Aerosol Therapy Nebuliser SC 145
Contents
1. Turn the compressor off and unplug it from the wall before you start cleaning The device must never be submerged in water for cleaning Use a damp cloth to clean the housing unit Never use thinner alcohol or flammable chemicals for cleaning Changing the air filter Change the air filter on the right side of the device as soon as it is dirty or is no longer white You can order more air filters via Customer services 11 Cleaning disinfection and drying of all accessories Cleaning Disconnect the sprayer and the other accessories such as mask mouth and nose pieces from the hose Open the sprayer by turning the upper part and separate it into its components upper part nozzle lower part Clean all sprayer and accessories under warm running water at at least 40 C using commercially available detergents The cleaning process should be done thoroughly and should take 5 minutes Then rinse all cleaned parts thoroughly in 40 C warm running water Shake to remove drips Alternatively you can clean the disassmbled sprayer and the other components in the dishwasher In this case place the components in the dishwasher s cutlery basket and clean in a separate short cycle on at least a 50 C program note Do not wash components together with dirty dishes Disinfection Disinfect the disassembled sprayer and other components directly after cleaning excluding the masks in boiling water Demineralised or distilled water is pre
2. is not possible to eliminate the possibility of interaction We recommend that you use up open medicines as soon as possible and that you do not store any medicines in the nebuliser Device description The Sprayer The sprayer is made up of three components The sprayer lower part the nozzle and the sprayer upper part Zerstauberaberteil Lufteintrittsofinun Sschiauchanscniuss Buse F eerstauberunterteil Buchse fur r R Netzkabel K t Ein Aus Schalter Lufteintrittsofinung The scaling is only an approximation and is not suitable for determining correct drug dosage Setting up the device Before each use the nebuliser and accessories should be cleaned in accordance with instructions in Cleaning and disinfection 1 Open the sprayer by turning the upper part anti clockwise and enter the prescribed medicine into the sprayer lower part 6 Drying Place all disinfected components on a tea towel or paper towel and let them dry for at least 4 hours After a 6 month period of use the sprayer should be changed for mechanical and hygienic reasons You can order a new one via the customer service center Storage of the sprayer and other accessories Between regular uses these parts should be wrapped in a dry cloth and kept in a dust free location For a longer storage period protect it with a dry cloth together with the compressor included in the retail box Cleaning of the compressor
3. After the end of the guarantee period you wil retain the option to send the defective product back to the service center for repair After the end of the guarantee period any repairs made will be at your own expense EI On OSSCrIDIOMN ss sce utareu san EE EA E E O Na N Customer name Postal code location WE UINO O E ae scala Aerosol Therapy Nebuliser SC 145 Instructions for use Table of contents Intended use Safety instructions Device description Included in the delivery The nebuliser Setting up the device Correct use of the device e For which respiratory diseases e Correct inhalation e Important factors in inhalation Benefits of inhalation therapy Cleaning and disinfecting Changing the air filter Technical data References and standards Electromagnetic compatibility Important symbols Components and accessories Disposal information Customer service 10 11 12 13 13 14 14 Warranty card 15 6 Guarantee card please Include details of your complaint Specification Inhalation device SC 145 The warranty period is 2 years and begins on the day of purchase i e the day goods transfer For the assertion of warranty claims you will need to provide your receipt as well as a completed guarantee card We advise that you keep these in a safe place The manufacturer guarantees the free correction of defects caused by faulty materials or bad workmanship They reserve the right to offer repair exc
4. ferrable for this purpose Let the water boil in a sufficiently large pot for about 15 minutes Use sufficient water to prevent the accessories from burning to the bottom of the pot a WARNING The maximum capacity is 8ml 8cm the minimum capacity is 2ml 2cm A corresponding scale is printed on the sprayer lower part see page 6 This is only intended an approximation and is not suitable for measuring dosages Finally replace the sprayer upper part and screw it in anti clockwise The sprayer is now closed 2 Plug the device in 3 Connect the sprayer to the device using the hose Insert one end of the hose into the lower part of the sprayer and the other end into the hose connector on the device 4 Select the attachment for the Sprayer mask mouth piece or nose piece 5 Use the on off switch to activate the device 6 After use turn the device off and unplug it from the mains If condensation gathers in the hose or if a small amount of the drug accidentally feeds into it you should stop the treatment remove the sprayer and the hose and washe them under warm running water with commercial washing up liquid Dry the hose by connecting it to the hose connection on the device and allowing air to flow through Correct use of the device Once you are familiar with the device and how it works you can begin to inhale Caution The sprayer only works if it is held vertically This means that the best position for in
5. haling is sitting down Inhaling whilst lying down is not possible Breathe evenly while inhaling Inhaling should feel comfortable Consult your doctor if this is not the case The application time should not exceed 10 12 minutes Which diseases can be treated with inhalation Respiratory diseases do not occur only in adulthood but increasingly also in childhood Inhalation devices are designed not only for chronic conditions such as asthma bronchitis or allergies but can also be used to treat smokers cough and the effects of occupational exposure to polluted air Inhalation may ease tickly coughs and open up the nasal passages during a cold enabling easy breathing Inhallation can also have a soothing emollient effect on pollen and dust allergies Correct inhalation The success of inhalation depends on the selection of the correct medicine These can only be prescribed by your doctor Only your doctor can 8 set the correct dosage and duration of treatment In the case of non prescription drugs your pharmacist will be able to advise you Important factors in inhalation e Take your time Assume a relaxed upright sitting position Breathe the inhalant in deeply and evenly through your nose or mouth Hold it for 2 or 3 seconds Then calmly and evenly exhale Repeat this process until the medication is consumed no more vapour is generated or the recommended duration of treatment is reached 10 12 minutes These breathing tech
6. hange or reimbursement The warranty does not apply in the case of accidental damage caused by an unforeseen event e g lightning water fire etc improper use or transport disregard for the safety and maintenance instructions or in the case of damage caused by improper adjustment or repair The statutory warranty obligation of the transferor is not limited by this warranty The warranty can only be extended if required by a legal norm In countries in which a mandatory guarantee and or a spare parts inventory and or a compensation system are legally required the minimum legally mandated conditions apply 15 mponents and accessories duliser mouth piece nose piece PP polypropylene sks and hose PVC polyvinyl chloride Disposal information After the end of its useful life this product should be appropriately disposed of via a local collection point for electrical appliances If this product is illegally disposed of sanctions according to the directive 2002 96 EC of the transposition laws of the member state wherein the product was disposed may be imposed Flaem Nuova S P A Importer SCALA Electronic GmbH Via Colli Storici 221 Ruhlsdorfer Stra e 95 S Martino della Battaglia D 14532 Stahnsdorf 051 Brescia Italy Germany Service address Sensorelectronics Stahnsdorf GmbH Ruhlsdorfer Str 95 D 14532 Stahnsdorf Tel 03329 604314 14 Purpose e The nebulizer system SC 145 consisting of the compressor and
7. niques should be practiced Benefits of inhalation therapy With nebuliser SC 145 liquid medicines can be _ finely atomised It creates a fine mist with droplet sizes between 1 and 5 um Droplets of this size can penetrate the upper and lower airways so the active ingredients reach their destination This makes aerosol therapy effective and efficient Low active ingredients local application and good compatibility are only some of the many benefits of inhalation therapy 9
8. or or recommended by your pharmacist for aerosol therapy e Before each use make sure that the power cord is not damaged A device with a damaged mains cable should be taken out of operation immediately and sent back to the customer service for maintenance e Never use a power supply that does not match with the information on the bottom of the device label Always unplug the device after use e Never block the air inlets on the side of the device They serve the ventilation and cooling of the motor e Do not exceed the maximum capacity of the nebuliser 8 ml 8 cm e Micro bacterial contamination As 100 disinfection in domestic use is often not possible it is strongly recommended that each user have their own personal accessories and use only these A corresponding re order card is included with each device 4 Via medicinal products certified and classified as a Medical product of the class Ila The inhaler SC 145 complies with the EU safety standards EN 60601 1 1990 A1 1993 A2 1995 A13 1996 EN 60601 1 2 1993 EN 60601 1 2 2001 and ergonomic standards required of a medical electrical appliance Furthermore the EU Standard EN 13544 1 2007 Respiratory therapy equipment part 1 Nebuliser systems and their components is met The manufacturers quality assurance system is certified according to EN ISO 9001 2000 and ISO 13485 2003 Symbols used me Never use the appliance in the bath or shower N Device type B
9. see user manual N O Class Il equipment No latex C Switch off Indicates that the cd EMAlets all K EURblevant standards gt Switch on ews Alternating current 13 Technical Data Voltage 230 V Hz Power consumption 130 VA Fuse T2 5A 250V Max operating pressure idle approx 150 kPa Operating pressure with nebuliser About 65 kPa Air outlet approx 9 l min Noise level in 1 m approx 57 dB A Operating conditions 10 C to 40 C 10 to 95 RH Storage conditions 25 C to 70 C 10 to 95 RH Operating storage air pressure 690 hPa to 1060 hPa P Nebuliser Min max capacity 2 ml 8 ml Max nebulisation power approx 0 30 ml min MMAD EN 13544 1 2 6 um Respirable fraction lt 5 um 99 These are average values and are based on a 0 9 physiological solution Certified with computerized TSI Aerosizer 3220 laser system Subject to changes in light of technical progress Standard reference The product has been approved according to the council directive 93 42 EEC of 14 June 1993 Included in the delivery The delivery includes Nebuliser SC 145 sprayer mouth piece nose piece mask 40 for childern mask for adults hose air filter and power cord e Interactions The components which will come into contact with medicines have been tested with a wide range of pharmaceuticles However in view of the large number of medicines on the market and their constant advancement it
10. the nebuliser RF 5 Plus is an effective aerosol therapy system for diseases of the upper and lower respiratory tract e The appliance is not suitable for pure oils powdered or solid medicines e Oily medicines should be mixed in the ratio 1 1 with a physiological solution designed for inhalation available in pharmacies e You should always consult you doctor or pharmacist about the correct liquid medicines to use Safety information e Before the initial use be sure that you read the instructions through carefully e This product is designed only for the nebulisation of liquid pharmaceuticals aerosol therapy Any other use is considered dangerous and illegal This product should not be used in connection with any narcotic substances or solutions which are flammable in air oxygen or laughing gas e Clean the accessories before the initial use Clean the accessories after each use e Check for damage to the nebuliser and the accessories before each use e Protect your device and its accessories against high heat e Do not use this device in damp rooms i e in the bathroom after a shower etc 3 e Do not immerse the appliance in water or any other cleaning product This device is not protected against liquid infiltration e Do not use the device while you sleep e Children and disabled people should use this device under supervision e Use this device according to instructions from your doctor e Use only medicine prescribed by your doct