Home

User manual IW36-3

image

Contents

1. Manufacturer will not with responsibility for those operation not according to this Instruction e Verify that the voltage matches the rated voltage e When the voltage is 110V Do not connect more than 10 lightings in total to AC mains power in one interconnected daisy chain e When the voltage is 220V Do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain e Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices e Always ground earth the fixture electrically e Avoiding hit the Light when you are move or install the light e The minimum distance between light output and the illuminated surface must be more than 0 5 meters Keep all combustible materials for example fabric wood paper at least 0 2 meters away from the fixture e Do not expose the fixture to rain or moisture e Avoid looking directly into the light source especially those who suffer from epileptic fits e Maximum ambient temperature Ta is 40 C Do not operate fixture at temperatures higher than this e The Maximum surface temperature is 50 C e When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices e Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary a
2. 9 No function 250 255 Illuminate display Cool white dimmer Warm white dimmer 4 Channels Mode CH1 Cool white dimmer m 000 255 0 100 CH2 Warm white dimmer 000 255 0 100 CH3 Pan 000 255 0 540 0 630 REDE the maximum angle base in the setting in menu CH4 Tilt l fo __ _ _ Button Call the main menu or escape the current menu i e return to the upper menu and give up the selected item or parameter Browse the menu item forward or increase the parameter Browse the menu item backward or decrease the parameter er jj g li e Y LE F E i NTER Confirm the selected item or parameter i e enter the next menu or escape the current menu and save the selected item or parameter Menu Menu navigation OSET menu SET menu SET menu SET menu SET menu SET menu SET menu SET menu SET menu SET Addr 001 DMX mode ENTER gt DMX Menu UP t DOWN SET ManualDimmer ENTER gt ManualDimmer Menu UP tf DOWN SET AllWhite ENTER gt Null UP tf DOWN SET 3200K ENTER gt Null UP 1 DOWN SET 5600K ENTER gt Null UP 1 DOWN SET 6500K ENTER gt Null UR 1 DOWN SET 8500K ENTER gt Null UP t DOWN SET 10000K ENTER gt Null UP 1 DOWN SET Twinkling ENTER gt Motor Run Menu UP t DOWN SET menu SET Menu FReset Machine FReset ON LReset OFF Load Parameter Load ON ELoad OFF Master Alone Mas
3. FDMX Address 001 No DMX Signal Stop Run Hold Run Auto Run DMX Channels STAGE Mode HO Channels L4 Channels 3 ManualDimmer menu ManualDimmer LLight Switch Light ON Light OFF LLight Cool 000 LLight Warm 000 LLight Strobe 000 FScan Pan 128 FScan Tilt 128 Scan PanFine 000 FScanTiltFine 000 LI ight Calibrate Cal Pan 128 127 LCal Tilt 128 127 DMX mode Set DMX address Run if there is no DMX signal default default default Cool white dimmer 0 255 default 255 Warm white dimmer 0 255 default 255 default 0 default 0 default 0 default 0 default 0 Pan calibration default 0 Tilt calibration default 0 Motor Run Menu Motor Run Menu Motor Run Motor automatically run or not Auto Run OFF Motor do not run Auto Run ON Motor automatically run Technical parameters Rated voltage 100 240V Rated frequency 50 60Hz Power 130W LED 3W CREE XP E LED lifespan about 50 OOOhours LED quantity 24 warm white 12 cool white Beam angle 8 Rotation Angle Pan 540 630 Tlit 240 self correcting Channel quantity 9 or 4 depend on setting in menu Control mode DMX512 Master slave Protection grade IP20 Working environment indoor Environment temperature 30 40 C Size L242 W130 H289mm Weight 3 6kg
4. Fil 1 IGHTING User manual IW36 3 White L Please read the manual before installing and using this lighting Keep it for future reference Contents FPO GUC TION A men y a ani E si k n e saan da carl b e idnscetaensaanias 2 OVERVIEW and DIMENSIONS cy 42542 hE yA ide 3 SATS sa Oa AAA E TO O 4 POW EE COL n C L OT aaa ia 5 PMA protocolo tii 7 But a rd 9 ME none 10 Technical parameter dla 14 Introduction Thank you for using our products LM 2012 is a very small and light LED Moving head light its weight 1s only 3 6 kg Its beam is very narrow and very bright It runs extremely fast It is suitable for bar disco stage decoration etc This product complies with the following standards TEC60598 1 2003 TEC60598 2 17 1984 A2 1990 Main features 36 Pcs high power 3W CREE XP E LED Excellent mixed color system Linear adjustment dimmer very smooth Tight punchy beam compact silent design Speedly Blue LCD display Standar DMX 512 communication protocol Easy for power connection Overview and Dimensions LCD display Button E lf a Ns Safety cable DMX input DMX output attachment point Power in socket Power out socket All dimensions are in millimeters Safety information important Every person involved with the installation operation and maintenance of this device has to be qualified and follow the instructions of this manual
5. V Do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain DMX protocol LM 2012 has two Channel modes including 9 Channels Mode and 4 Channels Mode The default mode is 9 channels mode If you want to alter it enter DMX menu 9 Channels Mode strobe 000 019 shutter open 020 064 strobel fast to slow 065 069 shutter open 070 084 strobe2 opening pulse fast to slow 085 089 shutter open 090 104 strobe3 closing pulse fast to slow 105 109 shutter open 110 124 strobe4 random strobe fast to slow 125 129 shutter open 130 144 strobe5 random opening pulse fast to slow 145 149 shutter open 150 164 165 169 170 184 185 189 190 204 205 255 strobe6 random closing pulse fast to slow shutter open strobe7 burst pulse fast to slow shutter open strobe8 random burst pulse fast to slow shutter open CH2 Gobal dimmer CH3 Pan 000 255 0 540 0 630 the maximum angle base in the setting in menu Tilt 000 255 o RS 240 n 000 255 Tilt TA 000 009 010 014 015 039 040 044 045 049 050 054 055 059 060 064 065 069 070 074 075 109 110 114 Fixture control settings No function Reset hold for 8s No function Normal motor speed Maximum motor speed Minimum motor speed No function Max cooling fan speed No function Cooling fan speed trermostatically regulated No function Fast dimmer 115 119 No function 120 124 Smooth dimer 125 24
6. ter Mode Alone Mode LTC Switch FTC Switch Mask Switch ON Switch OFF TC Switch Temp LTC Temp Cap UTC Temp Set FScan Setting FReverse Pan Reverse Pan ON LReverse Pan OFF FReverse Tilt FReverse Tilt ON Reverse Tilt OFF FPan Degree Pan Degree 630 Reset the machine Do not reset the machine default Restore factory settings Do not restor factory settiings default default Temperature control it will reduce the output afeter over temperature Enable the switch default Disable the switch password protected Capture the current temperature Set the value of the TC switch default default Set the max angle rage of the Pan Pan Degree 540 Scan BlackOut FScanBlackOut ON EScanBlackOut OFF EFeed Back Feed Back ON Feed Back OFF Dimmer Curve Square Law Finv Square Law ES Vurve Dimmer Speed Dimmer Smooth Dimmer Fast FDmx Reset FEnabled Disabled Fan Regulated Full Information HTime tt mm ss FDate mm dd yy LUse Time hour minute default Black out while the motor runs default Enable pan tilt position feedback default Disable the feedback default default Enable reset via DMX default Disable reset via DMX Fan speed Thermostatically regulated default Max cooling fan speed 2 DMX menu DMX Menu
7. ttachment such as a safety cable Power connection Installing a Neutrik connector on a power cable 20mm Housing Insert Chuck Bushing Put bushing and chuck onto thecable Prepare cable as shown above The power cable must is a three conductor 2 5mm cable e Insert the wire into the terminals and fasten the clamping device by a flat screw driver Push insert and chuck into housing pay attention to the guiding keyway Fasten bushing the color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts about proper installation consult a qualified electrician Wire color Conductor Symbol Brown Live Blue Neutral IHi Z E Yellow green ground Handling Engagement Relaying power to other devices The lightings can be linked in a chain by power cables which installed a blue and a light gray connectors on the two ends the light gray connector connects to the power out socket of the first lighting and the blue connector connects to the power in socket of the subsequent lighting and so on r in ee ee ee l 1 IN a i is 5 igh ti ti l E Lighting i NAC3FCA l l DEPEN nk ad K k a The power cable must is a three conductor 2 5mm cable When the voltage is 110V Do not connect more than 10 lightings in total to AC mains power in one interconnected daisy chain When the voltage is 220