Home
Display - Futurasmus KNX Group
Contents
1. Figure 5 Reset button and USB port Extended programming via the front USB port Pictures and symbols to order see the user manual for this are transferred via the front mini USB socket E see figure 5 The USB socket is accessible after dismounting the design frame see above Connect the display to any Technical Manual Update http www siemens com gamma 2 3 1 7 5 GAMMA instabus Technical Specification March 2010 Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box PC with a USB interface type A via a USB cable with a type B mini USB plug The USB cable is part of the shipment and is enclosed in the touch panel It has a length of 1 m and have a transfer rate of 480 MBit sec After completing the transfer remove the cable and mount the design frame as described above Care instructions The display s design frame and plastic surface can be cleaned with off the shelf solvent free cleaning agents The display surface itself should be cleaned with a soft damp cloth e g spectacles cloth and if necessary a mild glass cleaner Do not use any mechanical aids rough sponge or similar materials for cleaning The touch screen surface is easy to scratch Dimension Diagram The following sketch shows the exact dimensions of the device Dimensions ar
2. SIEMENS Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box Product and Function Description Konferenz 1 B ro 1 Konferenz 2 Biiro 2 Besprechung 1 Rezeption Besprechung 2 K che Lobby Flur Nia eer Se The Colour touch panel UP 588 is a multi functional display control device for the KNX The basis of the device is a 320 x 240 pixels TFT colour display with touch screen The colour depth is 263 K R G B 6 bit 218 colours You operate the panel directly via the touch screen The display has LED background illumination which you dim with the user interface e UP 588 13 Colour touch panel 230V AC e UP 588 23 Colour touch panel 24V ACIDC In conjunction with the corresponding application program the display can be used to display and control up to 110 KNX functions of at least 20 control and display pages Time programmes with weekly schedules a presence simulation feature and scenes can be programmed for these functions or logic functions set up With a trend modul status values can be represented graphically over the time Up to 16 active alarms can be indicated and acknowledged on a alarm page or there is an option to use these activating conditions for 16 event tasks The panel has an internal real time clock and can therefore function as the master timer in a KNX
3. system Via the system settings one of four different design templates can be selected for the display and operator interface 5WG1 588 2AB13 5WG1 588 2AB23 Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg UP 588 6 pages Siemens AG 2010 Subject to change without further notice GAMMA instabus Technical Specification March 2010 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 The following accessories are needed for the colour touch panel Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white Relevant flush type box 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 Application programs 25 CO Touch Panel 910201 e Display and control of 110 KNX functions via at least 20 display and control pages Each viewing and control page includes up to 5 standard functions and 6 supplementary functions A standard function can contain up to 3 communication objects An supplementary function contains 1 communication object e Implementation of time programmes with weekly schedules for standard and supplementary function objects e Implementation of a presence simulation with standard and supplementary function objects e Implementation of scene programs with standard and supplementary function objects e
4. with the named accessories in particular the flush type box e 230V devices which are not included with supply may not be inserted in the flush type box It is also not possible to loop through 230V cables e The prevailing safety and accident regulations should be observed e The power supply voltage may only be connected to the supply if the device has been fully installed e Protective isolation should be ensured between the bus cable and the 230V power supply e For planning and construction of electric installations the relevant guidelines regulations and standards of the respective country are to be considered 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 Technical specifications Power supplies e Bus voltage via the bus line e External power supply for e Colour Touch panel UP 588 13 230 V AC 10 50 60 Hz e Colour Touch panel UP 588 23 18 36 V DC 400 mA base isolated comp 230 V 14 28 V AC 400 mA base isolated comp 230 V Operating elements e Programming button to toggle between normal and addressing modes e Reset button to reset the device e Resistive analogue touch with contact sensitive area on the display Display elements e Red programming LED for displaying normal addressing mode e Graphics capable TFT colour display 320 x 240 pixels 1 4 VGA with LED background lighting e Display fault like ISO 13406 2 fault league 3 by er
5. EC 1140 e Overvoltage category III e Bus safety extra low voltage SELV 24V DC e Device complies with EN50090 2 2 EMC requirements Complies with EN 61000 6 3 EN 61000 6 2 and EN 50090 2 2 Ambient conditions e Climatic withstand capability EN 50090 2 2 e Ambient operating conditions 0 C to 45 C e Storage temperature 25 C to 70 C e Relative humidity non condensing 5 to 93 Markings KNX EIB EC mark In accordance with the EMC guideline residential and functional buildings and the low voltage guideline Location and function of the conjunction and operating elements The device connections as well as the programming button and programming LED which are required for the commissioning stage are accessible at the back of the ye Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg GAMMA instabus Technical Specification March 2010 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 device Figure 2 shows the back of the device P Prog mm i okl om A DO OD onw UP 588 6 pages Siemens AG 2010 Subject to change without further notice Figure 2 Location of the connection and operating elements Connection te
6. Logic functions can be produced with supplementary function objects e Graphic display and storage of different status values over miscellaneous time periods e Display of an alarm page with 16 alarm messages e Alternatively the alarm activation conditions can be used for 16 event tasks e Date and time display integrated real time clock e Individual password protection for each page for scene weekly schedules logic programs and presence simulation e Selection out of four different design templates for the display and operator interface e Display of individual images on the start screen page or up to 100 alternating images as a slide show Installation notes e The device can be used for permanent interior installations in dry rooms e A masonry wall or cavity wall recess 161 5 x 135 x 64 mm is required to install the mounting socket Technical Manual Update http www siemens com gamma 2 3 1 7 1 GAMMA instabus Technical Specification March 2010 Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box e The depth of the recess must be at least 64 mm Figure 1 Drilling jig for cavity wall box Colour touchpanel UP 588 A DANGER e The device may only be installed and commissioned by an authorised electrician e The device may only be used in connection
7. e given in mm Technical Manual Update http www siemens com gamma 2 3 1 7 6 UP 588 6 pages Siemens AG 2010 Subject to change without further notice 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 General notes e Any faulty device should be returned to the local Siemens office e If you have further questions concerning the product please contact our Technical Support 49 911 895 7222 49 911 895 7223 lt support automation siemens com http support automation siemens com Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg
8. lot of the grey part of the bus terminal C3 3 and Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg UP 588 6 pages Siemens AG 2010 Subject to change without further notice GAMMA instabus Technical Specification March 2010 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 then pull the bus terminal C3 out of the device When pulling out the red part of the bus terminal the grey part remains plugged in Notice Do not lever the bus terminal outwards from below Danger of short circuit Disconnecting the bus terminal figure 4 A Pull off the bus terminal C3 and pull out its conductor C3 4 by turning it alternately backwards and forwards Resetting the device if there is an error You reset the touch panel in the event of an error with the reset button The reset button F see figure 5 is accessible after dismounting the design frame see above This is done with the special tool Should the display fail in rare cases owing to a fault in the software or during the loading process tap the reset button The device then restarts within a few seconds and the design frame can be remounted as described above If the device will not start despite a reset contact the manufacturer
9. mounting is completed the device can be used for programming see the application program description Please note the device can only be started after the power supply and the bus voltage have been switched on and this may take up to 1 minute Dismantling exchanging the design frame First of all switch off the power supply The passepartout blind must be removed initially to dismount the device or exchange the frame A Caution Do not press directly on the display After removing the passepartout blind the design frame can be exchanged or the device dismounted completely Disconnecting the power supply figure 4 B To dismount the power supply terminal C4 this must be pulled downwards over the detente and out of the slot The removal can be made easier by lifting the power supply connection terminal C4 slightly with a flat bladed screwdriver To do this push the blade of the screwdriver into the centre of the terminal detente between the power supply connection terminal C4 and the base of the slot Removing the bus terminal figure 4 A The bus terminal C3 is in the left slot It consists of two parts C3 2 and C3 3 each with four terminal contacts You must take care that both test sockets C3 1 are not damaged either with the bus conductor accidental attempt to plug in or with the screwdriver e g when trying to remove the bus terminal Push the screwdriver carefully into the wire connection s
10. ower supply to the conductors the terminals are plugged into the corresponding outlets on the touch panel The power supply must only be switched on when the plug is engaged firmly in the device After switching on the bus voltage and the power supply the programming button can be pressed and the physical device address programmed The LED must go out after programming the physical address The device is then screwed into the flush type box with the four screws 3 enclosed see figure 3 The protective film applied to the display surface can now be removed Do not use any sharp items or tools to do this After the screwing the display modul and the removal of the protective film the design frame 4 can be plugged Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box into the device At the same time take note of the direction for mounting the frame Finally the passepartout blind 5 are plugged on to the display and thus held by the frame The mounting direction must also be observed when mounting the passepartout blind It is to be plugged in such that all elements of the display frame are covered completely A Caution Do not press directly on the display After
11. rminal 230 V or 24 V ACIDC Programming LED Programming button Bus terminal Al Figure 3 Mounting the touch panel f J 1 Flush type box ji 2 Colour touch panel we 3 Fixing screws On 4 different design frames 5 Passepartout blind 5 Technical Manual Update http www siemens com gamma 2 3 1 7 3 GAMMA instabus Technical Specification March 2010 Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box The bus cable is connected via a standard bus terminal D which is plugged into the corresponding terminal slot on the right side of the housing On the left beside the plug in slot for the bus terminal are the programming button C and the programming LED B The connection terminal for the 230 V power supply or in the 24 V version for 24 V supply are on the left side A of the device The terminal must be removed to connect the power supply It is essential to obey the connection sequence marked on the housing Mounting and wiring General description The device 2 may only be mounted in the flush type box 1 to be ordered as an accessory When the cable is brought into the flush type box take care that the bus cable is fed in through the bottom left hand recess and the power supply cable is fed in through the right hand recess The bus and power supply cables mu
12. ror type 1 and error type 2 Connections e Bus line KNX bus terminal screwless 0 6 0 8 mm solid stripped length 5 mm e USB socket mini typ B use only if needed for image and symbols load e Power supply stripped length 6 7 mm The following conductor conductor cross sections are permitted 0 5 2 5 mm solid 0 5 0 1 5 mm finely stranded Mechanical data e Housing Touch panel plastic e Outer dimensions of the display modul W x H x D 157 x 131 x 60 mm e Outer dimensions of the design frames W x H x D 194 x 156 x 5 mm e Outer dimensions of the passepartout blind W x H 152 x 123 mm e Mounting depth in flash type box 64 mm e Installation is screwed into the corresponding flush type box Technical Manual UP 588 6 pages Update http www siemens com gamma 2 3 1 7 2 Siemens AG 2010 Subject to change without further notice Siemens AG Industry Sector Building Technologies Low Voltage Distribution PO Box 10 09 53 D 93009 Regensburg Colour touch panel UP 588 13 Colour touch panel UP 588 23 Accessories Design frame aluminium Design frame stainless steel design Design frame glass black Design frame glass white flush type box e Dimensions of corresponding flush type box W x H x D 161 5 x 135 x 64 mm not included with supply e Weight approx 510g Electrical safety e Degree of pollution 2 e Type of protection according to EN 60529 IP20 e Protection class to I
13. st not be fed into the flush type box through the same recess Inside the box the cable is to be routed so that there is a guaranteed separation of at least 10 mm between bus and power supply cables Connecting the bus cable figure 4 A The bus terminal C3 is suitable for solid conductors with a diameter of 0 6 0 8 mm Strip off approx 3 cm of the bus cable insulation Strip the insulation from the conductors C3 4 to a distance of approx 5 mm and plug it into the terminal C3 red grey Clipping on bus terminal figure 4 Plug the bus terminal into the guide slot and press it C3 downwards to the end stop Technical Manual Update http www siemens com gamma 2 3 1 7 4 UP 588 6 pages Siemens AG 2010 Subject to change without further notice 5WG1 588 2AB13 5WG1 588 2AB23 5WG1 588 8AB12 5WG1 588 8AB13 5WG1 588 8AB14 5WG1 588 8AB15 5WG1 588 8EB01 C3 ag C3 3 C3 2 C3 4 A B Figure 4 Connections Connecting the power supply Figure 4 B Strip the insulation from the conductor C4 1 toa distance of 6 7 mm plug it into the power supply connection terminals C4 and tighten the screws C4 2 Terminal assignment 230V 24V 1 Earth In1 DC AC L 2 N Neutral conductor not connected 3 L Phase In2 DC AC After connecting the bus terminal and the p
Download Pdf Manuals