1. USER S MANUAL SWING GATE OPENER SW200 SERIES 1 50m max 1 50m max 100kg max 100kg max Important Safety Advice 1 Knowledge of the relevant electro technical regulations is reguired 2 Training in use and maintenance of safety eguipments is necessary 3 Always lay mains and control cables separately 4 Test every eguipment before initial operation 5 Make familiar with the use of the system before initial operation Content of the Kit a Part A a Actuator x2 Part C PartB x2 The longer one x2 on the pillars The shorter one on the gate x2 Remote Control NG Warning Light x1 3 x1 e Battery Wire Antenna Wire x2 x4 x1 Control Box 1 Wiring Diagram Garden Warning Light Lamp Control Box Min 15cm Ih la A Photocell J Photocell 5 mm aag Instruction of Installation 6b j a 1 Keep a space of 5mm default setting from factory between the driving bolt and the metal cover of the motor 5 amp 2 Measure out the length of E on the figure1 as 36cm or 37 5cm Use this point as a center point for fixing the T form metal Part B on the gate Drill two holes on the gate to fix the Part B the shorter T form metal Copyright SW 200 Version 1 0 Page 1 Recommended Installation Distances Open Range A E 90 15 5cm 36 0
2. cm 100 14 0cm 37 5cm 3 Assembly the Axis for the motor end Part C and the bolt together 4 Put the Actuator onto Part B on the a Es 5 gate Move Part C together with the Pillar Actuator on to pillar to make sure the m a e E gate is complete closed 8 5 Draw a horizontal line from the center point of the Part B Stick the Part C on the pillar and drill the two supposed holes Fix the Part C on the pillar 6 1 Fit the actuator on to the Part B and C 6 2 Fit the release screw of the actuator into the 5th hole on Part B and C Copyright SW 200 Version 1 0 Page 2 Connection Diagram _ Backup battery To transformer 12V AC PHOTOCELL 12V DC Actuator27 7 t Actuator1 Warning Light PHOTOCELL To Backup Batte SENDER RECEIVER NC COM i 1 i 1 1 1 i 1 i ll GN 3 Thermal Fuse to transformer 230V AC 230 VAC in 230 V AC out for Garden Lamp 12 VDC input from main PCB Antenna Ground To external open close switch To external Garden Lamp switch For external LED displa Garden Lamp Manual Button Open close Manual Button Sensor f 12V DC output to small PCB wie ete eee a E a Ground Copyright SW 200 Version 1 0 Page 3 Transformer AC Wir
3. e as remote one key press will open the gate next press to stop next to close the gate next to stop and so on 2 Optional handset or external wall button is available Connected to O C amp GND terminals Manual lamp on Simply switch on and off the lamp by the Manual lamp on key Clear RF memory Press Clear key on the PCB for over 2 seconds while the PCB is on You ll see the LED blinking for 2 5 seconds then the RF memory has been cleared Reset Press Clear key on the PCB and input AC power keep pressing Clear key for over 2 seconds You ll see the LED blink for 2 seconds and light on for 3 seconds then light off Once the mentioned actions have been carried out all RF data will be cleared Quick release Loosen the release screw Copyright SW200 Version 1 0 Page 6 Settings of Dip Switches The default setting of dip switches Function Key No 1 Auto Close Auto Close Timer 60 Sec 30 Sec Gate Type Heavy Gate Light Gate Current Limit selected unselected Approx current limit values for different dip switch setting Maximum Current Limit means also the worst sensibility could shorten the life of motor please try lower current limit first Second Highest Current Limit Minimum Current Limit When user switches several switches on for safety reason system will choose the lowest switch 4instead of switch 6 or 8 current limit setting automatical
4. ight will blink for 3 seconds then Actuator 1 opens 4 seconds later the Actuator 2 opens 2 If the gate hits something Actuators reverse for 3 seconds warning Jight blinks until next command received When closing the gates 1 Warning light will blink for 3 seconds then Actuator 2 closes 4 seconds later the Actuator 1 closes 2 If the gate hits something Actuators reverse for 3 seconds warning light blinks until next command received Lamp control on and off by remote control Simply switch on and off the lamp by the key which had proceeded the RF lamp learning Remark The gate operation works properly only after sucessful Opening Closing Learning Copyright SW 200 Version 1 0 Page 5 6 Photocell Optional 1 During Opening When the loop of photocells has been intercepted system will A ignore if the Actuator 2 has been activated OR B halt if the Actuator 2 hasn t been activated yet 2 During Closing When the loop of photocells has been intercepted system will stop closing the gates and then open both gates simultaneously until the set position Auto close 30 seconds or 60 seconds later only when this function is enabled depends on your setting of key 1 of dip switch warning light will blink for 3 seconds then Actuator 2 closes 4 seconds later Actuator 1 closes When the process finished warning light will be switched off Manual gates control on the PCB 1 The operation is the sam
5. ing Inside of the control box the wiring should be like the photo on the left u A0EZ OV Opening Closing Learning Please proceed this function before using this product otherwise the system will drive the gates improperly E g The gate can t close completely or can t open to the intended degree with some stroke length left unused To activate this function press Auto button on the PCB for 3 seconds while the PCB is on After release the Auto button it will enter the opening closing learning mode as below 1 The system will close the gates first Please remove any obstacle could possibly block the gate Auto Before the actuators start the warning light will blink for 3 seconds Then Actuator 2 will close first and then Actuator close 1 second later 2 After 3 seconds Actuator 1 will open the gate 1 fully waiting for 3 seconds Actuator 2 will open the other gate 2 fully 3 After 3 seconds Actuator 2 will close fuly first waiting for 3 seconds Actuator 1 will close fully 4 System repeats the actions of point 2 and 3 one more time 5 After 3 seconds system checks operation of Actuator 1 and Actuator 2 together 6 After learning process succeeded the system is ready for use If the system blinks after this learning mode which means learning in vain please make sure that there s no obstacle on the way then try again to trigger the learning mode Copyright SW 200 Version 1 0 Page 4 5 Rem
6. ly Version 1 0 Page 7 Optional Accessories Operation of Photocell Select a proper installation site where the sender and receiver can be along the same line and at the same height Connect to the opener s PCB as wiring diagram above Power on the system try and see if it works properly by interruptting the IR between the sender and receiver fortimes The relay in the receiver should respond accordingly while LED switches ON and OFF With photocell well installed while it s triggered during opening the gates the gates will ignore the interruption and open While it s triggered during closing the gates the gates will reverse for 3 seconds and stop and warming light will keep blinking untill next command sent Specifications Model SW200 Power Supply 230V AC 10 50Hz 110V AC 60Hz available Power for Motor 12VDC Maximum Gate Weight 200KGS 100 100KGS Maximum Gate Width 1 5M 1 5M 10Feet Stroke Length 330mm 13in Drive ACME 90 Operating Time around 15 Sec Open Range 110 Max Duty Cycle 20 Operation Temperature 20 65 C Overload Protection Yes Backup Recharging Battery Foundation Yes Not Including Battery 12V 7AH im Auto Gate Close a Adjustable timer off 30 60sec fa Extension Terminal Warning Light Photocell Back up Battery RF Carriage 315 MHz 433 92 MHz Control Range Approx 30 50 Meters Copy
7. ote Learning activation of remote control for gate and lamp operation To activate the remote control service please proceed the following steps A RF gate learning for Open Close the Gates 1 Press RF key on the PCB for over 2 seconds while the PCB is on 2 You ll see the LED light on learning mode entered please press any key on the remote control LED will now blink for 3 times learning succeeded or light off after 10 seconds without blinking learning failed please try again the whole process 3 Please repeat the step 1 and 2 to activate another remote control otherwise the unlearnt remote control won t be recognized by the system B RF lamp learning for Turning On Off the Garden Lamp Proceed with RF lamp key on the PCB and another key on the remote control as step 1 3 above Note Up to 8 different RF remote control keys can be learnt for each function by this system gates amp Garden Lamp Remote Control Choose two of the four keys to proceed RF learning The rest of the keys are available for other purposes such as Garage Door Opener The remote control has 4 keys on it and choose two of them to proceed RF learning for one key gate control and lamp control separately Operation open close and stop by remote control The remote operation is very simple one key press will open the gate next press to stop next to close the gate next to stop and so on When opening the gates 1 Warning l