Home
Dale E. Berg+,Mark A. Rumsey: Wind Energy Technology
Contents
1. REFERENCES 1 Berg D Rumsey M Robertson P Kelley N McKenna Ed and Gass K Development of a Light Weight Wind Turbine Rotor Based Data Acquisition System Paper AIAA 98 0051 Proceedings of 1998 ASME Wind Energy Symposium Reno NV January 12 15 1998 pp 238 249 2 Berg D E Robertson P J and Ortiz M F Development and Application of a Light Weight Wind Turbine Rotor Based Data Acquisition System Windpower 98 Proceedings Bakersfield CA April 27 May l 1998 3 Berg D E and Robertson P J Precise Time Synchronization Data Acquisition with Remote Systems Proceedings of 1998 International Telemetering Conference San Diego CA October 26 29 1998 4 Berg D E Robertson P and Zayas J ATLAS a Small Light Weight Time Synchronized Wind Turbine Data Acquisition System AIAA 99 0050 Proceedings of 1999 ASME Wind Energy I Symposium Reno NV January 11 14 1999 pp 236 242 National Instruments Corporation 11500 North Mopac Expressway Austin TX 78759 3504 telephone 512 794 0100 URL www ni com ACRA Control Corporation Landscape House Landscape Road Dublin 14 Ireland telephone 1 353 1 2951264
2. ADAS II software can be read directly into SDAS in effect enhancing the capabilities of the ADAS II program The SDAS program is intended to complement other existing NREL analysis programs such as GPP Genstats and Crunch which can also read ADAS II time series files SDAS is an interactive stand alone LabVIEW program It is a unique data acquisition program instead of acquiring data from hardware as is normally done SDAS acquires data created or acquired by other programs usually but not necessarily the ADAS II data acquisition program One of the concepts that is built into SDAS is the ability of the program to know what data have been taken in a way SDAS maintains a global picture of what data has been acquired SDAS is designed to receive a continuous stream of time series files either from the ADAS II computer program in pseudo real time typically but not necessarily every 10 minutes or off line from archived time series files SDAS can calculate and store an extensive set of user selected statistics for every time series file All Statistics are stored in a central database that can be accessed later by the user SDAS will allow a user to interactively interrogate the database or any time series file that was previously processed by SDAS This gives the user the ability to perform a large number of tasks including looking at statistics looking for trends finding extrema looking for particular events performin
3. The time series files could be located in the computer folder where the ADAS II software is storing current time series files in another computer folder or on a CD R or a floppy disk SDAS Database In SDAS a database is the cumulative collection of information obtained by a sequence of acquisitions of time series data Each database is a knowledge base of information about a specific grouping of data For instance if you have processed data from both the Bergey 850 and the Zond Z 56 wind turbines you d probably want to separate that data into at least two groups one for each turbine SDAS gives the user the ability to create and maintain any number of databases However only one SDAS database can be open at any given time while SDAS is running The SDAS database is based on the Microsoft Access database format and thus can be read by Access SDAS communicates with the database through the SQL and Microsoft Open Database Connectivity ODBC driver interfaces However all of this is transparent to the user There are no database query commands to remember and Microsoft Access does not need to be installed on the computer in order to run SDAS SDAS Post processing SDAS has several post processing capabilities Four different kinds of XY plots can be displayed each with one to four channels per plot and they can be interactively manipulated They can be Statistic versus Time Channel versus Time Statistic versus Statist
4. for each sample and the internal 8 MHz clock In general this rate is slightly higher than the user specified one In the example in Figure 7 the user has requested a 30 Hz sample rate The actual rate based on the 8MHz clock and 48 channels of 16 bit words 12 bits of data and 4 bits of blank fill is 30 02 Hz However since the data acquisition signal is synchronized with GPS time every second the result is exactly 30 samples each second Clicking on the OK button will again return the user to the front panel ATLAS MicroPro Signal Setup Figure 6 Set Test Signals Window Notice the Review button on the bottom right At this time the user should save all of the input information with the Save button This creates an ASCII PCM file that contains all of the information gathered from the user and necessary to program the hardware The PCM Editor button in the front panel launches Notepad a text editor to allow the user to view this file Expert users may also modify the file manually After the PCM file is saved the hardware is Hes sw EES SOLE LTO OT TE SSRI SE SR OU ETT ET BI AE TORT SRE ER ee 1 RE OE ed r programmed with the Program button Ifthe ATLAS system contains only one DAS unit ATLAS will immediately start to program the hardware over the RS 232 link If the setup contains slave units ATLAS can program the entire system sequentially or just individual DAS units as specif
5. making a wide variety of reliable measurements in rugged environments using equipment of unobtrusive size and minimal weight e Provides stand alone operation by incorporating telemetry and battery packs that can be recharged on site e Provides the capability to acquire and save data to disk at rates up to 12 500 samples per second enabling the recording of contiguous long period time records so unexpected transients will not be missed and available testing time is not wasted e Provides an easy way to get experimental data into a standard PC data file format thus enabling users of varied computer skill and experience levels to use any standard PC based software products to perform post processing analyses and displays Additional information on the ATLAS hardware development may be found in references 1 4 Post Processing and Figure 1 Schematic of Typical Wind Turbine Data Acquisition System The ATLAS hardware is only part of the system In order to tailor the system for wind turbine use and make it user friendly and flexible powerful user irteractive software is required As mentioned in the earlier references we have chosen to develop the software in the National Instruments LabVIE for Windows environment both to facilitate the development of a single data acquisition software system the ADAS II software for this and other hardware systems and to utilize LabVIEW s power to develop a robust and friendly user i
6. SAN OFP ZEG4EC AIAA 2000 0052 HARDWARE AND SOFTWARE DEVELOPMENTS FOR THE ACCURATE TIME LINKED DATA ACQUISITION SYSTEM Dale E Berg Mark A Rumsey Wind Energy Technology Department Sandia National Laboratories Albuquerque New Mexico Jose R Zayas General Technology Corporation y E SST Albuquerque New Mexico ABSTRACT Wind energy researchers at Sandia National Laboratories have developed a new light weight modular data acquisition system capable of acquiring long term continuous multi channel time series data from operating wind turbines New hardware features have been added to this system to make it more flexible and permit programming via telemetry User friendly Windows based software has been developed for programming the hardware and acquiring storing analyzing and archiving the data This paper briefly reviews the major components of the system summarizes the recent hardware enhancements and operating experiences and discusses the features and capabilities of the software programs that have been developed INTRODUCTION Personnel in the Wind Energy Technology Department at Sandia National Laboratories a part of the National Wind Technology Center NWTC began the development of hardware and software for a new state of the art wind turbine data acquisition system in late 1997 The primary design goal of the new system was that it be capable of acquiring long term continuous multi channe
7. ansfer data over distances of up to one kilometer while TTL can be utilized if the transfer distance does not exceed about 20 feet TTL must be utilized if telemetry is being used The user also can enter a description 255 characters or less of the data acquisition configuration When these settings are complete the user clicks the OK button and is returned to the front panel ID ATLAS MicroPro Settings ese pro Settings id ae FO A Ss Figure 5 MicroPro Settings Window The next step defines the data acquisition signals done with the Set Test Signals button which brings up the window shown in Figure 6 The user selects a module and creates a data channel with the specific information required for that channel This information includes channel name filter settings excitation voltage amplifier gain etc At any time in this process the user can view the signals that have been definec in the Review window and edit or delete any existing signals After all of the signals have been defined the user clicks the OK button and again is returned to the front panel The last step is to select the sampling rate all channels are sampled at the same rate done with the Set Data Rates button which brings up the window shown in Figure 7 After the desired data rate is specified the software computes the closest data rate that can actually be realized given the number of bits being acquired
8. cond strike which was powerful enough to fry the turbine controller damaged a couple of modules in a tower mounted GBU next to the controller but the ATLAS damage was far less severe than in the first strike For a variety of reasons the AOC turbine was still not back in operating Status at the time the time of writing As a result we do not have much actual data at this time from which to draw operating experience Reliability of the system hardware has been a problem during the last year We have experienced several failures in both the TTL and RS 422 communications hardware Most of the failures appear to be the result of electrostatic discharge ESD not due to lightning but due to handling in the low humidity environments found in Bushland and Albuquerque ACRA Control has responded to these failures by identifying less susceptible components for some circuits and adding protection for others In fact ACRA s new Series II line introduced late in 1999 includes many design changes to address these problems Our biggest concern during normal operation has been the possible loss of telemetered data from the RBU which transmits a data frame each data acquisition cycle This frame is merged into the master data frame which goes to the GBCU If the RBU frame is not received the master frame will contain the last RBU frame that it received Since we are including data acquisition time in the data stream from the RBU it
9. er energy density but less robust lithium ion cells With this battery pack and the sleep mode of the new PLDS card we could run the AOC rotor unit for a full week 168 hours assuming we acquire no more than 8 hours of data the unit is in sleep rnode for 160 hours or more The system will provide power for about 18 hours of continuous data acquisition We have not yet had the opportunity to gain any field experience with this unit ATLAS SOFTWARE PROGRAM The computer requirements necessary to run the ATLAS software package are e Pentium 200MHz or faster e 32Mb of RAM 64Mb recommended e 20Mb disk space e 800 X 600 minimal resolution with small fonts 1024 X 768 recommended e Windows 95 or 98 The ACRA Control KAM 500 also sold in the US as Nicolet MicroPro that we use for the DAS unit was supplied with a rudimentary 16 bit DOS based programming data acquisition software While this software was adequate for initial system development it was apparent that we needed to develop software that would operate under and take full advantage of the 32 bit Windows environment The new ATLAS software written in LabVIEW allows the user to specify the hardware configuration of all the DAS units to specify the setup actual hardware gain filter setting etc for each channel and to actually program the DAS units to acquire the desired data Figure 3 shows the front panel of the ATLAS software From here the program takes
10. g Rainflow analysis plotting channels or statistics against each another investigating point by point details in time series files determining file commonality redundant time series files and dissecting concatenating and archiving time series files SDAS Computer Requirements We knew up front that SDAS could possibly be required to handle large data files thus requiring it to have large system memory requirements SIDAS was written to optimize computer memory wherever possible SDAS is also graphics intensive It will run on a computer with the following minimum capabilities e Pentium 200MHz or faster e 64Mb of RAM 128Mb recommended e 25Mb disk space plus necessary disk space for data storage e 1024 X 768 minimal resolution with small fonts e Windows NT Only one time series file at a time is read into the SDAS memory during an SDAS acquisition and up to four time series files can be read in at a time during post processing The only potentially large files that SDAS creates are the SDAS databases which start out at 74 kilobytes each and grow at a rate of 2 kilobytes for every time series file acquired and processed SDAS Status Window The main window in SDAS called the SDAS Status window is shown below in Figure 12 The dynamic settings of SDAS as they are set and changed are displayed in this window All of the functions available in SDAS can be reached from this window through the File Acquisi
11. ic and Channel versus Channel An example of a Channel versus Channel plot with four channels displayed is shown in Figure 16 The arrays generated by the Rainflow analysis are plotted using LabVIEW intensity plots Figure 16 Channel versus Channel Plot Four strain gauge channels are plotted against a fifth strain gage channel All the powerful LabVIEW graphics functions are available to modify the view of any of the plots zoom panning cursor measurement auto scaling etc A Microsoft Excel spreadsheet can be generated from the windowed data in any plot Conditions filtering is the name we have given a powerful capability which is similar to the triggering capability of the ADAS II program The user can set criteria or limitations on the data displayed in effect filtering information from the database The criteria are user selectable and are based on a logical combination of any SDAS calculated statistic from any channel and the time the file was created A number of SDAS file manipulation utilities are also available to the user For example the user can dissect concatenate and edit time series file generating new time series files There is also a powerful data archiving function which permits the user to compress or zip if so desired time series files and write them to CD R SDAS and Power Failures Because SDAS may be operated unattended for long periods of time the program was written with the capabili
12. ied by the user Programming DAS units individually can be useful if a configuration modification to only one unit in the system is made Figure 7 Set Data Rate Window The program versatility and simplicity allows the user to program an entire data acquisition system in a short amount of time Another key feature of the ATLAS software is the ability to monitor and or control the GPS module which is only activated if the user has selected the 7010_GPS_RevC module in the Configure Hardware window In this case the DAS unit in which the PLDS module is located is actually controlled by the signals generated by the PLDS utilizing the values calculated from user input in Set Data Rate window The GPS Data button on the Front Panel window then permits the user to monitor GPS data and to switch the PLDS communications mode from the GPS Communications window Figure 8 From this window the user can command the PLDS communication lines to perform one of several possible actions e transmit the incoming GPS data to the ground computer program the DAS hardware transmit the DAS acquired data to the GBCU serially eae i a e e return the unique PLDS logic software ID information Figure 8 GPS Communication Window GPS data transmitted to the GBCU is displayed in the GPS Communication window The GPS Valid button in the lower right of the window will turn from red to green when the GPS receiver is ac
13. is relatively easy to spot drop outs we simply run a program to check the RBU acquisition times and report all data points for which the interval between acquisition times is too long Examination of a 20 minute data file we acquired from the AOC shows just 12 RBU drop outs in the 36 000 frames of data recorded Each drop out was for a single frame the preceding and succeeding frames were received correctly TRANSFER OF TECHNOLOGY We are currently writing user s manuals for both the hardware and software and we plan to make the ATLAS and SDAS software available for use by NREL and others in the near future The plans part lists specifications and wiring diagrams for the RBUs and GBUs that we have built will be in the user s manual and we will be available to assist customers with assembling ATLAS units for their articular application SUMMARY Several enhancements have been made to the ATLAS wind turbine data acquisition hardware Changes to the mounting of the GPS receiver provide greater flexibility on antenna mounting location and changes to the PLD now enable the user to program the system via telemetry Addition of a sleep mode and a 48 emp hour battery pack enable a rotor based data unit to operate on battery power for up to a week between battery pack replacements A suite of LabVIEW based software routines has been assembled to complement the recent advancements in data acquisition hardware The ATLAS softwa
14. l time series data from operating wind turbines We have developed the Accurate Time Linked Data Acquisition System ATLAS hardware and software to achieve this goal This work was supported by the U S Department of Energy under contracts DE AC04 94AL85000 and DE AC36 83CH10093 t Principal Member of Technical Staff Associate Fellow of AIAA Senior Member of Technical Staff This paper is declared a work of the U S Government and is not subject to copyright protection in the United States A complete wind turbine data acquisition conf guration typically contains several data acquisition subsystems DAS Normally a system configuration wrilizes at least one rotor based DAS unit RBU at least one ground based DAS unit GBU and one ground based computer unit GBCU as illustrated in Figure 1 The RBU is mounted on the rotor rotating with and in close proximity to the blade and main shaft mounted strain gauges and other sensors The GBUs are any and all data acquisition units that don t mount on the rotor a GBU could be mounted in the turbine nacelle on the turbine tower or on the meteorological tower All acquisition units are located close to the sensors from which they are acquiring data in order to minimize contamination of the data by electrical noise picked up by long signal wires The ground based control unit GBCU is the heart and brains of the system The GBCU queries the user to determine the configuratio
15. leteness or usefulness of any information apparatus product or process disclosed or represents that its use would not infringe privately owned rights Reference herein to any specific commercial product process or service by trade name trademark manufacturer or otherwise does not necessarily constitute or imply its endorsement recommendation or favoring by the United States Government or any agency thereof The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof DISCLAIMER Portions of this document may be illegible in electronic image products Images are produced from the best available original document OE pe ee near Amarillo Texas Prominent features of the ATLAS include e Provides a complete integrated package using off the shelf components thereby minimizing custom electronics design system integration and software support and development functions e Provides flexible expandable hardware that can be integrated with common experiment control software to provide necessary quick look data display processing and analysis capabilities e Decreases the time and effort required to instrument a field experiment perform calibrations verify data validity collect data and do preliminary data analysis improving the end to end accuracy of data collected in field experiments e Provides a versatile system capable of
16. ll be calculated and stored the absence of an X indicates the statistic is not calculated or stored The vertical list of channels in this window except the yaw error is read in from a time series header file or a previously saved Statistical Analysis Configuration file The Cross Channel Statistics are selected or deselected in the same manner as the simple statistics described above As can be seen in Figure 14 the yaw error is the only cross channel statistic selected For example for the yaw error statistic to be calculated SDAS needs to map two variables to two data channels done in the SDAS Cross Channel Statistics Configuration window shown in Figure 14 This window is reached by clicking on the button labeled Edit Cross Channel Statistics along the bottom of the Statistical Analysis Configuration window Notice the yaw error variable wind direction degrees has not been assigned to a data channel yet but the yaw error variable yaw angle degrees is about to be assigned to the data channel rotor yaw angle degrees from the pull down menu that lists all the data channels After the yaw error statistic has been configured the yaw error will now appear in the Statistical Analysis Configuration window See the bottom entry in Figure 13 At this point any simple statistics can be selected deselected for the yaw error statistic gt Statistical Analytis Configuration Figure 13 Statistical A
17. n of each DAS the channels to sample the channel gains offsets and filters and the rate at which data is to be sampled programs each DAS to perform the acquisition performs calibrations retrieves and collates the data acquired by each DAS and displays and stores that data to disk The smart data acquisition system SDAS retrieves that data from disk post processes it and archives it ATLAS utilizes commercially available data acquisition telemetry and global positioning system GPS receiver hardware together with a custom built programmable logic device subsystem PLIDS to acquire long term time series data from multiple data acquisition units The PLDS utilizes the GPS receivers to maintain precise time synchronization between the various DAS units forcing data acquisition on all units at exactly the same time over the entire duration of a test An ATLAS prototype with a mixture of Windows and DOS based software has been installed on the Atlantic Orient Corporation 15 50 wind turbine at the U S Department of Agriculture USDA Agricultural Research Service ARS site at Bushland RECEIVES DEC 2 7 1999 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government Neither the United States Government nor any agency thereof nor any of their employees make any warranty express or implied or assumes any legal liability or responsibility for the accuracy comp
18. nalysis Configuration Window This allows the user to define the statistics to be calculated for each data and calculated channel D Cross Channel Statistics Configuration Fie 34 a oE E FA a Re TOE EI OD OS NY a RAIN i Mere cae E Ab eee ae eS sfeteeedecaar tre gt aire tere Ree TE Heada p37 Figure 14 Cross Channel Statistics Configuration Window The yaw angle variable is about to be mapped to the rotor yaw angle cata channel Notice also in Figure 13 that two boxes in the Rainflow column have been selected with an X in the last column for the blade 1 root strain gauge ancl blade 1 tip strain gauge channels This means two data channels have been selected for Rainflow analysis and must be configured The Rainflow configuration window appears in Figure 15 The fields in this window have been user configured in the same way as described above P Rarik Analy sit Contupsain Screen ety Of GF acd Ds wea Not Cab SB faethe bas atch iE akan Bat Figure 15 Rainflow Analysis Configuration Window The user defined parameters for a rainflow analysis for two data channels have already been set in the Statistical Analysis Configuration window After the user has configured the SDAS acquisition by selecting and mapping the statistics SDAS is ready to start acquiring time series data The time series files can be acquired from a user designated location on the local computer or over a network
19. nterface Some hardware deve opments have been accomplished during the months since the last paper on this system was published but most of the development has been on the software side with the development of the ATLAS program to configure the hardware the ADAS II program to acquire end store the data and the SDAS program to post process analyze and archive the data All of these programs are LabVIEW executables and require no software license or additional software to run RECENT HARDWARE DEVELOPMENTS Several additional hardware features have been added to the PLDS to yield new capabilities since the prototype was deployed on the AOC turbine during the summer of 1998 The GPS receiver is no longer mounted on the PLDS card as a daughter card Instead the receiver is now connected to the PLDS via a 9 wire cable and is mounted in a small sealed enclosure immediately adjacent to the GPS antenna The new configuration is pictured in Figure 2 This reduces the size of the PLDS so that it only requires one slot in the DAS mainframe freeing up room for additional data acquisition modules It also enables the user to mount the antenna for GBUs several hundred feet away from the PLDS with no need to be concerned about attenuation of the GPS antenna signal as was the case with the earlier configuration The RBU anterna must still be mounted on the rotor axis of rotation so it will still be close to the PLDS An analog to digi
20. re allows the user to specify the ATLAS hardware configuration the channels to be sampled the sampling rate and the setup specifics for each channel It then programs the data acquisition units to perform the desired operations The NREL developed ADAS II software enhanced to handle the continuous long term time series data acquired by ATLAS retrieves the acquired data from computer memory displays data as directed by the user stores data to disk and performs a limited amount of user directed analysis in near real time The time series data files generated by ADAS II can be imported directly into several analysis routines such as the NREL developed programs GPP Genstats and Crunch as well as the new SDAS program The SDAS software has been written to help process the large amounts of data that are typically collected in wind energy research SDAS can retrieve a continuous stream of time series files either from ADAS II in pseudo real time or off line from archived time series files It can calculate and store an extensive set of user selected and configured statistics saving the results in a central database for later access SDAS also has a powerful conditions filtering capability that will allow a user to interactively interrogate the database for any set of time series files that was previously processed by SDAS Results can be plotted for easy viewing displayed in Excel spreadsheets or written to new time series files
21. rtinent information that belongs to that specific data file The data and header files can then be read by many software packages for post processing NREL prograrns GPP Crunch and Genstats as well as the new SDAS The Collect Data window shown in Figure 11 is displayed during actual data acquisition Within this window the user also has the capability to view the data in pseudo real time in any of several different chart formats Other important features of the ADAS II software are the triggering routine and the logbook The triggering routine allows the user to specify specific quotas or conditions to their data In other words if the data does not meet the specific requirements the data are not saved For example If the triggering conditions are set to take data when the wind speed is greater than 6m s data will not be saved unless the wind speed exceed 6m s The logbook feature maintains a record of any modifications errors or events that occur while the program is running The user may view this file at any time which can be very useful especially if the program is taking data unattended Figure 11 ADAS II Collect Data Window SDAS SOFTWARE PROGRAM SDAS Overview A new program called the Smart Data Acquisition System SDAS has been written to help researchers process the large amounts of data that are typically acquired in performing wind energy technology research Data acquired and stored with the
22. tal conversion chip has been added to the PLDS board to facilitate measurement of temperatures currents and voltages This enables the user to track the health and status of the card and the new battery power supply We are now utilizing lower power GPS receivers dropping the power consumption from 1 1 watt to 0 2 watts and have implemented a sleep mode to further conserve power when data are not being acquired This would normally be used only in the RBU where a battery pack is used for power In this mode we switch off the power to the DAS mainframe all the DAS modules the modems and selected components of the PLDS module for 50 seconds of every minute The programmable logic device PLD on the PLDS module remains alive and will turn on the telemetry components for the first 10 seconds of each minute to check for communications from the user The RBU remains in this mode until a wake up call is received These features result in a dramatic reduction in power consumption For example the ATLAS RBU on the AOC turbine which provides excitation power to and acquires data from 15 strain gauges now consumes about 32 5 watts of power whenever it is acquiring data or not The new version of the PLDS enables us to place the unit into sleep mode when not actually acquiring data This drops the power consumption to about 2 watts Whenever we are ready to take data we wake the unit up and within five seconds it is consuming 32 5 wa
23. the user through a series of steps to configure and program the ATLAS hardware The first thing the user must do is configure the hardware by selecting the Configure Hardware button from the front panel This brings up the window shown in Figure 4 where he can select the size of the DAS mainframe the number of data acquisition module slots and the different data acquisition modules that are inserted If the hardware configuration contains one or more slave units the user can also specify the mainframe size and modules inserted in those units at this time Once the hardware configuration is complete the user clicks the OK button and is returned to the front panel yf SBS OE A SS Se PTE ORT A RED quir iMicra B TOET Ti jt T Amna niy YAAN ME AA AR Eke 2 UROEN i IOIO a HeT XY BAR MARYN i a ITOT gt LENS ON ETE sui Figure 4 Configure Hardware Window Notice the Setup Slave button on the right The communications protocol to be used by the various DAS units is the next parameter to be specified using the MicroPro Settings button which brings up the window shown in Figure 5 Here the data word size the sync word and the type of data encodinz NRZ L or Bi phase must be specified These settings apply to all DAS units in the ATLAS Whether the mode of data communication is TTL or RS 422 must also be specified and this can vary from DAS to DAS RS 422 can be utilized to tr
24. tion Post Processing View Utilities Options Help menu bar As long as SDAS is running this window will always be on the desktop jem Situs Wank ora LOTTE Figure 12 SDAS Status Window SDAS Statistics SDAS can calculate a large number of built in user selected statistics Along with the minimum and maximum the four moments mean standard deviation skewness and kurtosis can be calculated for each data channel Also up to thirteen special statistics called cross channel statistics can be calculated A cross channel statistic is calculated from more than one data channel and such statistics are routinely calculated in wind energy research The list of cross channel Statistics currently available within SDAS includes capacity factor horizontal sonic direction horizontal sonic velocity Obukhov length Reynolds stress Richardson number total sonic velocity vertical sonic velocity wind direction wind shear yaw error yaw rate and turbulence intensity SDAS Acquisition Configuration Before any data can be acquired SDAS has to know what statistics are to be calculated and stored in the database for each input channel The Statistical Analysis Configuration window shown in Figure 13 allows the user to interactively point to a channel statistic field intersection and select or deselect the statistics to be calculated and stored for any raw data or calculated channel An X indicates the statistic wi
25. tts and acquiring data Figure 2 GPS Antenna and Receiver Enclosure i The PLD logic program has been enhanced to latch the GPS time accurate to one microsecond when the analog and strain gauge data are actually acquired Including this time in the data stream gives the user a powerful tool for determining if and when communication dropouts occur In addition the user can now direct the PLDS to e transmit the GPS data to the GBCU e connect the full duplex communications between the GBCU and the DAS for remote programming of the DAS e transmit the DAS data via serial link to the GBCU e transmit the unique PLDS identification cade to the GBCU reset the PLDS enter or exit the sleep mode turn DAS 12 volt power on or off turn GPS 5 volt power on or off turn the PLDS generated external pulse train generation on or off A prototype battery system permits the installation of an RBU on a rotor that has no electrical power The 15 pound unit consists of nickel metal hydride cells and has a nominal rating of 48 amp hours at 12 VDC The nickel metal hydride cells have twice the energy density of the more common nickel cadmium cells and do not suffer from the memory effect a loss of ability to accept charge and an increase in internal resistance that affects those cells Nickel metal hydride cells can be recharged hundreds of times with little or no degradation and do not require a complex charging unit unlike the high
26. tually locked to GPS time Once this occurs the DAS unit is ready for data acquisition This condition must be true for all DAS units in the ATLAS before data acquisition takes place ADAS II SOFTWARE PROGRAM ADAS II is a modified version of the Advanced Data Acquisition System ADAS software developed by NREL for acquiring data from the ADAS hardware It has been enhanced to acquire and store continuous time series data from the ATLAS hardware This software will run on a computer with the following minimum capabilities e Pentium 200MHz or faster e 64Mb of RAM 128Mb recommended e 25Mb disk space plus necessary disk space for data storage 1024 X 768 minimal resolution Windows 95 or 98 The Front Panel of the ADAS II software is shown in Figure 9 ADAS II accesses the PCM file that was created by the ATLAS software and decodes that file to acquire the information it needs to configure itself to actually acquire data from the ATLAS hardware ADAS I DATA ACQUISITION SYSTEM REVALLIAB Figure 9 ADAS II Software Front Panel The ADAS II Channel Configuration window is shown in Figure 10 Figure 10 ADAS II Channel Configuration Window Once the program has been configured the user must specify the location and the time duration of the data files to be taken and then the software is ready to acquire continuous data All saved data files are stored with a header file which contains all of the pe
27. ty to gracefully handle utility power failures that could affect the integrity of the data acquisition The ADAS and SDAS computers and ATLAS data acquisition hardware are all on an uninterruptible power supply UPS If a power failure occurs the software that controls the UPS generates a text file in a user defined folder on one of the computers If SDAS detects the presence of this text file in the specified folder SDAS will finish all calculations on the current time series file store all calculations in the database record all the user defined SDAS settings and gracefully terminate itself before the SDAS computer is shut down by the UPS Currently the ADAS II software and ADAS computer do not have this power failure shutdown capability When the utility power recovers the SDAS computer is powered on by the UPS self boots and SDAS is restarted SDAS will reverse the shutdown process reestablishing its acquisition configuration and resume time series file acquisitions performing statistical calculations and storing results in the database as if nothing had happened OPERATING EXPERIENCE Two severe lightning strikes on the AOC prevented us from acquiring much data from our prototype installation even though we installed it over a year ago The first strike damaged the ATLAS extensively We added lightning protection to protect most data lines but lack of space in the RBU enclosure forced us to leave it unprotected The se
Download Pdf Manuals