        K3GN 1/32 DIN Digital Panel Meter
         Contents
1.       822 d   aD 9 OUTI   7      a  O PASS      lt  lt     6 1   7 ee 93 2 at  OUT  abe   b COM                            10 1 32 DIN Digital Panel Meter KS3GN    Linear Output    Linear voltage output    Linear current output       Operation    OMRON    Note  The commons for linear output and transistor output on models  with L1 and L2 are connected internally   Depending on how the common is wired for externally  connected devices  unwanted current paths for the linear  output signal in the circuit may prevent the output signal from  being output   When connecting an external device  externally connect a relay  to the transistor output or provide another means of insulation        E Main Functions    Scaling    The K3GN includes a scaling function that can convert the input  signal to a desired value and display that value     The displayed values can be freely adjusted to shift values  to create  reversed displays  or to create positive negative displays     Display Display  value value  DISPLAY2                       DISPLAY2               C5 J JOJ  oar a dare       fC 4 AC 4  oar  4 Dar     DISPLAY 1 j      Dice a a    INPUT2  nee Lae i Input  value    INPUT1 INPUT2   CaP    Za P2  Input value    Teaching    Teaching is used when using scaling or setting comparative set  values to set the present measurement values as the set values  instead of inputting with the Shift and Up Zero Keys  Teaching is  useful for making settings while checking the operation status of the  
2.       ann omron    1 32 DIN Digital Panel Meteli    Optimal Panel Meter for Downsizing Equipment and Control Panels   Models with Linear Current and Voltage Output Added to the Series             OMRON  K3GN    1 32 DIN Digital Panel Meter    e CE marking and UL CSA approval mm     scheduled to be free of hazardous  substances by March 2006    e Two color display  green red   e Multi range input                Accepts process voltage current and pulse input  and displays digital  data  all in one Unit       High visibility  7 mm high  5 digit display with programmable display  color     Selectable output  2 relay outputs  3 transistor outputs  and RS 485       Linear output  0 to 20 mA DC  4 to 20 mA DC   0 to 5 VDC  1 to 5 VDC  0 to 10 VDC       Scaling  HOLD  and forced zero functions   NEMA4X IP66 front panel      EN IEC conformity with CE marking and UL CSA approval     realrzing    Features       Lineup of Models with Linear Current Equipped with  and Voltage Output Data Transfer Output    New models with linear current voltage output have been added to the series for convenience when  handling logging of measurement signals and signal insulation     alg Outputs 1 an 2  gt  Board type computers and PLCs  DC current current signal  gt    fas    etc  3 a a     ET       pressure  distance  flowrate         4 to 20 mA DC  gt     A  ggg Outputs 1 and 2  gt  4 le e x   Rotary pulse signal omon Kacr Pe   gt A   ON OFF pulse  processor  etc   Eo a  1 to 5 VDC M oa    Display Col
3.     Models with Normally Energized Relays ot EE ont      K3GN NDC 400 24 VDC a  Lower limit Note  If Upper Lower Limit is selected  the    K3GN NDC FLK 400 24 VDC    K3GN NDC L1 400 24 VDC Measurement    upper limit and lower limit for the com    parative set value can be set individu    ally and will be displayed for OUT1 and  T2        value       K3GN NDC L2 400 24 VDC    Hysteresis       Set value    ON  Output  OFF       1 32 DIN Digital Panel Meter KS3GN    omrRon  Connections       E Terminal Arrangement    Output terminals       Models without  communications    OUT1 NC OUT2 COM    OUT1 PASS OUT2 COM    ae  LA    OUT1 PASS OUT2 COM    27 101    Models with    Models with  PNP transistor outputs INPN transistor outputs  relay outputs    communications          Models with  linear output  Models with       bt  Operation t  i KZ    power supply  24 VD    Models with    Event or pulse contact input    4    8    6     ee  Voltage  Current    Analog input    Analog input       Models with PNP inputs  Models with NPN inputs    Event or pulse contact input    Operation power Connect the operation power supply     Event input or pulse contact input Operates as follows depending on parameter         O O setting   e Holds process value   e Calibrate the process value to zero and clear  the forced zero function   e Pulse or contact input     O   Analog input Connect the voltage or current analog input         RS 485 communications terminals   Linear output 0 to 20 mA DC  4 to 20 
4.   Tem   __ Resistive Toad  e0sp      Min  permissible load 10 mV  10 uA   P level  reference value   Mechanical life 50 000 000 operations min   ata    switching frequency of 36 000  operations hr     Electrical life 100 000 operations min   at the rated   at an ambient load with a switching frequency of  temperature of 23  C  1 800 operations hr     Transistor Output  Rated load voltage    Max  load current  Leakage current 100 uA max     Communications Specifications    eS    Read write comparative set values    nications   Writing to the  read write scaling values  enable   disable the writing of data through  communications  forced zero control   and other data           Linear Output    0 to 4to  Oto5Vi1lto5V  Oto  20 mA   20 mA 10 V  Permissible load 500 Q max  5 KQ min   impedance    Resolution  Approx 10 000    Output error  0 5  full scale   0 5 full scale    0 15 V at 1 V or less  no  output for O or less           OMRON       6 1 32 DIN Digital Panel Meter KSGN    omrRon  Nomenclature       1  Main display 2  Status indicators       r7   4            2  Status indicators  SASA    _ q amy   3  Level indicator lie bell Af jal wr  ri I iter  l gy Ta  gt  pf pe  M  S o I TMW    wes re ee a oe ee YP Oe a aa mer    4  Level key    5  Mode key 6  Shift key 7  Up Zero key    1  Main display Displays process values  parameters  and set values   2  Status indicators Lit when output 1 is ON   Lit when output 2 is ON   it when a set value is being displayed or changed     Lit 
5.  commands ANNE DC current input oe  from a PLC or other external device        e Process meter  e Rotary pulse meter  e Indicator for a PLC or computer using RS485 communications    Pulse signal input    BBG       Digital data    OMRON    1 32 DIN Digital Panel Meter    K3GN       1 32 DIN Digital Panel Meter for Downsizing  Equipment and Control Panels    e Compact size  48 x 24 x 83  W x H x D      omen Gay    e Multi input compatible  DC voltage current  rotary pulse  ae   e Two display colors  switchable   green red  P   e Selectable outputs    e CE marking and UL CSA approval       Splash proof construction  NEMA4X  equivalent to IP66      AN Refer to Safety Precautions on page 14        Model Number Structure  E Model Number Legend       K3GN L_ L_J L  L  24 VDC  1 2 3 4  1  Input Type  ND  DC voltage current  NPN  PD  DC voltage current  PNP  2  Output Type  C  2 relay contact outputs  SPST NO   C FLK  2 relay contact outputs  SPST NO  and RS 485  C L1  2 relay contact outputs  SPST NO  and DC current  0 to 20 mA  4 to 20 mA   C L2  2 relay contact outputs  SPST NO  and DC voltage  0 to 5 V  1 to 5 V  0 to 10 V     T1  3 transistor outputs  NPN open collector   T1 FLK  3 transistor outputs  NPN open collector  and RS 485  T1 L1  3 transistor outputs  NPN open collector  and DC current  0 to 20 mA  4 to 20 mA   T1 L2  3 transistor outputs  NPN open collector  and DC voltage  0 to 5 V  1 to 5 V  0 to 10 V   T2  3 transistor outputs  PNP open collector   T2 FLK  3 transis
6.  sensor is processed and the pressure is  displayed  Remote monitoring of the operation is possible with the  communications function        Exhaust valve    Monitoring of Motor Load Current    lf the startup time compensation of the K3GN is enabled  the KGN  will not be influenced by the inrush current from starting the motor   and no signal will be output from the K3GN        Power supply    Electromag  l    netic relay 24 VDC power supply        Signal input    OUT1   Upper limit  alarm     OUT2  K3GN  Lower limit  alarm     K3FK  CT Converter    OMRON    Monitoring Difference between Two  Line Speeds    The difference between the two line speeds is calculated by the PLC  and the result is written via RS 485 to the KSGN where it is  displayed     RS 485 communications output   calculation result     iS        K3GN    Set the in   put type to   Remote       Monitoring the Remaining Quantity of  Soup    The distance to the surface of the soup is detected with an ultrasonic  sensor and  based on this distance  the K3GN displays the remaining  quantity  When the remaining quantity of soup decreases to less than  20   the K3GN lights the    Replenish    indicator     Ultrasonic Sensor 4to 20 mA    OUT 1       Monitoring Number of Motor  Revolutions       Power supply    Signal input       24 VDC power supply             OUT1  Upper limit     K3GN NDC        OUT2  Lower limit           OUT1  Upper limit            _   _     s UU0UUs  K3GN NDC        E2E Proximity    OUT2  Lower 
7.  volatile memory  EEPROM   possible to rewrite 100 000 times   UL508  CSA C22 2 No  142    EMC  EMI  EN 61326 Industry   Emission Enclosure  EN55011 Group 1 class A    EMS  EN 61326 Industry   Immunity ESD  EN 61000 4 2  4 kV  contact discharge   8 kV  air discharge    Immunity RF interference  EN 61000 4 3  10 V m  amplitude modulated   80 MHz to 1 GHz    Immunity Fast Transient Noise  EN 61000 4 4  2 kV  power line    Immunity Burst Noise  1 kV line to line  I O signal line    Immunity Surge  EN 61000 4 5  2 kV line to ground  power line    Immunity Conducted Disturbance EN 61000 4 6  3 V  0 15 to 80 MHz    Immunity Power Frequency Magnetic EN 61000 4 8  30 A m  50 Hz  continuous time    E Input Ranges  Measurement Range and Accuracy  Input type Pulse Remote  Ca k LL SE rat  DC DC voltage input Rotary pulse    current  Pulse 30 Hz 5 kHz  frequency  Eit SP   3     input  Connection Connection Connection  2    terminal terminal terminal       Range of display  from 49999 to  2000   99999 using        communications     Current range Frequency   mA  20 00      5000    4000    3000      2000    pe  a 0 05    Input  impedance impedance    Measurement    0 1  full scale   one digit max   at  0 1  full scale   one   0 1  full scale   one digit max   at  accuracy 23 3  C  digit max   at 23 5  C    23 5  C        Note  The shaded ranges indicate default settings        1 32 DIN Digital Panel Meter K3GN 5    E Input Output Ratings  Relay Contact Output     Incorporating G6K Relays   
8. 485  2 wire  half duplex     Linear output DC current  0 to 20 mA DC  4 to 20 mA  Load    500 Q max   Resolution  Approx  10 000   DC voltage  0 to 5 VDC  1 to 5 VDC  0 to 10 VDC   Load  5k Q min   Resolution  Approx  10 000    Display Negative LCD  backlit LCD  display  7 segment digital display  character height  7 0 mm  and single illuminated display  Scaling  prescaling  teaching  average processing  forced zero  display color selection  output type  selection  key protection  startup compensation timer  hysteresis   Ambient temperature Operating     10  C to 55  C  with no condensation or icing   Storage   25  C to 65  C  with no condensation or icing    Ambient humidity Operating  25  to 85     Note  1  A control power supply capacity greater than the rated capacity is required when the Digital Panel Meter is turned ON  Do not forget to  take this into consideration when using several Digital Panel Meters  When power is supplied  all indicators will light and outputs will be  OFF  When using startup compensation time operation  the display will read    2002    and all outputs will be OFF     2  Enabled only when using DC voltage current input   Min time for control signal input  80 ms           4 1 32 DIN Digital Panel Meter KSGN    OomRON  E Characteristics    K3GN ND K3GN PD  With DC voltage  DC current  and NPN input With DC voltage  DC current  and PNP input  DC voltage current  4 to 20 mA  1 to 5 V   5 V   10 V   No voltage contact  30 Hz max  with ON OFF pulse wid
9. G NON INFRINGEMENT   MERCHANTABILITY  OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS  ANY BUYER OR USER  ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET  THE REQUIREMENTS OF THEIR INTENDED USE  OMRON DISCLAIMS ALL OTHER WARRANTIES  EXPRESS OR  IMPLIED        LIMITATIONS OF LIABILITY    OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL  INDIRECT  OR CONSEQUENTIAL DAMAGES  LOSS OF PROFITS   OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS  WHETHER SUCH CLAIM IS BASED ON  CONTRACT  WARRANTY  NEGLIGENCE  OR STRICT LIABILITY     In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted     INNO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY  REPAIR  OR OTHER CLAIMS REGARDING THE  PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED  STORED   INSTALLED  AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION  ABUSE  MISUSE  OR INAPPROPRIATE  MODIFICATION OR REPAIR     Application Considerations    SUITABILITY FOR USE    OMRON shall not be responsible for conformity with any standards  codes  or regulations that apply to the combination of  products in the customer s application or use of the products     Take all necessary steps to determine the suitability of the product for the systems  machines  and equipment with which it will  be used     Know and observe all prohibitions of use applicable to this product     NEVER USE THE PRODUCTS FO
10. K3GN     Average Processing    Average processing can be performed for measurement values using  four levels  OFF  2 times  4 times  or 8 times   Average processing  stabilizes displayed values by averaging the corresponding input  signals that fluctuate dynamically  Select the appropriate number of  averaging times depending on the application     Forced zero Function    It is possible to shift from a  value to the zero point with Eou    one touch of the Up Zero ouri zero  Key on the front panel  for oim mi  example  when adjusting       reference values      Note  This function can be  used only when  forced zero operation  protection is released     _ EY       Changing the Display Color    The color of the value displayed can be set to either red or green   Make the setting according to the purpose and application of the  equipment in which the K3GN is installed  The display color can also  be set to change from green to red  or from red to green  according  to the status of the comparison criteria     Output Type Selection    Output operation for comparative set values can be freely selected   Upper limit  Output ON if the measurement value  gt  comparative set  value    Lower limit  Output ON if the measurement value  lt  comparative set  value    Upper lower limit  Output ON if the measurement value    comparative upper limit set value or if the measurement value is  lt   the comparative lower limit value     Key Protection    Key protection is used to restrict changes 
11. R AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT  ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS  AND THAT THE OMRON  PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR  SYSTEM     DIA E E    PERFORMANCE DATA   Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a  warranty  It may represent the result of OMRON s test conditions  and the users must correlate it to actual application  requirements  Actual performance is subject to the OMRON Warranty and Limitations of Liability    CHANGE IN SPECIFICATIONS   Product specifications and accessories may be changed at any time based on improvements and other reasons  Consult with  your OMRON representative at any time to confirm actual specifications of purchased product    DIMENSIONS AND WEIGHTS   Dimensions and weights are nominal and are not to be used for manufacturing purposes  even when tolerances are shown        ALL DIMENSIONS SHOWN ARE IN MILLIMETERS        To convert millimeters into inches  multiply by 0 03937  To convert grams into ounces  multiply by 0 03527     Cat  No  N160 E1 01___In the interest of product improvement  specifications are subject to change without notice     OMRON Corporation Regional Headquarters OMRON ASIA PACIFIC PTE  LTD   Industrial Automation Company OMRON EUROPE B V  E Avenue   Wegalaan 67 69  NL 2132 JD Hoofddorp o e  Control Dev
12. dependent on temperatures  A part life shortens when the  temperature rises  and it lengthens when the temperature falls   Parts life can be lengthened by lowering the temperature inside  the product     3  In order to prevent inductive noise  wire the lines connected to the  product separately from power lines carrying high voltages or  currents  Do not wire in parallel with or in the same cable as  power lines  Other measures for reducing noise include running  lines along separate ducts and using shield lines     4  Do not install the product near devices generating strong high   frequency waves or surges  When using a noise filter  check the  voltage and current and install it as close to the product as  possible  If several products are mounted side by side or  arranged in a vertical line  the heat dissipation will cause the  internal temperature of the product to rise  shortening the service  life  If necessary  cool the products using a fan or other cooling  method     5  Take care when cleaning the product  because the exterior of the  product may be damaged by organic solvents  thinner  benzine   etc    strong alkaline materials and strong acid materials     6  Avoid storing in high humidity or in a corrosive gas environment   including during transportation     Precautions for Safe Use    1  Use and store within the proper temperature and humidity  described in the specifications     2  Provide sufficient soace around the product for heat dissipation     3  When usi
13. ices Division H Q  The Netherlands  Analog Controller Division Tel   31 2356 81 300 Fax   31 2356 81 388 Tel   65 6835 3011 Fax   65 6835 2711  Shiokoji Horikawa  Shimogyo ku  OMRON ELECTRONICS LLC OMRON  CHINA  CO   LTD   Kyoto  600 8530 Japan 1 East Commerce Drive  Schaumburg  Room 2211  Bank of China Tower   Tel   81 75 344 7080  IL 60173 U S A  200 Yin Cheng Road  M    Fax   81 75 344 7189 Tel   1 847 843 7900 Fax   1 847 843 8568 Shanghai  200120 China    Tel   86 21 5037 2222 Fax   86 21 5037 2200  1205 1 5M  1205   D     
14. limit   Sensor       1 32 DIN Digital Panel Meter K3GN 13    Safety Precautions    OMRON          AN oF ATON    Do not touch the terminals while power is being supplied   Doing so may possibly result in electric shock     Do not allow pieces of metal  wire clippings  or fine  metallic shavings or filings to enter the product  Doing so  may occasionally result in minor or moderate injury or in  property damage due to electric shock  fire  or  malfunction caused by internal short circuiting     Do not use the product in locations where flammable or  explosive gases are present  Doing so may occasionally  result in minor or moderate explosion  causing minor or  moderate injury  or property damage     Do not use the equipment for measurements within  Measurement Categories Il  Ill  or IV  according to IEC  61010 1   Doing so may occasionally cause unexpected  operation  resulting in minor or moderate injury  or  damage to the equipment  Use the equipment for  measurements only within the Measurement Category for  which the product is designed     Failure to perform correct setting of the product according  to the application may occasionally cause unexpected  operation  resulting in minor or moderate injury  or  damage to the equipment  Ensure safety in the event of  product failure by taking safety measures  such as  installing a Separate monitoring system     Product failure may occasionally prevent operation of  comparative outputs  resulting in damage to the  connected facili
15. mA DC  0 to 5 VDC  1 to 5 VDC  0 to 10 VDC  Outputs Outputs relay or transistor outputs  There is  g also a PASS output for models with transistor  OOOO outputs        Terminal No                              1 32 DIN Digital Panel Meter K3GN 9    OMRON  E Block Diagram    Transistor output    l  See note 1      4 my   Linear output  1 O  See note 2      l 1  A D  Analog input    Input circuit conversion  terminal x circuit  Susu   l O Contact output  4 utpu X     See note 3      EEPROM Micro   computer     l    circuit    PEENTE  EEEE  ere E    Communications terminal    Communica          o   j j  See note 4    Control Waveform 7 tions driver   input C   gt  rectification     terminal circuit       E es ee ee ee eee eee eee  Constant voltage circuit 1 Constant voltage circuit 2  ONQOQOQVQQQDY ONQOQQVQQQDD    1  Transistor output models only    2  Linear output models only    3  Relay output models only    4  Models with communications functions only     E Input Circuits    Analog Input  DC Voltage Current Pulse Input Control Event Input  HOLD   Use terminal 5 for analog common  ZE RO         ee e Use terminal 2 for the common terminal         e Use the NPN open collector or the no voltage contacts for the    To A D   To A D control input   Voltage Current  input input NPN Input  COM  5  COM  5              Comparative Output   r  Contact Output      PNP Input    24 VDC            Hold Zero Pulse       Transistor Output                24 VDC    NPN Output PNP Output         
16. ng the product stored unused over a year after  purchasing  the product features may not be utilized sufficiently     4  Avoid storing outdoors or in a place that receives direct sunlight   including during transportation      5  The service life of the output relays depends on the switching  capacity and switching conditions  Consider the actual application  conditions and use the product within the rated load and electrical  service life  Using the product beyond its service life may result in  contact welding or burning     6  Be sure to confirm the name and polarity for each terminal before  wiring the terminal block and connectors  Faulty wiring may cause  destruction or burnout of internal parts    7  Use the product within the noted supply voltage and rated load    8  Do not connect anything to unused terminals    9  Output turns OFF when the mode is changed or settings are  initialized  Take this into consideration when setting up the control  system    10 Install an external switch or circuit breaker and label them clearly  so that the operator can quickly turn OFF the power        14 1 32 DIN Digital Panel Meter K3GN    11 Ensure that the rated voltage is achieved no longer than 2 s after  turning the power ON  When applying a voltage gradually  the  power supply may not reset or the output may function in an  uncertain manner     12 Mount to a panel between 1 and 5 mm thick     13 Use the specified size of crimp terminals  M3  width  5 8 mm  max   for wiring  To co
17. nnect bare wires  use AWG 28 to AWG 16  to wire the power supply terminals and AWG 22 to AWG 14 for  other terminals   Length of exposed wire  6 to 8 mm     14 Allow the product to operate without load for at least 15 minutes  after the power is turned ON     E Precautions for Correct Use    1  Note that errors may be increased by the magnification of the  scaling function    2  When using a noise filter on the power supply  check that the filter  is suitable for the supply voltage and current ratings  and then  attach the noise filter as close as possible to the K3GN     Line filter    Digital    Panel Meter            Shielded cable    Signal  inputs       Digital  Panel Meter               Connect in the direction that best  reduces noise     3  Avoid using the K3GN in places near a radio  television  or other  wireless device  These devices can cause radio disturbances  which will adversely affect the K3GN     OMRON       1 32 DIN Digital Panel Meter K3GN    15    OMRON  Warranty and Application Considerations    Please read and understand this catalog before purchasing the products  Please consult your OMRON representative if you  have any questions or comments     Warranty and Limitations of Liability    WARRANTY    OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year  or  other period if specified  from date of sale by OMRON     OMRON MAKES NO WARRANTY OR REPRESENTATION  EXPRESS OR IMPLIED  REGARDIN
18. ors Change  wo color Display   According to Judgment Outputs  Green Red    Two color Display  Green Red Selectable Output Type   There are two comparative outputs  OUT1 and OUT2  The  OUT type for each can be selected from the following three          The measurement display section changes according to the  comparative outputs  The status can be easily ascertained                             types   from a distance  yP    Upper Limit   Upper Lower Limit    Upper limit set    C t  ar Na iii l value for OUT1 2   Hysteresis  n i   Measurement i    easurement   value  Le OUT ee eee ee ee eee  SE eRe value   Lower limit set     Hysteresis    value for OUT1 2   if  N   I I  Compantve  Comparative a  outputs OFF outputs OFF    ee Note  If Upper Lower Limit is selected  the  ie eS   Lower Limit upper limit and lower limit for the    comparative set value can be set  individually and will be displayed for    OUT1 and OUT2   Measurement    value    Comparative  set value    Models Can Be Produced with Normally Comparative ON    Energized Relays  outputs OFF    K3GN   J    sd   400 24 VDC    Note  Refer to page 8 for information on models with normally energized relays     Expanded Range of Applications Multi range Input      The input type can be selected from among DC voltage  DC       Hysteresis                current  and rotary pulse signals  V DC voltage input    By using communications  the panel meter can be used as a  omron K3GN    serial communications indicator that receives
19. rature      for the K3GN does not exceed the  a specified temperature   ap   mm  pad  3 6 mm       E Wiring Precautions    e Wire the power supply with the correct polarity  Wiring with incorrect polarity may result in damage or burning   e Wire the terminals using crimp terminals    e Tighten terminal screws to a torque of approx  0 5 N m    e Wire signal lines and power lines separately to reduce the influence of noise     E Wiring Measurement Input  The following table shows the relation between input ranges and    Power Supply input terminals     e Input 24 VDC to terminals 1 and 2  Input range Input    ts    mO DC voltage DC current  ang OO   come T a  e Use M3 crimp terminals of the type shown below   10 V     F No voltage contacts and NPN open collector  2   3   5 8 i max   Models with NPN inputs   No voltage contacts and PNP open collector 4      TO   Models with PNP inputs        5 8 mm max     t       7 Be sure to read the Precautions for Correct Use and other information required when using the K3GN in the    following user   s manual   i K3GN Digital Panel Meter User   s Manual  Cat No  N102          12 1 32 DIN Digital Panel Meter K3GN    E Application Examples    Detection of Dust Exhaust    The change in the density of the dust is detected via the E3SA and  discriminated by the K3GN     Exhaust       OUT2 OUTI   Upper upper   Upper limit  limit alarm  alarm  Output  Device stops reduction  instruction    Monitoring of Tank Pressure    The output of the pressure
20. th of 16 ms min    Open collector  5 KHz max  with ON OFF pulse width of 90 us min      Displayable range 5 digits   19999 to 99999   Sampling period    Display refresh period Sampling period  sampling times multiplied by number of averaging times if average processing is selected      Comparative output response 750 ms max   transistor output   time  The time required for the judgment output to be output if the input signal rapidly changes from 15  to 95  or from 95  to 15      transistor outputs     Linear output response time 750 ms max   The time required for the analog output to be  output if the output signal rapidly changes from 15  to 95  or  from 95  to 15      Insulation resistance 20 MQ min   at 500 VDC  between external terminal and case   Insulation provided between inputs  outputs  and power supply    Dielectric strength 1 000 VAC for 1 min between external terminal and case      480 V on power supply terminals in normal mode   1 500 V in common mode   1 us  or 100 ns for square wave noise with 1 ns    Vibration resistance Vibration frequency  10 to 55 Hz  Acceleration  50 m s  for 10 min each in X  Y  and Z directions    Shock resistance Models with transistor outputs  150 m s  three times each in 3 axes  6 directions  Models with contact outputs  100 m s  three times each in 3 axes  6 directions    Approx 100 g  Main Unit ony     Degree of Front panel NEMA4X for indoor use  equivalent to IP66      protection IP20   IP00 and finger protection  VDE0106 100   Non
21. ties and equipment  Ensure safety in the  event of product failure by taking safety measures  such  as installing a separate monitoring system     Tighten the screws on the terminal block and the  connector locking screws securely using a tightening  torque within the following ranges  Loose screws may  occasionally cause fire  resulting in minor or moderate  injury  or damage to the equipment     Terminal block screws  0 43 to 0 58 N m  Do not attempt to disassemble  repair  or modify the    product  Doing so may occasionally result in minor or  moderate injury due to electric shock     OSS SO OF    E Precautions for Safe Use    Environmental Precautions    1  Do not use the product in the following locations    e Locations subject to direct radiant heat from heating equipment   e Locations where the product may come into contact with water or  oil   e Locations subject to direct sunlight    e Locations where dust or corrosive gases  in particular  sulfuric or  ammonia gas  are present    e Locations subject to extreme temperature changes  e Locations where icing or condensation may occur  e Locations subject to excessive shocks or vibration    2  Do not use the product in locations subject to temperatures or  humidity levels outside the specified ranges or in locations prone  to condensation  If the product is installed in a panel  ensure that  the temperature around the product  not the temperature around  the panel  does not go outside the specified range  Parts life is  
22. to displays and settings  using the front panel keys and to restrict menu display and  movement of operation levels  This function is effective for preventing  misuse during operation     Startup Compensation Time  Rotary  Pulse Input Only     The startup compensation time parameter keeps the measurement  operation from sending an unnecessary output corresponding to  instantaneous  fluctuating input from the moment the K3GN is turned  ON until the end of the preset period     Hysteresis    The hysteresis of comparative outputs can be set to prevent the chat   tering of relay or transistor outputs        1 32 DIN Digital Panel Meter K3GN 11    omrRoOn  Dimensions       Note  All units are in millimeters unless otherwise indicated     K3GN Panel Cutout Dimensions    Separate mounting Gang mounting  48 x No  of Panels     2 5  5         455    lt     yo Poh  Dele y i 99 29 4        40 min           The products cannot be    made waterproof when  gang mounted   Tt          omron K3GN   gt    e For installation  insert the KGN    ia ai PARRER   panel into the rectangular hole    i mmes insert the adaptor from the rear  and    push it in to reduce the gap between  the panel surface and the adaptor     Secure the Unit with the screws   For water proof installation  insert                The K3GN uses M3 terminals  A terminal the rubber gasket onto the body of  cover is provided  the K3GN   e If multiple mounted Units are used   Main Display Character Size make sure the ambient tempe
23. tor outputs  PNP open collector     Option  None  None   400  Normally energized relays    Supply Voltage  24 VDC  24 VDC    and RS 485    oO            1 32 DIN Digital Panel Meter K3GN 3    omrRon  Ordering Information    E List of Models    Supply input type  ee  DC voltage  DC current   2 relay contact outputs  eee chro  E  relays  See note   peee  DC current  0 to 20 mA  4 to 20 mA   DC voltage  DC current   2 relay contact outputs  eee Gy    Note  Refer to page 8 for information on models with normally energized relays     Specifications             E Ratings    K3GN ND K3GN PD  With DC voltage  DC current  and NPN input   With DC voltage  DC current  and PNP input    Supply voltage 24 VDC  Operating voltage range 85  to 110  of the rated supply voltage    Power consumption  at max  load   See note 1     2 5 W max   at max  DC load with all indicators lit   DC voltage  DC current  no voltage contact  open collector    DC voltage current  A D conversion Double integral method   input   Pulse signal input  Pulse measurement Periodic measurement method  method    External power supply None    Control input Present value hold or forced zero  selectable   See note 2      Outputs Relay contact output 1 A  30 VDC  resistive load   mechanical life  50 000 000 operations min   electrical life  100 000   Outputs depend on operations min     the model   Transistor output Max  load voltage  24 VDC  Max  load current  50 mA  Leakage current  100 u A max     Communications output RS 
24. when the teaching function is enabled  Flashes when the K3GN is in teaching operation   Lit when a calibration value is being displayed during user calibration  Flashes while reading a calibra   tion value     Lit while the forced zero function is activated   Lit when HOLD input is ON   Lit when communications writing is    enabled    and is out when it is    disabled        3  Level indicator Displays the current level that the K3GN is in   See below for details    4  Level Key Used to change the level   5  Mode Key Used to allow the Main display to indicate parameters sequentially     6  Shift Key Used to enable that set value to be changed  When changing a set value  this key is used to move  along the digits    7  Up Zero Key Used to change a set value  Used to set or clear a forced zero function when a measurement value is  being displayed     Level indicator          1 32 DIN Digital Panel Meter K3GN 7    OMRON    Models with Normally Energized Relays    K3GN NDC  _  400 24 VDC Relation between Output Type and Relay    e The drive operation for the output relay is reversed in these models  Output Operation  e Relay contacts can be made open  i e   OFF  when comparative set                                ae f   Upper limit Upper and lower limits  values are being judged  This is effective when constructing systems PP ie    that take failsafe measures into consideration  Set value set value   H  Measurement ERSAN  List of Models mee i Lower limit i a  ON set value a      
    