Home

HIFI Observers` Manual

image

Contents

1. pa ey elo fea pepe ye Pee 0 be i Cc ee E L 576 250 576 255 576 260 576 265 576 270 576 275 576 280 576 285 576 290 usbfrequency GHz Figure 5 1 Multi epoch observations of the water line in the source LDN1157 B1 taken over a period of more than 6 months 5 4 5 3 Solar System Object Frequency Measurements 5 4 6 Observations of Comet Wild 2 were checked against the predictions of the Horizons ephemeris The Herschel centric Wild 2 apparent radial velocities were queried and interpolated to the time of ob servation The pipelined datea at Level 2 has s frequency axis that is affected by the issues listed above but within HIPE one can easily use Horizons to predict the IF frequency of detection using an appropriate spacecraft ephemeris The water lines are found to be within at worst 0 5 MHz of the predicted frequency Spurious Responses in HIFI HIFI like all heterodyne receivers suffers from spurious responses These typically have their origin in the local oscillator source unit where the local oscillator signal is generated but this is not universally the case These spurs can significantly degrade the quality of spectra and therefore it has been prudent to track and catalog these features in all HIFI data taken since pre launch This catalog has been implemented in HSpot so Users can be warned if they tune the LO near the position of known spurs This is illustrated in Figure 5 2 wh
2. I Feri a T T E NY oF N sE hS TE WY 6E QQ x sE NE SS Ei SS na y E p EE A oE eS ae i oe es oe eee er ee pe thn a Bh lh LEN ap hh E E E 576 254 58 576 260 576 262 576 264 576 266 576 268 576 270 576 272 576 274 576 276 576 278 576 280 usbfrequency GHz TOH TeV an V 2H DV Figure 5 8 H and V profiles for obsids 1342181160 1342190184 and 1342192229 towards LDN1157 B1 scaled so line peaks match There are several things to note from Figure 5 8 e The polarisation discrepancy in the wing is in the opposite sense for 160 and 184 e As the observations were performed 6 months apart this could imply that there is some bright region of the outflow contributing to the profile mismatch rather than an intrinsic polarisation effect It can be seen that the profile discrepancy has reduced with successive observations from approaching 30 in 160 to 10 in 184 until in 229 there is a difference in profile in the wing of only 4 see Figure 5 9 e 184 has a lower noise goal resolution than 160 while 229 is free from emission in chop positions aid AA A SA GAS Bs GA A Aaah a ee 1 0 4 ose J X o6 E 4 SOI J H gat 5 J oe 04H 4 al E a a I a Lae pa 0 0 A ae e R Se As Se Se el OR em LAP aL ra EA TE as es es 7 ia ae MTT a 576 262 576 264 576 266 576 268 576 270 576 272 576 274 576 276 576 2718 576 280 576 282 576 284 usbfrequency GH
3. X are minutes po Y are minutes po Position Angle po Nyquist sampling fon Distance between scans arcseconds feo Reference Position Specifications Type By offset By position RA offset aromin po o oS Dec offset aremins Jog RA degrees fu tst S O O O Dec degrees poo i SWt Choose Position Cancel Figure 6 12 HIFI mapping mode selection Here the On the Fly scan mapping tab has been selected to show the options for the mode setup For either mapping setup the user requests an area of sky to be covered the sampling e g Nyquist sampling and an OFF reference position The window for the raster map setting is shown in Fig ure 6 13 80 Using HSpot to Create HIFI Observations gt Observing Mode Settings xj Observing Mode Settings Select a mapping mode OTF mapping wiload chop OTF mapping wi Frequency Switch DBS Cross Mao No mode selected On The Fly mapping 7 DBS Raster Mapping DBS Raster Mapping X are minutes po Y are minutes po Position Angle po Nyquist sampling fon z Distance between scans arcseconds peso Fast Chop Selected jor z Stability Optimisation for Continuum jor z Cancel Figure 6 13 HIFI raster map setup 6 2 2 HIFI Spectral Scan AOT 6 2 2 1 Setting up the Spectrometers and LO Frequencies For the Scan The HIFI spe
4. 5 6 1 tios Currently the HIFI pipeline assumes a side band gain ratio of 1 or normalized value of 0 5 as compared to the figure IF Spectrum Repeatability Sideband Line Ra Specific tests have been carried out in the laboratory and on orbit since the start of the Herschel mis sion to assess the repeatability of spectral lines occurring at different IF frequencies in both upper and lower sidebands On orbit these tests have been done so far in beam splitter Bands 1b 2a and 5a and diplexer Band 4a towards NGC7538 IRS 1 using strong CO lines The frequency was gradually changed so the line was stepped across the band to look for changes in intensity Figure 5 17 shows how this looks in the Band 1b engineering test with all 15 spectra of the same CO 5 4 line over plotted in IF frequency in the upper sideband of the WBS V Figure 5 18 shows a similar example taken from a different source using a standard Spectral Scan in 1b on the H2O 110 101 557 GHz line All of the tests were done in DBS mode The line signal is typically 10 20K and noise less than 0 2K resulting in a S N ratio of over 100 1342190189 WBS V 1b second_spectra_after_LO_change Ta EE RL RT REE flux K ooF ae ee I as Se LN a 4000 re CR SR VCR CA ce YE CC A ss 4500 5000 5500 6000 6500 7000 7500
5. There are four modes provided for observing point sources with HIFI The best mode to choose de pends on the kind of science being done and the situation of the target object For example a point source well away from any diffuse cloud emission is likely to be best suited by a Dual Beam Switch observation where reference OFF source positions are taken close to the target object However sources embedded within molecular clouds the use of a sky source for reference may not be possible and an internal reference is better to use e g a load chop observation In this section we describe the point source modes available for HIFI observations and indicate typical situations in which a given point source mode may be chosen Mode I 1 Position Switch Purpose Used to observe a point source fixed or moving in one or more spectral lines within a single IF band Allows the choice of a reference sky position within 2 degrees of the target Description This is the simplest Observing Mode for HIFI in which the single pixel beam of the telescope is pointed alternately at a target ON position then a reference sky OFF position Observing is done 28 Observing with HIFI at a single LO frequency at the spectral resolution of the chosen back end spectrometer Data taken at the OFF position provide the underlying system background that is removed in pipeline processing by a simple subtraction The OFF position is chosen by the user to
6. gt e g here Time see Figure 6 24 ia the second pulldown menu elect whether your resolution settings will be given in MHz or km s S v Select the resolution of the observations goal resolution and the highest resolution for which the data is likely to be used To do this click on the appropriate cell in the time estimator table and type in the value s wanted Since we have selected a time goal also fill in the time cell with e g 360 sec This completes the time estimator setup Observation Estimates the requested time at present the default is 180 seconds CARECKES OK We have now completed our AOR To get an accurate time estimate for our request click on the Observation AOR window Estimates button in the pointed gt the HIFI Observation Breakdown pops up with the results which includes the expected noise level and total observatory time cost for the request Use the Show sequence parameters which indicates how the observation will be sequenced and or Show message button which also provides a breakdown of time taken for each slew and calibration Ise the results look tine CLick on OR If the results are not to your liking noise then open up the time estimator window again be spent on the observation Repeat as often version overwrites the previous one in the HIFI pointed AOR window not of sufficient level and adjust the time to
7. Observation Est Add Comments Visibility Figure 6 2 HIFI pointed observation AOT window 6 2 1 1 Setting Up the Spectrometers to Use in Pointed and Map ping Observation Requests The initial choice that the user needs to make is the mixer band that contains the frequency around which observations are to be made The pulldown menu under Band on the top left of the Instrument Settings section of either the HIFI Pointed or Mapping AOT pages allows this choice The frequency range for the chosen band is displayed automatically below see Figure 6 3 74 Using HSpot to Create HIFI Observations Mixer settings Mixer band la ow Low limit GHz 488 1 i High limit GHz 551 3 Figure 6 3 HIFI mixer band selection Since HIFI has very high spectral resolution typically less than 1 km s by default the relative motion between the spacecraft and the object being observed needs to be taken into account A redshift or optical radio radial velocity can be input as part of the Instrument Settings section of the Pointed or Mapping AOT page see Figure 6 4 Use the pulldown menus to indicate the type of redshift and the frame of reference being used This will later alter the frequencies of the setup so that the wanted spectral lines appear where they should within the spectrometer Redshift selection Radial velocity redshift a Redshift o 000000 Frame LSR wl Figure 6 4 HIFI redshift
8. PEEM _ i i source position F OED FFE FT N A E G RME mMEADAN 3a i E Tuning of the instrument Ki Zero and comb integration j I Integration on hot load at w I Integration on hot load at v I Integration on cold load at v I Integration on cold load atv initial position L Integration on sky at v I Integration on sky at v Figure 4 5 Timeline for HIFI Frequency Switch observations General Usage Sources with relatively simple spectra either extended or located in complex environments such that region free of emission at the selected LO frequency cannot be defined with either 2 degrees for position switching or 3 arc minutes for DBS Observations of giant HII regions and molecular clouds in Galactic star forming regions may rely extensively on this mode This mode is not recommended in HEB Bands 6 and 7 due to poor stability in terms of baseline shapes ripples and artefacts that may not be treatable in IA such that S N goals set by the User in HSpot can ever be achieved and may thus compromise the intended science goals At this time the recommendation is to use the alternative Load Chop mode in the HEB bands Advantages A potentially very efficient mode with the science target lines almost always being integrated on during the observation and low dead time expected for retuning the LO repeatedly between requested and offset frequencies Expected to be good for baseline characterisation and removal i
9. e Band la Weak spur at 542 3 GHz e Band 1b No spur activity e Band 2a Spurs at 700 0 GHz and 712 0 718 0 GHz e Band 2b Spurs at 772 0 GHz and 776 0 788 0 GHz e Band 3a Spur at 823 0 GHz e Band 3b Spurs between 868 0 876 0 GHz and 952 0 954 0 GHz e Band 4a Spur at 967 0 GHz and 1001 0 1003 0 GHz and 1017 0 GHz e Band 4b Spur between 1090 1108 GHz e Band 5a Spurs between 1134 1136 GHz from OD641 13 February 2011 e Band 6a Spur at 1544 0 GHz 57 HIFI Calibration Band 6b 7a 7b No firm conclusions yet 5 4 6 5 Spectral Purity There are several frequencies in HIFI where the Local Oscillator has been shown to produce more than one frequency In these cases an observed spectrum will have some or all of the features from a different unknown and possibly unstable other frequency When this is the case the mixer gain at the desired frequency will be unknown and it will not usually be possible to calibrate the flux accurately Most of the impure regions were fixed in the ILT TV TB and CoP test campaigns however several frequencies remain to be addressed or cannot be addressed due to hardware safety considerations The known impure frequencies include Band 1a For data taken before OD474 LO frequencies above 550 GHz extreme upper end of tuning range Band 2a LO frequencies above 714 GHz extreme upper end of tuning range Band 3b LO frequencies near 1GHz 941 and 952 GHz Band 4b LO fre
10. flat baseline on either sides of the observed lines see Figure 6 33 ms Clkakele OU On the Frequencies window click Done Observing mode setting Click the set the mapping mode button Select On The Fly mapping tab Fill in map parameters tr DC SB ek Y 3 arcmin NOTE Map sizes much larger than this take too long for a single observation when Nyquist sampling is used at the highest frequencies which have the smallest beam sizes on the sky P A 170 deg this is measured toward the east from north Nyquist sampling On For these observations we HAVE to select an OFF observation position The Yes checkbox is automatically checked enter offset position for OFF observation e g 10 arcmin 0 arcmin which provides a 10 arc minute RA offset from the map target centre that will be used as the reference OFF position See Figure 6 34 for the final setup Click OK 97 Using HSpot to Create HIFI Observations Time Estimator settings Click the set the times button gt The Time Estimator Settings button pops up Select your estimate time in the corresponding scroll menu gt e g here Time Select the required time e g 1800 sec Choose the resolution of observations highest needed and goal resolution In the present case we take both as being 10MHz note that the goal resolution minimum can not be less than 1 1MHz for the WBS Clie
11. measures the efficiency of the telescope to measure point sources or its effective area compared to its geometric area The main beam efficiency Nm indicates the fraction of power coming in the main Gaussian beam of the telescope rather than sidelobes as compared to the total power The forward efficiency n measures the fraction of radiation received from the forward hemisphere of the beam to the total radiation received by the antenna Note that we have no obvious way to measure the forward efficiency since we cannot conduct skydips in the same fashion as ground based telescopes do OFF calibrations assuming a radiation temperature for the telescope can be used in flight see Section 5 2 66 HIFI Calibration For HIFI the forward efficiency has the value 0 96 In general the antenna temperature measured at a given frequency for a source needs to be corrected by either the aperture efficiency point sources or main beam efficiency extended sources divided by the forward beam efficiency in order to provide final calibrated source flux values Beam profile and efficiency measurements have been made using Mars raster map measurements These show values that are similar to the theoretical values for the beam efficiency The analysis of this data has been done and is included in Table 5 5 Beam efficiency values are used in the noise estimates from HSpot but are currently applied in the standard pipeline processing of
12. select CS then 39 38 in the two pulldown menus The final setup should appear as in Figure 6 22 Click OK This closes the Frequency Editor window On the Frequencies window click Done This closes the window and returns you to the pointed AOR setup window Observing mode setting Click the set the point mode button from within the AOR setup window We want to use the frequency switch mode Therefore select the Frequency Switch tab Select throw Small and large positive or negative frequency throws are available These vary across the bands and are chosen for best performance with standing waves in a given band Small throws are 86 Using HSpot to Create HIFI Observations around 80 100 MHz and large throws twice this For these observations we may want to select an OFF observation in order to calibrate standing waves on the baseline tick Yes in the reference box gt enter position for OFF observation e g an offset of 3 arcmin in RA or an OFF target position RA Dec See Figure 6 23 Click OK This closes the window and the user is returned to the AOT screen Time Estimator settings Here we indicate how much time we want to spend on the observation and or what noise level we want to reach Click the set the times button gt The Time Estimator Settings button pops up Select your goal setting as a time or a noise level in the top pulldown menu
13. the more strongly the problem is constrained It is important to point out that with each new LO setting there is a new bit of sky frequency that is covered and joins in the system of coupled linear equations that is the sum of the upper and lower side bands added pair wise It is always the case that the highest frequencies covered by the upper sideband of the highest LO setting and the lowest frequencies covered by the lower sideband of the lowest LO setting will only be observed once and only once combined in a sum Since there are unknowns at the extreme frequencies of the system a unique solution cannot absolutely be reached and a small insignificant periodic ripple may be seen in solutions that otherwise satisfy the system of equations well Comito and Schilke 17 have implemented minimization methods including the Maximum Entropy Method MEM and the Levenberg Marquardt Method to solve the problem including the case of crowded double sideband surveys of Orion observed with the CSO These authors found that in the case of well constrained DSB data i e data with high S N and many LO settings such that each frequency was combined with many others an iterative X minimization was sufficient to solve the problem and yield reliable single sideband results The MEM approach has been found to be useful with less redundantly sampled data sets In this approach a maximum entropy term is maximized such that the resulting solution has the l
14. 6 3 2 Example 2 A Dual Beam Switch DBS mode AGB Observation In this example we will set up two AORs to observe several water lines in the two sidebands of HIFI at two separate frequencies around 650 and 1717 GHz for an AGB star IRC 10216 There are some other useful bonus lines that we could also cover in these frequency ranges Since we are covering a large frequency range and do not require very high resolution we will use the Wide Band Spectrometer WBS only This will provide observations with a default resolution of 1 1MHz The spectral lines we might expect to obtain are provided in the list below Frequency setups considered JAS ROO A il O 1 O 1 xtine BSS 005 sla H20 9 7 3 8 8 0 para 645 834 GHz EAO Ole Si Si ol mont Nom Gm Oo A529 Olom Gre Bonus lines H O 1 1 0 1 0 1 6 3 4 5 4 1 H O 5 3 2 4 4 1 l co 6 5 E Ol SO2 22 22 B2 EO SSS ONOG aere C LLT OSI Ciz BAO S O SS2 2 eren Le 765 Cir Bonus lines H 0 3 0 3 2 1 2 Since our AGB star is known to be in relatively isolated with no potential contaminating sources likely to appear in our OFF beam positions we choose to use to Dual Beam Switch DBS mode 91 Using HSpot to Create HIFI Observations The following sequence indicates how we can set up such an observation i RUN HSDROE 2 Choose target Targets Menu gt New Target 2 1 Enter target name IRC 10216 2 2 Resolve the name using SIMBAD option and
15. 8000 frequency MHz ji L li Figure 5 17 CO 5 4 for NGC 7538 IRS 1 with WBS V spaced across the upper sideband from an engi neering Spectral Scan 69 HIFI Calibration 1342190187 WBS V lsb line range 557 000 0 025 GHz blue line is the average of 8 scans 3 0 eg ee ee ee a ee a ce ose 4 250F 4 ait 245 4 20m T Be E J z Bt ces a q gt J Z ERIS E 15E Jg E 4 M E J 2356 4 Lor q a E J E J 2305 4 ose 416 F J E J 2 25 E 4 oof E 2 20 E q ags revere ier rr er rrr ror erro a or oo rr re or oO Oc a 556 80 556 85 556 90 556 95 557 00 557 05 557 10 557 15 557 20 5625 5630 5635 5640 5645 5650 5655 Isbfrequency GHz LO Frequency GHz 1342190187 WBS H Isb line range 557 000 0 025 GHz blue line is the average of 8 scans 3 0 eg 2 55 a oo 250 25 2 45 2 0 15 max_intensity U N N W 8 v 3 2 N w a uo TOTP TTT TTT TT TT TTT a 22 TOT TTT TT tt n u 1s rel ea Ora ye tis Lev cr poitisritiritiritiiitiitis tii tis it it li li il it it p it 4 lii a W 1 ll 0 5 2 10 556 80 556 85 556 90 556 95 557 00 557 05 557 10 557 15 557 20 562 5 563 0 563 5 564 0 564 5 565 0 565 5 Isbfrequency GHz LO Frequency GHz Figure 5 18 Measurements of the 557 GHz water line at 8 positions in the LSB in WBS V upper and WBS H lower While the comparison between flight data and ground based gas cell measurements is ongoing the foll
16. Example 3 Scan Mapping of the Spectral Lines CO 7 6 and CI 2 1 in the Centre of M51 In this example we will set up an AOR that will allow simultaneous mapping of the two spectral lines of CO and atomic carbon CO 7 6 and CI 2 1 We will use HIFT s scan mapping mode referred to as On the Fly OTF mapping We will use a position reference The frequencies of the lines for our setup are given below Frequency setups considered A CO 806 652 GHz CI 809 343 Note bonus lines could be sought here The following procedure creates our M51 mapping AOR T R n HSpot 2 Choose target Targets Menu gt New Target 2 1 Enter target name M51 2 2 Resolve the name using SIMBAD option and fixed target tab Alternately input coordinates of the target by hand 2 3 Once resolved acknowledge source coordinate by clicking OK 96 Using HSpot to Create HIFI Observations 3 Setup observations Observation Menu gt HIFI single point 3 1 Setup A Instrument setting see Figure 6 32 mixer band scroll down menu choose 3a Radial velocity scroll down menu choose e g optical km s Redshift enter systemic velocity of M51 gt 463 km s Frame choose in the present case LSR Spectrometers WBS only Frequency setting preliminary gt Prior to the frequency setting it could be useful to import the lines of interest for display in the frequency editor On the Lines scroll menu choose either of the
17. HIFI achieves very high resolution spectroscopy that enables velocity structures also to be measured In this sense it is also an excellent instrument for determining accurate gas dynamics of a particular region with resolutions of a fraction of a km s easily possible 3 2 Primary Instrument Characteristics To fulfil the scientific objectives noted in Section 3 1 the HIFI instrument has been designed with the following important characteristics 16 HIFI Scientific Capabilities and Performance e complete coverage of 480 1250 and 1410 1910 GHz 625 240 and 213 157 microns to allow multiples lines of important molecules such as H20 to be sampled and to allow broad unbiased spectral surveys e a resolving power of up to 10 corresponding to a velocity resolution up to 0 03 km s requiring a narrow local oscillator line width and an Intermediate Frequency IF spectrometer measuring the frequency difference between signal and local oscillator signals with a resolution of up to 125 kHz e areceiver sensitivity of 3 4 times the quantum limit to make maximum use of the limited satellite lifetime requiring low noise mixers and IF amplifiers e a large instantaneous band width 4 GHz in each sideband to increase spectral survey speeds to minimize the risk of spectral coverage gaps and to observe broad features requiring mixers am plifiers and a spectrometer with 4 GHz of IF bandwidth e dual polarization operat
18. IF processing and data acquisition To cover the 2 x 4 8 GHz 2 x 2 4 4 8GHz for bands 6 and 7 input signals from the FPU two complete spectrometers horizontal vertical polarization are used For redundancy reasons both spectrometers are fully independent Each spectrometer receives a pre amplified and filtered IF signal 4 8 GHz After further amplifica tion in the WBS electronics the signal is split into four channels which provide the input frequency bands for the WBS optics 4 x 1 55 2 65 GHz IF1 to IF4 The signal is further amplified and equalised using variable attenuators to compensate for non uniform gain of the system before being sent to two Bragg cells in the optics module of the WBS The other necessary input is to provide a frequency reference signal for the frequency calibration of WBS spectra This is done using a 10 MHz reference signal from the Local Oscillator Source Unit LSU is fed into the WBS to provide a comb signal The comb signal in the WBS with regular stable 100 MHz line spacing can be connected for frequency calibration purposes or it can be disabled to provide a zero level measurement of the AOSs The zero allows allows more precise system temperature measurements to be made In the optics section of the WBS the pre processed IF signal from the mixers is analysed using the acousto optic technique The IF signal is fed into a Bragg cell via a transducer The IF signal then generates an acoustic wave pa
19. K ln M Marseille SRON Z Nagy Kapteyn Y Okada U K ln S Pacheco Obs Grenoble D Rabois U Toulouse Frank Schl der U K ln S Wang U Michigan M van der Wiel Kapteyn SRON M Yabaki U K ln U Yildiz U Leiden HIFI KP PI Representatives to the ICC AOT Team E Caux U Toulouse E van Dishoek U Leiden M Gerin Obs Grenoble 1 3 Acknowledgements The HIFI instrument is the result of many years of work by a large group of dedicated people It is their efforts that have made it possible to create such a powerful heterodyne instrument for use in the Herschel Space Observatory We would first like to acknowledge their work The manual itself included help and inputs from a number of people Particular help and contributions to this manual have come from e Anthony Marston ESAC editor 31 March 2011 e David Teyssier ESAC e Patrick Morris NHSC e Michael Olberg Onsala e Volker Ossenkopf U K ln Chapter 2 HIFI Instrument Description 2 1 Instrument and Concept 2 1 1 What is HIFI 2 1 2 HIFI is the Heterodyne Instrument for the Far Infrared It is designed to provide spectroscopy at high to very high resolution over a frequency range of approximately 480 1250 and 1410 1910 GHz 625 240 and 213 157 microns This frequency range is covered by 7 mixer bands with dual horizontal and vertical polarizations which can be used one pair at a time see Table 3 1 for detailed spe
20. Literature velocities have been compared with a set of HIFI line measurements and in all cases found good agreement given the uncertainties e g different species data S N ratios When possible a cross comparison between modes and a check of the spectral line repeatability has been made e g using the CO 5 4 line towards o Ceti also observed from ground by APEX Agreement between H and V and both spectrometers HRS and WBS has been verified in terms of line centre frequency and FWHM Agreement in nominal except for the centring of the line within the HRS frequency bandwidth because of a difference in computing and adjusting the sub band placement for the spacecraft velocity in different reference frames LSR vs SSB A solution to this problem is under investigation meanwhile the effects are significant only for the HRS when used in high resolution mode in the high frequency bands 54 HIFI Calibration 5 4 5 2 Multi epoch Frequency Consistency Observations of the same line and source at multiple epochs have also been compared and the detected line frequencies match The longest check was for source LDN1157 B1 taken 186 days apart and the motion of the spacecraft is correctly removed to an accuracy of better than 0 5 MHz 0 3km s This is illustrated in Figure 5 1 1342190183 WBS H lev 20 LO 570 942 ott wry who Lh bb amp bd bo a ircbed wededrde ik a and 10 flux K
21. OK Observation Estimates Click on the Observation Estimates button gt the HIFI Observation Breakdown pops up with the results Use the Show sequence parameters or Show message button to display more information gt here in particular we see the following message The map contains 13 lines This cannot be split efficiently into equal scans of multiple lines The total time yields 2268 sec including overheads This means that we may be able to ask for a slightly larger map and end up with a smaller time If you agree with the results click on OK Add Comments 4f you want to add comments to your AOR click on the Add Comments button and fill in additional comments Walehaloni taney you can check when the AOR is visible to the observatory by clicking on the Visibility button gt visibility windows are shown in separate window gt Opce all chis aie done Click OK on the HIFI Mapping window your AOR is ready and labeled Instrument Settings Mixer settings Redshift selection Mixer band ja Radial Velocity optical temis Save instrument settings Low limit GHz sori Optical redshift a300 c High limit GHa E515 Frame LSR lt Spectrometer choice Select the spectrometer to use wes ony zl WBS Resolution MHz 1 10 Separate setup for each polarisation of HRS sub bands EA The HRS Mode for H or both polarisations Nominal Resolution HRS Resolution MHz for H or both
22. Observing Mode Having setup the spectrometers and frequencies we wish to use the observing modes can be chosen The observing modes are described in Chapter 4 Here we show how to select and setup the modes in HSpot Point Source Modes The HIFI Pointed observations AOT has at bottom centre a button for selection of the available pointed observing modes Clicking this button presents the user with the window shown in Figure 6 10 In order to select the mode you wish to use you need only click on the appropriate tab The modes available are e Dual Beam Switch DBS options are the use of a fast chop e g with bright sources and continuum timing when the level of the continuum needs to be accurately made e Position Switch this requires an OFF reference position which can be identified as an offset position or an absolute position see Figure 6 11 ONLY THE FORMER IS AVAILABLE FOR MOVING TARGETS e Frequency Switch this requires a frequency throw input from the user An OFF reference is highly recommended for use with this mode ONLY OFFSET POSITIONS ARE AVAILABLE FOR MOVING TARGET REFERENCE POSITIONS e Load Chop an optional OFF reference position can be input na Observing Mode Observing Mode Settings Choose one of the modes below Dual Beam Switch i Load Chop Frequency Switch No mode selected Position Switch You must select an Observing Mode Cancel Figure 6 10 HIFI pointed mode s
23. Standing Wave Residuals after Calibra tion Pipeline Level 2 4 3 1 The HIFI pipelines are designed to correct for standing waves in the astronomical data using off source sky spectra taken in AORs using any of the observing modes that include OFF source sky measure ments i e telescope nodding plus chopping with the internal M3 mirror using fixed throws on the sky the DBS modes or else telescope nodding to a User selected reference sky position modes using a position switch Here we present a summary of residual standing waves in that remain following standard pipeline processing up to Level 2 products provided in the Herschel Science Archive HSA The information is based on data taken with the Point AOTs that have all been reference corrected in the standard fashion Frequency Switch and Load Chop observations have all included the sky refer ence option in HSpot recommended Approximations can be made in IA for skipping this option to a corresponding No Ref version as allowed in HSpot by simply skipping the sky correction step in the pipeline Attempts to remove these waves in HIPE are also discussed Because the wave characteristics differ between bands with beam splitters and diplexers as well as between SIS and HEB mixers they are discussed separately The conclusions are based on the limited dataset available from the HIFI perfor mance verification phase Bands 1 5 SIS mixers Bands 1 5 data taken in DBS mode general
24. T T Ta A z E 4 i 3 4 2 A 4 ool gt ae J l ae F we re etd C E E a ed E a 5 5300 5310 5320 5330 5340 5350 5360 5370 frequency MHz Figure 5 10 Obsid 1342190184 Emission in chop position affecting On source profile The contaminating emission affects the line profile until just beyond the peak and so has no influence on the discrepant H and V profiles seen in the extended wing From the above an investigation of the separate emission in the reference positions and ON source is warranted To do so the observations were reprocessed skipping the doRefSubtract and doOffSubtract steps of the Level 1 pipeline The reference and source measurements could then be investigated in the ON and OFF positions Figure 5 11 and Figure 5 12 show the H and V profiles derived from the ON and OFF positions separately for the obsids 184 and 229 respectively A profile difference can be seen even in one polarisation between the two positions 134219014 Aa i a GS da Fl ms Fa is LN et a Us a ak i ft A as eee LN E f EE rence Pye Pega Topar po one oree Pye ty Segoe yl ye ay epee i yoan Pp ais elf pan Boy 5330 5332 5334 5336 5338 5340 5342 5344 5346 5348 5350 5352 5354 5356 frequency MHz ES RERED REREN EEREE ERRES N i Hls Hfrmmof HfromOn VifromOff V from On Figure 5 11 H and V profiles derived from ON and OFF positions separately f
25. WBS Sys Freq Resn km s HRS nominal res Sys Freq Resn MHz HRS nominal res Sys Freq Resn km s HRS high res Sys Freq Resn MHz HRS high res Sys Freq Resn km s 1 09 1 09 1 10 1 11 1 12 1 14 1 19 0 68 0 51 0 41 0 35 0 30 0 27 0 22 0 28 0 30 0 32 0 35 0 38 0 42 0 55 0 18 0 21 0 24 0 27 0 31 0 37 0 50 0 11 0 10 0 10 0 09 0 08 0 08 0 08 Frequency and Velocity Verifications Summarizing no serious problems have been found with the frequency and velocity calibration in the HIFI pipeline processing of in flight data There are some issues which the User should be aware of when interpreting the frequency scales on pipeline processed Level 2 spectra Until these issues are understood and fixed they will cause an error in the frequency scale of up to 2 km s Some residual outstanding issues are e The Sun is used instead of the Solar System barycenter SSBC leading to lt 0 020 km s error in the value of the Local Standard of Rest LSR used e In order to compute the spacecraft velocity HCSS uses an imprecise velocity of the earth with respect to the sun and not the SSBC This gives an error of lt 1 5 km s e At present the HIFI pipeline produces Level 2 spectra with frequency axis in the LSR frame in cluding Solar System Objects SSOs SSO spectra should be presented in their rest frame Frequency Consistency With Ground based Measure
26. a single IF band Uses chopper to view fixed sky positions for reference 3 either side of the target position Description In this mode an internal mirror is used to provide the motion to a reference OFF position on the sky The reference OFF position is currently set to be 3 arc minutes from the ON target position and is not adjustable by the user Moving the internal mirror changes the light path for the incoming waves subjecting the measurements to the possibility of residual standing waves so moving the telescope in such a way that the source appears in both chop positions is expected to completely eliminate the impact of standing wave differences in the two light paths The low dead time in moving a small distance with the telescope and in the internal chopper motion makes this mode more efficient than position switching Mode I 1 A diagram showing the telescope and chopper positions is shown in Figure 4 3 30 Observing with HIFI K A j wr telescope al slew 7 Figure 4 3 HIFI Dual Beam Switch positions on the sky Two chopper speeds are available to the user a slow chop mode with typically 0 125Hz chopper speed Mode I 2 and a fast chop DBS Mode I 2a with a frequencyup to 4Hz The faster chop is intended to compensate for instrumental drifts at low frequency resolutions that would otherwise at the slow chop rate lead to baseline distortion and increased intensity uncertainties If accurate cont
27. and Berg T THz HEB heterodyne receivers for space and ground based radio astronomy 2005 Proc Europ Microwave Assoc vol 1 no 3 8 Schieder R Siebertz O Gal C Olbrich M Schloeder F Bieber R Schmuelling F Tolls V and Horn J Toward Very Large Bandwidth with Acousto Optical Spectrometers 2002 SPIE 4855 313 324 9 Belgacem M Ravera L Caux E Cais P and Cros A The high resolution versatile digital spectrometer of HIFI HSO 2003 New Astronomy 9 43 10 Ossenkopf V The intensity calibration framework for HIFI 2003 ALMA Memo 442 11 Kramer C Spatial Response Contribution to the framework document of the HIFI Herschel calibration group HIFI ICC 2003 30 version 1 8 May 2006 12 HIFI ICC Frequency Calibration framework document L3AB HIFI CAL 2003 02 13 HIFI ICC HIFI Calibration Plan LRM ENS HIFI PL 2000 001 14 Penzias A A Burrus C A 1973 ARA amp A 11 51 15 Schlegel D J et al 1998 ApJ 500 525 16 Kutner M L Ulich B L 1981 ApJ 250 341 17 Comito C Schilke P S 2002 A amp A 395 357 18 Ossenkopf V 2008 A amp A 495 677 109 Appendix A Change Log Version 2 3 31 March 2011 GT2 call opening update e Chapter 5 Updated information on spurs and representation in HSpot v5 3 e Chapter 6 Complete update of screenshots and examples using HSpot v5 3 Version 2 2 20 January 2011 GT2 call
28. be an area of the sky that is known or else assumed to be free of emission at the requested frequency The reference position must be sampled sufficiently frequently so that detector drifts are adequately compensated The switching rate is calculated automatically in the AOT logic based on knowledge of the instrument stability time and internal calibrations e g frequency calibration may be performed during initial slews to the target or during telescope movement during the observation Schematically a timeline for this mode may be represented as follows Figure 4 2 Telescope OFF position COO no AR i i j j 4 i i i yi H X i aze el lf source position HHH MPT i al E Tuning of the instrument f ll Zero and comb integration i I Integration on hot load I Integration on cold load initial position I Integration on sky Figure 4 2 Timeline of HIFI position switch AOT General Usage Ideal for sources in crowded fields or regions of extended emission for which accurate flux measure ments are required An OFF position which is free of emission at the selected LO frequency must be within 2 degrees of the ON target position Advantages Accurate intensity calibration of the observed spectral line can be achieved if an area of the beam within 2 degrees of the science target is emission free and timing constraints on the integrations at the ON an OFF positions based on knowledge of the system stability ar
29. data for the most spatially and spectrally complex targets in single pointing modes and therefore no further alternatives are offered User inputs Target ON position optional reference OFF position LO band and frequency minimum and max imum goal frequency resolution of the calibrated data spectrometer usage and total observing time or noise limit at the lowest goal resolution Data calibration 4 2 2 The observing mode of load chop observations with an OFF calibration is extremely robust with re spect to calibration uncertainties because it uses a double difference to determine the flux from the astronomical source relative to the flux from the sky on the OFF position The double difference com pletely cancels out all uncertainties in standing wave contributions from the receiver noise and from warm telescope components promising a perfect calibration of the underlying continuum or a perfect zero level baseline in case of sources with no continuum contribution The mode also guarantees a cancellation of all intensity drift effects that are purely linear within the corresponding cycle time This robustness is however obtained at the cost of an increased spectral noise produced by the dou ble difference If the period of standing waves in the system is equal to or less than the desired fre quency resolution of the observations the observing time has to be doubled to obtain the same sig nal to noise ratio as compared to obs
30. ee ch nd ES el 110 Chapter 1 The HIFI Instrument Observer s Manual 1 1 Purpose of this Document The HIFI Heterodyne Instrument for the Far Infrared observer s manual is intended to assist in using the HIFI instrument on board ESA s Herschel Space Observatory Documents on the detailed docu ments on design and operations are available from the Herschel Science Centre HSC and the HIFI Instrument Control Centre at SRON Groningen The Netherlands HIFI ICC who are responsible for the safety and calibration of HIFI during operations Help and information on HIFI can be obtained by contacting the Herschel Science Centre at the fol lowing web address http herschel esac esa int Follow the link on the page to the Helpdesk for problem enquiries This document contains overview information on instrument concept and design its scientific perfor mance and calibration It also contains all user relevant information on observing modes and Astro nomical Observing Templates AOTs Examples of AOTs for HIFI are presented with their usage HIFI data from the Herschel Space Observatory are automatically processed at the HSC after the data is received from the spacecraft The standard processing pipeline is described here together with a description of the data products Both the raw and pipeline processed data are made available to the user Finally a brief mention is made of software tools that have been more specifically prov
31. following JPL or CDMS lines to query and import lines from those catalogues Manage Lines in order to import personal lines into the line list There are two options here Import a user defined formatted line file clicking on the Import button Ad Specific lines clicking on the Add button Frequency Setting gt Once all desired lines have been imported in the line dkat ene g Click on the Set the observing Frequencies button gt the Frequencies window pops up GCilaok On the Ads wc Ue ny gt the Frequency Editor window pops up On the Frequency Selection table gt we will put the CO and CI lines in the LSB thus LOF of order 813 GHz select CO line in the line scroll down menu Tick the Upper Sideband box select the corresponding transition of interest in LSB in the present case the CO J 7 6 line gt the slider automatically moves to locate the chosen line in the first half of the WBS band lowest noise LOF becomes 811 21 GHz Check all the desired lines targeted plus bonus lines are within both side bands If not move the frequency sliders in order to do so Avoid locating lines in the middle of the WBS sub band gt in the present case we need to slide the LOF in order to locate the CI line in the LSB as well We end up with e g LOF 812 70 GHz Note however that this could be just too short considering the total line width of order 0 8 GHz 300 km s and thus the need for sufficient
32. for Nyquist sampling of the beam size for the chosen frequency and 10 20 or 40 arcseconds The mode works for each grid position in the same way as for the point source dual beam switch mode see Mode I 2 The beam switch samples sky at 3 arc minutes either side of each grid position with a telescope movement occurring between changes to the beam switch either side of the grid position Advantages Can improve the accuracy of flux measurements for point sources for any cases where the pointing error or known position is large compared to the beam size 39 Observing with HIFI Provides basic flux and spatial information on small extended sources Disadvantages and Alternatives Can not be used for large maps and not a good means for obtaining accurate total flux information for extended sources For accurate pointing and for objects with well known positions some time is lost since the telescope beam is slightly offset from the target position for each of the cross positions User inputs Continuum timing for accurate baseline measurements and fast chopping are also selectable Data calibration Each cross map position can be calibrated in the same way as single point dual beamswitch data see Section 4 2 1 2 4 2 2 4 Mode Il 3 OTF Maps with Frequency Switch Description In this mode a scan map is made across a source during which frequency switching is introduced The mode works for each scan map positi
33. full frequency resolution of HIFI is not necessary to sufficiently sample the standing waves to be corrected in the system Considering the typical optical paths involved in the instrument it is sufficient to measure the standing wave effect with a frequency resolution of 10 MHz Since we are smoothing our OFF measurements to a lower resolution some reduction in the observing time is required for characterisation of the standing waves with sufficient signal to noise For an accurate treatment of the standing wave effect additional assumptions must be made on how they contribute to the instrument response standing wave model Two other parameters add to the un knowns when considering OFF measurements the telescope forward efficiency 1 and the telescope radiation Jr eg All these effects are superposed in the OFF measurements It is however reasonable to assume that standing waves will appear as the variation across a band while the telescope contribution will be identified as an average contribution over the band see 10 So far we have considered three standing wave cases e standing wave contributing as additive terms to the receiver noise across the bandpass e g sine waves e standing wave changing the coupling to the telescope via the forward efficiency e standing waves changing the overall gain Such waves show up as enhanced spectral baseline ripples against strong continuum sources such as planets The preference to one or
34. nature the HRS frequency calibration is in principle entirely reliant on the master LO The frequency conversion table is thus completely defined by the parameters and equation compiled in 12 5 4 4 Frequency resolution WBS frequency resolution In the WBS the channel size is in principle defined by the pixel size on the CCD matrix sampling the data However the frequency width sampled by this pixel is not neces sarily regularly spaced as the diffraction angle created by the acoustic wave is not a linear function of the Bragg cell length For HIFI the total bandwidth is 4 GHz made of 7650 valid pixels The spectral resolution of each pixel is obtained via a COMB measurement which also used to derive the frequency calibration The number of channels between two peaks of the COMB of known frequency separa tion translates into the width of the resolution element 53 HIFI Calibration 5 4 5 5 4 5 1 ments HRS frequency resolution The HRS frequency resolution can be seen as a digital entity In principle it is solely dependent on the sampling clock speed on the lag window used i e the apodisation generally Hanning windowing and on the quantisation level The overall HIFI frequency resolution budget is summarised in Table 5 3 Table 5 3 HIFI resolutions using the WBS and HRS in two of its modes Band 1 2 3 4 5 6 7 LO Freq Resn MHz 0 122 0 163 0 204 0 244 0 285 0 330 0 486 WBS Sys Freq Resn MHz
35. opening e Chapter 3 Tsys plot updates for bands 4 correction and 5 e Chapter 5 spur list updated in section 5 4 6 4 e Chapter 5 additional spectral purity information in section 5 4 6 from original release note Version 2 1 15 December 2010 AO1 start of observations e Beam profile updates in Table 5 4 e Beam efficiency measurements based on in flight experience in Table 5 5 e Chapter 5 description of application of efficiencies in HIFI standard pipelines e Chapter 5 updated section on spurs in band la now removed in current HIFI operations e Chapter 5 error budget table s updated Version 2 0 20 May 2010 AO1 e Substantial changes mostly based on in flight experience e Chapter 1 included some latest results e Chapters 3 to 5 completely updated based on changes to observing modes and calibration infor mation obtained in flight e Chapter 6 changed figures to match changes in HSpot front end Examples remained substantially unaltered Version 1 1 14 May 2007 e Updated sensitivity figure 3 3 in section 3 4 1 Updated section 4 2 2 3 on cross map to include the mode changes recently incorporated avail ability of selectable cross step size Changed figure 6 2 to new HSpot front end Updated section 6 2 1 1 to indicate new save and load facilities from instrument and frequency settings for HIFI Updated section 6 2 2 3 to include information on storage of time estimates in A
36. other of these models is currently being investigated for different LO settings and cases from the performance verification phase 51 HIFI Calibration 5 3 3 Differencing observations To correct for instrument drift effects the astronomical observations will use a differencing scheme where the astronomical source and a reference are observed in an alternating sequence HIFI uses four basic approaches total power also called Position Switch sky chop also called Double Beam Switch load chop and frequency switch see chapter on observing modes Reference 10 gives some examples of the equations obtained in various differencing schemes and depending on the standing wave model approach In particular it shows how both line and continuum contributions to the signal can be separately treated The continuum term only contains the radiation from the source and the blank sky in its surrounding The continuum radiation seen from the warm telescope structure cancels out in all equations by means of the OFF calibration In essence the OFF calibration combined to the differencing approach always provides a double dif ference The double difference corrects for the standing waves in the baselines but from the point of view of observational noise ON and OFF measurements are equivalent Thus the use of an OFF calibration may be less efficient that total power measurements This is depending on the system sta bility which could offer the pos
37. per formed during slews to the OFF position The efficiency of the mode profits from high scan velocities the map will be typically observed in a series of multiple coverages adding up to the required total integration time per source position The time line of the observation consists of motions of the telescope across the map and between the map and the OFF position integrations of the instrumental output during the different phases and interleaving load calibration measurements Figure 4 7 shows the timeline for the OTF mapping mode lt AN AWN DANNS Source map RQ W e Data readout Direction of telescope motion OFF position Figure 4 7 Timeline of the path on the sky for a HIFI OTF mapping mode The green dots indicate regular data readouts of the spectrometers The OFF position is returned to at the end of an integer number of scan legs This is typically 1 or 2 except in the case of small OTF maps 37 Observing with HIFI In the example shown in Figure 4 7 the OFF position is visited three times within one coverage of the whole map after every two scanned lines It is planned to always complete full scan lines before an OFF observation A series of subsequent coverages will be performed with one extra OFF mea surement at the end of the observation guaranteeing a complete enclosing of the source observations by OFF observations The green dots symbolise the points where the spectrometers are read out The in
38. see Figure 6 15 B Time Estimator Settings x Time Estimator Settings Estimate Type Time z Resolution units MHz r J One GHz Reference Res Min Width Res Max Width Noise Goal i Cancel Figure 6 15 The time estimator settings window with appropriate user values placed in the table cells An initial time seed estimate of 1200 seconds a maximum resolution width of 10MHz and the highest resolution minimum resolution width that the data is to be used at is given as 1 1MHz The resolution at which the data is expected to be used and the highest resolution needed for the data can be input by clicking on the appropriate table cell and inputting a value If there is a time goal the time the user expects to take for the observation is placed in the time cell of the time estimator table A similar situation exists for setting a noise goal in Kelvin For users with narrower lines in particular the 1 GHz reference should be checked This is good for most observations in fact but for broader lines this should be made to be unchecked Referencing is then done in such a way as to improve the overall stability across the band but additional time is taken to reach a given noise goal Once the appropriate values have been input clicking OK stores the user values and will use these in time noise estimates 6 2 2 3 Getting a Time and Noise Estimate In order to get an accurate time estimate and associated noise
39. set the times button gt The Time Estimator Settings button pops up Select your estimate time in the corresponding scroll menu gt e g here Noise Select the goal noise for the observation e g 50 mK and place in the noise column for the time estimator Since we are using the WBS only the goal resolution minimum must be 1 1 MHz or more Change the minimum resolution to 1 1MHz Cilio OK Observation Estimates Click on the Observation Estimates button gt the HIFI Observation Breakdown pops up with the results Use the Show sequence parameters or Show message button to display more information If you are happy with the results click on OK Add Comments if you want you may add comments to the AOR click on the Add Comments button and fill in additional comments Vas iba 1eby you can also obtain the dates when the AOR is visible and can be scheduled by the observatory Click on the Visibility button gt visibility windows are shown in another window gt Once all this as done click OF on the Hist single point Observation window your AOR is ready and labeled Instrument Settings Mixer settings Redshift selection Mixer band aa x Radial Velocity optical km ish z Save Instrument settings Low limit GHZ E Optical redshift 26 00 Load instrument settings High limit GHZ EE Frame LSR v Spectrometer choice Select the spectrometer to use wes only z WBS Re
40. sky 4 Visualise planned observations 4 1 Select the AORs of interest in the main Observations window use On checkbox 4 2 On the Image scroll menu select the image of interest e g DSS POSS1 red gt a plate of IRC10216 appears 4 3 On the Overlays scroll menu select AORs on current image 4 4 Click on Checked AORs I the target visibility table pops up 4 5 Choose a date then click OK In the present case e g 2011 Apr 21 000000 gt the DBS point positions appear overlaid on the DSS plate as circles with diameters of the same width as the beam Blue indicates target beam positions with green circles indicating the chopped beam positions see Figure 6 31 walxl mo gt ae HPoint 0002 F XJE1 816 7 Target mxl a F x2 Figure 6 31 Image overlay of the two dual beam switch AOR examples on a DSS image of the region The two chopped positions are shown in blue and green for the two phases of DBS mode The target is marked by a red square 6 4 Example Setup of a HIFI Mapping AOR HIFI has four modes for mapping three that are variants of On The Fly mapping and a DBS raster mode which uses dual beam switch measurements at each of the points on a raster Scan maps can use a position reference OFF position or reference frequency frequency switch or the internal loads as reference load chop in its calibration The reference for the raster case is provided by the beam switching 6 4 1
41. spatial clustering of targets into a single observation is NOT available for HIFI observations A limited grouping of observations in a single band with a given setup but a limited number of fre quencies is currently planned to be available at a later date 4 6 Solar System Target Modes All modes available for fixed targets noted above are available for moving targets also One restric tion on solar system targets is that fixed positions used as references can NOT be used All OFF ref erence positions must be expressed as being relative to the target 48 Chapter 5 HIFI Calibration 5 1 Introduction This chapter gives a general view of the calibration concepts chosen for the HIFI instrument This chapter is intended to provide an overview of how HIFI is calibrated the full details of which are contained elsewhere but are referenced in this chapter Further calibration information of use to users will also continue to be placed in a calibration page available via the Herschel Science Center wesbite at http herschel esac esa int The HIFI calibration approach can be broken down into three main areas e intensity calibration e frequency calibration e spatial response calibration It is the combination of each of these three steps that provides the most accurately calibrated HIFI spectrum see summary in section Section 5 5 For each of these areas a framework document has been produced describing in extensive details
42. spur this one is very weak and sometimes disappears altogether likely due to changes in instrument temperature It is illustrated in Figure 5 4 It is still recommended to place this spur in a subband different from that of the water line The position of the spur in the IF as a function of LO is fit well by the following formula IF 5064 9 44 3x 0 6x where x LO 1090 498 GHz 5 0 a TT iE a ia Sa a a i a ae ee i T T me ae a a oo Ek i 7 ET E 45E A do E BS B SSE 4 E 3 o 3 0 E 2 5 E oe E 3 206 E r E ESE f LOE 0 5 E 4 E 0 0 E 4 B ll 1 a oo oe A l i I I on ob i l I I L iLE jj I I l i I 13 4000 4500 5000 5500 6000 6500 7000 7500 8000 frequency MHz Figure 5 4 Though band 4b spurs are strong compared to real lines they are very narrow and do not seem to affect the integrity of the spectra around them This spectra was taken during PV at an LO setting of 1105 6 GHz 5 4 6 4 Spurs Across Other Bands Further analysis of spurs is ongoing based on observations taken during performance verification A summary of the table that HSpot uses to identify problem settings and warn users is provided here Users who need LO tunings in any of the affected ranges are encouraged to contact the helpdesk s for advice Note that the ranges could be as much as 2GHz wider on each side of a spur due to the resolution of the surveys from which these were determined
43. target 19 Star tracker target Ra 68 095 degrees Dec 24 476 degrees Mode Settings Settings Mixer band la Range Full Band vy Range From GHz 488 1 Range To GHz 551 9 Redundancy 6 v WBS Selection Both v Only the WBS is used in this mode Observing Mode Settings Time Estimator Settings Observing mode settings Time estimator settings Set the observing modes Set the times Observation Est Add Comments Visibility Figure 6 36 Filled in AOT for the example spectral scan observation In order to complete our survey we will also need to do a full spectral scan of the whole of band 1b The following shows how this can be done 3 2 Setup B Mode setting mixer band scroll down menu choose band 1b Full B ra Redundancy 6 as above for consistency Botn WDS Chicca No fast chop no continuum Time Estimator settings Select your estimate time in the corresponding scroll menu gt e g here Time Select the required time in the table below e g 3000 sec Observation Estimates same as setup A Add Comments same as setup A Wal Siallont dlane same as setup A gt Once all this is done click OK on the HIFI Spectral Scan window your AOR is ready and labeled 102 Chapter 7 Pipeline and Data Products Description 7 1 Data to be Passed on to the User All Herschel instrument data processing pipelines are designe
44. the request then the returned value observation time estimate is the minimum for the input spectral scan settings Observation Estimates Ciick on the Observation Estimates button gt the HIFI Observation Breakdown pops up with the results gt we end up here with approximately 7607 seconds for a time estimate and a noise of 10 mK Use the Show sequence parameters or Show message button to display more information If these results are alright then click on OK If not then change the instrument settings and or the time estimator settings appropriately Add Comments the user may add comments to the AOR e g This AOR forms part of CSUR Vy mO cn Ole Oem usGOMe4icG stom oc OMGH 7a se hOmCOmits hts au Glan keno the Add Comments button and fill in additional comments text Visibility if you are interested in knowing when the AOR created is visible to the observatory click on the Visibility button gt visibility windows are shown in another window Once ULL this ie done Cillier OF on theo Sele single point Observation window your AOR is ready and labeled and should appear in the Observations window of HSpot 101 Using HSpot to Create HIFI Observations KJ HIF Spectral Scan Unique AOR Label HScan 0000 Target IRAS 16293 2422 Type Fixed Single Position 16h32m22 80s 24d28m33 0s New Shows Target currently enabled for operation ft st Number of visible stars for the
45. wm ssolator ampitier trma amti y enpramuss Fupcorwerter nenese Petrometers f ma levd 118 Jamat DI dimme 20 dBmMH 90 damat min level 12 dirbk 100 oie 7O dimatke 100 d imete Fgan 148 3948 34B H 08 268 10B 348 24b V4 Okr 24 43 Of F Fan 148 23540 sa 2a sab 348 240 ma levd 118 danat 08 JEMMHE 25 dBmMH 90 dBm min level 1 dha 100 dimatke 95 dimatht 10 d imate 4 8GHrIF Figure 2 11 The HIFI signal chain In Bands 1 to 5 each Signal Chain consists of a mixer followed by two isolators and two amplifiers For each polarization the outputs of these 5 independent chains are combined so that only two cables are needed to carry the IF outputs from these 10 channels of the FPU to the service module The situation in Bands 6 and 7 is similar except that isolators are not used because they are not available for the 2 4 4 8 GHz IF band that is needed for the HEB mixers Thus the second pair of IF output cables from the FPU includes the combined outputs of the two polarizations of Band 6 and 7 The other difference in the Band 6 7 Signal Chain is that an IF Up converter is needed to transform the 2 4 4 8 GHz output of the FPU to 8 5 6 GHz for compatibility with the spectrometers HIFI Instrument Description Within the IF Up converter in the service module a 3 dB Coupler is also used to combine the Bands 1 5 and 6 7 outputs so that each polarization of the Wide Band and H
46. 0 8000 frequency MHz m Figure 3 12 Band 1b showing an IF mismatch at 7000 MHz It is particularly noticable in the V polarization at this LO frequency Bands using diplexers In the diplexer bands 3 4 6 and 7 a substantial increase in system temperatures and thus decrease in sensitivity occurs towards the edges of the IF bandpass For Bands 3 and 4 the IF bandpass span is 4 GHz 4 8 GHz and the last 500 MHz at either side between 4 0 4 5 GHz and between 7 5 8 0 GHz has a significant increase of baseline noise since the diplexer mechanism introduces extra losses in these locations Tsys can increase by up to 50 100 as compared to the central part of the IF The high frequency bands 6 and 7 These bands also have diplexers with the characteristic U shaped sensitivity across the IF range However the nixer gain dependence over the IF leads to a systematic rise in system temperatures reduction in sensitivity from the lower frequencies of the IF band to the higher frequencies An illustration of the sensitivity change for band 4a is shown in Figure 3 13 23 HIFI Scientific Capabilities and Performance 3 5 4 Tsys WBS H 4a 997 0 GHz 374 89K TARLI RELER ERRET GEE A A A T 4 fovoitiiiitiriitipii tiie titi tii LN RES RASSI LESES LASAS LAASI LALES BALAS LEGAS BE BET si a sw dal aa aE al al 4000 4500 5000 5500 6000 6500 7000 7500 8000 frequency MHz Tsys WBS H 6a 1478 0 GHz 15
47. 07 Cancel j Figure 6 29 Final setup of the frequency editor For the next frequency setting we will create a second AOR Select again HIFI Single point in the Observation scroll down menu 3 2 Setup B Instrument setting mixer band scroll down menu choose 7a Radial velocity scroll down menu choose e g optical km s Redshift enter velocity of IRC 10216 gt 26 km s Frame choose in the present case LSR Spectrometer WBS only Frequency setting preliminary Same as for setup A if you have not restarted HSpot in the mean time the line list you previously selected is still available for this second frequency setting 94 Using HSpot to Create HIFI Observations Frequency Setting gt Once all desired lines have been imported into the line Ireege Click on the Set the observing Frequencies button gt the Frequencies window pops up Click on the Add button gt the Frequency Editor window pops up On the Frequency Selection table gt we will put the H20 lines in the USB LOF around 1714GHz select H20 line an the line scroll down menu Tick the Upper Sideband box select the corresponding transition of interest in the USB in the present case the 5 3 3 6 0 6 gt the slider automatically moves to locate the chosen line slightly offset from the centre of the WBS band LOF becomes 1714 30 GHz Check all the desired l
48. 3 2 List of HRS configurations available in each polarization Number of Spectral reso Mode bands per po Number of Number of off lution kHz Channel spac larization x lags set channels Hanning type ing kHz bandwidth apodisation High resolution 1 x 230MHz 1 x 4080 16 125 64 Nominal reso 939MHz 2x 2040 16 250 125 lution Low resolution 4 x 230MHz 4x 1020 16 500 250 Wide resolu 4 x 460MHz fin band x2 4x 510 x2 16 1000 500 3 5 Mixer Performance 3 5 1 Further information beyond what is provided here can be found on the Herschel Science Center s web site for the AO release http herschel esac esa int AOTsReleaseStatus shtml Please see this area for more detailed information and any updates on HIFI instrument performance and AOTs The calibra tion pages will contain up to date calibration information including system temperature vs IF for all tuned LO frequencies also see Section 3 5 2 System Temperatures Figure 3 4 summarises the current status of measured mixer performance in each of the HIFI mixer bands The values shown are the ones currently used in HSpot used in planning HIFI observations These values are good for the currently measured best polarization for each band Some variation in sensitivity does occur across the IF frequency band see Section 3 5 3 and some deterioration of sensitivity occurs towards band edges notably for the situation where dip
49. 92 409K IAEA FEJ ECE Gop td EI 2400 2200 2000 Tsys K 1800 1600 1400 Mop opp tty ttt 7 eiler erit eia tii teri tii ilor ilia ela 1200 tee lrs Erlis Elyas Ee le 5500 6000 6500 7000 7500 8000 frequency MHz Figure 3 13 Variation of IF sensitivity at 997 0 GHz in band 4a and 1478 0 GHz in band 6a that shows the typical variation of system temperature across the IF band for a diplexer subband including in band 6a for an HEB mixer An additional drawback is degraded stability performance stronger standing waves and poorer base line performance Note that such stability issues can be mitigated by using Fast DBS but not the sensitivity degradation The option 1 GHz ref can be used i e un ticked to help with the stability of the degraded part of the IF at band edges It is thus a recommendation to avoid placing lines in the last 500 MHz on either end of the IF in Bands 3 and 4 and in the last 250 MHz in Bands 6 and 7 when using modes of the Point or Map AOTs In cases where two lines are being targeted in the edges of the upper and lower sideband in a single AOR it is better to devise separate AORs for each line despite the additional 180 sec slew tax since time is not being saved in a single AOR when the noise and standing waves are impeding spectrum quality Note that spectral lines selected in HSpot are automatically placed in the best part of the IF frequency band for sensiti
50. 92 and 98 MHz red relative to the baseline green 45 Observing with HIFI 4 3 2 Position Switch Frequency Switch and Load Chop modes Calibrated observations taken with the simple Position Switch Frequency Switch with OFF refer ence or Load Chop with OFF reference modes in beamsplitter Bands 1 2 and 5 also show clean spectra If any residual waves are present in the Level 2 products they have the shape of pure sine waves and can be subtracted using the FitHifiFringe task in HIPE Observations in diplexer Bands 3 and 4 often show residual waves with larger amplitudes compared to the DBS modes Waves generated in the diplexer rooftop are not pure sine waves Amplitudes increase strongly toward the IF band edges It is thus always advised to place the line of interest near the middle of the IF band when possible in WBS sub bands 2 or 3 Although FitHifiFringe only fits sine waves fits to the diplexer waves can be approximated using multiple sine waves typically around 600 MHz The approximation is not as good at the IF band edges Figure 4 10 and Figure 4 11 show examples for Band 3b and 4b Note that the baseline is strongly curved in both observations and the user will need to remove these separately in HIPE using polynomial fitting flux K flux K 879 360 B81 382 BB 879 880 881 882 883 Isbfrequency GHz Isbfrequency GHz Figure 4 10 Band 3b observation using Point Frequency Switch at Level 2 a
51. 94 94 288 2a 288 94 94 288 2b 288 94 94 288 3a 288 94 94 288 3b 288 94 94 288 4a 288 94 94 288 4b 288 94 94 288 5a 300 98 98 300 5b 300 98 98 300 6a 192 96 96 192 6b 192 96 96 192 Ta 192 96 96 192 7b 192 96 96 192 Data Calibration Frequency switched observations will be calibrated in two main steps e standard calibration resulting in a difference spectrum and e the coaddition of the contributions from both phases For the second step several common software tools will be available to the user but the result has to be interpreted with care by the user based on available knowledge of the expected source spectrum It is in general not possible to generate a normal spectrum representing only one frequency phase from the difference spectrum In the simplest approach shift and subtract the difference spectrum is shifted relative to itself by the frequency switch step and subtracted resulting in calibrated lines with the best possible signal to noise ratio but where each line is accompanied by ghost lines with the 34 Observing with HIFI opposite sign which cannot be easily removed None of the more sophisticated methods are expected to completely eliminate this problem This can also be achieved via the doFold task in HIPE For the basic calibration of the difference spectrum step 1 the difference of the measurement between the two phases on
52. AGS Renae Spectroscopy Se PG F Instrum Mode Information Durati Stat 01 SPIRE Photometer SPIRE Spectrometer SPIRE PACS Parallel Mode FH Observations Target None Specified Total Duration hrs Figure 6 1 HSpot Observation menu on the Observations screen Pulling down to HIFI Single Point or HIFI Mapping starts up an AOT setup window For pointed and mapping observations this initial window looks similar see Figure 6 2 gt HIFI Single Point Observation Unique AOR Label HPoint 0000 Target None Specified Shows Target currently enabled for operation Target st New Target J Number of visible stars for the target None Specified Instrument Settings Mixer settings Redshift selection Mixer band 1a _ Radial Velocity redshift Be Save instrument settings Low limit GHz 488 1 Redshift 0 000000 Load instrument settings High limit GHz 551 9 Frame LSR Spectrometer choice Select the spectrometer to use WBS amp HRS WBS Resolution MHz 110 Separate setup for each polarisation of HRS sub bands No The HRS Mode for H or bath polarisations Nominal Resolution HRS Resolution MHz for H or both polarisations 0 250 The HRS Mode for V polarisations HRS Resolution MHz for V polarisation Frequency Settings Observing Mode Settings Time Estimator Settings Frequency Settings Observing made settings Time estimator settings EET ea
53. Area for warning messages about sideband possibly bad frequency settings Caneel j Figure 6 7 HIFI Frequency editor with labeled components Frequency setting can be done with sliders at top or via the table at bottom A full description of the functionality available is available in the HSpot User s Manual The number of spectrometer settings depends on the selection in this case it is for WBS amp HRS being used simultaneously with HRS being used in its nominal resolution mode in band 1a e Rectangular dark blocks to top left and right representing the upper and lower sideband frequencies seen by the WBS and each subband of the HRS e The dark blocks associated with the HRS subbands are sliders which allows the setting of HRS subband offsets within the IF frequency range available Due to the dual sideband nature of the instrument sliding one of these sliders causes the slider in the other sideband to move to illustrate the two frequency ranges that this HRS subband now samples e Below these blocks is a scale which shows the frequency range in GHz The frequencies being sampled by each HRS subband and the WBS can be referenced against this scale We can move this along with the LO slider see Figure 6 7 by click and drag with the mouse e Above the frequency scale appear lines of different colours that represent the positions but not strengths of spectral lines at the frequencies currently showing To see which lines
54. Each of the 14 linearly polarized outputs from the diplexer beam combiner box enters a Mixer Sub Assembly MSA see Figure 2 9 that includes HIFI Instrument Description 2 3 4 Mixer console Thermally isolating structure 4 8GHz isolator 3 mirror system ee Optical beam Figure 2 9 A HIFI mixer sub assembly e a set of three mirrors that focus the optical beam into the mixer e a mixer unit where the incoming signal and LO signal are combined e a low noise IF amplifier plus two IF isolators for bands 1 to 5 that suppress reflections in the cable between the mixer and the amplifier e low frequency filtering for the mixers DC bias lines and e a mechanical structure that thermally isolates the mixer unit at 2 K from the FPU structure at 10 K The Focal Plane Chopper The Focal Plane Chopper FPC is the sixth mirror of the telescope relay optics M6 see Figure 2 10 The chopper mirror is able to rotate in one direction around the centre of its optical surface Tilting the chopper is equivalent to tilting the telescope secondary which moves the beam on the sky The primary uses of the chopper are to steer the beam on the sky and to redirect the instrument s optical beam into the on board calibration sources The beam switch on the sky is currently a fixed parameter for the user The beam switch being 3 on the sky There are two chopper speed regimes available to the user a fa
55. F band Uses the internal loads for reference It is highly recommended that users always use an OFF reference position whenever possible with this mode Description In this reference scheme an internal cold calibration source is used as a reference to correct short term changes in instrument behaviour The HIFI chopping mirror alternately looks at the target on the sky and an internal source of radiation with a typical period of a few seconds This is particularly useful when there are no emission free regions near the target that can be used as reference in either position switch or dual beam switch modes Modes I 1 and I 2 or where frequency switching Mode I 3 cannot be used due to the spectral complexity of the source Since the optical path differs between source and internal reference a residual standing wave structure may remain Additional measurements of an OFF measurement of an emission free region chosen by the user can be used to reduce baseline ripple Such a scheme is robust but has relatively high dead times The total time spent on the OFF position depends on the frequency resolution needed to describe the baseline ripple which may be considerably smaller than the integration time spent on the source The general timeline is illustrated by the following schematic picture Figure 4 6 Telescope iti Pii L im s i Tia ly OFF position T i 1 F 4 i i j i H h source position Sees EHHH fA i E Tuning of t
56. HERSCHEL Eeron Hydrogen Sulphide pa we A a OOF Methanol Y a ACh id Formyl Cation oF fu Dimai Ether aner Methanol Sulphur Dioxide ral del aE Deuce BC j Methanol ED MethylFormate Poe i adil i ia itl nul wo i HIFI Spectrum of Water and ESA HEXOS and the HIFI consortium Organics in the Orion Nebula E Bergin HIFI Observers Manual Update for Start of GT2 Observations HERSCHEL HSC DOC 0784 version 2 3 31 March 2011 Cover image A single sideband spectrum covering the whole of one subband of HIFI towards the Orion nebula superimposed on a Spitzer Space Telescope colour composite of the region from IRAC and MIPS images Credit NASA HIFI Observers Manual Update for Start of GT2 Observations Published version 2 3 31 March 2011 Copyright 2011 Revision History Revision version 2 3 APM DT Update for changes made for the GT2 call including HSpot 5 3 updates Revision version 2 2 APM DT Update for changes made for the GT2 call Revision version 2 1 APM DT Update for changes made starting OT1 observations Revision version 2 0 APM DT Update for initial Open Time call OT1 Revision version 1 1 APM DT Update for initial Open Time Key Projects Revision version 1 0 APM DT Initial version Table of Contents 1 The HIFI Instrument Observer s Manual cece eee ccee cence eeee seca eeca cena ee
57. HIFI data as of version 5 1 of HIPE HCSS Current values are in cluded in Table 5 5 and the beam efficiency at frequencies in between those listed may be interpolated from the values given NOTE Prior to HIPE 5 1 the HIFI final processed spectra in level2 of the data were in Ta not T This means that to go to the main beam temperature Tmb users needed to divide by Nmb ONLY In HIPE 5 1 users have to multiply by N Nmp in order to get to the main beam temperatures Table 5 5 HIFI beam efficiencies Band Freq GHz NA Nmb Band la 480 0 676 0 756 Band 2a 640 0 673 0 752 Band 3a 800 0 669 0 748 Band 4a 960 0 664 0 742 Band 4a 1020 0 662 0 740 Band 4b 1114 0 659 0 736 Band 5a 1116 0 562 0 639 Band 5b 1272 0 557 0 637 Band 6a 1430 0 646 0 722 Band 6b 1600 0 637 0 712 Band 7a 1700 0 632 0 706 Band 7b 1800 0 626 0 700 Band 7b 1900 0 620 0 693 5 5 3 Chopper Calibration In one of HIFI s most used observing modes DBS the internal chopper mirror is used to move the beam to a reference Off position on the sky within 3 arc minutes away from the On target position Since moving the internal mirror changes the light path for the incoming waves the possibility of residual standing waves exists By slewing the telescope so that the source appears alternatively in both On and Off chopped positions the impact of standing wave differences is eliminated to a first order The whole
58. HRS is directly locked to the Master LO the HRS itself has an additional frequency accuracy of 5 kHz for the autocorrelator For the WBS the frequency scale is determined with an internal signal locked to the Master LO For this spectrometer there is an extra frequency uncertainty of 100 kHz The overall HIFI frequency accuracy budget is summarised in Table 5 2 Table 5 2 Frequency accuracy budget Band 1 2 3 4 5 6 7 LO Freq Acc kHz 24 32 40 48 60 70 5 95 5 WBS Sys Freq Acc kHz 120 130 140 150 160 220 250 HRS Sys Freq Acc kHz 29 37 45 53 65 126 151 5 4 3 Determination of Frequency Calibration The objective of the RF frequency calibration is to assign a frequency to a given channel number of the considered spectrometer The techniques will differ for the WBS and the HRS 5 4 3 1 WBS frequency calibration The WBS frequency calibration relies on the use of aCOMB measurement providing narrow emis sion lines at known IF frequencies between 3 9 and 8 1 GHz in steps of 100 MHz The lines are fitted and their positions in the channel scale are translated into a polynomial function giving frequency as a function of pixel number Note that the frequency scale obtained in such a way may not necessarily be linear with channel number Averaging several WBS spectra requires regridding to a common frequency or velocity scale 5 4 3 2 HRS frequency calibration Due to its digital
59. OR files Changed figures 6 19 6 27 and 6 32 to show updated front end for HIFI HSpot instrument settings 110
60. SE DA E T NELI TEASA KLE LET OLES AALS R Jt rel a E A ERE LE AEE Fat IN OA EE fet at a 1895 0GHz 1896 0GHz 1897 0GHz 1898 0GHz 1899 0GHz 1900 0GHz 1901 0GHz 1902 0GHz 1733 1303 1313 1323 1833 1543 1853 1863 1873 1833 1893 Local Oscillator Frequency GHZ Redshift Reset Redshift o 000015 Reset all frequencies Frequency Selection Type JE Line sali Transition UL Observed GHz Rest GHz BS m cs x 3 8 x m eos 1301 151 HRS2 mao Hrm ed E 1893 687 7 i HRS 2 Ia No Lines z No Lines z M Warning messages mSS Cancel Figure 6 9 In this example we see that on the CS 39 38 line has been chosen for the WBS which is available using mixer band 7b A mouse click on another line in the resulting lower sideband window reveals there is also an interesting water line nearby Pulldown menus in the table on the HRS1 line have been used to place this water line in the HRS1 subband Note that the sideband checkbox next to the line transition menus is unchecked NOTE For band 6 or 7 measurements the IF frequency bandwidth of the sidebands is 2 4GHz rather than 4GHz 78 Using HSpot to Create HIFI Observations When the appropriate settings have been made the user clicks OK and this completes the frequency settings More information on the frequency editor and editing and inclusion of the lines that appear in the planning tool can be found in the HSpot User s Manual 6 2 1 3 Choosing the
61. aeeeueeeneeeenees 1 1 1 Purpose of this Document cens ea E eE A E AR ES EE A EERS 1 1 2 Preparing HIFI for Operations sss ssiroi iess opeis enes Eu roei Ios pE PRUE SSPE PESTRE 1 1 3 Acknowledgements sectiei nene Ss ieni oee sige cesta cues EIERE E EER EEE RE EEE 2 2 HIFI Instrument Description s is siie ee E bon Jags a E REE odes 3 2 1 Instrument and Concept ssisrosiresise sonsir ine iert EEE EE E EEE EE 3 21 1 What Is HIPI e esini era ea oana nea a n sa EE PEKAES sess sh Ote ko ebaaeas lt 3 2 12 How Does HIFI Work setie aranan og dees Eee Er EEA E EE N E E 3 2 2 Instrument Configuratio siropo en i a E ee EE R e E EE 5 2 3 HIFI Focal Plane Unit sssini roneo e eE E ET EEE E EEE EEE S E 6 2 3 1 The Common Optics Assembly cece eeeceeceeeceeeeeeeceeeen essa eeea sean eeaes 7 2 3 2 The Beam Combiner Assembly Diplexer Unit 0 cece eeee teens 8 2 3 3 PILE Mixers onr vastus ap eat aa A jos pete dah andes ede EEEE 9 2 3 4 The Focal Plane Chopper 0 0 cccecceeceeeceeeceeeceeeca cece seca seus eens eeneeeeeees 10 2 3 5 The Calibration Source Assembly 0c cece ceeecseecneece cece cena ceneeeneeeneees 11 2 4 The HIFI Signal Chain cosis inio esserne er e eret a i rE oE ESETE y Ear 11 2 5 HIFI Spectrometers irori e n E a E E E emote S58 12 2 5 1 The Wide Band Spectrometer WBS ssssssesesssesessssesesrererrrrsrsseresesrereee 12 2 5 2 The High Resolution Spectrometer HRS sssess
62. aneous spectrometer bandwidth 4 GHz Spectral features are then likely to have a different gain response depending on whether they are from the upper or lower side band The ratio of these gains is referred to as the sideband gain ratio For equal responses to upper and lower side band frequencies the side band ratio is 1 or a normalized sideband gain ratio of 0 5 However gain slopes lead to sideband gain ratios deviating from unity this is particularly true at some mixer band edges or IF spectrum edges where the dual frequencies in the spectrum come from sky frequencies separated by up to 16 GHz The side band ratio can not easily be measured in flight although checks have been made across the IF band and was measured in the laboratory prior to flight using gas cell measurements This also requires a full understanding of the molecular gas that was surveyed A full exploitation of the gas cell measurements of a frequency survey of methanol lines has yet to be completed and the accuracy is still relatively poor relative to calibration requirements see Figure 5 16 Side band ratio G ocs wee L 42 Co J 5 m a Hy z x i G i CH CN y 1 2 a 4 P e I ji ji t z f ie i I x G a f p i M GA EES E A ae la 1b 2a 2b 3a 3b 4a 4b 5b 6a 6b 7a7b OO Ee VO a en a a E a 500 1000 1500 LO frequency GHz Figure 5 16 Measured side band ratio from on ground gas cell measurements 68 HIFI Calibration
63. as you like each Once the results look reasonable click OK on the bottom of the HIFI pointed AOR window Add Comments if you want you can add comments to the AOR such as notes on possible observing date constraints click on the Add Comments button and fill in additional comments Visibility if you are interested in knowing when during the mission that the AOR is visible then click on the Visibility button gt visibility periods are shown in another window Ones alii twte ta cbones eiie O om Cw HIFT single point Observation window your AOR is ready and labelled and should appear in the list of observations currently being displayed on the main window see Figure 6 25 87 Using HSpot to Create HIFI Observations Instrument Settings Mixer settings Redshift selection Mixer band 7b Radial Velocity optical mis Save einen eang Low limit GHz i732 Optical redshift 10 00 m High limit GHz i3018 Frame LSR X Spectrometer choice Select the spectrometer to use wes amp HRS WBS Resolution MHz 1 10 Separate setup for each polarisation of HRS sub bands No r The HRS Mode for H or both polarisations Nominal Resolution z HRS Resolution MHz for H or both polarisations fo 250 The HRS Mode for V polarisations Nominal Resolution HRS Resolution MHz for Y polarisation fo 250 Figure 6 19 Instrument setup screen for Exam
64. band and are listed in Table 5 4 The following procedure has been followed e Procedure When the polarization is to be measured at a specific point the observation is carried out with the point placed halfway between the two directions of receiver alignment For point sources this casts the same amount of radiation on each channel and to date does not appear to lead to any false polarization signals at least at a level of accuracy of about 2 e For an extended source however beam misalignment and pointing leads to a different portion of the source being imaged onto the H and V receivers This expresses itself in the following way If the source is viewed at two epochs spaced precisely half a year apart the portion of the scene viewed by the H and V channels is reversed as the telescope views the source at a sky rotation differing by 180 degrees on these two occasions If the brighter part of the source is imaged onto the V channel at the first epoch it will be imaged onto the H channel at the second epoch The source will appear to be linearly polarized but with the direction of polarization rotated by a relative angle of 90 degrees on the two occasions This false polarization distinguishes itself by this reversal of polarization at half year intervals A genuinely polarized source produces a rotation in the direction of polarization over a period of one quarter of a year i e a rotation rate twice as fast as the change in telescope rota
65. bed in a beam dump Interferometer 1 Interferometer 2 Beamsplitter LO Injection Diplexer LO Injection Figure 2 8 Beamsplitter and diplexer mixing with sample diplexer unit At high frequencies where LO power is scarcer a Martin Puplett diplexer is used for LO injection see Figure 2 8 As in the beamsplitter channels the first beamsplitter creates two beams containing LO and signal power in orthogonal polarizations However in this case the second beamsplitter is replaced with a polarizing Michelson interferometer that rotates the LO beam polarization relative to that of the signal beam creating a linearly polarized output In this manner the coupling of both the LO and signal powers to the mixers is high 95 or better although diplexer scanning mechanisms are needed for frequency tuning 2 3 3 HIFI Mixers 2 3 3 1 Device Technologies The mixers at the heart of the Focal Plane Unit largely determine the instrument s sensitivity For this reason the mixer technologies used in each band have been selected to yield the best possible sensi tivity In particular a range of Superconductor Insulator Superconductor SIS mixer technologies are being used in the lowest 5 frequency bands covering 480 1250 GHz see Refs 2 3 4 and 5 while the top two bands covering 1410 1910 GHz see Refs 6 and 7 incorporate Hot Electron Bolometer mixers HEB mixers 2 3 3 2 The Mixer Sub Assembly
66. calibration is made by comparison of the source measurement with measurements of hot and cold blackbody loads internal to HIFI However sources do not usually fill any of the HIFI beams and a correction usually in the form of an aperture efficiency is needed For more details on the calibration procedure see Chapter 5 The main noise contribution for measurements is from to the instrument itself This noise level is referred to as the system temperature Tsys 2 2 Instrument Configuration Referring to Figure 2 3 HIFI has five hardware sub systems the Local Oscillator and Focal Plane Sub Systems the Wide Band and High Resolution Spectrometers and the Instrument Control Unit Within the Local Oscillator Sub System a tuneable spectrally pure 24 36 GHz signal is generated in the Local Oscillator Source Unit This signal is then frequency multiplied upconverted to 71 106 GHz amplified and further frequency multiplied by different factors for each of the LO chains to the desired RF frequency in the Local Oscillator Unit The result is a spectrally pure LO signal with a tuneable frequency and power level Fourteen multiplier chains cover 480 1910 GHz 625 157 microns with two chains for each of the seven Focal Plane Unit mixer channels The chain feeding the lower frequencies of the band is labelled a and for the higher frequencies is labelled b leading to the naming of mixer bands as la 1b 2a etc HIFI Instrument Descr
67. ccurate baseline removal with no trade off with line intensity calibration accuracy by optical effects standing wave differences will cancel via dual chop motion The internal chop measurements and small telescope motions mean that the science target is viewed nearly 50 per cent of the time This is typically more efficient than the position switch method Mode I 1 Fast chopping Mode I 2a is best at lower spectral resolutions Disadvantages and alternatives Relative timing between the internal chopper and telescope nodding at all of HIFI s integration times is crucial to avoid residual ripples and the constraints cannot be tested and adjusted until the commis sioning phase Also the direction of the chopper motion on the sky depends on the roll angle of the spacecraft which slowly changes on orbit Thus the chopper motion is only predictable when fixing the data and time of an observation which is not advised in order to allow normal scheduling flexibil ity meaning that the mode should be generally restricted to objects with a size below 3 arc minutes in all directions Otherwise the observations should use position switch frequency switch or load chop modes Modes I 1 I 3 or I 4 User Inputs Target ON position chop rate fast or normal LO band and frequency minimum and maximum goal frequency resolution of the calibrated data spectrometer usage and total observing time or noise limit at the lowest goal resolution It is p
68. ce fixed or moving over a large frequency range typically gt 20GHz by the use of multiple LO frequency settings during the observation But can also be used to get smaller ranges where the different LO settings allow the distinguishing of spectral features into upper and lower sidebands Uses the internal HIFI loads for reference during the measurements Description This mode behaves in a similar fashion to the load chop single point mode I 4 The reference used is from the internal cold load and measurements are for every LO frequency of the scan typically every 0 5 to 1 GHz or so e effects An OFF position should be used that can be up to 2 degrees away from the target where similar measurements can be made to allow a double differencing that removes the effects of light path differences of sky to mixer and sky to internal load The mode inherits similar advantages and disadvantages to mode I 4 The pattern of spatial and main frequency groupings is similar to mode IIJ 2 also see Advantages Most useful for line observations of objects that are in regions of extended emission and where a fast referencing scheme is preferred e g using bands 6 and 7 Particularly useful for sources where 43 Observing with HIFI there is expected to be high line complexity The use of the OFF position is highly recommended for removing standing waves Disadvantages and Alternatives The scheme has similar disadvantages to the singl
69. ce is used for the command inter face The High Resolution Spectrometer HRS With the HRS high resolution spectra are available from any part of the input IF bandwidth 4GHz or 2 4GHz in band 6 or 7 The HRS is an Auto Correlator Spectrometer ACS that can process simulta neously the 2 signals coming from each polarization of the FPU It is composed of two identical units HRS H and HRS V Each of which includes an IF processor a Digital Autocorrelator Spectrometer ACS and associated digital electronics plus a DC DC converter not discussed here The HRS pro vides capability to analyse 4 subbands per polarization placed anywhere in the 2 4 or 4 GHz input bands coming from the Focal Plane Unit FPU The two units of the HRS can be used to process the same 4 sub band frequency ranges in each of the two polarizations provided by the FPU thereby reducing the integration time and providing redundancy Both units of the HRS operate at the same time and it is possible to look at either IF with each of the HRS spectrometers 2 5 2 1 Overview of the HRS Subsystem In each HRS unit the ACS processes the signals coming from its associated IF see 9 Each 230 MHz band width input is digitized by a 2 bit 3 level analogue to digital converter clocked at 490 MHz The digital signals are analysed with a total of 4080 autocorrelation channels It is possible to configure the HRS to provide 4 standard modes of operation as given in Table 3 2 For e
70. ch channel they create an image of the telescope secondary within the beam combiner assembly see Section 2 3 2 This image has a large Gaussian beam waist to minimize diffraction losses and a frequency independent size to simplify visible light alignment The seven local oscillator beams from the Local Oscillator Unit enter the FPU through windows in the cryostat Using 7 sets of five mirrors the Cold Local Oscillator Optics re image the LO beam waists at the FPU input to waists in the diplexer box that match those produced by the channel splitting optics The Beam Combiner Assembly Diplexer Unit Within the beam combining assembly each of the 7 signal beams is combined with its corresponding local oscillator beam creating two linearly polarized beams per channel referred to as Horizontal H and Vertical V beams Each of these 14 beams is then directed into a Mixer Sub Assembly HIFI Instrument Description At low frequencies where significant LO powers are available the combining is done with polarizing beamsplitters As seen in Figure 2 8 one beamsplitter is placed at the intersection of the LO and signal beams creating two mixed beams one contains the horizontally polarized signal beam and the vertically polarized LO beam while the second contains the inverse Each of the mixed beams then hits a second beamsplitter which is oriented to reflect 90 of the signal power and 10 of the LO power the remaining power is absor
71. cies window pops up Eilio oi eE ear Ee Ee gt the Frequency Editor window pops up On the Frequency Selection table gt we will put the H 0 lines on either sides of an LO frequency of order 652 GHz then adjust select H20 line in the line scroll down menu Tick the Upper Sideband box select the corresponding transition of interest in USB in the present case the ortho H20 1 1 0 1 0 1 line gt the slider automatically moves to locate the chosen line slightly offset from the centre of the WBS band LOF becomes 652 26 GHz see Figure 6 28 Check all the desired lines targeted plus bonus lines are within both side bands If not move the frequency sliders in order to do so Avoid locating lines in the middle of the WBS sub band gt in the present case the CO 6 5 shown in green here and H 0 634 541 lines lie towards the upper edge of the USB so we have to slide to a higher LOF 653 45 GHz see Figure 6 29 rs Cllaions Ol On the Frequencies window click Done Observing mode setting Click the set the point mode button Select Dual Beam Switch tab For these observations we do not want to select fast chop or continuum measurements which are most useful for very bright objects and very accurate continuum 92 Using HSpot to Create HIFI Observations rather than spectral line measurements Leave as default Ce Gs Time Estimator settings Click the
72. cification The mixers act as detectors that feed either or both the two spectrometers on HIFI An instantaneous frequency coverage of 2 4GHz is provided with the high frequency band 6 and 7 mixers while for bands 1 to 5 a frequency range of 4GHz is covered The data is obtained as dual sideband data which means that each channel of the spectrometers reacts to two frequencies separated by 4 8 to 16 GHz of radiation at the same time see Section 2 1 2 and Section 3 1 For many situations this overlap ping of frequencies is not a major problem and science signals are clearly distinguishable However particularly for complex sources containing a high density of emission absorption lines this can lead to problems with data interpretation Deconvolution is therefore necessary for the data to create sin gle sideband data This is especially important for spectral scans covering large frequency ranges on sources with many lines see Chapter 6 There are four spectrometers on board HIFI two Wide Band Acousto Optical Spectrometers WBS and two High Resolution Autocorrelation Spectrometers HRS One of each spectrometer type is available for each polarization They can be used either individually or in parallel The Wide Band Spectrometers cover the full intermediate frequency bandwidth of 2 4GHz in the highest frequency bands bands 6 and 7 and 4GHz in all other bands The High Resolution Spectrometers have variable resolution with subbands samplin
73. ctral scan AOT is treated somewhat differently to the pointed and mapping AOTs Since we want a specific instrument setup to take information efficiently across as wide a frequency range as possible the WBS is used The WBS is to be stepped across a frequency range that the user requests The only limit to this frequency range is what is available to the chosen mixer band If data rates permit the HRS may be run in a parallel mode typically in high resolution mode for additional information Users should NOT rely on HRS measurements being available for spectral scan science measurements The main choices for the observer are the frequencies over which data is to be taken and whether the data is to be taken using a frequency switch or dual beam switch mode See Figure 6 14 81 Using HSpot to Create HIFI Observations LJ HIF Spectral Scan Unique AOR Label HScan 0000 Target None Specified Modify Target C Target Ust Number of visible stars for the target None Specified Mode Settings Settings Mixer band la v Range Full Band v Range From GHz ea Range To GHz S59 Redundancy 4 WBS Selection Both v Only the WBS is used in this mode Observing Mode Settings Time Estimator Settings Observing mode settings Time estimator settings Set the observing modes Add Comments Figure 6 14 The spectral scan AOT setup window One parameter choice that is peculiar to the spectral scan mod
74. cuted Sequence parameters Backend readout period on source 4s Number of switch cycles on source 17 Number of pointing cycles 4 Interval between load measurements 1800s This corresponds to a chop phase length of 4 00s or a chopper frequency of 0 12Hz respectively Gyro calibration A posteriori relative pointing improvement can be obtained from a gyro calibration taking 137s every 582s Observing mode performance Noise predictions Fluctuation bandwidth LSB 1 62 MHz 0 008 K 0 008K Observing time without initial slew 1182s On source integration time 533 1s OFF integration time 533 1s Overhead 115 8s Total time efficiency 90 2 Total noise efficiency 20 7 Drift noise contribution 8 00 The system noise temperature at 498 GHz is 166 K in the lower and 166 K in the upper sideband Noise values are given on a polarization averaged single sideband main beam temperature scale of a 43 5 beam with a main beam efficiency of 75 5 gt Save messages Cancel Figure 6 17 Sequence parameters including on off cycles and number of switch cycles are available from the Messages button For chopper modes the frequency of the chopper is also reported Statistical in formation indicates the efficiency of the observation and time spent on overheads 6 3 Example HIFI Single Point Observation Setups HIFI has several observing modes for observing point sources The user s choice of observing mode is typical
75. d 7b The latter was box car smoothed by 5 channels r T rrr TT T TT rtiiit rear eer 4 2b tat dt Leila n 1468 8 1469 0 1469 2 14694 1469 6 1469 8 1470 0 1855 2 1855 4 1855 6 1855 8 1856 0 1856 2 1856 4 Isbfrequency GHz Isbfrequency GHz Figure 4 12 Standing wave residuals in Bands 6a left and 7b right These electronic standing waves have periods of 300 MHz but they are not sine waves and FitHi fiFringe can only approximately remove them A promising method current matching technique is being developed to remove these waves in the pipeline As for the presence of these waves the following general guidelines can be given e Band 6b is most stable and is least affected e FastDBS mode spectra tend to show weaker standing waves than slow chop DBS mode spectra e In Band 7 spectra taken with the vertical polarization spectrometers tend to show stronger waves than from the horizontal polarization Sometimes this effect is very strong See e g Figure 4 13 1719 0 1719 5 1720 0 1720 5 1721 0 Isbfrequency GHz Figure 4 13 Standing wave pattern in the Level 2 in Band 7a for WBS V red and WBS H blue 47 Observing with HIFI 4 4 2 Position Switch Frequency Switch and Load Chop Modes Non DBS observations show rather strong residuals in Level 2 spectra An effort is under way to pro vide alternative processing of HEB band observations such tha
76. d to provide processing up to the point of instrument artifact removal level 1 Immediately available as products from the Herschel pipelines for users are level O raw and level 1 data processed All data production and handling is done within the Herschel Common Science System HCSS environment before placing the full pipeline results into the Herschel Science Archive HSA Further processing of data is possible via the Data Processing component of the HCSS or via export to other software systems by the user We provide here a minimal description of pipelines and data products Significant documentation on the pipelines running pipelines interactively and analysing HIFI data using the HCSS are provided when users download the HIPE software system Substantial documentation is provided within the download Users are recommended to use the web interface to obtain public data from the HSA to learn about the structure and format of the data provided Level 0 data Raw telemetry data as measured by the instrument minimally manipulated and put into the mission data base archive often sorted and corrected for small errors Typically readings are in binary units versus detector pixel number Level 1 data Detector readouts calibrated and converted to physical units as much as possible in strument and observatory independent In principle level 1 data processing can be done without hu man intervention For HIFI these are individual spectral sca
77. directly impacted observations of the 557 GHz water line There are very narrow S5OOMHz regions in LO tunings where the spur seems well behaved and one could in principal take a relatively clean spectrum How ever it is not clear how stable this safe zone was over time We previously recommended that users try to use band 1b and place the water line in a lower sideband Recent improvements in the operation of HIFI have allowed this spur to now be removed and users may now use this spectral region free of spurs as of Herschel operational day OD474 see HIFI band la spurs Figure 5 3 illustrates the spurs around the water line in Band la prior to the improved operations in late 2010 Tok bat fo bh ied et le lobia led a oe 2a alien aaa i be eal af ole ao 6 Ni flux K potbitititiitistis titted tl gc ae Oe A aa Pf ve E D ETE 4000 4500 5000 5500 6000 6500 7000 7500 8000 frequency MHz T L Figure 5 3 Spectra taken from 2 different LO tunings in 1a The grey plot is from a tuning of 549 3 GHz and the spur wipes out not only the subband in which it resides 2 but the entire spectra due to the crosstalk At 550 4 GHz however yellow trace the spectrum is well behaved aside from the spur in the second subband 56 HIFI Calibration 5 4 6 3 Spurs in Band 4b Water at 1113 GHz is occassionally corrupted by a spur that appears between LO tunings of 1090 GHz and 1108 GHz However unlike the band la
78. ds the Frequencies window Figure 6 6 where we can add the frequencies we want to work with To add a frequency setting click the Add button This brings up the Frequency Editor window A setting that already exists can be modified Select the frequency setting to modify by clicking on its line description appearing in the Frequencies window and then clicking the Modify button the Frequency Window pops up with the old setting in it which can now be modified Frequencies Actions Add LOF Number Local Oscillator Frequency Line Transition Frequency Figure 6 6 HIFI Frequencies window Frequency Editor The Frequency Editor window contains much information see Figure 6 7 From top to bottom we have the following 76 Using HSpot to Create HIFI Observations x 4GHz sideband Frequency Editor 4GHz sideband Lower Sideband LO Frequency Ers Upper Sigeband Sliders allow positioning of HRS 7 sub bands within 4GHz windows Zoomed SOR fre queries AE Sea RTT eR TRTTR A REC om ATH Mere OTOA EIT Or CGT scale 481 00Hz 483 0GHz 485 0GHz 487 0GHz 49QGHz 491 0GHz 493 0GHz 495 0GHz s s Local Oscillator Frequency OHD 5 LO frequency Resshin Reset frequency scale whole Redan Pools Raset ait tieqvencias Positions of spectral lines slider band Frequency Selection Observed GHz Upper ower sideband selection for sky lines Default ticked is upper
79. e intermediate frequency bandwidth 4GHz In other words different sky frequencies are added to different sky frequencies when the LO is shifted a bit thus adding constraints to the problem by adding redundancy see Figure 7 6 Power ly VLo2y Figure 7 6 Redundant LO settings Figure 7 6 above illustrates this Here the two sidebands are overlaid on the sky frequencies The LO has been placed at n LO1 n LO2 and n LO3 By placing the LO in these positions the point x in the lower sideband is added variously to y1 y2 and y2 Likewise with each shift of the LO y1 is added to a different value in the lower side band and likewise y2 and y3 making new paired sums In this way constraints as to the details of the underlying sky spectrum are added with each LO setting With added constraints the problem becomes an inversion or minimization problem Generally speak ing a sky spectrum is sought in both the upper and lower sidebands that can reproduce as closely as possible the double sideband observed spectra Typically this is done in a wide band survey where the LO is stepped over a range such that a frequency will appear multiple times in the two sidebands The optimal solution of the problem is the sky model that minimizes the error the Chi square of the difference between the observed double sideband spectra and predicted double sideband observations based on the sky model The more LO positions that are covered with good S N
80. e is the redundancy parameter This indicates the number of different frequency settings made for each 4GHz or 2 4GHz in bands 6 and 7 available to the WBS spectrometer With a higher redundancy a greater fidelity is possible in the data processing stage where a deconvolution algorithm is used to create a single sideband spectrum from the many dual sideband measurements see Chapter 7 However with higher fidelity comes less efficient observations and there is some cost in time As a rule of thumb higher redundancy 6 or more is needed for sources that are expected to show a high density of spectral lines in the range of frequencies being surveyed The available options for the dual beam switch and frequency switch modes are as for the point source case 6 2 2 2 Setting Up Time Estimator Goals The time estimator setup button is at the bottom right of all HIFI observation AOT windows The user can get a time and noise estimate for selected data resolutions and a seed noise or goal time The resolutions can be put in velocity km s or frequency MHz units The choice is by a pulldown 82 Using HSpot to Create HIFI Observations menu at the top of the time estimator screen The time estimator can also have a goal to take a certain time the user puts in a seed value or reach a certain noise level The goal of Time in seconds or Noise in Kelvin is also available as a pulldown menu at the top of the time estimator setup window
81. e met in a way that the drift term in the total noise is always less than the radiometric term Disadvantages and alternatives An emission free area within 2 degrees of crowded fields or regions of extended emission may be difficult to locate for the OFF reference position to be used This is especially true for regions towards the Galactic Centre and around popular star forming regions If the closest emission free region is beyond 2 degrees and mapping modes AOT II are undesirable then a mode with load chop Mode 1 4 or frequency switch Mode I 3 may be more desirable The frequency switch mode may be more efficient if baseline effects such as standing wave ripples can be ignored in the case of very narrow lines where even a distorted baseline can be approximated by a simple linear profile across the line If the astronomical source to be observed is smaller than 3 arc minutes DBS Mode I 2 observations are preferred because they require only rare slews and contain an inherent baseline correction If the timing constraints from the system stability are not met it is easily possible to arrive at an un certainty of the calibrated data that is dominated by drift noise instead of the radiometric noise In general the resulting timing constraints do not guarantee accurate continuum level derivation Obser vations requiring accurate continuum levels should be acquired with modes making optimum use of the internal chopper e g Mode I 2 o
82. e point load chop mode see Section 4 2 1 4 The light path difference of load to mixer and sky to mixer means that residual standing wave differences typically remai This can be mitigated with the use of a reference OFF position measurement which is of an area free of emission Continuum measurements can not be made with this mode without an OFF position measurement to calibrate the baseline Mode III 2 is preferable for measurements where the baseline continuum is needed to be accurately measured User inputs The user has choice of frequency range within the mixer band frequency range chosen partial or full band The user can choose a redundancy of between 2 and 12 Higher values increase the fidelity of the final single sideband spectrum expected from the data reduction of the mode but also make the mode less efficient The position of the reference OFF is a choice of the user within 2 degrees of the target Data calibration Data reduction follows that of the point load chop mode see Section 4 2 1 4 for each LO frequency used in the scan This is followed by the deconvolution of the set of the calibrated double sideband spectra into a single sideband spectrum Sideband deconvolution is provided via a data software task within the HIPE software environment and must be run interactively by the user after each double sideband spectrum has been processed More information on the sideband deconvolution software is noted in Chapter 6 4 3
83. e when increasing the goal resolution When computing the total data uncertainty different values are obtained when one compares the total power level with the radiometric noise or only the line structure removing a zero order baseline Moreover different values are obtained when we consider only structures on a bandwidth of 1 GHz or over the full backend bandwidth The first is applicable when an observation is only directed towards a single narrow line while the latter one will be needed when observing very broad lines that cover more than one WBS subband or when lines are needed to be located at edges of the IF The timing and sequencing of observations is based in large part on the listed stability times Instru mental drifts over time lead to extra noise which can be mitigated by frequent measurements of a ref erence see Chapter 4 where the different reference schemes available to HIFI are discussed Obser vations requiring accurate measurement across the whole or large fractions of the IF bandwidth e g broad lines due to rotation in observations of galaxies are subject to faster drifts This is taken into account by HSpot when determining the optimum observing sequence for an observation and when the timing scheme for 1GHz bandwidth is un checked 26 Chapter 4 Observing with HIFI 4 1 Introduction For HIFI three Astronomical Observing Templates AOTs are available e AOT I Single Point for observing science targets at o
84. ear devices in that the current out is not directly proportional to the voltage across them in fact their current voltage curves have similarities to those of diodes This allows amplification of the mixed signals of the incoming radiation and an on board local oscillator In particular the beat frequency f fLo between each of the incoming source frequencies f and the single Local Oscillator frequency fio HIFI Instrument Description Intermediate Frequency The beat frequencies produce the so called Intermediate Frequency IF of the instrument Further amplification is made of these intermediate frequencies and for HIFI filtering allows the detection of IFs of 4 to 8GHz which is done in the HIFI spectrometers 2 1 2 2 Double Sideband Data In creating the intermediate frequency it should be noted that a given IF value e g 5GHz can be obtained from a source frequency that is either 5GHz higher or 5GHz lower than the local oscillator frequency If we consider this for a range of incoming frequencies we can see that our spectrometer measures two superimposed portions of an object s spectrum e The portion of the source spectrum 4 to 8GHz above the LO frequency This will be in ascending frequency order from f 9 4GHz to fLo 8GHz This is the upper sideband USB e The portion of the source spectrum 4 to 8GHz below the LO frequency This will be in descending frequency order from fLo 4GHz to fLo 8GHz This is the low
85. east amount of structure possible while at the same time the y residual is minimized A pre selected balance between these two requirements is utilized By only inserting as much structure into the solution as the data warrant MEM produces good results on weakly constrained data sets 107 Pipeline and Data Products Description AEn Omer vi w A SO AA Ea O a s n T7 ee A wl I a a S Tp K 344 Rest frequency GHz Figure 7 7 MEM deconvolution with a small n 1 and large n 7 degree of redundancy using a simulation with a known sky distribution In Figure 7 7 the redundancy is defined as the number of independent LO settings minus one The grey MEM result approaches the black line correct sky spectrum when the redundancy is high A user tool for general observers has been and continues to be developed for use within HIPE to extract scientifically optimal data from HIFI spectral scan observations see observing Modes III 2 and IT 3 Deconvolution is available as a task within HIPE and is found to work well with HIFI data although some data cleanup is generally needed particularly when spurs occur in the data of spectral scans at particular LO settings 108 Chapter 8 References 1 Jackson B D Wildeman K J and Whyborn N D on behalf of the HIFI Focal Plane Consor tium The HIFI Focal Plane Unit 2002 Proc 13th International Symposium on Space Terahertz Techn
86. ectral scan usually with an integration time doubled compared with other fre quencies However at those frequencies the data may have to be discarded for an optimum SSB deconvolution Only bands 4a 4b and 6a are concerned by this situation It should also be noted that there can be sensitivity issues at the upper end of 7b above 1898 GHz despite having enough LO power the tuning algorithm is not yet fully stable there 22 HIFI Scientific Capabilities and Performance 3 5 3 Sensitivity Variations Across the IF Band The 2 4GHz in bands 6 and 7 or 4GHz all other bands bandwidth of the spectra obtained out of the instrument are known to have some variations in sensitivity Bands using beamsplitters Here the sensitivity variations are not particularly large across the band This is the case for bands 1 2 and 5 But IF mismatch can occur at some specific frequencies resulting in narrow features of noise excess in the IF see Figure 3 12 Tsys WBS H 1b 606 5 GHz 102 13K 125 TT SA Oa a a 120 115 110 105 100 Tsys K 95 90 85 80 Ween eee eee eee eee ee TOTTI TTT TTT TTT Trp 75 Eedts bse dd brna darad 4000 4500 5000 5500 6000 6500 7000 7500 8000 frequency MHz Tsys WBS V 1b 606 5 GHz 81 10K PTT TTT rrp 120 Tsys K wo ul PERTTI TTT TTT TT TT TTT thotitii tb B re TA Ce ce E A T e a a S L 4000 4500 5000 5500 6000 6500 7000 750
87. ed A Complete band la coverage B Complete band 1b coverage To setup up our observation do the following steps for the first AOR the band 1a full coverage 1e R n HSpot 2 Choose target Targets Menu gt New Target 2 1 Enter target name IRAS16293 2422 2 2 Resolve the name using SIMBAD option and fixed target tab Alternately you can input the coordinates directly 2 3 Once resolved acknowledge source coordinate by clicking OK 3 Setup observations Observation Menu gt HIFI spectral scan 3 1 Setup A Instrument setting mixer band scroll down menu choose band la Range full band we need to cover all of band la 100 Using HSpot to Create HIFI Observations Redundancy 6 this indicates how many LO frequency settings there will be within the 4GHz IF frequency range So a setting of 6 indicates data taken every 750MHz Higher redundancy produces higher quality results but at the cost of more observing time Both WBS polarizations are on the default see Figure 6 36 Mode setting We will use the Dual Beam Switch reference mode No fast chop no continuum to be used Time Estimator settings Select estimate to be done with a time goal in the corresponding scroll menu gt e g here Time Input the required time in the table below e g 3000 sec For a spectral scan a single scan can take a lot of observing time If the input user time is less than than the minimum time possible for
88. election The tab for the the dual beam switch mode has been clicked to display what is in the figure 79 Using HSpot to Create HIFI Observations KSobserving Mode Settings x Observing Mode Settings Choose one of the modes below Dual Beam Switch Load Choo 1 Freauency Switch No mode selected Position Switch Reference Position Specifications Ref Type By offset By position Yes RA offset arcmins fo 00 o gt C Ho Dec offset arcmins foo RA degrees poo Deo degrees poo rti e pE F a OC SNSSCNCNCNC Choose Position Cancel Figure 6 11 The position switch options available when clicking on the point switch tab If the OFF posi tion is to be given absolutely then the by position radio button should be selected Clicking on Choose Position then allows selection of a position in a similar way to target selection in HSpot Mapping Modes To select a mapping observing mode click on the Mapping Mode Setting button at the bottom centre of the mapping mode AOT window Selecting the appropriate tab allows either raster or On the Fly scan using a OFF position reference mapping to be selected see Figure 6 12 ra Observing Mode Settings ES Observing Mode Settings Select a mapping mode OTF mapping wiload chop OTF mapping w Freauency Switch DBS Cross Map No mode selected i Ons THE Fly mapping DBS Raster Mapping On The Fly mapping
89. encies Frequency Selection Ss Line Transition Observed GHz Rest GHz was v en ict x M 1300 359 1900 53 HRS 1 v No Lines x No Lines Mid es 2 LES Lines Z No Lines Mia A Cancel Figure 6 21 The H20 331 404 line is shown available under the dark area to top left x i Frequency Editor Ir Lower Sideband LO Frequency fizs73ss Upper Sideband RS 2 IF 3 85 RS 2 IF 3 00 BS ON RO VUE OANNN A AAA RR IEAA EAA DEDEDE OLENE AR SAA ENERGIA CII C vp 1900 5369 jel 1894 0GHz 1895 0GHz 1896 0GHz 1897 0GHz 1898 0GHz 1899 0GHz 1900 0GH 3 OC 1733 1803 1813 1823 1833 1843 1853 1863 1873 1883 1893 l Local Oscillator Frequency GH2 r Redshift Reset Redshift 0 000094 Reset all frequencies Frequency Selection Za Transition S Observed GHz Rest GHz BS v en MG M f7 1300 359 1 900 537 RS 1 Iv H20 x 33 08 z 1293509 1893 687 z z 1900 359 1800 537 Cancel Figure 6 22 Final frequency selection for Example 1 with CII position marked Note that the CII line is NOT at the centre of the sideband this is due to the fact that there is slope to the sensitivity within the IF for bands 6 and 7 The position shown is believed to be the best for sensitivity and coverage see the Chapter 3 for details 89 Using HSpot t
90. ent is summarised in Table 3 1 HIFI Scientific Capabilities and Performance Table 3 1 HIFI frequency coverage and band allocation Note that the values presented are Local Oscillator frequencies Each band is further split in two a and b due to the use of two Local Oscillator chains for the lower and upper portions of the frequency range for each band A further 8GHz is available at each end of the frequency range due to the frequency placement of the upper and lower sidebands in HIFI in bands 1 to 5 This is only a further 4 8GHz in bands 6 and 7 Band Mixer type A Lower TA Upper Rw Size e Bandwidth 1 SIS 488 1 GHz 628 4GHz 39 4 0 GHz 2 SIS 642 1 GHz 793 9 GHz 30 4 0 GHz 3 SIS 807 1 GHz 952 9 GHz 25 4 0 GHz 4 SIS 957 2 GHz 1113 8 GHz 21 4 0 GHz 5 SIS 1116 2 GHz 1271 8 GHz 19 4 0 GHz 6 7 HEB 1430 2 GHz 1901 8 GHz 13 2 4 GHz 3 4 Available Spectrometer Setups 3 4 1 3 4 2 HIFI has four spectrometers one Wide Band Spectrometer WBS and one High Resolution Spec trometer HRS per polarization These may all be used simultaneously When all spectrometers are in use frame times are 4 seconds each Shorter frame times are possible when only one type of spec trometer is used 1 or 2 seconds The high resolution spectroscopy modes available with HIFI are most useful for observing faint de tails and to separate adjacent spectral lines from each other The cont
91. er Side band Ratio cece cece cece ee ceeeceeeea seca seca eeee eens ecae een eeneeeeneeee ea 68 5 6 1 IF Spectrum Repeatability Sideband Line Ratios 0 0 0 0 cece ence eee 69 5 7 Summary overall calibration of HIFI and error budget cece cece cence ee ee eee 71 3 7 L Strategy SUMMATY sepsisni T a G apen PRE a Taa A Ea 71 57 2 Error budgets nosire in Bless EEE E E EEEE EEE os 71 6 Using HSpot to Create HIFI Observations 2 0 0 0 essi i s snssss isipo nsere kss roti s 73 Oily OVERVIEW mieren arees ies este ed doit E E I desde poet ohaa EE o NE EE e 73 6 2 HSpot Components for Setting Up a HIFI Observation eee cree ee eeee 73 6 2 1 Working with A HIFI Pointed or Mapping Observation Template 73 6 2 2 HIFI Specttal Scan AOT isiende neses na EEE EO EOS NEE S E Riit 81 6 3 Example HIFI Single Point Observation Setups cece ee cece eee ece eee neeeeeeee es 84 6 3 1 Example 1 Observing the CII line using Frequency Switch in a photodis SOCLIAUION TE GION 25 seen i nao Sud agebeaue cess eussvedi eee deve A ESEE EEROR ETRS 85 6 3 2 Example 2 A Dual Beam Switch DBS mode AGB Observation 91 6 4 Example Setup of a HIFI Mapping AOR 1 0 0 0 ec ee eee ceee ce eeea seca eean sean eens 96 6 4 1 Example 3 Scan Mapping of the Spectral Lines CO 7 6 and CI 2 1 in the Centre Of MIL ernn tie tes esedi st ieee eee E e E E tetas es EEA Sie eS 96 6 5 Example Se
92. er sideband LSB This superposition is illustrated in Figure 2 1 Lower sideband sky Upper sideband sky fihiln Adin lahai washed fragment V Sky Frequency MHz Sky Frequency MHz Mix with LO at 807000 MHz Double sideband view Toil vite nie WN A IF Frequency MHz Figure 2 1 Superposition of upper red in double sideband view and lower blue in double sideband view sideband spectra in a portion of a single DSB spectrum crudely based on Orion cloud spectra taken at 807 0GHz 24 0 20 0 2 0 16 0 2 8 0 4 0 T T T T T T T T 5400 5450 5500 5550 5600 5650 5700 5750 5800 5850 IF Frequency MHz Figure 2 2 Superposition of two separate DSB spectra in blue and red taken at 807 0 and 807 13 GHz respectively Note how the largest line from the lower sideband goes up in the IF band frequency when the LO frequency is increased compare with previous figure while the other two lines from the upper sideband go in the opposite direction In all cases the frequency shift is 0 13GHZ the same as the LO frequency change between the two observations HIFI Instrument Description 2 1 2 3 Consequences of Double Sideband DSB Data For a number of regions where a single strong line of known frequency is the subject of study knowing whether it is in the upper or lower sideband frequency range is easy to determine and so it is easy to assign the correct frequency to the spectrum scale Small LO shi
93. ere the spectrum obtained is compared to the warning now provided in HSpot On top of these spurious signals oscillations in the Local Oscillator multiplier chain can render the mixer sensitive to more than only one frequency resulting in practice in spectral ghosts from other mixing products and an improper intensity calibration of the targeted lines 55 HIFI Calibration flux K usbfrequency GHz Figure 5 2 On the left is the spectrum from the spectral survey at a frequency shown in the HSpot AOT on the right A strong spur is seen in the fourth WBS subband In the HSpot window the fourth subband of the WBS in the upper sideband is shaded in purple and a warning is shown at the bottom of the HSpot screen The user may want to consider whether this is a good frequency setting for the observation and should avoid placing lines of interest in the region of the fourth subband of the WBS 5 4 6 1 Analysis of spurious responses in WBS In general spur positions and strengths have remained similar between the prime and redundant sides and across over a year of data acquisition stretching back to pre launch test activities The spurs that cause the most concern are the ones near important water lines 5 4 6 2 Spurs in Band 1a In La a strong spur originally existed blueward of 548 7 GHz This spur was very strong saturating the detector and rendering the entire 4GHz passband unusable This is unfortunate as it
94. ervations without baseline calibration Many observations will however require a frequency resolution that is finer than the standing wave ripple so that the overhead from the baseline calibration is smaller If the user chooses to opt out of the OFF reference measurement then a residual baseline including ripple is likely to remain and may require removal interactively by the user Modes of the Mapping AOT Il There are four mapping modes available to HIFI The On the Fly observing mode takes data con tinuously as a source is scanned and can use a frequency switch reference a load chop reference or a sky reference while a dual beam switch DBS raster map takes data at set points on a user defined grid A variant of the DBS raster map a small 5 point raster cross map was originally made available but has now been discontinued 36 Observing with HIFI 4 2 2 1 Mode Il 1 On the fly OTF Maps with Position Switch Ref Purpose Used to observe an extended source fixed or moving in one or more spectral lines within a single IF band Allows the choice of a reference sky position within 2 degrees of the target Description The observing mode of OTF maps with position switch reference is in many cases the most efficient observing mode for mapping observations with HIFI Because one reference measurement can be used for several source measurements and little time is lost to telescope motions without data integrations it ca
95. es and Alternatives Not as efficient as OTF mapping and with a beam switch of only 3 arc minutes this is not a good mode to use for large scale maps Limited to 32x32 raster points in a single observation User inputs The user has the possibilities of rectangular map sizes scan length X and cross scan map size Y The cross step can be set at Nyquist sampling or one of a number of set cross step sizes in arc seconds Continuum timing for accurate baseline measurements and fast chopping are selectable Data calibration Each raster map position can be calibrated in the same way as single point dual beamswitch data see Section 4 2 1 2 4 2 2 3 Mode Il 2X Cross Map with Dual Beam Switch currently unavailable Purpose Used to observe spectral lines or continuum in a point source for which the most accurate flux is needed but for which the position or pointing inaccuracy could cause significant error in the measurement Uses sky references 3 either side of the target Note that this mode is currently unavailable pending a fix to its commanding it has had few science observation requests in the Key Project calls Description In this mode a cross grid of set positions forming a 5 point cross are each measured using the dual beam switch method The separation of the cross positions is selectable as pointing jitter to represent the possible worst case pointing error of the observatory currently set at 3 Nyquist
96. f a spectrum that are created by reflections between the telescope structure and the receiver The HIFI intensity calibration uses a new calibration scheme for the planning and reduction of HIFI observations that takes advantage of the lack of an atmosphere and corrects for the effects of standing waves in the combined observations of lines and continuum with HIFI 5 3 The HIFI Calibration Scheme 5 3 1 Internal Load Calibrations Like most other heterodyne instruments HIFI makes use of the two internal loads to provide the band pass calibration sensitivity for each backend spectrometer channel and polarization The effective 49 HIFI Calibration radiation offered by these loads is corrected from the imperfect coupling of the mixer beam to the load apertures These couplings were measured on the ground during instrument level testing The instrument bandpass Yrec and the receiver temperature J ec obtained via the load measurements are provided by Eq 9 and 10 from 10 l Chot Ccold y a mn Me 1 Unett Joett Mi Cooia Z 1 He Chote 2 ER e a Ih etf a loat a lagi thot cold The superscript indicates that the bandpass and receiver temperatures are measured on the internal loads In the above equations c indicates count rates measured on hot or cold loads z a zero frame removal J s indicate the hot and cold load effective temperature measures as meas
97. fixed target tab 2 3 Once resolved acknowledge source coordinate by clicking OK 3 Setup observations Observation Menu gt HIFI single point 3 1 Setup A Instrument setting see Figure 6 27 mixer band scroll down menu choose 2a Radial velocity scroll down menu choose e g optical km s Redshift enter velocity of IRC 10216 gt 26 km s Frame choose in the present case LSR Spectrometer WBS only Frequency setting preliminary gt Prior to the frequency setting it could be useful to import the lines of interest for display in the frequency editor On the Lines scroll menu choose either of the following JPL or CDMS lines to query and import lines from those catalogues For this example we can add the ortho and para water lines which have catalogue labels 18005 H2O and 18003 H20 respectively in the JPL catalog We will also use the CO catalogue number 29001 C 13 0 and H 0 lines in this example catalogue number 20003 H20 18 Make sure to get the lines for ALL the frequencies you want The user can also use Manage Lines in order to import personal lines into the line list The two options here are Import a user defined formatted spectral line file clicking on the Import button Add specific lines clicking on the Add button Frequency Setting gt Once all desired lines have been imported in the line ety Click on the Set the observing Frequencies button gt the Frequen
98. fter sky subtraction left and after interactive fringe fitting and removal right Note the poor edges in the IF spectrum on the right Sine Wave Removed in HCSS Before black Sine Fit green Baseline blue Mask orange After red E 0 2 0 0 0 2 Intensity Offset 0 8 L 1100 1101 1102 1103 1104 AG LSB Freq GHz Figure 4 11 Band 4b observation using Point Frequency Switch showing a strong residual standing wave black Its period 600 MHz and increasing amplitude toward the band edges are those expected for diplexer bands It was fitted with a combination of sine waves using FitHifiFringe green The corrected spectrum red still shows a strongly curved baseline that can be subtracted with a polynomial fit in HIPE 46 Observing with HIFI 4 4 Bands 6 7 HEB mixers 4 4 1 The HEB mixers generate waves with characteristics that depend on the mixer current level but since there is a dependence on LO power which may not be stabilized between ON and OFF spectra both electronic and optical standing wave residuals can be mixed together Data taken with all observing modes analyzed so far show residuals at Level 2 where the non DBS modes tend to show larger and more complex residuals DBS Modes Bands 6 7 are less stable than bands 1 5 and Level 2 data occasionally show residual waves Examples are shown in Figure 4 12 for portions of Bands 6a an
99. fts However for cases where it is not known a priori which spectral lines are in which sideband the simplest way to determine this is by shifting the LO frequency An increase in LO fre quency will lead to USB features moving to lower IF frequencies and LSB features moving to higher IF frequencies see Figure 2 2 It then becomes clear which sideband and frequency the features are in Deconvolution Even the above technique becomes impossible for regions where there is a high den sity of spectral features In such cases the chances become quite high that USB features and LSB features will overlap And the shifting of the LO may only lead to other feature overlaps For this case deconvolution techniques have been devised see Chapter 7 These allow large regions of frequency space to be sampled by many positionings of the LO frequency A reconstruction of the spectrum single sideband SSB can then be made 2 1 2 4 The HIFI Flux Units Antenna Temperature Sub mm astronomy derives many of its units from radio astronomy The standard unit for measuring the power received is antenna temperature T which is defined by kT power received per unit frequency If the intensity is constant across the whole beam then the antenna temperature is equivalent to the brightness temperature the temperature a blackbody needs to be in order to see the observed intensity at a given frequency This is a particularly convenient scale to use since flux
100. g up to half the 4GHz intermediate frequency range Subbands have the flexibility of being placed anywhere within the 4GHz range How Does HIFI Work Sub mm continuum radiation is best detected with bolometers which act like thermometers measur ing the heat coming in and translating it to integrated intensities Line radiation is much more difficult to detect There are no amplifiers available to amplify the weak sky signals at sub millimeter wave lengths For lower frequencies there are however good amplifiers available which can be small low in energy consumption and weight These are thus very suitable for a space observatory 2 1 2 1 The Mixers The solution is thus to bring the signal down in frequency without losing its information content This is accomplished through heterodyne techniques in which the sky signal is mixed with another signal Local Oscillator very close to the frequency of interest In performing such mixing of signals the resulting signal is of much lower frequency while still having all the spectral detail of the original sky signal Modern mixing devices such as SIS semiconductor insulator semiconductor mixers or hot electron bolometer HEB mixers not only perform the mixing but can also amplify the signal making them eminently suitable for instruments like HIFI Mixing The mixers used by HIFI are at superconducting temperatures the HEBs are on the border of normal and superconducting They are non lin
101. he deconvolution yields flat baselines with neither ringing nor any added repetitive noise structures 4 2 3 2 Mode Ill 3 Frequency Switch Spectral Scan Purpose Used to observe a point source fixed or moving over a large frequency range typically gt 20GHz by the use of multiple LO frequency settings during the observation But can also be used to get smaller ranges where the different LO settings allow the distinguishing of spectral features into upper and lower sidebands Uses frequency switching for reference Description This mode behaves in a similar fashion to the DBS version of mode III 2 The reference used is from a nearby frequency using a small step frequency away from each of the main steps that are taken 42 Observing with HIFI every 0 5 to 1GHz The mode inherits similar advantages and disadvantages to mode I 3 The pattern of spatial and main frequency groupings is similar to mode II 2 also see Advantages Most useful for line observations of objects that are in regions of extended emission Since the object is always being measured it is a more efficient mode than mode II 2 Disadvantages and Alternatives The scheme has similar disadvantages to the single point frequency switch mode see Section 4 2 1 3 System response will almost certainly be different at the requested and offset frequencies in a way which cannot be calculated from laboratory measurements This may lead to residual standi
102. he instrument f L Zero and comb integration I Integration on hot load I Integration on cold load initial position Integration on sky Figure 4 6 Timeline for the HIFI load chop observing mode 35 Observing with HIFI General Usage Sources with a high density of emission absorption lines that lie within extended emitting regions Like the Frequency Switch mode Load Chop is recommended to be used only with the sky reference option to obtain a spectrum at a User selected line free region within 2 degrees of the science target for standing wave correction in the pipeline This applies most strongly to Bands 3 4 6 and 7 and or in cases where lines may be too broad for interactive ripple fitting Advantages This is an efficient mode for measurements of sources in extended emission regions With OFF refer ence the mode can be used as a fall back for observations that would normally use a position switch but where the distance to the OFF position would require a slew time comparable to the total on source integration time With use of an OFF position in principle all pointed observations could be done with this robust mode at the expense of higher dead times Disadvantages and alternatives Generally inefficient with typically 1 3 to 1 4 of the total time spent on the actual science target time on the OFF position is less than that on the target However this is a mode which attempts to provide robust calibration of
103. here will be a slight penalty due to the slew time tax charged at each AOR and the temporary degradation of the achieved noise at the edges of the deconvolved spectra due to a coarser redundancy Once the LO purity has been satisfactorily established the excluded regions can be scanned if needed Presently this means that LO tunings only over the following ranges are advised Band 7a 1701 2 1755 and 1759 1793 8 GHz Note Several SDP and PSP1 AORs in Band 7a were carried out over these impure ranges prior to this information being available For observations in Band 7b requesting LO frequencies gt 1899 8 GHz there are currently no scheduling restrictions but Users must be aware of the lower performances that can result from the tuning issues described above For single frequencies in AORs using the Point and Map AOTs whenever possible the main lines of interest should be moved into the image bands if the new LO frequency falls in an area not affected by purity issues Otherwise it is probably wise to put the observations on hold until the chain is fixed in the targeted frequency area Note this will not have been possible for the very early SDP and PSP1 AORs which were scheduled before this information was available 58 HIFI Calibration 5 4 6 6 Spurious response in the HRS Spurs in WBS do not correspond to spurs in HRS While the investigation of HRS spurs has not yet been as detailed as in WBS it is already c
104. hest resolution available with the HRS high resolution spectrometer is not possible Frequencies to be observed NG Caa A UMNO SSIs ee In order to make observations at this frequency using the frequency switch mode the following steps should be taken to set up the AOR lt lt Target Name required SIMBAD gt i Orion Bar Background Fixed Moving Target Visibility Proper Motion Coord Sys Equatorial J2000 RA sh35ma2a oss J Use Proper Motion Dec Sdaam3e os PM RA aresec yean fo 000 Epoch 2000 00 PM Dec arcsec yean fo 000 Cancel Figure 6 18 Target name resolution for example 1 1e R n HSpot 2 Choose target Targets Menu gt New Target 2 1 Enter target name Orion Bar or user input coordinates 2 2 Resolve the name using SIMBAD option and fixed target tab 2 3 Once resolved acknowledge source coordinate by clicking OK The target name and coordinates are displayed at the top of the AOT screen see Figure 6 18 3 Selecting spectral lines for display during setup Frequency setting preliminary gt Prior to the setting up the observation it could be useful to import spectral lines of interest for display in the frequency editor The C line is already available to you within a stored set of default lines but some water lines for example may also be of interest On the Lines scroll menu choose either of the following JPL or CDMS lines to query and import l
105. iate from this value the deconvolution algorithm should model these as well and the same scaling should apply So far there are no indications of a departure away from 0 5 Analysis of the Spectral Scans taken during performance verification indicate that the deconvolved SSB root mean square RMS noise values are found to be in good agreement but also sometimes 1 5 to 2 times higher than the HSpot predictions in Bands 1 5 Very preliminary deconvolution results indicate that the HEB Bands 6 amp 7 suggest an even higher SSB RMS noise between 2 3 times more than currently predicted by HSpot Further work is ongoing and updates will be provided to users as results are obtained Observers should keep in mind that the production of good SSB spectra is highly dependent on the removal all artefacts standing waves spurs and the removal of all continuum baselines linear or non linear prior to performing the deconvolution reduction step Note When using the DBS reference mode of the spectral scan in bands 6 and 7 users should use the fast DBS mode rather than normal slow chop speed mode Mixer Stabilities Stability measurements have been made at several frequencies for each of the subbands in flight Results are now incorporated into the observing sequences produced by HSpot see Table 3 3 25 HIFI Scientific Capabilities and Performance Table 3 3 Allan stability times of the HIFI instrument measured for different noise resol
106. ided for the kinds of sophisticated analysis that is likely to be needed for HIFI data reduction These will avail able to the user through the Herschel Common Science System which will be made available by the Herschel Science Centre It should be noted that all pipeline software modules are available to users via installation of the Herschel Common Science System Reprocessing of data can therefore be per formed with pipeline or adapted pipeline scripts by users on their own workstations 1 2 Preparing HIFI for Operations In August 2009 a sequence of events triggered by a corruption of on board memory lead to the loss of the prime side electronics chain of HIFI Since then a significant effort has been made that has enabled a full recovery of the instrument using its redundant side electronics The special circumstances of HIFI s switch to redundant side operations and resuming with a com pressed Performance Verification phase and accelerated Observing Mode release has involved the support of many others together with the HIFI Calibration Scientists and Instrument Engineers This includes KP team apprentices who have been variously present at the HIFI ICC in the Fall of 2009 and during the performance verification phase starting end January 2010 and also the HIFI software development team who have been available at all times AOT test planning has been done in consul tation with the KP PIs coordinated by X Tielens Instrument P I F Hel
107. igh Resolution Spec trometers is connected to all 7 bands by a single input cable although a signal is only received from the active band 2 5 HIFI Spectrometers 2 5 1 The HIFI instrument provides an IF bandwidth of 4GHz in all bands except for band 6 and band 7 1408 1908GHz where only 2 4GHz bandwidth is available To sample this bandwidth HIFI has 4 spectrometers A Wide Band Spectrometer WBS and High Resolution Spectrometer HRS are available for each of the polarizations All spectrometers can be used in parallel although at fast data rates it is necessary to reduce how much is readout and stored since at the highest data rates the spectrometers provide data at a rate that is higher than the bandwidth available to HIFI on board the spacecraft The WBS is an Acousto Optical Spectrometer AOS able to cover the full IF range available 4GHz at a single resolution 1 1MHz The HRS is an Auto Correlator System ACS with several possible resolutions from 0 125 to 1 00MHz but with a variable bandwidth that can cover only portions of the available IF range The HRS can be split up to allow the sampling of more than one part of the available IF range In the following two subsections we describe the main workings of the two spectrometer types avail able to HIFI The Wide Band Spectrometer WBS The WBS is based on two vertical and horizontal polarization four channel Acousto Optical Spec trometers AOS see 8 and includes
108. in bands 4a and b 21 HIFI Scientific Capabilities and Performance 1500 1400 1300 1200 1100 1000 900 800 700 600 500 WBS H WBS V 1110 1130 1150 1170 1190 1210 1230 1250 1270 Figure 3 9 Double sideband system system temperatures of HIFI mixers in bands 5a and b 3000 2800 2600 2400 2200 il WBS H 2000 ri 1800 one 1600 RAN ae RON A LAN T moo na a A oh gee nal 1000 ca 1420 1470 1520 1570 1620 1670 Figure 3 10 Double sideband system system temperatures of HIFI mixers in bands 6a and b 3000 2500 2000 WBS H WBS V 1500 1000 500 1690 1740 1790 1840 1890 Figure 3 11 Double sideband system system temperatures of HIFI mixers in bands 7a and b Those with a marginally but still pumped mixer They show up as receiver temperatures of the order of 2 3 times the average temperatures These frequency areas are considered in the range offered in HSpot and will be scanned through during spectral scan measurements usually with an integration time doubled compared with other frequencies e Those where the mixer cannot be pump at all Such ranges at band edges have been cut off from the HSpot front end frequency ranges so that no time is spent observing at those frequencies When those holes occur in the middle of a band they are still offered to the User and will be scanned through during sp
109. ines targeted plus bonus lines are within both side bands If not move the frequency sliders in order to do so Avoid locating lines in the middle of the WBS sub band see Figure 6 30 gt in the present case all lines of interest are in the USB Clavel Oz On the Frequencies window click Done Observing mode setting Click the set the point mode button Select Dual Beam Switch tab For observations in band6 we may want to select fast chop Clik OK Time Estimator settings Same as for setup A except the noise goal setting is 200mK instead of 50mK Observation Estimates Same as for setup A Add Comments Same as for setup A Yaten ity Same as for setup A x Frequency Editor Lower Sideband LO Frequency jirat Upper Sideband E ON 1710 0GHz 1711 0GHz 9 1712 0GHz 1713 0GHz 1714 0GHz 17150GHz 1716 0GHZ 1717 0GHz 1718 0GHz 1701 1711 1741 1731 1741 1751 1761 1771 1781 1731 ___Leeal Oscillator Frequency GH Redshift l Reset Redshift 0 000063 Reset all frequencies Frequency Selection Line Transition Observed GHz Rest GHz E o iF H20 fea Eis ID IV ia jnasss SSS Cancel Figure 6 30 Frequency editor setup for the second set of water lines 95 Using HSpot to Create HIFI Observations Once both AORs have been created we can look at each of them in terms of where the beams used appear on the
110. ines from those catalogues Manage Lines in order to import personal lines into the line list Two options here Import a user defined formatted line file clicking on the Import button Add specific lines clicking on the Add button 85 Using HSpot to Create HIFI Observations 4 Setup observations Observation Menu gt HIFI single point 4 1 Setup A Instrument setting mixer band scroll down menu choose 7b this covers the right frequency range the frequency range for each HIFI mixer band is displayed below the pulldown menu Radial velocity scroll down menu choose e g optical km s Redshift enter velocity of the Orion Bar gt 10 km s Frame choose in the present case LSR Local Standard of Rest Spectrometer Use pulldown menu to choose WBS and HRS E g Separate setup for each polarization of HRS sub band NO HRS MECS Erba Neminel cesolution Sn Hoth polarivacions see Figure 6 19 Frequency Setting Within the Mixer Band Chosen Click on the Set the observing Frequencies button gt the Frequencies window pops up SVC hie on the Add wc ution gt the Frequency Editor window pops up This is where we indicate the frequencies spectral lines we want to observe On the Frequency Selection table gt we will put the CII lines in the Upper Sideband USB This will require a local oscillator LO frequency of around 1898GHz To obtain the correct settings Go
111. inuum level measurements are needed e g for some absorption line studies then a separate calibration scheme is selectable by the user to provide a stable continuum Note that selection of continuum stability timing in this mode can significantly reduce the efficiency of the obser vation particularly at the highest frequencies in bands 6 and 7 A schematic timeline for Mode I 2 appears in Figure 4 4 Telescope Tuning of the instrument Zero and comb integration Integration on hot load I Ld I Integration on cold load I Integration on sky chop angle 1 I initial position Integration on sky chop angle 2 Figure 4 4 Timeline of the HIFI Dual Beam Switch observing mode General Usage Point sources or slight extended lt 3 in diameter objects that are not sitting within or near to extended emission at the requested frequency Particularly useful for moderately distant to very distant extragalactic objects The fast chop mode Mode I 2a is expected to be used where accurate continuum or broad line low spectral resolution measurements are required The initial results from comparing performances of the normal or slow chop DBS with FastDBS modes indicate that the latter generally perform better with respect to correction for electrical standing waves in bands 6 and 7 The recommendation at this time is to only use the FastDBS mode in the HEB bands bands 6 and 7 31 Observing with HIFI Advantages A
112. ion 5 4 6 the various HIFI LO chains have frequency ranges in which they cannot provide enough output power in order to sufficiently pump the mixers The receiver noise temperature is very high in these ranges Unlike the purity issues however there is little improvement to be expected on the short term so these areas must be considered as regions of low performance over the spectral coverage currently achievable by HIFI While the border between sensitive and non sensitive ranges is not abrupt and the noise degradation is often gradual the band edges are defined and set in HSpot to avoid frequencies where the mixers are not even marginally pumped Between the formal HSpot band limits Users are able to recognize LO frequencies which offer lower performances from the output of time estimation in HSpot at the requested LO frequency Point and Map AOTs the noise temperature is quoted in the Message win dow The effect of higher noise temperature is to increase the observing time at a fixed noise goal entered by the User or conversely to reduce the S N ratio at a fixed observing time goal It is always worthwhile for the User to attempt to find a setting which minimizes the noise where some flexibility is allowed in the IF placement of the spectral line s of interest Note that system temperatures have been measured to a granularity of 2 GHz and therefore only significant differences may be noticed when changing the LO frequency that switche
113. ion to make maximum use of the energy collected by the HIFI optical beam and e at least 10 calibration accuracy with a goal of 3 NOTES 1 The time needed to observe a weak spectral line scales inversely with the square of the receiver noise temperature 2 The bandwidth is only 2 4 GHz in Bands 6 and 7 due to a bandwidth limitation in the state of the art HEB mixers that are used at these high frequencies 3 For bands 5 6 and 7 the receiver temperatures are rather 10 20 times the quantum limit 3 3 General Instrument Description The HIFI instrument provides continuous frequency coverage over the range 480 1250 GHz 625 240 microns in five bands with approximately equal tuning range An additional pair of bands provide coverage of the frequency range 1410 1910 GHz 213 157 microns The instrument operates at only one local oscillator frequency at a time In all mixer bands two independent mixers receive both horizontal and vertical polarizations of the astronomical signal although in some cases reduced bandwidth or use of a single polarization is re quired to stay within the data rate available to the instrument The user has the choice of using only a single polarization if he she chooses The first 5 mixer bands use SIS superconductor insulator superconductor mixers bands 6 and 7 use Hot Electron Bolometers HEBs The instantaneous bandwidth of the instrument will be 4 GHz The frequency coverage of the instru m
114. iption Herschel Bes ee Telescope Herschel Cryostat Key Sub mm wave free space propagation Microwave coaxial Herschel cable Service DCidigital twisted Module pakek Figure 2 3 General HIFI component diagram The local oscillator beams are fed into the Focal Plane Unit through 7 windows in the Herschel cryostat Within the Focal Plane Unit the astronomical signal from the telescope is split into 7 beams Each of these signal beams is combined with its corresponding LO beam and then split into 2 linearly polarized beams that are focused into 2 mixer units Each mixer unit generates an intermediate frequency IF signal that is amplified prior to leaving the Focal Plane Unit The IF output signals from the Focal Plane Unit can be coupled into two IF spectrometers the Wide Band Spectrometer a four channel subband acousto optical spectrometer AOS that samples the 4 8 GHz band at 1 MHz resolution and the High Resolution Spectrometer a high speed digital auto correlator ACS that samples narrower portions of the IF band at resolutions up to 140 kHz Each of the spectrometers includes a warm control electronics unit These four control units are in turn commanded by a single Instrument Control Unit ICU which also interfaces with the satellite s command and control system 2 3 HIFI Focal Plane Unit The HIFI Focal Plane Sub System consists of three ha
115. is obtained by clicking the Observation Est button to bottom left of the pointed or mapping AOT window The software calculates the most efficient sequence of telescope instrument operations that most closely fits the goal set If the values are okay to you then click OK and DONE on the main AOT window to complete the request Figure 6 16 shows the expected return information for an observation A noise estimate for each sub band is given and a precise time estimate The time estimate is based on a sequence of ON target OFF reference measurements Note that the observatory overhead 180 seconds in most cases is added to the total time estimate Further messages about the observation created including the observation efficiency and time on observatory instrument calibration overheads can be obtained from the Show messages button see Figure 6 17 These messages are automatically stored in the AOR file with the request information when the AORs are stored to a file on disk 83 Using HSpot to Create HIFI Observations ra Hifi Observation Breakdown x Observing Mode Breakdown LOF 1 1134 0 0031 0 0033 0 0031 0 0033 Observatory Overhead 5 fiso Total Time fusca Show messages Cancel Figure 6 16 The time estimator returns information about the total time and noise at both the frequency resolutions chosen for the given observation I x Observing mode HIFI Single Point DBS slowChop exe
116. k of the V 61 HIFI Calibration profile was 1 275 times that of the H can be attributed to data quality that suffers from when the line is located at the band edge in a region of high system temperature low sensitivity In two other cases it was found that there was a greater scatter of individual datasets at Level 1 in the pipeline processed results about the mean in one polarisation V over the other possibly reflecting varying power output levels between H and V In certain cases this effect at Level 1 leads to an apparent shift in line centre in the V polarisation at Level 2 but this could be remedied by removing outlier scans from the Level 1 data before averaging Beyond these cases there remains a larger difference in H and V profiles than is expected from un certainties in sideband gain or beam efficiency correction In the spectrum Figure 5 7 of NML Tau the peak in H is 74 of that in the V polarisation 4 0 5 0 4 0 3 0 2 uluulonlunluuln TITPTTTTP TTT TTT TTT T 0 1 n 0 0 CES g 110845 1108 50 1108 55 1108 60 1108 65 1108 70 usbfrequency GHz H _ H scaled by 1 149 y Figure 5 7 Line profile of NML Tau at 1108 5 GHz H and V profiles in this observation differ by 26 at the peak rescaling so the peaks match show no difference in line shape After simply scaling the H polarisation up it is seen that there is no mismatch in profile shape Extended So
117. lear that the spur in band 1a for instance does not impact the HRS at all Because spurs are found generally in spectral surveys and since spectral surveys generally do not have HRS data a full catalog of HRS spurs has been slower to generate 5 4 6 7 Treating Spurs in Software Spurs are automatically flagged during pipeline processing and ignored in subsequent processing For moderate spurs this is generally sufficient Strong spurs however which corrupt entire subbands or spectra require an extra step of cleaning This is easy to do in software and we have had excellent success in cleaning up spectral scans for use by the deconvolution routine 5 5 The Spatial Response Calibration of HIFI The framework for the spatial response description of Herschel HIFI is given in 11 This document presents the terminology related to the topic and estimates the telescope efficiencies and observations needed to assess some of the spatial response parameters 5 5 1 Context The intensity calibration approach described in the previous section involving the measurement of the instrument bandpass on hot and cold internal loads this translates the backend counts to so called antenna temperatures T4 This temperature scale see e g 11 16 is antenna and instrument de pendent There are two principal methods to derive antenna independent temperatures either a very accurate system model is needed or observations of celestial calibrator
118. lexers are used for beam combining bands 3 4 6 and 7 At present line selection in HSpot automatically places spectral lines at a good position for sensitiv ity avoiding internal spectrometer boundaries e g between 2 CCDs of the WBS spectrometer and bandwidth either side of the chosen line Observations from both horizontal and vertical polarizations may be combined but system noise levels typically vary for each of the bands and a reduction in observation noise by combining polarizations is slightly less than square root of 2 Detailed plots of the system sensitivity changes across all the bands are available from the Her schel Science Centre website in the HIFI instrument calibration area of http herschel esac esa int AOTsReleaseStatus shtml HIFI Scientific Capabilities and Performance 1000 CTH JPL Baseline WBS V COP WBS H COP l a 2 T O UW ke oul lt O DSB Noise Temperature K 480 640 800 960 1120 1280 1440 1600 1760 Frequency GHz Figure 3 4 Double sideband system system temperatures of HIFI mixers bands 1 to 5 are SIS mixers bands 6 and 7 are HEB mixers as used in HSpot System temperatures are based on in flight measurements using the internal calibrators of HIFI together with the H and V polarizations of the WBS spectrometer The institutions that created the different mixer subbands are indicated 3 5 2 Tuning Ranges In addition to certain known impure frequencies see Sect
119. ly based on some knowledge of the target Isolated objects for which no extended emission can be observed with Dual Beam Switch DBS or Frequency Switch modes while point sources in areas of extended emission that could cause contamination could be observed using load chop or position switch modes frequency switch could also be used here Sources which are likely to have a high density of spectral lines in their spectra should likely not use the Frequency Switch mode 84 Using HSpot to Create HIFI Observations More information on the HIFI single point observing modes and their relative merits are given in Chapter 4 of this manual Two pointed observation examples are presented here The first provides an example for the setup for observing the CII line in a photodissociation region PDR The second example shows how may water lines can be measured simultaneously in only two frequency settings of HIFI 6 3 1 Example 1 Observing the CII line using Fre quency Switch in a photodissociation region In this example we intend to observe a position Observation of C in a photo dissociation region PDR in the Orion Bar using HIFI s Frequency Switch pointed observation mode in a PDR Both of HIFI s spectrometers are to be used and both polarizations making a total of 4 frames per readout Several resolutions are made possible with the HRS we will use an intermediate frequency resolution NOTE at the frequency of the C line the hig
120. ly do not show standing waves at Level 2 Exceptions are sometimes observed however and in these cases the User can remove the waves with the sine wave fitting task FitHifiFringe in HIPE Two cases are shown below 44 Observing with HIFI e In Band 4b the diplexer causes a 650 MHz ripple Figure 4 8 shows a sine wave fit red relative to a baseline green automatically determined with the FitHifiFringe routine e Strong continuum sources show the effect of ripples in the passband calibration The periods are typically in the 90 100 MHz range and the amplitudes are at most 2 relative to the continuum See Figure 4 9 below for a case where 92 and 98 MHz since waves are present Band 4B in DBS mode Boxcar smoothed data 650 MHz standing wave red baseline green Pol eh eke a bs eel ball abe ae ay aes ap ade T 0 15 0 10 ee on es E 0 05 pee prr rrr A jji ji H Mia Pi Wel sll Me hd Intensity K 0 05 H 0 10 ea ot VS ca E el pt 0 15 EET tera WR e es S ad a Ed 1100 5 1101 0 1101 5 1102 0 1102 5 1103 0 1103 5 LSB Freq GHz Figure 4 8 Standing wave residual at Level 2 in a DBS observation with the fitted sine wave red relative to a smoothed baseline green 5 0 Intensity K 4 0 l 679 0 679 2 679 4 679 6 679 8 680 0 LSB Freq GHz Figure 4 9 Strong continuum source with two standing wave components at
121. m noise at the RMS noise level e The V polarization is systematically stronger than the H but the line profiles are different suggesting that at least part of the difference is due to a pointing offset 70 HIFI Calibration e The RMS noise was much greater when the CO line was in the LSB high LO frequency and this was true for both polarizations A summary of these results is represented in Figure 5 19 Summary plot of line intensity peak variation for spectral scans each point represents the standard_deviation average of a minimum 8 lines seen at different IF positions DD a pt 2S a ee G E E E 400 500 600 700 800 900 1000 1100 1200 Line Frequency GHz F WBS V WBS H Figure 5 19 Peak intensity variation of spectral lines as measured at 8 or more positions in the IF from pedrformance verification Spectral Scans 5 7 Summary overall calibration of HIFI and error budget 5 7 1 5 7 2 Strategy summary The absolute intensity calibration is being derived from planetary observations most especially Mars via the measurement of the telescope efficiencies Once the efficiencies are known and assuming they do not change significantly with time internal loads can be used as the day to day stable reference for intensity calibration transfer function Differencing measurements for calibration sources are done both ON source source reference and on an OFF position off reference I
122. mance verification phase following the switch to redundant side electronics The levels of agreement or disagreement are important to characterize since con tributing factors may include any of telescope pointing angular separation of the H and V beams on the sky possible intrinsic polarization of the source at the line frequencies of interest and instrument calibrations different beam efficiencies or sideband gains or power level output from the spectrom eter back ends The internal calibrations can account for up to 6 8 disagreement between H and V profiles measured as integrated fluxes IF spectral repeatability of point sources show that H and V profiles are in good agreement across bands 1 2 4 and 5 to within 3 The effect of pointing offsets between the two polarisations on line profiles in the case that the emission is extended or has a strongly varying velocity structure is harder to quantify The difference in pointing for H and V polarizations are noted in Section 5 5 2 2 Compact Sources Line centres and line shapes are in excellent agreement between H and V profile among the AGB stars observed during PV 2 In many cases the V polarisation shows the stronger line but typically the peak values of the H profiles fall within 7 of the peak in V One exception to this is NML Tau which showed differences in the peaks of profiles of over 30 in some cases Some of the profile discrepancies e g obsid 1342190160 where the pea
123. ments will also apply to AORs requiring differing LO bands For instance it is currently not be possible to group or concatenate different instruments or in HIFI s case different LO bands together under most circumstances Source integration times will be optimised according to the user s observing time goal or noise level goal Providing user input is discussed in Chapter 6 where specific examples for setting up HIFI observations are given using the HSpot tool 4 2 The HIFI Observing Modes Observations created in one of the three AOTs will be performed in a number of different Observing Modes which differ mainly in the selection of the reference measurements during the course of ob serving All observations consist of source measurements reference measurements and a set of cali bration measurements that will be used to fully calibrate the spectra in both frequency and intensity Observing mode design is intended to supply an optimum balance between observing efficiency and self contained calibrations timed by instrumental performance and stability metrics The currently de signed Observing Modes and their relation to the AOTs is given in the following chart Figure 4 1 27 Observing with HIFI 4 2 1 4 2 1 1 Reference AOTI AOT II Mode Single point observations Mapping observations AOT III Spectral scan observations Position Observing mode I l Observing mode II 1 switch Fixed point position switch O
124. mich Project Manager P Roelfsema and with the Mission Scientist J Cernicharo These persons should be acknowledged as having directly supported the flight qualification of HIFI as a science instrument AOT Uplink Engineering Team P Morris Caltech M Olberg SRON Chalmers V Ossenkopf U K ln C Risacher SRON D Teyssier HSC ESA Instrument Engineers and System Architects P Dieleman SRON K Edwards SRON W Jelle ma SRON A de Jonge SRON W Laauwen SRON J Pearson JPL The HIFI Instrument Observer s Manual HIFI Calibration Scientists I Avruch Kapteyn SRON A Boogert Caltech C Borys Caltech J Braine U Bordeaux F Herpin U Bordeaux R Higgins U Maynooth S Lord Caltech A Marston HSC ESA C McCoey U Waterloo R Moreno Obs Paris M Rengel MPS HIFI Software Development Team R Assendorp SRON B Delforge SRON A Hoac Cal tech D Kester SRON A Lorenzani Obs Acetri M Melchior U Appl Sci NW Switzerland W Salomons SRON B Thomas SRON E Sanchez CSIC R Shipman SRON Y Poelman SRON J Xie Caltech P Zaal SRON HIFI KP student postdoc visitors E DeBeck U Leuven T Bell Caltech N Crockett U Michi gan P Bjerkeli Chalmers P Hily Blant Obs Grenoble M Kama U Amsterdam T Kaminski CAMK B Larsson Obs Stockholm B Lefloch Obs Grenoble R Lombaert U Leuven M de Luca Obs Paris Z Makai U
125. n Cancel Figure 6 34 Final mapping mode setup for example 3 The following procedure allows you to visualise how and where this map will be oriented on the sky for a given observing date 4 Visualise planned observations 4 1 Select the M51 AOR in the main Observations window 4 2 On the Image scroll menu select the image of interest e g the optical Digital Sky Survey DSS gt a plate of M51 appears 4 3 On the Overlays scroll menu select AORs on current image 4 4 Click on Current AOR gt the target visibility table pops up 4 5 Choose a date then click OK In the present case Gags AOIL Meg 7 OTRo gt the map coverage and the OFF position appear overlaid on the DSS plate see Figure 6 35 99 Using HSpot to Create HIFI Observations REE ixi Hivtap 0000 F xie art F x sal z Figure 6 35 Overlay of example 3 on DSS image The scan mapping is shown as a set of scan lines that are overlapping as should be the case for Nyquist map sampling The OFF position is shown as a single circle to the left 6 5 Example Setup of a HIFI Spectral Scan Observation 6 5 1 One of the most impressive capabilities of HIFI is its ability to cover a large range of frequency A spectral scan mode of observing has been developed to take advantage of this In this mode the local oscillator frequency is stepped through a range of frequencies A single request providing a ra
126. n Optics Assembly Diplexer Beamsplitter 7 channels Cold LO Optics 7 channels Telescope Beam Calibration Source Assembly Second Stage IF Amplifier Box Vertical Mixer Sub Assembly 7 channels Horizontal Mixer Sub Assembly 7 Channels Local Oscillator Beams 7 Figure 2 5 Back side of the HIFI FPU 2 3 1 The Common Optics Assembly The Common Optics Assembly forms the basis of the FPU structure and mounts directly on the Herschel optical bench HIFI Instrument Description 2 3 2 Figure 2 6 HIFI telescope relay optics Figure 2 7 The channel splitting optics as seen from the side with respect to Figure 2 6 The optics assembly relay the instrument s 7 signal beams from the telescope s focal plane into a diplexer box This is done with 6 common mirrors the telescope relay optics see Figure 2 6 and 7 sets of 3 mirrors the channel splitting optics see Figure 2 7 Together these optics have three primary functions e They produce an image of the telescope secondary on the fourth mirror in the chain after the sec ondary M6 enabling the implementation of a Focal Plane Chopper e They produce an image of the telescope focal plane on the first mirrors in the Channel Splitting Optics allowing the beams to be split by seven mirrors with different orientations e Inea
127. n The Fly scan map Dual beam Observing mode 1 2 Observing mode II 2 X Observing mode III 2 itch oe Point w Beam Switch DBS raster cross DBS spectral scan ee Observing mode 3 Observing mode IL 3 Observing mode IIL 3 Point wiFrequency Switch OTF wiFrequency Switch Frequency switch scan Load Observing mode I 4 Observing mode II 4 Observing mode III 4 cho P Point w Load Chop OTF w Load Chop Scan with load chop Figure 4 1 Overview of available AOT observing modes The numbering scheme of the observing modes represents an association between the AOT class in Roman numerals and four possible modes of reference treatment Arabic numerals that are foreseen The dual beam switch modes further split into two separate modes using a slow chopper speed Mode I 2 and a fast chopper speed Mode I 2a Each Observing Mode uses a somewhat different scheme for the data processing including the inten sity and frequency calibration depending on how the reference measurements are obtained while ob serving Thus the noise level and the drift contribution to the total data uncertainty of the calibrated data obtained from one of the AOTs depend critically on the Observing Mode i e on the reference measurement scheme To enable an educated selection of the AOT Observing Modes the following subsections provide descriptions of the scientific motives typical usage user options data output advantages and disad vantages Modes of the Single Point AOT
128. n in principle approach an observing time efficiency of 100 per cent The system instability is taken into account here by the repeated observation of an OFF position which is either free of emission or has a well known emission profile The mode is relatively insensitive to standing wave problems because only one optical path is used While the telescope scans any particular row of the map permanent data readouts are made at regular time intervals The time intervals are set such that the telescope scan covers the width of a single point in the output map default is Nyquist sampling distance The source integration is performed during the whole scan except for very small breaks for the data readout After each row the telescope motion changes its orientation so that the next row will be scanned in the opposite direction The integration of instrument data is stopped during these turns taking serendipity data might be possible but this should not interfere with the optimum start and stop times for the integration within each row After a period determined by the system stability time the scanning of the map is interrupted for the reference measurement on the OFF position Reference measurements are only taken after an integral number of scan legs Changes in the instrumental sensitivity are measured in the frame of a fourth loop using the known difference in the radiation field between hot and the cold internal loads This load calibration is
129. n regions of extended sub mm emission 33 Observing with HIFI Disadvantages and alternatives System response differs between requested and offset frequencies The differences in flight verify that the scheme for observing a sky OFF position at the same frequencies to compensate for residual standing waves in the ON target difference measurements is a very strong recommendation It should not be used for sources with rich spectra or very broad lines which would make it impossible to deconvolve the contribution of both phases from the difference spectrum preventing any reliable data reduction If these conditions cannot be met and no emission free region is nearby or timing constraints in the logic for this Observing Mode are too difficult then the load chop mode with OFF calibration Mode I 4 is expected to be a better option User inputs Target ON position optional reference OFF position LO band and frequency frequency throw see Table 4 1 minimum and maximum goal frequency resolution of the calibrated data spectrometer usage and total observing time or noise limit at the lowest goal resolution Table 4 1 Frequency throw values available by HIFI subband Frequency throws have been optimised during early in flight testing in each subband Band Large nega Small nega Small posi Large posi tive MHz tive MHz tive MHz tive MHz la 288 94 94 288 1b 288
130. nal offset Chapter 3 HIFI Scientific Capabilities and Performance The HIFI instrument has been designed to provide very high spectral resolution across a large range of far infrared and sub millimetre wavelengths A large fraction of the frequency range covered by the instrument can not be observed from the ground In this chapter we discuss the range of science capabilities of the instrument 3 1 What Science Is Possible With HIFI HIFI s very high spectral resolution coupled with its ability to observe thousands of molecular atomic and ionic lines at sub millimeter wavelengths make it the instrument of choice to address many of the key questions in modern astrophysics related to the cyclic interaction of stars and the interstellar medium A wide range of chemical and dynamical studies are possible using HIFI However the original set of science objectives for the instrument are given in the following section 3 1 1 HIFI s Scientific Objectives At the outset of the mission the major scientific objectives of the HIFI instrument are e to probe the physics kinematics and energetics of star forming regions through their cooling lines including H20 see Figure 3 1 to survey the molecular inventory of the wide variety of regions that participate in the life cycle of stars and planets to search for low lying transitions of complex species i e PAHs and thus study the origin and evolution of the molecular universe e t
131. ne position on the sky e AOT II Mapping for covering extended regions e AOT III Spectral Scanning for surveying a single position on the sky over a continuous range of frequencies selected within the same LO band by the user Each AOT can be used in a variety of different modes of operation providing the widest range of options for performing spectroscopic science observations in different astronomical that HIFI and the Observatory will allow in terms of reference measurements and calibration In other words the three AOTs come with Observing Modes where the user may select from different calibration modes choosing the mode best suited to the observing situation and science goals The Observing Modes are available to the user through the HSpot observation planning tool available in the Herschel Proposal Handling System The Observing Modes are described in the following sections with typical usage examples and limi tations and steps for creating Astronomical Observing Requests AORs in HSpot which represent real observations Regardless of mode however users of HIFI should be aware of the following general condition e Only one LO band is planned to be operated at any one time meaning that observations requiring frequencies in different LO bands will always require separate AORs AORs making use of the same LO band can be scheduled together e g via chaining but the same scheduling restrictions that apply to different instru
132. ng against internal loads also takes place The mode works for each scan map position in the same way as for the point source load chop mode see Mode I 4 40 Observing with HIFI Advantages It is a good mode for situations where fast chopping references are needed as may be the case for band 6 and 7 measurements and for when frequency switching is made difficult by the density of spectral lines or the expected existence of broad lines It is an efficient mode for mapping of extended line emission regions since telescope slews to an OFF position are not necessary and the target grid positions are always being measured at slightly offset frequencies Particularly useful for mapping large regions of line emission where a DBS measurement see Mode I 2 would have contaminating emission in the reference beams Disadvantages and Alternatives The scheme has similar disadvantages to the single point load chop mode see Section 4 2 1 3 The changing light path between observing loads as opposed to the sky can lead to residual standing waves User inputs The user has the possibilities of rectangular map sizes scan length X and cross scan map size Y The cross step can be set at Nyquist sampling or one of a number of set cross step sizes in arc seconds Data calibration 4 2 3 4 2 3 1 Each OTF map position can be calibrated in the same way as single point load chop data see Sec tion 4 2 1 4 Modes of the Spec
133. ng waves Continuum measurements can not be made with this mode without an OFF position measurement to calibrate the baseline Mode III 2 is preferable for measurements where the baseline continuum is needed to be accurately measured User inputs The user has choice of frequency range within the mixer band frequency range chosen partial or full band The user can choose a redundancy of between 2 and 12 Higher values increase the fidelity of the final single sideband spectrum expected from the data reduction of the mode but also make the mode less efficient The frequency throw is also an input choice for the user Data calibration Data reduction consists of two parts the calibration of the double sideband spectrum see Sec tion 4 2 1 3 and the deconvolution of the set of double sideband spectra into a single sideband spec trum The calibration of the frequency switch spectra is identical to the calibration in the single point with frequency switch see Section 4 2 1 3 The load measurements for the bandpass calibration are taken at exactly the same LO frequencies as the data Sideband deconvolution is provided via a data software task within the HIPE software environment and must be run interactively by the user after each double sideband spectrum has been processed More information on the sideband deconvolution software is noted in Chapter 6 4 2 3 3 Mode Ill 4 Spectral Scan with Load Chop Purpose Used to observe a point sour
134. nge of frequencies is made by the user and the detailed settings are calculated by the software In this setup only the Wide Band Spectrometer data is guaranteed to be obtained The HRS may run in a parallel serendipitous mode if the data rate limit is not exceeded This mode has been developed in association with a deconvolution algorithm see Chapter 7 which is able to take the double sideband data that HIFI obtains and produce a single sideband spectrum see Chapter 2 regarding single and double sideband data and HIFI There are three modes for doing spectral scans A Dual Beam Switch DBS Frequency Switch or Load Chop referencing mode may be used For small sources less than 3 arc minutes across the DBS mode can be used Frequency switch and load chop modes can be used for sources inside extended emission Load chop is preferred for complex line sources In the following example a hot core is to be surveyed using the spectral scan mode The step by step setup is illustrated Example 4 Spectral Survey of a Hot Core In this example we use the spectral scan AOT that allows wide frequency coverage on a single target In this case our target is a hot core IRAS16293 2422 Our spectral scan is to cover the frequency range 488 to 620 GHz These frequencies are covered by mixer bands la and 1b of HIFI In order to do this observation we will need to make two observing requests one for band 1a and one for band 1b Frequency setups consider
135. ns see Chapter 2 These resolu tions are available for any of the setups where the HRS is chosen in pointed or mapping observations The user has the choices given in Chapter 3 see Table 3 2 Each of the two HRS spectrometers can be set at the choice of the user see Figure 6 5 to different resolutions NOTE that the highest possible resolution setting of the HRS is higher than is possible from the system as a whole for band 3a and higher frequency bands Separate setup for each polarisation of HRS sub bands No we The HRS Mode for H or both polarisations Nominal Resolution HRS Resolution MHz for H or both polarisations 0 250 j The HRS Mode for w polarisations HRS Resolution MHz For w polarisation 0 250 Figure 6 5 HIFI HRS resolution choice Saving and loading of instrument and frequency settings see following section for frequency settings can be achieved using the Save instrument settings and Load instrument settings buttons These allow the settings to be stored to a file on a local disk The settings can then be used for other targets other HIFI AOTs or with AORs in another program 6 2 1 2 Selecting the Frequency Settings for Pointed and Map ping Observations Within the chosen mixer band frequency range we need to provide the local oscillator LO setup that allows the observation of user selected frequency regions To choose these regions the user clicks on the Frequency Settings button This loa
136. ns with detector readings as fluxes versus wavelength Telescope pointings are given in RA and DEC the conversion from satellite pointing data to RA and DEC is provided by ESA It should be noted that the user can run all the HIFI data pipelines interactively or in batch mode from his her own local computer system using the HCSS This means that data reprocessing can be done by the astronomer rather than needing to be requested from the Herschel Science Centre 7 2 Additional Observatory Meta Data Aside from the raw telemetry any HIFI data product will contain appropriate meta data describing the raw data and adding information not contained in the data themselves The data descriptive meta data will describe e g the number of pixels in a spectrum units along axes etc Additional information will be items like instrument set up used integration time observed source processing steps applied to the data Any set of HIFI data in the database is linked to other information on the observed object the observer the program etc This information is not stored in the HIFI data proper but can be found by navigating the Observation Context which the standard repository for a complete set of data associaated with an observation When exporting HIFI data to e g FITS some relevant information from these associa tions is also copied into the FITS file 7 3 Example HIFI data products 7 3 1 Level 0 products The HIFI level 0 data frame products con
137. o Create HIFI Observations Ki Observing Mode Settings eS Observing Mode Settings Choose one of the modes below No mode selected l Position Switch Dual Beam Switch Load Chop Frequency Switch Throw Ee Throw Small Positive x Reference Position Specifications Ret Type By offset By position v s RA offset aremins 13 00 Dec offset arcmins fo o0 RA degrees fe 0000 late degrees Jo 0000 x Choose Position Cancel Figure 6 23 Selection of frequency switch with offset Time Estimator Settings Time Estimator Settings Estimate Type Time z Resolution units MHz z J One GHz Reference LOF Res Min width O Res Max width Time Nowe Goal a S A a Cancel Figure 6 24 Setup of time estimate for the example observation KJ Herschel Observation Planning Tool GT2 Call Phase 1 version E File Edit Targets Observation Tools Calibration Images Lines Overlays Options Window Help Figure 6 25 Appearance of the final AOR on the Observations screen After having completed an AOR we may wish to see how the observation is projected on the sky and whether any contamination may be associated any of the measurements In order to do this the projected positions of the instrument bands can be displayed as overlays on images taken at other wavelengths 90 Using HSpot to Create HIFI Observations An example for
138. o determine the out gassing rate of comets through measurements of H20 and to study the distri bution of H20 in the giant planets e to measure the mass loss history of stars which regulates stellar evolution after the main sequence and dominates the gas and dust mass balance of the Interstellar Medium ISM see Figure 3 2 e to measure the pressure of the interstellar gas throughout the Milky Way and resolve the problem of the origin of the intense Galactic CH 158 micron emission measured by COBE todetermine the distribution of the C C and N N ratios in the Milky Way and other galaxies to constrain the parameters of the Big Bang and explore the nuclear processes that enrich the ISM and e to measure the far infrared line spectra of nearby galaxies as templates for distant possibly primor dial galaxies HIFI Scientific Capabilities and Performance ortho H 0 557 GHz Hydrogen Sulphide Methanol Formyl Cation Methanol Sulphur Dioxide Hydrogen Gyanide n a Mhan f HIFI Spectrum of Water and ESA HEXOS and the HIFI consortium Organics in the Orion Nebula E Bergin Figure 3 2 Early Science Demonstration Phase HIFI spectral scan towards the Orion nebula region Mul tiple LO settings were used to obtain a complete spectrum across the available frequency range of the whole of a HIFI subband The combined dual sideband spectra were deconvolved to provide the single sideband spectrum shown
139. odules starting from raw HIFI data frames obtained from either polarization using a HRS Note that the data frames from the HRS are correlation functions e 1 Re organize data into subbands depending on the configuration Output is the autocorrelation functions re organized in subbands e 2 Compute power and offset of the subband values e 3 Remove bad channels e 4 Normalize the raw correlation function Normalizes by channel 0 so that the power is set to 1 Output is a normalized autocorrelation function e 5 Apply a quantization distortion correction Uses a calibration table to correct for the analogue to digital quantization effects Output is a corrected autocorrelation function e 6 Apply power correction The signal power is corrected for non linearity effects e 7 Apply window default Hanning smooth used e 8 Apply symmetrization to the autocorrelation functions e 9 Apply FFT to place spectrum in frequency domain e 10 Apply frequency scaling based on the HRS LO frequencies values to place appropriate frequency information in the frame placement within 4GHz IF frequency range 11 Multiply the normalized spectrum power 1 by the corrected power computed in 6 e 12 Apply hot cold flux calibration e 13 Subtract reference spectra e 14 Apply sideband gain correction based on ground based test information e 15 Apply antenna temperature efficiency 7 5 Deconvolution Processing of Spectral Scan Data To summa
140. olds in all cases where the scientific aim of the observation does not require an accurate treatment of baseline effects ignoring standing wave ripples or other baseline distortions This will be the case for observations of very narrow lines where even a distorted baseline can be approximated by a simple linear profile across the line In such cases OTF maps with frequency switch can be more efficient but not good for broader lines where the load chop version of OTF is better It will not be possible to determine the continuum level from OTF maps If continuum mapping for a small region is required then the DBS raster map should be used User inputs The user has the possibilities of rectangular map sizes scan length X and cross scan map size Y The cross step can be set at Nyquist sampling or one of a number of set cross step sizes in arc seconds The user is also asked for the position of an OFF reference source which is mandatory Data calibration The reference for each scan map point is based on a combination of prior and following OFF position measurements Because of instrumental limitations with respect to data rates the speed of the tele scope motion and the gain instabilities it will not be possible to obtain an accurate determination of the continuum level from observations in OTF maps with position switch reference The subtraction of a zeroth order baseline should always be expected although the baseline itself does no
141. ology pp 339 348 26 28 March 2002 Harvard University Cambridge Massachusetts USA 2 Jackson B D de Lange G Zijlstra T Kroug M Kooi J W Stern J A and Klapwijk T M Low noise 0 8 0 96 and 0 96 1 12 THz superconductor insulator superconductor mixers for the Herschel Space Observatory 2006 IEEE Trans on Microwave Theory and Techniques vol 54 no 2 pp 547 558 3 Jackson B D de Lange G Zijlstra T Kroug M Kooi J W Stern J A and Klapwijk T M Niobium titanium nitride based superconductor insulator superconductor mixers for low noise terahertz receivers 2005 Journal of Applied Physics vol 97 no 11 pp 113904 113912 4 Delorme Y Salez M Lecomt B Peron I Dauplay F Feret A Spatazza J Krieg J M and Schuster K Spacequalified SIS mixers for Herschel Space Observatory 222s HIFI band linstrument 2005 16th Int Symp on Space THz Technology Goteborg Sweden May 2 4 2005 5 Salez M Delorme Y Peron I Lecomte B Dauplay F A 30 bandwidth tunerless SIS mixer of quantum limited sensitivity for Herschel HIFI band 1 2002 SPIE Proc Vol 4855 2002 02 6 Cherednichenko S Kroug M Khosropanah P Adam A Merkel H Kollberg E Loudkov D Voronov B Gol tsman G Huebers H W and Richter H 1 6 THz HEB mixer for far infrared space telescope Hershel 2002 Physica C vol 372 pp 427 431 7 Cherednichenko S Drakinskiy V
142. on in the same way as for the point source frequency switch mode see Mode I 3 Advantages It is a good mode for situations where fast chopping references are needed as may be the case for band 6 and 7 measurements An efficient mode for mapping of extended line emission regions since telescope slews to an OFF position are not necessary and the target grid positions are always being measured at slightly offset frequencies Particularly useful for mapping large regions of line emission where a DBS measurement see Mode II 2 would have contaminating emission in the reference beams Disadvantages and Alternatives The scheme has similar disadvantages to the single point frequency switch mode see Section 4 2 1 3 System response will almost certainly be different at the requested and offset frequencies in a way which cannot be calculated from laboratory measurements This may lead to residual standing waves User inputs The user has the possibilities of rectangular map sizes scan length X and cross scan map size Y The cross step can be set at Nyquist sampling or one of a number of set cross step sizes in arc seconds The frequency throw is selectable by the user Data calibration Each OTF map position can be calibrated in the same way as single point frequency switch data see Section 4 2 1 3 4 2 2 5 Mode Il 4 OTF Maps with Load Chop Description In this mode a scan map is made across a source during which choppi
143. ong the way a number of the features of the HSpot observation planning software will be illustrated 6 2 HSpot Components for Setting Up a HIFI Observation 6 2 1 Working with A HIFI Pointed or Mapping Obser vation Template In order to set up an observing request in HSpot we start by working with an AOT Astronomical Observing Template Such a template leads you through the possible choices for setting up HIFI so that the final request an Astronomical Observing Request AOR contains all the necessary infor mation for the correct frequencies to be measured on the sky by each of the spectrometers and their subbands that are being used There are three types of AOTs e HIFI Pointed Observation e HIFI Mapping Observation e HIFI Spectral Scan The HIFI Pointed and Mapping Observation setups have several similarities except for the observing mode choices while the spectral scan mode is a special mode that allows for large frequency range coverage within a single observation To choose one of the three AOTs go to the Observation pulldown menu at the top of the main screen that appears when HSpot is started up see Figure 6 1 73 Using HSpot to Create HIFI Observations Herschel Planning Tool File Edit Targets 2B E Observations Carica Tools Images Lines Overlays Options Window Help HIFI Single Point HIFI Mapping PACS Photometer u PACS Line Spectroscopy ical Observation Requests AORs B
144. or 1 0 1 0 2 4 higher Beam Efficiencies value in bands 2 4 4 5 and 7 0 6 5 from Pointing band la to 0 6 5 band 7b 72 Chapter 6 Using HSpot to Create HIFI Observations 6 1 Overview Within HSpot we have four modes of taking point sources Dual Beam Switch DBS with fast or slow chop load chop with or without a reference OFF position frequency switch with or without a reference OFF position and position switch three modes of mapping On the fly or scan mapping with an OFF or frequency switch reference and raster mapping using DBS Under mapping modes there is also the possibility of a fixed position 5 point cross designed to handle small pointing or position inaccuracies to provide accurate flux measuremetns There is also a special mode for allowing large spectral coverage in a single observation the spectral scan mode which can use either a dual beam switch or frequency switch reference scheme It is also possible to set up the HIFI spectrometers so that multiple resolutions are available covering several spectral lines in a single observation In this chapter we provide examples of how to set up some simple and not so simple observations that cover point sources mapping and spectral scans The intent of this chapter is to illustrate the general way in which to formulate HIFI AORs that are suitable for submission to the Herschel Science Centre HSC as part of a proposal Al
145. or 1342190184 It is inter esting to note that the V profile from the OFF position corresponds exactly with the H profile from the ON position 1342192229 a T ee i S amp B Ho q f fl 5330 5335 5340 5345 5350 5355 5360 frequency MHz HOn Hort VOn vor Figure 5 12 As for Figure 5 11 but for obsid 1342192229 The same behaviour is seen but the overall spread in profiles is smaller than for 184 One possible reason for this behaviour could be that there is some scatter in where HIFI points for each integration due to shifts after telescope slews between the ON and OFF positions and as HIFI chops between source and reference Investigations indicate the pointings for each integration on source for 184 have a spread of approx 2 and is very similar for 229 This is of the level of the pointing accuracy of the telescope This scatter in pointing and perhaps in combination with velocity structures arising in shocked re gions in outflows could give rise to the difference in profiles seen between the ON and OFF positions 64 HIFI Calibration In support of this theory the fractional difference in intensity relative to the mean intensity of each integration for each polarisation are plotted in Figure 5 13 and Figure 5 14 for the OFF and ON po sitions respectively A line profile is plotted in each case to show variation with position in the line If variations between indi
146. ossible to adjust the chopper speed via user inputs When setting time estimates the chopper and dual beam cycling speed is affected by the associated Allan time For higher cycling use larger goal resolutions for which the Allan times are larger This forces faster repetitions of the cycle HSpot messages available following time estimation indicate the achieved speed Data Calibration For the standard data reduction of dual beam switch observations the double difference has to be computed between the counts in the two chop phases at one telescope position and the corresponding difference for the second position As two of the phases contain signal from the source the total radiometric signal to noise ratio of the calibrated data corresponds exactly to the value from one phase The mode thus has a maximum efficiency of 0 25 in the case of no dead times The double difference completely cancels out all standing wave contributions from the receiver noise and from warm telescope components promising a perfect calibration of the underlying continuum or a perfect zero level baseline in case of sources with no continuum contribution It also guarantees a cancellation of all intensity drift effects that are purely linear within the corresponding cycle time An estimate of the total drift noise contribution can be obtained from the stability parameters of the instrument measured in terms of an Allan variance spectrum When all ON OFF cycles are performed
147. our current observation is to overlay the projected beam positions on MSX Mid course Space Experiment a mid infrared imaging mission 4 Visualise planned observations 4 1 Select the AOR of interest in the main Observations window by clicking on the line in which it is contained this makes it the current AOR 4 2 From the Image scroll menu select the image of interest e g MSX gt a plate of Orion Bar appears default is band A of MSX which is data taken at 8 microns wavelength 4 3 On the Overlays scroll menu select AORs on current image A Aw lnickonm Glace nie AOR gt the target visibility table pops up 4 5 Choose a date when the target is visible then click OK n the present case e g 2011 Sep 10 00 00 00 Depending on date such things as chopper beam switch positions will change gt the point and the OFF position appear overlaid on the MSX plate as blue circles see Figure 6 26 Ka Herschel Observation Planning Tool Phase 1 loj x File Edit Targets Observation Tools Calibration Images Lines Overlays Options Window Help altel S Zils9 D 386 e I T i SSeS eee SSS Mouse Control Mouse Any Shift Eejt Button Centre the Image at point a S e C ae A Observations MSX A Orion Bar Target Orion Bar Type Fixed Single Total Duration hrs 0 2 T Figure 6 26 Observation overlaid on Band A MSX image 8 microns
148. owing conclusions are reached for the bands without diplexers e Band 2a the integrated line intensities vary by less than 1 around the average value e Band Sa there is a slight USB LSB line strength difference 3 This is true for both polarizations The H V H intensity difference is also 3 on average true for both sidebands This could be due to pointing offsets between the polarizations e Band 1b similar to Band 2a For Band 4a the only diplexer band tested so far the sideband ratio test was carried out without retuning the diplexer and then the same test was redone but with retuning The following conclusions are reached e The observations without diplexer retuning show that in the unlikely event of a diplexer mistune the diplexer window significantly affects calibration At least some of this variation can be eliminated by recalibrating with the ratio of the noise levels at the frequency for which the diplexer is correctly tuned This should not happen for normal observing e The Standing Wave test showed no convincing effect the variation is less than 2 and this slight variation does not show a 650MHz period like the diplexer standing wave e With the diplexer retune and only taking into account the scans preceding the sharp increase in noise level the CO 9 8 line seen in the LSB is a few SBR effect or rather due to the diplexer All of the variations seen are greater than identical spectra affected only by rando
149. parison of H and V profiles in compact sources show that the line profiles agree to within 7 which is within current calibration uncertainties An exception to this is NML Tau which shows deviations of up to 30 Some of these discrepancies were found to be due to issues with the data such as poor line placement or scatter in data at Level 1 It is harder to disentangle the effects of extended emission and pointing offsets between the H and V beams e Artificial polarisation effects can be created due to the H and V beam offset and can be particularly affected in if there is a strong velocity structure associated with the observation e In the case that polarisation differences are of importance care should be taken to avoid chopping into emission When investigating differences in H and V profiles it is helpful to go back to Level 1 data Polarization Science To date only two linear polarization scientific studies have been carried out on Herschel The first of these dealt with a star representing a spatially unresolved source The other involved an extended 65 HIFI Calibration source Both were carried out in band 1b although similar results are expected in other bands The main factor to keep in mind is that the H and V receivers on Herschel are not precisely aligned The extent of this misalignment differs from band to band but tends to be of the order of a few seconds of arc The misalignment values are known for each
150. ple 1 E Frequency Editor Lower Sideband Lo Frequency i7355 Upper Sideband IF x60 IF 360 Siicnemienn a a a EHDA NNO can hina in OA aN a Moon TerAE TORY eat 1894 0GHz 1895 0GHz 1896 0GHz 1897 0GHz 1898 0GHz 1899 0GHz 1900 0GHz 1901 0GHz 1902 0 1793 1803 1813 1823 1833 1843 1853 1863 1873 1883 1893 IL Local Oscillator Frequency GH2 Redshift Reset Redshift 0 00009 Reset all frequencies Frequency Selection zl Line Transition Z Observed GHz Rest GHz wes iic zlc zI Jv 1300 359 1800 537 HRS 1 Z No Lines Z No Lines z v JHRS 2 ie Lines No Lines zi Vv aT Cancel Figure 6 20 Spectral line selection for Example 1 Clicking on the dark red line above the zoomed fre quency scale shows that this is the position of the CS 39 38 line The bright red line is at the position of the CII line 88 Using HSpot to Create HIFI Observations x Frequency Editor Lower Sideband LO Frequency fizs7ass Upper Sideband RS 1 IF 3 60 RS 2 IF 3 60 BS ON aagana Hao 331 904 vp 1893 686513 ys yess sss rt pe trees ayaan NANANA pee tee eee A EANAN raga 7894 0GHz 1895 0GHz 1896 0GHz 1897 0GHz 1898 0GHz 1899 0GHz 1900 0GHz 1901 0GHz 1902 00 1733 1803 1813 1823 1833 1843 1853 1863 1873 1883 1893 Local Oscillator Frequency GH2 Redshift Reset Redshift 0 000094 Reset all frequ
151. polarisations po The HRS Mode for V polarisations Nomina Resolution z HRS Resolution MHz for V polarisation 1 000 Figure 6 32 Instrument settings prepared for example 3 98 Using HSpot to Create HIFI Observations IE x Frequency Editor C Lower Sideband LO Frequency jama Upper Sideband Local Ossilator Frequency GHA 4 J Redshift _ Ree Recan pE _ Reset all frequencies Frequency Selection J E ii Transition U Observed GHz F co M i Mises posesa Rest GHz Warning messages P a Cancel Figure 6 33 Frequency editor setup for the M51 example The slider has been used to adjust the LO setting and allow the CI 2 1 to be within the lower sideband of the observations along with the CO 7 6 line light and dark green lines on the frequency scale at upper left Observing Mode Settings Select a mapping mode OTF mapping wiload chop OTF mapping wi Frequency Switch DBS Cross Map No mode selected On The Fly mapping DBS Raster Mapping On The Fly mapping X are minutes Bo Y are minutes Bo Position Angle joo Nyquist sampling On Distance between scans arcseconds pie oo z Reference Position Specifications Ref Type By offset By position iu vex RA offset aremins gt 10 00 C No Dec offset aremins p 00 RA degrees eooo CEEE Dec degrees p 0000 Choose Positio
152. quencies above 1114 GHz extreme upper end of tuning range Band 5a LO frequencies near 2GHz 1135 GHz For data taken before OD642 14 February 2011 there is also a known issue around 2GHz 1206 GHz Band 5b LO frequencies below 1236 GHz and around 1GHz 1255 GHz Band 7a LO frequencies between 1755 and 1759 GHz Band7b Currently there are no known remaining purity issues but users should be aware that tun ings at LO frequencies above 1899 8 GHz suffer from a sensitivity degradation by about a factor 2 due to unavoidable mixer over pumping For most sources this should be far enough for tunings targeting the C line where robust tuning is now achieved in most cases Users should however be aware that the tuning success in the upper end of band 7b can be influenced by the chain thermal ization history and the exact targeted LO frequency So there could still be observations that will not benefit from the best sensitivity usually rendering the scientific data very difficult to exploit The scheduling implications are summarized as follows Spectral Scans in Bands 3b 4b and 5a may be carried out as is and Users should inspect and possibly discard the spectra taken at the unruly LO frequencies This will imply some noise degradation after the spectrum deconvolution For Spectral Scans in Band 7a the User is advised to split the frequency coverage into at least two AORs which avoid the impure areas As a consequence t
153. r 2a 29 Observing with HIFI User Inputs Target ON and reference OFF positions LO band and frequency minimum and maximum goal frequency resolution of the calibrated data spectrometer usage and total observing time or noise goal at the lowest goal at the goal resolution Data Calibration The final spectra are based on the differences between neighbouring ON target and OFF reference position measurements Co addition of ON OFF provide the final 1D spectrum A zeroth order baseline may occassionally need to be subtracted when using this mode No explicit standing wave correction is needed Instrument tuning frequency calibration and measurements of the internal hot and cold loads will be done during initial slew and may be done during slews between ON and OFF positions depending on slew length and rate The transformation into a brightness temperature scale is performed by dividing the difference mea surement by the results from the load calibration measurements and multiplying by the corresponding difference in the Rayleigh Jeans temperatures of the hot and cold loads for the given LO band loads are measured during each observation The final translation into a beam temperature relies on the beam efficiency as measured at the primary calibration sources 4 2 1 2 Mode l 2 Dual Beam Switch DBS Purpose Used to observe a point source fixed or moving in one or more spectral lines or continuum within
154. rast between higher and lower resolution data is illustrated in Figure 3 3 which shows spectra for the Orion Irc2 region J 7 Resolution 4MHz T 40 Resolution 1MHz R solution 1MHz EEE Care Y 1 400 Resolution Resolution s 100kKHz 300kHz yy Figure 3 3 Example of the use of high resolution spectroscopy in the Orion Irc2 region Wide Band Spectrometers WBSs The Wide Band Spectrometers have a single resolution 1 1MHz with pixels of width around 0 54MHz varies slightly across the IF bandwidth A total contiguous IF bandwidth of 4GHz is cov ered by 4 linear CCDs that cover 1GHz bandwidth each Precise frequency calibration is available via an internal comb generation supplying a signal providing a regular line spectrum with lines 1 OOMHz apart Two buffers are available for source and reference spectra High Resolution Spectrometers HRSs The High Resolution Spectrometers have configurations with a variable resolution that is user se lectable see Table 3 2 Between one and four subbands of 230MHz of 460MHz bandwidth can be 18 HIFI Scientific Capabilities and Performance centred anywhere within the 4GHz intermediate frequency range made available to the spectrometers Frequency calibration comes from the internal local oscillator frequency settings for the spectrometer Two buffers are available for source and reference spectra Table
155. rdware units the Focal Plane Unit FPU see 1 which is located on the optical bench in the Herschel cryostat and depicted in Figure 2 4 and Figure 2 5 the Up converter and 3 dB Coupler described in Section 2 4 are contained in the satellite s service module see the Observatory handbook for details on the service module and the Focal Plane Control Unit FCU also contained in the satellite s service module Additionally the critical signal chain elements that together define the instrument s sensitivity the mixers isolators in bands to 5 and amplifiers plus the IF up converter used in Bands 6 and 7 together form the HIFI Signal Chain HIFI Instrument Description 14 Mixer Sub Assemblies Diplexer Box 7 LO Beams Herschel Telescope Telescope Channel Calibration Source Assembly Figure 2 4 HIFI Focal Plane Unit FPU In practice the HIFI signal chain is a virtual unit since its elements are physically distributed through out the FPU The complexity of the FPU has necessitated a modular design in which the Focal Plane Unit is divided into six major assemblies the Common Optics Assembly the Diplexer beam com biner Assembly the Mixer Sub Assemblies of which there are 14 the second stage IF amplifier box the Focal Plane Chopper and the Calibration Source Assembly see Figure 2 4 Relay Optics Splitting inc the Focal Optics Plane Chopper 7 channels Commo
156. re observed in both frequency positions How ever the system response is likely to differ between the two frequency settings and simple spectrum arithmetic may not result in clean baseline removal and may potentially leave significant ripples in the difference spectrum This should be mitigated by observing both frequencies also at an OFF sky position at the same two frequencies The mode allows the user to specify a suitable OFF position which should be free of emission absorp tion line features It is highly encouraged that an OFF position be employed by users of this mode and good reason should be supplied in the proposal justification if no OFF position is to be used This is especially true for the diplexer Bands 3 and 4 in which the standing waves are not well fitted by one or two sine waves of constant amplitude Only if the User expects very strong lines and is not concerned by the standing wave pattern in the surrounding baseline or expects to be able to fit the standing waves in IA when the lines are narrow should the no reference option be considered This mode is more appealing for observations of complex astronomical environments where baseline removal cannot be accomplished with an immediately spatially available emission free reference OFF measurement as compared to the position switching or DBS modes Modes I 1 and I 2 A schematic timeline of frequency switch measurements is shown in Figure 4 5 Telescope OFF position MEHEL
157. rements were done in two steps e A coarse mapping was performed over an area around the expected aperture location on the sky allowing for mis pointing margins For this a sampling slightly worse than a Nyquist sampling was used Only one aperture per cluster was considered at a time e After correcting the offset measured from the coarse mapping a finer mapping was repeated with a smaller sampling and extent This time all 7 bands were measured see e g Figure 5 6 a 150 70 025 100 30 0 02 0 015 0 0 pa 0 01 400 0 005 150 100 0 100 10 Figure 5 6 Example of Saturn measurements in band 6 1625 GHz used to determine the offsets of the corresponding HIFI apertures on the observatory YZ plane focal plane 5 5 2 2 Beam Coalignment and Beam Width offers for each receiver two polarisation channels that can be measured simultaneously While they provide a hardware redundancy to cover contingency failures they can also be combined to decrease 60 HIFI Calibration the noise level achieved in spectral measurements by a factor of 2 This assumes that both polarisa tions are looking at the same point on the sky Because they correspond to two physically different mixers and their associated optics the co alignment of the respective apertures on the sky adds a po tential error Beam co alignment was measured simultaneously with beam width using Mars map informa
158. rize the problem since we have no sideband filter whenever we take a spectrum with HIFI we get the sum of two spectra one with the frequency axis ascending one with the frequency axis descending These spectra originate from the same general frequency regime with their bandpass centres separated by about 12 GHz for Bands 1 5 and about 72 GHz for Bands 6 and 7 around the LO For reference at the top frequency of band VI High at 1900 GHz 72 GHz is 1137 km s Difficulties with overlapping sidebands will occur during line surveys For example the crowded line regions of Sgr B2 and Orion are very rich in line information but the molecular emission and absorption lines will overlap and become blended This is known from CSO observations 17 and 106 Pipeline and Data Products Description 7 5 1 others Like HIFI the CSO has no sideband filter The capability to perform broad line surveys is one forte of HIFI and there will most likely be Legacy Programs using HIFI concentrating on line surveys of rich molecular line regions As to how many fainter regions will have rich or crowded line regions it is known that certain type galactic objects have such spectra but this issue needs more study Solving the Deconvolution Problem The problem can and has been solved 17 Since one of the two IF passbands is reversed there are multiple realizations of added spectra possible by shifting the LO in frequency a small amount within th
159. s A typical HIFI level product will contain such a set of scans f L 1 3 455 10 3 458 10 3 457 10 3 456 10 3 459 10 Raat Frequency MHz Mia bodes t es tee 3455 10 3 458 10 3 457 10 3 458 10 3 459 10 Rest Frequenc Figure 7 3 Typical level 1 calibrated scans from a single observation showing the different types of baseline problems that can occur in individual scans In Figure 7 4 two of the scans of Figure 7 3 are shown with a velocity scale The HIFI level 1 product should contain all information needed to convert frequencies to velocities and vice versa 104 Pipeline and Data Products Description Figure 7 4 Same as Figure 7 3 now with velocity in stead of frequency scale In Figure 7 5 an example of level 1 frequency switch data is shown In this observing mode the data taken at a different frequency rather than at a different position is taken as reference to be subtracted As a result the spectral lines are seen in emission here around 10 km s and absorption around 15 km s Reat Frequency MHz 8 732 10 i a N Figure 7 5 Typical single calibrated level 1 scan as obtained using frequency switch observations 7 4 Pipeline Processing 7 4 1 All HIFI data that arrives at the Herschel Science Centre will be processed through standard pipelines that are designed to take into account all known instrument properties in order to produce a f
160. s the target line s from one image band to the other Figure 3 4 illustrates the overall distribution of the receiver noise temperatures as measured in flight All temperatures are the median DSB receiver temperatures over the full WBS bandwidth in K Fre quencies are in GHz There are two types of poor sensitivity ranges More detailed information for each of the bands is provided in Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 and Figure 3 11 20 HIFI Scientific Capabilities and Performance 140 120 100 80 60 40 20 0 WBS H e WBS 480 500 520 540 560 580 600 620 640 Figure 3 5 Double sideband system system temperatures of HIFI mixers in bands 1a and b In plots up to Figure 3 11 the x axis provides the local oscillator frequency used in GHz and the y axis provides the double sideband system temperature in K 700 600 500 400 300 200 s eoo J 100 0 630 650 670 690 710 730 750 770 790 Figure 3 6 Double sideband system system temperatures of HIFI mixers in bands 2a and b 600 550 500 450 400 350 300 250 200 150 100 800 820 840 860 880 900 920 940 960 Figure 3 7 Double sideband system system temperatures of HIFI mixers in bands 3a and b 1100 1000 900 800 700 600 500 400 300 200 s WBS H gt WBSV 950 970 990 1010 1030 1050 1070 1090 1110 Figure 3 8 Double sideband system system temperatures of HIFI mixers
161. s whose brightness temperature distri bution is well known Celestial calibrators are generally used and for HIFI beam measurements have been made using Mars e to derive telescope efficiencies e to measure the half power beamwidth HPBW of the main beam and to measure the beam profile i e to map the point spread function 5 5 2 Beam Characteristics 5 5 2 1 Initial On Ground Measurements The in flight assessment of the HIFI aperture was highly reliant on the very accurate measurements performed on the ground during the Instrument Level Test ILT campaign During these measure ments the aperture positions were measured with respect to a reference alignment cube belonging to a common reference frame but most importantly the various bands were paired in clusters for which the relative positioning was measured with an accuracy better than 0 7 arcsec on the sky see Figure 5 5 59 HIFI Calibration HIFI Apertures Horizontal M3 center Vertical M3 center 100 50 6y arcsec xX x 100 L x Horizontal chopped x Vertical chopped 100 0 100 200 300 400 500 600 8z arcsec Figure 5 5 Projection of the beam intensity distribution onto the HIFI pick up mirror M3 as measured during the Instrument Level Tests Band 1 is to the left on this diagram and band 7 to the right This legacy results allowed to starting the in flight FPG measurements with only one aperture per cluster The measu
162. scheme assumes that there is a perfect match between the distance on the sky involved between the two chopper positions and the distance involved in the telescope slew Since the FPG measurements have been taken in the DBS mode it is possible to create two separate maps corre sponding to each telescope position and therefore derive any offset between the source positions in each coverage This offset is used to recalibrate the exact telescope slew distance needed to match the intrinsic chopper angle on the sky This is particularly important since there is some curvature involved when chopping away from the on axis line of sight and this effect varies with the HIFI band Figure 5 15 illustrates this result showing an excellent agreement between measured and theoretical throws on the sky 67 HIFI Calibration 0 00 20 00 40 00 60 00 80 00 100 00 120 00 Throw arcsec 140 00 160 00 180 00 200 00 Band Figure 5 15 Chopper throw distances on the sky Upper curves theoretical diamonds and measured squares distances for a so called half throw i e a chopper throw between the secondary M2 centre and one of the borders of M2 Lower curves theoretical triangles and measured crosses distances for a so called full throw i e a chopper throw between the two opposite borders of M2 5 6 Mixer Side band Ratio HIFI uses dual side band DSB mixers with a large IF 6 GHz and a large simult
163. seessesresrerrsrrsrrserrrrererreees 13 3 HIFI Scientific Capabilities and Performance sseseeesseerrsresrrseerreresrrerrereerrreesreersree 15 3 1 What Science Is Possible With HIFI eeseseesseesesersrseresrrerrrreserererrrreserererreseee 15 3 1 1 HIFTs Scientific Objectives scos ccrrsss ecse ae 15 3 2 Primary Instrument Characteristics ccc cece cece eee ce ecce cece cece eeaeeeueeeueeeneeennees 16 3 3 General Instrument Description 2 2 0 0 cess cc eecenece ences ceeeceeeeaeeeaeeeaeeaneeans 17 3 4 Available Spectrometer Setups eceesseeeceeeceescenscnsvensecnsensesseeresesneeeenesens 18 3 4 1 Wide Band Spectrometers WBSS csceeeeeeeeeceeceecereeeeresenereeeeneees 18 3 4 2 High Resolution Spectrometers HRSs cece cece ee cece eee eee eee eeeeee es 18 3 5 Mixer Performance s stosie teren EE coon ESETE ESTEE S KE poses ened SESE ESEESE Ete 19 3 5 1 System Temperatures vocr sssa okomi aeni a EE E EES 19 3 5 2 Tuning Ranges oeeie oiii dos raue ee oaeee VETE EEE EER EE ES 20 3 5 3 Sensitivity Variations Across the IF Band 0 ccc cece eeee ee eeeeeeeeeenee 23 3 5 4 Overall Noise Performance 1 2 0 0 00 e cee eeee ce eece cece ence eeceeeceeeeaeeeaeeeueeaneeaes 24 3 5 3 Mixer Stabiliiies sri ar sk adstas Po aT e EE E oe E EAS 25 4 Observing with HIFI est n e e O EE EEEE cess ends eee EEE EE E ETE 27 A l MirodUCt ON 233 rei reser reni Ea OE ESEE RED SPN sas s
164. selection There are a total of up to four spectrometers that can be used by HIFI in a single observation Two Wide Band Spectrometers WBS and two High Resolution Spectrometers HRS with one of each available for each polarization The user has several choices of spectrometer backends The rule of thumb is that the more spectrometers being used the slower the rate at which readouts can occur The HIFI software allows data to be taken at or near the limit of the data rates allowed by the system For all four spectrometers running at the same time this means a readout every 4 seconds or so The fastest readout rate in normal operating mode is once every second which occurs for the choice of a Half HRS spectrometer or in bands 6 and 7 for two WBS polarizations where the bandwidth is 2 4 rather than 4 0GHz The choices of spectrometer combinations available to the astronomer are e WBS and HRS all 4 spectrometers are used e WBS only just the 2 WBS spectrometers are used for when lower resolution data is sufficient e HRS only just the 2 HRS spectrometers are used for when only high resolution data is wanted e Half HRS only only the HRS is used and half the subbands made available in each polarization see below for notes on the HRS subbands This setup can be used when data needs to be taken at a higher rate 75 Using HSpot to Create HIFI Observations The HRS is able to be used in modes with several different resolutio
165. sibility to use one OFF calibration measurement for a series of source measurement 5 3 4 Non linearity In all equations and references mentioned above it has been assumed that the instrument response to any radiation field is linear Deviations from a linear behaviour are expected mainly in the IF branch including the spectrometers However from ground based measurements it was concluded that these deviations are not significant 1 or less and can in any case be measured and corrected in the data processing 5 3 5 Blank sky contribution The main contribution from the blank sky comes from the dust emission in the Milky Way which is the brightest extended source of radiation in the considered wavelength region For a typical Galactic OFF position 4 5 degrees from the Galactic plane at 500 GHz the continuum intensity corresponds to 10 K and thus is far from having any noticeable influence In sky regions closer to the Galactic plane the continuum intensity increases but remains insignificant Only in the direction of the Galactic centre the continuum emission becomes no longer negligible These numbers are based on the work of Schlegel et al 15 who obtained the spatial distribution of the dusty density and temperature combining IRAS and DIRBE data 5 3 6 Conversion between Antenna Temperature and Janskys The HIFI calibrated product as obtained from the pipeline is provided in antenna temperature TA To convert this to a
166. solution MHZ 1 10 Separate setup for each polarisation of HRS sub bands Ne z The HRS Mode for H or both polarisations Nominal Resolution z HRS Resolution MHz for H or both polarisations o 000 The HRS Mode for V polarisations Nominal Resolution HRS Resolution MHz for Y polarisation jeooo Figure 6 27 Instrument setup for Example 2 93 Using HSpot to Create HIFI Observations IIE x Frequency Editor Lower Sideband LO Frequency fesziso Upper Sideband ae ee on SD ACR FS erat free re ALEAT LEELEE COREE OORT COREE RENO LELLELLEEI SOROS AI 647 0GHz 649 0GHz 651 0GHz 653 0GHz 655 0GHz 657 0GHz 659 0GHz 661 06 634 G4 54 664 ome 634 694 704 714 Local Oscillator Frequency GHZ eee Reset Redshift 0 000028 Reset all frequencies Frequency Selection EE Line Transition U Observed GHz 18005 HeO wa x moa 2011 z f ssrsa1 Cancel Figure 6 28 Frequency editor initial setup on water line xi Frequency Editor Lower Sideband LO Frequency esz7i0 Upper Sideband IBS ON 647 0GHz 649 0GHz 651 0GHz 653 0GHz 655 0GHz 657 0GHz 659 0GHz 661 0GHz 634 Gg t 66a ora 634 694 704 714 Local Oscillator Frequency GHZ eee Reset Redshift 0 000028 Reset all frequencies Frequency Selection Line Transition U Observed GHz Rest GHz 18005 HeO va y oa 2011 z f ssrsa1 sss 0
167. solution mode the 4080 correlation channels are used to analyse 4 of the 8 input signals of 230 MHz band width each The four sub bands can be independently placed anywhere in the IF bandwidth In this mode with a Hanning windowing of the correlation function the spectral resolution is 500 kHz The total band width per HRS unit is 1 GHz In each correlator ASIC one channel is dedicated to compute the analogue signal offset 13 HIFI Instrument Description 2 5 2 4 Modes of HRS Operation Nominal Resolution Mode In the nominal resolution mode the 4080 correlation channels are used to analyse 2 of the 8 input signals of 230 MHz band width each The two sub bands can be independently placed anywhere in the IF bandwidth range In this mode with a Hanning windowing of the correlation function the spectral resolution is 250 kHz The total band width per HRS unit is 460 MHz In each correlator ASIC one channel is dedicated to compute the analogue signal offset 2 5 2 5 Modes of HRS Operation High Resolution Mode In the high resolution mode the 4080 correlation channels are used to analyse 1 of the 8 input signals of 230 MHz band width each The sub band can be placed anywhere in the IF bandwidth range In this mode with a Hanning windowing of the correlation function the spectral resolution is 125 kHz The total band width per HRS unit is 230 MHz In each correlator ASIC one channel is dedicated to compute the analogue sig
168. source flux in Janskys requires some knowledge of the beam at the frequency used HIFI beam information is discussed in Section 5 5 2 The formula for conversion is S T 326 9 na Jy K The value of na for each subband is listed in Table 5 5 5 4 The Frequency Calibration of HIFI The framework for the frequency calibration description of Herschel HIFI is given in 11 This doc ument presents the terminology related to this topic and recalls the principles and parameters to con sider for the HIFI frequency calibration Some of these parameters have already been introduced in the spectrometer description sections see Chapter 2 52 HIFI Calibration 5 4 1 Context In the frequency domain the observations are smoothed by the effective instrument spectral response This response is the combination of several spectral element responses along the detection chain prin cipally the Local Oscillator LO and the respective spectrometers having their own channel resolu tion profile 5 4 2 Frequency accuracy There are different frequency conversions in the instrument They are based on down and up conver sion performed by local oscillators some being internal to the spectrometers so their accuracy is di rectly related to these LO frequency accuracy For HIFI the Master LO has a frequency requirement of 1 part in 10 In bands 6 and 7 the use of an up converter adds another 50 kHz uncertainty in the frequency scale The
169. st chop up to 4Hz depending on the goal resolution being faster for larger resolutions and a slow chop typically 0 125Hz if all 4 spectrometers are used simultaneously but twice as fast if two backends are switched off e g WBS only The FPC is designed to have a settling time under 20msecs Figure 2 10 The HIFI Focal Plane Chopper FPC 10 HIFI Instrument Description 2 3 5 The Calibration Source Assembly Mounted on the side of the Common Optics Assembly the Calibration Source Assembly includes two blackbody signal loads that are used to calibrate the instrument s sensitivity the first is an absorber at the FPU temperature around 10K while the second is a lightweight blackbody cavity that can be heated to 100K plus mirrors that focus the FPU s optical beam into the loads Temperature sensors are available to read out the actual temperature of both calibration loads The HIFI optical beam is steered towards the calibration sources by the use of extreme positions of the Focal Plane Chopper 2 4 The HIFI Signal Chain As seen in Figure 2 11 the HIFI Signal Chain includes the 14 Mixer Units the First and Second Stage Amplifiers in the FPU the Upconverter and 3 dB Coupler which are located in the satellite s service module and the Isolators that are used to suppress reflections between the Mixer Units and the First Stage Amplifiers Kiwa AR 15Kievd 230 K SVM E A ne Ta st N virar amp 1 ae 2 ot 5
170. sta bility Allan times at the goal resolution of the system are less than 2 seconds This reduces observing efficiency User inputs The user has choice of frequency range within the mixer band frequency range chosen partial or full band The user can choose a redundancy of between 2 and 12 Higher values increase the fidelity of the final single sideband spectrum expected from the data reduction of the mode but also make the mode less efficient Fast chop and continuum timing for the DBS mode used are also available options Data calibration Data reduction consists of two parts the calibration of the double sideband spectrum see Sec tion 4 2 1 2 and the deconvolution of the set of double sideband spectra into a single sideband spec trum The calibration of the double sideband spectrum is identical to the calibration in the single point with dual beam switch see Section 4 2 1 2 applied for spectra taken at each LO setting Sideband deconvolution is provided via a data software task provided within the HIPE software envi ronment and takes place after each double sideband spectrum has been processed More information on the sideband deconvolution software are noted in Chapter 6 No ghost lines symptoms of instabilities or insufficient sampling have been found in any spectral survey so far When spectral artefacts and bad baselines are removed completely from the input prior to using the deconvolution algorithm in post processing t
171. t appropriate OFF spectra are selected from a database of observations based on mixer current level the current matching technique This approach should reduce the amplitudes of the residual standing waves considerably but is currently in development Presently the user may apply FitHifiFringe to remove the waves in Level 2 spectra This method has limitations because the HEB waves are not pure sine waves they disperse over the IF band i e their phase changes Figure 4 14 provides an example for HEB measurements using the Point Load Chop mode As can be seen the line shape in the WBS V and WBS H spectra differ somewhat after subtracting the sine wave fit This highlights another limitation of FitHifiFringe for broad lines covering much of the IF insufficient surrounding baseline may be left to obtain accurate sine wave fits In addition as for the diplexer bands solutions are less accurate for lines close to the IF band edge 1 1 1489 5 1490 0 14905 1491 0 14915 14895 1490 0 1490 5 1491 0 1491 5 Isbfrequency GHz Isbfrequency GHz Figure 4 14 A Band 6a Point Load Chop observation showing residual waves after standard level 2 pipeline processing left and after standing wave removal using FitHifiFringe right The fringe corrected spec trum has been shifted and a small scaling applied along the intensity axis so that the H and V peaks agree 4 5 Grouping or Clustering of Observa tions At the present time
172. t is the double difference of these two modulated spectra that finally offers a correction of the baseline ripples standing waves Error budget The error budget indicates the total error for the HIFI calibration It is dependent on the band maybe the frequency on the observing mode and on the source observed The budget includes both frequency and intensity calibration It also takes into account the uncertainty on the telescope pointing There are two types of error considered e Systematic Errors they are described within the calibration framework e g temperature sensor on hot and cold loads We presume multiple measurements will not improve these errors There are two ways to combine these error linearly pessimistic or quadratically uncorrelated errors The error budget for systematic errors are contained in Table 5 6 Note that line linearity has been found to be a negligible error e random errors the normal radiometric errors which are statistical in nature Multiple observations will reduce these errors The cost is time 71 HIFI Calibration Table 5 6 Overall error budget Current Error es Overall er Error source estimate timate ror impact 1 5 up Sideband ratio 0 5 to 15 for 3 0 30 diplexer bands Hot load coupling 1 00 1 2 0 87 Cold load coupling 1 00 1 0 0 13 Hot load temperature 100K 0 5K 0 54 Cold load temperature 15K 0 5K 0 46 Planetary model err
173. t need to be calibrated as the same optical path is used for source and reference Observations aiming at a determi nation of the continuum level have to rely on modes using the internal chopper such as the raster scan 4 2 2 2 Mode Il 2 Raster Maps with Dual Beam Switch Purpose Used to observe a small an extended source fixed or moving in one or more spectral lines or con tinuum within a single IF band Uses the fixed 3 sky reference positions either side of each raster position which limits the effectively useful size of a raster 38 Observing with HIFI Description In this mode a grid of positions are each measured using a dual beam switch method The mode works for each grid position in the same way as for the point source dual beam switch mode see Mode I 2 The beam switch samples sky at 3 arc minutes either side of each grid position with a telescope movement occurring between changes to the beam switch either side of the grid position With this setup large maps would find the beam chopping into the field of view so this is not a good mode for doing large extended emission region mapping Advantages It is a good mode for situations where fast chopping references are needed as may be the case for band 6 and 7 measurements or where continuum measurements are required for small extended sources or point sources In these cases scanning measurements may take too long allowing drifts to occur Disadvantag
174. tain simple readout counts versus channel pixel number Examples of such products are shown in Figure 7 1 for typical HIFI calibration scans for the zero 103 Pipeline and Data Products Description level the WBS comb spectrum used for the frequency calibration and the internal hot and cold load calibrators used to determine the intensity scale In Figure 7 2 typical on source and off source signal scans are shown COME 410 at ere eet 4 Figure 7 2 Typical level 0 raw data for single dish sub millimetre signal and reference source scans 7 3 2 Level 1 products In Figure 7 3 the calibrated scans corresponding to the data shown in Figure 7 2 are shown These were obtained by subtracting the reference from the source signal shown in Figure 7 2 and subsequently applying an intensity and frequency calibration derived from calibration scans as shown in Figure 7 1 Two panels are shown corresponding to a signal and an image band calibration Either of these two calibrations is appropriate for a double sideband receiver The astronomer will have to decide which of the two or both should be used for scientific analysis Figure 7 3 Typical narrow band single dish sub millimetre level 1 calibrated scans Figure 7 4 shows a set of calibrated scans for a single observation Clearly each scan has a different baseline and thus averaging cannot be done without correcting the baseline shape or even discarding some scan
175. tegration starts as soon as the telescope enters the blue area of the map Note the change of the scanning direction after each row For situations where an emission free OFF position is not immediately available the OTF scan with load chop scanning and comparing to frequent load measurements or frequency switch similarly scanning and switching frequency may preferably be used This is particularly useful for mapping using bands 6 and 7 where the short stability times mean that significant drifts can occur during a map scan leg Continuous reference to the internal load during a scan leg for example can help mitigate against such drifts and the increased associated with the drifts Advantages On the Fly scanning should be considered the standard mode for astronomical mapping with HIFI It provides the most efficient mapping scheme for HIFI Load chop and frequency switch versions can be useful in complex regions and when stability times are short e g in the HEB bands 6 and 7 Disadvantages and Alternatives Its use is problematic if no nearby position can be defined for an OFF position which is free of emission In this case it is often still possible and efficient to use an auxiliary nearby OFF position the emission of which is determined by a separate position switch observation However if the closest emission free region is too distant from the area to be mapped OTF modes with frequency switch can be more efficient The same h
176. tengeseetes T 49 5 3 The HIFI Calibration Scheme 0 0c cece ec cece cece cen ceneeeneeeeeeeeeeeeeeeeeaees 49 9 3 1 Internal Load Calibrations 20 5 s0 cs3seseccseceesscas ne ie ae 49 3 3 25 OFF Calibration sceon sosit nr E r E dat E Wes EE E ees enn 51 5 3 3 Differencing observations pores otira riers Esi sot osea PE PEESI EEEIEE vebeeeneses 52 HIFI Observers Manual 9 34 Nonlinearity esesta e in ENE EEE Weages EEEE on EEES EE ESERE 52 9 3 5 Blank sky contribution sissoscisisies eiai an a a boned eens 32 5 3 6 Conversion between Antenna Temperature and Janskys se ceeeererrereeeeee 52 5 4 The Frequency Calibration of HIFE 2 0 0 0 sosed rie ses pretep tresorer Resda eS ni 52 DAL CS COMLERE rnp eoan ES E EE eau EARE Rane ein 53 DA 22 Prequency Accuracy s reperica e T a a a E E E E a a EEE 53 5 4 3 Determination of Frequency Calibration cece cece cece cneeeeeee seen eenes 53 5 4 4 Frequency resolutions s s ieres naos saves sigs NEE sh ii ESPERE s EEPOS 53 5 4 5 Frequency and Velocity Verifications eesseeesseerrsresrrrrerrerrerrerrerereree 54 5 4 6 Spurious Responses in HIFI spei eseigi seinn Tp n p as 55 5 5 The Spatial Response Calibration of HIFI sesessseesseseeserrrsrrerrrrrrereresrereerreees 59 D911 EE KOI n ICS E E EE EE 59 9 5 2 B am Characteristics issi eesin iese e ins deestaeucdstalelecveas E EESE yat 59 3 5 3 Chopper Calibration ispintos E 67 5 6 Mix
177. the OFF position is subtracted from the ON source difference but in contrast to the load chop mode this double difference is not taken from the pure spectrometer counts Rather each measurement is translated individually into a temperature scale by applying the load calibration for the corresponding frequency setting Their mutual difference is computed only in the second step The double difference potentially cancels out all standing wave differences between the two phases but a perfect zero level baseline is only obtained if the system response as measured with the load calibration measurements agrees relatively well between the two frequency switch phases which is not guaranteed or at least not quantified until flight The double difference also guarantees a cancellation of all intensity drift effects that are purely lin ear within the corresponding cycle time However additional spectral noise will result from the dou ble difference and extra analysis time is likely to be required for the baseline calibration measure ment which will add to the noise in the calibrated data This may represent a considerable overhead if the goal frequency resolution of the observation is not much smaller than the resolution needed to determine possible standing wave ripples in the system 4 2 1 4 Mode l 4 Load Chop with optional OFF calibration Purpose Used to observe a point source fixed or moving in one or more spectral lines within a single I
178. the calibration strategy and equations applying to HIFI In the following we summarise the content of this framework 5 2 The Intensity Calibration of HIFI 5 2 1 The framework for the intensity calibration description of Herschel HIFI is given in 10 This docu ment defines the parameters at play in the intensity calibration approach and the various assumptions allowing the simplification of the formalism Here we provide an outline of the main components of the HIFI calibration framework Context In essence the HIFI intensity calibration approach inherits from the chopper wheel method introduced by Penzias and Burrus 14 which consists of relating backend counts of a differential on off source observation to the output of a hot also called the chopper stable temperature load compared to that of a colder one originally the blank sky Compared to this standard scheme HIFI faces the simplification that all contributions and instabilities from the atmosphere can be neglected Also many of the approximations used by the standard approach are not valid for systems with large IF frequencies such as HIFI and do not allow the high calibration accuracy required by HIFI to be met Moreover they do not exploit the full capabilities of an instrument with two thermal loads for calibrating the spectral bandpass Finally the standard calibration scheme contains no particular means to treat standing waves seen as ripples on the baseline o
179. ther correction to the spectrum depending on whether the signal emission line s of interest are in the upper or lower sideband of the instrument see Chapter 2 50 HIFI Calibration Table 5 1 Internal load couplings presently used Band Frequency GHz Nn H V Ne H3V 1 480 0 0 991 0 992 0 959 0 97 1 640 0 0 991 0 992 0 98 0 983 2 640 0 0 993 0 988 0 993 0 996 2 800 0 0 993 0 988 0 993 0 996 3 800 0 0 996 0 992 0 988 0 987 3 960 0 0 996 0 982 0 988 0 987 4 960 0 0 997 0 994 0 995 0 996 4 1120 0 0 997 0 994 0 995 0 996 5 1120 0 0 987 0 985 0 993 0 996 5 1280 0 0 987 0 985 0 993 0 996 6 1420 0 0 994 0 992 0 982 0 984 6 1710 0 0 994 0 992 0 982 0 984 7 1420 0 0 998 0 985 0 97 0 973 7 1710 0 0 998 0 985 0 97 0 973 5 3 2 OFF calibration In addition to the two internal load calibrations HIFI will use the observation of blank sky to reveal additional calibration information on the system In contrast to ground based observations where the observation of a reference position free of emission would provide mainly information about the at mosphere we can use such a measurement for a better characterisation of the instrument response itself In particular measurements on blank sky help in deriving information about the difference in standing wave patterns that are occur between the load measurement and the astronomical observation The idea behind this OFF measurement is that the
180. these are click on the line with the mouse see Figure 6 8 e The redshift being used is reported back to the user e A reset button to return to default frequency settings is available e At the bottom is a table that indicates the upper and lower sideband central frequencies being sam pled by the current settings e In the table are pulldown menus that allow specific spectral lines in the chosen mixer band to be placed at the best position within the spectrometer IF frequency range Choose the line and its transition e g CS and 39 38 After the second pulldown selection the user will be asked if they wish to move the LO setting Saying Yes will place the requested line at the best position for 77 Using HSpot to Create HIFI Observations the mixer band chosen either in the upper or lower sideband depending on whether the Upper sideband checkbox is ticked or not Figure 6 9 e NOTE Care should be taken to make sure the HRS subbands stay within the available IF range edges of the subband slider range at top left and right HRS 2 BS OW putnreryet Cl 1 0 w57 894 160651 pie Hz 457 507 Figure 6 8 Spectral line identification via mouse click In this case the red line was clicked on showing it to be a CI spectral line at the frequency 492 1607GHz I x Frequency Editor Fn Lower Sideband LO Frequency jiss Upper Sideband IF 24 IF 3 60 H20 331 904 v 1893 686512 AE B EO A E R EL SA A E ALA
181. tings during the observation Uses the dual beam switch sky referencing scheme sky positions 3 either side of the target Description The use of DBS reference inherits all the advantages and restrictions from the single point dual beam switch observing mode Mode I 2 The combination of telescope and chopper motions follows the same scheme and timing constraints as Mode I 2 This implies also that this spectral scan mode can only be applied to astronomical sources that are smaller than the chop angle of 3 arc minutes Each LO 41 Observing with HIFI frequency is separately calibrated against the internal hot cold loads of the instrument Extra observing time is spent at LO frequencies where the system temperature is significantly degraded with respect to the rest of the LO subband being used The user may choose to do all or part of a spectral range within a given band NOTE it is advised that the fast DBS chopping mode be used in association with bands 6 or 7 spectral scans Advantages Fast chop and continuum timing options allow for continuum measurements which are not possible with the frequency switch version of the spectral scan Thus also the most useful for measuring ab sorption line strengths Disadvantages and Alternatives The scheme has similar restrictions to other dual beam switch DBS measurements For extended sources the chopped beam is likely to land in an emission region Fast chop is required when the
182. tion col lected in the respective polarisation channels The results are summarized in Table 5 4 The co align ment is found to be very good and in perfect agreement with what was measured pre launch How ever in order to mitigate the global pointing error when combining the two polarisations it was de cided to not favour any of the channels and rather use an synthetic aperture located in the centre of the two polarisation beams The resulting coupling losses in such an approach are limited and listed in Table 5 4 Users are also referred to the technical note on HIFI beams on the Herschel Science Centre website at HIFI beam efficiencies Table 5 4 Beam coalignment results Band F FWHM AHVittr AHVriight Coupling loss GHz Y3Z Y Z 1 480 44 2 4 5 1 5 6 2 2 2 0 8 2 640 33 1 4 3 1 5 4 4 1 3 0 7 3 800 26 5 5 1 4 3 5 2 3 5 1 9 4 960 22 1 1 5 2 2 1 2 3 3 0 9 5 1120 18 9 1 5 3 6 0 0 2 8 0 8 6 1410 15 1 0 7 0 0 0 7 0 3 0 1 7 1910 11 1 0 7 1 5 0 0 1 0 0 2 5 5 2 3 H and V Profiles Contributing Sources To H and V Profile Disagreements The agreement between H and V profiles of lines observed during PV has been investigated with particular attention paid to an outflow source L1157 B1 which was originally observed in August 2009 and exhibited a deviation between the H and V line intensities of up to 20 This source was re observed twice during the second perfor
183. tion relative to the sky e The way to determine the direction of genuine polarization is to view a source at two of more different epochs along the telescope direction to rotate on the sky This will yield the desired result and can also verify whether the observed polarization is real or false The real polarization yields a full change in polarization direction over 1 4 year the false polarization produces a change in rotation direction over 1 2 a year These two rates can be distinguished by viewing the source on several successive occasions e The stability of the Herschel receivers appears to make this possible Both the real and the false polarization components have been detected with subband 1b and the system response did not appear to change noticeably over the half year period over which the false polarization became evident nor over the three week period over which the real polarization was being followed over a sky rotation angle of 30 degrees 5 5 2 4 Beam Efficiencies In order to complete the flux calibration of the HIFI receiver temperature account must be taken of the beam structure available in each band Reference 11 gives the definition of the various efficien cies required to calibrate the spatial response of HIFI the aperture efficiency Na the main beam efficiency Nmb and the forward efficiency n Efficiencies measure all losses relative to maximum gain in the system The aperture efficiency Na
184. to the table at the bottom of the Frequency Editor window Tick the Upper Sideband box in the same row On the first row next to WBS use the the two scrolldown menus to cheese the Line PE and sts transition Cr dane an the line scroll down menu gt you will be prompted as to whether you wish to change the frequency to the new position Answer Yes The slider automatically moves to locate the chosen line in the WBS band The Local Oscillator frequency becomes 1897 67 GHz See Figure 6 20 The CII line is NOT put in the centre of the upper sideband but is placed towards a better position in terms of sensitivity for the band chosen band 7b If you click on the brown and red lines shown on the frequency scale you can see where the CII and CS 39 38 lines will appear in the upper sideband Check all the desired lines targeted plus bonus lines are within both side bands If not move the frequency slider for the LO setting in order to do so Avoid locating lines in the middle of either WBS sub band area shown by dark rectangles to toa lere ciel Cea ETNE e gt in the present case CS 39 38 in USB and H20 331 404 in LSB are obtained for free see Figure 6 21 Locate HRS sub bands e g HRS1 on H20 un tick Upper Sideband since the line is only available in the lower sideband top left Select H20 then 331 404 from the two pulldown menus HRS2 on CS 39 38 line tick Upper Sideband
185. tral Scan AOT Ill Spectral scans consist of a series of observations of a fixed single target at several frequencies using the WBS as main backend After data processing the result of such an observation will be a continuous single sideband SSB spectrum for the selected position covering the selected frequency range The LO tuning will be advanced in small steps across a single LO band From a data analysis standpoint the reduction to a SSB spectrum is most reliable when the number of frequency settings within the instantaneous bandwidth of the instrument is high i e the frequency coverage is redundant This must be balanced with the loss of observing efficiency imposed by the dead times associated with retuning to each new LO frequency For most sources a reliable reduction of the line spectrum requires at least 5 frequency settings within the IF bandwidth i e a redundancy of 4 The spacings between the different LO frequencies have to contain a small random component to prevent harmonics which could occur in the reduction of the multiple double sideband measurements to a single sideband SSB spectrum in a deconvolution process This mode can use either a frequency switch FS or dual beam switch DBS reference frame to compensate for instrumental drifts Mode Ill 2 Dual Beam Switch Spectral Scan Purpose Used to observe a point source fixed or moving over a large frequency range gt 20GHz by the use of multiple LO frequency set
186. ttern in the Bragg cell crystal A laser beam which enters the Bragg cell is diffracted according to the acoustic wave pattern in the Bragg cell crystal The diffracted laser light is afterwards detected by four linear CCDs with 2048 pixels each and each covering approximately 1GHz bandwidth Four vertically aligned Bragg cells and CCD chains are necessary to cover the full 4 GHz IF bandwidth of HIFI The WBE electronic section has 4 analogue line receivers for the 4 CCD video signals These signals are fed to 14 Bit analogue to digital converter with a conversion speed corresponding to less than 3 ms The relatively high number of ADC Bit is meant to keep differential non linearity effects to a very low level Overall non linearity in the WBS is very low less than 1 Continuous data taking is possible without dead time during data transfer as long as the integration time is above 1 sec which is true for all standard operating modes of HIFI HIFI Instrument Description 2 5 2 Every 10 ms the collected photoelectrons in the CCD photodiodes are shifted into a register and clocked out serially After integration completion the data can be transferred while a new integration is started Data is transmitted to the Instrument Control Unit ICU with 16 or 24 Bits through a serial interface with 250 kHz clock rate which is synchronous with the CCD read out clock Housekeeping data is provided through the same interface A second serial interfa
187. tup of a HIFI Spectral Scan Observation ec e eee cence teen eeees 100 6 5 1 Example 4 Spectral Survey of a Hot Core cee ceee cence eeee teen es 100 7 Pipeline and Data Products Description 2 2 0 0 cece cee cee cece eee ceeece seca cece tenn eeueeenneennees 103 7 1 Data to be Passed on to the User 20 0 0 cece cee cc cece neceeeceeeceeeceeeeaeeea essa sean eeaes 103 7 2 Additional Observatory Meta Data cece cece cece eee cee ea eeceeeae eens eeneeeneeeenees 103 7 3 Example HIFI data products cece eeeceeec ence cece cena ceneeeneeeeeeeeeeeeeeeeseaees 103 732k Level O products ssis3 sachets en oeadesig sas soot a a bees aes seete yes Path hae 103 7 332 Level l products oian Fs Sn eh gh US Sea Seth peas eet EN ees 104 TAs Pipeline Processing sssri riren sche sg e assos oa R EENE ENES ESEE PSS PS E E S EPE 105 7 4 1 WBS Pipeline Processing Steps eseeesseeersseeserrresrerrsrrerrsrerrrrrerreerere 105 7 4 2 HRS Pipeline Processing Steps ecese iirin ap asia 106 7 5 Deconvolution Processing of Spectral Scan Data cece cece eee eneeee seen eenes 106 7 5 1 Solving the Deconvolution Problem 00 ccee cece cece ceeecseeeeeeneeeeeeeeeees 107 8 RELEPENCES i joies er ranee EEEE E venous lei deastayeehoh EEEE eee ea 109 As Change LOS morea ssacssatis satu tdeae vas banca aaa E A bok dadattatss ses er EA oe teadetaens 110 ANo codes te e5 tee aE Be SUT ees Sess Rh EEI Sis Se
188. ully calibrated set of data The following two sections indicate the basic processing steps that are expected to be done for the Wide Band Spectrometer WBS and High Resolution Spectrometer HRS WBS Pipeline Processing Steps The following processing steps are performed in modules starting from raw HIFI data frames obtained from either polarization using a WBS e 1 Bad pixels are corrected for e 2 Dark levels are subtracted from the 4 CCDs used in taking a single data frame This is based on the values of the first four un illuminated channels of CCD e 3 Non linearity of intensity scaling in WBS is removed 4 Zero frame subtraction A zero second bias frame is removed 5 Fitting of internal frequency comb with polynomial e 6 Apply frequency fit to frames to provide channel frequency scaling e 7 Apply attenuator setting correction e 8 Apply hot cold flux calibration e 9 Subtract reference spectra as needed e 10 Apply sideband gain correction based on ground based test information 105 Pipeline and Data Products Description e 11 Apply antenna temperature efficiency The end product is a set of double sideband spectra for an observation with flux measured as antenna temperature versus frequency An additional possible component to the pipeline is a module to remove known ripple structures from the data 7 4 2 HRS Pipeline Processing Steps The following processing steps are performed in m
189. upmendsseasaess ESPRES 27 4 2 The HIFI Observing Modes 0 0 00 0 useen ienei eies aeneae aneen 27 4 2 1 Modes of the Single Point AOT To cece cece neeeeeeeeeeeeeeeeeenees 28 4 2 2 Modes of the Mapping AOT ID 00 cece cee cc eee nece eee eeeeeeeeeeaees 36 4 2 3 Modes of the Spectral Scan AOT IID 0 ee eee cence eeca teen seen eenes 41 4 3 Standing Wave Residuals after Calibration Pipeline Level 2 eee 44 43 1 Bands 1 5 SIS Mixers j5s2 20s ose26 ane a a nthtavas atoiias cassie sss E E cattesau barcode 44 4 3 2 Position Switch Frequency Switch and Load Chop modes 000045 46 4 4 Bandss6 7 CHEB m1Xers os issccs dese esore ide deau asec veined tieeds acc se E EEE RA AEAT 47 44T DBS Modes sic sio boas oeae nnee tE Ea a EEE TEE EASE EE EE caste ees 47 4 4 2 Position Switch Frequency Switch and Load Chop Modes 000055 48 4 5 Grouping or Clustering of Observations cece cece cece ceeeceeeee seca sean eene eens 48 4 6 Solar System Target Modes is iccccscissstoisssss dsdesssevean deena sacssstetsasseadsawasseebes gees esos 48 5 AIT Calibration sosire ste lecsh ences ee Beds eb EEEE E EEE EST EE EES 49 S1 IMtroductione smir oeer aaie Sas thas aotte sh sored a santa sea ET sebeos 49 5 2 The Intensity Calibration of HIFI 2 0 0 0 cece ee cc eeceeeceeeeeeeseeeea essa sean eeaes 49 D201 SCOMLGKE ssc si ssie wale sete ogee Stacie voens g Sotaeessa shen asSsc
190. urces LDN1157 B1 in detail L1157 is a well known Class 0 proto star associated with an energetic outflow that displays shocked structures along its length including a bow shock in the blue lobe The velocity structure around the source is also complicated by in falling and accreting material Observations in the blue lobe of L1157 were made in Band 1b in Spectral Scan DBS mode with 1342181161 and without 13421811160 continuum optimization in August 2009 The two obser vations were well matched with each other but displayed a pronounced discrepancy in CO 5 4 H and V profiles reaching up to 20 in the line wings The profile discrepancy was still seen even after the peak in the H polarisation was scaled up to align with that in V profile with the V remaining stronger in the wing L1157 B1 was observed again in Band 1b 186 days later in performance verification using the PointFastDBS mode with continuum optimization 1342190183 and in PointDBS without continu um optimisation 1342190184 and the latter observation repeated again in the same 40 days later 1342192229 The roll angle of the telescope is 180 with respect to the PV 1 observations In all cases the V polarisation displays a higher intensity line than the H Figure 5 8 shows the H and V line profiles for observations 1342181160 160 1342190184 184 and 1342192229 229 scaled so that all the peaks per observation and polarisation align 62 HIFI Calibration
191. ured by temperature sensors on the internal hot and cold loads and np and Ne indicate the coupling of the beam to the hot and cold loads At this stage of our calibration we have made the following assumptions e the load coupling coefficients are similar in both side bands Load coupling for the hot and cold loads was measured during on ground testing The coupling coefficients are very close to 1 Values currently used in the pipeline are shown in Table 5 1 e the standing wave pattern does not change between the two thermal loads This is only partly true since the optical path between the mixers and the respective loads will differ by about 10mm Gen erally the standing waves arising from the load surfaces are expected to be negligible enough to show only as second order contributions Actually the dominating error factor in bands 1 and 2 are such standing waves For strong continuum sources there is a strong beat between 92 and 98 MHz ripples from the loads appearing in the spectra In the future there may be a user selectable alternative calibration scheme that would avoid introducing those standing waves from the loads into the science data for e g strong continuum sources e the side band ratio are normalised i e it does not define the ratio between the two side bands but the ratio between the response in one side band and the combined response in both side band Side band ratios are measured on the ground and would provide a fur
192. utions and refer ence bandwidths Band sii ee Spectroscopic stability time secs Full backend Full backend 1GHz bandwidth fia les hs Jos leso Jao fiso 70 0 i200 J550 1b 6 5 3 6 0 8 46 0 30 0 10 0 150 0 99 0 37 0 2a 14 0 8 7 2 2 71 0 48 0 16 0 300 0 220 0 193 0 2b 7 1 3 6 1 0 35 0 19 0 6 2 160 0 188 0 29 0 Ba h34 2i loz hso Jo as leso laoo tiso 3b 6 5 5 0 1 5 65 0 50 0 15 0 250 0 200 0 72 0 4a 1 8 1 4 0 5 9 1 7 3 2 6 120 0 98 0 38 0 4b 7 8 3 1 0 6 59 0 26 0 6 5 240 0 120 0 136 0 la l3o 44 loo moo Jasso fizo f3ioo 160 0 60 0 5b 12 0 4 3 0 9 82 0 39 0 13 0 210 0 120 0 155 0 6a 1 3 0 6 0 2 11 0 4 9 1 7 32 0 15 0 5 4 6b 2 8 0 8 0 2 42 0 15 0 4 4 91 0 43 0 17 0 la hs los loi z0 lso lz25s leoo 250 hsi 7b 0 3 0 1 0 0 12 0 3 8 1 1 33 0 10 0 3 0 The Allan stability measurement compares the instrumental drift with the radiometric noise After one Allan time we find equal contributions from radiometric noise and drift noise to the total uncertainty to the data An optimum measurement cycle should last about 1 3 of the Allan time for details see 18 Table 3 3 lists some relevant stability times as a function of the HIFI band and the reference As the radiometric noise decreases as occurs when binning multiple spectrometer channels for a coarser goal resolution we always find a decrease of the Allan time and the corresponding observation cycl
193. vidual integrations are affecting the profile in the wing then the fractional difference should increase there E aE Foret a ao De mm i a a ed a se 0 8 F borilisilis a E T OOO E A a a 5330 5332 5334 5336 5338 5340 5342 5344 5346 5348 5350 5352 frequency MHz Figure 5 13 H Haverage Haverage for the Off position for 1342190184 ia 2 fo boa 2 a bo bt 2 ha ot 2 be bh kk ba 22 rr wutiubuibiuti om CU EEEE IERE PA Fee es Pe ae DV S O EO Nor TESE OEE SEN ON E Wey UR YOR SE ener iA 5332 5334 5336 5338 5340 5342 5344 5346 5348 frequency MHz Figure 5 14 H Hav Hav for the On position for 1342190184 The spread is greater at the low frequency end of the line than for the Off position this may be due to the emission in the chop position The fractional difference reaches and even exceeds 0 1 in the wing of the profile compared with lt 0 05 near the line peak In band 1 the offset between the H and V beams is 6 2 2 2 It seems reasonable that if a scatter in pointings can give rise to a difference in one polarisation between ON and OFF positions then this further difference in pointing in H and V could cause differences in H and V profiles Furthermore if the chop direction was along the outflow as was the case for 160 and 184 this could generate a significant difference in H and V in the wing of the profile Summary and Conclusions on Profile Differences With Polarization Com
194. vity The user can override this if he she chooses e g to allow further spectral lines to become available in the same spectrum by use of the slider or by inputting a specific frequency in the frequency editor table for a given spectrometer see the user manual for details Overall Noise Performance HSpot provides noise estimates on a single sideband SSB main beam brightness scale for combined Hand V polarization spectra Observations carried out during performance verification were analysed 24 HIFI Scientific Capabilities and Performance in order to verify these predictions which drive observing time at goal and maximum spectral reso lutions entered in HSpot by the User The 1 GHz reference option has almost always been used in the noise predictions which means that the baseline in only one WBS sub band is considered for sta bility instead of the full IF to take standing waves within that 1 GHz window into account This is recommended for most observing situations except when lines are very broad such as from external galaxies or fast outflows Noise estimates from HSpot 5 0 have been found to be consistent with those actually observed using the various HIFI observing modes 3 5 4 1 Noise Performance in Spectral Scans 3 5 5 The noise in the Spectral Scans when measured before sideband deconvolution scales with 2 x redun dancy to the single sideband SSB noise when the gains are equal 0 5 When the gains dev
195. with a sufficiently small period it is guaranteed that the drift noise is small compared to the radiometric noise of calibrated data The conversion into brightness temperatures is performed on the basis of the counts from the thermal load measurements 4 2 1 3 Mode l 3 Frequency Switch with optional OFF calibration Purpose Used to observe a point source fixed or moving in one or more spectral lines within a single IF band Uses a switching between two LO frequencies for reference Useful when no sky references immediately near by Can not be used for continuum measurements It is highly recommended that users always use an OFF reference position whenever possible with this mode 32 Observing with HIFI Description In this mode following an observation at the requested frequency the LO is adjusted by a generally small amount a frequency throw as specified by the user causing the spectral region sampled by the spectrometers to likewise be adjusted by the same frequency throw The frequency shift should be chosen so that it is small enough that the lines of interest remain observable at the two LO frequencies and that lines do not overlap from the two phases Differencing of the two spectra can be used to effectively remove the baseline Since the second frequency position also contains lines of interest these appear as inverted lines in the difference measurement The mode is very efficient since target emission lines a
196. xample in its nominal resolution the HRS proves two sub band spectra each of which have a bandwidth of 230 MHz each of which is covered by 2040 channels and has a spectral resolution of 250kHz It is possible to set each sub band frequency independently anywhere in the 4 GHz IF band range Two buffers are used with selection synchronised with the chopper position by the ICU The HRS has a maximum chopping frequency of 5 Hz The data can be accumulated in each buffer up to a maximum of 1 95 seconds The data readout duration is about 42 ms Data can be read out from one buffer while data accumulation occurs on the other 2 5 2 2 Modes of HRS Operation Wide Band Mode In the wide band mode all 4080 correlation channels of the ACS are used to analyse the 8 input signals As the input signals are adjacent two by two 4 sub bands of each of 460 MHz bandwidth can be analysed in this mode The four sub bands can be independently placed anywhere in the IF bandwidth range It is possible to analyse almost the whole 4 GHz input IF bandwidth by selecting the same polarization in the two HRS units and by setting the lose to have adjacent sub bands In this mode with a Hanning windowing of the correlation function the spectral resolution is 1000 kHz The total band width per HRS unit is 2 GHz In each correlator ASIC one channel is dedicated to compute the analogue signal offset 2 5 2 3 Modes of HRS Operation Low Resolution Mode In the low re
197. z v hy y 160 y hylv 184 v hyv 229 V pol 160 H pol 160 Figure 5 9 Fractional differences in H and V profiles approach 30 160 10 184 and 4 229 The H and V profiles of 160 are plotted to illustrate the variation across the line The discrepancy at the peak of the line is very similar for 160 and 229 and is approximately 8 but is only 4 for 184 This could be an effect of the emission in the chop position see next bullet There is a clear dip before the line peak in 184 also seen in 1342190183 and a hint of the same in 160 e Investigation of the reference positions at Level of pipeline processing show that there is emission in the reference position when chopping off the source for 184 see Figure 5 10 e There is no emission is the reference positions for 229 e The H and V profiles in 184 and 160 show some discrepancy at frequencies below the line shift while 229 does not this effect is due to the emission in the chop position e The contaminating emission does not affect the line profiles in the wing There is no evidence of differing levels of emission in the two reference positions but this does not preclude the possibility that both reference positions contain an equal level of emission However this shows that the differences in profile in the wing are not a product of chopping into source 63 HIFI Calibration 5 T T T T pe i T T T T T T T T T T T I T T T i 9 T T T T T E