Home
V520-LGP6125 Handheld CCD Scanner User Manual
Contents
1. Part Ill Bar Code Menu Functions A Programming the Scanner 7 B Symbology Selections 8 Enabling only a single symbology 8 Enabling an additional symbology 10 Setting options for UPC ASE 13 Setting options for EAN 13 and 8 15 Code 39 Settings lt lt lt 17 Codabar Settings w wwwwwmwmmmaa 19 20f5 SettiNngs www wwmmmmmema 22 MSI Plessey Setting lt ww w w 24 Code 128 Setting w ww wwmwe 25 JATA SettiNgs iss KAA EES Se ge 26 C Universal Selections 28 Case Conversion ee ee Re 28 Prefix OPON Sa 29 Suffix Options ees ee ke Re 31 Direct Input Keyboard Keys s 33 Direct Input Characters lt lt lt lt 36 Direct Input Control Characters 44 Read Mode Settings lt lt 47 Trigger Settings wwww wwmamemamaza 48 Beeper OptiONS seke ke ee 52 Good Read Indicator LED 54 Part 1 CCD Scan V520 LGP Handheld CCD Scanner Part CCD Scanning V500 General Information The V520 LGP6125 Series CCD Scanners utilize state of the art imaging technology similar to that found in digital cameras facsimile machines and video camcorders
2. Leading O data 11 digits check digit add on 2 or 5 Options for UPC A e Disable transmission of the leading zero e Disable transmission of the check digit Options for UPC E The UPC E symbology is a fixed length symbology encoding 6 data digits a check digits and non printable start stop characters Supported characters include numeric digits 0 to 9 An optional leading zero can be transmitted which together with the data and the check digit forms an 8 digit field providing a com patibility with the EAN 8 format String Format Leading O data 6 digits check digit UPC E add on 2 add on 5 The UPC E symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String Format Leading 0 data 6 digits check digit add on 2 or 5 Options for UPC E e Enable transmission of the leading zero e Disable transmission of the check digit e Transmit UPC E as UPC A 14 Part III Bar Code Menu Functions EAN 13 and EAN 8 Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu 6K EAN 13 transmit CD EAN 13 oa AA transmit CD 6l EAN 8 transmit CD EAN 8 ala ME transmit CD IB Disable ISBN translation IA Enable ISBN translation IK Enable ISBN if possible HN Disable ISSN translation HO Enable ISSN translation 4V Enable ISSN if possible 15 Part III
3. V520 LGP Handheld CCD Scanner ZZ Start End Program Menu F f G H I J K L M N O P Q R S Continued on next page Part III Bar Code Menu Functions Direct Input Characters cont V520 LGP Handheld CCD Scanner ZZ Start End Program Menu T t U V W X Y Z 43 Part III Bar Code Menu Functions Direct Input Control Characters 44 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu 9G NUL 1A AA SOH 1B B STX 1C C ETX 1D D EOT 1E E ENQ 1F F ACK 1G G BEL 1H AH BS 1 I HT 1J AJ LF 1K AK VT 1L AL FF 1M AM CR Continued on next page Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Direct Input Control Characters cont ar maal N so NN 10 sosh NDN P aa Qj saon NN R oca AAA S soca NN T seoa AA U wao S AAA Wi sew INN W we NN X scan AA Y xew NN Z ma 9A meso NN Continued on next page 45 Part III Bar Code Menu Functions Direct Input Control Characters cont V520 LGP Handheld CCD Scanner Direct Input Code
4. V520 LGP6125 Handheld CCD Scanner USER MANUAL OMRON V520 LGP6125 Handheld CCD Scanner User Manual OMRON 2003 All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of OMRON No patent liability is assumed with respect to the use of the information contained herein Moreover because OMRON is con stantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication Table of Contents PART CCD Scanning General InformatiON sees neern UnpacKing ses ee EES He Ee eee Factory Technical Support lt PART II Installation and Setup A Installation RS 232C Interface Reset all Defaults RS 232C Communication Parameters Baud Aali ee ee eed Data Bits Stop Bits Parity B V520 LGP6125 Installation Omron PLC or Touchscreen Reset all Defaults
5. Return Merchandise Authorization number prior to returning the product The Customer Service Dept may be reached at 847 843 7900 Note Returned merchandise will not be accepted without a RMA number indicated clearly on the outside of the carton Part II Installation and Setup VS20 LGP Handheld CCD Scanner A Installation RS 232C Interface The RS 232C scanner cable is terminated in with a DB9 female connector An external power supply 5V DC is necessary only if the port used does not supply 5 VDC on pin 9 Installation is as follows 1 Plug the scanner into an RS 232C serial port such as COM1 of the host PC External power is required insert external power plug into the jack on the RS 232C connector 2 Connect the power supply into an electrical outlet 110 V AC 3 Turn on the power to the host computer Make sure the communication parameters of the computer match those of the scanner The default communications settings are 9600 baud 8 data bits 1 stop bit no parity no handshaking 4 Be sure the PC is in a program such as Hyperterminal that will accept input from the serial port Reset All Defaults RS 232C Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers In most applications the scanner will work right out of the box without any need for additional pro gramming At any time you can return the scanner to the factory d
6. ASCII Code 39 In this mode the decoded data characters are translated to full ASCII Code 39 Full ASCII Code 39 if possible In this mode the decoded data characters are translated to full ASCII code 39 Invalid combinations are not translated and are transmitted as is Concatenation If a Code 39 bar code contains a leading space the data is stored into the reader s buffer without the leading space As soon as a Code 39 bar code is read without a leading space the data is appended to the reader s buffer and the entire buffer is transmitted and cleared for new data 18 Part III Bar Code Menu Functions Codabar Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu FO Do not transmit start stop F1 Transmit start stop as ABCD TN E F2 Transmit start stop as abcd tn e Transmit start AE aa ABCD Transmit start 4 seooae eed IMANTNI abcd H3 Enable Codabar ABC and CX H4 Enable only ABC code H5 Enable only CX code oa Tan H7 Do not check CD oa aa H9 Do not transmit CD Continued on next page 19 Part III Bar Code Menu Functions Codabar Settings cont V520 LGP Handheld CCD Scanner ZZ Start End Program Menu Enable Codabar UR AE EE only HB Min data 3 chars HC Min data 1 char HD Enable space insertion HE Disable space 5 insertion HF Min data Ee 5 chars HH Enable interchar 5 gap c
7. and negative bar codes Positive and Negative Bar Codes Usually bar codes are printed black on white but sometimes white on black These labels are called positive and negative respectively 51 Part III Bar Code Menu Functions Buzzer Settings 52 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu W8 Enable software buzzer Wo owes TM TTT W1 Single tone buzzer wa won ow cer TM NTT W3 Low high buzzer W7 Buzzer duration 50 msec W4 Buzzer duration 100 msec W5 Buzzer duration 200 msec W6 Buzzer duration 400 msec TO Buzzer volume maximum T1 Buzzer volume loud T2 Buzzer volume normal T3 Buzzer volume minimum VY Buzzer before transmission sO Continued on next page Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Buzzer Settings cont ZZ Start End Program Menu VZ Buzzer after transmission GD Disable startup buzzer GC Enable startup buzzer Buzzer Settings These options determine the buzzer type tone duration and loudness By default the buzzer is disabled for Linker type readers Buzzer Type The buzzer may be disabled or enabled as either a hardware of software buzzer Not all readers support both a hardware and software buzzer Buzzer Tone If a software buzzer is used the buzzer tone may be selected Buzzer Duration and Volume If a software buzzer is used a buzzer
8. duration of 50 100 200 or 400 m sec may be selected Volume may also be adjusted Buzzer Before Transmission The good read buzzer will be activated after decoding the bar code but before transmission During transmission the buzzer sequence will be completed Buzzer After Transmission The good read buzzer will be activated after transmission Enable Startup Buzzer When this option is selected the reader will generate a single good read buzzer to indicate the reader is ready after the reader is supplied with power Disable Startup Buzzer When this option is selected the reader will not sound the buzzer after the reader is supplied with power 53 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Good Read LED ZZ Start End Program Menu MEI IN T5 Indicator duration 0 2 sec T6 Indicator duration 0 4 sec T7 Indicator duration 0 8 sec Diagnostics ZZ Start End Program Menu Z1 Transmit software version SABA TUTTI ZA Transmit ASCII printable string YV Transmit ASCII control string somoro UU DID TI Error msg no decode 54 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner 55 Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual Cat No Q05BAZ1 Revision code The following table outlines the changes made to
9. the manual during each revision Page numbers refer to the previous version 1 March 2003 Original production OMRON OMRON ELECTRONICS LLC 1 Commerce Drive Schaumburg IL 60173 847 843 7900 For US technical support or other inquiries 800 556 6766 OMRON CANADA INC 885 Milner Avenue Toronto Ontario MIB 5V8 416 286 6465 OMRON ON LINE Global http www omron com USA http www omron com oei Canada http www omron ca UNITED STATES To locate a Regional Sales Office local Distributor or to obtain product information call 847 843 7900 CANADA REGIONAL SALES OFFICES Ontario Toronto 416 286 6465 Kitchener 519 896 1144 Kingston 613 376 3968 Quebec Montreal 514 636 6676 British Columbia Vancouver 604 522 8855 Alberta Edmonton 403 440 0818 Calgary 403 257 3095 Sao Paulo 55 1 1 5564 6488 Cono Sur 54 1 14 787 1 129 Florida 954 227 2121 Ciudad Juarez 656 623 7083 Mexico D F 555 534 1195 Monterrey N L 818 377 4281 Q05BAZ1 3 03 2003 OMRON ELECTRONICS LLC Specifications subject to change without notice Printed in the U S A
10. Bar Code Menu Functions V520 LGP Handheld CCD Scanner EAN 13 and EAN 8 Settings cont EAN 13 is a fixed length symbology encoding 12 data digits a check digit and non printable start stop charac ters Supported characters are numeric digits 0 to 9 The data may be translated into ISBN or ISSN format String Format data 12 digits check digit EAN 13 add on 2 add on 5 The EAN 13 symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String Format data 12 digits check digit add on2or5 EAN 8 is a fixed length symbology encoding 7 data digits a check digit and non printable start stop characters Supported characters are numeric digits 0 to 9 String Format data 7 digits check digit EAN 8 add on 2 add on 5 The EAN 8 symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String Format data 7 digits check digit add on2or5 Options for EAN e Disable transmission of the check digit e Enable ISBN or ISSN translation Enable ISBN or ISSN translation If this option is enabled an EAN 13 label is verified for the correct format and transmitted as a 10 digit ISBN number or 8 digit ISSN number 16 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Code 39 Settings ZZ Start End Program Menu Co ceco TNI C1 Do
11. LGP Handheld CCD Scanner ZZ Start End Program Menu 50 SP 6A 6B 6C 6D 6E 6F 6G 7A 7B 7C 7D 7E Continued on next page 37 Part III Bar Code Menu Functions Direct Input Characters cont 38 V520 LGP Handheld CCD Scanner ak AN Program Menu di RD MEEN je ED MEEN 9W Continued on next page Part III Bar Code Menu Functions Direct Input Characters cont V520 LGP Handheld CCD Scanner ZZ Start End Program Menu QO 0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 OA OB OG Continued on next page 39 Part III Bar Code Menu Functions Direct Input Characters cont 40 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu OD D OE OF 0G OH ol OJ OK OL OM ON 00 OP 0Q Continued on next page Part III Bar Code Menu Functions Direct Input Characters cont V520 LGP Handheld CCD Scanner ZZ Start End Program Menu OR R 0S OT OU OV OW OX OY 0Z A B C D E Continued on next page 41 Part III Bar Code Menu Functions Direct Input Characters cont 42
12. ST SP Disables the transmission of the start and stop characters of a bar code 12 Part III Bar Code Menu Functions UPC Settings V520 LGP Handheld CCD Scanner Note Options for UPC A and UPC E bar codes Abbreviations Xmit transmit CD Check digit CC Country code ZZ Start End Program Menu E2 UPC A as EAN13 w CD 13 digits E3 UPC A w CD 12 digits E4 UPC A w CD 12 digits E5 UPC A w o CD 11 digits E6 UPC E w CC amp CD 8 digits E7 UPC E w o CC w CD 7 digits E8 UPC E w CC w o CD 7 digits E9 UPC E w o CC amp CD 6 digits 6P Xmit UPC E as UPC A w CD 8 digits 6Q Do not xmit UPC E as UPC A w o CD 7 digits 13 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner UPC Settings cont Options for UPC A The UPC A symbology is a fixed length symbology encoding 11 data digits a check digit and non printable start stop characters Supported characters are numeric digits 1 to 9 An optional leading zero can be transmitted which together with the data and the check digit forms a 13 digit field providing compatibility with the EAN 13 format String Format Leading 0 data 11 digits check digit UPC A add on 2 add on 5 The UPC A symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String Format
13. The scanner images the bar code label then con verts the digital signals into data the host computer can understand By capturing the bar code image all at once the scanner provides fast highly accurate reading Miniature surface mount electronics make up the CCD scanner s solid state construction CCD scanners have no moving mechanical parts and provide years of trouble free operation This manual contains information on setting up the scanner as well as programming various parameters of the scanner The V520 LGP6125 scanner is available in several different interface configurations e RS 232C Serial Interface e Omron PLC Touchscreen P There is a specific section of this manual for installing each type of interface Be sure you are using the section of the manual that pertains to the interface you are using Unpacking Remove the scanner from its packaging and inspect it for damage If the scanner was damaged in transit call the sales representative from whom you purchased it If you purchased it directly from Omron call Omron Cus tomer Service Dept at 847 843 7900 Factory Technical Support If you have any questions or need assistance with programming your scanner call Omron Technical Support at 800 556 6766 Please have the unit model number and several bar code labels readily at hand The model number is located near the connector end of the cable If the scanner must be returned please contact Omron to obtain an RMA
14. arameter at a time can be changed Until some proficiency at programming is achieved it is highly recommended that users change only one parameter at a time and test the change before proceeding to program any additional changes It is also recommended that users keep a record of the changes made to the scanner What If Make A Mistake Scanning the Reset All Defaults bar code for your type of interface will return the scanner to all factory default settings including any changes made during previous programming sessions Note OO A pointing finger indicates scanner default settings throughout the fol lowing menus Part III Bar Code Menu Functions B Symbology Selection V520 LGP Handheld CCD Scanner ZZ Start End Program Menu AO Read all codes A2 Code 39 only A3 Codabar only A4 IATA only A5 Code 93 only A6 Code 128 only A7 MSI Plessey only A9 Telepen only AB Matrix 20f5 only JO All UPC and EAN only J1 UPC only Continued on next page Part III Bar Code Menu Functions Symbology Selection cont V520 LGP Handheld CCD Scanner ZZ Start End Program Menu only only J4 EAN only J5 EAN 2 only only Industrial wa aa only Interleaved J8 2of5 DRR only JD Trioptics only These options do not influence the reading of the menu labels The required bar c
15. ch screen Power will be supplied by the PLC or touch screen If connecting to a touchscreen only port A can be used Reset All Defaults Omron Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers In most applications the scanner will work right out of the box without any need for additional pro gramming At any time you can return the scanner to the factory default settings by scanning the Reset all Defaults programming bar code below Make sure the PLC touch screen port settings match the scanner ZZ Start Program Menu U2 Omron PLC touchscreen ZZ End Program Menu Note Default settings 9600 7 E 2 If changes are needed use the codes in section A PLC Received RXD EE A B Flag C Lo Scanner Trigger wires can be wired to output to externally trigger the scanner A Start register where bar code data is to be stored in PLC If using a touchscreen make sure the scanner is configured for using STK for a start character and ETX for an end character NT NS Screen Bar code data will appear in the active string window on the touchscreen Port A only Scanner Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Part Ill Bar Code Menu Functions A Programming the Scanner This manual contains information that allows you to easily c
16. char Options for Codabar e Enable ABC code concatenation e Enable CD code concatenation Enable check digit check e Disable transmission of the check digit e Disable transmission of start stop e Selection of start stop character translation Selection of minimum number of data characters e Enable library space CLSI insertion Space Insertion This option inserts spaces in position 2 7 and 13 of the data string for use in library sys tems ST SP Translation This option enables the translation and transmission of the start and stop characters Thus if the option ST SP abcd tn e is chosen the start character is converted to lower case e g from A B C or D to a b c or d respectively and the stop character is converted from A B C or D tot n or e respec tively Minimum Data Characters Codabar labels are checked for a minimum of 1 3 or 5 characters as set by the user If the number of characters in the label is shorter than the minimum selected the label will be rejected If the fixed length option is used for Codabar type labels then such labels will additionally be checked for fixed length This option will no longer be supported in future software releases Intercharacter Gap Check This option enables the reading of Codabar labels with a large or irregular gap between characters 21 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner 20f5 Settings ZZ Start E
17. check digit calculation e Selection of the number of check digits to be transmitted Check Digit If the check digit calculation is required then the appropriate calculation method must be selected Do Not Transmit CD The character positions CD1 and CD2 are not transmitted Transmit CD1 The character position CD2 is not transmitted Transmit CD1 and CD2 All characters in the label are transmitted 24 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Code 128 EAN 128 Settings ZZ Start End Program Menu Enable an EMMETT only MO Enable FNC2 concat enation MP Disable FNC2 WA concat enation OF Disable EAN 128 k Enable 06 nies NNNMNN if possible Code 128 is a variable length symbology with a mandatory check digit and non printable start stop characters Supported characters include All 128 ASCII characters 4 non data function characters e 4 code set selection characters e 3 start characters and e 1 stop character The check is calculated as the sum modulo 103 of the start character and the weighted values of the data and special characters String Format data 1 or more characters EAN 128 In this mode the Code 128 data is translated to the EAN 128 format EAN 128 data starts with the FNC1 character and separates 2 data fields with the FNC1 character The first FNC1 character is translated to C1 and the second FNC1 character is tran
18. efault settings by scanning the Reset all Defaults programming bar codes below First scan the Start Program Menu bar code below then scan the Reset all Defaults programming bar code and then the End Program Menu bar ZZ Start Program Menu U2 RS 232C Reset all defaults ZZ End Program Menu i mera Scanner Power supply Part II Installation and Setup VS20 LGP Handheld CCD Scanner RS 232C Communication Parameters Handshaking Protocol Start ZZ Program Menu EDEN PO None IN JI II II HPo4 Frs rs ARBEID Pa ACKINAK IN Il ll ll ZG Xon Xoff IIIi Hl ll ll To Flow Control Time Unlimited 1 Flow Control 100ms 2 Flow Control 200ms 3 Flow Control 400ms Baud Rate K7 12200 MAA LA K6 2600 A r K5 4800 INANA NTIN K4 2400 IA K3 1200 LUUL K2 600 IIT Part II Installation and Setup VS20 LGP Handheld CCD Scanner Data Bits Stop Bits Parity LO 7Daa is IATA LY seta Bis IAA AN L5 1 separ IAA L6 2snp ats IAA d d Even L3 Party MOAT AM NA Odd L4 Party RD Mark lt L2 No Party MUA NI End ZZ program Menu ADD Part II Installation and Setup VS20 LGP Handheld CCD Scanner B Installation Omron PLC or Touchscreen Plug the scanner into the serial connector on your PLC or tou
19. git has a value that can be calcu lated from the other data characters and is usually the last data character in a bar code e Pre editing of the data string such as removing the check digit and or ST SP characters The more common options are described here Check CD Enables the check digit calculation If the calculated check digit does not correspond to the check digit in the bar code then the bar code is ignored The use of a check digit greatly improves the security of a bar code Do Not Check CD Disables the check digit calculation This option is required when the bar codes do not contain a check digit or contain an invalid check digit Transmit CD Enables the transmission of the check digit together with the data characters If the check digit calculation is disabled the reader cannot differentiate between a valid check digit and a data character It will therefore transmit all data characters of the label including what could constitute a check digit Do Not Transmit CD Disables the transmission of the check digit If the check digit calculation is disabled the reader cannot differentiate between a valid check digit and a data character It will therefore transmit all data characters of the label excluding the character that could constitute the check digit for the type of bar code Transmit ST SP Enables the transmission of the start and stop characters of a bar code Do Not Transmit
20. gram Menu RT EN ej w MR EN MO UPC A add on M1 UPC E add on M2 EAN 13 add on M3 EAN 8 add on Mel ceos UA ON BE GET TN Continued on next page 29 Part III Bar Code Menu Functions Prefix Settings cont 30 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu M7 Interleaved 20f5 M8 Code 93 M9 Code 128 NO MSI Plessey N1 UPC A N2 UPC E N3 EAN 13 N4 EAN 8 RY All codes MG Clear all prefixes MZ Preamble Part III Bar Code Menu Functions Suffix Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu GM Matrix 20f5 IATA L9 Telepen N5 MSI Plessey N6 UPC A N7 UPC E N8 EAN 13 N9 EAN 8 OO UPC A add on O1 UPC E add on 02 EAN 13 add on O3 EAN 8 add on 04 Code 39 O5 Codabar Continued on next page 31 Part III Bar Code Menu Functions Suffix Settings cont 32 V520 LGP Handheld CCD Scanner af N Program Menu OS wouswenaos MMMA O7 wevecvea zo MTANI OS cosso EN HET EN PR Clear all suffixes UNAM A AH PS Postamble Da RZ All Codes Part III Bar Code Menu Functions Direct Input Keyboard Keys V520 LGP Handheld CCD Scanner ZZ Start End Program Me
21. hange certain programmable parameters of the scanner The scanner is ready to use no additional programming is required in most situations The scanner has been programmed at the factory with the most common settings These factory default settings are ideal for most situations A specific parameter is set or changed by scanning one or more of the special programming bar codes found on the following pages For each parameter you can choose from a menu of options When you scan the spe cial bar code for a specific menu option the scanner retains the changes you have made even if you discon nect the scanner or turn off the power Step by Step Programming is easy Simply 1 Scan the bar code for Start End Program Menu ZZ The scanner will beep continuously to indicate that it is ready to be programmed When the scanner is in Programming Mode it cannot read normal bar code It can only read the special bar codes found on the following pages 2 Select desired parameter from menu and scan the bar code The scanner will beep once and the green light will flash indicating the desired parameter has been scanned The scanner will continue to beep continu ously while in Programming Mode 3 Scan Start End Program Menu ZZ The scanner will stop beeping indicating that it is back in normal scanning mode The changes made while in Programming Mode are now saved in the scanner s memory When the scanner is in Programming Mode more than one p
22. heck Disable i woro NANT check Codabar Settings Codabar NW7 is a variable length symbology with an optional check digit and printable start stop characters Supported characters include e Numeric digits 0 to 9 e special characters e start stop characters are A B C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters String Format start char data 1 or more chars check digit stop char 20 Continued on next page Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Codabar Settings cont ABC Code The ABC code is an acronym for American Blood Commission The code consists of two bar codes which are decoded in one read cycle The code is concatenated linked in series when the stop character of the first bar code and the start character of the second bar code is a D These two D s are not transmitted String Format start char data 1 chars check digit data 1 chars check digit stop char CX Code The CX Code consists of two are codes which are decoded in one read cycle The code is concat enated when the stop character of the first bar code is a C and the start character of the second bar code is a B The B and C characters are not transmitted String Format start char data 1 chars check digit data 1 chars check digit stop
23. hind the code the reader ignored the code in case it is not a valid add on 47 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Trigger Settings ZZ Start End Program Menu S7 Disable trigger S8 Enable trigger Disable Trigger This is applicable to readers which have a trigger switch When this option is selected the reader will stay ON all the time Multiple Read Reset Time af N Program Menu AM soms MAN Aj oms T MAMANMI ME MA IN EN ME AN MIN EN EE AN eoms EED Multiple Read Reset Time This option can be used in conjunction with multiple read mode It sets the time the reader should be pointed away from the label before it can decode the same label again 48 Part III Bar Code Menu Functions Quiet Zone Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu YN No margin check YO Margin check 1 7 normal YP Margin check 2 7 normal YQ Margin check 3 7 normal YR Margin check 4 7 normal YS Margin check 5 7 normal YT Margin check 6 7 normal YU Margin check normal With these settings the reader can decode bar codes that have smaller start and or end margins than speci fied for the symbology These settings may increase the possibility of partial and ghost reads hence do not use sma
24. ion of the minimum number of data characters e Disable space check for industrial 2of5 e Transmit S Code as Interleaved 20f5 Minimum Data Characters Code 20f5 are checked for a minimum of 1 3 or 5 characters as set by the user If the number of characters in the label is less than the number set the label will be rejected If the fixed length option is used for a Code 20f5 type label then such label will also be checked for fixed length Intercharacter Gap Check This option enables the reading of Industrial 20f5 labels with a large or irregular spacing 23 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner MSI Plessey Settings ZZ Start End Program Menu 4A Do not check CD 4B Check 1 CD Mod 10 AC Check 2 CD s Mod 10 Mod 10 AD Check CD s Mod 10 Mod 11 GN EN ENE AF Transmit CD1 and CD2 4G Do not transmit CD AR Check CD s Mod 11 Mod 10 MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start stop characters Supported characters include numeric digits 0 through 9 The checksum is calculated as the sum modulo 10 or 11 of the data characters The checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and CD1 String Format data 1 to 13 digits CD1 CD2 Options for MSI Plessey e Disable check digit check Selection of the
25. ions which can be made to the format of the transmitted data string Options available are e Case conversion e Transmission of a code identifier e Transmission of the code length e Transmission of a prefix e Transmission of a suffix The prefix and or suffix may include a code identifier and or the code length String Format Case Conversion prefix bar code data suffix Case Conversion The bar code may be converted to either lower or upper case or the case may be exchanged These options may be used if the user of a wedge has a preference to leave for instance the CAPSLOCK ON or if the host required upper case characters only 28 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Setting a Prefix or Suffix A Prefix and Suffix consisting of a maximum 4 direct input entries each may be included in front and at the end of the string respectively The following steps are used to establish a Prefix or Suffix that will be transmitted with the bar code data 1 Scan Start End Program Menu to enter programming mode 2 Scan the bar code representing the desired symbology you wish to add a Prefix or Suffix to 3 Scan the character s that comprise the Prefix or Suffix Up to 4 numbers letters or control characters may be used 4 Scan Start End Program Menu to exit programming mode Prefix Settings ZZ Start End Pro
26. ller margin checks than necessary Replace any bar code labels with ones that have the correct start and end margins if possible 49 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Read Time Settings af AAA Program Menu ON EN MET EN MAN EN EE ON EN AR EN AR EN AN EE ME NE ON EN N EN x 10 WANA Read Time Settings the length of the period that the reader is ON after the trigger switch is pressed or in multiple or continuous read mode after a label has been read Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed Selecting a read time for readers without a trigger switch or when the trigger switch is disabled has no effect 50 Part III Bar Code Menu Functions Redundant Decoding Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu XO wovedundancy TMENIN X1 Two times redundant X2 Three times redundant X3 Four times redundant Redundancy Settings This is the number of times that a label must be correctly decoded before it is trans mitted Selecting a higher redundancy count makes reading slower but it reduces the probability of reading errors especially when labels of poor definition are used Positive and Negative Bar Codes ZZ Start End Program Menu V2 Positive bar codes V4 Both positive
27. mani AA Program Menu EN WAN cj es MEN Dj se MEN sus WAN WA ASCII 127 D Length 2 oar ere IMIN Program Menu AN EN identification S cosewron UA 46 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Read Mode Settings ZZ Start End Program Menu so Single read St a ON gt read S2 Continuous read Add on lt A acme MANNINI disabled Add on XB watmode EIND 0 25 sec Add on aa Mal EE 0 50 sec Add on XD watmece IA 0 70 sec Single Read When a bar code has been decoded the reader will be turned OFF The reader must be trig gered again to read another label This option and Disable trigger cannot be programmed at the same time Multiple Read When a bar code has been decoded the reader will stay ON for a time as set by read time settings or indefinitely if the trigger switch has been disabled The same label can only be decoded again after the label has not been detected for a number of scans Continuous Read The reader will produce as much data as it can decode whether it is the same or not This mode is mainly used for demonstration and diagnosis Add on Wait Mode Used if UPC EAN with add on is enabled The reader searches within the selected time for a valid add on code If a valid add on code is found the reader transmits the data immediately If nothing is found behind the code the scanner will transmit the data without add on If something is found be
28. nd Program Menu EO Transmit sg CD E1 Do not transmit CD GO Do not gt check CD MIN GEN GE Min data 1 char GF Min data 3 chars Gl Min data 5 chars Enable space es eee AE EE Industrial 20f5 Disable space ek csao Nek Industrial 20f5 Continued on next page 22 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner 20f5 Settings cont Code 20f5 is a variable length symbology with an optional check digit and non printable start and stop charac ter Supported characters include numeric digits 0 to 9 The checksum is calculated as the sum modulo 10 of the numerical values of all the data characters The fol lowing 20f5 codes are supported Industrial 20f5 D 20f5 This symbology encodes a pair of digits in each symbol the number of digits are therefore always an even number Information is carried in the bars and spaces The start and stop pattern in not unique inside the code It is therefore essential to use the fixed length option to prevent partial reads Matrix 20f5 This symbology encodes 1 digit in each character the number of digits can therefore be an odd or an even number Information is carried in the bars and spaces String Format Industrial Interleaved or Matrix 20f5 leading zero data 1 or more digits check digit Options for Code 20f5 e Disable transmission of the check digit e Enable check digit check e Select
29. not check CD Do xmsvse PAINI D1 Do not xmit ST SP RT aa D5 Normal Code 39 D8 Do not xmit CD D9 xwco MMN K Full ASCII Code 39 if possible L Enable concat enation M Disable concat enation 8D Minimum 3 digits 8E Minimum 1 digit Continued on next page 17 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Code 39 Settings cont Code 39 is a variable length symbology with an optional check digit CD and printable start stop ST SP characters The following characters are supported e Numeric characters 0 to 9 e Alpha characters capital A to Z e Special characters and SPACE e Start stop character is The checksum is calculated as the sum modulo 43 of the numerical value of the data characters In full ASCII mode all 128 ASCII characters are supported This is done by combining one of the characters or with one of the alpha characters A to Z String Format start char data 0 or more characters check digit stop char Options for Code 39 e Enable full ASCII conversion e Enable Italian Pharmaceutical conversion e Enable check digit e Disable transmission of the check digit Enable transmission of start stop e Enable leading A for Italian Pharmaceutical e Selection of the minimum number of data characters Normal Code 39 In this mode the decoded data characters are transmitted without further translation Full
30. nu 8J Fi 8K F2 8L F3 8M F4 8N F5 80 F6 8P F7 8Q F8 8R F9 8S F10 8T F11 8U F12 9X Backspace 7H TAB Continued on next page 33 Part III Bar Code Menu Functions Direct Input Keyboard Keys cont 34 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu YA Carriage return 7Q Enter numeric pad 7R Enter make alpha pad 7S Enter make and break alpha pad 7J ESC 7K Arrow down 7L Arrow up 7M Arrow right 7N Arrow left 7T lt DEL gt VQ lt INSERT gt VR lt HOME gt VS lt END gt 70 Page up Continued on next page Part III Bar Code Menu Functions Direct Input Keyboard Keys cont V520 LGP Handheld CCD Scanner wa EN Program Menu P EE Wa EE PW inco RR ME EE V omcso AA X momce EE AN EE OE SEN 35 Part III Bar Code Menu Functions Direct Input Characters 36 V520 LGP Handheld CCD Scanner ZZ Start End Program Menu 5A lt SPACE gt 5B 5C 5D 5E 5F 5G 5H 5I 5J 5K 5L 5M 5N Continued on next page Part III Bar Code Menu Functions Direct Input Characters cont V520
31. ode types can be selected by enabling a single readable code only It is strongly recommended that only the required codes be selected Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Symbology Additions If the scanner will not be used to read all symbologies default setting shorten operation time by using this menu to add only the specific symbologies being used add only the symbologies that are required zz programmers NN go saioen AAA Aa aa Aa aa Bai Ee MONDD es ggs DININ ma aa AE aI eol ke TINI ar aal oa aa ar aa ar aa Continued on next page 10 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Symbology Additions cont ZZ Start End Program Menu R4 Enable EAN R5 Enable EAN 2 R6 Enable EAN 5 Enable aa Mal 2of5 Enable IE Mal 2of5 11 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Setting the Number of Characters to be Scanned ZZ Start End Program Menu Fixed length GN EN all codes Fixed length ME EE all codes Fixed length UR EE selected codes HL Min length selected codes HM Max length selected codes Setting Code Specific Options Options for specific codes may be configured affecting e Enabling and disabling code variants and translations e Data verification such as by mean of a check digit calculation A check di
32. odulo seven of the data string IATA is acronym for International Air Trans port Association String Format A possible format of IATA is as follows Code Description Digits Options for IATA Enable check digit check Selection of the check digit calculation e Disable transmission of the check digit Check Digit If the check digit calculation is required then the appropriate calculation method must be selected 26 CPN AC FC SN CD Coupon Airline Code Form Code Serial Number Check Digit 1 3 2 8 15 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner Telepen Settings ZZ Start End Program Menu Pe j weers N gt D3 j sonmese TIMI Telepen is a variable length symbology with a check digit and non printable start stop characters Supported characters include numeric digits 00 through 99 in numeric mode and all 128 ASCII characters in full ASCII mode The check digit calculation is derived from the sum of all data characters modulo 127 The check digit cannot be transmitted String Format Data 1 to 32 characters Options for Telepen e Selection of full ASCII mode 27 Part III Bar Code Menu Functions V520 LGP Handheld CCD Scanner C Universal Selections ZZ Start End Program Menu GEEN NE YW Convert to upper case YX Convert to lower case ME AA String Options This section describes the alterat
33. slated to ASCII GS hex 1D character String Format C1 data characters lt GS gt data characters Enable EAN 128 Only In the mode the decoded data characters are translated to the EAN 128 format If the data does not comply with the EAJ 128 format then the label is rejected Enable EAN 128 If Possible In this mode the decoded data characters are translated to the EAN 128 for mat If the data does not comply with the EAN 128 format then the label is transmitted as Code 128 FNC2 Concatenation If a Code 128 bar code contains a leading FNC2 character the data is stored into the reader s buffer AS soon as a Code 128 bar code is read without a leading FNC2 character the data is appended to the reader s buffer and the entire buffer is transmitted and cleared for new data In case a non Code 128 bar code is read the data in the non Code 128 bar code is transmitted and the buffer is cleared The buffer size is reader dependent 25 Part III Bar Code Menu Functions IATA Settings V520 LGP Handheld CCD Scanner ZZ Start End Program Menu 4H Do not check CD 7 i oensmo NN 43 orecscen sy MTENNI AK Check CPN airline and S N N GEE AM Do not transmit CD IATA is a variable length symbology with an optional check digit and non printable start stop characters Sup ported characters include numeric digits 0 through 9 The checksum is calculated as the m
Download Pdf Manuals
Related Search
Related Contents
Bosch PSB 500 RE 4X2 DVI Switcher manual.indd 1 - Dodge MANUALE HD impag E (2)、実教出版K・K FERSYSTEM 51 - 101 FERSYSTEM 51i Copyright © All rights reserved.
Failed to retrieve file