Installation & Operating Instructions
Contents
1. DRAFT 24 Jul 2013 In situations where it is not possible to sweep through the stove the installer will have provided alternative means such as a soot door After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush Periods of Prolonged Non Use Ifthe stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensation and subsequent damage leave the air controls fully open Extractor fan There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room Aerosol sprays Do not use an aerosol spray on or near the stove when it is alight Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately Do not relight the stove until the chimney and flueway have been
2. IMPORTANT NOTES General Before lighting the stove check with the installer that the installation work and commissioning checks described above have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Air Controls Manually operated air control can be managed by adjusting the air control valve to increase decrease the air flow to the stove Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Chimney cleaning The chimney should be swept at least twice a year It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation This is a precaution to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove Page 4 of 5
3. e Keep the grates ventilation free of any obstructions 3 7 Safety advice This appliance produces heat and may cause severe burns if touched The stove may still be HOT even when the fire has burnt out KEEP CHILDREN AWAY A FIRE GUARD IS ADVISABLE TO PROTECT CHILDREN THE ELDERLY AND INFIRM 10 Technical manual 1303 Monaco 134 06 05 3 8 Trouble Shooting Problem Fire difficult to start Fire goes out Fire burns too quickly Smokes when lighting up Smokes while burning Low heat output pl Probable causes Wood green or damp Logs are too big Poor quality wood Not enough primary air Insufficient draught H Too much draught Excessive draught Poor quality wood Flue duct is cold Room is in decompression negative pressure Draught is insufficient E Down draught H Room is in decompression H Poor quality wood Poor mixing of the convection air M This sign means that you should ask for a qualified engineer to do the work ACTION Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter To light the fire use small very dry twigs To maintain the fire use split logs Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Open air control Check that the flue is not obstructed sweep it if necessary Seek adv
4. cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not under any circumstances be shut off or sealed USER OPERATING INSTRUCTIONS Please read the important notices given above before referring to the main instruction book for detailed operating instructions Recommended fuels Please note that HETAS Ltd Appliance Approval only covers the use of wood logs on this appliance HETAS Ltd Approval does not cover the use of other fuels either alone or mixed with the recommended fuels listed above nor does it cover instructions for the use of other fuels The stoves have a refuelling interval of 0 75h to achieve the nominal rated output Wood logs should be seasoned with a moisture content of around 20 De Ashing It is important that you empty the ash pan at regular intervals and dispose of ash in a safe and environmentally friendly manner Always use the operating tools provided and replace the ashpit cover correctly DO NOT allow ash to build up underneath the bed as this may cause damage to the grate Spare Parts For more information on obtaining spare parts please contact the manufacturer directly using the contact in the main s
5. hear th super imposed or constructional is suitably delineated to discourage combustible floor finishes from being laid too close to the appliance by marking the edges or providing a change of level Position the appliance on the hearth such that combustible marerial cannot be laid closer to the base of the appliance than a At the front 300 mm if the appliance is an open fire or stove which an when opened be operated as an open fire or 225 mm in any other case b At the back and sides 150 mm or in accordance with the recommendations below which relate to distance from hearth to walls Please refer to section J of the Building regulations When using a single wall flue pipe there must be a clearance A of at least 450 mm from any combustible materials timber mantel girder Technical manual 1303 Monaco 134 06 05 2 3 Mounting the flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm 2 4 Smoke exit on the top Figure 4 The stove is set from the factory with a top outlet Do not remove the cast iron top Remove the cardboard chock from the top A 2 5 Smoke exit at rear Figure 5 Do not remove the cast iron top Remove the cardboard chock from the top Remove the infernal baffle 1 Removed the flue spigot 7 Place the seal rope 3 within the groove fix the blanking plate 4 and the clamp 5 and ens
6. the replacement in our factory of parts recognised as being defective from the outset by our Guarantee Inspection Department Carriage and labour is Name and address of the installer cccccccceeeeeeesseeeenees at the user s cost Moreover if the repair or replacement of parts covered by the guarantee is found to be too costly vis a vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact with high temperatures namely soles and burner grates bottom plates baffles ash pans paintwork and surface treatments for decorative parts Also excluded from this guarantee are seals and glass 3 Any damage which may result from the use of the appliance with a fuel other than that stipulated in our instructions 4 Damage occurring to parts caused by elements outside the appliance down draught storm damage damp abnormal pressure or vacuum heat shocks etc 5 Damage to electrical parts caused by plugging in and using the appliance on a mains system the voltage of which measured at the entrance to the appliance is 10 above or below the nominal voltage of 220 V Exclusion of liabil
7. unida nia 224022 00 228624 00 231304 00 237430 00 259015 00 262614 00 265606 00 265608 00 270402 00 270417 00 300136 RH A LOQus ctasedsisansacdeistiavaanetnasesstaisdacsitesteasssadaiueaiscuasadaias 300136 RP 300136 77 300136 EF 300432 Wood grate Side panel Side panel Side panel s SIDE PANO Ane AS Side panel Sealing Plate vaseiscciccecdssesdessesecectestentedeseeassces Suppl flue baffle Ash pan guide A san kigen pi aaa kra ki kanonik sise on ran nas eaani SE D Y 327909 77 kk ikaa nos ess sasouksni onsi ASW pam OUE ki ai krake o sakado fas na es kan aa sip oo A arrea ainiai nickeden kasii Technical manual 1303 Monaco 134 06 05 exploded view Figure 9 Stove Technical manual 1303 Monaco 134 06 05 Y 1340605 Y P 1340605 P L 1340605 L E 1340605 E J 1340605 J NS Code ci fies tie rien e Qty 42 327909 79 1 42 327909 EF al 43 331116 RH Al 43 331116 RP el 43 331116 77 sl 43 331116 79 al 43 331116 EF al 44 332004 ecen sel 45 352175 AL 45 352175 al 45 352175 deli 45 352175 al 45 352175 wl 46 406816 irse al 47 808001 sal 48 161025 Touch up paint s l 48 161027 Touch up paint al 48 161060 Touch up paint ve 1 48 161061 Touch up paint sl 49 989009 Complete AA kosa s asa ok tie an ss nn as ann s
8. works at is strangest efficiency The more closed down the air slide is the less effective the airwash will be when shut down completely the airwash system can not function The nominal output is obtained with the settings as follows primary air inlet C Closed secondary air inlet B 50 Open Tertiary air inlet Opened It is important to follow theses instructions in order to active clean burning and to maximise the efficiency from the stove Do not leave the fire unattended After on the new charged logs Always refuel on to hot embers Never overload the firebox Always keep the logs below the level of the tertiary air holes 3 3 Operating procedure when using solid mineral fuels smokeless fuels When using smokeless fuels the tertiary air should be closed coal position as the secondary air inlet B The nominal output is obtained with the air settings as follows primary air C 75 opened secondary air B closed tertiary air E closed Technical manual 1303 Monaco 134 06 05 3 5 De ashing Ashes must be removed regularly Ashes must never be allowed to pile up to the grate The grate would not be cool down and could rapidly be damaged Empty the ashes when the appliance is cold Remove the ash drawer using the tool provided Empty the ashes carefully with regard to the live embers 3 3 Maintenance of the Chimney Very important In
9. Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney should be swept several times per year together with the stovepipe connection section If the chimney catches fire you must cut off the flue draught close the doors and windows hatches and keys and call the Fire Brigade without delay DO NOT OPEN THE DOOR OF THE APPLIANCE OR AIR INLET UNDER ANY CIRCUMSTANCES Chimney condition should be checked at least once per year by a professional engineer Technical manual 1303 Monaco 134 06 05 3 Instructions for user The manufacturer will not be responsible for any damage caused to the appliance due to the incorrect use or installation of the appliance e g prohibited fuel use and any alterations made to the appliance which have not been authorised by the manufacturer We recommend that you use only the manufacturer s own brand spare parts Don t run the stove inmild weather with coal Under certain circumstances e g fog and repeated thaw the chimney will not draw sufficiently well and thus be at the origin of asphyxia Awaiting better weather circumstances don t use any coal but only wood At the first lighting the fire must be progressively increased to al
10. Monaco Multi fuel stove BS EN 13240 Model 134 06 05 Nominal output 5 9 kW wood 8 8 kW solid mineral fuels Description of the appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1303 2 25 10 2012 Technical manual to be saved by the user for future reference BOUTIQUES DU FEU Franco Belge Parc d activit s de la Verte Rue All e des Pr les 59270 BAILLEUL T l 03 28 40 32 50 Subject to modifications DRAFT 24 Jul 2013 USER MANUAL FOR STOVES WITHOUT BOILERS SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET TO BE READ IN CONJUNCTION WITH THOSE IN THE INSTRUCTION BOOKLET READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY INSTRUCTIONS CAREFULLY BEFORE INSTALLATION These instructions together with those in the instruction booklet cover the basic principles to ensure the satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byela
11. NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in EN 13384 1 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught BS EN 15287 1 2007 gives additional details The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 230 mm x 230 mm Remedial action should be taken if required seeking expert advice if necessary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then any new system must be to the designation described above and in ac
12. Smoke exit on the top There must be a clearance of at least 150 mm at each side back and sides of the appliance in accordance with the below recommandations from a non combustible wall This distance must be extended to a minimum clearance of 900 mm side and 700 back from any combustible material If any part of the back or sides of the appliance lies within 150 mm horizontally of the wall than the wall should be of solid non combustible construction at least 50 mm thick from level to a level of 200 mm above the top of the appliance and 1200 mm above the hearth Il however any part or sides of the appliance lies within 50 mm of the wall then the wall should be of solid non combustible construction at least 200 mm thick from floor level to a level of 300 mm above the top of the appliance and 1200 mm above the hearth Where the hearth itself in at least 150 mm from an adjacent wall There is no requirement for protection of the wall It should be noted that these thicknesses of solid non combustible material can be substituted by thinner material if the same overall level of protection can be achieved When using a single wall flue pipe there must be a clearance A of at least three times its diameter B from any combustible materials If the appliance has to be located in an opening this distance must be extended to a minimum clearance A of 450 mm from the pipe or the stove body to any combustible materials Hearth The
13. also in the presence of old and or infirm people 3 1 Fuel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Large logs must be split and cut to an useful length before being stored in a sheltered and ventilated place e Recommended fuel The best fuels for use with the Franco Belge Monaco are Seasoned wood hard wood logs that have been cut split and stored for at least two years with a maximum moisture content of 20 e g oak beech elm etc Anthracite dry steam coal fuels as described in type A table B2 of the Standard smokeless fuels such as homefire phurnacite ancit We do not recommend the use of Homefire on your stove due to the number of glass panels which have been effected by this fuel e Prohibited fuel Any form of housecoal bituminous coal or petroleum based fuels We do not allow that unseasoned wood green wood is used due to it s high levels of moisture which will produce tar and in turn can cause the insides of the stove and the lining of the chimney to become coated which in turn could lead to a chimney fire We do not allow recovered wood e g railway sleepers chipboard pallets are burned as these have been treated and will product a great deal of pollution to th
14. an cause serious accidents chimney fires burning of plastic insulation materials in partition walls etc This stove is exempted by DEFRA for burning wood logs in UK Smoke Control Areas SCA DEFRA exemption is dependent upon the appliance being fitted with a mechanical stop to prevent closure of the secondary air control beyond the 25 open position You should check that this stop mechanism is fitted before installation of the stove and certainly before using the stove in a SCA to burn wood logs If the stop mechanism is fitted then the minimum chimney flue diameter can be 125 mm but if the stop mechanism is not fitted then the stove is not exempted and the minimum chimney flue diameter is 150 mm in accordance with Approved Document J of the building regulations The insulation of both the appliance and the exhaust gas pipe has to be reinforced and done according to the Standards and the Building Regulations for safety reasons The installation must be carried out according to the Standards and the Building Regulations Failure to respect the manufacturer s instructions will invalidate the warranty The manufacturer s responsibility shall be limited to the supply of the appliance 2 2 Location of the unit with a nat
15. appliance must stand on a fireproof hearth It is possible to provide a hearth made of non combusible board sheet material or tiles at least 12 mm thick C Constructional hearths should be constructed of solid non combustible material at least 125 mm thick including the thickness of any non combustible floor under the hearth The hearth must Flue baffle Back panel Gasket Blanking plate 5 Clamp 6 Gasket 7 Flue collar hunda Figure 5 Smoke exit at rear protrude at least 300 mm in front of the stove and 150 mm each side Hearths are provided to prevent combustion appliances setting fire to the building fabric and furnishings and to limit the risk of people being accidentally burnt Therefore they should be separated from adjacent combustible materials and should be satisfactorily delineated from surrounding floor finishes carpets etc as follows Combustible material should not be placed under a constructional hearth for a solid fuel appliance within a vertical distance of 250 mm from the upper surface of the hearth unless there is an airspace of at least 50 mm between the combustible material and the underside of the hearth Where a superimposed hearth has been placed onto a constructional hearth combustible material placed on or besid the constructional hearth should not extend under the superimposed hearth by more than 25 mm or closer to the appliance than 150 mm Ensure that the
16. arby obstacles then an anti down draught cowl must be installed on the chimney or the chimney height must be increased e If the chimney draught is excessive or irregular a draught stabilizer barometric damper must be installed to the connector pipe it must be visible and accessible Chimney to be built New flue The chimney 1 Chimney 2 Funnel shape fireproof material 3 Non combustible plate 4 Access to cleaning 5 Insulation 6 Plate not removable and ventilated air Figure 6 Chimney connector Technical manual 1303 Monaco 134 06 05 must comply with Current Building Regulations If in doubt consult your Dealer or local Building Inspector e The appliance must not support the weight of the flue e It must be distant from any combustible material walls cross members e It must permit easy sweeping 2 7 Chimney connector e The connection to the flue must
17. be carried out according to local building regulations e The appliance must be installed as close as possible to the chimney e Any connection pipe must be suitable for use with solid fuel burning appliances in accordance with Approved Document J of the building regulations e The connecting pipe must not reduce in diameter at any point to less than the diameter of the outlet of the stove e The connection can be either vertical or horizontal For horizontal connections avoid right angle bends e The join between the connection pipe and the stovepipe and the flue must be leak tight e For the premises equipped with a mechanical controlled ventilation the airtightness has to prevent the exhauster drawing out the smokes from the exhaust gas pipe e The connection pipe and any draught stabiliser must have access for cleaning 2 Cam 1 Pressure screw Figure 7 Adjusting of the door closing pressure 2 8 Door closing pressure Figure 7 The closing latch rotates around a pressure screw positioned cam Loosen pressure screw 1 Turn cam to desired position 2 Tighten pressure screw 1 2 9 Pre utilisation check Check that the seals of the smoke line are in good condition Check that the door closes correctly Check that the glass is not damaged Check that the smoke passages are not obstructed by packaging or removable parts Check that all removable parts are correctly installed 2 10 Maintenance of the
18. chimney if the chimney is not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible hearth of a size and construction that is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions If the stove is to be installed on a combustible floor surface it must be covered with a non combustible material at least 12mm thick in accordance with Building Regulations Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber Combustion air supply In order for the stove to perform efficiently and safely there must be an adequate air supply into the room in which the stove is installed to provide combustion air The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J Special attention should be taken in newer build properties where the design air permeability is less than 5m h m Approved Document J gives more information on this An opening window is not appropriate for this purpose The fitting of an external air kit dire
19. cordance with Building Regulations Approved Document J A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for use as the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove Any bend in the chimney or connecting fluepipe should not exceed 45 90 bends should not be used Combustible material should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted Fitting of a draught stabiliser will affect the requirement for the permanent air supply into the room in which the stove is fitted in accordance with Approved Document J see also combustion air supply Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe where it is not intended for the chimney to be swept through the appliance Page 2 of 5 DRAFT 24 Jul 2013 Hearth The hearth should be level and able to accommodate the weight of the stove and its
20. ct to outside air must not be considered substitute for installing the appliance with a permanently open air vent in compliance with ventilation requirements stated in Approved Document J Please reference ADJ for further guidance Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney in accordance with their instructions In some cases it may be necessary to fit an adaptor to increase the diameter of the flue to the minimum required 150 mm section of the chimney or liner All joints in the connection between the stove and the chimney must be made gastight using fire cement and where necessary fire proof rope infill Means should be made for sweeping the entire length of the flue be that through the appliance or by suitable sweeping hatch in the flue Commissioning and handover Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire check all seals for soundness and check that the flue is functioning correctly and that all products of combustion are vented safely to atmosphere via the chimney terminal On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensur
21. e environment and will overheat the appliance 3 2 Instruction for use with Wood Figure 8 3 2 1 Lighting Set all air controls to the maximum opening Use a double handful of kindling and light the fire with chemical firelighters with the door 5 10 mm ajar After several minutes the flames from the firebed are diminishing add 2 half sized logs and keep the door ajar and the air controls unaltered About 12 minutes from the Start when the logs are well alight but flames Start receding add 2 full sized logs and leave the controls as before After a further 3 mn close the door wait for another 3 mn and close the primary air C until the logs burn down to embers reload a this point and adjust the settings to the desired positions Never use firelighters under liquid forms as they may lead do severe safety issues 3 2 2 Refuelling procedure The appliance must function with the door property closed the burning rate beign controlled in using the secondary air flap B Experience will show you which settings are best for your situation Before refuelling set the secondary air B to the required setting open at maximum the primary air C load the Wood and wait for 3 or 4 minutes After This period when the fuel logs are well blackened and the flances well established close the primary air The airwash system works with the top airslide secondary air inlet B When the top airslide is fully opened the system
22. e to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons HETAS Ltd Approval These appliances have been approved by HETAS Lid as an intermittent operating appliance for burning wood logs only Page 3 of 5 DRAFT 24 Jul 2013 USER MANUAL FOR STOVES WITHOUT BOILERS SUPPLEMENTARY OPERATING INSTRUCTIONS FOR THE UK MARKET TO BE READ IN CONJUNCTION WITH THOSE IN THE INSTRUCTION BOOKLET WARNING NOTE Properly installed operated and maintained this stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean at all times
23. ice from a chimney specialist Partially close the top air control Install a draught stabiliser to the connector pipe Consult your Dealer Do not continuously burn small wood sticks bundles carpentry offcuts plywood pallets etc Burn paper and kindling wood to increase heat In houses equipped with mechanical ventilation partly open a window until the fire is well established Consult a chimney specialist Check that the flue is not obstructed sweep if necessary Install an anti down draught cowl Consult your Dealer In houses equipped with Mechanical Ventilation partly open a window until the fire is well established Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Check the air flow system air inlet piping air outlet Check that the next rooms are equiped with ventilation grids to help out the hot air circulation Technical manual 1303 11 Monaco 134 06 05 4 Spare parts When ordering spare parts specify the stove type and serial number including the colour index on the guarantee or identification plate the name of the part and the part number Example Wood stove Monaco ref 134 06 05 color P top plate 352175 RH zZ o 0WO0XJO0UuAau0NA Y 1340605 Y P 1340605 P L 1340605 L E 1340605 E J 1340605 J 100917 100939 Firebrick Firebrick s ks GASKOL
24. ity In the case of a product manufactured at the client s request under no ci rcumstances may we as a subcontractor be considered liable vis a vis the client or third parties for defects arising from the installation or a design fault with the item in question 134 06 05 Model of the appliance Color Y P e This certificate has to be completed and kept carefully In case of claims send a copy of this to FRANCO BELGE BOUTIQUES DU FEU Parc d activit s de la Verte Rue All e des Pr les 59270 BAILLEUL FRANCE
25. low the various parts to expand normally and to dry up Note When the fire is lit for the first time the stove may give off fumes from the new paint This is normal but ensure the room is well ventilated during the first few hours of operation Warning properly installed and operated this appliance will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is dangerous and must not be tolerated If fume emission does persist Open doors and windows to ventilate room Let the fire go out and dispose of fuel from the appliance A Opening closing the main door B Secondary air inlet B1 opened B2 closed C Primary air inlet Opened Closed Handle Tertiary air inlet mu We recommend that the wooden operating handle is removed from the door immediately After use and set aside due to the fact that Wood is a combustible material The Woodenhandle should never be left on a lit appliance E Closed Opened Coal Wood lt p o Do Figure 8 Operating devices Technical manual 1303 Monaco 134 06 05 Check for flue or chimney blockage and clean if required Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in the presence of children and
26. maintenance of the appliance and chimney system HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Page 1 of 5 DRAFT 24 Jul 2013 Metal Paris When installing or servicing this stove care should be taken to avoid the possibility of personal injury STOVE PERFORMANCE Refer to the manufacturer s main instruction manual for details of the stove s performance PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room Chimney In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke problems into the room
27. order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney should be swept several times per year together with the stovepipe connection section If the chimney catches fire you must cut off the flue draught close the doors and windows hatches and keys and call the Fire Brigade without delay DO NOT OPEN THE DOOR OF THE APPLIANCE OR AIR INLET UNDER ANY CIRCUMSTANCES The chimney must be serviced and cleaned by a specialist 3 6 Maintenance of the stove e The appliance must be cleaned regularly together with the connecting pipe and the flue pipe e Open the door and remove all deposits in the firebox and clean the removable fire grate e Cleaning of the glass door can be done with a soft cloth dampened with water and vinegar or potassium this must be done when the appliance is cold then rinse with clear water Do not use abrasive cleaners e The vitroceramic glass will resists to temperatures of up to 750 C Should the glass break due to misuse it must be replaced by the manufacturer own product e All the casing parts can be cleaned using a soft cloth either dry or slightly damp In case of condensation or water splashes clean the parts before they dry out e Check that there are no obstructions before relighting after a long period of disuse e The appliance must not be used with a flue serving several appliances
28. ous 1 14 Technical manual 1303 Monaco 134 06 05 Notes Technical manual 1303 15 Wi FRANCO BELGE jij Guarantee certificate Legal guarantee The specifications dimensions and information shown on our documents are provided for information purposes only and under no circumstances are binding upon the vendor With the aim of constantly improving our equipment all modifications considered as necessary by our departments may be made without notice The provisions of the present guarantee certificate are not excluding or limiting the owner of the equipment s rights concerning the legal guarantee regarding faults or hidden vices which applies in all circumstances in the conditions detailed in articles 1641 and following of the civil code and in the country in which the equipment was purchased Contractual guarantee Our equipment is guaranteed against faults and hidden vices subject to the following conditions 1 Installation and adjustment of the device by a professional installer 2 Observance of the instructions provided in our technical documents and our installation adjustment instructions 3 The installation use and maintenance of the device carried out in conformity with the applicable standards and legislation and with the indications provided in the technical instructions accompanying the device This guarantee covers
29. snaninana na p 5 Maintenance of the chimney p 7 Instructions TOF USER uc aa p 8 PU ori vn p 9 D ASKINQ ciaci n p 9 Instruction for Use With WOOQ rererrrroes p 9 Maintenance of the chimney p 10 Refuelling procedure cccccccooocccononononnanononnnnnns p 9 Maintenance of the StOVE vrrreeererirrrennnns p 10 Operating procedure Safety advice iniv sekans sri e vis nada p 10 when using solid mineral fuels p 9 Trouble shooting omoococonnncnnicncnnnnnnninenonnnos p 11 SSP ANS ANUS petet tenten e eten d denie us ace on a ce anes Ces e sane eee ea ae eke esse an p 12 Technical manual 1303 Monaco 134 06 05 This appliance is meant to burn wood safely WARNING Incorrectly installed this appliance can be dangerous and possibly cause serious accidents We recommend that you engage the services of a professional engineer for its installation and the regular maintenance requirements 1 Product information 1 1 Package PERFORMANCE WITH MINERAL SOLID FUELS smokeless fuels e 1 package stove Nominal heat output 8 8 Efficiency net 70 6 1 2 General characteristics Co 13 02 0 15 Mean flue gas temperature 374 Flue gas mass flow 5 8 Reference Nominal heat output 5 9 Chimney draft required 12 Authorised fuels under section 20 of the clean air act Hearth dimensions 1 3 Appliance description nee Multifuel stove in conformity with BS EN 13240 240 e Intermi
30. tove brochure Page 5 of 5 Monaco 134 06 05 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality of its appliances and is committed to meet its customers needs FRANCO BELGE which can boast a 80 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of products This document contains instructions on how to install your appliance and make full use of its functions both for your comfort and safety CONTENTS BfOdUCE NTOFNMATON 5 ii ase e kn n pa ee ik set Dwe a ages Sh pew pk Ok dle ap a BS DY p 3 PACKAGE wesc ina a kaka ak ai pa kk akse kaka k cba kan sasa kan p 3 Appliance descriptiON rrrrrrrererenonnons p 3 General characteriStiCS rrrrrerononns p 3 Operating principle rrrrrririrrrrrereretenmns p 3 Installation Instructions sing antes koka ec pa dog sha deandseeen sie dacauesiuayasesunaveacundecsesanenendes p 4 Warning to the USEY cceeeeeeeeeeeeeeeeeeeeeeeee p 4 FI pa ki ak aaa epa ka aide in p 5 Location of the UNIt rlrrrrereeeeererananasnonn p 4 Chimney CONNECOF iuioeeorrrrriritiritattrtnnnnnn p 6 Mounting the flue collar ssassn p 5 Door closing Pressure ccccccccccccnnnnnnoninannnnnnnos p 6 Smoke exit on the tOP rrrrrrrrrerrererenons p 5 Pre utilisation CHECK urrrreeeeereraranasnnnons p 7 Smoke exit at rear incn
31. ttent burning heating appliance 225 e Detachable flue spigot for rear or top chimney connection e Front loading door fitted with large refractory glass panel e Adjustable primary air for controlling the burning rate e Large ash pan Log dimensions lenght maxi 40 Ash pan capacity 2 2 90 1 4 Operating principle PEREORMANCE WITH WOOD The MONACO is designed for operation with the door au e is designe emaency met closed Heat is mainly diffused by radiation through the Co 13 02 window and body of the appliance Mean flue gas temperature Combustion occurs on the grate with draught entry through Flue gas mass flow the top of the combustion chamber when using wood and under the grate when using smokeless fuels 388 141 9139 g125 Figure 1 Dimensions in mm a H g 1 TH 433 Technical manual 1303 3 Monaco 134 06 05 2 Installation instructions 2 1 Warning to the user All the local and national regulations and in particular those relating to national and European standards must be observed when installing the appliance An incorrectly installed heating appliance c
32. ural draught check that sufficient air for combustion is available in the room In houses equipped with one VMC controlled mechanical ventilation this one aspire and renew the ambient air in this case the residence is under slight low pressure and a non sealable external air intake must be installed in addition to the chimney itself at least 50cm in section Position of the unit For new installations select a central position within the house to provide a good heat distribution around the building The heat distribution towards the other rooms will be made through the communicating doors These rooms must be at low pressure or fitted with non adjustable air registers placed so that they cannot be obstructed to encourage circulation of the hot air Floor and walls make sure there are not combustible or covered with non combustible material Otherwise it must be necessary to install a non combustible protection not less than 75 mm a not less than 200 mm not less than 300 mm than 300 mm not less han not less han 1200 mm 1200 mm less than Figure 2 Smoke exit on the top Ventilation For satisfactory appliance operation i EJ 150 150 gt EJ 150 150 Figure 3 Minimum clearances 4 Technical manual 1303 Monaco 134 06 05 Figure 4
33. ure a good tightness Place the seal rope 6 within the groove screw into position the spigot 7 and ensure a good tightness Refit the flue baffle 1 2 6 Flue Existing flue The chimney must comply with Current Building Regulations If in doubt consult your Dealer or local Building Inspector e The flue must be in good condition and must provide sufficient draught refer to technical details p 3 e The flue must be suitable for the installation of fuel burning appliances otherwise it must necessary to install a tubing e The flue must be clean It should be swept to remove soot and dislodge tar deposits e The flue must be well insulated If the flue inner wall surfaces are cold a good thermal draw is impossible causing condensation problems tar formation etc to occur e The flue must be watertight e The flue must not be shared with other appliances e The chimney must have a constant cross section e When the cross section of the chimney is too large it has difficulties in obtaining a good draught e The chimney must be at least 4 5 m 15 ft high and be at 40 cm above the ridge of the roof and 8 meters away from any construction e In case of a flat roof or when the roof gradient is lower than 15 the stack must be 1 2 m 4 feet high at least e The capping must not restrain the draught e If the chimney has any down draught tendency due to its position in relation to ne
34. ws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J Should any conflict apply between these instructions and the original manufacturers instructions then the most stringent advice must apply Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www hetas co uk CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and