1. Mew Module 2 Edit the settings of the new Generic Ethernet Module As shown in the screen shot Type ener ty E ee ee below the module was named HD67660 and the IP address assigned is 192 168 0 5 Vendor Allen Bradley ase A For the Comm Format Data SINT shall be selected as the data type B Assembly Description Instance E Input 101 Bbi The HD67660 A1 can uses up to 244 bytes for input assembly instance 101 and 244 Output 100 oi bytes for output assembly instance 100 Comm Format Data SINT m T METTE 4 bi UE A no o 5 RSLogix 5000 requires a configuration assembly instance Both modules do not provide a Pree configuration assembly instance Therefore it is allowed to select an instance of 3 and to Bee set the value to zero v Open Module Properties 3 The setting of 10msec for the Requested Packet Interval RPI is adequate but it Module Properties LocalENB ETHERNET MODULE 1 1 is possible to change this value as required A lower value of 2ms shall not be selected General Connection Module Info Requested Packet Interval RPI 10 0 ms 1 0 3200 0 ms C Inhibit Module Warning A The field Use Unicast Connection over EtherNet IP must be checked Major Fault On Controller If Connection Fails While in Run Mode Use Unicast Connection over EtherNet IP Module Fault Status Running ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb
2. IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 11 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67660 To configure the Converter use the available software that runs with Windows called SW67660 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67660 the window below appears Fig 2 HA Note It is necessary to have installed Net Framework 4 Hl ADFweb com Compositor SW67660 PROFINET EtherNet P Slave 5W6 660 PROFINET EtherNet IP Slave Converter Jpened Configuration af the Converter Begin Step 1 3 Mew Configuration ar Open Configuration Step 2 gt Set Communication ay E PROFINET XML Step 4 3 Update Device www ADFweb com Figure 2 Main window for SW67660 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 12 of 30 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration SW67660
3. com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 22 of 30 Industrial Electronic Devices 4 After the configuration is completed the controller tags are created d RSLogix 5000 ESEMPIO B165 1769 L23E QB1 19 11 Controller Tags ESEMPIO B165 controller i File Edit View Search Logic Communications Tools Window Help mx as S amp X BA ES eo cv Imi Ga amp T L amp amp rm 9 Rem Run T noe m Pa mE No Forces gt IS Controller OK m No Edits al bs dein T b aS antroller Organizer X xij Scope TE B165 cm Show me ags ie i n 2 J 2 3 Controller ESEMPIO B165 i i 4 Name zafj Value Force Mask Style Data Type Description Constant itl E Ig GS Controller Fault Handler HD67599 1 ses Decimal SINT S00 ne xe E Power Up Handler HDB758 0 Decimal SINT g 5 Tasks HD D Decimal SINT ilz 5 48 MainTask mHDS 59 0 Decimal SINT 2 He cope BiHb5 53 0 Decimal SINT CI Unscheduled Programs ors rl el pos E Motion Groups HDE753 0 Decimal SINT EI Ungrouped Axes E HD6759 0 Decimal SINT C Add On Instructions mHDsg59 0 Decimal SINT Cg he mera o Decinal SINT i a soak HD6759 0 Decimal SINT S Add On Defined HD6753 0 Decimal SINT 4 Predefined HD6758 0 Dec
4. slowly 0 5Hz update in progress Ledi Led2 Led3 Led4 Led5 Led6 Green Yellow Red Red Green Green ON MT BF SF Etherneti Tx Ethernet2 Tx amv n 6 Ethernet2 Tx green Blinks when is transmitting Ethernet frames ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 10 of 30 AL Industrial Electronic Devices ETHERNET IP The Ethernet connection must be made using Connector3 or Connector4 of HD67660 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable Connector4 Ethernet2 port RJ45 Plug Connector3 Etherneti port RJ45 Plug PROFINET The PROFINET connection must be made using Connector3 or Connector4 of HD67660 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable ADFweb com Srl
5. 9 0 Decimal SINT HD6759 0 Decimal SINT HD5753 0 Decimal SINT m 4 gt Monitor Tags AEditTags Ff de L u Add Branch E ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 23 of 30 Industrial Electronic Devices i RSLinx Classic Lite RSWho 1 JEU ES 5 With RSLinks Classic Lite after have done a at File view Communications Station DDE OPC Security Window Help network Scan RSWho and finding the EtherNet IP device amp 8 it is possible to load the EDS file for the device in order to Iv Autobrowse efres j Browsing node 192 168 1 20 found have the Module Info compiled Workstation FEDERICO 9 Hx Linx Gateways Ethernet ud f wg AB ETHIP 1 Ethernet 192 168 1 10 192 168 1 192 168 1 192 168 1 192 168 1 10 1769 L23E QB1 Ethernet Port 1769 L23E QB1 Ethernet Port 17690 L23E HD67595 HD67590 HD67599 P 192 168 1 122 Unrecognized Device HD67595 Module Properties LocalENB ETHERNET MODULE 1 1 E3 A grrrreereerereeereerennenneneneneerennnnennnnnnnnerenenertenennenneenennnenernneennnnrnr TU i ade d 92168 1 189 HD67599 HD67899 o ye 192 168 1 20 1734 AENT EtherNet 192 168 1 20 1734 AENT Identification Status Vendor Major Fault Product T ype Minor Fault Product Code Internal St
6. Create New Configuration Name of the new Configuration Kee A device s configuration can also be imported or exported b Open Configuration To clone the configurations of a programmable PROFINET EtherNet IP Slave Converter in order to configure another device in the same manner it is necessary SW6 7660 to maintain the folder and all its contents Open an Existing Configuration To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the jme button Open Configuration Example Example3 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 13 of 30 Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the Bi Software Options software SW67660 Software Options Selected Language English English EB Software Options SATA Language Connection Options V Enable Internet Connection Check Software Update at Start of Program Check Available Update In the section Connec
7. Global libraries gt Telaio di montagg SIEMENS v j TEst HD67606 lli Add new device sis Devices amp networks P ig PLC 1 CPU 1212C AC DC RIy gt gj Common data gt E Documentation settings v Languages amp resources zl Project texts ill Go online Pd Go offline A R Im x maiuppest paskagesmm mmm mmu u EVI il Ie T ETETETT _ Project languages m b og Online access b E SIMATIC Card Reader Device overview Y Module Slot Install general station description file Installation result 1 Message eo Installation was completed successfully ADFweb com Srl IT31010 Mareno Treviso address Qaddress The CM 1243 5 PROFIBUS interface X1 CPU 1212C ACIDCIRIy n rio inm esc i Info af GQ Properties m Topology view lY Device view Install general station description file ieee 1 27 Installation of GSD files The installation may take some time Totally Integrated Automation PORTAL E D lla j a 9 v Catalog E Search drip it o fu Filter s gt ig CPU amp gt gi Signal board gt ig Communications boards 4 gt ig DI c iv b mm na Source path C Users FedericolDesktop Content of imported path iex mmm a ee mmm mmm a mum mm Sj mmm ess mmm Hem peux ee mmm vi File Version Langua
8. IN Rail mounting Device Family HD67660 PROFINET Ethernet IP Slave Converter Order Code HD67660 A1 PROFINET Ethernet IP Slave Converter ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 20 of 30 Industrial Electronic Devices PLC CONFIGURATION for EtherNet IP The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from another supplier please attend to the associated documentation These are the steps to follow under the Ethernet section in the I O Configuration tree viu 1 Creat pO T T Ce Ic BALA Eee D C LT og An f L RSLoc 5000 MPIO B ea Gen m PAAR eric Ethernet Module File Edit View Search Logic Communications Tools Window Help Bak 9 56 v ORD B Y amp QQ serar a No Forces F OK 4 1 T M l No Edits pa 4 B RSLopix 5000 ESEMPIO B165 1769 L23E OB1 19 11 Eel File Edt View Search Logic Communicat
9. User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 1 of 30 Industrial Electronic Devices User Manual EUN Revision 1 000 T MESE English i4 ser caat d il PROFINET PROFIBUS Nate Cove PROFINET EtherNet IP Slave Converter SEM MAHA g Order Code HD67660 A1 T e cum ia 3 o un RE Serali E3 for Website information A http www adfweb com Product HD67660 L for Price information gt http www adfweb com Price HD67660 A1 7 Benefits and Main Features m For others PROFINET devices see also the following links Triple electrical isolation PROFINET from to Two Ethernet ports www adfweb com Product HD67078 M Bus Master www adfweb com Product HD67601 Serial Temperature range 40 C 85 C 40 F 185 F www adfweb com Product HD67602 Modbus Master www adfweb com Product HD67603 Modbus Slave www adfweb com Product HD67606 CAN www adfweb com Product HD67607 CANopen www adfweb com Product HD67608 www adfweb com Product HD67609 www adfweb com Product HD67610 www adfweb com Product HD67611 www adfweb com Product HD67612 DeviceNet Master DeviceNet Slave J1939 Modbus TCP Client Modbus TCP Server ON NN NN BONN ON ON NN ON NN Do you have an your customer protocol See the following links www adfweb com Product HD67003 Do you need to choose a device do yo
10. ad software to device Consistent download e gt Additional inform There are differences between the settings for the project and the se 4 Overwrite all ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 29 of 30 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document content is a recurring audit For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate collection systems mus his symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and human health w
11. ate Revision Configured Serial Number Owned Product Name Module Identity Driver Diagnostics Configure Driver Upload EDS file From device Security Device Properties For Help press F1 NUM 12 12 12 03 30PM 4 J Reset Module Status Offline Identification Status Vendor Major Fault None Product Type Communications Adapter Minor Fault None Product Code 599 Unknown Internal State 1680055 unknown Revision Jar Configured Yes Serial Number E2071B24 Owned Yes Product Name HD67599 Module Identity Mismatch Reset Module ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices PLC CONFIGURATION for PROFINET User Manual Document code MN67660_ENG PROFINET EtherNet IP Slave Revision 1 000 Page 24 of 30 The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11 software by Siemens In the case of using a control system from another supplier refer to attend to the associated documentation These are the steps to follow 1 Install the description file of the module TA Siemens TEst_HD6 606 Project Edit View Insert Online Options Tools Window Help GERD EJ Save project Sh M 38 Y Settings Devices 00 Install general station description file GSD Shei X CU
12. cifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is danger for people to serious injury or death and or the A possibility of damage CE CONFORMITY The declaration is made by us You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 EXAMPLE OF CONNECTION EtherNet IP Ethernet IP network mace PROFINET network u aa 11 A HD67660 A1 Internet PROFINET network Integrated Switch Ethernet IP network HD67660 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices CONNECTION SCHEME Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode LI Normal In Boot User Manual Document c
13. correctly updated Read Firmware when finish Project Read Project when finish Execute update firmware INIT Waiting Ver 1 001 z FIRMWARE Waiting Figure 4 Update device windows PROJECT Waiting ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 17 of 30 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update L Note When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67660 device ax LN assistance L d L s Note When you receive the device for the first time you also have to update the Firmware in the HD67660 device Warning If Fig 5 appears when you try to do the Update try these points before seeking Bl 5w67660 Ethernet Update Try to repeat the op
14. erations for the update INIT PROTECTION Try with another PC Try to restart the PC If you are using the program inside a Virtual Machine try to use it in the main Operating System If you are using Windows Seven or Vista or 8 make sure that you have the administrator privileges Pay attention to the Firewall lock Figure 5 Protection window Check the LAN settings FIRMWARE PROTECTION PROJECT PROTECTION A In the case of HD67660 you have to use the software SW67660 www adfweb com download filefold SW67660 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Ver 1 001 Web User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 18 of 30 Industrial Electronic Devices k MECHANICAL DIMENSIONS 9 O E N om Ee e EE 58 g SN To f iiz 2 e 23 mm 120 mm 4 72 inch 0 9 inch Housing PVC Weight 200g Approx Figure 6 Mechanical dimensions scheme for HD67660 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 19 of 30 Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67660 A1 Lo Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm D
15. ge Status Info Ir GSDML V2 25 ADFweb HD67604 20121221 xml V2 25 English Not yet installed ADFweb Gateways Remaining time in seconds 27 Phone 39 0438 30 91 31 INFO www adfweb com User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 25 of 30 Industrial Electronic Devices 2 Press the Devices and networks button 1 from the right drop down menu under Other field devices PROFINET IO Gateway ADFWEB com HD67660 double click on Serial module 2 Note kK If you have installed more than one xml file go to the Information section and in the Version field select the correct xml file 3 before double clicking on Serial module TA Siemens Guide Project Edit View Insert Online Options Tools Window Help Totally Integrated Automation GE Gd seveproject BY 33 2 X SEM uw nom BR 3 coonline cootfiine Ao IR IR X 3 I ORTAL Il Device view Options Guide Devices amp networks m Topology view g Network view rk Network i Connections S7 connection E d Fl Qs 100 Ie zr Devices 00 v Guide lli Add new device boje3e asempsey E Filter ff Devices amp networks PLC 1 SERIAL a T gt m PLC a C ACIDCIRIy CPU 1212C CAN DP NORM gt om nic gt Unassigned devices Notassigned i i Gateway gt gd Common data gt i Sieme
16. he number of output byte of the slave station The means of the fields for EtherNet IP are a ADFweb com Srl IT31010 Mareno Treviso In the field IP ADDRESS insert the IP address that you want to give to the Converter for the EtherNet IP side In the fields SUBNET Mask insert the SubNet Mask for the EtherNet IP side In the fields GATEWAY insert the default gateway that you want to use for the EtherNet IP side This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for EtherNet IP communication is defined The port has a fixed value of 44818 PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 14 of 30 E Set Communication FP SW67660 Set Communication Setting PROFINET IP ADDRESS SUBNET Mask 255 4208 GATEWAY 192 158 Port 34964 PROFIMET Name of Station devicenamel Number Byte IN Number Byte Qut EtherNet IP IP ADDRESS SUBNET Mask 255 255 F GATEWAY ag ok X Cancel Figure 3 Set Communication window INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 15 of 30 Industrial Electronic Devices PROFINET XML By pressing the PROFINET XML button it is possible to save the xml file for the PROFINET side With this feature y
17. hich could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 3 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 30 of 30 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address pr
18. igital Output by double click on the three items in this order Module 3 Submodule 1 4 Submodule 2 5 TA Siemens Guide Project Edit View Insert Online Options Tools Window Help Totally Integrated Automation F Ed seveprject zm XM os os X 2 Bo EG BE 3 coonline g Goofin A IR IR X 4 I PORTAL M PLC_1 CPU 1212C AGDORIy gt Distributed O PROFINET IO System 100 PN IE_1 gt guide W mi X Devices Topology view h Network view Device view OO ER dt guide e 23 Options 3 H Qe liom x v Guide lli Add new device nh Devices amp networks gt gj PLC_1 CPU 1212C ACIDCIRIy gt gj Common data b E Documentation settings fojeye gt a1empjeH m Submodule 1 b te Languages amp resources 7 gt ou Online access b ig SIMATIC Card Reader Device overview 00 BUILD c Y Module Rack Slot laddress Q address Type Order no guide 0 0 CAN HD67606 A1 bod 0 0 Inter SERIAL 0 1 v Module 1 0 2 Module 12346 0040 M Submodule 1 0 22 68 82 Submodule 1 12345 0040 51 23 64 88 Submodule 2 12345 0040 52 Submodule 2 0 0 3 v Information info Gj 9 Diagnostics i Properties General Orderno 12345 0040 52 v General l Version a General ersion Catalog
19. imal SINT Eh Module Defined E HD6759 0 Decimal SINT lm ie PN HDE753 0 Decimal SINT 7 CompactLogix5323E QB1 System Seances Ben SINT fa 1769 L23E QB1 ESEMPIO_B165 HD5753 0 Decimal SINT 1769 L23E QB1 Ethernet Port LocalENB p HD6759 0 Decimal SINT Bs Ethernet HDE 753 0 Decimal SINT 1769 L23E QB1 Ethernet Port Loce HD57583 0 Decimal SINT Wa eee E HD6759 0 Decimal SINT amp PointIO 5 Slot Chassis fj 0 1734 AENT A io vari HD5758 0 Decimal SINT 1 1734 084 C output di HD6759 0 Decimal SINT 2 1734 IB4 C input dig HD6753 0 Decimal SINT 3 1734 1E2v C inputan 4 HDB759 o Decimal SINT J 4 1734 082v C output alj d yp 6789 0 Decimal SINT E LEE UE inis HD6758 0 Decimal SINT 5 Embedded I O HD6759 0 Decimal SINT B 1 Embedded IQ16F Discrete Inp HD6759 Decimal SINT B 2 Embedded OB16 Discrete Outg HDB758 0 Decimal SINT Expansion I O HDe759 0 Decimal SINT HD6759 0 Decimal SINT HDB758 o Decimal SINT HDB753 0 Decimal SINT HD6753 0 Decimal SINT HDE75S 0 Decimal SINT HD6753 0 Decimal SINT HD6753 0 Decimal SINT HDE75S 0 Decimal SINT HD6759 0 Decimal SINT HHD6759 0 Decimal SINT HD6758 0 Decimal SINT HD6759 0 Decimal SINT HDE75S 0 Decimal SINT HDE759 0 Decimal SINT HDB758 0 Decimal SINT HD675
20. inf _ n gt PROFINETinte Description Identification p AN a A Description of submodule 2 gt Details view nel LL D 4 Portal view ry SERIAL V Project Guide opened ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 28 of 30 Industrial Electronic Devices 5 Load the configuration into the PLC Extended download to device Configured access nodes of PLC 1 Device Device type Type Address Subnet PLC 1 CPU 1212C ACID PNIIE 192 168 2 50 PNIIE_1 CM 1243 5 CM 1243 5 PROFIBUS 2 Type ofthe PG PC interface LJ PN IE v PGIPC interface E Broadcom NetLink TM G w gi Connection to subnet PNIIE 1 O istgateway e Accessible devices in target subnet Show all accessible devices Device Device type Type Address Target device PLC 1 CPU 1212C ACID PN IE 192 168 2 50 PLC 1 PN IE Access address Load preview Q m Status Target Message Action Mi OQ rci Ready for loading Flash LED e gt Stop modules All modules will be stopped for downloading to device Stop all Online status information e b Device configurati Delete and replace system data in target Download to device g Connected to address 192 168 2 50 x KA Scanning ended e gt Software Downlo
21. ions Tools Window Help ETETEES Easue oe L v4A5t3 YR AA eers 9 Lun be Eo Dmae D Ean MN RH on EEE A gt asks FoK 1 E nee EA MainTask No Forces b E BAT MED NN E39 Unscheduled Programs No Edits e Evo sb dre E shir rer ate oe 307 p ERE Motion Groups i l Favorites Satety Alarms j Timer ci E Ungrouped Axes E Add On Instructions Controller Organizer c 3 Data Types C2 Controller ESEMPIO B165 ig Ep User Defined S E Tasks w Strings E o aA ManTask ER Add On Defined a E Unscheduled Programs amp E Predefined B E Motion Groups t gi Module Defined 3 Ungrouped Axes t Gi Trends e 3l Add On Instructions 1783 EMS08T 1783 EMSO8T Ethernet Managed Switch Allen Bradley a a Io Configuration 2 3 Data Types 1783 ETAP 3 Port Ethernet Tap Twisted Pair Media Allen Bradley S E CompactLogix5323E QB1 System 0 Eg User Defined 0 1783 ETAP1F 3 Port Ethernet Tap 1 Fiber 2 Twisted Pair Media Allen Bradley ff 1769 123E QB1 ESEMPIO B165 a jj Strings 0 1783 ETAP2F 3 Port Ethernet Tap 2 Fiber 1 Twisted Pair Media Allen Bradley E 1769 L23E QB1 Ethernet Port LocalENB ER Add On Defined 1788 ENZDN A 1788 Ethernet to DeviceNet Linking Device Allen Bradley ae y IINE g Eih Predefined 1788 ENBT A 1788 10 100 Mbps Ethernet Bridge Twisted Pair Media Allen Bradley w Oj Module Defined 1 788 EWEBIA 1788 10 100 Mbps Ethernet Bridge w Enhanced Web Serv Allen Bradley E T
22. mation gt Save project a X E J xX EA E42 ii fui m f ra iX Go online Id Go offline A IR m x 1 PORTAL Guide Devices amp networks EE M D Topology view Network view I IO system PLC 1 PROFINET IO System 100 Devices OO Guide lli Add new device sh Devices amp networks gt gli PLC 1 CPU 1212C AC DCIRly gt ad Common data b E Documentation settings PLC 1 CPU 1212C boje3e e1empaeH E d F Languages amp resources gt Online access b mg SIMATIC Card Reader 00 auiu Network overview v Device Type Address in subnet Subnet Master system Comment w SIMATIC 1200 station 1 SIMATIC 1200 station gt PLC 1 CPU 1212C ACIDCIRIy v GSD device 1 GSD device b SERIAL CAN i Properties 7 Info j Diagnostics General General vw Use IP protocol Ethernet addres e SetlP address in the project b Advanced options saueiqr E IP address Portal view Project Guide opened ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 27 of 30 Industrial Electronic Devices 4 Then double click on the Serial label 1 and in the field name change it accordingly to the name defined in the Compositor SW67660 2 Then add the main module Module and the sub modules of Digital Input and D
23. n the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Code on the label on the product and download the updated from our web site www adfweb com download REVISION LIST Revision Date Author Chapter Description 1 000 13 03 2014 Ff All First release version WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device are required for each individual application legal and safety regulation The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the spe
24. ns AG P j Documentation settings v jg ADFweb com fi gt ig HD67078 gt i Languages amp resources zur 3 m gt gj Online access ul amp gt ig HD6707882 gt 59 SIMATIC Card Reader N i gt ig HD67602 S etwork overview onnections ig HD67603 Wu Device Type Address in subnet Subnet Master system Comr d E HD67604 SIMATIC 1200 station 1 SIMATIC 1200 station gt ig HD6760421 gt PLC 1 CPU 1212C ACIDCIRIy gt ig HD67605 v GSD device 1 GSD device ror f 14 c Isa E lt T A Properties im Info i Y Diagnostics gt ig HD67609 A1 m HD67679 General General General Order no HD67606 A1 Name GSD device 1 Author Utente Description Comment Profinet CAN Adapter 4 Portal view Project Guide opened ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 26 of 30 Industrial Electronic Devices 3 Connect the PLC to the HD67660 module by drawing the Ethernet wire between the two Ethernet ports Then assign the IP Address 1 defined in the Compositor SW67660 to the HD67660 Then double click the Module 2 TA Siemens Guide w N Project Edit View Insert Online Options Tools Window Help Totally Integrated Auto
25. ode MN67660 ENG V OV CILEDE ON Power Supply O LED2 MT 8 24V AC or EXER 12 35V DC O LED4 SF et PROFINET EtherNet IP Converter O LEDS Not used see Hh HD67660 A1 oo www ADFweb com oHS L1 LED6 Not used Q n ue Eth t Dip Switch A E 2 s Date Code c s MAC 10 64 E2 07 22 7C B176 Serial Nr B8529 Figure 1 Connection scheme for HD67660 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com PROFINET EtherNet IP Slave Revision 1 000 Page 5 of 30 Connector3 Etherneti port Ethernet2 Tx Connector4 Ethernet2 port RJ45 Plug Connector1 Power Supply port OV Ground V Positive wire V AC min 8V max 24V V DC min 12V max 35V Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 6 of 30 Industrial Electronic Devices CHARACTERISTICS The HD67660 A1 is a PROFINET EtherNet IP Converter It allows the following characteristics Up to 500 bytes in reading and 500 bytes in writing on EtherNet IP side Two directional information between EtherNet IP and PROFINET Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 CONFIGURATION You need Compositor SW67660 software on your PC in order to perform the following Define the parameter of the PROFINET Define the parame
26. ou can save the configuration of the converter of the PROFINET side Note e When you import the xml file on your PROFINET you have to add the main module and all the submodules present in it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 16 of 30 Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary SW6 7 7660 Update Firmware from Etherner UDP If you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A in ON position Turn on the device Connect the Ethernet cable Check the Connection the device Insert the IP 192 168 2 205 Eee m Press the Ping button Device Found must appear Press the Next button J Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device SGWO 660 Put Dip2 of Dip Switch A in OFF position Update Firmware from Etherner UDP Turn on the device 2 205 Update Firmware from Etherner UDP Update Device Options ly Firmware At this point the configuration firmware on the device is
27. ovided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67181 CAN bus Repeater www adfweb com product HD67181 HD67316 CAN bus Analyzer www adfweb com product HD67316 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
28. rends 0 1794 AENT 1794 10 100 Mbps Ethernet Adapter Twisted Pair Media Allen Bradley 5 6 Jo Configuration Drivelogix5730 Et 10 100 Mbps Ethernet Port on DriveLogix5730 Allen Bradley 88 CompactLogix5323E QB1 System ETHERNET BR ic Eth P CIP Bridge C j f 1769 L23E QB1 ESEMPIO Bi65 ERE E ums RUD LP E 2 1734 184 C input dio 1769 L23E QB1 Ethernet Port LocalENB EtherNet IP SoftLogixS800 EtherNet IP Allen Bradley 3 1734 1E2V C input an ciam Ethernet PSSCENA Ethernet Adapter Twisted Pair Media Parker Hannif v 4 1734 0E2VC output 4 1769 L23E QB1 Ethernet Port Loce g ETHERNET MODULE HD67599 g 1734 AENT A io vari 9 CompactBus Local 2 489 PointIO 5 Slot Chassis _Add Favorite S Embedded 1 0 0 1734 AENT A io vari 1 Embedded IQ16F Discrete Inp D 1 1734 084 C output dic By Category By Vendor Favorites 2 Embedded OB16 Discrete Outr f 2 1734 184 C input dia ca oma 10 E rer 4 1734 0E2V C output Li 3j ETHERNET MODULE HD67599 Efl CompactBus Local amp j Embedded 1 0 be g 1 Embedded IQ16F Discrete Inpt S 2 Embedded 0816 Discrete Outr 73 Expansion I O Create a module Ready ADFweb com Srl IT31 010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 21 of 30 Industrial Electronic Devices
29. ter of the Ethernet IP ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 7 of 30 AL Industrial Electronic Devices POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below en Consumption at 24V DC owie wma A Caution Not reverse the polarity power OV Ground _ P B V Positive wire V AC min 8V max 24V OV V V DC min 12V max 35V HD67660 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET EtherNet IP Slave Document code MN67660 ENG Revision 1 000 Page 8 of 30 AL Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip2 of Dip Switch B The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Project Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dipi Must be at ON I Dip2 Functioning Mode I i c I ADFweb com Srl IT31010 Mareno Treviso INFO w
30. tion Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67660 check automatically if there are updatings when it is launched ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of two buses PROFINET and EtherNet IP By Pressing the Set Communication button from the main window for SW67660 Fig 2 the window Set Communication appears Fig 3 The means of the fields for PROFINET are Lal In the field IP ADDRESS insert the IP address that you want to give to the Converter for the PROFINET side In the fields SUBNET Mask insert the SubNet Mask for the PROFINET side In the fields GATEWAY insert the default gateway that you want to use for the PROFINET side This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for PROFINET communication is defined The port has a fixed value of 34964 In the field PROFINET Name of Station is possible to assign a name to the PROFINET node In the fields Number Byte IN insert the number of input byte of the slave station In the fields Number Byte Out insert t
31. u want help Ask it to the following link User Manual www adfweb com Cmd helpme ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLE OF CONNECTION CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS ETHERNET IP PROFINET USE OF COMPOSITOR SW67660 NEW PROJECT OPEN PROJECT SOFTWARE OPTIONS SET COMMUNICATION PROFINET XML UPDATE DEVICE MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES PLC CONFIGURATION for EtherNet IP PLC CONFIGURATION for PROFINET DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso D ODNADUAWNNNNNGA User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 2 of 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click o
32. ww adfweb com Phone 39 0438 30 91 31 AL User Manual PROFINET EtherNet IP Slave Document code MN67660_ENG Revision 1 000 Page 9 of 30 Industrial Electronic Devices LEDS The device has got six LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 ON supply voltage ON Device powered ON Device powered green OFF Device not powered OFF Device not powered ON Device not able to communicate with the Master DeviceNet OFF No maintenance are present Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 MT maintenance display yellow ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times in the network no 3 BF bus fault red IP address has been set Flashing At least one configured AR is no longer in the data exchange OFF No errors are present Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress ON At least one AR is not in the data exchange Blinks quickly Boot state OFF No errors are present Blinks very slowly 0 5Hz update in progress eae Blinks quickly Boot state 5 Ethernet1 Tx green Blinks when is transmitting Ethernet frames Blinks very slowly 0 5Hz update in progress 4 SF group error red Blinks quickly Boot state Blinks very