User manual SERInet ST
Contents
1. incoming network connections turn on the possibility to connect to the SERInet converter Listening network port number of port on which the SERInet waits on connection Timeout and disconnect after this many seconds of inactivity The inactive time after which the SERInet terminates the connection Setting the parameter to 0 is this function switched off Allow new connection if the existing connection has been idle for this many seconds The inactive time after which is allowed to start new connection Setting the parameter to 0 is this function switched off TCP setup for outgoing connectio n Make outgoing connections Never SERInet converter does not create connections On power up SERInet converter creates connection after connecting power supply If serial data received SERInet converter creates connection if it receives data on the serial line Connect on network port port number on which the SERInet creates connection Connect Send to this address IP address on which the SERInet creates the connection Timeout and disconnect after this many seconds of inactivity The inactive time after which the SERInet terminates connection it created Setting the parameter to 0 is this function switched off Retry failed outgoing connections The time after which the SERInet repeats the www foxtron eu f oxTRON after this many seconds attempt
2. to create connection Dividing packets Enable custom packetization logic packet dividing turn on Use UDP instead of TCP using UDP instead TCP Number of characters to accumulate before sending TCP UDP packet 128Max number of characters which will be send in one message maximum 128 data will be also send if the set time passed or the set character come Number msec to wait for accumulated characters O waits forever the time after which the received characters are sent 0 signs that the data will not be sent dependently on the time Flush TCP UDP frame when this character is received Enter NA to disable Decimal character value ASCII after which reception will be sent If the NA is input no character is selected For example CR carriage return is 13 By pressing the button Submit New Settings the selected settings are saved Serial line basic setup is shown in the following picture Foxtron SERInet Setup a 192 168 1 241 serial_conf htm F SERInet Data Port Settings Data Baud Rate Custom Baud Rate Data Bits Data Parity Stop Bits EOXTRON Network Serial Password RS 485 Half Duplex ei 19200 Submit New Settings 8 www foxtron eu foxTRON RS 485 Half Duplex half duplex two wires RS485 RS 485 Full Duplex full duplex four wires RS485 Communication speed choice Selection is possible from Data
3. Baud Rate commonly used speeds Choice Custom sets the speed defined by user Data Port Settings Communication speed chosen by user Used in the case that in Custom Baud Rate Data Baud Rate is set Custom Data Bits number of data bits None no parity used Data Parity Odd used odd parity Even used even parity Stop Bits number of stop bits Password setup is shown in the following picture Password into the web configuration is not required by default Foxtron SERInet Setup 192 168 1 241 pass htm 2 FORTRON SERInet Network Serial Password User Name Password Leave blank for no password Repeat Password Submit New Settings For change of password fill the User Name and twice new password In the case that you do not want to use password leave the password fields blank By pressing the button Submit New Settings you save new password 9 www foxtron eu FORTRON Power Express PEX In the case of using with Power Express system PEX it is suitable to insert the reduction on the RJ15 connector which is by default used for PEX bus Recommended setup CUSTOM PACKETIZATION for PEX bus Enable custom packetization logic Iv Use UDP instead of TCP Li Number of characters to accumulate before sending 128 TCP UDP packet 128Max Number msec to wait for accumulated characters 0 wait
4. ERInet unit has a six pin screw connector on the serial line side which is shown in the following picture Without the inserted reduction the serial line is routed to the screw terminals IN 9 32VDC COI EXT Q V Q GND S RxD D TxD ete 8 D TxD 9 32V Q RxD CLIT JEXT M 2 5 R JOUBAUOD J9U9U73 BES UOULHO Alternatively for use in the PowerExpress system can be inserted into the terminals EXT reduction for PEXbus connectors RJ15 which is shown in the following picture IN 9 32VDC 8 PEXbus RJ15 CER gt o x D o PEXbus RJ15 ETH passive PoE 9 32V n D o m m gt o 3 gt o o Q fe J lt A o S designation description ETH Ethernet passive PoE power supply V power supply of the bus RS485 9 32V GND ground for power supply of the bus RS485 RS485 Half Duplex RS485 Full Duplex RxD receive D D TxD D broadcast D D TxD D broadcast D RxD receive D PEXbus connector PowerExpress bus type RJ15 IN 9 32VDC external DC 9 32V alternative to PoE wires preparation 6mm 4 www foxtron eu oxTRON This unit has two power supply options passive PoE or external supply on the terminals IN 9 32VDC Consumption in both cases is 1 5W supply current is in both cases dependent on the connected voltage Power supply is distributed together with the Eth
5. FORTRON User manual version 1 1 SERInet ST converter RS485 Ethernet power supply passive PoE or 9 32V communication indication on the serial line galvanic separation RS485 ETH installation on the DIN rail 2 modules Screw terminals RS485 1 www foxtron eu FORTRON SERInet is a converter from RS485 to Ethernet TCP IP Converter is possible to be supplied passive PoE thanks to the Ethernet data cable or by power supply on the terminals Technical specification bus RS485 Ethernet speed ETH 10 100M protocol ETH TCP IP supply voltage 9 32 V I 15 VV consumption 50 150 supply 32 9V mA consumption RS485 5 mA wires cross section 0 08 1 5 mm ingress protection degree IP20 galvanic separation RS485 ETH 5 kV ambient working temperature 25 60 C storage temperature 25 60 C weight 80 g 2 www foxtron eu FORTRON ETH Connection to the Ethernet network Ethernet speed 100M it is off 10Mbit it is on 100Mbit Sending of the data on RS485 x o A MA _ blinking signalizes outgoing data on the serial line incoming communication on RS485 bus blinking signalizes incoming data to the serial line UES gt o x i 2 o 5 passive PoE 9 32V n 3 D m m o Ll ej o 2 Q fe 3 lt fo oa o o 3 www foxtron eu oxTRON Terminals connection Basically the S
6. ernet to the ETH connector Power supply is inserted in the data cable using the common passive PoE injector Supply voltage can be in range 9 32V IN 9 32VDC DC power supply 9 32V to the terminal IN 9 32VDC Passive PoE Serial line is galvanically separated from Ethernet network and has its power supply on the terminals V and GND Supply voltage can be in range 9 32V Data are sent to the Ethernet network through the TCP IP protocol Setup Setup of the SERInet converter is done by web browser To the address line input the IP address of the converter In the factory settings the address is 192 168 1 241 If the address is unknown the converter can be found using DALIconfig program which is downloadable for free on the www foxtron eu 5 www foxtron eu foxTRON Default Ethernet settings in show in the following picture Foxtron SERInet Setup dl 192 168 1 241 index htm 2 OHKTRON SERInet Network Serial Password Device Name for DHCP SERInet Addressing Mode Static z IP SETTINGS Static Settings Current Values Device IP Address fis21681 241 192 168 1 241 Device Subnet Mask 255 255 255 0 255 255 255 0 Device Gateway fis21681254 192 168 1 254 DNS Server fa2 168 1 2354 192 168 1 254 A Physical power cycle required Ethernet Link Normal z after change INCOMING TCP SETTINGS Listen for incomming network connections Iv Listening network port 23 Timeout and di
7. s forever fo Flush TCP UDP frame when this character is received B Enter NA to disable 10 www foxtron eu foxTRON Dimensions in mm sas 10 58 35 PEREAT TTT oxTRON tel 420 274 772 527 e mail info foxtron cz web www foxtron eu 11 www foxtron eu
8. sconnect after this many seconds of fo 30 20 inactivity Allow new connection ifthe existing connection has been idle for this many seconds OUTGOING TCP SETTINGS Make outgoing connections Never z Connect on network port hi 000 Connect Send to this address Timeout and disconnect after this many seconds of inactivity Retry failed outgoing connections after this many seconds CUSTOM PACKETIZATION Enable custom packetization logic Use UDP instead of TCP Learn UDP reply Address Number of characters to accumulate before sending TCPIUDP packet 128Max Number msec to wait for accumulated characters O waits forever Flush TCP UDP frame when this character is received Enter NA to disable 100 ty NA Submit New Settings Reset To Factory Defaults 6 www foxtron eu FORTRON General TCP settings Device Name for DHCP SERInet name for DHCP server Addressing Mode Static manual setup of the IP address DHCP automatic setup of the IP address using DHCP Device IP Address IP address of DALInet converter for Addressing Mode Static Device Subnet Mask network mask Device Gateway Default gateway DNS Server Domain server address Ethernet Link Normal automatic speed choice 100BT Half duplex Ethernet speed 100Mbps 10BT Half duplex Ethernet speed 10Mbps TCP setup for incoming connection Listen for