Home
Basic-type Digital Temperature Controller E5AN
Contents
1. E5AN Controllers with Terminal Blocks Power an Functions Cc Auxilia Size er supply Input type park Control output 1 Heater Power supply Control Model voltage burnout for Sensor output 2 Relay output E5AN R3MT 500 N Voltage output k CEAN for driving SSP E5AN Q3MT 500 N Current output E5AN C3MT 500 N Relay output 1 E5AN R3HMT 500 N Voltage output i END for driving SSP 1 E5AN Q3HMT 500 N Relay output 2 E5AN R3HHMT 500 N Voltage output 2 enn for driving SSR 2 E5AN Q3HHMT 500 N Thermocouple or 5 Relay output Voltage E5AN R3QMT 500 N output Resistance thermometer Voltage output Voltage i RAA for driving SSR output PAN ASOMT SRON Current output ae ES5AN C3QMT 500 N se we Relay output E5AN R3YMT 500 N Voltage output Long life ge Supu relay E5AN Q3YMT 500 N for driving SSR output Current output E5AN C3YMT 500 N Relay output Sensor Power E5AN R3PMT 500 N Black Voltage output for driving SSR Sensor Power E5AN Q3PMT 500 N Relay output E5AN R3ML 500 N Voltage output a ENO for driving SSR Eset eer bi Current output E5AN C3ML 500 N x x WxHxD Analog 3 Relay output 1 E5AN R3HML 500 N current voltage Voltage autput E5AN Q3HML 500 N for driving SSR Long life Voltag culpur relay ES5AN Q3YML 500 N for driving SSR output Relay output E5AN R3MTD 500 N Voltage output IRAN for driving SSP E5AN Q3MTD 500 N Thermocouple Current output E5AN C3MTD
2. Dielectric strength 2 300 VAC 50 or 60 Hz for 1 min between terminals with different charge Vibration Malfunction 10 to 55 Hz 20 m s for 10 min each in X Y and Z directions resistance Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 hrs each in X Y and Z directions Shock Malfunction 100 m s 3 times each in X Y and Z directions resistance Destruction 300 m s2 3 times each in X Y and Z directions 7 E5AN Controller Approx 310 g Mounting Bracket Approx 100 g weignt E5EN Controller Approx 260 g Mounting Bracket Approx 100 g Degree of protection Front panel IP66 Rear case IP20 Terminals IP00 Memory protection Non volatile memory number of writes 1 000 000 times Setup Tool CX Thermo version 4 0 or higher Setup Tool port Provided on the bottom of the E5AN and E5EN An E58 CIFQ1 USB Serial Conversion Cable is required to connect the computer to the E5AN and E5EN 6 Approved SELEENI UL 61010 1 CSA C22 2 No 1010 1 Standards Conformed EN 61010 1 IEC 61010 1 Pollution level 2 overcurrent category Il Lloyd s standards 7 standards i i i EMI EN 61326 Radiated Interference Electromagnetic Field Strength EN 55011 Group 1 class A Noise Terminal Voltage EN 55011 Group 1 class A EMS EN 61326 ESD Immunity EN 61000 4 2 EMC Electromagnetic Field Immunity EN 61000 4 3 Burst Noise Immunity EN 61000 4 4 Conducted Disturbance Immunity
3. The voltage output control output 2 for driving SSR has basic insulation provided for the internal circuit e Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose Controllers Option Units The E5UIN TO is set for a K type thermocouple ee INDET A input type 5 by default An input error 5 ERR will l Communications i no polarity occur if the input type setting does not agree with the l E53 EN01 E53 EN03 E53 AKB l l Control output 1 temperature sensor Check the input type RS 232C RS 485 Event inputs Relay output SD B aa l 250 VAC 5A Event Inputs 1 RD A OA l resistive load l EJE l Voltage output Input power supply 1 3 SG 13 DO NOTUSE Dkt i for driving SSR EV1 Ne See cee te S J 12 VDC 40 mA Current output Control output 1 CT1 CT2 Qontrol Output a Eternal Power Suppiy 0 to 20 mA DC Y to LPO MADO g Control output 2 oad max r External power supply Auxiliary output 3 DO NOT 12 VDC 20 mA 1 _ Control output 2 WSE DO NOT Voltage output i Kai Pie for driving SSR en ary QUipu A 12 VDO 21 a i T aed Long life relay output p E 2 mA 250 VAC 3A Auxiliary output 1 i A heater burnout alarm heater short alarm resistive load o H BJ i PO
4. EN 61000 4 6 Surge Immunity EN 61000 4 5 Power Frequency Magnetic Field Immunity EN 61000 4 8 Voltage Dip Interrupting Immunity EN 61000 4 11 1 The indication accuracy of K thermocouples in the 200 to 1300 C range T and N thermocouples at a temperature of 100 C max and U and L thermocouples at any temperatures is 2 C 1 digit max The indication accuracy of the B thermocouple at a temperature of 400 C max is not specified The indication accuracy of B thermocouples in the 400 to 800 C range is 3 C max The indication accuracy of the R and S thermocouples at a temperature of 200 C max is 3 C 1 digit max The indication accuracy of W thermocouples is 0 3 of PV or 3 C whichever is greater 1 digit max The indication accuracy of PL II thermocouples is 0 3 of PV or 2 C whichever is greater 1 digit max 2 Ambient temperature 10 C to 23 C to 55 Voltage range 15 to 10 of rated voltage 3 K thermocouple at 100 C max 10 C max 4 EU stands for Engineering Unit and is used as the unit after scaling For a temperature sensor the EU is C or F 5 When robust tuning RT is ON the differential time is 0 0 to 999 9 in units of 0 1 s 6 External communications RS 232C or RS 485 and cable communications for the Setup Tool can be used at the same time 7 Refer to information on maritime standards in Safety Precautions for E5LIN E5LIN H for compliance with Lloyd s Standards omRONn
5. 19 99 to 99 99 or 1 999 to 9 999 0 1 2 3 4 Shaded settings are the default settings Setting range Setting number omrRONn E5AN E5EN Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types The default is 2 Upper limit Auxiliary outputs are allocated for alarms ON delays and OFF delays 0 to 999 s can also be specified Note For models with heater burnout SSR failure and heater overcurrent detection alarm 1 will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout SSR failure and heater overcurrent To output only a heater burnout alarm SSR failure alarm and heater overcurrent alarm for alarm 1 set the alarm type to 0 i e no alarm function Alarm output operation Set value Alarm type When alarm value When alarm value Description of function X is positive X is negative 0 Alarm function OFF Output OFF No alarm 7 sient on t Hie Set the deviation in the set point by setting the alarm i Uppers and lower limit ORF SP aa upper limit H and alarm lower limit L ish ON x on e Set the upward deviation in the set point by setting 2 Upper limit ORF SP OFF SP the alarm value X i on ON in Set the downward deviation in the set point by setting 3 Lowerilimit OFF SF OFF SP the alarm value X E on LE He Set the deviation in t
6. Order Separately USB Serial Conversion Cable E58 CIFQ1 le 2 100 250 gt LED SD __ 1 765 a ee 22 USB connector type A plug LED RD Serial connector Terminal Covers E53 COV16 Six Covers provided si 104 44 8 omrRONn E5AN E5EN Waterproof Packing Y92S P4 for DIN 96 x 96 Y92S P5 for DIN 48 x 96 J Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 degree of protection Deterioration shrinking or hardening of the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 The time for periodic replacement depends on the operating environment Be sure to confirm this point at your site Consider one year a rough standard OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement The Waterproof Packing does not need to be attached if a waterproof structure is not required Current Transformers E54 CT1 E54 CT1 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 1842 Q 100 V 50 Hz oO Distortion a factor 10 3 1 Output voltage Eo V r m s 3 3 lt E54 C
7. REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attention
8. Voltage output Voltage 3 Enni thermometer for driving SSR output ESEN Q3QMT 500 N Voltage Current output output E5EN C3QMT 500 N 100 to Long life 240 VAC Relay output relay output E5EN R3YMT 500 N Voltage output Long life enn for driving SSR relay output ESEN Q3YMT S00 N Long life 7 ENO Current output relay output E5EN C3YMT 500 N Relay output Sensor Power E5EN R3PMT 500 N Voltage output d T for driving SSR Sensor Power E5EN Q3PMT 500 N Relay output E5EN R3ML 500 N 1 8 DIN Voltage output Pre 48 x 96 x78 for driving SSR E5EN Q3ML 500 N W x H x D Analog 5 Current output E5EN C3ML 500 N current voltage Relay output 1 E5EN R3HML 500 N 1 E5EN Q3HML 500 N Voltage output Conga for driving SSR Pil 500 iving SSR relay output ESEN Q3YML 500 N Relay output E5EN R3MTD 500 N Voltage output ean for driving SSR E5EN Q3MTD 500 N Thermocouple Current output E5EN C3MTD 500 N 24 VAC or Relay output 1 E5EN R3HMTD 500 N VDC Resistance 3 Voltage output thermometer for driving SSR 1 E5EN Q3HMTD 500 N Relay output 2 E5EN R3HHMTD 500 N Voltage output E END for driving SSR 2 E5EN Q3HHMTD 500 N Relay output E5EN R3MT W 500 N Voltage output 7 W E00 100 to for driving SSR E5EN Q3MT W 500 N 240 VAC Current output E5EN C3MT W 500 N Thermocouple Relay output 1 E5EN R3HMT W 500 N or a Resistance 3 Voltage output 4 E5EN Q3HMT W 500 N thermometer for driving SSR 24 VAC Relay output E5EN R3MTD W 500 N VDC Voltage ou
9. for heater current detection Models with detection for single phase heaters One input Models with detection for single phase or three phase heaters Two inputs Maximum heater current 50 A AC Input current indication accuracy 5 FS 1 digit max Heater burnout alarm setting range 1 0 1 to 49 9 A in units of 0 1 A Minimum detection ON time 100 ms SSR failure alarm setting range 2 0 1 to 49 9 A in units of 0 1 A Minimum detection OFF time 100 ms Heater overcurrent alarm setting range 3 0 1 to 49 9 A in units of 0 1 A Minimum detection ON time 100 ms RS 485 two wire half duplex or RS Communications 232C Synchronization method Start stop synchronization Protocol CompoWay F SYSWAY or Modbus 1200 2400 4800 9600 19200 38400 Baudirate or 57600 bps Transmission code ASCII Data bit length 7 or 8 bits Stop bit length 1 or 2 bits Vertical parity none even odd Frame check sequence FCS with SYSWAY Block check character BCC with CompoWay F or CRC 16 Modbus Error detection Flow control None Interface RS 485 RS 232C Retry function None Communications buffer 217 bytes Communications 0 to 99 ms response wait time Default 20 ms The baud rate data bit length stop bit length and vertical parity can be individually set using the Communications Setting Level 1 For heater burnout alarms the h
10. shipped from the factory A 3 level display is activated if parameters are initialized For details on the third display level refer to the User s Manual Basic Type Cat No H156 omrRONn E5AN E5EN Input Ranges Thermocouple Platinum Resistance Thermometer Universal inputs Platinum resistance Infrared temperature thermometer uhermocoupie sensor 60 to Pt100 JPt100 E L U 3 120 C Usable in the following ranges 900 by 800 scaling 700 1999 to 600 9999 or 199 9 500 to 999 9 400 300 200 100 0 100 0 E a o HA 200 0 6 o D Z g o g gt z o Q 5 ol 199 9 199 9 Setting number 10 i Shaded settings are the default settings The applicable standards for the input types are as follows K J T E N R S B JIS C 1602 1995 IEC 584 1 JPt100 JIS C 1604 1989 JIS C 1606 1989 L Fe CuNi DIN 43710 1985 Pt100 JIS C 1604 1997 IEC 751 U Cu CuNi DIN 43710 1985 PL II According to Platinel II electromotive force charts from BASF previously W W5Re W26Re ASTM E988 1990 Engelhard Models with Analog Inputs Input type Current Voltage Input specification 4 to 20mA 0to20mA 1to5V Oto5V 0to10V Usable in the following ranges by scaling 1999 to 9999 199 9 to 999 9
11. 40 to 260 C Voltage input 0 to 50 mV Models with analog inputs Current input 4 to 20 mA or 0 to 20 mA Voltage input 1 to 5 V 0 to 5 V or O to 10 V Input impedance Current input 150 Q max Voltage input 1 MQ min Use a 1 1 connection when connecting the ES2 HB Control method ON OFF control or 2 PID control with auto tuning Relay output a 250 VAC 5 A resistive load electrical life 100 000 operations minimum applicable load 5 V Voltage output Output voltage 12 VDC 15 PNP max load current 40 mA Control for driving SSR With short circuit protection circuit Max load current of 21 mA for control output 2 output Current output 4 to 20 mA DC 0 to 20 mA DC load 600 Q max resolution approx 10 000 Wonaslita rela SPST NO 250 VAC 3 A resistive load electrical life 1 000 000 operations load power supply voltage 75 amt 7 y to 250 VAC DC loads cannot be connected minimum applicable load 5 V 10 mA leakage current 5 mA P max 250 VAC 60 Hz Aeailiae Number of outputs 3 output Y Output Relay output SPST NO 250 VAC 3 A resistive load electrical life 100 000 operations minimum applicable specifications load 5 V 10 mA Number of inputs 2 Event Contact input ON 1 KQ max OFF 100 kQ min 7 External contact input F A p input specifications Non contact input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Curren
12. 500 N 24 VAC or Relay output 1 E5AN R3HMTD 500 N VDC Resistance 2 Voltage output thermometer for driving SSR 1 E5AN Q3HMTD 500 N Relay output 2 E5AN R3HHMTD 500 N Voltage output E EOD for driving SSP 2 E5AN Q3HHMTD 500 N Relay output E5AN R3MT W 500 N Voltage output i WEIN for driving SSR E5AN Q3MT W 500 N one Une Current output E5AN C3MT W 500 N Thermocouple Relay output 1 E5AN R3HMT W 500 N or Silver i 3 Voltage output Resistance ge ouput la E5AN Q3HMT W 500 N thermometer for driving SSR Relay output E5AN R3MTD W 500 N 24 VAC Voltage output i W_BN VDC for driving SSR PSAN OSMTOSNES0N Current output E5AN C3MTD W 500 N Note Models with analog inputs do not have temperature unit indicators omrRONn E5AN E5EN E5EN Controllers with Terminal Blocks Power a Functions Size o supply Input type Ere Control output 1 Heater Power supply Control Model voltage burnout for Sensor output 2 Relay output E5EN R3MT 500 N Voltage output 7 ENN for driving SSP E5EN Q3MT 500 N Current output E5EN C3MT 500 N Relay output 1 E5EN R3HMT 500 N Voltage output ean for driving SSR 1 E5EN Q3HMT 500 N Relay output 2 E5EN R3HHMT 500 N Voltage output E END for driving SSP 2 E5EN Q3HHMT 500 N Thermocouple Relay output a E5EN R3QMT 500 N or 3 Resistance
13. Basic type Digital Temperature Controller E5AN E5EN 96 x 96 mm and 48 x 96 mm CSM_ES5AN_ES5EN_DS_E 4 1 New 96 x 96 mm and 48 x 96 mm Basic Temperature Controllers with Enhanced Functions and Performance Improved Indication Accuracy and Du CE Preventive Maintenance Function e Indication Accuracy Thermocouple input 0 3 of PV previous models 0 5 Pt input 0 2 of PV previous models 0 5 Analog input 0 2 FS previous models 0 5 e A PV SV status display function can be set to automatically alternate between displaying the status of the Temperature Controller auto manual RUN STOP and alarms and the PV or SV e Preventive maintenance for relays in the Temperature Controller ae eee ESAN ESEN using a Control Output ON OFF Counter e Three level display that simultaneously displays the PV SV and MV N Refer to Safety Precautions for E5 IN E5LIN H e One touch operation with PF Key that can be assigned to auto Refer to Operation for E5SLIN E5LIN H for operating manual RUN STOP or other functions procedures Main I O Functions E5AN 3 level Display Simultaneously displays set items 5 such as the PV SV and MV k A 2 level display when shipped from the factory A 3 level display is activated if parameters are initialized For details on the third display level refer to the User s Manual Basic Type Cat No H156 Event Inputs e None Sensor Inputs e Unive
14. E5AN E5EN USB Serial Conversion Cable Applicable OS Windows 2000 XP or Vista Current Transformer Order Separately Ratings Applicable software CX Thermo version 4 or higher Dielectric strength 1 000 VAC for 1 min ES5AN E5EN E5CN E5CN U ESAN mpplleable models H E5EN H ESCN H ESGN USB interface standard Conforms to USB Specification 1 1 Vibration resistance 50 Hz 98 m s Weight E54 CT1 Approx 11 5 g E54 CT3 Approx 50 g DTE speed 38400 bps Computer USB type A plug Temperature Controller Setup Tool port on bottom of Controller Connector specifications Bus power Supplied from USB host Power supply controller Power supply voltage 5 VDC Current consumption 70 mA Ambient operating temperature 0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 20 to 60 C with no condensation Storage temperature or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 100 g Note A driver must be installed in the personal computer Refer to installation information in the operation manual for the Conversion Cable Communications Specifications RS 485 Multipoint RS 232C Point to point Transmission line connection method Accessories E54 CT3 only Armatures 2 Plugs 2 Heater Burnout Alarms SSR Failure Alarms and Heater Overcurrent Alarms CT input
15. NOT heater overcurrent alarm or input alarm is j ae input sent to the output to which the alarm 1 function is assigned universal input Auxiliary output Relay outputs AC 3A resistive load omRONn E5AN E5EN Nomenclature E5AN E5EN Temperature unit Operation indicators Temperature unit No 1 display M M M M i No 1 display A ALAA TE No 2 display No 3 display Operation indicators Mode Key pai ch Programmable Function Key Auto Manual Key Aen unction Key Auto Manual Key Mode Key A 2 level display when shipped from the factory A 3 level display is activated if parameters are initialized For details on the third display level refer to the User s Manual Basic Type Cat No H156 Dimensions Unit mm E5AN Mounted Separately Group Mounted 923 96 x number of units 3 5 4 e j 79 2 i goes 96 x 96 120 min f Group mounting does not allow waterproofing e Recommended panel thickness is 1 to t 8mm Group mounting is not possible in the vertical direction Maintain the specified 498 mounting space between Controllers 1 92 eTo mount the Controller so that it is 1 waterproof insert the w
16. T3 2 36 dia Two M3 depth 4 oat 2 E54 CT3 Accessory e Armature Connection Example Approx 3dia Plug z al So idee ia oS aes Armature e Plug to Approx 6 dia Eo es 1 10 100mA 1 10 100 1 000A Thru current lo A r m s E54 CT3 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Temperature Controller is 50 A Number of windings 400 2 Winding resistance 840 8 Q 100 V 2 50 Hz Distor tion gt 10 factor A 10 u 3 o 1 1 D S gt 3100 mv a 5 O 10 1 100 uV 1 10 100 mA 1 10 100 1 000 A Thru current lo A r m s omRONn Read and Understand This Catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE
17. aterproof packing onto the Controller Terminal Cover l When two or more Controllers are Waterproof Mounting Bracket E53 COV16 mounted make sure that the surrounding tee Accessory Accessory temperature does not exceed the CCESSO A Z a ji ifi ry Crimp terminal size M3 5 Alowabie oporling temperature specified ooe ESAN omRONn E5AN E5EN ESEN Mounted Separately Group Mounted 48 x number of units 2 5 5 h 79 2 l 450 48 gt F 1 oy ay OMRON i 9288 96 112 120 min i Group mounting does not allow waterproofing ESEN k S t Y gots Terminal Cover Waterproof Mounting Bracket E53 COV16 Packing Accessory Accessory i Accessory Crimp terminal size M3 5 e Recommended panel thickness is 1 to 8 mm e Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications Accessories
18. eater current will be measured when the control output is ON and the output assigned to the alarm 1 function will turn ON if the heater current is lower than the set value i e heater burnout detection current value 32 For SSR failure alarms the heater current will be measured when the control output is OFF and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value i e SSR failure detection current value k3 For heater overcurrent alarms the heater current will be measured when the control output is ON and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value i e heater overcurrent detection current value Electrical Life Expectancy Curve for Relays Reference Values E5AN E5EN 250 VAC 30 VDC resistive load cos 1 0 2 3 4 5 6 Switching current A Note Do not connect a DC load to a Controller with a Long life Relay Output omrRONn E5AN E5EN External Connections e A voltage output control output 1 for driving SSR is not electrically insulated from the internal circuits When using a grounding thermocouple do not connect any of the control output terminals to ground If the control output terminals are connected to ground errors will occur in the measured temperature values as a result of leakage current
19. he set point by setting the alarm ARI Upper and Iowerlimitrange OFF SP sas upper limit H and alarm lower limit L 51 Upper and lower limit with a i eA A standby sequence is added to the upper and standby sequence ge SP lower limit alarm 1 6 x X lim 6 Upper limit with standby sequence _ on zz A standby sequence is added to the upper limit alarm SP SP 2 6 gt Xi X imi 7 Lower limit with standby sequence oN E N a A standby sequence is added to the lower limit alarm SP SP 3 6 nae ON a ON fx The alarm will turn ON if the process value is larger ia g Absolute value upp r limit o a oF o than the alarm value X regardless of the set point 9 Absolute value lower limit ON ON eae The alarm will turn ON if the process value is smaller OFF OFF o than the alarm value X regardless of the set point 10 Absolute value upper limit with ON Ba ON xa A standby sequence is added to the absolute value standby sequence OF QER E upper limit alarm 8 x6 11 Absolute value lower limit with ON r ON x A standby sequence is added to the absolute value standby sequence Oro OFF T lower limit alarm 9 6 12 LBA alarm 1 type only 7 13 PV change rate alarm x8 5 Set value 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps 6 Refer to the ESCN ES5AN E5EN ESGN Digital Temperature Controllers User s Manual Basic Type Cat No H156 for inf
20. must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products e Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog e Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations e Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the prod
21. ormation on the operation of the standby sequence 1 With set values 1 4 and 5 the upper and lower limit values can be set independently for each alarm type and are expressed as Land H 2 Set value 1 Upper and lower limit alarm Case 1 Case 2 Case 3 Always ON L H SP SPL H H SP L eat 37 Refer to the ESCN ESAN ES5EN ESGN Digital Temperature H lt 0 L gt 0 H gt 0 L lt 0 H lt 0 L gt 0 Controllers User s Manual Basic Type Cat No H156 for IHl lt IL IHl gt IL H LSP IH gt ILI information on the loop burnout alarm LBA H gt 0 L lt 0 8 Refer to the ESCN ES5AN E5EN ESGN Digital Temperature SPH L IHl lt IL Controllers User s Manual Basic Type Cat No H156 for 3 Set value 4 Upper and lower limit range information on the PV change rate alarm Case 3 Always OFF H lt 0 L lt 0 Case 1 Case 2 L HSP SPL H H SP L H lt 0 L gt 0 H gt 0 L lt 0 H lt 0 L gt 0 IH lt IL lH gt ILI H LSP IH L H gt 0 L lt 0 SPH L lH lt LI 4 Set value 5 Upper and lower limit with standby sequence For Upper and Lower Limit Alarm Described Above e Case 1 and 2 Always OFF when the upper limit and lower limit hysteresis overlaps e Case 3 Always OFF omRONn E5AN E5EN Characteristics Indication accuracy Thermocouple 0 3 of indicated value or 1 C whichever is greater 1 digit max 1 Platinum resistance thermometer 0 2 of indicated value or 0 8 C whichever is greater 1 digit ma
22. rsal thermocouple Pt inputs Models with temperature inputs e Auto manual switching e Analog current voltage inputs e Temperature Controller Models with analog inputs Meee lt a status display e Three e Simple program function Indication Accuracy Control Output 2 e Control output ON OFF e Thermocouple input 0 3 of PV e Voltage output e Pt input 0 2 of PV for driving SSR e Analog input 0 2 FS e Long life relay output hybrid 4 digit Display count alarm e PV change rate alarm e Models also available with RS 485 or RS 232C communications Sampling Period e 250 ms Control Output 1 e Relay output PF Key e Voltage output for driving SSR Programmable function key e Current output This data sheet is provided as a guideline for selecting products Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product E5CN E5AN E5EN ES5GN Digital Temperature Controllers User s Manual Basic Type Cat No H156 E5CN E5AN E5EN E5GN Digital Temperature Controllers Communications Manual Basic Type Cat No H158 omRON E5AN E5EN Lineup 3 auxiliary outputs 1 control output 2 control outputs 1 control output Analog input 2 control outputs Note Models with one control output or two control outputs can be used for heating cooling control Temperature input 3 auxiliar
23. t flow Approx 7 mA per contact External power supply for ES1B 12 VDC 10 20 mA short circuit protection circuit provided Setting method Digital setting using front panel keys Indication method 11 segment digital display and individual indicators 7 segments displays also possible Character height E5AN PV 15 8 mm SV 9 5 mm MV 6 8 mm E5EN PV 11 8 mm SV 8 1 mm MV 5 8 mm Content of 3 level display PV SV MV PV SV multi SP or soak time remain Number of digits 4 for PV SV and MV Multi SP Up to four set points SPO to SP3 can be saved and selected using event inputs key operations or serial communications Bank switching Not supported Other functions Manual output heating cooling control loop burnout alarm SP ramp other alarm functions heater burnout detection including SSR failure and heater over current detection 40 AT 100 AT MV limiter input digital filter self tuning temperature input shift run stop protection functions control output ON OFF counter extraction of square root MV change rate limit logic operations PV SV status display simple program automatic cooling coefficient adjustment Ambient operating temperature 10 to 55 C with no condensation or icing for 3 year warranty 10 to 50 C Ambient operating humidity 25 to 85 Storage temperature 25 to 65 C with no condensation or icing A 2 level display when
24. tput for driving SSR E5EN Q3MTD W 500 N Current output E5EN C3MTD W 500 N Note Models with analog inputs do not have temperature unit indicators omrRONn E5AN E5EN Option Units Name Function Model ae RS 232C communications E53 EN01 Communications Unit RS 485 communications E53 EN03 Event Input Unit Event inputs E53 AKB Accessories Order Separately USB Serial Conversion Cable Current Transformers CTs Model Hole diameter Model E58 CIFQ1 5 8 dia E54 CT1 12 0 dia E54 CT3 Terminal Cover Connectable models Model CX Thermo Support Software E5AN Model E53 COV16 E5EN EST2 2C MV4 Note The Terminal Cover comes with the E5CN 500 models Waterproof Packing Connectable models Model E5AN Y92S P4 E5EN Y92S P5 Note The Waterproof Packing is included with the Controller OMRON Specifications E5AN E5EN Ratings Power supply voltage No D in model number 100 to 240 VAC 50 60 Hz D in model number 24 VAC 50 60 Hz 24 VDC Operating voltage range 85 to 110 of rated supply voltage Power consumption 100 to 240 VAC 10 VA 24 VAC VDC 5 5 VA 24 VAC 4 W 24 VDC Sensor input Models with temperature inputs Thermocouple K J T E L U N R S B W or PL Il Platinum resistance thermometer Pt100 or JPt100 Infrared temperature sensor 10 to 70 C 60 to 120 C 115 to 165 C or 1
25. ucts may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2011 1 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2011 All Right Reserved
26. x Analog input 0 2 FS 1 digit max CT input 5 FS 1 digit max Transfer output accuracy 0 3 FS max Influence of temperature x2 Influence of voltage 2 Thermocouple input R S B W PL II 41 of PV or 10 C whichever is greater 1 digit max Other thermocouple input 1 of PV or 4 C whichever is greater 1 digit max 3 Platinum resistance thermometer 1 of PV or 2 C whichever is greater 1 digit max Analog input 1 FS 1 digit max Input sampling period 250 ms Hysteresis Models with thermocouple platinum resistance thermometer input universal input 0 1 to 999 9 EU in units of 0 1 EU 4 Models with analog input 0 01 to 99 99 FS in units of 0 01 FS Proportional band P Models with thermocouple platinum resistance thermometer input universal input 0 1 to 999 9 EU in units of 0 1 EU 4 Models with analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 to 3999 s in units of 1 s Derivative time D 0 to 3999 s in units of 1 s 5 Control period 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm setting range 1999 to 9999 decimal point position depends on input type Affect of signal source resistance Thermocouple 0 1 C Q max 100 Q max Platinum resistance thermometer 0 1 C Q max 10 Q max Insulation resistance 20 MQ min at 500 VDC
27. y outputs E5AN E5EN Basic Type Terminal block 3 auxiliary outputs 3 auxiliary outputs Model Number Structure Model Number Legend Controllers Option Units E5AN E5EN _ 3_ ML_ILJ L1 500 N E53 L 1234567 8 9 1 1 Control Output 1 1 Function R Relay output EN01 RS 232C communications Q Voltage output for driving SSR ENO3 RS 485 communications C Current output AKB Event input 2 Auxiliary Outputs 3 Three outputs 3 Heater Burnout SSR Failure Control Output 2 or External Power Supply for ES1B Blank None Q Control output 2 voltage output for driving SSR Y Long life relay output hybrid H Heater burnout SSR failure Heater overcurrent detection CT1 HH Heater burnout SSR failure Heater overcurrent detection CT2 P Power supply for sensor 4 Option M Option Unit can be mounted 5 Input Type T Universal thermocouple platinum resistance thermometer input L Analog current voltage input 6 Power Supply Voltage Blank 100 to 240 VAC D 24 VAC VDC 7 Case Color Blank Black W Silver 8 Terminal Cover 500 With terminal cover 9 Version N Available only to models released after January 2008 Note Estimates can be provided for coatings and other specifications that are not given in the datasheet Ask your OMRON representative for details omRONn Ordering Information E5AN E5EN
Download Pdf Manuals
Related Search
Related Contents
MOEN S6700BN Installation Guide Micro Cornucopia Manual del usuario Modelo 45160 ZyXEL P-630-S User's Manual Descargar Manual del usuario IxP4000 Installation Manual Kwikset REKYG KIT CP SMT KW Installation Guide Copyright © All rights reserved.