Home

BRK 9120B Spec Sheet

image

Contents

1. smoke DRIK ALARM eries with 9V Battery Backup 9120B Description The BRK Brands Inc Model Numbers 9120 and 9120B are wire in 120V AC 60Hz single and or multiple station smoke alarms specifically designed for residential Model 9120B only and institutional applications including sleeping rooms of hospitals hotels motels dormitories and other multi family dwellings as defined in standard NFPA 101 DUAL IONIZATION Models 9120 and 91208 comply with UL217 CSFM NFPA 72 HUD FHA and other aati agencies that model their codes after the above agencies They meet building Dual lonization Sensing chamber codes where AC and AC DC with Silence smoke alarms are required The alarms Generally more effective at detecting are interconnectable with up to 18 devices of which 12 can be smoke alarms hig articles sharin ta flaming The BRK 9120 Series alarms feature a dual ionization smoke sensing chamber Ir s oOurces May Include paper or screened for insect protection an 85dB horn 9V battery back up all versions kitchen grease except model 9120 and a silence feature The Smart Technology system is designed to reduce nuisance alarms Latching Alarm Indication remembers which unit initiated an alarm When interconnected in a series the unit that LATCHING ALARM triggered the alarm rapidly flashes its red LED indicator After the alarm condition subsides the initiating unit will store in memory or latch the in
2. 51300 7 9120B 0 29054 51301 4 9120AB 0 29054 51302 1 9120LB 0 29054 51303 8 14 43 L x 6 19 W x 12 63 H 12 9120 9120B 9120AB 9120LB 18 9120B GFD 48 9120B 48P 9120B 48B 7 0 Ibs 9120 7 9 Ibs 9120B 12 8 Ibs 9120B GFD 25 0 Ibs 9120B 48P 9120B 48B 0 653 ft3 9120 9120B 9120AB 9120LB 1 20 ft3 9120B GFD 2 36 ft3 9120B 48P 9120B 48B 9120 100 29054 51300 4 9120B 100 29054 51301 1 9120AB 100 29054 51302 8 9120LB 100 29054 51303 5 19 9120 9120B 9120AB 9120LB 21 9120B GFD 9120B 48P 9120B 48B 6 3 9120 9120B 9120AB 9120LB 2 9120B GFD 3 9120B 48P 9120B 48B 57 9120 9120B 9120AB 9120LB 42 9120B GFD 18 9120B 48P 9120B 48B 684 9120 9120B 9120AB 9120LB 756 9120B GFD 864 9120B 48P 9120B 48B 42 2 ft3 9120 9120B 9120AB 9120LB 59 8 ft3 9120B GFD 43 4 ft3 9120B 48P 9120B 48B 393 Ibs 9120 439 Ibs 9120B 9120AB 9120LB 601 Ibs 9120B GFD 479 Ibs 9120B 48P 649 Ibs 9120B 48B 2009 BRK Brands Inc a Jarden Corporation Company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust ae is a registered trademark of BRK Brands Inc
3. AC Alarm with silence and battery backup ai 9120AB Same as 9120B but with alkaline battery 9120LB Same as 91208 but with lithium battery 9120B 48P 48 pack of Boxed 9120B 9120B 48B 48 pack of Bulk 9120B 9120B GFD 18 count Gravity Feed Display 91206CP Contractor Bulk 6 pack of 9120 Alarm 9120B6CP Contractor Bulk 6 pack of 9120B Alarm D lic IONIZATION Standard RN 9120 Series MOUNTING TOP VIEW SIDE VIEW BRACKET f 5 6 i 20 The smoke alarm shall be a BRK Model 9120B battery backup or 9120 no battery backup and shall provide at a minimum the following features and functions 1 2 3 A lonization smoke sensing chamber The unit shall be capable of self restoring Fully screened sensing chamber to resist entry of small insects thereby reducing the probability of unwanted alarms Powered by 120V AC 60Hz and have a monitored 9V battery backup model 9120B only and a solid state piezo horn rated at 85dB at 10 ft Avisual green LED power on indicator to confirm unit is receiving power or is in alarm A full function test button should check all alarm functions by simulating a smoke condition causing the unit to alarm Silence feature Temporarily silence unwanted nuisance alarms Two Locking features tamper resistant locking pins that lock battery drawer and or alarm to mounting bracket The unit shall be capable of operating b
4. Ceiling or Wall Power Connector Wire Nut 8 Hot Wire Black 7 Interconnect Wire Orange Alarm Dimensions Weight Operating Voltage Operating Current Temperature Range Humidity Range Audio Alarm Test Silence Alarm Reset Interconnections Smoke Sensor Indicator Lights Sounds AC Power DC Power Local Alarm Remote Alarm Latching Alarm Listing 5 6 dia x 2 0 H 6 5 oz 9120 7 8 oz 9120B 120V AC 60Hz w 9V battery backup 9120B only 04 amps standby alarm 40 F 4 C to 100 F 38 C 10 to 90 relative humidity RH 85dB at 10 feet Electronically simulates smoke condition causing the unit to alarm Press and hold test silence button Automatic when smoke clears Up to 18 units of First Alert or BRK Smoke CO and Heat Alarms Maximum of 12 smoke alarms See user s manual for details Dual chamber ionization Constant Green LED Intermittent Red LED 9120B only Red LED flashes rapidly Red LED out Green LED flashes 2 sec on 2 sec off after local alarm Listed to UL217 Standard Individual Carton Dimensions Weight Cube UPC Master Carton Dimensions Master Pack Weight Cube I20f5 Pallet Information Cases per Layer Number of Layers Cases per Pallet Units per Pallet Cube Weight THE PROFESSIONAL STANDARD brkelectronics com 5 69 L x 2 25 W x 5 59 H 0 53 Ibs 9120 61 Ibs 9120B 0 041 ft3 9120 0 29054
5. etween 40 F 4 C and 100 F 38 C and relative humidity between 10 and 90 The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms 12 of which can be smoke alarms The unit shall at a minimum meet the requirements of UL217 CSFM NFPA 72 NFPA 101 ICC Installation of this smoke alarm must conform to all local electrical codes and Article 760 of the National Electrical Code NFPA 70 and NFPA 72 Interconnected units must meet the following requirements Total length of wire interconnecting units should be less than 1000 feet be 18 gauge or larger and be rated at least 300V It is recommended that all units be on the same fuse or circuit breaker If local codes do not permit be sure the neutral wire is common to both phases THE PARTS OF THIS SMOKE ALARM Mounting bracket Mounting Slots Locking Pins Hot Black AC Wire Nuetral White AC Wire Interconnect Orange Wire Battery Drawer Latch Battery Drawer Install 9V battery here Quick Connect Plug o N o o ee NS ara J t e HA nT A Unswitched 120VAC 60 Hz source B To additional units Maximum 18 total Maximum 12 Smoke Alarms 5 Junction Box 6 Neutral Wire White Smoke Alarm
6. formation and INDICATOR begin to flash the green LED indicator 2 seconds on 2 seconds off The Perfect i rT Mount system features a gasketless base and a mounting bracket that keeps the Remembers which unit initiated an alarm alarm secure over a wide rotation range to allow for true alignment This will allow fine tuning on the positioning to compensate for out of aligned wall studs and to keep the wording level when wall mounting A Single button test silence button SINGLE BUTTON eliminates confusion Depending on what mode the alarm is in pushing the button will test silence re test the alarm when in silence and clear the latching feature TEST VA SILENCE scant Merete pele can a pA a ik ee to a ee or wall via the side load battery compartment Other Contractor Preferred features silences and tests alarm with a single include a dust cover to keep alarm clean during construction keyhole slots in the button mounting bracket eliminate the need to remove the electrical box screws for installation Two locking features are provided to prevent battery theft and or theft of the unit Connection to AC TWO LOCKING power is made with a Quick Connect wiring FEATURES harness Installation is a SD i z quick easy and cost E S Pins are provided to lock battery drawer effective r4 N and or alarm to base Perfect for apartment dormitory or hotel applications Available in the following versions 9120 AC Alarm with silence Ei 9120B

Download Pdf Manuals

image

Related Search

Related Contents

Grundig 28 VLE 5401 WG 28" HD-ready White    Samsung MS83HCE-S User Manual  カタログをダウンロード  Lindy 42883 Network Card User Manual  

Copyright © All rights reserved.
Failed to retrieve file