6-port 10/100TX + 2-port 100FX SNMP Managed Industrial Ethernet
Contents
1. IP configuration interface 39 SNTP Configuration User can configure the SNTP Simple Network Time Protocol settings The SNTP allows user to synchronize switch clocks in the Internet R SNTP Client To enable or disable SNTP function to get the time from the SNTP server B Daylight Saving Time To enable or disable daylight saving time function When daylight saving time is enabling user need to configure the daylight saving time period R UTC Timezone Set the switch location time zone The following table lists the different location time zone for the reference User also can drag down the list to find the time zone user want it Local Time Zone Conversion from UTC Time at 12 00 UTC November Time 1 hour 11am Zone Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight AST Atlantic Standard EDT Eastern Daylight EST Eastern Standard CDT Central Daylight CST Central Standard MDT Mountain Daylight MST Mountain Standard 3 hours 9 am 4 hours 8 am 5 hours 7 am 6 hours 6 am 7 hours 5 am 40 PDT Pacific Daylight PST Pacific Standard ADT Alaskan Daylight 8 hours 4am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SW
2. NX 8BO2N Front Panel of the industrial switch Reset Button The reset button provides user a quick and easy way to restart and set the configuration back to default value R Restart press the button for 2 seconds and release R Set to factory default value press the button for 5 seconds and release The switch will set all configurations back to default setting Bottom View The bottom panel of the 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring has one terminal block connector within two DC power inputs and one DC IN power jack LO 00 0000000 0000 oogoooo0o0o0o0o0oo00000ngo G G 9 Gr 000000 0000 PWR2 1A 24V PWR1 Power Input DC 24 12 V 48V Pid YZ VZ Le Vi VI V Fault pg Bottom Panel of the industrial switch DIP switch The switch provides the 9 DIP switch for configuring the relay alarm operation mode and the master ring operation mode The default value of Dipswitch is OFF DIP Switch No Status OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Description Disable port 1 Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port
3. SNMP Configuration The SNMP is a Protocol that governs the transfer of information between management and agent The switch supports SNMP V1 User can define management stations as trap managers and to enter SNMP community strings User also can define a name location and contact person for the switch Fill in the system options data and then click Apply to update the changes SNMP Configuration System Options Name Location Contact Apply Help Community Strings Current Strings New Community String public RO Add String private __ RV Remove RO CRW Trap Managers Current Managers New Manager none Add IP Address Remove V LO Trap version y1 y2c 54 SNMP Management interface System Options RB Name Enter a name for the switch B Location Enter the switch physical location B Contact Enter the name of contact person or organization Community strings Serve as a password RB Strings Key in the name of string m RO Read only Enables requests accompanied by this string to display MIB object information m RW Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects R And then click Add Trap Manager A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the
4. aaZeon 6 port 10 100TX 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring User Manual aaZeon AAXEON TECHNOLOGIES WWW aaxeon com FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver B Connect the equipment into an outlet on a circuit different from that to which the receiver is connected B Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content d dee Ted EE 1 E
5. Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up NOTE 1 When port alarm function is enabled the fault LED will on and Alarm OFF Disable port Alarm Enable port Alarm If the port s link fails the fault LED will light up Disable the ring master function Enable the switch as the ring master in the Redundant Ring group relay will activity when port failure occurs 2 Please restart the switch after the Redundant Ring DIP switch is set LED Indicators There are 7 diagnostic LEDs located on the front panel of the industrial switch They provide real time information of system and optional status The following table provides description of the LED status and their meanings for the switch LED Power Power 1 Power 2 Green Off Green Off Green Off Meaning The switch unit is power on The switch unit is no power input Power on No power inputs Power on No power inputs Power failure or UTP port failure or Yellow Fiber port failure Fault Ort No Power failure or UTP port failure or Fiber port failure occurs The
6. Multi mode 30KM single mode Wavelength 1310nm multi mode single mode 1 6Gbps 1 19Mpps 64bytes 12 48 VDC Redundant power with polarity reverse protects function and connective removable terminal block for master and slave power 6 Watts 2 ports for Redundant Ring to provide redundant backup feature and the recovery time below 300ms and start by Web interface management The ring port can be defined by Web interface Port based VLAN IEEE802 1Q Tag VLAN Both of port based and Tag based VLAN group up to 64 VLANs 66 Class of service Quality of service Spanning tree IGMP SMTP SNTP Management IP security Port mirror Firmware update Alarm IEEE802 1p class of service Per port provides 4 priority queues The quality of service determined by port Tag and lpv4 Type of service IEEE802 1d spanning tree IEEE802 1w rapid spanning tree IGMP v1 and Query mode Up to 256 groups Simple mail transfer protocol Simple Network time protocol IP address security to prevents unauthorized intruder TX packet only Both of TX and RX packet TFTP firmware update TFTP backup and restore One relay output for port breakdown and power fail Dipswitch to mask link down port Alarm Relay current carry ability 1A DC24V 67 Bandwidth control DHCP client Install Operation Temperature Standard Model Operation Temper
7. fails the system will produce a log message Redundant Ring topology change When the Redundant Ring topology has changed the system will produce a log message Port event selection Select the per port events Per port have 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event is selected gt Link UP The system will produce a log message when port connection is up only Link Down The system will produce a log message when port connection is down only Link UP amp Link Down The system will produce a log message when port connection is up and down After selected click Apply System Lo System Log Configuration System event selection Cl Device cold start CISNMP Authentication Failure Port event selection Disable Dess Disable v Event Configuration L Power status C X ring topology change Disable v Event Configuration interface 62 Troubles shooting m Verify that is using the right power cord adapter DC 12 48V please don t use the power adapter with DC output bigger than 48V or it will burn this converter down R Select the proper UTP cable to construct user network Please check that is using the right cable use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections or 100Q Category 5 cable for 100Mb
8. like MIB RFC 1215 Trap MIB Private MIB for switch information Redundant SNMP MIB Ring port alarm TFTP firmware upgrade reset port mirror IP security management IGMP management MIB 64 Up to 3 Trap stations Cold start Port link Up Port link down SE Authentication Failure Private Trap for power status Port Alarm configuration Fault alarm Redundant Ring Technology Store and forward switching architecture 14 880 pps for 10Base T Ethernet port Transfer Rate 148 800 pps for 100Base TX FX Fast Ethernet port Transfer packet 64bytes to 1522 bytes with VLAN tag size 4 types of packet filter rule with different packet combination B AIl of packet Packet filter B Broadcast multicast unknown unicast packet B Broadcast multicast packet Broadcast packet only MAC address 2K MAC address table Memory Buffer 1Mbits Per port Link Activity Green Full duplex Collision Yellow LED Per unit Power Green Power 1 Green Power 2 Green Fault Yellow Master Green 65 Network Cable Optical cable Back plane Packet throughput ability Power Supply Power consumption Redundant Ring VLAN 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m SC Multi mode 50 125um or 62 5 125um SC Single mode 9 125um or 10 125um Available distance 2KM
9. networks Traffic through ports can be monitored by one specific port That is traffic 27 goes in or out monitored ports will be duplicated into mirror port B Port Mirroring Mode Set mirror mode Disable TX and Both The default value is Disable R Analysis Port It means mirror port can be used to see all monitor port traffic User can connect mirror port to LAN analyzer or Netxray R Monitor Port The ports user wants to monitor All monitor port traffic will be copied to mirror port User can select max 7 monitor ports in the switch User can choose which port that wants to monitor in only one mirror mode Mark the State check box to select the port R And then click Apply Port Mirroring Port Mirroring Mode Disable Apply Help Prot Mirroring interface NOTE 1 Select the monitor mode as disable to disable the mirroring 2 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 28 VLAN configuration A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physicall
10. 200000000 R Priority Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 R Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it 46 is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling R Admin Edge The port directly connected to end stations cannot create bridging loop in the network To configure the port as an edge port set the port to True status RB Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation R And then click Apply button NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off Rapid Spanning Tree System Configuration Per Port Configuration priority must be a multiple of 16 Apply Help RSTP Port Status Port 01 200000 Port 02 200000 Port 03 200000 Part 041200000 Port 05 200000 Port o6 200000 Port 07 200000 Port og 200000 RSTP Per Port Configuration interface 47 Redundan
11. A Symmetric Port 05 100TX 100 Full 100 Full Port 06 100TX 100 Full Port OS 100FX Down Enable Force 100 Full Hi Asymmetric Port Status interface Single Port Information Click the port on the Panel figure on the web interface directly Then the single port information window will show up and display the port current information 24 3 http 192 168 16 1 Port 5 Status ll e I ess E Port information interface Port Statistics The following information provides the current port statistic information R Click Clear button to clean all counts Port Statistics ra lars unk ee EE Port 01 100Tx Downenable 0 O O oO ao oO Port 02 100Tx DownEnable o o o Oo o 0o Port 03 100Tx Downenable o o o o o o0 Port 04 100Tx Downenable o o o o o o Fort long Up Enable 12736 o 28043 o o o Port 06 100Tx Downenable o o o oO o 0o Port 07 100Fx DownEnable o o o o o o0 Port 0s 100Fx Downenable o o o o o o Clear Help Port Statistics Interface 25 Port Control Change the port status R Select the port by scroll the Port column B State Disable or enable control of this port RB Negotiation Set auto negotiation mode is Auto Nway specify the speed duplex on this port and enable auto negotiation or Force Speed Set the speed of the port Duplex Set full duplex or half duplex mode of the port Flo
12. Alarm Relay output for system events Support Redundant Ring function Power polarity reverse protect 1Mbits Embedded memory Support Port based VLAN 802 1 Q Tag VLAN IEEE 802 1p class of service and provide port base Tag base and Type of service priority method Support DHCP client SNMP Web Management RMON supported TFTP firmware update and system configure restore and backup Package Contents Please refer to the package content list below to verify them against the checklist 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch w Redundant Ring 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring One DIN Rail attached on the switch One wall mount plate and six screws User manual LA ANY Wall Mount Plate Screws DIN Rail Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation Physical Dimension 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring dimension W x H x D is 54mm x 135mm x 105mm Front Panel The Front Panel of the 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring is showed as below
13. Alert Configuration When the specific events occur the system will send the alert to the email account that is assigned by user User can set up the mail server IP mail 35 account and forwarded email account for receiving the event alert Email Alert To enable or disable the email alert function SMTP Server IP Address Set up the mail server IP address Authentication Mark the check box to enable and configure the email account and password for authentication gt Mail Account Set up the email account to receive the alert Ex johnadmin 123 com The email account must exist on the mail server which user had set up in SMTP Server IP Address column gt Password The email account password gt Confirm Password Re confirm the password RB E mail Address of Receipient 1 4 Assign up to 4 e mail accounts also to receive the alert m And then click Apply Email Alert Configuration Event Configuration Power Alarm Configuration E mail Alert Disable v Email Alert Configuration interface 36 Event Configuration The selected events that occur will send out the alert to the assigned SMTP server Also user can select port events for alerting RB System event selection 4 selections Device cold start Power status SNMP Authentication Failure and Redundant Ring topology changes Mark the checkbox to select the event When selected events occur the system will sent out the alerting gt Dev
14. For example user set the TOS level 25 is high The port 1 is following the TOS priority policy only When the packet received by port 1 the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority 50 NOTE QoS and Rate control cannot be existed at the same time Qos Policy Use an 8 4 2 1 weighted fair queuing scheme C Use a strict priority scheme Priority Type Port based lt ort based ee es E ary eae eee Por bel Default Port Priority Port 01 Port 02 Port 04 Port 05 Port 06 Lowest ER IS z Jose x Lowest Dose zl Jose z 2 eet na cos eet TOS Lowest el Lowest e i Sr ag a S Si J flowers lowers overs E eo on EE Lowest Lowest 2 Lowest Lowest Z rk a QoS configuration Interface 51 IGMP The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message as follows Message Description A message sent from the querier IGMP router or Query switch asking for a response fro
15. IP address of the station and a community string B P Address Key in the trap device IP RB Community Strings The trap device community strings R And then click Add Configuration Backup 55 In Configuration Backup user can restore the backup configuration into the industrial switch Also user can backup the configuration to TFTP server TFTP Restore Configuration User can restore flash ROM value from TFTP server but user must put the backup image in TFTP server industrial switch will download the image back to the flash B TFTP Server IP Address Key in the TFTP server IP B Restore File Name Key in the restore file image name R And then click Apply Configuration Backup TFTP Restore Configuration TETP Backup Configuration 0 0 0 0 Jost det Apply Help TFTP Restore Configuration interface TFTP Backup Configuration User can save current flash ROM value from the industrial switch to the TFTP server then go to the TFTP restore configuration page to restore the image value back to the industrial switch B TFTP Server IP Address Key in the TFTP server IP B Backup File Name Key in the file image name R And then click Apply 56 Configuration Backup TETP Restore Configuration TFTP Backup Configuration 0 0 0 0 Jost det Apply Help TFTP Backup Configuration interface TFTP Update Firmware It provides the functions to allow a user to update the switch firmware Before u
16. T Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 ZP5 USSR Zone 4 4 hours 5 hours 4pm 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard CCT China Coast USSR Zone 7 7 hours 8 hours 7pm 8 pm 41 JST Japan Standard USSR 9 hours 9pm Zone 8 EAST East Australian Standard GST 10 hours 10 pm Guam Standard USSR Zone 9 IDLE International Date Line NZST New 12 hours Midnight Zealand Standard NZT New Zealand SNTP Sever IP Set the SNTP server IP address Switch Timer Display the switch current time Daylight Saving Period Set up the Daylight Saving beginning and ending time Daylight Saving beginning and ending time will be different in every year B Daylight Saving Offset mins Configure the offset value R And then click Apply button NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 42 SNIP Configuration SNTP Client Disable DI Daylight Saving Time Disable D GMT Greenwich Mean Time Dublin Edinburgh Lisbon London D 0 0 0 0 20040101 00 00 20040101 00 00 es anes Ss Apply Help SNTP Configuration IP Security IP security function allows user to assign 10 specific IP
17. addresses that have permission to access the switch through the web browser for the securing switch management B Enable the IP Security Mark the check box to enable the IP security function R Security IP 1 10 Assign up to 10 specific IP address Only these 10 IP address can access and manage the switch through the Web browser R And then click Apply button to apply the configuration NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 43 IP Security IT Enable IP Security Apply Help IP Security Interface RSTP Configuration The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol System Configuration m User can view spanning tree information about the Root Bridge m User can modify RSTP state After modification click Apply button gt RSTP mode user must enable or disable RSTP function before configure the related parameters gt Priority 0 61440 a value used to identify the root bridge The bridge with the lowest value has the highest priority and is 44 selected as the root If the value changes user must reboot the switch The value must be multiple of 4096 according to the protocol standard
18. ature Extended Model Operation Humidity Storage Temperature Case Dimension Ingress packets filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 128kbps 256Kbps 512Kbps 1MB 2MB 4MB and 8MB Ingress filter packet type combination rule for Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The ingress packet filter rate can be set follow as 1Mbps 2Mbps 4Mbps 8Mbps 16Mbps 32Mbps 64Mbps DHCP client function to obtain IP address from DHCP serve DIN rail kit and wall mount ear for wall mount or DIN type cabinet install 10 C to 70 C 14 F to 158 F 40 C to 80 C 40 F to 176 F 5 to 95 Non condensing 40 C to 85 C IP 30 54 mm W x 135 mm H x 105mm D 68 EMI Safety Stability testing FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 UL cUL CE EN60950 IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration 69
19. ble The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD Ol O N Transmit Data minus TD Receive Data minus RD Switch Router or PC 3 TD 3 RD 6 TD r6 1 RD a RD TD 2 RD 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic E Fiber Port There are two 100Base FX ports The fiber port is SC type connector in multi mode 2Km or single mode 30Km When user connect the fiber port to another fiber port please follow the below figure to connect it Wrong connection will cause the port cannot work normally SC Connector Cable Wiring SC to SC Tx A A Rx Tx Bez B Rx the Laser LED Beam ATTENTION ATTENTION This is a Class 1 Laser LED product Don t stare into 10 Cabling m Using four twisted pair Category 5 cabling for RJ 45 port connection The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long m Fiber segment using single mode connector type must use 8 125 or 9 125 um single mode fiber cable User can connect two devices i
20. d one of VLAN group ID is equal to the assigned Management VLAN ID it still has the right to remote management the switch RB Group Name Assign a name for the new VLAN m VLAN ID Key in a VLAN ID 2 4094 The default is 1 R Grouping the ports and click Add button VLAN Configuration VLAN Operation Mode 802 1Q x T Management vian ID fo Apply Basic Port LAN ID Group Name VLAN ID j Add Remove Next Help 802 1q VLAN Add interface R And then click Next then follow interface as below 33 VLAN Configuration VLAN Operation Mode 802 1Q DI IT Management van ID Ju Apply C Ce Port OI Untag DI Port 02 Untag DI Apply Click Apply to set the outgoing frames are VLAN Tagged frames or untagged gt Tag Outgoing frames with VLAN Tagged gt Untag Outgoing frames without VLAN Tagged Port VID Configure port VID settings Port VLAN ID Enter the port VLAN ID And then click Apply To reset back to default value click Default button 34 VLAN Configuration VLAN Operation Mode 802 10 DI IT Management van ID fo Apply Basic Port LAN ID Apply Help Port 01 802 1q VLAN Port VLAN ID interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off Alert There are three kinds of alert e mail event and power alarm for user to configure Email
21. eer a 1 Package Contents nornas a E sie 2 Hardware DeSCription cccccceceeeceeeeteneeeeeeeeeeeeeeees 4 Physical Dimension sees eee eee eee 4 Pront PANEL sisiane irene aan ar i 4 Reset STH ea EE 5 Gen el 5 DIP SWIG E 5 Ree ere 7 POMS 4 ieee hal O 8 EE e 11 Wiring the Power Inputs see ee eee eee eee 12 Wiring the Fault Alarm Contact see eee eee e e 12 Wiring the Fault Alarm Contact AA 13 Mounting Installation cccccsssssssseeeseesseeseeeneeeees 14 DIN Hal Mounting ss sees sese ee eee eee 14 Wall Mount Plate Mounting sese sese eee eee 16 Hardware Installation ssssssssesesssssssssssses veces se sss sss 17 Network Application ccccceeeeeeeeeeseeeeeeeneeeeenees 19 Redundant Ring Applcaton sse 19 Coupling Ring Application cccccceccceeeeeeeeeeeees 20 Dual Homing Application sese sese eee 21 Web Based Management s sseseeeeeeeeeesenees 22 About Web Based Management 22 Preparing for Web Management 22 SYVSleM EIER 23 PONG E 23 POM EE Ee 24 PONE SIAUSUCS E 25 PON eae leioan ar 26 SWITCH SENG essin ra 26 POM MITONG eech 27 VLAN COMPQUTATION nien e oe 29 AlE SE 35 SNTP Configuration een 40 HEEN eer Ee 43 RSTP Coniig rati n deeg 44 Redundant RING WE 48 Q0S Config ratio EE 50 GMP T 52 Security Manager 53 SNMP Contouraton 54 Configuration Backup 55 TFTP Update Firmware 57 Facto E RU L A tae stasis 57 System ee EE 58 Save Confogurati
22. f the switch and then Press Enter The login screen will appear right after a ee Ze Key in the user name and password The default user name and password as admin 5 Press Enter or OK and then the home screen of the Web Based I Function Menu Bar sar eee a RAT ee ir es i et I management appears as below Welcome to the 6 10 100TX 2 100FX industrial switch 23 Port status View every port status that depended on user s setting and the negotiation result R Port The port number R Type The speed mode ex 100TX 100Mbps R Link Down means No Link UP is for Link m State Display port statuses disable or enable Unlink will be treated as off m Negotiation Display the auto negotiation mode auto force Config means the value that user configured Actual means the current value of the port R Speed Duplex Display port connection speed Config means the value that user configured Actual means the current value of the port R Flow Control Display the flow control status is enable or disable in full mode Config means the value that user configured Actual is for the current value of the port Port Status fe en rier Port o2 100Tx Down Enable Auto 100 Full Auto 100 Full port 03 100TX Enable 100 Full Symmetric Port 04 100TX Down Enable Auto 100 Full NI
23. ice cold start When the device executes cold start action the system will send out the alert to the dedicate SMTP server Power status When the device power status has changed the system will send out the alert to the dedicate SMTP server SMNP Authentication Failure When the SNMP authentication fail the system will send out the alert to the dedicate SMTP server Redundant Ring topology change When the Redundant Ring topology has changed the system will send out the alert to dedicate SMTP server m Port event selection Select the per port events Per port has 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event is selected gt Link UP The system will send out an alert when port connection is up only Link Down The system will send out an alert message when port connection is down only Link UP amp Link Down The system will send out an alert message when port connection is up and down m After selected click Apply 37 Alert Email Alert Configuration Event Configuration Power Alarm Configuration System event selection Device cold start Power status SNMP Authentication Failure x ring topology change Port event selection Event Configuration interface Power Alarm Configuration Power alarm function enables the Relay alarm action Without enabling power alarm function the Relay alarm action will not work even the Relay alarm is set m Mark the check box and click Ap
24. ides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is as below 100Base TX Ethernet Cat3 5 UTP STP cable Data collect server ae serres LZ Weem me Enterprise Switch Industrial Industrial Industrial Switch Switch Field Management Distribute UO 100Base TX Ethernet Programmable Cat3 5 UTP STP cable ES Nits WENNER ENEE Serial Device Server Field Automatic device Field Automatic device Field Automatic device control system logic controller Redundant Ring Application The industrial switch supports the Redundant Ring protocol that can help the network system to recovery from network connection failure within 300ms or less and make the network system more reliable The Redundant Ring algorithm is like as spanning tree protocol STP algorithm but it has faster recovery time than STP The following figure is a sample Redundant Ring application 19 100Base TX Ethernet Cat3 5 UTP STP cable Data collect server Human Management Interface ees Teen Enterprise Switch Industrial Switch Industrial Industrial Switch Switch Backup iat Redundant Ring Group Field Management Programmable logic controller 100Base TX Ethernet Cat3 5 UTP STP cable Distribute UO control system Serial Device Se
25. industrial switch is the master of Redundant Ring group R M Ring Master The industrial switch is not a ring master in Redundant Ring group The port is linking LNK ACT The port is transmitting or receiving S Blinks Fiber port packets from the TX device No device attached The port is operating in full duplex Yellow mode FDX COL Fiber Port Collision of Packets occurs in the Blinks port The port in half duplex mode or no device attached Ports B RJ 45 ports There are 6x 10 100Mbps auto sensing ports for 10Base T or 100Base TX devices connection The UTP ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic B RdJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx NOTE and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the ca
26. llation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Rear Panel of the switch 1 Use the screws to screw the DIN Rail on the industrial switch 2 To remove the DIN Rail reverse the step 1 1 First insert the top of DIN Rail into the track LB Z E 2 Then lightly push the DIN Hat into the track Il 3 Check the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall To remove the wall mount plate reverse steps above 16 Hardware Installation In this paragraph we will describe how to install the 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring and the installation points to be attended to it Installation Steps 1 Unpacking the Indu
27. lticast packet and broadcast packet only The broadcast multicast unknown unicast packet broadcast multicast packet and broadcast packet only are only for ingress packet The egress rate only supports all type packets R Band Width The porti port 8 supports port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate as 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate gt Ingress Select the port effective ingress rate The valid range options are 128kbps 256Kbps 512Kbps 1MB 2MB 4MB and 8MB The default value is disable gt Egress for all Select the port effective egress rate The valid range options are 128kbps 256Kbps 512Kbps 1MB 2MB 4MB and 8MB The default value is disable R And nen click Apply button to apply the configuration 59 Rate Control BroadcastMulticastUnknown Unicast w BroadcastMulticastUnknown Unicast w BroadcastMulticasttUnknown Unicast w BroadcastMulticastUnknown Unicast v BroadcastMulticastUnknown Unicast v BroadcastMulticastUnknown Unicast zi BroadcastMulticastUnknown Unicast w BroadcastMulticastUnknown Unicast w Rate Control Interface NOTE 1 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 2 Qos and Rate control ca
28. m each host belonging to the multicast group A message sent by a host to the querier to indicate Report that the host wants to be or is a member of a given group indicated in the report message A message sent by a host to the querier to indicate Leave Group that the host has quit to be a member of a specific multicast group User can enable IGMP protocol and IGMP Query function in here User will see the IGMP snooping information in this section difference multicast group VID and member port and IP multicast addresses range from 224 0 0 0 through 239 255 255 255 52 IGMP IP Address VLAN ID Member Port 235 080 068 083 IGMP Protocol Enable D IGMP Query Enable DI Apply Help IGMP Snooping interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off Security Manager Change web management login user name and password for the management security issue 1 User name Key in the new user name The default is admin Password Key in the new password The default is admin 2 3 Confirm password Re type the new password 4 And then click Apply Security Manager User Name admin New Password essee Confirm Password eesse Aoo Hele Security Manager interface 53 NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off
29. n the distance up to 30 Kilometers m Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances Wiring the Power Inputs Please follow below steps to insert the power wire V V V V 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose NOTE The wire range of terminal block is from 12 24 AWG Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows By inserting the wires and set the DIP switch at ON status it will detect the fault status which the power is failure or port link failure and form a closed circuit And application example for the fault alarm contact as below Insert the wires into the fault alarm contact NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Fault Alarm Contact The closed circuit will form when the power failure or port link failure l l 24V DC Buzzer 24V Battery The fault alarm device will send a l warning signal to warn the user ex l alarm sound or flash light l Mounting Insta
30. ng B Switch Switch Industrial C Switch Bi bee ring bee link Industrial Industrial Switch Switch 21 Web Based Management This section introduces the configuration and functions of the Web Based management About Web Based Management On CPU board of the switch there is an embedded HTML web site residing in flash memory which offers advanced management features and allow users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 5 0 And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen NOTE By default IE5 0 or later version does not allow Java Applets to activate sockets In fact the user has to explicitly modify the browser setting to enable Java Applets to operate network ports Preparing for Web Management Before to use web management install the industrial switch on the network and make sure that any one of PC on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password is as below m P Address 192 168 1 5 B Subnet Mask 255 255 255 0 R Default Gateway 192 168 1 254 22 E User Name admin RB Password admin System Login wesch Launch the Internet Explorer on the PC Key in http the IP address o
31. nnot be existed at the same System Log Set up system log events and view the system log events System Log Configuration View the system log events in here B Click Reload button to get newest system log event RB Toclear the log events click Clear button m f log event list more that one page drag down the list to switch to different page B System Log Client Mode user can select in Client Only Server Only or Both mode 60 m System Log Server IP Assign the system log server IP m And then click Apply button to apply the configuration System Lo System Log Configuration Event Configuration Client Only DI Apply 1 Jan 1 00 08 50 System Log Enable page DI Reload Clear System Log Configuration interface Event Configuration User can select the system log events When selected events occur the system will send out the log information Also per port log events can be selected RB System event selection 4 selections Device cold start Power status SNMP Authentication Failure and Redundant Ring topology change Mark the checkbox to select the event When selected events occur the system will produce the logs gt Device cold start When the device executes cold start action 61 the system will produce a log message Power status When the device power status has changed the system will produce a log message SNMP Authentication Failure When the SNMP authentication
32. on 58 Pale COMO eeben 59 SV SUSI LOO BEE 60 Troubles stuer pel ees esse cesses seene eenn 63 Technical Specification ssscsseeeeeessssesseesees 64 Introduction The 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring is a cost effective solution and meets the high reliability requirements demanded by industrial applications The 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring can be easily managed through the Web GUI By using fiber port can extend the connection distance that increases the network elasticity and performance It also provides the Redundant Ring function that can prevent the network connection failure Features Conform to IEEE 802 3 10Base T 802 3u 100Base TX 100Base FX 6 port 10 100TX plus 2 port 100FX port industrial switch RJ 45 port support auto MDI MDI X function Store and Forward switching architecture Wide range redundant power design DIN rail and wall mount design Easy configuration design 2K MAC address table Web management GUI Per port supports 4 priority queues Provides Fiber link ability IEEE 802 3x flow control support gt Flow control with full duplex gt Back pressure with half duplex Support Class of service Support IGMP with Query mode for multi media application Supports ingress packet filter and egress rate limit Support SNTP SMTP Port mirror for TX or TX and RX packet
33. p function and dual homing function that prevent connection lose between Redundant Ring group and upper level core switch m Enable Redundant Ring To enable the Redundant Ring function Marking the check box to enable the Redundant Ring function 48 m 1 amp 2 Working Ports Assign two ports as the member ports One port will be working port and one port will be the backup port The system will automatically decide which port is working port and which port is backup port RB Enable Coupling Ring To enable the coupling ring function Marking the check box to enable the coupling ring function RB Coupling port Assign the member port Control port Set the switch as the master switch in the coupling ring Enable Dual Homing Set up one of port on the switch to be the Dual Homing port In an Redundant Ring group maximum Dual Homing port is one Dual Homing only work when the Redundant Ring function enable R And then click Apply to apply the configuration Redundant Ring T Enable Redundant Ring ist Working Port Port 2nd Working Port Port 02 e IT Enable Couple Ring Coupling Port Port Control Port i IT Enable Dual Homing Apply Help Redundant Ring Interface NOTE 1 When the Redundant Ring function enable user must disable the RSTP The Redundant Ring function and RSTP function cannot exist at the same time 2 Remember to execute the Save Configuration action otherwise the ne
34. pdating make sure user have user TFTP server ready and the firmware image is on the TFTP server B TFTP Server IP Address Key in user TFTP server IP B Firmware File Name Key in the name of firmware image R And then click Apply TFTP Update Firmware H 92 168 16 2 Apply Help TFTP Update Firmware interface Factory Default Reset Switch to default configuration Except the IP address subnet mask default gateway username and password will remain as user configured B Click Default button to reset switch to default setting 57 Factory Default Please click Default button to restore factory default setting Default Help Factory Default interface System Reboot Reboot the Switch in software reset Click Reboot button to reboot the switch system Reboot Please click Reboot button to restart switch device Reboot System Reboot interface Save Configuration Save the industrial switch configuration to the flash memory Power off the industrial switch without the saving all changed configuration will lost Click hne SaveFlash button the save the configuration save Configuration Save Flash Help Save Configuration Interface 58 Rate Control Set up every port s bandwidth rate and packet limitation type m Limit Packet type Select the packet type that wants to filter The packet types have all type packet broadcast multicast unknown unicast packet broadcast mu
35. ply button Alert Email Alert Configuration Event Configuration Power Alarm Configuration Cl Bower Cl Power2 Apply Power Alarm interface 38 IP Configuration User can configure the IP Settings and DHCP client function DHCP Client To enable or disable the DHCP client function When DHCP client function is enabling the industrial switch will be assigned the IP address from the network DHCP server The default IP address will be replace by the DHCP server assigned IP address After user click Apply button a popup dialog show up It is to inform the user that when the DHCP client is enabling the current IP will lose and user should find the new IP on the DHCP server To cancel the enabling DHCP client function click cancel IP Address Assign the IP address that the network is using If DHCP client function is enabling and then user don t need to assign the IP address And the network DHCP server will assign the IP address for the industrial switch and display in this column The default IP is 192 168 1 5 Subnet Mask Assign the subnet mask of the IP address If DHCP client function is enabling and then user do not need to assign the subnet mask Gateway Assign the network gateway for the industrial switch The default gateway is 192 168 1 254 And then click Apply button IP Configuration DHCP Client Disable DI IP Address 192 168 1 5 ubne Kj 255 255 255 0 Gateway 192 168 1254 Apply Help
36. ps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet B Diagnosing LED Indicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems user may encounter and where user can find possible solutions B f the power indicator does turn on when the power cord is plugged in user may have a problem with power cord Than check for loose power connections power losses or surges at power outlet If user still cannot resolve the problem contact user local dealer for assistance B If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check user system s Ethernet devices configuration or status 63 Technical Specification The 6 port 10 100TX plus 2 port 100FX SNMP Managed Industrial Ethernet Switch with Redundant Ring technical specifications are as follows IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX and 100Base FX Fast Ethernet IEEE802 3x Flow Control and Back pressure IEEE802 1d spanning tree IEEE802 1w rapid spanning tree Standard IEEE802 1p class of service IEEE802 1Q VLAN Tag Protocol CSMA CD SNMP management Management Web interface management One default button for system default setting RFC 1213 MIBII RFC 1493 Bridge MIB RMON RFC 1757 RFC 2674 VLAN MIB RFC 1643 Ethernet
37. rule Max Age 6 40 the number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 the time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 NOTE 1 Must follow the rule to configure the MAX Age Hello Time and Forward Delay Time 2 x Forward Delay Time value 1 gt Max Age value gt 2 x Hello Time value 1 2 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 45 Rapid Spanning Tree System Configuration Per Port Configuration Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 Apply Root Bridge Information 8000001122334455 32768 Rant 200 a RSTP System Configuration Interface Per Port Configuration Configure path cost and priority of every port R Select the port in Port column m Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through
38. rver Field Automatic device Field Automatic device Field Automatic device Coupling Ring Application In the network it may have more than one Redundant Ring group By using the coupling ring function can connect each Redundant Ring for the redundant backup It can ensure the transmissions between two ring groups will no failure The following figure is a sample of coupling ring application 20 Coupling Ring Backup Path Backup path a E TTT TTT TTT TTT N a Coupling Ring Group Redundant Ring Group B Redundant Ring Group A Fa Dual Homing Application Pd 4 Backup path Dual Homing function is to prevent the connection lose between Redundant Ring group and upper level core switch Assign two ports to be the Dual Homing port that is backup port in the Redundant Ring group The Dual Homing function only work when the Redundant Ring function is active Each Redundant Ring group only has one Dual Homing port NOTE In Dual Homing application architecture the upper level switches need to enable the Rapid Spanning Tree protocol i Eth t Switch m Enemet Swich a Rapid Spanning Tree Protocol T Sme en mas ere T ae RRR RER RTS Weem Wan Hot Standby Link l Redundant ring i Industrial backup link F 7 Switch LIS Industrial Switch 7 N Industrial g Industrial Switch Redundant Ring A T Industrial T Redundant Ri
39. strial switch 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation H user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cable category 5 to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning NOTE Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 cable 17 7 When all connections are all set and LED lights all show in normal the installation is complete 18 Network Application This chapter prov
40. t Ring Redundant Ring provides a faster redundant recovery than Spanning Tree topology The action is similar with STP or RSTP but the algorithms not the same In the Redundant Ring topology every switch should enable Redundant Ring function and assign two member ports in the ring Only one switch in the Redundant Ring group would be set as a backup switch that one of two member ports would be blocking called backup port and another port is called working port Other switches are called working switches and their two member ports are called working ports When the network connection failure the backup port will automatically become a working port to recovery the failure The switch supports one Dip switch for setting the switch as the ring master or slave mode The ring master has the rights to negotiate and place command to other switches in the Redundant Ring group If there are 2 or more switches are in master mode then software will select the switch with lowest MAC address number as the ring master The Redundant Ring master ring mode will be enabling by the DIP Switch When the switch is set to the master ring mode the Redundant Ring configuration interface will display the switch as the master ring message Also user can identify the switch as the ring master from the R M LED panel of the LED panel on the switch The system also supports the coupling ring that can connect 2 or more Redundant Ring group for the redundant backu
41. ton B To modify existing VLAN group press Edit button NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 31 802 1Q VLAN Tagged based VLAN is an IEEE 802 1Q specification standard which it allows to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers All ports on the switch belong to default VLAN VID is 1 The default VLAN can t be deleting The maximum VLAN group is up to 64 VLAN groups VLAN Configuration VLAN Operation Mode Jon H DI IT Management van ID fo Apply Basic Port YLAN ID DEFAULT_1 Add Edit Delete Previous Page Next Page Help 802 1q VLAN interface RB Click Add button R Management VLAN ID It is used for Remote Management Security In fact it can remote management that includes telnet SNMP and 32 Web browse the switch only when the port of VLAN group ID is equal to the Management VLAN ID Fill the specific VLAN ID number in Management VLAN ID column and mark the check box and then click Apply button to enable the function For example the management VLAN ID is 101 the VLAN group ID 101 includes the port 1 2 and 4 Therefore only port 1 2 and 4 can remote management the switch And if the port is in two different VLAN groups an
42. w configuration will lose when switch power off 49 QoS Configuration Configure Qos setting of the every port B Oos Policy Select the Qos policy rule gt Using the 8 4 2 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from Hi to lowest queue For example the system will process 8 high queue packets 4 middle queue packets 2 low queue packets and the one lowest queue packets at the same time Use the strict priority scheme The higher queue will always be process first except higher queue is empty B Priority Type Every port has 5 priority type selections gt Port base The port priority will follow the default port priority that user have assigned High middle low or lowest COS only The port priority will only follow the COS priority that user have assigned TOS only The port priority will only follow the TOS priority that user have assigned COS first The port priority will follow the COS priority first and then other priority rule TOS first The port priority will follow the TOS priority first and the other priority rule COS priority Set the COS priority level 0 7 R TOS priority The system provides 0 63 TOS priority level Each level has 4 types of priority high mid low and lowest The default value is Lowest priority for each level When the IP packet is received the system will check the TOS level value in the IP packet has received
43. w control Set flow control function is Symmetric or Asymmetric in Full Duplex mode The default value is Disable m And then click Apply button to apply all configuration m When user select the port user can see port current configure shows in below column Port Configuration Port ___ State__ Negotiation Speed Duplex Flow Control lede 4 Port Type Link Negotiation Speed Duplex Flow Control Port Control interface Switch Setting Assigning the system name location and view the system information RB System Name Assign the name of switch The maximum length is 64 26 bytes RB System Description Display the description of switch Read only cannot be modified B System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Display the switch s firmware version Kernel Version Display the kernel software version Hardware version Display the switch hardware version MAC Address Display the unique hardware address assigned by manufacturer default Switch Settings 6 10 100TX 2 100FX Managed Industrial Switch Switch settings interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off Port Mirroring The Port mirroring is a method for monitor traffic in switched
44. y The industrial switch supports port based and 802 1Q tagged based VLAN In the default configuration VLAN operation mode default is Disable VLAN Configuration VLAN Operation Mode Disable D LAN NOT ENABLE VLAN Configuration interface Port based VLAN Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored 29 In order for an end station to send packets to different VLAN groups it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol VLAN Configuration VLAN Operation Mode Port Based lt Add Edit Delete Previous Page Next Page Help VLAN PortBase interface B Click Add to add a new VLAN group The maximum VLAN group is up to 64 VLAN groups m Entering the VLAN name group ID and grouping the members of VLAN group R And then click Apply 30 YLAN Configuration VLAN Operation Mode Port Based DI Group Name VLAN ID H Add Remove Apply Help VLAN PortBase Add interface B The VLAN group will list B To view the another VLAN groups click Next Page R To delete unwanted VLAN click Delete but