Home

vistaHD user manual

image

Contents

1. Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com user defined output to this input output to this input The switch lights up red to indicate when selected Menu 04 07 Set up Controls Menu Heading Automation Function Num 4 O P 1 1 to 4 default is This button will select which 1 input is routed to the output INPUT 1 Pressing return will bring up a cursor enabling the user to type user their required label for the defined currently selected input Pressing return again will store the new label and return to normal operation 5 Extn Info only This menu indicates the Sync presence or absence of external syncs absent 6 Sync 0 Auto 1 INT This menu option selects the source sync source used to 2 EXT default is synchronise the line switching INT 1 INT of the inputs The options are using the Internal reference an External input or automatically trying to lock to an internal source when present 7 Switch 1 to 288 default This option selects on which Line 6 is 6 video line the inputs are switched between inputs eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 08 11 Power on option Menu Heading Automation F
2. the port to work a flexiPanel MUST be connected locally on the front of the flexiBox Automation control of the NS 41 can be done using two protocol methods e geNETics Automation Protocol e PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol PresTX Automation Protocol is used only for the PresTX Presentation Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual On most flexiBoxes later than 1 10 02 the RS422 port has been replaced by a D Bus Port The D Bus port is for High Speed data transfer and is not used for serial control In order to achieve serial control of any products on an l Bus network Eyeheight Ltd have developed a RS232 gt l bus converter dongle DG 9 which enables greater flexibility of products on the I Bus network whilst using the same protocols as the RS422 port Please refer to the User guide for the DG 9 eyeheight dongle and set up software 9 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 3 Assigning names to the four NS 4I inputs Names may be assigned to the four NS 41
3. 41 card 2 2 Installing the NS 4I into a flexiBox To install the NS 41 into a flexiBox it is desirable but not necessary to power down the flexiBox Follow these instructions On the rear of the flexiBox are 6 slots for Products Remove any pair of spare blanking plates one above another There are 2 off M2 5 Screws which require unfastening for each blanking plate Slide the Product PCB into the spare slots and firmly push it home Use the two thumbscrews to fasten the unit in place Take care that the ribbon cable for the upper circuit board stays attached to the lower board Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you through acquiring your product as a device on the flexiPanel 2 3 Connecting to an NS 4l Connections are simply four SDI inputs switched to one SDI output ro of 4 ff Input 3 Input 4 Output Input 1 Input 2 Figure 2 1 connections of an NS 41 module Ey oe eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 4 Connecting Panels to the NS 4l The NS 41 may be operated using a FP 9 or FP 10
4. Flexipanel locally or remotely mounted For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexiBox in the geNETics Hardware Installation Guide Below is shown a typical system consisting of an NS 41 in a flexiBox controlled by an FP 9 T 8 eyeheight Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V Use cable with a least a 1 amp rating for pins 1 4 9 Cable llength should not exceed 250m I Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power I BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for I BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for BUS Alternatively The termination can be set on a Product ie the AS 2 module Information about this is given in this manual N B From 1 10 02 Eyeheight introduced a change in the flexiBox Chassis Most versions now have two 9 way connectors on the rear labelled I Bus and D Bus The I Bus connector is the same as the previously labelled Can B connector Although a maxiBox is shown in this diagram the same arrangement app
5. ave Pressing this will Save Memory Mem 4 number 4 13 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 16 19 Memory Controls continued Menu Heading Automation Function Num 16 Save 1 Save Pressing this will Save Memory Mem 5 number 5 17 Save 1 Save Pressing this will Save Memory Mem 6 number 6 18 Save 1 Save Pressing this will Save Memory Mem 7 number 7 19 Save 1 Save Pressing this will Save Memory Mem 8 number 8 Menu 20 23 Control Menus Menu Heading Automation Function Num 20 Info none Information 21 Info none Information 22 Pass 1 on Pass control Contrl 23 Info none Information 14 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 24 27 Reset options Menu Num Heading Automation Function 24 Set As 1 save Pressing this will save the current Pow On set up as the power on default Memory 25 Recall 1 Recall Pressing this will recall the power Pow On on default settings Memory 26 TOTAL 1 Reset Pressing this will reset the system RESET 27 NS 41 N A Information about the current i
6. e Front of a 1RU flexiBox The order code is FP 9 A FlexiPanel can also be used in conjunction with a miniBox in this case the extra accessory Order code RR 9 will be required e FP 10 is a desk mounting control surface Order code FP 10 This unit is a modular unit which can be used in conjunction with the units below eyeheight e o o o o o Figure 1 3 FP 10 desktop modular panel 5 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com eyeheight Figure 1 4 FP 9 1RU panel 6 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Installation of the NS 4I product If this unit is already pre installed in a flexiBox FB 9 or a maxiBox with either a local or a remote panel from the factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a miniBox MB 9 then also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has been ordered separately we assume here that you already have a flexiBox system with a Flexipanel and that the flexiBox has at least two spare slots above each other for the NS
7. esdeateanncesiawleeasaxs 16 4 14 Technical Specification for the NS 41D cee cece eeeeee nesses eeeeeeeeees 16 P eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures FR TT NS 41 et age 25 Gass scete oaeeo or aeaea 4 Figure 1 2 FlexiBox with flexiPanel fitted 2 2 ccceceeeeeeeeeeee cence eee eeeeeeeeeeceees 5 Figure 1 3 FP 10 desktop modular panel isc inssicsscusiaisaerersadsabuncanndvvesnonsanaanalnnealan 5 Figure 1 4 FP 9 TRU Dame cconcicssacdojedsmeeciavescsudaastiuecicenedadecsvacidcetsaeduteodeevensenaay 6 Figure 2 1 connections of an NS 41 MOdUIE ceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 7 3 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System overview This manual describes the function of the NS 41 This unit is an electronic SDI video switcher The input video is simply switched and re clocked to the output One input can be replaced by an analogue reference source which enables the system to be set up and cut on any line A mechanical relay bypass is enabled if the power is removed and provides connection between input 1 and the output The NS 41 is a unit that will accept fo
8. eyeheight NS 4 four input non sync switch preview switcher user manual Table of Contents WSSU UN OV GT GY s esinen ede a nemece ys eeecesacynas A e EEEO E EEEE ESEE iad 4 1 1 Applications for the NS 41 00 2 0 cccccccceceeeeceeeeeeeeeeeeeeeeeeeeesseeeeseeeenees 4 1 2 Associated Equipment for the NS 41 ccccecceeeceeeeeeeeeeeeeeeeeeeeeenees 5 1 2 1 Chassis VY OS oer Sates he Ese eee ee 5 1 2 2 COMM Ol SUN ACES scenici oreinen e e ie e e rr anera 5 2 WS TAN wiicicas cassie css andosumtedanieinscloceraia MebediecedeinnsalceilaxeondebeeItiastucivesviiersum manures 7 2 1 Installation of the NS 41 product ccccccceeeceeeeeeceeeeeeeeeseeeeseeeeenees 7 2 2 Installing the NS 41 into a flexiBOX 00 cece cece e cece eeeeeeeaaeeeeeeeaeeees 7 2 3 Connecting to an NS 4licicieicsncsieedesiecssctradanunnsenebersiauncnedsanenasnedenasecn 7 2 4 Connecting Panels to the NS 41 0 ccccceecseeeeeeceeee eee ceee eee ceeeeenenteeees 8 3 Operation ni cass ee a E 9 3 1 Manual control of the NS 41 ioc cicccenessescccsacescsendescescanadanedenneneteaasedaaencn 9 3 2 Automation Control of the NS 41 aaneeaanaennnannnannenrrnennrnnrrnnrnnerrennnne 9 3 3 Assigning names to the four NS 41 inputs 0 cee eeeeeeee tere eeeeeeeee 10 3 4 Operational Menus for the NS 41 200 cccceececeeeeceeeeeeeeeeeeeeeeeeeeeeseees 10 4 Technical Appendix j1esccuseionsiscnsardeiniieadesionsidasnnanedbastensdeGubban
9. inputs These names appear on the menu 00403 LCD displays The four named sources to the NS 41 can be renamed The procedure is as follows e Plug in a PS 2 Keyboard into the flexiPanel that has control of the NS 41 e Ensure that the correct NS 41 is selected on the device buttons e Press F9 on the PS 2 Keyboard and the word TEXT should appear in the 4 LCD Displays e Type the following Example 1MainTX e Hit the RETURN key This will cause the Input 1 of the switch to be renamed MainTX To do the Input 2 side of the switch use the Prefix 2 e g 2Bypass and so on 3 4 Operational Menus for the NS 4Il The following set of menus defines the operation of the NS 41 Menu 00 03 Top level controls Menu Num Heading Automation Function 0 INPUT 1 1 switch Pressing this button switches the user output to output to this input The switch defined this input lights up red to indicate when selected 1 INPUT 2 1 switch Pressing this button switches the user output to output to this input The switch defined this input lights up red to indicate when selected 2 INPUT 3 1 switch Pressing this button switches the user output to output to this input The switch defined this input lights up red to indicate when selected 3 INPUT 4 1 switch Pressing this button switches the 10 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford
10. lies for a flexiBox chassis 8 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Operation 3 1 Manual control of the NS 4I Manual Control of the NS 41 is done using one or more of the following control surfaces e The 1RU FP 9 flexiPanel e The FP10 desk mounting Panel The FP 9 and the FP 10 have identical manual control systems The FP 10 is simply a desktop version of the FP 9 The NS 41 is as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the NS 41 Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 2 Automation Control of the NS 4l Automation of the geNETics products is achieved via an RS422 port This port is marked RS422 on the rear of a flexiBox For
11. ssue 040302 of software Ver1 6 15 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Technical Appendix 4 1 Technical Specification for the NS 4ID Number of Inputs 4 Input BNCs Type of Inputs 270Mbit Serial Digital Video Inputs 75 gt 0hm One BNC can be configured to be a video input to enable synchronised switching Line Length At least 75 Meters of PSF 1 3 Number of Outputs 1 Output BNC Type Of Outputs 270Mbit Serial Digital Video Outputs 75 Ohm 800mV Total Number Of 5 consisting of 4 Inputs and 1 outputs BNC Connections SDI Output Jitter The system will add less than 0 2UI to the input Jitter This is only guaranteed on issue 2 or later cards Current Consumption lt 800mA at 5V Size 215mm by 100mm 16 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
12. unction Num 8 Power 0 PowMem This option selects whether the UpMode unit stores the Last Input 1 LastOn selected or uses the Power On LastOn Memory default is LastOn 9 UNUSED 10 UNUSED 11 UNUSED Menu 12 15 Memory Controls Menu Heading Automation Function Num 12 MEM1 1 Recall Pressing this will recall Memory number 1 13 MEM2 1 Recall Pressing this will recall Memory number 2 14 MEM3 1 Recall Pressing this will recall Memory number 3 15 MEM4 1 Recall Pressing this will recall Memory number 4 l2 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 16 19 Memory Controls continued Menu Heading Automation Function Num 16 MEM5 1 Recall Pressing this will recall Memory number 5 17 MEM6 1 Recall Pressing this will recall Memory number 6 18 MEM7 1 Recall Pressing this will recall Memory number 7 19 MEM8 1 Recall Pressing this will recall Memory number 8 Menu 20 23 Memory Controls continued Menu Heading Automation Function Num 12 Save 1 Save Pressing this will Save Memory Mem 1 number 1 13 Save 1 Save Pressing this will Save Memory Mem 2 number 2 14 Save 1 Save Pressing this will Save Memory Mem 3 number 3 15 Save 1 S
13. ur SDI video inputs or three and a analogue reference source and has one SDI output The main features are e 4 inputs 1 output SDI video switch e input 1 can be used as an analogue reference input for switching on a particular line e Amechanical relay bypass from input 1 to the output e Control by FP 9 control panel 4 LCD legendable pushbutton switches for control e GP 2 GPI card available for remote GPI control Figure 1 1 NS 41 module Ll Applications for the NS 4l Applications for the NS 41 include the following e Apreview switcher e Emergency bypass switching 4 eyeheightUnit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com le Associated Equipment for the NS 4l The NS 41 is a module and requires both a chassis and a control surface to function l 2 1 Chassis Types e flexiBox is a 1RU chassis The order code is FB 9 This will hold a maximum of 6 NS 41 Modules with Hot Swap redundant PSU option and Hot Swap NS 41 modules e maxiBox is an alternative low cost 1RU chassis The order code is MX 9 This also will hold a maximum of 6 NS 41 modules but it has no redundant PSU option and the NS 41 units must be factory fitted Figure 1 2 FlexiBox with flexiPanel fitted l 2 2 Control Surfaces e flexiPanel is a IRU control surface that fits on th

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - 日立の家電品  Guida dell`utente di Synology NAS Basata su DSM 4.3  Honda HRB2153PDA User's Manual  Users manual  Oracle® e-Commerce Gateway  Manual de instalación del sistema NaviTouch  

Copyright © All rights reserved.
Failed to retrieve file