Home

Second Generation Quad FXS Module User Manual (Rev A)

image

Contents

1. If the card is to be installed in a TSU 100 120 or 600 with an earlier software revision ADTRAN recommends that the TSU first be upgraded to the most recent revision to ensure proper operation with the FXS4 NOTE For assistance with software revision upgrades please contact ADTRAN Technical Support at 1 888 4ADTRAN For ease of replacement power to the TSU 100 120 600 may be On when installing or removing the FXS Quad option module 2 2 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 2 Installation Placement of the Option Module Figure 2 1 shows the proper placement of the option module To install the option module follow these steps Step Action 1 Remove cover plate from the TSU 100 120 600 rear panel 2 Slide option module into the rear panel until it is positioned firmly against the front of the TSU 100 120 600 unit 3 Fasten thumbscrews at both edges of the option module Cover Plate TSU 100 120 600 f Option Module Figure 2 1 Installing Option Module Power Connection Each FXS module derives power from the base TSU 100 120 600 unit Power to the TSU 100 120 600 is sup plied by a captive eight foot power cord 61202300L1 1 FXS Quad Voice Option Module User Manual 2 3 Chapter 2 Installation Wiring The FXS Quad option module analog voice interface connectors ar
2. 100 120 600 Main menu item Utilities UTIL displays the current software information for each port installed in the unit This infor mation is required when requesting assistance from ADTRAN Customer and Product Service or when up dates are needed When Port Utility displays place the cursor on it and press Enter to display the first available port See Figure 3 7 1 TIME DATE 2 FACTORY RESTORE 3 SET PASSCODE 5 SOFTWARE REV 6 PORT UTILITY 1 1 FXS 1 SW REVISION 2 COMMAND MODE UNIT ID Figure 3 7 Port Utility Submenus Display 1 1 FXS scroll to display if necessary and press Enter The unit displays the option module name and the software version installed The Port Utility submenu contains a second option Command Mode for the FXS module This option is re served for factory use only Press Cancel to exit or to select another port 3 14 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation Port Test 1 KHZ TONE Port Test a submenu of the TSU 100 120 600 Main menu item Test activates tests of the selected data ports Selecting the FSX displays tests available for this option module See Figure 3 8 below and Table 3 2 on page 3 16 1 NETWORK TESTS 1 1KHZ TONE 4 TEST 2 RUN SELF TEST 2 VIEW SIG BITS 3 PORT TEST 11 FXS 3 SET TX SIGNAL 4 CANCEL TEST 4 SET 2W OUTPUT Figure 3 8 Port Test S
3. DNIS Wink T o DNIS Wink Timeout When DNIS DELAY and DNIS WINK T O are both enabled the 5 option module winks to Telco if the equipment connected to the 2W does not answer within 5 seconds to an incoming call The wink timeout feature ensures that Telco will always see a response from the CPE even if there is no answer If this option is left disabled the 5 option module will not wink until the incoming call is answered Choices Enabled Disabled 3 12 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation Port Configuration Menu Items Parameters Summary Table 3 1 provides a summary of the Port Configuration menu items and their parameters Table 3 1 Port Configuration Parameters Menu Item Parameter Choices MODE FXS LS FXS GS TANDEM LS TANDEM GS PLAR SINGLE SLC96 UVG SLC96 RX LVL TLP 8 dB to 0 dB 1 dB steps 6dB TX LVL TLP 3 dB to 5 dB 1 DB steps 1 dB FAULT RESP Normal Seized ANSWER S VSN Disabled Enabled SUPERVISION Immediate Wink DIAL TONE Disabled Enabled LOOP REV BAT Disabled Enabled RINGBACK Disabled Enabled DNIS DELAY Disabled 0 5 to 5 seconds DNIS WINK T O Disabled Enabled Factory Default 61202300L1 1 FXS Quad Voice Option Module User Manual 3 13 Chapter 3 Operation PORT UTIL Port Utility 3 UTIL 4 Port Utility a submenu of the TSU
4. Loop Current specification 1 3 Loop Range specification 1 3 Loop Rev Bat port config menu item 3 13 loop reverse battery 3 11 Loop Reverse Battery tandem option 3 11 LSAS line side answer supervision 3 7 M Menu Operation 3 1 Index 1 Index Menu Structure of FXS module 3 1 MODE port config menu item 3 13 Operating Temperature specification 1 3 Operation Alarms 2 5 option module how to install 2 3 option module placement 2 3 Physical Description of FXS module 1 4 PLAR 3 8 PORT CONFIG Port Configuration 3 6 PORT CONFIG menu tree 3 6 Port Configuration Menu Items Parameters Summary 3 13 Port Configuration Submenus menu tree 3 6 Port Status 3 3 Port Status menu tree 3 3 Port Test 3 15 Port Test Parameters 3 16 Port Test menu tree 3 15 port utility menu tree 3 14 Power Connection 2 3 Power up testing 2 5 Power Up failure messages A 1 product warranty vi R repair and return information v revision level how to determine 2 2 Ring Generator specification 1 3 Ringback port config menu item 3 13 Ringback tandem option 3 11 Run Self Test TSU feature used with 5 op tions 3 17 Rx Idle Channel Noise specification 1 3 RX LVL TLP Receive Level Transmit Level Point 3 9 RX LVL TLP port config menu item 3 13 S Safety Instructions v self test failed 2 5 self test successful 2 5 Index 2 FXS Quad Voice Option Module User Manual SET 2 W OUTPUT
5. Messages The red ALARM LED with the module LEDs on the front panel illuminates when an alarm condition is detected 61202300L1 1 FXS Quad Voice Option Module User Manual 2 5 Chapter 2 Installation Configuration of TX Level TLP For any installation where the analog channel 050 ter minates within the Public Switched Telephone Network the TX LVL should be set to 3 dB For point to point ap plications where the channel terminates in other customer equipment any TX LVL may be used NOTE A 3 dB TLP setting attenuates the analog signal by 3 dB 2 6 FXS Quad Voice Option Module User Manual 61202300L1 1 3 Operation OVERVIEW Menu Structure Menu Operation The FXS module is controlled as part of the TSU 100 120 600 using the same methods described in the User Manual See the TSU 100 120 600 User Manual for descriptions of front panel indicators and buttons When an option module is installed in the TSU 100 120 600 the unit adds it to the list of available options under the Port menu items These menu items are shown in Fig ure 3 1 on page 3 2 An option module must be selected from a PORT MENU item before any of its menus are displayed With the cursor on one of the Port menu items press Enter to display a list of the currently installed option modules To activate menus for the FXS option module scroll through the list to display X 1 FXS and press Enter Once th
6. et ee etes 3 11 DNIS Wink DNIS Wink Timeout een 3 12 Port Configuration Menu Items Parameters Summary 3 13 PORT UTIL Port Utility een ree retient eee nee 3 14 Pott Testa oen erento RER ee nnd Ives Eee e e ean 3 15 TRHA TONE n Rte Een tee b e fene esed 3 15 VIEW SIG BITS View Signalling Bits sse 3 16 SET TX SIGNAL Set Transmit Signal sse 3 16 SET 2W OUTPUT Set 2 Wire Output sees eee 3 16 TSU Features Used With FXS Options 3 17 FACTORY RESTORE ertet deett a eri e e dde es 3 17 RUN SELFI ESI 1 32 2202 22 eere arte green 3 17 Appendix A FXS Failure Messages essent entente tnnt tne A 1 Appendix B Signalling States eese erret B 1 THX M Index 1 viii FXS Quad Voice User Manual 61202300L1 1 List of Figures Figure 1 1 Figure 2 1 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 61202300L1 1 FXS Quad Voice User Manual FXS Quad Option Modules sse eee 1 4 Installing Option Module sss 2 3 TSU Main Menu iin cite ee be o Ua ena 3 2 Port Status Submenus sse eene eene eene 3 3 2 Wire Status Display eret een 3 4 View Signalling Bits Display esee 3 5 SLC96 Status Display neos ent eee teens 3 5 Port Configuration
7. inter face is determined by the provisioning on the far side If Then the signalling for the T Span is set for Loop Start at the Digital Switch the FXS will have Loop Start supervision on the 2 wire inter face the signalling for the T Span is set for UVG Ground Start at the Digital Switch the FXS will have Ground Start supervision on the 2 wire inter face No other settings are necessary to configure the supervi sion as the far end determines it Channel Test signalling is ignored RX LVL TLP Receive Level Transmit Level Point RX LVL TLP sets the RX direction transmission level points TLP The TLP is indicated in dB and the relative loudness is indicated by a bar graph display Settings change immediately as the bar graph is scrolled Choice range 8 dB to 0 dB in 1 dB steps 61202300L1 1 FXS Quad Voice Option Module User Manual 3 9 Chapter 3 Operation TX LVL TLP Transmit Level Transmit Level Point TX LVL TLP sets the TX direction transmission level points TLP The TLP is indicated in dB and the relative loudness is indicated by a bar graph display Settings change immediately as the bar graph is scrolled Choice range 3 dB to 5 dB in 1 dB steps FAULT RESP Fault Response FAULT RESP is used to set the 2 wire response to a car rier alarm For a network alarm the ground start 2 wire trunk would appear busy if Fault Resp is set to seiz
8. states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream 1 0 logic 1 followed by a logic 0 in each successive signalling frame X value is not significant Loop Open phone on hook Loop Closed phone off hook 61202300L1 1 FXS Quad Voice Option Module User Manual B 3 Appendix Signalling States Table B 4 FXS Mode Ground Start FXS 2W RXA RXB TXA TXB FXS 2W Output Input Outgoing call from FXS 1 No Ring Gnd 1 1 0 1 Idle or Loop Open Ring Gnd 1 1 0 0 No Tip Gnd Ring Gnd or Loop Closed 0 1 1 1 Tip Gnd Loop Closed 0 1 0 0 1 Reverse Battery Loop Open 0 1 0 1 Tip Gnd Loop Open 1 1 0 1 Idle Incoming call to FXS Idle 1 X No amp No Ringing 0 1 Tip Gnd amp No Ringing Loop Open 0 1 0 1 Tip Gnd amp Ringing Loop Closed 0 0 1 1 Tip Gnd amp No Ringing The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream 1 0 logic 1 followed by logic 0 in each successive signalling frame X value is not significant Loop Open phone on hook Loop Closed phone off hook B 4 FXS Quad Voice Option Module User Manual 61202300L1 1 Appendix Signalling States Table B 5 Single Mode Input
9. ADRAN FXS Quad Voice Option Module Part Number 1202300L1 User Manual 61202300L1 1A July 2000 Trademarks MEGACOM is a registered trademark of AT amp T SLC96 is a registered trademark of AT amp T 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2000 ADTRAN Inc All Rights Reserved Printed in U S A NOTE Notes provide additional useful information Cautions signify information that could prevent service interrup CAUTION tion Warnings provide information that could prevent damage to the W ARNING equipment or endangerment to human life Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equip ment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio fre quencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter ference at his own expense Change or modifications to this unit not expressly aproved by the CAUTION party responsible
10. FXS 2W RXA RXB TXA TXB FXS 2W Output Outgoing call from FXS Loop Open X 1 0 0 No Ringing Idle Loop Closed X 1 1 0 No Ringing Loop Closed 1 0 1 0 1 0 Reverse Battery Incoming call to FXS Loop Open X 1 0 0 No Ringing Idle Loop Open X 1 0 Ringing Loop Closed X 1 1 0 No Ringing The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream 1 0 logic 1 followed by logic 0 in each successive signalling frame X value is not significant Loop Open phone on hook Loop Closed phone off hook 61202300L1 1 FXS Quad Voice Option Module User Manual B 5 Appendix Signalling States Table B 6 UVG Mode Loop Start Provisioning on T Span FXS 2W RXA RXB FXS 2W Input Output Outgoing call from FXS Loop Open X 1 0 No Ringing Idle Loop X 1 0 No Ringing Closed Loop 1 0 1 0 Reverse Closed Battery Incoming call to FXS Loop Open 0 1 0 No Ringing Idle Loop Open 0 1 0 Ringing Loop 0 1 0 No Ringing Closed The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream 1 0 logic 1 followed by logic 0 in each successive signalling frame X valu
11. Port Test Parameters Menu Item Parameter Choices 1 KHZ TONE Off Near Far VIEW SIG BITS Display only SET TX SIGNAL Off A 0 B 0 A 0 B 1 A 1 B 0 A 1 B 1 SET 2W OUTPUT Off Disabled Tip Open Active Reverse Battery Ringing 3 16 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation TSU Features Used With FXS Options FACTORY RESTORE RUN SELF TEST In addition to the FXS menu items two additional menu items of the TSU 100 120 600 may be operated in con junction with the FXS option module These are FACTO RY RESTORE and RUN SELF TEST FACTORY RESTORE a submenu of the TSU 100 120 600 Main menu item Utilities UTIL restores the factory installed default setting for all FXS option module pa rameters When FACTORY RESTORE displays place the cursor on it and press Enter The unit is restored to preset factory defaults and returns to the main TSU 100 120 600 menu The factory default for port configuration parameters in shown in Table 3 1 on page 3 13 RUN SELF TEST a submenu of the TSU 100 120 600 Main menu item TEST executes both the FXS internal test and the TSU 100 120 600 internal test The results of the self test are displayed in the LCD See the TSU 100 120 600 User Manual for additional information on Self Test When RUN SELF TEST displays place the cursor on it and press Enter to execute the test The unit continuously changes the dis
12. SRL gt 16 dB THL ERL gt 26 dB THL SRL gt 18 dB Longitudinal Bal gt 52 dB Rx Idle Channel Noise 15 dBrnc Tx Idle Channel Noise 20 dBrnc Loop Current 26 mA constant current Loop Range 0 500 Q Operating Temperature Connector 0 45 degrees C 95 humidity non condensing RJ 45 Ring Generator Sinusiodal 20Hz 75 Vrms 0 5 REN on band Ring Generator with 48 VDC off set 2 0 REN per port maximum Note The ring generator voltage is measured at 0 5 REN Tests Power on circuit test Signal bits monitoring and setting 1 kHz test tone generation Force 2 wire port output state 61202300L1 1 FXS Quad Voice Option Module User Manual 1 3 Chapter 1 Introduction PHYSICAL DESCRIPTION The FXS is an option module which plugs into the op tion slot in the rear of the TSU 100 See Figure 1 1 PORTX1 FXS em m HOT REPLACEABLE Figure 1 1 FXS Quad Option Modules The PORT X 1 indication is linked to the port numbering philosophy of the TSU 100 product family The X repre sents the slot number and the 1 indicates the port num ber For the TSU 100 application there is only one option slot Therefore the port designations for the Quad FXS Voice ports are 1 1 1 2 1 3 and 1 4 These port numbers will appear in the front panel LCD menu displays The remainder of the manual will refer to po
13. Self Test see TSU Features Used With FXS Options on page 3 17 The FXS menu items are discussed in the following pag es These items are e Port Status Port Configuration e Port Utility Port Test Port Status Port Status a submenu of TSU 100 120 600 Main menu item Status displays active status information about the FXS interface When Port Status displays place the cursor on it and press Enter to display the first available port See Figure 3 2 Scroll to select 1 1 FXS and press Enter to ac tivate one of the following submenus e 2W STATUS 2 wire status e VIEW SIG BITS View Signalling Bits e SLC96 STATUS 2 wire status when SINGLE modes 1 NI PERF REPORTS STATUS 2 NI ERRORS 3 ACTIVE ALARMS 4 VIEW HISTORY 5 PORT STATUS 1 1 FXS 2W STATUS 6 REMOTE PORT VIEW SIG BITS 7 CLEAR PORT ALM SLC96 STATUS Figure 3 2 Port Status Submenus 61202300L1 1 FXS Quad Voice Option Module User Manual 3 3 Chapter 3 Operation 2W STATUS 2 Wire Status Contains two information fields Busy and Ringing as shown in Figure 3 3 An asterisk indicates an item is active Figure 3 3 2 Wire Status Display Busy An asterisk is present if loop current is flowing through the 2 wire circuit Ringing An asterisk is present if ringing voltage is being applied to the 2 wire circuit from the ring generator on the FXS option module 3 4 F
14. Set 2 Wire Output 3 16 Set TX SIGNAL Set Transmit Signal 3 16 shipping damages what to do 2 1 Signaling states vs mode of operation B 1 signalling states B 1 Single Party supported by 5 option modules 1 1 SINGLE SLC96 3 8 SLC96 STATUS Single and UVG Status 3 5 SLC96 Status example 3 5 software revision upgrades assistance with 2 2 Specifications 5 Option Module 1 3 Supervision port config menu 3 13 Supervision tandem option 3 10 T TANDEM GS 3 8 TANDEM LS 3 7 TANDEM LS loop reverse battery 3 11 Tandm options 3 10 Tests specification 1 3 THL ERL specification 1 3 THL SRL specification 1 3 Tip and Ring polarity LS 3 7 Transmission Levels specification 1 3 TSU Main Menu 3 2 TSU Menu Tree 3 2 Tx Idle Channel Noise specification 1 3 TX LVL TLP Transmit Level Transmit Level Point 3 10 TX LVL TLP port config menu item 3 13 U Universal Voice Grade 3 9 UVG SLC96 3 9 V VIEW SIG BITS View Signalling Bits 3 5 VIEW SIG BITS View signalling Bits 3 16 View Signaling Bits Display 3 16 Voice Channels specification 1 3 Warranty and Customer Service Wiring connection for modules 2 4 61202300L1 1 Product Support Information Presales Inquiries and Applications Support Please contact your local distributor ADTRAN Applications Engineer ing or ADTRAN Sales Applications Engineering 800 615 1176 Sales 800 827 0807 Post Sale Support Please contact you
15. Submenus sss 3 6 Port Utility SUBMENUS tee ete tene eet 3 14 Port Test Submenus sess nnne 3 15 View Signalling Bits Display sse 3 16 List of Figures x FXS Quad Voice User Manual 61202300L1 1 List of Tables Table 2 1 2 Wire Voice Pinout Connection esee 2 4 Table 3 1 Port Configuration Parameters esses 3 13 Table 3 2 Port Test ennt entren 3 16 Table B t Pl r Mode one Re e ee Ee ee B 1 Table B 2 Tandem Modes sse eere eere nnn rnnt B 2 Table B 3 FXS Mode LoopoStart sssssssssesee ee eene B 3 Table B 4 FXS Mode Ground Start seen B 4 Table B gt Single Mode ue ene ea B 5 Table B 6 Mode Loop Start Provisioning on T Span B 6 Table B 7 UVG Mode Ground Start Provisioning on T Span B 7 61202300L1 1 FXS Quad Voice User Manual xi List of Tables xii FXS Quad Voice User Manual 61202300L1 1 Chapter 1 Introduction FXS QUAD VOICE OVERVIEW FXS Uses The FXS Quad Voice option modules can be used with the ADTRAN TSU 100 120 600 The Quad FXS module provides four 2 wire voice grade interfaces serving as the source of line current and ringing voltage to a tele phone or station interface The FXS may serve as the station side of a foreign ex change FXS FXO
16. TRAN s express written permission This warranty becomes null and void if Customer modifies or alters the equip ment in any way other than as specifically authorized by ADTRAN EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE THE FORE GOING CONSTITUTES THE SOLE AND EXCLUSIVE REMEDY OF THE CUS TOMER AND THE EXCLUSIVE LIABILITY OF ADTRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ADT RAN SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES INCLUDING WITHOUT LIMITATION ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THIS EXCLU SION MAY NOT APPLY TO CUSTOMER In no event will ADTRAN or its suppliers be liable to Customer for any inciden tal special punitive exemplary or consequential damages experienced by either Customer or a third party including but not limited to loss of data or information loss of profits or loss of use ADTRAN is not liable for damages for any cause whatsoever whether based in contract tort or otherwise in excess of the amount paid for the item Some states do not allow the limitation or exclusion of liability for incidental or consequential damages so the above limitation or exclusion may not apply to Customer vi Table of Contents Ipcqoguriv ix List Of Ta me ECT EN xi Chapter 1 Introduction eese eet seese tn tata ntn tn tata
17. XS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation VIEW SIG BITS View Signalling Bits Use VIEW SIG BITS to view the status of the RX and TX signalling bits in the DS 1 stream See Figure 3 4 If you are operating in a SLC96 mode 1 0 may be displayed This means that the signalling bit is toggling in each suc cessive frame for that port Figure 3 4 View Signalling Bits Display SLC96 STATUS Single and UVG Status SLC96 Status is used to view the signalling states on a per channel basis related to the Channel Network Interface and the Customer 2W Ports The states are shown in lexical representation to aid in determining system status without monitoring and translating the signalling bits VIEW SIG BITS SLC96 STATUS is only available when SINGLE or UVG modes of operation are selected See Figure 3 5 Figure 3 5 SLC96 Status Display 61202300L1 1 FXS Quad Voice Option Module User Manual 3 5 Chapter 3 Operation PORT CONFIG Po 2 CONFIG rt Configuration Port Configuration a submenu of TSU 100 120 600 main menu item Configuration is used to configure the FXS option module The following submenu items are used to configure the parameters e MODE e RXLVL TLP e TXLVL TLP e FAULT RESP e ANSWER S VSN OPTIONS Supervision Dial Tone Loop Rev Bat Ringback DNIS Delay DNIS Wink Timeout When Port Configuration dis
18. application It may be paired with an other FXS to provide a hotline or private line automatic ringdown PLAR function to a remote location at the far end of the T Span When the FXS is used in the tandem mode it can be set to accept phone service directly from a toll switch using E amp M signalling on the T Span e g 1 800 services Mega com It may also be used to provide trunk services to a PBX from a local switch The FXS is intended for use in applications where the 2 wire port wiring remains on premises The FXS option modules support Single Party and Uni versal Voice Grade UVG Channel Unit Operation as speci fied by TR TSY 000008 The FXS module and a TSU 600 600e can act as a remote terminal in a digital loop carrier application Signalling and interfaces comply with por tions of EIA TIA 464 A T1 401 and AT amp T Pub 41458 and Pub 43801 61202300L1 1 FXS Quad Voice Option Module User Manual 1 1 Chapter 1 Introduction Functional Description Features The FXS is designed to fit in the option slot of the TSU 100 120 600 and is subject to its operation and control The FXS is configured from the front panel of the TSU 100 120 600 or by an external personal comput er PC program The internal menus for its configuration are a part of the FXS module and are automatically installed when the FXS is plugged into the unit The 5 option module has the following features Each 2 wire
19. ce Option Module User Manual B 1 Appendix Signalling States Ground start signalling provides its own tip ground in re sponse to ring ground in the Tandem Mode See Table B 2 Table B 2 Tandem Modes FXS 2W Input RXB TXA TXB FXS 2W Switch to FXS Output Condition Outgoing call from FXS 1 Loop Open 0 X 0 0 n Idle Loop Closed 0 x 1 1 M Idle Loop Closed 1 X 1 1 Dial Tone Wink Loop Closed 0 X 1 1 Wink Done Loop Closed 1 x 1 1 _ Answer Far End Incoming call to FXS Loop Open 0 x 0 0 Idle Loop Closed 1 X 0 0 Ringing Far end off hook Loop Closed 1 X 1 1 Answers Far end off hook The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream X value is not significant Loop Open phone on hook Loop Closed phone off hook B 2 FXS Quad Voice Option Module User Manual 61202300L1 1 Appendix Signalling States Tables B 3 through B 7 describe various modes for signal ling states Table B 3 FXS Mode Loop Start FXS 2W Input RXA RXB TXA TXB FXS 2W Output Outgoing call from FXS Loop Open X 1 0 1 No Ringing Idle Loop Closed X 1 1 1 No Ringing Loop Closed X 1 0 1 1 Reverse Battery Incoming call to FXS Loop Open X 0 0 1 Ringing Loop Closed X 1 1 No Ringing The A and B signal bit
20. e e E ERE de te 3 1 Menu Op ration eU eater etr mae cH 3 1 FXS Men Items ee RE re e Hein 3 3 61202300L1 1 FXS Quad Voice User Manual vii Table of Contents Port Status aos Be Euer e ee hel fee bel 3 3 2W STATUS 2 Wire Status ai ii 3 4 VIEW SIG BITS View Signalling Bits eese 3 5 SLC96 STATUS Single and Status 3 5 PORT CONFIG Port Configuration sees eee 3 6 MONDE 3 cete mese tute cete tette aee re teen 3 7 EXS LS Dt 3 7 E E E 3 7 UES 1st teet Hotte HER ete lieti ul 3 7 TANDEM GO eines te ieu E NAA A ter P east 3 8 2 eee iret Eee hie 3 8 SINGEE STEB6 4 ee ra tr le te esee 3 8 UVG SLEG396 2 Dee tere tiber beetle see eee eden 3 9 RX LVL Receive Level Transmit Level Point 3 9 TX LVL Transmit Level Transmit Level Point 3 10 FAULT RESP Fault Response ssseeeeeeee ene 3 10 ANSWER S VSN Line Side Answer Supervision 3 10 OPTIONS Tandem Options 2 eee 3 10 SUPELVISION sn een nennen 3 10 Dialtorie denen rt kn en den 3 11 Loop Rev Bat Loop Reverse Battery 3 11 he 3 11 Dris Delay iet RH
21. e far end FXS_GS This mode sets the port to use FXS ground start supervi sion on the analog 2 wire interface Ground start opera tion is often used with trunk interfaces to PBS and key systems to prevent glare conditions Ringing cadence will follow that provided over the T Span or detected by the FXO port at the far end Line Side Answer Supervi sion is also supported TANDEM LS This mode sets the port to use E amp M signalling on the T Span and loop start supervision or on the analog 2 wire interface When using this mode line current dropout for 500 ms is provided when a call terminates and the far end hangs up This may be useful for voice mail or modem systems that need far end disconnect supervision This mode also 61202300L1 1 FXS Quad Voice Option Module User Manual 3 7 Chapter 3 Operation requires other options to be selected These options are Supervision on page 3 10 Dialtone on page 3 11 Loop Rev Bat Loop Reverse Battery on page 3 11 Ringback on page 3 11 Dnis Delay on page 3 11 and on DNIS Wink T o DNIS Wink Timeout on page 3 12 Ringing cadence for incoming calls is two seconds on four seconds off TANDEM_GS This mode sets the port to use E amp M signalling on the T Span and ground start supervision on the analog 2 wire interface Ground start operation is often used with trunk interfaces to PBX and key systems to prevent glare conditions Appropriate TANDM OPTIONS must be cho sen in t
22. e is not significant Loop Open phone on hook Loop Closed phone off hook B 6 FXS Quad Voice Option Module User Manual 61202300L1 1 Appendix Signalling States Table B 7 UVG Mode Ground Start Provisioning on T Span FXS 2W RXB TXA TXB FXS 2W Output Input Outgoing call from FXS Loop Open 0 0 0 0 No Ringing Ground Start Ring Ground 0 0 0 1 No Tip Ground Loop Closed 0 1 0 1 0 Tip Ground Loop Closed 1 0 1 0 1 0 Reverse Battery Incoming call to FXS Ground Start 0 0 0 0 No Ringing Loop Open 1 1 0 0 0 Tip Ground amp Ringing Loop Open 0 1 0 0 0 Tip Ground amp No Ringing Loop Closed 0 1 0 1 0 Tip Ground amp No Ringing The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream 1 0 logic 1 followed by logic 0 in each successive signalling frame X value is not significant Loop Open phone on hook Loop Closed phone off hook 61202300L1 1 FXS Quad Voice Option Module User Manual B 7 Appendix Signalling States B 8 FXS Quad Voice Option Module User Manual 61202300L1 1 Index Numerics 2W STATUS 2 Wire Status 3 4 2 Wire ERL specification 1 3 2 Wire impedance specification 1 3 2 Wire SRL specification 1 3 2 Wire Status Display 3 4 2 Wire Voice Pinout Connection 2 4 A ADTRAN Technical Su
23. e option module is selected the FXS menus ap pear as a subset of and operate the same as menus for the TSU 100 120 600 With the cursor on one of the TSU 100 61202300L1 1 FXS Quad Voice Option Module User Manual 3 1 Chapter 3 Operation 120 600 four main menu choices press Enter or a menu number to display the first two submenu items Use the up and down arrows to place the cursor on the de sired item and press Enter to display the first two sub menu choices NI PERF REPORTS 1 STATUS 2 NI ERRORS 3 ACTIVE ALARMS 1 NETWORK NI 4 VIEW HISTORY 2 UNIT 5 PORT STATUS 2 CONFIG 3 MAP XCHANG 6 REMOTE PORT 4 MAPINUSE A B 7 CLEAR PORT ALM 5 DS0 MAP A TSU 100 6 DS0 MAP B MAIN MENU 7 PORT CONFIG 1 TIME DATE 2 FACTORY RESTORE 3 SET PASSCODE 3 UTIL 4 UNIT ID 5 SOFTWARE REV 1 NETWORK TESTS 6 PORT UTILITY 4 TEST 2 3 4 RUN SELF TEST PORT TEST CANCEL TEST lt Figure 3 1 TSU Main Menu Additional item menus may be displayed on the TSU 600 600e products NOTE 3 2 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation FXS Menu Items The FXS menus are accessed from and operate the same as menus for the TSU 100 120 600 The FXS items are submenu choices of the TSU 100 120 600 four main menus as shown in Figure 3 1 on page 3 2 For informa tion on Factory Restore and Run
24. e universal and accept either an RJ 45 8 pin modular plug or an RJ 11 6 pin modular plug The pinout is shown in Table 2 1 The required wiring connection is Connector Type USOC RJ 45 Part number AMP 555164 1 Table 2 1 2 Wire Voice Pinout Connection Pin Name Description 5 Tip Tip lead of 2 wire interface 4 Ring Ring lead of 2 wire interface 1 2 3 6 7 8 Unused Pins used to mate with FXS connector are as follows Connector Pin RJ 11 Tip 4 Ring 3 RJ 45 Tip 5 Ring 4 2 4 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 2 Installation POWER UP TESTING AND INITIALIZATION The FXS option module executes an abbreviated self test during the power up sequence as described in the TSU 100 120 600 User Manual Any previously configured setting for the FXS is restored automatically upon power up Successful Self Test Failed Self Test Operation Alarms The green OK LED located with the module LEDs on the front panel illuminates when a successful self test is com pleted and the configuration is successfully restored See the Front Panel Operation section in the TSU 100 120 600 User Manual If the FXS module fails one or more of the self tests a message displays in the LCD during power up See the TSU 100 120 600 User Manual for more information Specific failures of the FXS module are identified in Ap pendix A FXS Failure
25. ed If set to normal no seizure of a ground start trunk occurs Choices Normal Seized ANSWER S VSN Line Side Answer Supervision ANSWER S VSN is used to signal the 2W interface when the far end NI has gone OFFHOOK When the far end is OFFHOOK the FXS reverses polarity on the 2W inter face This option is valid for all modes of operation except PLAR Enabling ANSWER S VSN will not cause polarity reversal on the 2W when receiving a wink in TANDEM modes Use the LOOP REV BAT setting to respond to a wink Choices Enable Disabled TANDM OPTIONS Tandem Options Some options are valid only when operating in the tan dem mode These options are provided below Supervision Supervision sets the supervision method used when the card is configured to operate in the Tandem mode Choices Immediate Wink 3 10 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation Dialtone DIALTONE is used to enable or disable the on board dial tone generation when the 5 is operating in the tandem mode When the on board dial tone generation is enabled the dial tone will turn off after a five second time out Choices Enabled Disabled Loop Rev Bat Loop Reverse Battery In TANDEM LS mode this option reverses Tip and Ring polarity when OFFHOOK is received from the far end The Loop Reverse Battery responds to Winks and Off hook signals Use ANSWER S VSN to respond only to the far end going OFFHOOK Lo
26. for compliance could void the user s authority to operate the equipment CANADIAN EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class A limits for radio noise emis sions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Department of Commu nications Cet appareil nuerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Class A prescrites dans la norme sur le materiel brouilleur Appareils Numeriques NMB 008 edictee par le ministre des Com munications Important Safety Instructions When using your telephone equipment please follow these basic safety precau tions to reduce the risk of fire electrical shock or personal injury 1 Do not use this product near water such as near a bath tub wash bowl kitchen sink laundry tub in a wet basement or near a swimming pool 2 Avoid using a telephone other than a cordless type during an electri cal storm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord power supply and or batteries indicated in the manual Do not dispose of batteries in a fire They may explode Check with local codes for special disposal instructions SAVE THESE INSTRUCTIONS WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five yea
27. his mode as described for TANDEM_LS NOTE The Loop Reverse Battery is not applicable in this mode Ringing cadence for incoming calls is two seconds on four seconds off PLAR This mode sets the port to use PLAR signalling on the T Span and loop start supervision on the analog 2 wire interface This mode is used to provide a point to point hot line so that when one telephone is lifted off hook the telephone at the other end rings until it is also picked up When both ends are off hook a direct point to point con nection is established Ringing cadence istwo seconds on four seconds off SINGLE SLC96 This mode sets the port to use Single Party channel unit signalling on the T Span as defined by TR TSY 000008 and Loop Start supervision on the analog 2 wire inter face This mode is used in a Digital Loop Carrier configu 3 8 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation ration when the TSU FXS combination acts as the Remote Terminal Channel Test signalling is ignored and the Forward Dis connect feature is implemented by removing tip ground during the call Line Side Answer Supervision is also supported UVG SLC96 This mode of operation will configure the port to use Universal Voice Grade signalling on the T span as defined by TR TSY 000008 and either Loop Start or Ground Start Supervision on the analog 2 wire interface LSAS is supported The supervision on the 2 wire
28. op Reverse Battery is used to emulate DPO functionality Choices Enabled Disabled Ringback This option generates ringback tone towards the T Span when enabled and the 5 card is in one of the tandem modes This may be needed in cases where the network does not provide ringback tone Choices Enabled Disabled Dnis Delay The option allows the FXS to be used in applications such as automatic voice mail or paging systems with telephone interfaces for POTS lines The DNIS Delay option allows routing information to be supplied to these systems from the Central Office CO The FXS is placed in TANDEM LS or TANDEM GS mode as required by the Customer Premises Equipment CPE Supervision must be set to WINK mode Signal ling conversion between the DID protocol expected by the CO and POTS signalling on the 2 wire interface is made by the FXS After the CO seizes the trunk the FXS waits for the CPE to go off hook and then sends a wink After the wink the FXS waits for the amount of time set by DNIS delay then sends answer supervision toward the CO 61202300L1 1 FXS Quad Voice Option Module User Manual 3 11 Chapter 3 Operation The CPE must be able to answer calls within a carrier specified time usually 5 seconds receive digits immedi ately on answer and route calls to their destinations within the time set by DNIS delay Choices Disabled 0 5 sec 1 0 sec 1 5 sec 2 0 sec 2 5 sec 3 0 sec and 5 0 sec
29. play in the LCD window until all test re sults are shown 61202300L1 1 FXS Quad Voice Option Module User Manual 3 17 Chapter 3 Operation 3 18 FXS Quad Voice Option Module User Manual 61202300L1 1 Appendix A FXS Failure Messages FAILURE MESSAGES AT POWER UP The following messages indicate a probable component failure on the FXS Module E01 EPROM CS EPROM checksum error E02 RAM ERR Static RAM error E10 SIGNALING Failure of signal bit transmission FXS Alarm Messages No alarms are specified for the FXS Voice option mod ule 61202300L1 1 FXS Quad Voice Option Module User Manual A 1 Appendix FXS Failure Messages A 2 FXS Quad Voice Option Module User Manual 61202300L1 1 Signalling States SIGNALLING STATES VS MODE OF OPERATION The tables in this appendix describe the signalling states for voice card and the DS 1 PCM stream Ground start signalling is not used in PLAR mode See Table B 1 Table B 1 Plar Mode FXS 2W Input Loop Open Loop Closed Loop Open Loop Open Loop Closed RXA RXB TXA TXB FXS 2W Output 1 1 i 0 0 1 1 No Ringing 1 1 Ringing 0 0 No Ringing The A and B signal bit states on the DS 1 signal are as fol lows Signal Means 0 logic 0 is the DS 1 stream 1 logic 1 is the DS 1 stream X value is not significant Loop Open phone on hook Loop Closed phone off hook FXS Quad Voi
30. plays place the cursor on it and press Enter to activate Scroll to display the port to be configured and press Enter See Figure 3 6 The unit displays the first of five submenu items Table 3 1 on page 3 13 identifies the available selections for Port Configuration Continue with standard operat ing procedure 1 2 7 PORT CONFIG 1 2 FXS 3 MODE RX LVL TLP TX LVL TLP 4 5 6 FAULT RESP ANSWER S VSN TANDM OPTIONS KS FS Hy NH Figure 3 6 Port Configuration Submenus 3 6 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 3 Operation MODE Mode sets the type of 2 wire to 1 signalling and supervi sion to be used Choices include FXS_LS This mode sets the port to use FXS loop start signalling on the T Span and loop start supervision on the analog 2 wire interface It also supports far end disconnect by removing tip ground during the call if signalled to do so over the T Span When used with an ADTRAN FXO this feature allows line current dropouts to be passed on to equip ment connected to the FXS 2 wire port Line Side Answer Supervision LSAS reverses Tip and Ring polarity when a call originated from the FXS is answered To use this feature ANSWER S VSN must be enabled and the port must receive Reverse Loop Current Feed RLCF signalling on the T span Ringing cadence will follow that provided over the T Span or detected by the FXO port at th
31. port operates at 64 kbps 1 050 Supports loop resistances to 500 Menu configurable Tx and Rx levels FXS PLAR Tandem Single Party and Universal Voice Grade operating modes Ground Start or Loop Start signalling Wink or Immediate Supervision in Tandem mode Wink delay for ANI DNIS services Integral ringback and dial tone generation Integral sinusoidal 20 Hz ring generation Extensive testing capabilities such as Rx and Tx signal bit monitoring SLC96 Status monitoring Busy and Ringing status monitoring Integral 1 KHz tone generation sends test tone toward near or far end Manual control of Tx A and Tx B signal bits Manual control of 2 wire interface supervision out put Selectable response during carrier failure 1 2 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 1 Introduction e Full V 90 modem connect capability 56 6 kbps e Provides FXS forward disconnect capability e Line Side Answer Supervision LSAS is supported for FXS LS FXS GS TANDEM LS TANDEM GS Single and UVG modes of operation e Hot replaceable FXS Option Module Specifications The FXS option module conforms to the following spec ifications Voice Channels Transmission Levels 4 TX 3 to 5 dB TLP 1 dB steps RX 0 to 8 dB TLP 1 dB steps Frequency Response 300 3400 Hz 1 0 dB 2 Wire Impedance 600 Q 2 15 uF 2 Wire ERL gt 26 dB 2 Wire
32. pport 2 2 ANSWER S VSN 3 7 3 10 ANSWER S VSN port config menu item 3 13 C Configuration of TX Level TLP 2 6 Connector specification 1 3 Customer Service v D Dial Tone port config menu item 3 13 DIALTONE tandem option 3 11 DNIS Delay port config menu item 3 13 DNIS Delay tandem option 3 11 DNIS WINK T O 3 12 DNIS Wink T O port config menu item 3 13 DNIS Wink Timeout 3 12 E E01 EPROM CS 1 E02 RAM ERR A 1 E10 SIGNALING A 1 F Factory Restore TSU feature used with 5 op tions 3 17 Failure Messages at Power Up A 1 Fault Resp Fault Response 3 10 FAULT RESP port config menu item 3 13 61202300L1 1 FXS Quad Voice Option Module User Manual FCC Radio Frequency Interference Statement iv Features for FSX option module 1 2 Frequency Response specification 1 3 Functional Description FXS 1 2 FXS Alarm Messages A 1 FXS connector pins 2 4 FXS module overview 3 1 FXS Option Module Specifications 1 3 FXS option module features 1 2 FXS option module specifications 1 3 FXS Options features 3 17 FXS Quad overview 1 1 FXS description 1 2 FXS physical description 1 4 FXS used in tandem mode 1 1 FXS_GS 3 7 FXS_LS 3 7 inspection 2 1 installing option module how to 2 3 Items Provided by Customer 2 1 Items Shipped by ADTRAN 2 1 L Line Side Answer Supervision 1 3 3 7 3 9 Line Side Answer Supervisor ANSWER S VSN 3 10 Longitudinal Bal specification 1 3
33. r local distributor first If your local distributor can not help please contact ADTRAN Technical Support and have the unit serial number available Technical Support 888 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed Tech nical Support will coordinate with the Customer and Product Service CAPS department to issue an RMA number For information regard ing equipment currently in house or possible fees associated with repair contact CAPS directly at the following number CAPS Department 256 963 8722 Identify the RMA number clearly on the package below address and return to the following address ADTRAN Customer and Product Service 6767 Old Madison Pike Progress Center Building 6 Suite 690 Huntsville AL 35807 RMA
34. rs from the date of shipment if the product does not meet its published specifications or if it fails while in service For detailed warranty repair and return information see the ADTRAN Equipment Warranty and Repair and Return Policy Procedure on the inside back page of this manual Return Material Authorization RMA is required prior to returning equipment to ADTRAN For service RMA requests or more information contact one of the numbers found on the inside back page of this manual LIMITED PRODUCT WARRANTY ADTRAN warrants that for five 5 years from the date of shipment to Cus tomer all products manufactured by ADTRAN will be free from defects in materials and workmanship ADTRAN also warrants that products will con form to the applicable specifications and drawings for such products as con tained in the Product Manual or in ADTRAN s internal specifications and drawings for such products which may or may not be reflected in the Product Manual This warranty only applies if Customer gives ADTRAN written notice of defects during the warranty period Upon such notice ADTRAN will at its option either repair or replace the defective item If ADTRAN is unable in a reasonable time to repair or replace any equipment to a condition as war ranted Customer is entitled to a full refund of the purchase price upon return of the equipment to ADTRAN This warranty applies only to the original pur chaser and is not transferable without AD
35. rt numbers as 1 1 or X 1 for illustrative purposes 1 4 FXS Quad Voice Option Module User Manual 61202300L1 1 Chapter 2 Installation UNPACK AND INSPECT Carefully inspect the FXS Quad Voice option module for any shipping damages If damage is suspected file a claim immediately with the carrier and then contact ADT RAN Customer and Product Service CAPS See the last page of this manual If possible keep the original ship ping container for use in shipping the FXS module back for repair or for verification of damage during shipment Items Shipped by ADTRAN e FXS Quad option module e FXS Quad Option Module User Manual to be inserted into the main TSU 100 120 600 manual Items Provided by Customer e Cable to connect the unit to the station 61202300L1 1 FXS Quad Voice Option Module User Manual 2 1 Chapter 2 Installation INSTALLING THE FXS VOICE OPTION MODULE Determine Revision Level of TSU 100 120 600 All TSU chassis support the FXS Quad option module TSU 100 units must have Software Revision L or later and the TSU 600 1200076L1 and 1200076L2 must have Soft ware Revision F or later To determine the revision level do the following Step Action Result 1 Power on the TSU 2 Using the front panel keypad The Utility Menu displays select item 3 UTIL 3 From the Utility Menu select The unit displays the revision Software Revision of the operating software
36. tnos as 1 1 FXS Quad Voice Overview eese ennt tnnt erret 1 1 EXS E Useszs cci ee eatem ineat nal shake 1 1 Functional Description iet ne tee es 1 2 inier ee pe EO o de Er aedes 1 2 FXS Option Module Specifications sss 1 3 Physical D scription 5 te eee atten cepe iet e rere p ep Ro re e ERI Pea 1 4 Chapter 2 Installation eee i a tata nono on tn 2 1 Unpack and inspect eter ee nete treu fee tei ttt ee dee ee e ae 2 1 Items Shipped by ADTRAN seeeeeee eene ee nen n nennen 2 1 Items Provided by Customer see eee eee nennen 2 1 INstalling the FXS Voice Option Module eee 2 2 Determine Revision Level of TSU 100 120 600 2 2 Placement of the Option Module sss 2 3 Power Connect Ons p cv re Sheed 2 3 hn 2 4 Power Up Testing And Initialization sese eee en 2 5 Successful Self Test eese esee entere tenente tenet 2 5 Failed Self T st iieri reete ed e pete eo HERE 2 5 Op ration Alarms iini nee one eot ded irn 2 5 Configuration of TX Level TLP sese nennen 2 6 Chapter 3 Operation ccssssssssssssssscseseccssessesescecesssseseesssessesesensesessesessesesesoeseees 3 1 COV OEVICW eet En e E ROT RAE EHI pe epi RES 3 1 structure nete cete
37. ubmenus When Port Test displays place the cursor on it and press Enter to display the first available port Scroll to select 1 1 FXS and press Enter to activate the following submenu items e 1KHZ TONE e SIG BITS e SET TX SIGNAL e SET 2W OUTPUT These items are discussed on the following pages This test injects a 1 KHZ SINE WAVE either toward the far end TX direction toward the T1 network or toward the near end the 2 wire interface on the option module This tone may be used for testing or relative level measure ments When 1 KHZ TONE is enabled ringing and dial tone for other channels on the slot are suspended Choices Off Near Far 61202300L1 1 FXS Quad Voice Option Module User Manual 3 15 Chapter 3 Operation VIEW SIG BITS View Signalling Bits VIEW SIG BITS is used to view the status of the RX and TX signalling bits in the DS 1 stream See Figure 3 9 If you are operating in a SLC96 mode 1 0 may be displayed This means that the signalling bit is toggling in each suc cessive frame for that port The status of both the A and B bits is displayed Figure 3 9 View Signalling Bits Display SET TX SIGNAL Set Transmit Signal SET TX SIGNAL allows the A and B signal bits in the TX direction to be forced to a desired state for test SET 2W OUTPUT Set 2 Wire Output SET 2W OUTPUT allows the 2 wire voice interface out put to be forced to a desired state for test Table 3 2