keep Alive Every Seconds insert the time interval between the Keep Alive messages sent by the Slaves In the field Keep Alive Port the port used by the Master for receive the keep Alive messages from the Slaves or used by the Slaves for sends the the keep Alive message to the Master is defined If the field Use Gateway is checked in the field below it is possible to insert the IP Address of the gateway used for going out to the net The means of the fields for RS232 RS485 RS422 are The field Enable Serial is used for select if the serial is used field checked or not field unchecked For the codes with only one serial this field isn t editable is always checked for the codes with two serials at least one of the two must be checked Inthe field Port the Port used to communicate with Converter using UDP protocol is defined The port of second serial must be different from the first one Inthe field Baudrate the velocity of the serial line in use is defined Inthe field Parity the parity of the serial line in use is defined Inthe field Data Bits the number of data bits used for the serial line communication i
10. 4 3 8 35 3B ADFweb com S r l Industrial Electronic Devices ACTIVE SERIAL DRIVER User Manual Ethernet Serial Document code MN67648 ENG Revision 2 011 Page 33 of 38 Before pressing the Active Serial Driver button from the General Parameter window it is necessary to download the Serial to Ethernet Connector software from the following link www adfweb com download filefold serial ethernet connector zip After the installation of the software you have to enter in the SW67648 go into the General Parameter section and press the ACTIVE SERIAL DRIVER button At this point it is possible to configure the virtual COM port following these steps Go in the Type Section Step 1 Active the Advanced Mode Step 2 Active the Client Mode Step 3 Select the COM port to use with the device It is better if you use a COM port that does not exist in your system Step 4 Insert the IP Address and the Port of the Device and then press the ADD button Step 5 Check that the IP and the Port are correct ADFweb com S r l i Serial to Ethernet Connector 5 0 by Eltima Software x Ik a Edit lk a Delete Ex Delete all eal Create mirror D Help Lidl Advanced mode l i Step 1 Serial to Ethernet Connector Eg Create connection Ep Edit connectior all Mirror conmection ce COMS Client Select connection type you want to create i Share serial port for incoming
11. 4V Sag VDC min 12V max 35V Connector2 RS232 Isolated port GND Ground to Isolated Ground Rx Rx line x Tx line IIS Shield to Isolated Ground IIT Inverting transmitter oip RS422 Termination Resistor R T Noninverting transmitter j 230 Ohm R Noninverting receiver ey IIR Inverting receiver Figure 1e Connection scheme for HD67648 A1 232 422 Open A 220 Ohm g Open ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 12 of 38 Industrial Electronic Devices CHARACTERISTICS The devices are Ethernet Serial Converter They allows the following characteristics Triple isolation between RS232 RS485 RS422 Power Supply RS232 RS485 R422 Ethernet Power Supply Ethernet Two directional information between RS232 RS485 RS422 bus and Ethernet bus Mountable on 35mm Rail DIN Auto sensing Ethernet 10 100 Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67648 software on your PC in order to perform the following Define the parameter of Ethernet line Define the parameter of Serial line Update the device These devices can be used for doing the following configurations of connection Remote COM Port Tunnel Point to Point Ethernet bridge for a serial line Tunnel Point to Multipoint
12. Enable Serial Inthe field Port the Port used to communicate with Converter using TCP UDP protocol Port is defined The port of second serial must be different from the first one In the field Socket Disconnect TimeOut Seconds enter a time in seconds If no data pass through the socket for the seconds defined the socket disconnects socket TimeOut Seconds SERIAL Inthe field Baudrate the velocity of the serial line in use is defined Baudrate Inthe field Parity the parity of the serial line in use is defined Parity Inthe field Data Bits the number of data bits used for the serial line communication is Data Bits g defined Enable change baudrate on the fly If select the Enable Change baudrate on the fly is possible to change the baudrate parity Port 10003 and data bits of the serial from an Ethernet command see CHANGE BAUDRATE ON THE FLY ae OK x Cancel E section In the field Port the port to change baudrate and parity is defined i Figure 3 Devices Setting window Remote COM Port The Active Serial Driver button is used to activate the Serial to Ethernet Connector For more details go to page 33 ADFweb com S r l Industrial Electronic Devices OPERATING MODALITY TUNNEL POINT TO POINT A mode that allows the extension of a serial line using a Ethernet network The two devices in this mode must be configured in a coherent way
13. User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 1 of 38 Industrial Electronic Devices User Manual Revision 2 011 English Ethernet Serial Converter Order Code HD67648 A1 232 for Serial on RS232 Order Code HD67648 A1 485 for Serial on RS485 Order Code HD67648 A1 422 for Serial on RS422 Order Code HD67648 A1 232 485 for Serial on RS232 RS485 Order Code HD67648 A1 232 422 for Serial on RS232 RS422 For Website information www adfweb com Product HD67648 For Price information www adfweb com Price HD67648 A1 232 www adfweb com Price HD67648 A1 485 www adfweb com Price HD67648 A1 422 www adfweb com Price HD67648 A1 232 485 www adfweb com Price HD67648 A1 232 422 sn For others products see also the following links Benefits and Main Features RS232 RS485 Converter www adfweb com Product HD67118 Triple electrical isolation USB RS485 Converter Protocol independent suitable for supervision software www adfweb com Product HD67119 Two Ethernet ports RS485 Isolator Repeater Extender bus line www adfweb com Product HD67149 A1 Temperature range 40 C 85 C 40 F 185 F EtherNet IP Serial Converter www adfweb com Product HD67590 Do you have your customer protocol Then go to www adfweb com Product HD67003 Do you need to choose a device Do you want help User Manual www adfweb com Cmd helpme ADFweb com S r l Industrial Electro
14. a OM A Warning Dip1 of Dip Switch A must be at ON position for working even if the Ethernet cable isn t inserted ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 15 of 38 Industrial Electronic Devices LEDS The device has got six LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 ON supply voltage ON Device powered ON Device powered green OFF Device not powered OFF Device not powered Blinks quickly Boot state 2 Serial comm green Blinks when receive a Serial data Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 3 Device State green Blinks slowly 1Hz i l Blinks very slowly 0 5Hz update in progress Blinks when are received Ethernet Blinks quickly Boot state 4 Ethernet comm green g data Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 5 Etherneti Tx green Not used i l Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 6 Ethernet2 Tx green Not used i l Blinks very slowly 0 5Hz update in progress Serial comm ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 16 of 38 Industrial Electronic Devices ETHERNET The Ethernet connection must be made using Connect
15. accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate X collection systems m This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING The p
16. al Converter Opened Configuration of the Converter Begin Example Step 1 D New Configuration Open Configuration Step 2 gt Devices Setting Step 3 xX Update via UDP www ADFweb com Figure 2 Main window for SW67648 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 19 of 38 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button flea the folder which contains the entire device s configuration l Create New Configuration SW07048 Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported To clone the configurations of a Programmable Ethernet Serial Converter in order to configure another device in the same manner it is necessary to maintain the SW67648 folder and all its contents Open an Existing Configuration To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the button Open Configuration ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 20 of 38 Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language
17. al Nr B7020 S Shield to Isolated Ground Negative wire Dip2 Not used A Positive wire User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 10 of 38 f Tx Rx S amp S wW OW Ethernet Serial Converter V Positive wire VAC min 8V max 24V ae WV DC min 12V max 35V Connector2 RS232 Isolated port GND Ground to Isolated Ground Rx Rx line Tx Tx line Figure 1d Connection scheme for HD67648 A1 232 485 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 11 of 38 Industrial Electronic Devices Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode mel nnn N Normal B Boot O LEDI ON fraa R R T T 5 Tx Rx S V OW fraa R5422 port RS232 port Power Supply O LED Serial comm Dip Switch B B ANA 7 a seus alee ge aps Lz Device state O LEDS Biber net cons et aa l Ethernet Serial Converter iens Ethernet Tx wep HD67648 A1 232 422 C Ethernet comm Ethernet www ADFweb com RoHS Led5 O LEDS Ethernet Tx Qn Green 4 DipSwitch A Dae Goede ca Mc neicaacaol Rail DIN i I Ethernet1 Tx 08 14 B176 Serial Nr B7021 Clamp Connectors J Etherneti Port A gt RJ45 Plug Led6 J Green _ jEthernet2 Tx Connector4 Ethernet2 Port 4 2 gt x gt gt vyr en O 5 V Positive wire Se VAC min 8V max 2
18. al is used field checked or not field unchecked For the codes with only one serial this field isn t editable is always checked for the codes with two serials at least one of the two must be checked Inthe field Port the Port used to communicate with Converter using UDP protocol is defined The port of second serial must be different from the first one Inthe field Baudrate the velocity of the serial line in use is defined Inthe field Parity the parity of the serial line in use is defined Inthe field Data Bits the number of data bits used for the serial line communication is defined For add a new slave in the section SLAVES LIST is necessary to press the Add Slave button After that is possible to select the new slave from the list and modify the values For delete a slave present in the SLAVES LIST is necessary to select the desired slave and press the Remove Slave button _ Note A In the case of the MASTER the packets are sent in broadcast ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 27 of 38 Industrial Electronic Devices OPERATING MODALITY TUNNEL POINT TO MULTIPOINT WITH KEEP ALIVE This mode allows a serial line to set Communication be extended into sections using a LAN line where the device is on OQ the side of the one that controls 2W6 7648 the line is Master and the others
19. f eremer g a Date Code cs MAC 10 64 E2 07 1C 4C Rail DIN 5 08 14 B176 Serial Nr B7020 Clamp Ether a Connector3 A Etherneti Port a Ethernet2 Port ee645 RJ45 Plug ee iConnector2 RS232 Isolated port V Positive wire GND Ground to Isolated Ground Rx Rx line Tx Tx line V AC min 8V max 24V V DC min 12V max 35V Figure 1a Connection scheme for HD67648 A1 232 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 8 of 38 Industrial Electronic Devices Dip Switch A Dipi Must be at ON Dip2 Functioning Mode N a Norms Bii Seanad z S 3 V OV O LEDI ON j t jay kui O LED Serial comm Dip Switch B BIN AC or O LED Device state 12 35 DC O LEH Ethernet comen cit wi E a i i j TTi me i Ethernet Serial Converter O LEDS Etherneti Tx a ae Wep HD67648 A1 485 C 16 i te Ethemet Eleta is Ethernet comm O LEDS Ethernet Tx On Dip Switch A Ethernet2 Date Code cs MAC 10 64 E2 07 1C 4C 08 14 Bi76 Serial Nr B7020 Etherneti Tx _ Connector3 Etherneti Port T RJ45 Plug RJ45 Plu i ABS V OV aes Dip Switch B Connector2 Connectori Dipi RS485 Termination Resistor RS485 Isolated port Power Supply port Open Fa 220 0hm S Shield to Isolated Ground OV Ground iB Negative wire V Positive wire IA Positive wire V AC min
20. he Device Put Dip2 of Dip Switch A in OFF position Turn on the device At this point the configuration firmware on the device is correctly updated SWo6 648 Update Firmware from Ethernet UDP Update Device Options Firmware Read Firmware when finish Vl Configuration E 5w67648 Ethernet Update W Read Configuration when finish a Execute update firmware INIT Waiting Ver 1 001 FIRMWARE Waiting PROJECT Waiting Figure 7 Update device windows ADFweb com S r l User Manual Ethernet Serial AL Document code MN67648_ ENG Revision 2 011 Page 30 of 38 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly updated 4 Note When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67648 Al device Note When you receive the device for the first time you also have t
21. ilable gt HD67648 A1 232 gt HD67038 A1 485 HD67038 A1 422 HD67038 A1 232 485 HD67038 A1 232 422 ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 22 of 38 Industrial Electronic Devices OPERATING MODALITY REMOTE COM PORT It consists of a configuration in which the device is generally controlled by a PC that is g set communication connected using the TCP or UDP protocol It writes bytes that automatically are sent on the serial line and each byte read from the serial port is transmitted through the line to the AJE connected PC gt W67 648 Set Communication Setting The means of the fields for ETHERNET are Galed Madality Remote COM Port Inthe field IP Address the IP address of the Converter is defined ae gt Inthe field SubNet Mask the Subnet Mask of the Converter is defined Pei DECA HD ELSA ASA If the field Use Gateway is checked in the field below it is possible to insert the IP ETHERNET Address of the gateway used for going out to the net IP Address SubNet Mask The means of the fields for RS232 RS485 RS422 are Fl Use Gateway The field Enable Serial is used for select if the serial is used field checked or not field unchecked For the codes with only one serial this field isn t editable is always R5485 checked for the codes with two serials at least one of the two must be checked
22. n p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pairs conductor foil shield braid shield RS232 Connector2 The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232 cable not exceed 15 meters ADFweb com S r l RS232 Isolated port GND Ground to Isolated Ground Rx Rx line Tx Tx line j X x aN9 User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 18 of 38 Industrial Electronic Devices USE OF COMPOSITOR SW67648 To configure the Converter use the available software that runs with Windows called SW67648 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67648 the window below appears Fig 2 _f Note A It is necessary to have installed Net Framework 4 HE ADFwebicom Configurator SW67648 Ethernet Serie SW67 7648 Ethernet Seri
23. nic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLE OF CONNECTION CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS ETHERNET RS422 RS485 RS232 USE OF COMPOSITOR SW67648 NEW CONFIGURATION OPEN CONFIGURATION SOFTWARE OPTIONS DEVICES SETTING Op MODALITY REMOTE COM PORT Op MODALITY TUNNEL POINT TO POINT Op MODALITY TUNNEL POINT TO MULTIPOINT BROADCAST Op MODALITY TUNNEL POINT TO MULTIPOINT KEEP ALIVE UPDATE VIA UDP CHANGE BAUD AND PARITY ON THE FLY ACTIVE SERIAL DRIVER MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com S r l 9 NBWNNNNNG User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 2 of 38 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates REVISION LIST Revision Date Author Chapte
24. ns using a LAN line where the device is on the side of the one that controls the line is Master and the others are on the Slave side Note This modality uses UDP packets The window is divided in two section one for Master device and the other for Slave devices Is possible to assign a label to each device in order to have a name to use for understand the project The means of the fields for ETHERNET are In the field IP Address the IP address of the Converter is defined In the field SubNet Mask the Subnet Mask of the Converter is defined ADFweb com S r l SW6 7648 Set Communication Setting Select Madality Work with Broadcast Select Device HD67648 232 A1 MASTER Main ETHERNET IP Address SubNet Mask J Enable Serial Port SERIAL Baudrate 115200 Parity None Data Bits Tunnel Point to MultiPoint D Work with Keep Alive SLAVES LIST Select Device SLAVE Slave 1 ETHERNET IP Address SubNet Mask J Enable Serial Port SERIAL Baudrate Data Bits Remove Slave rel Active Seriale Driver HO6 648 465 AlL Figure 5 Devices Setting window Tunnel Point to MultiPoint Work with Broadcast User Manual Ethernet Serial AL Document code MN67648_ ENG Revision 2 011 Page 26 of 38 Industrial Electronic Devices The means of the fields for RS232 RS485 RS422 are The field Enable Serial is used for select if the seri
25. o update the Firmware in the HD67648 A1 device ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 31 of 38 Industrial Electronic Devices Warning If Fig 8 appears when you try to do the Update try these points before seeking assistance E 5w67648 Ethernet Update Check if the serial COM port selected is the correct one Aeon Ver 1 001 Check if the serial cable is connected between the PC and the device If you are using a USB gt RS232 converter try with a native COM port or change the converter PROJECT PROTECTION FIRMWARE PROTECTION Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista and 8 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d Pay attention that with Windows Vista Seven 8 you have to launch the Command Prompt with Administrator Rights Take attention at Firewall lock A For all codes of HD67648 A1 or you have to use the software SW67648 www adfweb com download filefold SW67648 zip
26. of the software and check the updatings for the compositor HB Software Options SW67 648 Software Options In the section Language it is possible to change the language of the software Language Connection Options Selected Language e English EBD Software Options SA Tha Page i i1 Language Connection Options V Enable Internet Connection W Check Software Update at Start of Program Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67648 check automatically if there are updatings when it is launched ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 21 of 38 Industrial Electronic Devices DEVICES SETTING By Pressing the Devices Setting button from the main window for SW67648 Fig 2 the window Devices Setting appears Fig 3 or 4 or 5 or 6 In the section Select Modality field it is possible to select the function mode of the Converter from these options Remote COM Port Tunnel Point to Point Tunnel Point to MultiPoint These operating modalities are described in the following pages In the section Select Device field it is possible to select the device used for the project These devices are ava
27. or3 and or Connector4 of with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable RS422 For terminate the RS485 line with a 220 resistor it is necessary to put ON dip 1 for T line and or put ON dip 2 for R line like in figure Connector2 Dip Switch B RS422 Isolated port Dipi RS422 Termination Resistor T IS Shield to Isolated Ground K Open 220 Ohm T Inverting transmitter kaa _ T Noninverting transmitter Dip2 RS422 Termination Resistor R R Noninverting receiver R Inverting receiver The maximum length of the cable should be 1200m 4000 feet ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 17 of 38 Industrial Electronic Devices RS485 For terminate the RS485 line with a 220Q resistor it is necessary to put ON dip 1 like in figure Connector2 Ir Dip Switch B RS485 Isolated port Dip1 RS485 Termination Resistor S Shield to Isolated Ground 220 Ohm B Negative wire A Positive wire Dip2 Not used _ SBA The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belde
28. part number is formed by a valid combination of the following HD67648 A 1 xxx yyy Second Serial Port 485 RS485 on Removable 5mm Screw Terminal connector 422 RS422 on Removable 5mm Screw Terminal connector First Serial Port 232 RS232 on Removable 5mm Screw Terminal connector 485 RS485 on Removable 5mm Screw Terminal connector 422 RS422 on Removable 5mm Screw Terminal connector Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67648 Ethernet Serial Converter Order Code HD67648 A1 232 Ethernet Serial on RS232 Converter Order Code HD67648 A1 485 Ethernet Serial on RS485 Converter Order Code HD67648 A1 485 Ethernet Serial on RS422 Converter Order Code HD67648 A1 232 485 Ethernet Serial on RS232 RS485 Converter Order Code HD67648 A1 232 422 Ethernet Serial on RS232 RS422 Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 37 of 38 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or
29. r Description 1 002 01 02 2013 Fl All Revision 2 000 18 04 2013 Fl All New order codes 2 010 21 02 2014 Fl All Software changed v2 000 2 011 13 05 2015 Fl All Revision WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 3 of 38 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and Safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if
30. roduct conforms with the essential requirements of the applicable EC directives ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 38 of 38 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
31. s defined For add a new Slave in the section SLAVES LIST is necessary to press the Add Slave button After that is possible to select the new slave from the list and modify the values For delete a slave present in the SLAVES LIST is necessary to select the desired slave and press the Remove Slave button ve Note of s In the case of the MASTER the UDP packets are sent to each slave that is present and active in the network ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 29 of 38 Industrial Electronic Devices UPDATE VIA UDP By pressing the Update via UDP button it is possible to load the created configuration into the device and also the Firmware if necessary This by using the Ethernet port If you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A in ON position SW6 648 Update Firmware from Ethernet UDP Turn on the device Connect the Ethernet cable Insert the IP Address of HD67648 Insert the IP 192 168 2 205 192 i58 2 205 Press the Ping button Device Found must appear NV n Check the Connection the device Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off t
32. they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com S r l iy User Manual Ethernet Serial Document code MN67648_ENG Revision 2 011 Page 4 of 38 Industrial Electronic Devices 5 EXAMPLES OF CONNECTION Ethernet 10 100 BASE T www ADFweb com W wi TEEI wi ae 000o wi imr KEK PC with Remote COM Port RS232 RS422 i e COM4 COM5 COMB COM9 Typical Application Remote COM Port Serial Device Serial Device Serial Device Serial Device i e on COM4 of PC i e on COMS5 of PC i e on COM8 of PC i e on COM9 of PC KA Note This solution allows also an internet connection of the device so the PC and one or more HD67648 A1 xxx can be connected together through Internet ADFweb com S r l User Manual Ethernet Serial Document code MN67648_ ENG Revision 2 011 Page 5 of 38 Industrial Electronic Devices Flow data Typical Application Flow data Tunnel Point to Point Ethernet 10 100 BASE T o www ADFweb com Hi mi ee0e Bi mi
33. tronic Devices The means of the fields for RS232 RS485 RS422 are The field Enable Serial is used for select if the serial is used field checked or not field unchecked For the codes with only one serial this field isn t editable is always checked for the codes with two serials at least one of the two must be checked Inthe field Port the Port used to communicate with Converter using TCP UDP protocol is defined The port of second serial must be different from the first one Inthe field Baudrate the velocity of the serial line in use is defined Inthe field Parity the parity of the serial line in use is defined Inthe field Data Bits the number of data bits used for the serial line communication is defined If the field TCP is checked the Protocol used is the TCP if the field UDP is checked the Protocol used is the UDP Only if the protocol is TCP is possible to select the field Force socket TCP open When is selected the Converter opens the TCP connection with the end point automatically at start up and if the end point closes the connection the Converter tries to reopen it cyclically ADFweb com S r l Industrial Electronic Devices User Manual Document code MN67648 ENG Ethernet Serial Revision 2 011 Page 25 of 38 OPERATING MODALITY TUNNEL POINT TO MULTIPOINT WITH BROADCAST This mode allows a serial line to be extended into sectio