Home
PINPAD Single Door Access Controller
Contents
1. Max 160mA Input Port 1 Port Exit Button 2 Ports Form C Relay Output COM NO NC Output Port DC12 18V Rating Max 2A 1 Port 1 Port Chime Bell Output DC5V Rating Max 500mA Bell Output DCSV Rating Max 1 Port Chime Bell Output DC5V Rating Max 500mA 12 Key Numeric Keypad with Back Lighting Operating Temperature 35 to 65 C 31 to 149 F Dimension W x H x T 87mm x 100mm x 31mm a 4 x 3 94 x 1 22 Weight 1629 0 3665 6 Installation 6 1 Drill two 6 32 or M3 holes 3 3 8 38cm apart in vertical and one 1 2 hole at the centre of these two holes If you have installed electric gang box then skip this step 6 2 Using two 6 32 or M3 screws install wall mount to the wall 6 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the centre hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount Star PIN120 6 32 hole 1 85 47mm EI pt a aei wi af 1 79 45 5mm 2 05 52mm 1 52 38 5mm 1 52 38 5mm 3 03 7 fmm 7 Wire Color of Table SIGNAL COLOR Main Power 12V Red Power Ground GND Black Door Relay Out COM Green Door Relay Out NC Blue Door Relay Out NO Purple Alarm Relay Out COM Yellow Alarm Relay Out NC Orange Alarm Relay Out NO Gray Chime Bell Out Brown Exit Button In White Please cut out tail connector be
2. IMS ANY AND ALL WARRANTY WHETHER EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR OTHER LOSS AND IDTECK S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT To obtain repair or replacement under the terms of this warranty visit IDTECK s Website http www idteck com and place an online RMA request After an RMA code is issued return the product along with the authorization RMA code 10 IDTECK Star PIN120 RMA REQUEST FORM IDTECK accepts only on line RMA requests on our Website www idteck com Please provide us with basic information in the below form so that we can understand your problems better Send us back this form with your products after an RMA code is issued on our Website This form is not compulsory RMA Authorization Code 1 Company Name 2 Model Name 3 Serial No 4 Original Invoice No 5 Distributor 6 Purchasing Date 7 RMA Request Date Pleas
3. User s Manual Star PIN120 PINPAD Single Door Access Controller Star PIN120 Table of Contents Li Important Safety INSWUCTONS ssssssssosnsnsnnnnonononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 3 2 GONE Mal ciaisiiasnaisiveniaisineniivnivivtiensisasnnvenuivisinivininiiietanniaruunNiivineNiiiinsisiNiaiUiias 3 3 IAENUTYING Supphed Parts sisissieissasrssistsssstssrccersacsinaisaiiasieniadsaseieanainninsT 4 A FeAtUTES rusis atin Nii eniuRIiNINNAIN 4 5 S PECINCAUON inina 5 INSTAIAUON gsc 5 Te WIRE COON of Tall QisssasstassanscstsssericeiincstivinrsinnsienniaiaineniiisinainnmieiinaiaT 6 3 Wire C ONGC TOM enmisimiana a 7 9 OPSralOn ponnn 7 10 FCC Registration Information sscssssssssscsscsecssesecsesesessesseseesecseseesecseseseees 10 11 Warranty Policy and Limitation of Liability ssssssssssssssssssssessecsssesecseseseess 10 IDTECK Star PIN120 1 Important Safety Instructions When using your Single Door Controller basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following should also be followed gt Read and understand all instructions NO Follow all warnings and instructions marked on the product Go Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap D Do not use this product near water such as bath tub wash bowl kitchen sink laundr
4. e check your problems o Card Reading o Power o Keypad o Communication o Relay o LCD o LED amp Buzzer o Registration o Others IDTECK RMA Center gt gt 3F 10 10 1 10 2 Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 157 030 Korea Telephone 82 2 2659 0055 HQ 82 32 671 5642 RMA Center Fax 82 2 2659 0086 HQ 82 32 671 5641 RMA Center Website www idteck com e Training Center www idtecktraining com MAMPINIHE2X Nov 2008 Copyright IDTECK Co Ltd Star PIN120 eve The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com MAMPINIHE2X Nov 2008 Copyright IDTECK Co Ltd
5. fore installation Star PIN120 IDTECK 8 Wire Connection Exit Button Input Exit Chime Bell Output g Button Power Ground GND Main Power 12 V Door Relay Alarm Relay COM COM Door a Relay NO 7 12V I GND ja Chime Door Bell Lock Siren 9 Operation 9 1 Initial Settings PIN120 is completely blank when it is delivered to customer The unit automatically enters to initial setting mode program mode when it is powered up You may also erase all memory by turn on the power after connecting 2wires White and Brown Programming sequence is as follows Connect 12V DC Power supply to RED and BLACK wire then power up m You can hear the tune Sol Fa Mi Re Do and all three LEDs on m Press the keypads as follow 6 digit Master ID ENT Tune uoa red amp green LED on 4 6 digit Access ID ENT red LED on Up to 512 Access ID ENT C 6 digit Master ID a Tune Do Sol Mi Do IDTECX Star PIN120 Example You want to set Master ID 123456 and Access ID 1111 22222 and 345678 123450 ENT Register Master ID 1111 ENT Register Access ID 22222 ENT Register Access ID 345678 ENT Register Access ID 123450 ENT Finish Setting Note Master ID must be 6 digits long and Access ID is 4 6 digit and ESC key is to cancel the ke
6. ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help 11 Warranty Policy and Limitation of Liability IDTECK warrants this product against defects in material and workmanship for 3 years from the date of purchase under normal customer use This Warranty doesn t apply 1 to any product which has been dismantled without authorization of IDTECK or and has a damaged or detached QC label on its back side 2 to any losses defects or damages caused by improper testing operation installation maintenance modification alteration or adjustment 3 to any product with a damaged or faded serial number on it or 4 to any losses defects or damages caused by lightning or other electrical discharge natural disaster misuse accident or neglect This Limited Warranty is in lieu of all other warranties obligations or liabilities on the part of IDTECK and IDTECK DISCLA
7. th bell sound 9 4 Setting Changes Reset All Outputs all Relays and Bell output OFF Master ID ENT Add New Access ID Master ID ENT 11 ENT New Access ID ENT Delete Access ID Master ID ENT 13 ENT Delete Access ID ENT Door Relay Time Set Time 00 99 seconds Master ID ENT 21 ENT TIME ENT Alarm Relay Time Set Time 00 99 seconds Master ID ENT 22 ENT TIME ENT Bell Output Time Set Time 00 99 seconds Master ID ENT 23 ENT TIME ENT Keypad Input Limit Time Set Master ID ENT 25 ENT TIME ENT Time 10 99 seconds Tamper Alarm ON Master ID ENT 41 ENT Quick Access Mode OFF Master ID ENT 62 ENT IDTECK Star PIN120 10 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any set a or modifications in construction of this device which are not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This sel must accept any interference received including interference that may cause undesired operation This egipmen has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructi
8. uct exhibits a distinct change in performance 2 General The Star PIN120 is an intelligent single door keypad controller that combines the convenience of entry control with the security of an alarm system Also the Star PIN120 will also give you field proven reliability and cost effective solution anywhere access controls and security are required The Star PIN120 can interface and operate with EXIT button Also output ports which include 2 Relays and 1 Bell Moreover the status or behaviours of these input and output accessories are configurable to provide the system administrator with complete customized control of the system IDTECK 3 Identifying Supplied Parts Please unpack and check the contents of the box Star Pini PIN120 Wall Mount lea 1ea raara WAN 3 5 40 Screw 3 5 12 Screw 4ea 4ea 4 Features PINPAD Single Door Access Controller 512 Users User Defined 4 6 digit PIN Star PIN120 Star PIN120 Pin p Prpraity EMPL Bingo Pidi direvi Caia 4 l O ring User s Manual 5ea 1copy Anchor Bolt 4ea Independent 1 Input and 3 Outputs including 2ea of 2 Form C Relay Outputs Operation Time of All I Os Programmable by Keypad Keypad Lock by Try out Error Alarm Function Chime Bell Output Tamper Switch IDTECK Star PIN120 5 Specification 8bit Microprocessor Program 3 8KBtyte ROM Memory Memory Data Memory 2KByte EEPROM Power Current DC 12V
9. y input for example if you want to press 123456 but you pressed 112345 then press ESC key to cancel 112345 then press 123456 ENT to correction m The unit now enters to normal operation mode m With above sequence you already registered MASTER ID and USER ACCESS ID and the other default settings are automatically set and stored into flash memory 9 2 Default Setting Values When Access ID Granted Door Relay and green LED activate for 3 seconds Exit Input Entered Door Relay and green LED activates for 3 seconds Alarm Relay and red LED activates for 2 seconds When Access ID denied within Try out count Alarm Relay and red LED activates for 2 seconds and When Try out error occur Keypad locks for 60 seconds from 3rd Try out Bell sound Mi Do Mi Do Bell ESC key pressed Bell output open collector activates for 5 seconds Numbers of Try out count Keypad input limit time 20 seconds IDTECK Star PIN120 9 3 Normal Operation Yellow LED is blinking every second Operating Outputs 4 6 digits Access ID ENT If Access ID is granted Door Relay and green LED activates lf Access ID is denied Alarm Relay and red LED activates Exit Input Entered Door Relay and green LED activates Quick Access only activates when Quick Access Mode ON ENT m Door Relay and green LED activates BELL only activates when BELL Output Time set ESC Bell output open collector activates wi
10. y tub in a wet basement or swimming pool 5 This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company O gt Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used CO Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c If the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d If the prod
Download Pdf Manuals
Related Search
Related Contents
Lee Valley Tools - Enfile user`s manual - JS manuale d`uso instruction manual manuel d`utilisation 操作ガイドSMT-3C Hotpoint Washer/Dryer BHWD 129 User's Manual Philips myLiving Ceiling light 30184/43/16 LG-D105f - Multisom eMEVS User Manual - Louisiana Medicaid EC Line EC-LS-9610 bar code reader Copyright © All rights reserved.
Failed to retrieve file