Home
User Manual Haier Solar Water Heater
Contents
1. package 0040503720
2. Please read through the manual before use Please keep the manual for future reference Haier User Manual Haier Solar Water Heater Models GV110RNMB GV150REMB GV200REMB GV270REMB Model without electric auxiliary heating function Table of Contents Safety cautions s s 1 Procucmealllese EEEE 2 Technical parameters 2 Installation instructions gt 2 6 Operation instructions 6 Troubleshooting 7 Packin glee a a a 7 Safety cautions please read the cautions before use Description of symbols Behaviors that Directions that Directions that Prohibit are Prohibited Warming Must be followed Caution Must be noted Warning Improper operation of the following may lead to personal injury or even death Do not touch glass vacuum tube Personnel other than professional pipes and valves for supplying O maintenance staff are prohibited Prohibit Aig a ig use to avoid Prohibit from repairing maintenance eel dismantling or altering the water Please feel the water temperature heater without authorization Warning oy hand before use to make sure of proper water temperature while in use Caution Improper operation of the following may lead to personal injury or even death or property loss Please do not use the hot water in the Q The glass vacuum tube shall not be Prohibit heater for drinking or similar purposes exposed for a long period without water Warming _ inside after ins
3. GV110RNMB GV150REMB GV200REMB GV270REMB Specifications of the 058mm X 1800mm glass vacuum tubes all glass vacuum tube solar heat collector Horizontal 45 Numb 1 58m 2 07m 2 90m 4 03m Usable water 110L 150L 200L 270L Total water volume 141L 195L 203L 342L Electric auxiliary heating 1500W 220V 1650W 230V Note The deviation of the aperture area is lt 3 the deviation of the capacity is 5 the permitted error limit of other parameters is 10 er of the E Installation instructions 1 The water heater shall be installed within the Selection of installation location lightening protected area of a building in locations prone to lightning strikes 2 The orientation of the water heater to be installed 10 south by east and 15 south by west in the H Northern Hemisphere 10 north by west and 15 north by east in the of W Southern Hemisphere O L 3 There must be no shielding object in front of the installation location of the water heater If an object exists the space between the heater and the j objective shall be more than L z se tg 00 9 Q wherein H height of the shielding objective a local latitude Installation instructions Exterior and installation dimensions of horizontal water heater Installation dimensions unit mm unit mm ees mL GV110RNMB 1160 1725 1000 1490 GV150REMB 1600 1725 1320 1490 GV200REMB 1957 1725 1775 1490 GV270REMB 1725 2435 1490 Note The permitted error limit
4. state used normally Suggestions The water heater is non pressurized gravity fed water heater relying on the height difference of the water tank and point of use to supply hot water with the outgoing water pressure in direct proportion to the height An additional pressurizer may be required Please clean the glass vacuum tubes before the winter comes Keep their surface clean to maintain heat collection efficiency In the area where it s very cold in the winter we recommend you select our optional solar energy heater controller with anti freeze function Product features Technical parameters Installation instructions E Product features 1 Inner cylinder made of SUS304 stainless steel The inner cylinder of the water tank adopts sanitary SUS304 stainless steel featuring strong corrosive resistance and durability 2 High efficiency amp energy saving thermal insulation With integrated polyurethane foam insulation for solar water heaters realize good heat preservation and minimize heat loss 3 Aluminium Zinc coated outer shell of water tank Aluminium Zinc coated sheet boasting outstanding corrosion resistance oxidation resistance and weatherability is the first choice for outdoor protective materials 4 Tower type frame The tower type frame made of carbon steel by means of spray processing has the advantages of a stable structure attractive appearance and corrosion resistance H Technical parameters Model o
5. e with e asolderless connection WAY m S ensor pipe 2 Overflow pipe and water inlet pipe both use M Do not apoy T Ns ot X axial direction solderless structure To install use a wrench to secure the water tank pipe head In ordertoavoid damaging the seals do not rotate water tank pipe head and do not apply force along the axial direction of the fit AX x of the pipe 3 When installing the water inlet and outlet pipe first use a wrench to secure the water tankpipe head During installation use a wrench then unscrew the plastic cap and use inner ratchet to fasten the tank pipe end teeth to directly connect tothe PEX pipe Before installation check that the gasket ring of the water inlet and outlet pipe is intact Notice 1 Rip off the protection film after installationto avoid the destroy of the tank and please do not use the sharp tool 2 Leave nuts loose since some adjustment may be necessary after fitting tubes 3 When assembling the water tank keep the center line of the vacuum tube connecting holes parallel with the diagonal pillar of bracket 4 The inlet and outlet of the water tank can be also used as the drain Installation instructions Installation of vacuum tubes 1 Keep the tubes out of the sunlight before assembling the tubes to avoid being burned 2 Place the air seal ring around the vacuum tubes Figure A 3 Insert the tubes into the seal ring with even pressure and a twistin
6. edded sleeves wherein the former three types are commonly used Before installation the installation staff will consult the entry form and installation location of the pipe in a comprehensive way and in consideration of your convenience A slope in the through wall ve must be ensured during pipeline layout and sealing shall be guaranteed to prevent Outdoor ANA NANANNNNNN EET controller 000000 IM bulyeay 011 09 4 JIM JOSUBS Non return valve the entry of rain or odors Keep the smoothness of the air pipe to Mixing valve L BES A Tanwar prevent the blockage of impurities which hot Wales may lead to collapse and deformation of the water tank under suction when using Mixing valve cold water l water The diagram subjectto GV150REMB isfor Do not install a valve in the overflow reference only pipeline to ensure that the flood signal can be sent out rapidly and accurately 5 To avoid the return of water in the tank a non return valve shall be installed at the joint of the water upward downward pipes and the tap water 6 The installation project should be confirmed by our professional service personnel when installing several sets of the series of the products Connection of water supply pipes when the solar water heater coexists with other water heaters To solar water tank mma ZN Warning Please install another non return valve on the cold and hot water pipes respectivel
7. g motion The resultant force direction shall be consistent with the axial direction of the vacuum tubes 4 Place the tubes into the tail support of the frame Figure B and then fix the tube onto the tail base Figure C 5 Insert the tube into the seal ring at the depth of around 1cm push the air seal ring to the water tank hole for sealing Figure D 6 While assembling install one tube on each end of the heater tank respectively first so that the heater tank and frame are positioned as a whole Seal ring Tail support Vacuum tube Air seal ring Tail base Vacuum tube Tail base Air seal ring Tail Support Sealing location Notice 1 Check whether the seal rings in tank holes are sufficiently installed and whether the sealing location is clean and free from foreign matters and damage 2 Place the bevel of the air seal ring downwards and then put it onto the open end of the tube with a clearance of around 10cm from pipe end Make the pipe end wet before insertion for easy assembly amp Installation of electric heater and Operation instructions Please refer to the Operation Manual of Solar water heater controller Model HR QBJ1 KSD in the controller package Installation instructions 1 2 There are five ways to connect the water 4 Any alteration to the structure of the solar water heater may cause problems in use eH pipe to the room flue vent hole through hole in the wall pipe well for solar pipes and emb
8. of the parameters above is 10 Electric heating Tanksupport Scissors truss support Front post Back post Scissors truss support Cross member The diagram subjectto GV150REMB Foot s for reference only Support foot Installation instructions Frame assembly Please see the related paper in the frame package for the diagram of the frame and packing list lt gt Frame fastness 1 For horizontal water heaters it is recommended to fix the feet of the heater onto the foot foundation with embedded iron parts or make a concrete brick with expansion bolts and then fix the feet of the heater to the expansion bolts 2 Adjust the height of the frame by the hard waterproof cushion to keep the horizontal tank and each foot evenly weighted Notice 1 Make sure that the feet all closely contact the supporting floor without foot suspension to avoid damage of the product due to frame deformation 2 Please use the steel wire to firmly fasten the tank and frame if in a location where typhoons frequently occur 3 The water heater shall be stably and firmly installed to avoid severe damage or accident due to harsh weather conditions D Tank installation 1 Unpacking the tank rip off the protection film Uninstall the nut and cushion 2 Place tank onto tank bracket cradle inserting protruding bolts into holes fasten with nuts Installation of Solderless Pipe Head 1 Pipe fitting is connected to water pip
9. tallation to avoid the To guarantee effectiveness do not feed shortening of the service life If it cannot Warning Water to the heater several times within be used immediately it shall be covered one day in case of insufficient sunlight exposure Q The water heater is equipped with a Waning special venting pipe and overflow pipe The glass vacuum tubes can withstand To ensure normal operation never refit Waring low temperature of 70 C when they or plug their outlets Otherwise the water are not filled with water When the tank will shrink auxiliary heating device is not to be used on continuous cloudy days in winter or Water shall be fed in early moming or at when the tubes are covered by snow be warming night when the sunlight is insufficient The sure to keep the water tank full of water water feeding after sunlight exposure of and replace the cold water in the tank the glass vacuum tube will cause an frequently every 2 days Otherwise the explosion of the pipe water retained in the tank will cause the vacuum tubes to break A Water shall be fed in early morning or at Waring night when the sunlight is insufficient The When the heater with auxiliary electric temperature of the hot water delivered heating function is used ensure the may not satisfy your requirement If there S auxiliary electric heater and electric is no electric heating as an auxiliary Prohibit heating accompanying strap are in OFF energy source it may be unable to be
10. unesy Oljoe S JIM JOSU Solenoid valve wire ask Mixing valve cold water The diagram subjectto GV150REMB is for E Troubleshooting reference only Phenomena Possible causes Solutions The tank is empty Add water according to the tank The pipeline or the connector falls off or is blocked Maintain the pipeline or remove the blockage No water supply In the winter water in the feeding outgoing pipe Start the accompanying heating strap may become frozen or wait for natural ice out The vacuum tube is damaged Replace the tube Tap water supply stopped or low water pressure Wait for normal water supp No water from Pipeline or connector may become broken Repair or replace the pipeline or connector the overflow In the winter water in the feeding outgoing pipe Start the accompanying heating strap pipe May become frozen or wait for natural ice out In bad weather or winter when the sun is relatively low the sunlight time is short atmosphere quality is The temperature poor and sunshine radiation energy is insufficient The valve for water supply is loose or damaged Tighten orreplace the valve The vacuum tube cannot effectively collect heat Remove the blockage or change the due to a blockage in front of it location for installatio Dust on the tube Clean the tubesurface Use auxiliary electric heating as an option I Packing list Quantity Main parts GV110RNMEIGV150REMB GV200REMB GV270REMB Water tank
11. y if the solar heater coexists with other water heaters so as to avoid L accidents caused by water returned to Nonteum the solar water tank through hot water Non return valve m saci pipe due to high pressure in the tanks UUJUUUU UU UU UU UU UU UU UU UU UU UU UU han se woke ANNANANAANNAANANANAAANANANAAAAANANANA E Operation instructions Notice Improper operation of the water heater may lead to serious burns When using the heater do not make the water outlet of the nozzle aim at the body mix the cold and hot water before use Operation instructions Troubleshootinge Packing list amp Operations 1 Before using water the manual valve mixing valve hot water and mixing valve cold water should be closed 2 To fill water use automatic function on the controller or open the manual valve 3 When using manual valve when water flows from the overflow pipe it indicates the water tank is full Close the manual valve to finish filling water 4 To use water open the mixing valve hot water and the water comes from the shower nozzle If the water is too hot open the mixing value cold water to adjust the water temperature E Solenoid valve oa aise 5 After use of water make sure the manual hot water YF valve and mixing valves are closed e Over flow port gp Outdoor UWUVUVOUVOUVUUUUNUU raravavararavavavovavatavavavavadl Indoor controller Accompanying heating D