Home
3GHD-OE 3GHD-OE-2 User manual - AV
Contents
1. Figure 7 Dual OE converter standard setup RCL1 PPI RCL2 PRI2 SWP Optical input 1 Reclocker1 21 3G HD SD SDI DOP OVR Optical input 2 Reclocker 2 Liz 3G HD SD SDI Figure 8 Dual OE converter input swap RCL1 PRI1 Optical input 1 Reclocker 1 O1 RCL2 3G HD SD sp TT PRI2 Qi SWP DOP 1 02 OVR Optical input 2 Reclocker 2 02 EE 3G HD SD SDI es Figure 9 Single OE converter with DA input 1 RCL WO PRI1 Optical input 1 Reclocker 1 eil RCL2 3G HD SD sp _ TT PRI2 Qi SWP DOP 1 02 OVR Optical input 2 Reclocker 2 02 3G HD SD SDI 02 Figure 10 Single OE converter with DA input 2 nevion com 11 3GHD OE 3GHD OE 2 Rev 5 4 MADI transport The card can be used to transport MADI signal Nevion recommend setting the cable EQ and rec clocker in bypass nevion com 12 3GHD OE 3GHD OE 2 Rev 5 5 Connections The 3GHD OE and 3GHD OE 2 has a dedicated connector module 3GHD EO 2 C1 This module is mounted at the rear of the sub rack The module is shown in the figure below Devon ce DE OPT1 Figure 11 Connector module for 3GHD OE 2 5 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www nevion com 5 2 Terminal format support The differe
2. LOS LOCK2 No input signal on electrical output 2 Input signal on electrical output 1 but reclocker not in lock Input signal on electrical output 1 and reclocker in lock nevion com Rev 5 16 3GHD OE 3GHD OE 2 Rev 5 7 RS422 commands This card uses the FLP 4 0 protocol to be configured and monitored See separate documents for definition of this protocol 7 1 FLP4 0 block commands Common FLP4 0 block for both single and dual converter is listed below 7 1 1 PIN O Optical input 1 Long haul version supports optical level lt identifier gt pin lt status gt cd ncd lt rssi gt dBm 7 1 2 TEMP 0 Board temperature lt identifier gt temp lt status gt alarm lt temperature gt C ulim lt temperature gt llim lt temperature gt lt block command gt lt upper limit gt lt lower limit gt lt upper limit gt ulim lt temperature gt lt lower limit gt llim lt temperature gt 1 3 PWR 0 zl lt identifier gt pwr lt status gt lt nominal voltage gt Vnom lt voltage gt 7 1 4 PWR 1 lt identifier gt pwr lt status gt lt nominal voltage gt Vnom lt voltage gt 1 5 PWR 2 J lt identifier gt pwr lt status gt lt nominal voltage gt Vnom lt voltage gt 7 1 6 PWR 3 Only for long haul version lt id
3. This is indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labelled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices nevion com 22 mevion EC Declaration of Conformity MANUFACTURER AUTHORIZED REPRESENTATIVE Established within the EEA MODEL NUMBER S DESCRIPTION DIRECTIVES this equipment complies with HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY TECHNICAL CONSTRUCTION FILE NO YEAR WHICH THE CE MARK WAS AFFIXED TEST AUTHORIZED SIGNATORY MANUFACTURER pa 201 NNA om 976 Thomas hrbom Positio VP of Business Support Systems n Nevion authorized signature Nevion Not applicable 3GHD OE 3 GHD OE 2 Single and dual 3G SDI optical to electrical converter Low voltage EU Directive 2006 95 EC
4. hnevion Vlait 3GHD OE 3GHD OE 2 Single and dual 3G SDI optical to electrical converter User manual Rev 5 3GHD OE 3GHD OE 2 Rev 5 Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 5 4 2012 06 12 AJM Updated chapter 3 5 and 6 1 1 4 3 2012 01 20 AJM Added MADI transport chapter 3 2 2011 10 19 AJM Changed optical overload 2 1 2010 03 09 AJM Updated DIP 5 in 3 2 1 0 2009 10 23 AJM Updated DIP 2 4 and 6 in 3 2 0 2009 05 15 AJM First release nevion com 2 3GHD OE 3GHD OE 2 Rev 5 Contents US ie EE 4 1 1 Product WEIEN EE Eed EE 5 2 Specification E 6 2a General EE 6 2 2 Optical TEE 6 23 Electrical CUS eet an ahah eh ace cas a tn cet ee RS R i 6 SEI ee e E 6 SEENEN eege eege 7 3 1 Single converter eeh ee E aaa dee e nne 7 32 Dual CONVENOR asnctmnttadmatinn EE lees 8 DO Reclocket MOJO cial cnud ha eae a ea a a a aa e EE Aaa E a TRAA EERE 9 3 4 Display optical input power
5. long haul version oh 9 3 5 A tomatic change EE 10 3 6 Single converter configuration exvample EEN 10 3 7 Dual converter configuration evample 11 AMA TANS POM EE 12 EE Eeer 13 5 1 Mounting the connector MOGULS ee geheegt Eder ads etieed vee 13 5 2 Terminal f rmat SUDPPOR seinen Au Stes eege dt Ee fe Eed rote estates EE 13 OiMOGUIE SIGS tacthctiitnnctnsisonetieiets dis tea Manta Mas teta Munna Mantnialdui tia intents 15 6 1 GPI ALARM Module Status Outputs vac cccciicccttewesesieteccenventvcatieatuensientwenstednceetventeden tion 15 6 2 Front panel Status MONMOMNG dE eet ee chbeatnieegyeutedebhcats ge Eege er 16 alatet PARo OS CE 17 Tl ELP4 0 block commands E 17 LZ Single GOMVSTIORS soiree enee Deeg dee deeg 18 PaO RUE EEN 18 General environmental requirements for Nevion eoupment 20 Product Warlatily 5 424 poc eS ahhh ead teach E 21 Appendix A Materials declaration and recycling miormaion 22 EC Declaration of Conformity EE 23 nevion com 3 3GHD OE 3GHD OE 2 Rev 5 1 Product overview The Flashlink 3GHD OE and 3GHD OE 2 is a dual multi bit rate optical to electrical converter module providing high performance media conversion for various signal formats from 19 4Mbps up to 2970Mbps Unmatched signal accuracy even in critical applications with pathological signal patterns makes the 3GHD OE and 3GHD OE 2 the first choice for all optical transport demands The 3GHD OE and 3GHD OE 2 can transport all HD and SD signal formats
6. 2 Rev 5 3 5 Automatic change over Dual optical converter has an automatic changeover module This module has the possibility to have an automatic change over on the input This can be used in redundancy systems where the user wants automatically switch to a backup port when the main input loses signal This function can be turned with DIP 5 From GYDA this function can be turned on for each converter Each converter can be configured to what is main and backup input by DIP 2 and DIP 4 or from GYDA 3 5 1 Trigger condition Loss of optical power trigs the automatic change over When the main input loss optical power the backup input is selected When the backup input is active an alarm is displayed in Gyda When the main input optical power is restored the converter switches immediately back to main input and the alarm is restored Note that bit error or loss of lock on reclocker does not trigger the ACO 3 6 Single converter configuration example RCL1 PPI RCL2 PRI2 SWP Optical input Reclocker 3G HD SD SDI DOP OVR Figure 5 OE converter with reclocker RCL1 PRI1 RCL2 PRI2 SWP Optical input DOP OVR Figure 6 OE converter with reclocker in bypass nevion com 10 3GHD OE 3GHD OE 2 Rev 5 3 7 Dual converter configuration example DCL E PRI1 Optical input 1 Reclocker 1 01 RCL2 3G HD SD sp TT PRI2 Qi SWP DOP Lo OVR Optical input 2 Reclocker2 Li 3G HD SD SDI
7. EMC EU Directive 2004 108 EC RoHS EU Directive 2002 95 EC China RoHS WEEE EU Directive 2002 96 EC REACH EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 Notified Competent Body Report no Nemko E08463 Not applicable 2008 AUTHORIZED REPRESENTATIVE Date of Issue Established within EEA 2010 03 09 Place of Issue Not applicable Sandefjord Norway 1 Administration on the Control of Pollution Caused by Electronic Information Products Nevion HQ Nevion Europe P O Box 1020 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 www nevion com
8. for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connector is shown in figures below Electrical Maximums for GPI outputs Max current 100mA Max voltage 30V 6 1 1 GPI connections 3GHD OE 2 module GPI pinning Signal Name Pin Mode Status General error status for the module Pin 1 Open Collector This is normally closed LOS1 Loss of signal on input 1 Pin 2 Open Collector LOS2 Loss of signal on input 2 Pin 3 Open Collector Ground OV gnd pin Pin 8 ON Figure 1GPI connector nevion com 15 3GHD OE 3GHD OE 2 6 2 Front panel Status monitoring The status of the module can be easily monitored visually by the LED s at the front of the module The LEDs are visible through the front panel as shown in the figure below The 3GHD OE 2 has 4 LED s each showing a status corresponding to the GPI pinning O STATUS LOS LOCK1 LOS LOCK2 When DIP 7 is on the LEDs are used as an optical power meter is OK Diode State Red LED Yellow LED Green LED No light Status Module is faulty or N A Module is Ok Module module is initializing Module power has no power LOS LOCK1 No input signal on electrical output 1 Input signal on electrical output 1 but reclocker not in lock Input signal on electrical output 1 and reclocker in lock
9. in addition to DVB ASI and SMPTE 310M It performs optical refreshing and signal re clocking which is selectable on application The optical input comes with a sophisticated PIN diode with a sensitivity typically better than 20dBm operating in the 1200 1620nm wavelength range The module is also available as a long haul version with typically 30dBm sensitivity The open system platform of Nevion Flashlink system allows easy interoperability with third party fibre optical systems The 3GHD OE and 3GHD OE 2 unit has also three electrical outputs for each converter which reduces the need for additional DA s Output 1A Optical receiver Optical g Input 1 GJ Reclocker Output 1B Output 1C 19 4 2970Mbps Output 1D Output 1E Output 1F Microcontroller Remote Control Figure 1 Block diagram of the 3GHD OE converter nevion com 4 3GHD OE 3GHD OE 2 Rev 5 Optical receiver OutpUtTA AA OP Output 1B Bypass Output 1C 19 4 2970Mbps 19 4 2970Mbps Optical receiver Output 2A Gs 2 Output 2B Output 2C Remote Control Figure 2 Block diagram of the 3GHD OE 2 converter 1 1 Product versions Available in the following versions 3GHD OE Single converter 3GHD OE long haul Single converter long haul 3GHD OE 2 Dual converter 3GHD OE 2 long haul Dual converter long haul nevion com 5 3GHD OE 3GHD OE 2 2 Specifications 2 1 General Power Control Temp range 2 2 Optical Input Nu
10. 009 one X 7 ih m me A He STATUS F of AP C o i a LOS LOCKS a 7 o0000 Ca 3 e CG g d LOs Lock2 X ra A ji e g eg A AQL ITT Ga E N H a x D LA S Ubu Figure 4 3GHD OE 2 board layout Switch Function DIP ON Function DIP OFF 1 RCL1 Reclocker 1 ON Reclocker 1 bypass Reclocker mode for output 1 2 PRI1 Select input 2 Select input 1 Selects input or in ACO mode selects main input for output 1 3 RCL2 Reclocker 2 ON Reclocker 2 bypass Reclocker mode for output 2 4 PRI2 Select input 2 Select input 1 Selects input or in ACO mode selects main input for output 2 5 SWP Automatic change Normal operation See chapter 3 5 over Automatic change over 6 TI Select input 2 Select input 1 Selects input for DOP 7 All LED showing LED s normal operation See chapter 3 4 optical input power Display optical input power OVR Override GYDA GYDA control Select configuration control Configuration with from GYDA Configuration with GYDA DIP switch All DIP switches are off when pointing towards the release handle nevion com 8 3GHD OE 3GHD OE 2 Rev 5 3 3 Reclocker mode The reclocker can be set to reclock or bypass from DIP 1 and DIP 3 or from GYDA When reclocker is set to reclock mode jitter from the signal is removed Accepted bitrates is 270 1483 5 1485 2967 and 2970Mbps When reclocker is set to bypass the converter accept all bitrates between 19 4 to 2970Mbps Note that in
11. angeover mode gt lt priority list gt lt block command gt lt set position gt lt set priority gt lt changeover mode gt auto man lt priority list gt pri lt input gt lt set position gt DOS auto man lt input gt lt set priority gt D I lt input gt 7 3 4 RCL 0 Reclocker for output 1 lt identifier gt rcl lt status gt en mute bypass lock lol lt bitrate gt Mbps asi sdi hdsdi abp on off rate man auto lt block command gt lt set mode gt lt set autobypass gt lt set mode gt en mute bypass lt set autobypass gt abp on off 7 3 5 RCL 1 Reclocker for output 2 lt identifier gt rcl lt status gt en mute bypass lock lol lt bitrate gt Mbps asi sdi hdsdi abp on off rate man auto lt block command gt lt set mode gt lt set autobypass gt lt set mode gt en mute bypass lt set autobypass gt abp on off nevion com 19 3GHD OE 3GHD OE 2 Rev 5 General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range lt 90 non condensing 2 The equipment will operate without damage
12. entifier gt pwr lt status gt lt nominal voltage gt Vnom lt voltage gt nevion com 17 3GHD OE 3GHD OE 2 Rev 5 7 2 Single converter FLP4 0 block for single converter is listed below 7 2 1 RCLO Reclocker for output 1 lt identifier gt rcl lt status gt en mute bypass lock lol lt bitrate gt Mbps asi sdi hdsdi abp on off rate man auto lt block command gt lt set mode gt lt set autobypass gt lt set mode gt en mute bypass lt set autobypass gt abp on off 7 3 Dual converter FLP4 0 block for dual converter is listed below 7 3 1 PIN 1 Optical input 1 Long haul version supports optical level lt identifier gt pin lt status gt cd ncd lt rssi gt dBm 7 3 2 CHO 0 Input select for output 1 lt identifier gt cho lt status gt lt input gt size 2 lt changeover mode gt lt priority list gt lt block command gt lt set position gt lt set priority gt lt changeover mode gt auto man lt priority list gt pri lt input gt lt set position gt DOS auto man lt input gt lt set priority gt pri lt input gt nevion com 18 3GHD OE 3GHD OE 2 Rev 5 7 3 3 CHO 1 Input select for output 2 lt identifier gt cho lt status gt lt input gt size 2 lt ch
13. mber of inputs Data rate optical Sensitivity short haul Sensitivity long haul Input overload short haul Input overload long haul Detector damage threshold Optical wavelength Transmission circuit fiber Connector return loss Connector 2 3 Electrical Outputs Number of outputs Connector Impedance Return loss Peak to peak signal level Signal polarity 2 4 Standards Rev 5 5V DC 3 2W max Control system for access to setup and module status with BITE Built In Test Equipment 0 to 40 C 1 on single converter 2 on dual converter 19 4 to 2970Mbps 20dBm 30dBm with laser extinction ratio gt 10 1 DWDM 28dBm CWDM SD HD 3dBm 3G 5dBm 7dBm gt 0dBm 1200 1620nm Single mode 9 125um gt 40dB w SM fiber SC UPC 6 on single converter 3 per converter on the dual converter BNC 75 ohm gt 15dB 5 1485MHz gt 10dB 1485 2970MHz 800mV 100mV 2 inverting 4 non inverting on single converter 2 inverting 1 non inverting per converter on dual converter Supported standards for electrical and optical ports SMPTE292M SMPTE259M SMPTE297M SMPTE305 2M SMPTE310M SMPTE424M DVB ASI EN50083 9 nevion com 6 3GHD OE 3GHD OE 2 Rev 5 3 Configuration 3 1 Single converter The 3GHD OE can support a number of different broadcast formats The correct configuration can either be set with a DIP switch or with the GYDA Control System The layout of 3GHD OE is shown in the drawing bel
14. nt input and output ports on 3GHD OE and 3GHD OE 2 can support a number of formats The table below show which signal formats are supported on the selected terminals Terminal format support for single converter OPT1 Optical input SDI DVB ASI Input SMPTE310 Transparent 1 01 Electrical Output SDI DVB ASI Transparent Output 1 02 Reclocked DA output O O 1 2 OT Electrical Output SDI Transparent Output O2 Reclocked DA inverted O O output GPI ALARM Open Collector Alarms OC Output nevion com 13 3GHD OE 3GHD OE 2 Rev 5 Terminal format support for dual converter OPT1 Optical output SDI DVB ASI Output OPT2 SMPTE310 Transparent 1 01 Electrical Output SDI DVB ASI Transparent Output 1 02 Reclocked DA output O1 O02 Ee Electrical Output SDI Transparent Output Reclocked DA inverted O2 output GPI ALARM Open Collector Alarms OC Output Unused inputs should be terminated to avoid alarms triggered by noise nevion com 14 3GHD OE 3GHD OE 2 Rev 5 6 Module status The status of the module can be monitored in three ways 1 GYDA System Controller optional 2 GPI at the rear of the sub rack 3 LED s at the front of the sub rack Of these three the GPI and the LED s are mounted on the module itself whereas the GYDA System Controller is a separate module giving detailed information on the card status 6 1 GPI ALARM Module Status Outputs These outputs can be used
15. ow with the DIP switch to the upper left position Se Een ee Last aw a oS A A7 be BCL 3 KC GE Mooon X p _ 1 AN ek A SEH es 5 status CH a if D 2 o LOS LOCKS Sa cae m S i 2 LOS LOCK2 X d L cb d Se AIAN N E gt ean CU h E we x See Figure 3 3GHD OE board layout Switch Function DIP ON Function DIP OFF Comment RCL1 Reclocker 1 ON Reclocker 1 bypass EE mode for output 1 DI No function on this product 3 RCL2 No function on this product 4 PRI2 No function on this product No function on this GE esche LED ee EEN s normal operation See 3 4 aes optical input power optical input power Override GYDA GYDA control Select configuration control Configuration with from GYDA Configuration with GYDA DIP switch All DIP switches are off when pointing towards the release handle nevion com 7 3GHD OE 3GHD OE 2 Rev 5 3 2 Dual converter The 3GHD OE 2 can support a number of different broadcast formats The correct configuration can either be set with a DIP switch or with the GYDA Control System The layout of 3GHD OE 2 is shown in the drawing below with the DIP switch to the upper left position AN IR be a iF ll Lg ae POERA TU 7 Gg f a N sl Seit sh ooo
16. this mode the jitter is not removed and this can cause problems for equipment following the converter 3 3 1 Transparency This converter only looks at the bitrates and not the content This means that any signal with correct bitrates is converted The product is transparent to data in the ancillary space like embedded audio 3 4 Display optical input power long haul version only On the long haul version the LEDs can be used as an optical power meter This is practical under installation of the module The power measurement is not accurate but can be used as an indication of optical signal strength Remember to turn this function of after installation When all LEDs are green the optical input power is more than 6 5dBm When all LED are off input power is below 25dBm The DOP can only be turned on from the DIP DOP is turned on by DIP 7 and DIP 6 select input port Optical input power Status LED LOS lock1 LED LOS lock2 LED More than 6 5dBm Green Green Green Green 7 0dBm to 8 5dBm Yellow Green Green Green 9 0dBm to 10 5dBm Red Green Green Green 11 0dBm to 12 5dBm Green Green Green 13 0dBm to 14 5dBm Yellow Green Green 15 0dBm to 16 5dBm Red Green Green 17 0dBm to 18 0dBm Green Green 18 5dBm to 19 0dBm Yellow Green 19 5dBm to 20 0dBm Red Green 21 0dBm to 22 0dBm Green 23 0dBm to 24 0dBm Yellow Below 25dBm Red nevion com 9 3GHD OE 3GHD OE
17. under the following environmental conditions Temperature range 10 C to 50 C Relative humidity range lt 95 non condensing nevion com 20 3GHD OE 3GHD OE 2 Rev 5 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 21 3GHD OE 3GHD OE 2 Rev 5 Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements MRE Fi SS ACME SRK SS ER Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE 3GHD OE 3GHD OE 2 O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T1 1363 2006 O O O O O O X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006
Download Pdf Manuals
Related Search
Related Contents
The MESSy submodels IMPORT and GRID VZ-HD4000A VZ-HD4900A - Hitachi America, Ltd. Eight-Channel Programmable Filter and Gain Signal Conditioning User manual: Vista VK2-1080BXDNe CDA FW221 refrigerator bombas dosificadoras serie pkx cc/m Baha® Connect System 取扱説明書等 - アイ・オー・データ機器 Copyright © All rights reserved.