USER`S MANUAL - Mantech Electronics
Contents
1. 20 c it VA Watt 1 2KVA 2 4KVA 3 6KVA i pore 800W 1600W 2400W Backup Time at full load long time available UPS status I P amp O P Voltage Frequency Load Max Charging Current 5 steps selectable Battery Voltage 12Vdc 24Vdc 24Vdc Battery LCD Battery Voltage amp Charge current Temperature Model Normal Green Warning Yellow Fault Red Display LCD Beeping every 4 seconds Battery Mode Low Battery Beeping every second Audible Alarm UPS Fault Beeping Continuously Operation Temperature 0 40 degree C 32 104 degree F Environment Relative Humidity 0 95 non condensing Audible Noise Less than 55dBA at 1M Net Weigh Kgs 12 24 31 50 Physical WxHxD mm Rack Mount 440 132 290 440 132 360 440 132 360 WxHxD mm Wall Mounted 298 400 150 298 450 190 298 450 190 Specifications are subjected to change without prior notice EA Capacity VA Watt 6 6KVA 4000W 10KVA 6000W 13KVA 8000W Capacity 5KVA 4000W 6 6KVA 4000W 10KVA 6000W 13KVA 8000W Homma volage 220Vac 110Vac 220Vac only Battery Voltage 24Vdc 48Vdc Acceptable Voltage Backup Time at full load long time available d H 420 275Vac 60 135Vac 120 275Vac Battery Range Max Charging Current Frequenc 50Hz 60Hz 45Hz 70HZ legals 5 steps Eege ele gt 60A ij 45Hz 70Hz npn Voltage Range panel Low Battery Beeping every second 110Vac 115V or 120VAC re settable via LCD Polk a panel Overloa
2. the LCD Display shall light up immediately to display first the main menu of greeting context and the Normal LED is blinking to indicate ready to switch on the inverter 2 By pressing the Enter key and the Down key simultaneously for 3 seconds the UPS will start up after two beeps and Normal LED lights up to indicate the power is from its inverter to the load 3 When the Down key and the Up key are pressed simultaneously for 3 seconds the inverter will be turned off after two beeps and the UPS is on the standby status LCD display illuminates and Normal LED is blinking until AC source is disconnected 4 LCD Display Menu Battery Status Use Up Down key to select menu displays of the LCD described below This screen will refresh once the system power is enabled Rated Spec Status AC FAIL BAT OR LINE MODE Bakmi a eT Cen eee INSIDE TEMP 33 C BIR OUTPUT VOLTAGE 220 Wac or on ER mwasi emeu FAULT WARNING MORMAL D E ainia s r SYSTEM TESTI MUTE el st a NEW AC FAIL 0 OLD AC FAIL 0 Frequency Re a d b REC OVERLOAD 0 Ss 12 13 Output Voltage amp Frequency Adjust Ce Charging Current Adjust A In this screen press Enter key to see A In this screen press enter the following steps for Enter key to enter the output voltage and frequency following steps for genera
3. UPS Pure Sinewave Inverter USER S MANUAL 1 2K 2 4K 3 6KVA 6 6K 10K 13KVA WELCOME TO USE HOME UPS A 4 V A IMAT wafa gel zz AA A d N 1 D D if U SOLLST Ti u i NE y CONTENTS 1 INTRODUCTION onssssssssssssssssssnssssrnnrsnsrrrsssrrnrrerrrnnnrrrrresen 1 2 SAFETY INSTRUCTION eee eee eee ee eeeeeeees 2 3 CABLE CONNEC TION eee eeee eee ee eeeeeeeeees 4 BOO WEI SARL DEE 5 SURT e RATION EE 11 6 TROUBLE SHOOTING GUIDE errre 16 7 OPERATION MODES OF THE UPS saanane 18 8 SPECIFICATION OF UR 20 1 INTRODUCTION 1 1 General Description This UPS a powerful all in one solution delivers unsurpassed clean true sine wave output power and combines this with a selectable multistage battery charging current Applicable for any kind of loads such as air conditioner home appliances consumer electronic and office equipments This series features a durable amp continuous 24 operation The built in 5 stage intelligent charger automatically charges any type of batteries without the risk of overcharge The compact amp modular design makes utility interactive installations easier and more cost effective It is a high quality product that offers the best price performance ratio in the industry 1 2 Key features Multiple microprocessor design base Compatible with both linear amp non linear load Stronger charger to support batteries of 500AH up 24 hours operation on the inverter DC start and a
4. Y 7 2 Normal Operation There are two main loops when AC utility is normal the AC loop and the battery charging loop The AC output power comes from AC utility input and passes through static switch to support power to load The battery charging voltage comes from AC utility input and converted by AC DC charger to support battery charging power 7 AC OUTPUT AC INPUT eTATIC DC AC SWITCH INVERTER N F AC DC CHARGER BATTERY 18 7 3 AC Utility Failure Battery Mode The AC output comes from battery passing through DC AC inverter and static switch within the battery backup time AC OUTPUT AC INPUT STATIC DC AC SWITCH INVERTER N F AC DC CHARGER BATTERY 19 8 SPECIFICATION OF UPS Canacit TETRAN 1 2KVA 2 4KVA 3 6KVA Ge 800W 1600W 2400W 120 275Vac 60 135Vac Nominal Voltage Acceptable Voltage Range niput Voltage Line Low Transfer 120VAC 2 60VAC 2 Range Line Low Return 130VAC 2 65VAC t 2 Line High Transfer 275VAC 2 135VAC 2 Line High Return 260VAC 2 130VAC 2 220Vac 230V or 240VAC re settable via LCD panel Voltage 9 110Vac 115V or 120VAC re settable via LCD panel Voltage Regulation Batt Mode E requency Regulation 0 1Hz Batt Mode lt 3 RMS for entire battery voltage range Line Mode Circuit Breaker Overload eech Battery Mode 110 150 for 30 sec gt 150 for 200ms Transfer Time Typical lt 8 ms
5. d Beeping twice per second 50Hz or 60Hz Voltage Regulation 3 RMS for entire battery voltage range Batt Mode Operation Temperature 0 40 degree C 32 104 degree F Frequency Regulation 0 1Hz Environment Relative Humidity 0 95 non dondensing Audible Noise Less than 55dBA at 1M Power Factor Net Weigh Kgs 49 2Kg 51 4Kg 55Kg Waveform Pure Sinewave Physical Line Low Transfer 120VAC 2 60VAC 2 120VAC 2 UPS status I P amp O P Voltage Frequency Load Line Low Return 130VAC 2 65VAC 2 130VAC 2 Display LCD SE DEES See SECHER ode Line High Transfer 275VAC 2 135VAC 2 275VAC 2 LED Normal Green Warning Yellow Fault Red Voltage Line High Return 260VAC 2 130VAC 2 260VAC 2 Battery Mode Beeping every 4 seconds 220Vac 230V or 240VAC re settable via LCD Audible Alarm Frequency WxHxD mm Wall Mounted 415 600 260 415 600 260 415 600 260 Effiecincy GH S Specifications are subjected to change without prior notice Gerten EEN Battery Mode 110 150 for 30 sec gt 150 for 200ms 22 23
6. em 2 4 Operation 1 Do not disconnect the mains cable on the UPS system or the building wiring socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads 2 The UPS has its own internal power source batteries The output terminals may be live even when the UPS is not connected to the AC supply 3 Ensure that no fluids or other foreign objects can enter the UPS system 1 2 5 Maintenance and Service Caution risk of electric shock Even after the unit is disconnected from the mains power supply building wiring socket outlet components inside the UPS system are still connected to the battery and are still electrically live and dangerous Before carrying out any kind of servicing and or maintenance disconnect the batteries and verify that no current is present 2 Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries remove wristwatches rings and other metal objects use only tools with insulated grips and handles 3 CABLE CONNECTION 3 1 Inspection 1 The system may be installed and wired only by qualified electricians in accordance with applicable safety regulations 2 When installing the electrical wiring please note the nominal amperage of your incoming feeder 3 Inspect the packaging carton and its contents for dama
7. ge Please inform the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use 4 Please ensure that the incoming feeder is isolated and secured to prevent it from being switched back on again 3 2 Connection 1 UPS Input Connection If the UPS is connected via the power cord please use a proper socket with protection against electric current and pay attention to the capacity of the socket 2 UPS Output Connection The output of this model is with socket types only NEMA or IEC Simply plug the load power cord to the output sockets to complete connection 4 SYSTEM DESCRIPTION 4 1 Front Panel Description 6 7 FAULT WARNING pc SYSTEM TEST MUTE 2 3 4 1 LCD Display This indicates the UPS operation information including UPS status input output voltage input output frequency battery voltage battery capacity left output load inside temperature and the times of history events 2 Up key Use to select upward the UPS status on LCD Display 3 Down key Use to select downward the UPS status on LCD Display Beside press it simultaneously with the Up key to switch off the UPS 4 Enter Key It is pressed with the Down key to turn on the UPS In battery operation mode press it with Up key at the same time to disable the buzzer Beside it is pressed to confirm and enter the item selected 5 Fault LED red To indicate t
8. he UPS is in fault condition because of inverter shutdown or over temperature 6 Warning LED yellow To indicate the UPS is in the status of overload bypass and battery back up 7 Normal LED green To indicate the UPS is operating normally 8 ON TEST MUTE key It should be pressed with the control key simultaneously to switch on UPS do UPS auto test in normal AC mode and turn off the buzzer in battery operation 4 1 Outline Description 1 1 2KVA Wall Mounted Type W 298mm 2 2 4KVA 3 6KVA Wall Mounted Type WW 298mm DAI TEAT a BATTERY i SC MOTE GONT 6 6KVA 10KVA 13KVA Wall Mounted Type eres iW oe mme i EI sen R D 260mm A H 600mm oco IN TELLIGET SOLT REMOTE CONTROL SOL AR BOL SS 10 5 UPS OPERATION 5 1 Check Prior to Start Up 1 Ensure the UPS is in a suitable positioning 2 Check input cord is secured 3 Make sure the load is disconnected or in the OFF position 4 Check if input voltage meets the UPS rating required 5 2 Storage Instruction Disconnect input power in rear panel if you will not use it for long period If the UPS is stored over 3 months please keep supplying power to the UPS for at least 24 hours to ensure battery fully recharged 5 3 Operation Procedure for LCD Model Please follow the instructions below for UPS operation WE LC OME 2 USE HOME UPS 1 Once the AC source is connected
9. l adjustment battery AH adjustment B The cursor will pop up to indicate the output voltage and B The cursor LA will pop up VOLT FREQ SET i 220Vae S0H4 PEEP s to indicate the battery AH pr i newly selected C Use Up or Down key to adjust e AEEA aam l al Ce Ga the output voltage if 220V a ae c Se t 2 Use Up or Down key to d e Wee WAT a U configure 220V 230V and 240V Di W E Sy frequency newly selected select the battery AH 100AH 200AH 300AH SS 400AH and 600AH selectable Press is selectable if 110V configure 110V 115V and 120V is selectable Press Enter key to a confirm voltage and then the Sg j gier SOHZ Enter key to confirm your cursor will move to frequenc d L mu battery AH selection The output frequency j 50Hz or 60Hz can be adjusted Kall COI Ca l SE E D Once the correct battery AH by the same key operation ee is selected press Enter key again to save the selection D Once the correct voltage is selected press Enter key again to save the selection 14 19 6 TROUBLE SHOOTING GUIDE 6 1 For LCD Model The following guideline may be helpful for basic problem solving No UPS STATUS POSSIBLE CAUSE ACTION UPS STATUS POSSIBLE CAUSE ACTION AC utility power AC utility power 1 Reduce the less fails The load is failure critical load in AC utility power is normal UPS is running nor
10. mally but fault LED lits up Buzzer beeps continuously AC utility power is normal but UPS is overloaded Warning LED lits up and buzzer beeps per second AC utility power is normal Warning LED does not fade out and buzzer beeps per 0 5 second AC utility power is normal Warning LED lits up and buzzer beeps continuously 1 Charger PCB is damaged 2 Fan is damaged 3 Unknown Overload 100 lt load lt 125 Overload 125 lt load lt 150 Overload 150 lt load 16 1 Replace the charger PCB 2 Replace the fan 3 Restart UPS Please reduce the critical load to lt 1 00 Please reduce the critical load to lt 1 00 Please reduce the critical load to lt 1 00 supplied by battery power Buzzer alarm sounds every 4 seconds AC utility fails UPS is in battery backup mode Buzzer alarm beeps every second AC utility power fails UPS has shut down automatically AC input connection may be not correct Battery power is approaching low level Battery runs out order to extend backup time 2 Please check the rated input or connected line UPS will shut down automatically Please save data or turn off the loads soon UPS will restart up when AC utility power is restored 7 OPERATION MODES OF THE UPS 7 1 UPS System Block Diagram AC INPUT STATIC DC AC SWITCH INVERTER N F AC DC CHARGER BATTER
11. utomatic self diagnostic function THD less than 3 High efficiency design to save electricity Low heat dissipation in long time operation Oo ON OO A W N Design to operate under harsh environment 10 3U 19 Rack Mount or WALL Mounted design 1 3 Important Notices 1 Read instructions carefully before operating the UPS 2 UPS power connect instruction should be followed 3 Please dont open the case to prevent danger 5 Retain the load within the rating of UPS to prevent faults 6 Keep the UPS clean and dry 2 SAFETY INSTRUCTION 2 1 Transporting 1 Disconnect all power cables if necessary 2 Be careful not to damage the UPS while transporting 3 Don t move the UPS upside down 4 Please transport the UPS system only in the original packaging to protect against shock and impact 2 2 Positioning 1 Do not put the UPS on rugged or declined surface 2 Do not install the UPS system near water or in damp environments 3 Do not install the UPS system where it would be exposed to direct sunlight or near heat 4 Do not block off ventilation openings in the UPS system s housing and don t leave objects on the top of the UPS 5 Keep the UPS far away from heat emitting sources 6 Do not expose it to corrosive gas 7 Ambient temperature 0C 40 C 2 3 Installation 1 Connect the UPS system only to an earthed shockproof socket outlet 2 Place cables in such a way that no one can step on or trip over th