Home

user manual

image

Contents

1. wasted and therefore results in savings on electricity bills In addition E Eyes also allows for remote control over a TCP IP network without the need for an expensive SNMP card Easy System Monitoring and Tracking Users are able to customize various E Eyes controls such as warning method and alarm messages Features UPS monitoring utility Scheduled system shutdown Graphic display of UPS status e Warning notification via e mail and pager Customized controls User definable warnings Multi language versions Easy to use user interface UPS TROUBLESHOOTING Please check the following solutions if you have any problem on the UPS Make sure the UPS plug is plugged in the outlet correctly Make sure the AC power is in the range of the rated Check the fuse in the rear panel is molten down Make sure the load capacity is within the rated range When you call for service please provide those information s UPS model Serial number Breakdown Date Details about the Status of the UPS
2. NS CAUTIONS UPS is built in potential high voltage Do not remove the case by yourself to get hurt Contact us or reseller if you have any question Do not pill any liquid on the Unit or inside the Unit Avoid putting the UPS near high humidity environment or near liquid such as water chemical solution Avoid putting the UPS where it will be exposed to direct sunlight or any heat surroundings Keeping the hot holes smoothly to release the heart in UPS Using grounding input power cable to connect UPS Do not use UPS on laser Printer because of the high start up current Do not use the UPS outlets on house electric equipment such as hair dryer air conditioner and refrigerator REPLACEMENT AND MAINTENANCE OF THE BATTERY Checking the quantity and the model number before replacing the battery Do not replace the battery by yourself please call the professional people to do it While you are processing the battery keep away fire to avoid explosion Do not open or damage the case of the battery because it contains toxic electrolyte that could be harmful your skin or eyes There are high voltage and current with in the battery Please place it out of children reach 3 6 Maintaining the Battery If you do not use the UPS for long period of time please recharge the battery over 12 hours every 3 months GETTING STARTED Unpacking Your UPS Unpacking the UPS to check if the product is damaged if you find any damag
3. UPS 600VA 1000VA USER S GUIDE INTRODUC TION rrii vaus scans vation tariededsceonecuensaeeeadessaeacesse FEATURES sneons SAFETY INSTRUCTIONS GETTING STARTED THE DISPLAY PANEL SPECIFICATIONS SOFTWARE INSTALLATION vissssenscseswesedvaveissesindsieesvewsncseenenaseans s ta UPS TROUBLESHOOTING INTRODUCTION x Thanks for buying one of these UPS Series This Guide can use on E 600VA 1000VA x Reading this USER S GUIDE first before you start x Attached Warranty Card that service person can keep record of the UPS s status UPS Uninterruptible Power Supply Series Introduction All UPS insist the quality on all of products which is designed for PC and other peripherals only Our UPS S have various kinds of capacity for each equipment These Series are compact low noise and easy to use UPS which can solve different power problems They provide stable clean power and prevent data loss caused by outages and brownouts FEATURES SELF TEST Self test each time switched on When UPS is turned on it makes self test to provide a reliable operation and prevent any damage caused BATTERY PROTECTION Auto self test and discharge protection DC START CAPABILITY The UPS can be activated without utility power UPS POWER SUPPLIED OUTLETS Line Interactive UPS AVR Allows 75 to 125 input voltage range best protection for computer equipment With AVR function boost amp buck UPS
4. e call the vendor Installing UPS Make sure the AC power voltage is identical with the voltage in the rear panel of the UPS Press ON TEST switch the Green light ON that means AC power goes into the UPS Connect the power strip on the computer or other peripherals to the outlets on the UPS Then turn on the computer and then unplug the I P power cord on the UPS to test the operation of the UPS Turning on the UPS to recharge for 8 hours before using it That can recharge the battery You can also use it before you recharge completely but the back up time will be shorter than the full battery capacity To turn off the UPS please press ON TEST switch until the LED light is OFF Do not use UPS on Laser because of the high start up current THE DISPLAY PANEL The Front Panel POWER GREEN LED RED LED The Rear Panel __ RJ11 COMMUNICATION e PORT UPS PROTECTION lt H gt RJ45 MODEM NETWORK OUTLETS PROTECTION SPECIFICATIONS Model 600VA 1000VA Input Volts Range on line 110V 80V 140V 220V 160V 280V Input Frequency 50 OR 60 3HZ AVR Output Volts Range 110V OUT 110V 10 220V OUT 220V 10 Output Volts On Battery 110VAC 10 220VAC 10 Output Frequency On 50 OR 60 1HZ Battery Battery Run Time 10 30 MIN Typical Battery Charge Rated 4hrs to 90 of full capacity Battery Protection Auto self test and Discharge protection Self Test Self test each time switched on Transfer T
5. ime 2 4ms Jouttts USA 2 or IEC 2 Aiaihie Alani Battery back up Slow beeping 10 Seconds Battery Low or Overload Rapid beeping 1second Indicators Green LED On Line Back up slash Red LED Overload Battery Fault Interface RS 232 Ambient Operating 0 40 C 0 95 Humidity Non condensing Storage 15 C 45 C Audible Noise lt 40DBA 1 Meter from surface De Start Yes Surge Energy Rating 240 Joules Back up mode 100 shut down In AC mode 110 alarms No shut down Electrical Protection Automatic cut off on short circuit and input circuit fuse Modem Network Protection Rj45 8Wire One in One out option for modem or network Conformance Applicable Dimensions mm L x W x H 270 x 100 x 190 SOFTWAVE INSTALLATION Introduction E Eyes is a unique uninterruptible power supply UPS software that offers you unprecedented convenience for the control of any UPS Benefits Early Warning System E Eyes can send warning messages via e mail or over the LAN Thus providing an early warning system for power failures system shutdown and a variety of other scenarios It guarantees a faster response time even when you are not in the office Saves files before shutdown occurs No more lost work due to unexpected system shutdown When power failure occurs E Eyes saves all open files before gracefully shutting down the system Cost Savings E Eyes shutdown and startup scheduling function reduces the amount of power
6. provides a stable power to the loads as the input voltage fluctuates ELECTRICAL PROTECTION Automatic cut off on short circuit or Input Circuit Fuse If UPS is overload this circuit Fuse will trip to disconnect the unit from utility power MODEM NETWORK PROTECTION RJ45 JACK option Simultaneous protection for network telephone fax amp modem AUDIBLE ALARM Battery Back up slow beeping 10 seconds Battery Low and Overload or AC Overload Rapid beeping 1 Second INTERFACE AND SOFTWARE RS 232 Interface Software for MS Win98 ME 2000 XP Novell and Linux CPU MICRO PROCESS CONTROL USE WITH STABILITY WIA Mm a m 2 GREEN FUNCTION If the battery is discharging under no load will shut down automatically to keep the span life of battery FULL TIME SURGE PROTECTION The power coming from the wall outlet may damage your equipment by the bad quality power but full time Surge protection intercepts deadly electrical spike and prevents hardware damage EMI RFI FILTERING The power coming from the wall outlet may damage your equipment by electromagnetic or radio frequency interference UPS intercepts the interference by inductor and capacitor and provides clean power INDICATOR aw POWER amp CHARGE GREEN LIGHT ON S gt BACK UP GREEN LIGHT FLASHING D O RED LIGHT ON amp AUDIBLE ALARM DISPLAY BEFORE ZSOVER LOAD UPS SHUTDOWN AUTOMATICALLY E EOK BATT RED LIGHT ON WHEN BATT FAULT SAFETY INSTRUCTIO

Download Pdf Manuals

image

Related Search

Related Contents

DS DSN English and Spanish  USER MANUAL - jb connexions  4thEye Professional 逆引きガイド  be.ez LaRobe Moorea 11" MacBook Air  800  6008.801 Instructions d`installation  Master Price List (Spanish 6-29-2011)    Brinly-Hardy Lawn Mower Accessory 18 BH User's Manual  Termocamere per applicazioni marittime  

Copyright © All rights reserved.
Failed to retrieve file