Home

USER MANUAL - J.P. Leisure

image

Contents

1. www prolight co uk STAGE COLOUR QUAD Order code LEDJ107 USER MANUAL LEDJ Stage Colour Quad Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty LEDJ Stage Colour Quad Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment e Do not open
2. on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them LEDJ Stage Colour Quad Operation 7 One Way Flow Mode To enter the One Way Flow mode press the MODE button to show PR 05 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 8 Two Way Flow Mode To enter the Two Way Flow mode press the MODE button to show PR 06 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 9 Dream Flow Mode To enter the Dream Flow mode press the MODE button to show PR 07 on
3. One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property LEDJ Stage Colour Quad Technical specifications You should find inside the LEDJ carton the following items 1 Stage Colour Quad Unit 2 Instruction manual 3 Power Cable Technical Specifications DMX channels 4 6 12 or 15 selectable 9 x 8W Ultra Bright Quad colour LEDs Static colour colour mix colour change colour fade auto run slave sound active and DMX modes 400Hz flicker free 3 pin XLR in out sockets 4 push button LED display IEC power in out sockets Beam angle 25 degrees Power supply 240V Power consumption 77W Dimensions 350 x 165 x 255mm Weight 5 8Kgs Operating modes 1 Static colour mode 2 Manual RGBW colour mix mode 3 4 Colour change mode 4 15 Colour change mode 5 Colour fade mode 6 One way flow 7 Two way flow 8 Gradient flow 9 7 colour sound active mode 10 15 colour sound active mode Overview 11 DMX mode O O LED DISPLAY O O DMXIN DMX OUT POWER INOUT 3 FUSE F2A 250V MENU ENTER UP DOWN STAGE COLOUR
4. connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion Bin Ge 3 Pin XLR socket Si gt A Pin 1 GND screen a Pin 2 Signal Q Pin 3 Signal Sen XLR socket i 3 Pin XLR socket a n 1 GND screen Pin 1 SND screen Pin 2 Signal Pin 2 Signal E Pin 3 Signal Pin 3 Signal e pn 2 Kanal Pin 5 N C www prolight co uk
5. the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 10 7 Colour Sound Active Mode To enter the 7 Colour Sound Active Mode press the MODE button to show PR 08 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sensitivity from 00 99 When you are happy with your settings press the ENTER button to confirm them 11 15 Colour Sound Active Mode To enter the 15 Colour Sound Active Mode press the MODE button to show PR 08 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sensitivity from 00 99 When you are happy with your settings press the ENTER button to confirm them LEDJ Stage Colour Quad DMX Charts 4 Channel DMX chart Channel Value Function 000 255 Red 0 100 000 255 Blue 0 100 000 255 White 0 100 6 Channel DMX chart default 1 m e 000 255 Green 0 100 i 000 255 Master dimmer 0 100 001 005 Sound active 15 colours 011 255 Strobe slow to fast LEDJ Stage Colour Quad DMX Charts 12 Channel DMX chart 15 Chan
6. value from 001 255 1 R001 Red 2 G001 Green 3 B001 Blue 3 0001 White NOTE Each colour has a brightness value from 001 255 001 off 255 full on Now press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 4 4 Colour Change Mode To enter the 4 Colour Change Mode press the MODE button to show PR 02 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 5 15 Colour Change Mode To enter the 15 Colour Change Mode press the MODE button to show PR 03 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the speed from 00 99 Press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 6 Fade Mode To enter the Fade Mode press the MODE button to show PR 04
7. QUAD CEX www prolight co uk LEDJ Stage Colour Quad Operation 1 DMX Mode To enter the DMX mode press the MODE button to show A001 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the DMX address from 001 512 Now press the ENTER button again to choose a DMX channel mode using the UP and DOWN buttons You can select one of the four channel modes for operation 04 CH 06 CH 12 CH or 15 CH When you are happy with your choice press the ENTER button to confirm it 2 Static colour mode To enter the Static colour mode press the MODE button to show PR 00 on the LED display Now press the ENTER button and use the UP and DOWN buttons to select one of the static colours from CL 01 CL 15 Now press the ENTER button again and you can then select the strobe speed using the UP and DOWN buttons from FS 00 FS 99 00 off 99 fast When you are happy with your settings press the ENTER button to confirm them 3 Manual RGBW Colour Mix Mode To enter the Manual RGBW Colour Mix Mode press the MODE button to show PR 01 on the LED display Now press the ENTER button and use the UP and DOWN buttons to select Red Green Blue or White To make the colour selection press the ENTER button again and use the UP and DOWN buttons to change the colour
8. is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Stage Colour Quad can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split LEDJ Stage Colour Quad DMX Setup Notice e Be sure to follow figures 2 8 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground o Pin 2 Negative FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to
9. nel DMX chart CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 R1 G1 B1 w1 R2 G2 B2 W2 R3 G3 B3 W3 7 COLOUR SOUND ACTIVE 15 COLOUR SOUND ACTIVE STROBE SLOW TO FAST SENSITIVITY CH1 230 255 DIMMER CH1 0 169 SPEED CH1 170 229 LEDJ Stage Colour Quad DMX Setup DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture
10. the equipment and do not modify the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY