CN2HK LIMITED Complete Wireless Home Alarm Security System
Contents
1. or PT22620 is high electric level marked by H the 12 pins in the row near the side of the electric circuit board is low electric level marked by L the 12 pins in the middle row is to be set by short jumper slip if a pin in the middle row is connected by a short jumper slip to the row pin we called the pin encoded as 1 if a pin in the middle row is connected by a short jumper slip to L row pin we called the pin encoded as 2 if a pin in the middle row is not connected by a short jumper slip or in float state we called the pin encoded as 0 the 8 pins in the middle row for address code has three encoding state 1 0 2 The 4 pins in the middle row for zone code has only two encoding state 1 2 that is say the 4 bit zone code has no float state 0 Fig 6 illustration diagram of infrared detector encoding BISS0001 9V BATTERY A1A2A3A4A5A6A7A POWER SWITCH HBITADDRESSCODE 4 BIT DATA CODE FOOR SETTING ZONE P 10 Fig 7 illustration diagram of door entry detector encoding antena a e a C2262 A0A1A2A3A4A5A6A7A8D0D1D2D3 12V BATTERY eH a N a L 0 2 8 BIT ADDRESS CODE 4 BIT DATA CODE FOOR SETTING ZONE tz m Fig 9 the 8 bit address code in the middle row all in float state 0 the zone code is 2211 zone 1 gg ram Fig 10 the 8 bit address code in the middle row
2. all in float state 0 the zone code is 2121 zone 2 THREE UE Fig 11 the 8 bit address code in the middle row all in float state 0 the zone code is 2112 zone 3 11 ram poses Fig 12 the 8 bit address code in the middle row all in float state 0 the zone code is 2111 zone 4 1 0 2 NA 24 Hours zone code emergency code 1 ON us 2 L sp Fig 13 the 8 bit address code in the middle row all in float state 0 the zone code is set as 2212 that is 24 hours guard zone or emergency zone used for wireless emergency button or for smoke detectors gas leakage detectors oH eel B mega s address code zone 1 code Fig 14 the 8 bit address code in the middle row is set as 21120102 the zone code is 2211 zone 1 B 1110027222 121 address code zone 2 code Fig 15 the 8 bit address code in the middle row is set as 11100222 the zone code is 2121 zone 2 P 12 122802914121712 e T s onis T Los address code zone 3 code Fig 16 the 8 bit address code in the middle row is set as 12202011 the zone code is 2112 7 3 2 t eise e 2221201 LZILL2 lus c nio a address code zone 3 code Fig 17 the 8 bit address code in the middle row is set as 22212011 the zone code is 2112 zone 3 See T od
3. around the alarm set but the monitor time is only lasted for 20 seconds when you press the key 7 one time If you want to continue listen to the sound around the alarm set you have to press the key 7 again on your caller telephone alarm receive telephone not more than 20 seconds interval If you don t withdraw guard when you received the alarm the alarm set will dial the pre stored next group telephone numbers consecutively P 6 Please remember it will take 30 seconds time to play the pre stored messages each time while auto dial each group of alarm telephone INSTALLATION AND USE GUIDE Telecommunication operation by telephone If you need to operate the alarm system far away you can dial the alarm by any other telephone far or near after five times ring sound the alarm system will automatically hook off and prepare to process the command you give out from the caller telephone you have to input four digit telecommunication operation user password its initial value is 1234 and you can modify it by yourself on your caller phone at first then you can set the alarm system by input digit number as command on the telephone you used Press 1 setting guard of the alarm system Press 2 withdraw guard of the alarm system Press 3 setting alarm with sound Press 4 setting alarm with no sound Press 5 startup the siren Press 6 shut off the siren Press 7 open background sound
4. its detection angle to best position The following aspect should be noted 1 the infrared detector may not direct to outward window 2 obstacle on its front have negative effect 3 more than two infrared detectors should not installed on the same area P7 4 strong wind flow fire radiator should be avoided for it may trig wrong alarm message 5 when the infrared detector powered up it will take five minutes to adapt itself to working mode 6 infrared detector can only used in closed room not used in open ground Door entry detector magnetic switch amp emitter installation and use 1 The emitter of door entry detector is mounted on the edge of moveable door and the magnetic bar is mounted on the fixed doorframe The two pieces of devices must be not more than 1cm distance when the door closed 2 The magnetic bar must be installed near to the emitter side of LED indicator 8 ENCODING METHOD Encoding and decoding method of the wireless alarm system This alarm system use wireless transmission style to communicate with its wireless detectors To protect each alarm system from interfering each other the wireless signal can use different encoding style for different alarm system you can add detector to an alarm system by encode the detector Each alarm system has itd unique wireless communication code this include 8 bit address code A0 A1 A2 A3 A4 A5 A6 A7 and 4 bit zone code or date code DO D1 D2 D3 each set of alarm sy
5. monitor Press 8 close background sound monitor Press 9 exit telecommunications settings and hook on Press 01 open guard zone one alarm reporting Press 02 close guard zone one alarm reporting Press 03 open guard zone two alarm reporting Press 04 close guard zone two alarm reporting Press 05 open guard zone three alarm reporting Press 06 close guard zone three alarm reporting Press 07 open guard zone four alarm reporting Press 08 close guard zone four alarm reporting If no key input more than ten seconds the alarm system auto dial will hook on and exit telecommunication setting automatically If you press key 7 on your caller telephone you can monitor the sound given out around the alarm set but the monitor time is only lasted for 20 seconds when you press the key 7 one time If you want to continue to listen to the sound near the alarm set you have to press the key 7 again on your caller telephone not more than 20 seconds interval Installation and use guide Infrared detector installation and use Open the power switch on the side of the detector at first Mounting height is adjusted to 2 2m or so Mounted on the corner of the room is preferable and its detecting direction perpendicular to people walking direction will have best effect Mounting method take out the bracket in the accessories and fix it on your wall fix the detector to the bracket and adjust
6. 1 4 Each of the four guard zone can be opened or closed independently by input digit key on the keypad as follows Open guard zone 1 press four digit password first then press set 1 Close guard zone 1 press four digit password first then press set 2 Open guard zone 2 press four digit password first then press set 3 Close guard zone 2 press four digit password first then press set 4 Open guard zone 3 press four digit password first then press set 5 Close guard zone 3 press four digit password first then press set 6 Open guard zone 4 press four digit password first then press set 7 Close guard zone 4 press four digit password first then press set 8 If a guard zone is set closed the detectors of the zone will not trig any alarm even in guard setting status Emergency alarm function When met emergency event you can press the panic key the system will immediately put into emergency alarm state if you press the panic key the remote controller the system s siren will give out loud sound as well as dial out pre stored telephone numbers and if you press the panic key S on the remote controller the system s siren will not give out sound but dial out the pre stored telephone numbers as well There is also a panic key on the forward side of the alarm main set Alarm System setting method 1 Store alarm telephone number Press key on the keypad as follows Four digit user password store
7. CN2HK LIMITED Complete Wireless Home Alarm Security System CK 8806 User Manual Please read this manual before operating this product ENG After you finish reading this manual store it in a safe place for future reference MAIN FUNCTION AND FEATURES DC 9V power supply standby current less than 20mA Six groups of alarm telephone numbers can be pre stored Ten seconds pre recorded memo messages AU Ne Long distance via public telephone network set guard status or withdraw guard to the main dialer Long distance via public telephone network monitor the background sound around the auto dialer 6 Setting guard delay time 0 90 seconds for four guard zone 7 Setting alarm delay time 0 90 seconds for four guard zone alarm signal 8 Siren hooting time length control option 1 20 minutes 9 Telephone line cut off alarm function option 10 Six wireless distinguishable guard zones LED indicator on the main set 11 Each of the four guard zones can be set on guard or withdraw guard independently 12 One panic key for help provided on the main set 13 Two panic keys for help is provided on the remote controller which will make the main dialer give out loud sound or not as well as dialing when being trigged 14 Convenient key input is prepared on the front panel Various kinds of door magnetic switch and PIR infrared detector are configurable Rechargeable DC9V power transformer provided for power cut backup O
8. PERATION METHOD Fig l System connection illustration note the extension can connected to your telephone machine telephone line to wall landline power supply extension line to other phone device Set guard and withdraw guard This alarm system can be divided into 6 alarm guard zones Each guard zone can configured with several door entry detectors infrared detectors gas leakage detectors and smoke detectors You can set guard or withdraw guard using the remote controller or by pressing the keypad on the main set 1 Setting guard by using remote controller Setting guard Press and release key on the remote controller GUARD LED on the main set will light up buzzer beep time the main set went into status of setting guard At this time if the main set received the alarm signals from detectors it will alarm if set no delay time but if you set a delay time for guard for example 30 seconds setting guard will take into effect only after 30 seconds later from the time you pressed the a key This delay time can be normally left for you to prepare to exit your house entry 1 2 4 5 6 e zone 3 LED GUARD POWER N e Indicator Fig 2 Setting panel illustration P2 Withdraw Set guard Emergency with sound Fig 3 Remote controller illustration withdraw guard setting by remote controller Press and release m key on the remote con
9. address code zone 4 code Fig 18 the 8 bit address code in the middle row is set as 11011220 the zone code is 2111 zone 4 Zone 5 code is 1221 Zone 6 code is 1212 If you want to add detector to your alarm set there will be two method the first method is you configure the detectors according to the short jumper slip setting way same as the detector in your standard kit the second method is you consult the 8 bit address code from the Product No on the bottom of your alarm set and encode 4 bit zone code following the above schematic diagram as you need P 13 Q PT2262 S DOD1D2D3 zone code A0A1A2A3AQ4A5A6A7 8 bit address code Fig 19 illustration diagram of R F emitting module The wireless smoke detector and gas leakage detector each has an wireless emitting module inside the plastic cover There are also 36 pins to set the 8 bit address code and 4 bit zone code on the emitting module The 8 bit address code is on the bottom side and the 4 bit zone code is on the right side the 8 bit address code is also same as infrared detectors for the same alarm set but we can set the 4 bit zone code as 24 hours guard zone of course you can also set the zone code as zone 1 2 3 4 as you like The 24 hours guard zone will report alarm messages even if you withdraw guard OQ 2 2 1 2 24hourS zone code emergency code 8 bit address code Fig 20 illustration diagram of R F emitting module encoding A wireless emergency but
10. group number 1 6 telephone number store For example if you want to store first group telephone numbers such as 66778899 you press key four digit password such as 1234 or other at first then press store then press 1 which means first group then press then press 66778899 then press store this finish first group numbers storing PA For example if you want to store second group telephone numbers such as 012345678 you press key four digit password such as 1234 or other at first then you press key store then press 2 which means second group then press then press 012345678 then press store this finish second group numbers storing You can store maximum total six groups of telephone numbers respectively If your alarm telephone connected to an extension telephone line and have to dial a digital number such as 9 or 0 etc Before input the telephone number you can store the alarm telephone numbers like this Press key four digit password such as 1234 or other at first then you press key store group number 1 6 9 0 ect telephone number store 2 Delete alarm telephone number Press key four digit password such as 1234 or other at first then you press key store group number 1 6 store For example if you want to delete second gro
11. irst then you press key program 8 this function will not make the alarm system hooting when its telephone line cut off 12 Modify user password Press key four digit user password such as 1234 or other at first then you press key program key 9 key program key four digit new password key program the initial user password settings is 1234 this user password A must remember If you forget this password you can press down the gg for ten seconds you will hear a short beep and a long beep sound the password will restore to its initial settings 1234 Receiving alarm messages and processing When alarm broke out the siren will sound as you selected the system will automatically dial out the pre stored telephone numbers and send memo messages to the alarm caller telephone When you connected on your telephone to the alarm set and hear the pre recorded memo messages by the telephone you can press the key on your telephone to process the alarm messages as you need You can input the digital key on your caller telephone as follows Press key 1 set guard Press key 2 withdraw guard Press key 5 start up siren Press key 6 shut off siren Press key 7 open background monitor Press key 8 close background monitor Press key 9 withdraw guard and auto dialer hook on If you press key 7 on your caller telephone you can monitor the sound given out
12. s will be stored to its initial settings as it manufactured out This function is often useful to diagnosis the obstacles which may be resulted by your wrong setting 7 Alarm siren hooting time setting Press key four user digit password at first then you press key program 3 program time 1 20minutes program Siren hooting time when alarm taking place can be set to 1 20minutes its initial value is 1 minute 5 8 Setting guard with delay option Press key four user digit password at first then you press key program 5 program time 1 90seconds program Setting guard with remote controllers or by pressing keypad will be valid after delay this option time its initial value is zero no delay 9 Setting alarm delay time Press key four user digit password at first then you press key program 6 program time 1 90seconds program When the main set received alarm signal under guard state it will wait a period of time 0 90seconds and then report alarm the initial value is zero no delay 10 Open telephone line cut off detect function Press key four user digit password such as 1234 or other at first then you press key program 7 this function will make the alarm system hooting when its telephone line cut off 11 Close telephone line cut off detect function Press key four user digit password such as 1234 or other at f
13. stem has only one address code but can have several zone code The address code is for communication only we printed it out on the bottom side of the alarm set marked as Product No the zone code is used to distinguish different alarm signal from different detectors or same kind detectors with different encoding For example we have 4 LED indicator on the keypad of the alarm set the alarm 1 LED is corresponding to zone 1 the alarm 2 LED is corresponding to zone 2 the alarm 3 LED is corresponding to zone 3 the alarm 4 LED is corresponding to zone 4 etc We use the short jumper slip option to realize the encoding you can use a screw driver to take off the screw of the infrared detectors and open the cover on the power switch side of the electronic circuit board you can see 36 metal pins this 36 metal pins is used to encode the 8 bit address code and 4 bit zone code 8 bit address code 4 bit zone code Fig 3 built in circuit of infrared detector You can also open the emitter part of the door entry contacts there are also 36 metal pins on the side of the electronic circuit board this 36 metal pin is also used to encode the 8 bit address code and 4 bit zone code P9 C2262 NM EN E S 5 5 5 8 bit address code 4 bit zone code Fig 5 built in circuit of door entry detector There are total 3 row pins each row has 12 pins the 12 pins in the row near the IC SC2262 or HS2262
14. t even in guard state but other detectors belong to other zones will be working as usual P3 withdraw guard setting When not in alarm state press four digits user password consecutively for example 1234 etc then press key set then press digit 0 the GUARD LED on the main set will go out the main set went into status of withdraw guard At this time if the main set received the alarm signals from detectors of zone 1 2 3 4 5 6 it will not alarm When in alarm state simply press four digits user password on the keypad will cancel guard and stop alarm Each guard area is corresponding to a LED indicator on the front panel when alarm takes place the corresponding LED light up then the alarm system dial out the telephone numbers and alarm The guard zone doesn t mean the same area that is to say detectors in different places can be configured into the same guard zone and light up the same alarm LED As how to configure a detector to a guard area will be illustrated later When this alarm unite manufctued out its initial status is setting full guard In this standard configuration kit standard configuration the enclosed door entry detector door contacts is configured to the guard zone 2 the enclosed infrared detector is configured to guard zone 1 according to your need you can add any detectors to guard 1 2 3 4 5 6 which corresponding to the LED indicator respectively Partial guard setting only zone
15. ton is generally configured as 24 hours guard zone in the same method P 14 v PT2262 S Ee 2 j 79 m s s c HON g 22211101 Pam 8 bit address code Fig 21 illustration diagram of RF emitting module encoding PRODUCT QUALITY GUARANTEE CARD WIRELESS INTELLIGENT DECURITY AND PROTECTION ALARM SYSTEM PRODUCT QUALITY GUARANTEE CARD Model product number invoice number purchase date Date Maintenance record P 15
16. troller the GUARD LED on the main set will go out the main set went into status of withdraw guard At this time if the main set received the alarm signals from all detectors of zone 1 2 3 4 5 6 it will not alarm 2 setting guard by pressing keypad on the main set Setting guard on the keypad When not in alarm state press four digits user password consecutively for example 1234 ect then press key set press digit 9 the GUARD LED on the main set will light up main set went into status of setting guard At this time if the main set received the alarm signals from detectors it will alarm at once or delayed for a period of option time 0 905 withdraw guard on the keypad Press four digits user password consecutively then press key set then press digit 0 the main set went into withdraw guard in this state if the main set received the alarm intruder signal from the detectors it will not alarm but if it received trigger signal from the panic button of the remote controller it will alarm and dial out telephone numbers automatically 3 Open or close a guard zone alarm Each of the four guard zone can be opened or closed if a guard zone is closed the main set will not report out alarm signal from the guard zone received For example if a PIR detector or door contacts is set belong to guard zone 3 when this detector emit signal to the alarm main set the main set zone 3 will not report signal ou
17. up telephone numbers press key four digit password such as 1234 or other at first then you press key store then press 2 which means second group then press then press store this delete second group telephone numbers 3 Alarm memo recording Press key four digit password such as 1234 or other at first then you press key record and release the record LED indicator light up you can start record speaking time not more than 10 seconds then press the key record again the record LED indicator went out this finished the recording process Record content can be as this is alarm telephone which place which home has found illegal intruders please help to process it 4 Setting alarm with sound Press key four digit password such as 1234 or other at first then you press key program key 1 the system will give out sound when alarm taking place The initial setting is alarm with sound 5 Setting alarm with no sound Press key four digit password such as 1234 or other at first then you press key program key 2 the system will not give out sound when alarm taking place 6 Clear all setting and restore to its initial values Press key four digit password such as 1234 or other at first then you press key program then press key 4 This function clear all settings but the user password include pre stored telephone numbers all setting