1. of a qualified medical physicist Measurement of high activity radioactive sources is potentially hazardous and should be performed by qualified personnel gt CAUTION As desired by IAEA English is the default language for labeling and manuals If translated versions are available resolve any differences in favor of the English versions WARNING Proper use of this device depends on careful reading of all instructions and labels gt gt WARNING Where applicable Standard Imaging products are designed to be used with the versions of common radiation delivery devices treatment planning systems and other products or systems used in the delivery of ionizing radiation available at the time the Standard Imaging product is released Standard Imaging does not assume responsibility liability and or warrant against problems with the use reliability safety or effectiveness that arise due to the evolution updates or changes to these products or systems in the future It is the responsibility of the customer or user to determine if the Standard Imaging product can be properly used with these products or systems Should repair or replacement of this product become necessary after the warranty period the customer should seek advice from Standard Imaging Inc prior to such repair or replacement If this product is in need of repair it should not be used until all repairs have been made and the product is functioning properly and
2. ready for use After repair the product may need to be calibrated The owner of this product has sole responsibility for any malfunction resulting from abuse improper use or maintenance or repair by anyone other than Standard Imaging Inc The information in this manual is subject to change without notice No part of this manual may be copied or reproduced in any form or by any means without prior written consent of Standard Imaging Inc 11 Warranty _ _ _ _ K lt _ _ _ _ Standard Imaging Inc sells this product under the warranty herein set forth The warranty is extended only to the buyer purchasing the product directly from Standard Imaging Inc or as a new product from an authorized dealer or distributor of Standard Imaging Inc For a period provided in the table below from the date of original delivery to the purchaser or a distributor this Standard Imaging Inc product provided in the table is warranted against functional defects in design materials and workmanship provided it is properly operated under conditions of normal use and that repairs and replacements are made in accordance herewith The foregoing warranty shal not apply to normal wear and tear or if the product has been altered disassembled or repaired other than by Standard Imaging Inc or if the product has been subject o abuse misuse negligence or accident Product Warranty Period St
3. 2 EXRADIN DIH DIODE EXRADIN DIV DIODE 2 STANDARDIMAGING lt User Manual 2 www STANDARDIMAGING 29 2 EXRADIN DIH DIODE EXRADIN DIV DIODE STANDARD IMAGING INC TEL 800 261 4446 3120 Deming Way TEL 608 831 0025 Middleton WI 53562 1461 FAX 608 831 2202 Sep 2012 2012 Standard Imaging Inc DOC 80655 00 General Precautions Warnings and Cautions alert users to dangerous condi tions that can occur if instructions in the manual are not obeyed Warnings are conditions that can cause injury to the operator while Cautions can cause dam age to the equipment WARNING Proper use of this device depends on careful reading of all instructions and labels WARNING This diode is intended for quality assurance measurements It is not intended to be connected to a patient for real time dosimetry measurements CAUTION Do not apply bias voltage to the diode at any time Presence of voltage will damage the detector CAUTION Do not drop mishandle or disassemble unit since it may result in a change of signal output or damage to diode Refer all servicing to qualified individuals CAUTION Do not sharply bend triaxial cable Damage to the cable may result in high leakage currents CAUTION Connector end of diode detector should not be submerged in water NOTE Standard Imaging does not assume any liability or guarantees when the detector is used with any electrometer or accessori
4. 50 2 1 000 0 950 0 900 0 850 0 800 j 0 2 4 6 8 10 12 14 16 18 20 Side length of square field cm Percent Depth Dose in Water Comparison 6 MV Photons Varian Clinac 21 EX 120 100 Response 96 gt a N 0 5 10 15 20 25 Depth Features and Specifications sms Diode Type P type Si diode Materials C552 shell for EMI shielding and durability potted with near water equivalent epoxy to eliminate air gaps Outside Diameter D1V REF 92740 6 88 mm 0 271 x 46 2 mm 1 817 long D1H REF 92741 6 88 mm 0 271 x 6 88 mm 0 271 x 34 8 mm 1 37 Diameter of Sensitive Area 1 mm x 0 05 mm thick Effective Depth Below Surface 0 8 mm Indicator marks or lines clearly identify internal diode orientation and active face Intended Energy Range Photons Co to 25 MV Low Noise Triaxial Cable 50 ohms 29 pF ft 1 5 m long Connector availability Standard BNC triax with HV bias capability disabled Other connector options such as TNC or type M may be available upon request Waterproof Yes may be used in water phantoms designed to mount cleanly and easily to available chamber holders Operating Voltage 0 VDC bias protected from accidental high voltage application Signal Polarity Positive Radiation response typ 5 nC Gy Leakage current typ lt 100 fA typical depends on electrometer used Temperature dependence typ lt 0 4
5. As is standard practice for other diodes it is recommended that the Exradin D1H and D1V Diodes be compared regularly to a known calibrated standard under controlled radiation conditions for accurate relative comparison Prior to shipment each diode is verified for radiation performance by comparison to a Standard Imaging Exradin lon Chamber General Operation 1 With nothing connected to the input jack of the electrometer turn the power on and wait at least 15 minutes for warm up 2 Verify the leakage of the electrometer is within the manufacturer s stated acceptable limits 3 Setup the D1H or D1V Diode for measurement in a stand plastic phantom or water phantom When positioning ensure that the active area faces the beam D1H The three vertical lines on the sides of the D12H diode provide references to indicate the center of the active area D1V The laser alignment line around the circumference of the D1V diode indicates the position of the active area NOTE While the D1H and D1V are inherently waterproof without the assistance of sleeves caps or other devices the connector end of the diode should never be submerged in water General Operation Continued av r _ 4 Connect the diode to the electrometer using an extension cable if necessary being certain there is no bias voltage selected on the electrometer 5 Allow the electrometer and diode system at least 10 minutes to stabilize making certai
6. C Sensitivity decrease at 6 MV 1 0 per kGy Dose to pulse dependency gt 99 5 over relevant clinical range Dose linearity gt 99 9 Features and Specifications Cont d Tl Field size dependency gt 97 0 Intended Field size for use up to 20 x 20 cm Directional Dependence lt 0 5 tilting 20 Operating Parameters Temperature 15 to 35 C Relative Humidity 20 to 80 non condensing Pressure 650 to 770 mmHg Storage Parameters Temperature 15 to 50 C Relative Humidity 10 to 95 non condensing Pressure 600 to 800 mmHg Product Standards Compliance IEC 60601 1 IEC 60731 WEEE RoHS 0413 Authorized representative for the EU is AMA Ltd St Felix House Flitcham King s Lynn Norfolk United Kingdom PE31 6BU Competent Authority for the EU is the Medical Products Agency Sweden Notified Body for the EU is Semko Sweden Designed to Meet Notes Service Policy ZZ If service including recalibration is required please contact Standard Imaging s Customer Service department by phone or email prior to shipping the product Standard Imaging s Customer Service and Technical Service staff will attempt to address the product issue via phone or email If unable to address the issue a return material authorization RMA number will be issued With the RMA number the product can be retu
7. andard Imaging lonization Chambers 2 years Standard Imaging Well Chambers 2years Standard Imaging Electrometers 5 years Standard Imaging BeamChecker Products 2 years Standard Imaging Software Products 1year All Other Standard Imaging Products y Standard Imaging Custom Products 1year Standard Imaging Remanufactured Products 180 days Standard Imaging Custom Select Products 80 days Consumables 90 days Serviced Product 90 days Resale Products As defined by the Original Equipment Manufacturer ADCL Product Calibration 0 90 days 100 of ADCL Calibration Costs Standard Imaging uses the 91 182 days 75 of ADCL Calibration Costs UW ADCL for recalibrations 183 365 days 50 of ADCL Calibration Costs required under warranty unless 366 639 days 25 of ADCL Calibration Costs otherwise requested days from date of shipment to customer Standard Imaging s sole and exclusive obligation and the purchaser s sole and exclusive remedy under the above warranties are at Standard Imaging s option imited to repairing replacing free of charge or revising labeling and manual conten on a product 1 which contains a defect covered by the above warranties 2 which are reported to Standard Imaging Inc not later than seven 7 days after he expiration date of the warranty period in the table 3 which are returned to Standard Imaging Inc promptly after discovery of the defect and 4 which are found to b
8. d on all returned merchandise All materials returned must be shipped pre paid Credit for returned goods will be issued to customer s account for use against future purchases of merchandise only Special orders custom products re sale not manufactured by Standard Imaging products and ADCL calibrations will not be accepted for return credit or exchange Serialization Information Standard Imaging products that are serial ized contain coded logic in the serial number which indicates the product day and year of manufacture and a sequential unit number for identification AYY DDD X A Unique product ID YY Last two digits of the year e g 1999 99 2000 00 DDD Day of the year 1 lt DDD lt 365 x Unique unit ID Number 1 lt X lt 9 10 Customer Responsibility ZZ This product and its components will perform properly and reliably only when operated and maintained in accordance with the instructions contained in this manual and accompanying labels A defective device should not be used Parts which may be broken or missing or are clearly worn distorted or contaminated should be replaced immediately with genuine replacement parts manufactured by or made available from Standard Imaging Inc CAUTION Federal law in the U S A and Canadian law restrict the sale distribution or use of this product to by or on the order of a licensed medical practitioner The use of this product should be restricted to the supervision
9. e defective upon examination by Standard Imaging Inc Transportation related charges including but not limited to shipping customs tariffs taxes and brokerage fees to Standard Imaging are the buyer s responsibility This warranty extends to every part of the product excluding consumables fuses batteries or glass breakage or material reactions Standard Imaging Inc shall not be otherwise liable for any damages including but not limited to incidental damages consequential damages or special damages Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days This warranty is in lieu of all other warranties express or implied whether statutory or otherwise including any implied warranty of fitness for a particular purpose In no event shall Standard Imaging Inc be liable for any incidental or consequential damages resulting from the use misuse or abuse of the product or caused by any defect failure malfunction or material reactions of the product whether a claim of such damages is based upon the warranty contract negligence or otherwise This warranty represents the current standard warranty of Standard Imaging Inc Please refer to the labeling or instruction manual of your Standard Imaging Inc product or the Standard Imaging Inc web page for any warranty conditions unique to the product
10. es other than those manufactured by Standard Imaging or expressly specified to be suitable for use with this specific type of detector To maintain full warranty and product liability rights always use Standard Imaging detectors together with Standard Imaging electrometers Table of Contents i General Precautions 1 Overview 2 General Operation 4 Maintenance 5 Parts and Accessories 7 Features and Specifications 10 Service Policy 10 Return Policy 11 Customer Responsibility 12 Warranty Wa STANDARDIMAGING 3 3120 DEMING WAY MIDDLETON WI 53562 1461 USA WWW STANDARDIMAGING COM Overview The Exradin D1H and D1V Diodes are P type silicon diodes attached to a 1 5 m length of low noise flexible triaxial cable that is terminated by a BNC type triaxial connector The horizontal design of the D1H allows it to be used in an orientation similar to that of a small volume ion chamber The flat top and bottom surfaces make the D1H ideal for use with solid water slabs or other phantoms The internal diode itself has a circular active area of 1 0 mm Top Overview Continued A The D1V Diode uses the same detector as the D1H but provides a vertical orientation preferred for water phantom scanning applications The D1V is also intended for use with the LUCY 3D QA Phantom When positioned with the circular top facing the radiation source the circular active area of 1 0 mm2 faces the beam Top
11. n that all cabling is lying flat and unkinked 6 Verify the leakages of diode and extension cable if used are within the manufacturer s stated acceptable limits If measured in the presence of background sources note that this signal will add to the leakage of the diode 7 Some electrometers such as the Standard Imaging MAX 4000 and SuperMAX electrometers allow the user to zero the device at any time If desired perform this system zeroing now 8 Check the system leakage Take a reading without exposing the diode to radiation This reading should be less than 0 1 of the final signal expected If it is not the leakage should be subtracted from the signal 9 Irradiate the diode and take at least 3 measurements Generally the measurements should not be moving in only one direction i e three readings that continue to drop and hence may not yet be stabilized If a current measurement is done allow sufficient time for value to stabilize 10 Analyze the data taking into account the average of the readings system leakage electrometer calibration and any other appropriate corrections to be made 11 When all measurements are completed turn off the electrometer and disconnect the diode Maintenance Ss There are no user serviceable parts within the Exradin D1H or D1V Diodes Under no circumstance should the user attempt to repair or disassemble the diode and or connector as the warranty will become void Under no
12. or Use the connector cap when not in use if applicable Maintenance Continued eee Do not Use sharp objects to attempt to clean a dirty connector Use a compressed gas other than air Use a compressed gas source that may have moisture or oil in the source or lines Use your mouth to blow on the connector e Disassemble the connector Touch the internal parts of the connector with your finger If this procedure does not resolve the drift or leakage issues contact the Customer Service Administrator to coordinate the return the product to Standard Imaging for further service If there are any questions or comments regarding this information please contact Standard Imaging or your authorized dealer Parts and Accessories VW REF 92740 92741 80441 72193 90015 90018 Description Exradin D1V Diode Detector 1mm vertical version Exradin D1H Diode Detector 1mm horizontal version Exradin Diode Detector User Manual In Air Comparison Jig MAX 4000 Electrometer SuperMAX Electrometer Performance Graphs el Angular Dependence Comparison Lucy 3D QA Phantom 10x10 cm field Co Response 96 1 050 1 000 D1V Diode PTW 60012 Exradin A1SL lon Chamber 0 900 0 5 10 15 20 25 30 35 40 45 Gantry Rotation degrees Field Size Dependence Comparison Detector depth 10 cm Co 1 300 1 250 1 200 1 150 E 5 1 100 a 1 0
13. rmal use the diode should provide years of trouble free service If assistance is desired in the proper disposal or X recycling of this product including accessories and components after its useful life please return to Standard Imaging Cleaning Triax Connectors on lon Chambers and Extension Cables Over the years Standard Imaging has had product reports of drift or leakage involving its detectors During the investigation and or servicing of these products it became apparent a significant portion of these reports were caused by dirty triax connectors The cause is typically dust that has collected on the inside connector To minimize these reports and unnecessary service Standard Imaging is providing a triax connector cleaning procedure This triax connector cleaning procedure should be periodically completed or whenever there are concerns of drift or leakage Heavier product use may require more frequent cleanings Prior to cleaning a triax connector ensure The detector is disconnected from the electrometer There is no water or moisture visible in the triax connector To clean a dirty triax connector Remove the connector cap if applicable Use only a dry and oil free compressed air source such as Chemtronics Ultra Jet Gently blow dirt and contaminants from the inside of the connector moving the air source in a circular manner a few inches from the connector After cleaning a dirty triax connect
14. rned to Standard Imaging It is the responsibility of the customer to properly package insure and ship the product with the RMA number clearly identified on the outside of the package The customer must immediately file a claim with their carrier for any shipping damage or lost shipments Return shipping and insurance is to be pre paid or billed to the customer and the customer may request a specific shipper Items found to be out of warranty are subject to a minimum service fee of 1 hour labor excluding recalibrations for diagnostic efforts and require a purchase order PO before service is performed With concurrence from customer the product may be replaced if it is unserviceable or if the required service is cost prohibitive Products incurring service charges may be held for payment Standard Imaging does not provide loaner products See the Standard Imaging Warranty and Customer Responsibility for additional information Return Policy o No merchandise will be accepted for credit without prior approval of return Please contact Standard Imaging s Customer Service Department to receive a return authorization number before returning any merchandise for exchange or credit Products manufactured by Standard Imaging must be returned within thirty days of receipt of order in like new condition No credit will be given for products returned after thirty days from receipt of order A minimum twenty percent restocking fee will be charge

Download Pdf Manuals

image

Related Search

Related Contents

Document  Sony SLV-SE600B User's Manual  Samsung 305T 用户手册  Moxa IA260-T-CE  PDF形式:144KB    GE 106716 User's Manual  GE-A380021AG    Bryant Puron Refrigerant Single Speed User's Manual  

Copyright © All rights reserved.
Failed to retrieve file