1. Hardware ONLY Pin Function Note 1 5VDC Power for Status External Indicators 2 Switch 7 Shift Mode Select Active Low 5 Pull Up 3 Led 1 drive Record Status Indicator Active Low Open Collector Output 4 Led 2 drive Play Status Indicator di di 5 Led 3 drive Stop Status Indicator ii 6 Led 4 drive Rewind Status Indicator ss di 7 Led 5 drive Fast Forward Status Indicator ge 2 8 Led 6 drive Jog Mode Indicator T A 9 Command Common 10 Switch 1 Record Command Active Low 5 Pull Up 11 Switch 2 Play Command Active Low 5 Pull Up 12 Switch 3 Stop Command Active Low 5 Pull Up 13 Switch 4 Rewind Command Active Low 5 Pull Up 14 Switch 5 Fast Forward Command Active Low 5 Pull Up 15 Switch 6 Jog Mode Select Active Low 5 Pull Up 8 ST100 VTR Controller GPI CONNECTOR Version 7 x Software 26 Pin D Type Female DB26F Version 7 x software Rev 5 x Hardware ONLY Pin 1 GPI 1 Out Record tally Pn 14 GPI 5 In Fast Forward Command 2 GPI 2 Out Play tally 15 GPI 6 In Standby ON Command 3 GPI 3 Out Stop tally 16 GPI 7 In Pause Command 4 GPI 4 Out Rewind tally 17 GPI 8 In None 5 GPI 5 Out Fast Forward Command 18 Common Ground 6 GPI 6 Out Standby 19 5 VDC 7 GPI 7 Pause 20 5 VDC 8 GPI 8 Out None 21 No Connection 9 Common Ground 22 No Connection 10 GPI 1 In Record command 23 No Connection 11 GPI 2 In Play command 24 No Connection 12 GPI 3 In Stop Command 25 No Connec
2. female connector on the POWER SUPPLY into the male 9 pin connector on the rear of the ST100 Plug the AC connector into a wall outlet 90 VAC 265 VAC 50 60 Hz Select REMOTE operation on the VTR s front panel d Set the RECORD SELECTOR SWITCHES located on the rear panel of the ST100 to the desired record mode per the RECORD SELECTOR CHART Installation is completed NOTE For AMPEX 1 and D2 VTRs set VTR ID to 0001 Connection Diagram 5 VDC 1 AMP 90 VAC 265 VAC Adapter Included Parallel Machine Control System Master Control Switcher Control Panel POWER Keypad VTR SUPPLY THRU VIR Loop THRU Pet 100 CONTRAST RS422 9 Pin Remote 5 Connector Switch Input Dry SPST contact closure momentary Status Output Open collector 50 ma sink OPTIONAL KEYPAD PROVIDED BY USER NOTE Rack mount version shown with Optional User Supplied external GPI switch inputs and tally outputs Tabletop version uses the same connections 4 ST100 VTR Controller OPERATION Select the desired transport function by pressing the appropriate switch on the front of the ST100 The Real Time Status Indicators will light to indicate the VTRs current tape transport mode For example Pressing PLAY will put the VTR into the PLAY mode The PLAY Status Indicator will light when the VTR is in PLAY mode Loss of serial communication with the VTR is indicated by ALL
3. 12843 Foothill Blvd Suite Sylmar CA 91342 818 898 3380 voice 818 898 3360 fax z NENNEN AEE EE EEE Eee eee 010 P EECH Sa www dnfcontrols com Model No ST100 VTR CONTROLLER For Version 6 x and 7 x Units USER MANUAL Rev 3 12 Table of Contents 1 REVISION HISTORY GETTING STARTED DESCRIPTION a FEATURES b TIME CODE DISPLAY c STANDARD FUNCTIONS d REAL TIME STATUS INDICATORS ACTIVE ON INSTALLATION OPERATION a RECORD MODE b RECORD SELECTOR SWITCHES c TIME CODE DISPLAY ST100 SXD FUNCTIONS REFERENCE SPECIFICATIONS FRONT PANEL REAR PANEL CONNECTORS RS422 SERIAL CONNECTOR GPI CONNECTOR Version 6 x Software GPI CONNECTOR Version 7 x Software POWER SUPPLY CONNECTOR TABLE TOP REAR AND TOP VIEW DNF CONTROLS LIMITED WARRANTY ST100 VTR Controller Nan nn amp GO W 55 GA 9 REVISION HISTORY 061703 Rev 3 0 Company header information revised 010504 Rev 3 1 Added DNF Controls Limited Warranty 102506 Rev 3 11 Added time type select function 012610 Rev 3 12 Added XDCAM functions ST100 SXD ST100 VTR Controller Getting Started DESCRIPTION The ST100 UNIVERSAL Controller provides low cost control over a wide range of RS422 VTR and DDR formats and brands in your facility 2 Simple and easy to use No complicated menus to search
4. IFT REWIND to go to the beginning of the previous clip d GO TO NEXT CLIP Press SHIFT FFWD to go to the beginning of the next clip ST100 VTR Controller Reference SPECIFICATIONS FRONT PANEL 6 Status LEDs Record Play Stop Rewind FFwd Jog 1 Power LED 3 Direction LEDs Indicates direction of Jog Shuttle Switches Record Play Stop Rewind Fast Forward Jog Shift Reset DIP Switches RECORD MODE Lockout Crash Insert Assemble Display 2 Line LCD back lit with adjustable contrast Jog Shuttle Wheel Size 19 x 5 x 1 3 4 Rack mount 7 x 5 x 1 1 2 Tabletop Weight 2 165 REAR PANEL CONNECTORS RS422 Serial Out 9 pin D type connector female DB9 F Power 5 volt D C 500 ma 90 265 VAC 50 60 Hz converter supplied Rack mount or tabletop GPI 15 pin D type connector female DB15F Status Output Switch Input SPST contact closure momentary Open collector sink 50mA ST100 VTR Controller RS422 SERIAL CONNECTOR 9 Pin D Type Female DB9 F Pin 1 Frame Ground 6 Receive Common 2 Receive A 7 Receive B 3 Transmit B gt 8 Transmit A gt 4 Transmit Common 9 Frame Ground 5 Spare SHUTTLE WHEEL SPEEDS Note represents Shuttle speeds in reverse direction ye STILL E 10 X Play Max Speed Jog Wheel 50 X Play 50 X Play 10 X Play Max Speed 2 0 X Play 2 0 X Play GPI CONNECTOR Version 6 x Software 15 Pin D Type Female DB15 F Version 6 x Software Rev 4 x
5. omer s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite D Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential o
6. r other types of damage resulting from the use of the product TH 12 ST100 VTR Controller
7. status LEDs turning ON Selecting LOCAL control on the VTR s front panel will turn OFF all status LEDs a RECORD MODE Four 4 record modes are available Crash Record Full Record Assemble Record Insert Record and Record Lockout Press only the RECORD switch to activate the selected Record mode The Record Status Indicator will light when the VTR is in RECORD mode NOTE The VTR will not go into Record mode if Record Inhibit is enabled on the VTR or tape cassette RECORD SELECTOR SWITCHES Mode 51 52 53 54 55 56 Record Lockout OFF OFF OFF OFF OFF OFF Assemble Record ON OFF OFF OFF OFF OFF Crash Record OFF ON OFF OFF OFF OFF Insert Record ON VID AUDI AUD2 AUD3 AUD4 Active On NOTE AUD3 amp AUD4 should be ON ONLY for VTRs that support 4 channels of audio i e D1 D2 and D3 type VTRs TIME CODE DISPLAY Display Timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR The Time Mode can be selected manually by pressing the SHIFT JOG keys each press will step to the next Time Mode CTL Tape Time Timecode VITC ST100 VTR Controller ST100 SXD FUNCTIONS The ST100 SXD is designed to work specifically with the Sony XDCAM The ST100 SXD includes support for clip access commands a GO TO FIRST CLIP Press SHIFT PLAY to go to the beginning of the first clip b GO TO LAST CLIP Press SHIFT STOP to go to the end of the last clip GO TO PREVIOUS CLIP Press SH
8. through All the functions you need at the press of a button Eliminates the need for multiple remote controllers and the associated clutter of several pieces of control hardware a FEATURES Timecode tape time display Jog Shuttle Wheel 12 function keypad provides the functions you need at the press of a button Small footprint desktop unit 8 1 2 x 5 V2 Can be easily customized for your specific needs Customize the ST100 with the transport control functions and status indicators you require for your specific applications Can be used through your facility s existing RS422 Control router RS422 patch bay or 9 pin switch box TIME CODE DISPLAY Display Timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR The Time Mode can be selected manually by pressing the SHIFT JOG keys each press will step to the next Time Mode CTL Tape Time Timecode VITC STANDARD FUNCTIONS RECORD PLAY STOP REWIND FAST FORWARD JOG SHUTTLE MODE SELECT NOTE JOG amp SHUTTLE WHEEL Active ONLY from STOP STILL or JOG SHUTTLE modes REAL TIME STATUS INDICATORS ACTIVE ON RECORD PLAY STOP STILL REWIND REVERSE FAST FORWARD FORWARD JOG MODE SELECTED ST100 VTR Controller 3 INSTALLATION a Plug one end of a 9 conductor RS422 serial cable into the 9 pin connector on the rear of the ST100 Plug the other end of the cable into the 9 pin remote connector on the VTR b Plug the 9 pin D
9. tion 13 GPI 4 In Rewind Command 26 No Connection POWER SUPPLY CONNECTOR 9 Pin D Type Male DB9M Pin 1 5Vdc Pn 6 5Vdc 2 5Vdc 7 Ground 3 Ground 8 Ground 4 No connection 9 Ground 5 No connection 9 57100 VTR Controller 7 TABLE TOP REAR AND TOP VIEW 1 POWER VIR GPI eje eT e Ere eost ON PIN1 5v PIN3 GND RESET Table Top Rear View 57100 UNIVERSAL VTR CONTROLLER sl UE RECORD PLAY STOP REWIND FFWD JOG Table Top Top View 10 ST100 VTR Controller RACKMOUNT FRONT AND REAR VIEW ST100 SRK Single Rackmount with Keypad T100 SRK Single Rackmount with Keypad FRONT PANEL REAR VIEW Loop THRU VTR THRU VTi POWER Gan 5 CONTRAST 11 ST100 VTR Controller 8 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the cust