TCP/IP driver for Mitsubishi Q/FX3-series Ethernet

image

Contents

1. Do not connect initially to alllnodes when driver is started Connection Types The Connect directly One IP Address one node and Connect directly One IP Address multiple nodes options are designed for use on fixed ADSL SDSL WIFi etc type networks where the PC and the PLC is connected permanently e f you select the Connect directly One IP Address one node option each node you create will require its own interface under the driver e f you select the Connect directly One IP Address multiple nodes option you can create multiple nodes for the selected interface The GPRS One IP Address one node and GPRS One IP Address one nodes options are is designed for use on GPRS type network where the user is charged for the amount of data being transmitted on the network See the Use with GPRS networks section for a description on this option e f you select the GPRS One IP Address one node option each node you create will require its own interface under the driver e f you select the GPRS One IP Address multiple nodes option you can create multiple nodes for the selected interface Schneider Adding a new Node After you have created a new interface you can create a new node To add new node to a driver in the left pane of the System Configuration form right click the IPNetwork 0 interface under the Mitsubishi Q FX Series driver and select New Int
2. 16 Enable the GPRS connection 17 Performance Halte elle LEE 18 Schneider Electric IGSS Automation Bistruphave 3 DK 3460 Birkered Denmark Phone 45 45 900 700 www schneider electric com VAT no DK 73 63 41 13 Schneider Introduction This document describes how to set up and troubleshoot the IGSS 7TMITETH Interface Driver The IGSS program must be installed as an IGSS Server on the machine which is to be the IGSS Server and a functioning network of personal computers and PLCS must be in place prior to installing and configuring the driver Driver Files The following files are used set up and troubleshoot the IGSS 7TMITETH driver e 7TMITETH DLL Contains the protocol stack required for communication with Mitsubishi FX and Q PLCs using ethernet TCP IP interfaces e 7TMITETHc DLL Contains the graphical user interface used to configure the 7TMITETH driver Driver89 reg Contains the required information which must be correctly updated in the Windows registry in order for the IGSS program to make use of the driver The files are usually located in the GSS folder of the IGSS installation Default IGSS installation folder The default IGSS installation folder is e For 32 bit machines C Program Files Schneider Electric IGSS32 lt IGSS Version e For 64 bit machines C Program Files x86 Schneider Electric IGSS32 lt IGSS Version gt If you have installed IGSS Vers
3. i File versions ZS Driver DLL File 7TMITETH DLL Version 11 00 00 build 14255 La Configuration DLL File 7TMITETHC DLL Version 11 00 00 build 14255 For Help press Fl Schneider Adding new PLC machines When a new PLC machine is added you can add a new node representing the PLC to the driver in the left pane of the System Configuration form Adding a new Interface You must first create an interface to contain the node but once created an interface can contain one node or many nodes The 7TMITETH driver is designed to use one IP address for each node or one IP address for multiple nodes and you must select one of the connection type options Connect directly One IP Address one node Connect directly One IP Address multiple nodes GPRS One IP Address one node GPRS One IP Address multiple nodes IGSS System Configuration C IGSS Configs IGSS11Configs V11 Demo_MobileApp Demo File Edit View Tools Help H 221022 80 Project name Demo Connect Through IP Network Remote SC IGSSSVR 1 amp Generic TCP IP Driver Connection type 1 amp Mitsubishi Ethernet TCP IP driver H 0 9 MODBUSIGPRS diver 2 Connect directly One 5 58 OMRON FINS Ethernet driver Connect directly One IP address muttiple nodes 1 amp Siemens S7 TCP IP protocol driver C GPRS One IP address one node OP1 GPRS One IP address multiple nodes 2
4. Mitsubishi Q Series memory variables Special Register Link Register Spec Link Register File Register Index Register Timer Value Counter Value Intg Timer Value Input Relay Direct Input Output Relay Direct Output Internal Relay Latch Relay Annunciator Edge Relay Link Relay Timer Contact Timer Coil Intg Timer Contact Intg Timer Coil Counter Contact Counter Coil Spec Link Relay Step Relay Mitsubishi FX3 Series memory variables Data Register Extension Register Timer Value Counter Value Input Output Internal Relay Timer Contact State The memory variables are accessible in the Device field on the Edit Mapping tab of the Object Properties form for the individual object atom Schneider Analog Data Management Definitions Display Layers Edit Mapping Calculation Report Format Symbol Definition PLC Node for object Mitsu Driver 7TMITETH IGSSSVR Actual Value Set Point Node o EI Low Limit Low Alarm Address for Actual Value atom en i Device High Scale Data Register Low Scale Number Extension Register Timer Value Free Value 1 Addressil Counter Value Free Value 2 Input Free Value 3 Device Output Address Intemal Relay Timer Contact Bit Offsel Counter Contact State External type 1 0 mode in z Use numeric to scroll to next previous atom U
5. Display Layers Edit Mapping Calculation Report Format Symbol Definition Atom PLC Node for object Data register 0 Hoh Alarm Beggen ver 7TMITETH DemoStation Bees F Set Point Node 0 F Low Limit Fl Low Alarm PLC Address for Actual Value atom Alarm In Alarm Out High Scale Low Scale Number Free Value 1 Free Value 2 Addressing Word 16 bit gt Free Value 3 Device Address Device Data Register Bit Offset 0 External type Use numeric to scroll to next previous atom Now select the desired PLC node number and continue by setting be desired Device Then specify the number register number within the device type Note that the corresponding Mnemonic is displayed and updated as you select the appropriate parameters This is a help to make sure you always bind to the correct process variable Continue this process for each atom on the object and save the parameters by clicking the OK button when finished Supported PLC registers Schneider The Mitsubishi driver supports a number of different PLC memory variables Note that the memory variables will vary depending on the type of Mitsubishi PLC FX3 or Q series The list below conforms to the Mitsubishi PLC Q Series The memory can be addressed in the area 0 131071
6. GPRS One IP address one node or GPRS One IP address multiple nodes options in the Connect Through IP Network tab in the right pane of the System Configuration form IGSS System Configuration C MGSS Configs IGSS11Configs V11 Demo_MobileApp Demo File Edit View Tools Help aj aema e Project name Demo Connect Through IP Network Hugs E IGSSSVR a Generic TCP IP Driver Connection type Mitsubishi Ethernet TCP IP driver 0 8 MODBUS GPRS driver 1 amp Siemens S7 TCP IP protocol driver 1 2 Connect directly IP address one node Connect directly One IP address multiple nodes GPRS One IP address one node C GPRS One IP address multiple nodes Do not connect initially to all nodes when driver is started When the GPRS options are selected you can design a schedule which the driver will use when connecting to the PLC node In the left pane select the node and in the right pane of the System Configuration form click the Remote Connection tab IGSS System Configuration C MGSS Configs IGSS11Configs V11 Demo_MobileApp Demo File Edit View Tools Help Hl aeea ele a name Demo Node Properties Identification Remote Connection Connection Misc Advanced E IGSSSVR a Generic TCP IP Driver Configure remote connection to node 1 amp Mitsubishi Ethernet TCP IP driver Bl as r I
7. To IGSS Mitsubishi FX Q TCP IP Interface Driver User Manual Schneider Electric Denmark A S Schneider Electric IGSS Automation Bistruphave 3 DK 3460 Birker d Denmark Phone 45 45 900 700 www schneider electric com VAT no DK 73 63 41 13 Schneider Disclaimer The information provided in this documentation contains general descriptions and or technical characteristics of the performance of the products contained therein The documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications It is the duty of any such user or integrator to perform the appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific application of use thereof Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein The information contained herein is the property of Schneider electric and is supplied without liability for errors or omissions If you have any suggestions for improvements or amendments or have found errors in this publication please notify us No part of this document may be reproduced in any form or by any means electronic or mechanical including photocopying without express written permission of Schneider Electric All pertinent state regional and local safety regulations
8. comes at the price of not actually being connected continuously In the Connection hold time group you might want to specify how long the driver should keep the connection open it either the user sends a command or if the user forces the driver to establish a connection through a dialup connection object The Normal connect hold time check box allows you to define how many seconds the driver will stay connected online if the user forces the driver to make a connection to the PLC The Send cmd connect hold time check box allows you to specify how many seconds the driver will stay online one the PLC node after the user has send a command This latter is useful if the user should be able to see the response of the command which he she has just sent Performance and Throughput The driver is designed for maximum throughput on a LAN WAN network On a standard PC with a standard NIC you should expect a throughput of 20 request response cycles pr second Each PLC node is handled concurrent and independently This means if you add more PLC s to the system then the throughput pr PLC should only be affected marginally provided that the PC NIC throughput is sufficient The IGSS communication engine optimizes communication throughput by seeking to group data whenever possible Therefore if the communication engine is required to read e g DM0001 and DM0031 then it will read data registers DM0001 DM0002 DM0031 as a block This is m
9. DEC address a EE pcr Ee MELSOFT connection v MELSOFT connection Sasa Send EE MEN NI CREE NE o Cancel Note In some cases the port number will be displayed in Hexidecimal values instead of Decimal values in the FX Configurator EN form If this is the case you must re calculate the decimal value of the port number and use the decimal value in the Node properties tab in the System Configuration form in IGSS as IGSS does not display port numbers in Hexidecimal values Once you have set up the Mitsubishi PLC and the Driver Interface Node properties in the System Configuration form in IGSS you can start creating and addressing objects in the IGSS configuration to connect to the Mitsubishi PLCs in order to send and retrieve data from them Schneider Object Configuration Once the driver and the PLC nodes have been defined IGSS Objects and Atoms can be linked to process variables in the PLC Various different types of PLC memory can be accessed for read write operations using the driver By using the Edit Mapping tab in the Object Properties form you can specify the binding between the object s atoms and the PLC process variables Start by selecting an atom and select the 7TOMRTCP driver in the Driver drop down list n Object Properties Data register 0 Global Analog Data Management Definitions
10. PNetwork 0 m Specify parameters to be used to connect remotely to the PLC node MODBUS GPRS driver Phone number Extra AT commands for the modem 8 Siemens 57 TCP IP protocol driver Bopi mi OP2 Connection scheduling Specify when the should connect to the PLC for retrieval of historical data Connect at specific points in time Connect at these times Edit Connect at fixed time intervals Time interval between connections minutes 1440 I Connection hold time Spefify how long time the connection should stay open for both connection types Normal connect hold time seconds 300 Send cmd connect hold time seconds 30 Schneider In the Connection Scheduling group you can design a connection schedule either by entering specific points in time during the day where the driver will establish connection or you can enter a fixed time interval where the driver will establish connection or a combination of both specific points in time and fixed intervals Based on this schedule the driver will connect to the PLC and read all configured data points i e all the tags you have defined in that node Once the driver have read all the data it will stay idle until the next scheduled connection Using this schedule dramatically reduces the amount of data on the wire but of course this
11. erface Depending on the Interface connection type parameters the new node will be created in the IPNetwork 0 interface or in a new interface IPNetwork 1 e If the Connect directly One IP address one node or the GPRS One IP address one node options are selected a new interface will be created for each node e f the Connect directly One IP address multiple nodes or the GPRS One IP address multiple nodes options are selected one interface can contain many nodes 4 1655 System Configur File Edit View Tools Help Ball Ss pn 29v Project name 7tmiteth Identification Advanced Be a DemoStation 5 8 Mitsubishi Ethernet TCP IP dri Connection Properties r IPNetwork _ Specify IGSS node number for this node 5 IPNetwork Se en Set communication parameters for this IGSS node IP address e g 172 16 17 31 192 168 11 55 PLC type Q Series TCP port number 5000 Station number 0 Timeout in milliseconds 3000 Protocol Properties Increase telegram retries if driver generates frequent communication alarms Normally 3 telegram retries are sufficient Telegram retries 3 Set Default m For Help press F1 Each new node is a new PLC driver with first node being numbered 0 Naming Nodes PLC s in the System Configuration form You can add a unique name and description to the node in the Identification tab of the Node parameters in the right pane of the System Configuration
12. form Schneider L IGSS System Configuration C IGSS Configs IGSS11Configs V11 Demo MobileApp lDemo File Edit View Tools Help Hl aema Project name Demo Node Properties Identification Advanced ERC Icsssvr 8 Generic TCP IP Driver E Mitsubishi Ethernet TCP IP driver r Name will appear in alarm list E r IPNetwork 0 Mitsubishi 1st Floor Node 0 Mitsubishi 1st Floor H MODBUS GPRS driver r Description 1 amp OMRON FINS Ethernet driver The Main Mitsubishi FX3 series PLC on the 1st floor near the rear exit H Siemens S7 TCP IP protocol driver opi m 2 Note that the node name will only be displayed in the System Configuration form and will not be displayed in the Edit Mapping tab of the Object Properties form in the Definition module Note The Mitsubishi driver can support up to 64 nodes After you have created the new node you can configure the node setting the required node options and parameters in the Node Properties Identification and Advanced tab pages in the right pane of the System Configuration form Node Parameters The following table describes some of the parameters you can define for the node Field Description IP node number The number of the node which is used as a reference for the PLC This node number is necessary when connecting an IGSS atom tag to a data register address in the PLC You can select a
13. gned the Driver ID 89 in the IGSS program and can be seen and selected in the System Configuration form when setting up the IGSS configuration Once the IGSS program has been installed on the IGSS Server machine and the IGSS Master has been started the configuration which is to use the 7TMITETH driver can be opened in the IGSS Master and set up in the System Configuration form Automatic Installation The driver is normally installed when IGSS is installed To verify that the driver has been installed correctly open the System Configuration form In the left pane of the System Configuration form select an IGSS station and click Edit gt New Driver or right click the station and select New Driver The 7TMITETH driver Driver 89 should be found in the list of available drivers in the Select Communication Driver form Schneider Select Communication Driver Z Select a communication driver to be installed from the list below Then click OK Driver imi 7TL2FMS BI 7TLEGO Ie 7TMELFX iB 7TMELSQ iml 7TMIT s 7 7TMITTCP 7 7TMOD 7TMODEXT 7TMODGPRS BI 7 7TNLINK BI 7TNLOG 7 Soup By 7TOMRTCP 7 Descrip Profibus FMS protocol driver 155532 Datafile Driver Mitsubishi Melsec FX Serial protocol driver Mitsubishi Melsec Q Serial protocol driver Mitsubishi Melsec A protocol driver Mitsubishi Q FX Ser
14. ies Mitsubishi Melsec A TCP IP protocol driver TCP IP Driver for MJK Data Transmitter Modicon Modbus protocol driver Modicon Modbus protocol driver with extended functions MODBUS GPRS driver MODBUS TCP driver NetLinK Driver NEWLOG Interface Driver 155532 ODBC Interface Driver Omron Sysmac Way interface driver OMRON FINS Ethemet driver OPC OLE For Process Control Client side driver If the 7TMITETH driver is present in the Select Communication Driver form you can proceed to the Driver Configuration chapter If the 7TMITETH driver is not present in the Select Communication Driver form you must install the driver manually See Manual Installation below Manual Installation You can manually install the 7TMITETH driver if it is not present in the IGSS installation by following the process described below You must stop the IGSS configuration in order to install the driver and you must have Local Administrator rights on the local machine in order to make the necessary changes to the machine registry as well as update files in the Program Files folders if that is where IGSS has been installed To manually install the 7TMITETH driver 1 Copy the following files to the IGSS installation folder 7TMITETH dIl b 7TMITETHc dll 7TMITETH reg 2 Locate the 7TMITETH reg file and double click the file to update the windows registry settings You can also open the Windows Registry Editor and import the file from the W
15. indows Registry Editor Schneider Driver Configuration This section describes how to configure the driver parameters All driver parameters and set up options are configured in the System Configuration form The System Configuration form is opened by clicking the System Configuration button in the IGSS Master gt Design and Setup tab Note The IGSS configuration must be stopped and restarted for the configured driver parameters to take effect Configuring the driver Once the driver has been added to the station you can configure the driver creating and setting up the interface and nodes of the 7TMITETH driver In the left pane of the System Configuration form select the station IGSS server or Operator Station with Distributed Driver and expand the driver list under the station Select the Mitsubishi Q FX Series driver If the Mitsubishi Q FX Series driver is not present add the driver by right clicking the station and selecting New Driver In the Select Communication Driver form select the 7TMITETH Mitsubishi Ethernet TCP IP driver Driver ID 89 r Y 1 1655 System Configuration c igss_cust test_drv_89_7tmiteth 7tmiteth m So File Edit View Tools Help sz woxx Project name 7tmiteth Driver Information Advanced Extemal Types B a DemoStation Mitsubishi Q FX Series Driver information Mitsubishi Q FX Series Driver Id 89 Statistics Top nodes 0 Sub nodes 0
16. ing response In these cases the Ping command cannot be utilized for verification of the internet connection Mitsubishi Installation The following descriptions are based on one of many Mitsubishi installation tolls for the PLC You can use other installation tools but be aware that each installation tool may differ from the others in specific areas PLC Setup You must set up a connection for communication to IGSS in the PLC You can use the Mitsubishi PLC programing software GX Developer or another tool with the same functionality to set up the connection In the Mitsubishi PLC you must define the Communication data code and the communication connection type The following descriptions use the FX Configurator EN form for configuring the Mitsubishi PLC The FX Configurator EN form is part of the Mitsubishi software package developed for integration and control with the Mitsubishi PLCs and is either part of the PLC delivery package or can be obtained from the Mitsubishi Corporation The FX Configurator EN form is not a part of the IGSS software package and cannot be requested from the IGSS development team or from the Schneider Electric Corporation Schneider Electric Communication data code The communication data code must be set to Binary in the FX Configurator EN This is done to ensure the binary version of the Mitsubishi MC protocol is used for communication Bi FX Configurator EN C MELSEC cbr fen Ethernet operatio
17. ion 11 the lt IGSS Version gt folder name will be V11 0 Software Requirements The 7TMITETH driver is designed to be used with IGSS version 10 or higher The 7TMITETH driver uses the standard Microsoft TCP IP protocol stack The protocol is normally installed in all Microsoft operating systems and can be used as it is DNS and other support protocols are not used by the driver and do not need to be installed or configured The 7TMITETH driver uses the ISO transport layer on top of the TCP IP protocol as it is defined in the RFC This means the TCP IP port must be accessible and opened for use If you are employing a firewall please be aware that the port used for TCP IP communication must be open for bi directional connections If the network addresses from the IGSS program to the PLC machines include more firewall all of these must be configured correctly to allow bi directional TCP IP communication Schneider Electric Hardware Requirements The 7TMITETH driver requires a standard Ethernet Network Interface Controller NIC interface with TCP IP UDP IP installed in the PC which contains the IGSS program The IGSS Mitsubishi Ethernet driver can connect with Mitsubishi PLC machines Q series or FX3 series An Ethernet port supporting TCP IP UDP IP is required on the Mitsubishi PLC s Please refer to Mitsubishi documentation for cable setup and wiring instructions Installation The IGSS 7TMITETH Interface Driver is assi
18. must be observed when installing and using this product For reasons of safety and to help ensure compliance with documented system data only the manufacturer should perform repairs to components Failure to use Schneider Electric software or approved software with our hardware products may result in injury harm or improper operating results Failure to observe this information can result in injury or equipment damage 2004 2014 Schneider Electric All rights reserved Schneider Electric 7 Technologies A S Bistruphave 3 DK 3460 Birker d Denmark Phone 45 45 900 700 www schneider electric com VAT no DK 73 63 41 13 Schneider Contents ME un 2 NEE 4 Bud E 4 Software Requirements suisid t eed uec 4 Hardware e UC 5 ati Eile TEE 5 Automatic Installation eite ihe te icona teen faeta te hito ater iens 5 6 Driver EE 7 Configuring TE 7 Adding gt de 8 KT 10 Testing Rin Ree lee TEE 11 MITSUBISHI EE 11 PLG Setup EE 11 Object Conte Rd sted 14 Supported PLC registers 2 10000400 aii raaa aan aaie 15 Use with GPRS
19. nal settings File View Help Initial timing Do not wait for OPEN Communications impossible at STOP time ASCII code g Always wait for OPEN Communication possible at STOP time address 1 Send frame setting Input format DEC Ethernet v2 0 IP address 802 3 TCP Existence confirmation setting C Use the KeepAlive Use the Ping Cancel Connection type Configure the connection type to be used when connection to and communicating with IGSS in the FX Configurator EN In the FX Configurator EN form select the following e Protocol TCP e Open System Unpassive Schneider e Fixed Buffer Send e Fixed buffer communication procedure Procedure exist MC e Pairing Open Disable e Existence confirmation No confirm e Hold station Port No DEC 5000 The defined port number in the PLC Hold station Port No DEC must correspond to the defined port number in the Node properties tab in the System Configuration form in IGSS It is also important to verify that any firewalls and other net connection based security software permit TCP IP communication through the defined port Bi FX Configurator EN C MELSEC cbr fen Ethernet open settings File view Help Transmission Fixed buffer Pairing Existence Host station Transmission aada Protocol Open system Fixed buffer communication s 2 target device IP open confirmation Port No procedure
20. ny number for the selected node from the drop down list in the IGSS node number field on the Node Properties tab in the right pane of the System Configuration form IP Address The IP address of the PLC node In the example in the screen shot above the IP address is 192 168 11 55 PLC Type Define the type of the Mitsubishi PLC Select between Q series of the FX3 series dependent on the PLC type TCP port number Define the port which has been enabled for TCP IP communication with the Mitsubishi PLC Station number The station number of the PLC The default station number is O Timeout in The timeout parameter defined as milliseconds Schneider milliseconds The driver will return a timeout error if it is unable to connect to the PLC within the defined time On GPRS networks the Timeout in milliseconds value should be increased as connection times to the node can be longer than on Ethernet networks Telegram retries Define the amount of telegram retries if the driver generates frequent communication alarms The Default value is 3 Testing the connection When the PLC and the IGSS Station machine are connected on a network and both are running you can verify the IP address by u sing the PING command in a command prompt See the example below Example in a command prompt gt ping 192 168 11 55 Note that some firewalls will not allow the ping command and the p
21. se with GPRS Networks The IGSS Mitsubishi Ethernet TCP IP driver is primarily designed for use with fixed type Ethernet Networks e g industrial LAN or WAN Networks where the PC and the Mitsubishi PLC s are considered to be directly connected However the 7TMITETH interface driver can also be used on other types of IP based networks as for example GPRS networks GPRS networks basically work as a normal IP network except that there will be a toll cost associated with the amount of data you transmit on the network The toll either comes as a cost pr Mega Byte of data you put in the wire or as a flat rate agreement with the GPRS provider which limits the amount of data you are allowed to put on the wire within a certain amount of time This is in contrast to traditional LAN WAN where the cost of the infrastructure normally doesn t depend on the amount of data you put on the wire once the infrastructure LAN WAN network is established The IGSS Mitsubishi Ethernet TCP IP driver allows you to set up the driver so that it will minimize the amount of data on the wire and thus minimize the cost associated with using GPRS type networks or other types of toll based networks If you don t care about the toll on data traffic on the GPRS network then you can treat the GPRS network as any other LAN WAN and skip this section Schneider Enable the GPRS connection type You can enable the GPRS connection type for an interface by selecting the
22. uch more efficient than reading the two data registers using two separate read requests