Contents

1. 5 Battery Charging full charging in 6 hours 6 Indication lamps charge level BATTERY 5 green LED charging status CHARGING 1 yellow LED sealing status SEAL 1 red LED on sealing unit SEALING 1 amber neon in head d Environmental Conditions The machine should be operated within the following environmental conditions 1 Indoor use only 2 Altitude up to 2 000 meters 3 Operating temperature 5 40 C 41 104 F Storage temperature 20 70 C 4 158 F 4 Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 Mains supply voltage fluctuations up to 10 of the nominal voltage 6 Transient overvoltages typically present on the mains supply Note The nominal level of transient voltages is impulse withstand overvoltage category II of IEC 60364 4 443 7 Applicable rated pollution degree Pollution Degree 1 SE70011UMC 0312 3 Appearance 3 1 Units RF cable connector he N ai TS RF cable connector Sealing lamp Sealing lamp Charging status lamp Battery charge level lamps Power switch Charging jack Trigger lever Sealing head Head protector Hand unit DC output plug Charger unit SE70011UMC 0312 3 2 Front panel of main unit TUBE SEALER un gt DOCS A 6 Y 0 51 00000 O o CHARGER POWER BATTERY CHARGING SEAL
2. 4 5 6 7 8 9 10 Cycle of Recharging Month in case of 20 recharging cycles month 10 SE70011UMC 0312 The chart shows a performance degradation tendency of Ni MH 12V 4 5AH battery packs The reason why it shows quite wide shaded area is that the Number of Sealing varies with many factors such as 1 Material and diameter of tubing 2 Room temperature tubing temperature and temperature of the sealing head 3 Number of discharging recharging cycles at the battery pack The chart data were made on the following condition 1 PVC tubing of diameter 4 4 mm 2 Room temperature at 23 C 3 Packs recharged 20 times per month What the chart indicates are 1 With a new battery pack approximately 1100 1500 seals could be made 2 In 6 7 months the number decreases down to almost half Assuming recharging is done once everyday 5 times a week 20 times a month When to replace the battery Refer to Section 4 2 How to replace the battery pack 11 SE70011UMC 0312 1 Prepare a flat tip screwdriver or a similar tool 2 On the rear panel remove the 4 screws to take off the rear panel assembly 3 Take out the battery pack and pull out to disconnect the battery connector 4 Replace it with a new pack and connect the battery connector 5 Carefully push the pack into the housing Be careful the wire harness and connector don t twist or jam in the housing 6 Assemble the rear panel assembly w
3. 7 0 2 3 4 O 1 Charging jack CHARGER It takes 18 volts DC from the charger unit 2 Power switch POWER It turns power on and off Pull the lever to flip 3 Battery charge level lamps BATTERY The five green LED lamps indicate battery charge level stored in the battery pack inside Each lamp denotes about 20 of full charge capacity of the battery The first left lamp flashes when charge level is 0 10 The first left lamp is turned on when charge level is 10 20 The second lamp is turned on when charge level is 20 40 The third lamp is turned on when charge level is 40 60 The fourth lamp is turned on when charge level is 60 80 The fifth lamp is turned on when charge level is 80 100 4 Charging status lamp CHARGING The yellow LED lamp is turned on when the charger unit plug is plugged into the charging jack The lamp flashes when charge level reaches to full charge 5 Sealing lamp SEAL The red LED lamp indicates RF power is being generated and applied to the hand unit The lamp is turned on by pulling the trigger level and is turned off automatically when a seal is made at tubing or in 3 seconds after 6 RF cable connector Connect the RF cable between this connector and the same connector on the hand unit SE70011UMC 0312 4 Operating Procedures 4 1 Sealing Tubing 1 Connect the RF cable between main unit and hand unit 2 Turn the power switch on Chec
4. USER S MANUAL TUBE SEALER Model SE700 No CAT SE70011Ce Centron Technologies Corporation 319 25 Sadang 4 dong Dongjak ku Seoul Korea 156 823 Tel 82 2 522 7807 Fax 82 2 522 7806 Important Note 1 Safety The machine generates strong high frequency power when the trigger lever is pulled Users should be cautious of potential electric shock during sealing process e To avoid potential electric shock always use the machine with the head protector mounted on sealing head e The machine works even without the head protector mounted on sealing head If you should use the machine without the head protector with any reason never touch any metal part at sealing head while you are pulling the trigger lever Finger may scald instantaneously due to generated high frequency power if touched at any metal part in sealing head while the trigger lever is being pulled or the red SEAL lamp is lit 2 Battery Recharging and Replacement e Recharge the battery prior to the first use For stable operation recharge it when two or more indication lamps are on Full charging may take 6 hours e The machine does not work during recharging The charger unit should be removed from charging jack in order that the machine can work Refer to the Section 4 2 e Replace the battery pack with a new pack when it seems the battery pack may have been degraded too much Refer to the Section 4 2 and 5 3 for details 3 Cleaning and Maintenance e Always
5. charger unit plug when the CHARGING lamp flashes Recharging may take up to 6 hours The first recharging may take longer Battery will not be overcharged or damaged even if left for longer time Note An independent charger unit BC167 is available that charges 6 machines same time Contact your distributor for information on BC167 charger unit When to replace the battery Battery packs are consumables Available battery capacity decreases gradually with time Battery pack should be replaced with a new pack after the machine has been used for some period Battery manufacturers usually guarantee cells for 3 to 6 months only but some field service reports show that it can go for a year or more sometimes up to three years Replace the battery pack if any of the following case happens SE70011UMC 0312 1 If no BATTERY lamp illuminates when the power switch is turned on recharge it once If no lamp is still turned on the battery pack may have been damaged or the machine may have some trouble Either replace the battery pack and try again or ask service 2 If the number of seals made with one cycle of full charging is significantly reduced e g below half of the number with a new battery pack the battery pack may have been degraded too much Replace the battery with a new pack Contact your distributor for spare packs Refer to Section 5 3 for more information on battery replacement How to replace the battery pack Refer to S
6. ection 5 3 5 Maintenance 5 1 Troubleshooting The following table covers common problems and suggested solution Other problems should be corrected by authorized service personnel lamp illuminates be damaged Refer to Section 4 2 and 5 3 Refer to Section 5 4 Sealing is poor Low battery charge level Recharge the battery eens st I Refer to Section 5 2 move smooth Refer to Section 5 2 Arc appears Wet or dirty sealing head Clean sealing head dry thoroughly Refer to Section 5 2 Number of seals per Battery may be damaged or Replace the battery pack full battery charge is be degraded too much with Refer to Section 4 2 and 5 3 significantly reduced long use SE70011UMC 0312 5 2 Cleaning The sealing head and clamp can easily be stained by dust or liquid Frequent cleaning will offer you the best long term results For proper cleaning use a dry cloth or a cloth dampened with water A mild detergent may be used Thoroughly dry the sealing head area before applying power If the sealing head is wet when RF energy is applied an arc may appear Follow the decontamination procedure of your facility as necessary Avoid spraying liquids in the sealing clamp or sealing head area How to take off and put on the head protector To take off push both sides To put on just push in How to disassemble and reassemble the clam D 6 To remove the clamp To install the clamp 1 Push in 1 Pull do
7. ith the 4 screws 5 Recharge the new pack It may take 6 hours Refer to Section 4 2 Disregard BATTERY lamp indication during the first charging Indication may be incorrect till charging ends Stop charging when the CHARGING lamp flashes 5 4 Service Call If the machine doesn t operate properly or if you need any assistance or spare parts contact your distributor 12 SE70011UMC 0312
8. k that battery charge level is good for working Recharge it if charge level is not sufficient For stable and continuous operation it is recommended that the battery pack should be recharged when two or more indication lamps remain lit 3 Place tubing in sealing head 4 Pull the trigger lever Watch that amber light turns on at sealing head 5 After amber light turns off wait for a while approximately one second or more and then release the lever 6 Remove tubing and inspect it 4 2 Recharging the Battery When to recharge the battery The BATTERY lamps indicate battery charge level stored in the battery pack Each lamp denotes about 20 of full charge capacity Refer to the Section 3 2 For the best operation recharge the battery pack when two or more indication lamps remain lit The machine does not work during recharging The charger unit should be removed from charging jack in order that the machine can work Recharging procedure 1 Plug the charger unit plug into the charging jack on the front panel of main unit The CHARGING lamp turns on As time goes on more BATTERY lamps turn on The power switch can be set at either ON or OFF position during recharging The CHARGING lamp may flash slowly for a while if recharging procedure starts when only the first lamp is on or the machine has been stored at a cold place 2 When charge level reaches to full charge the CHARGING lamp flashes rapidly Remove the
9. keep the sealing head clean and dry If the sealing head is wet or dirty arc may appear When it s wet clean it with a dry soft cloth or a tissue paper e Use a soft cloth and mild detergent to clean the units After cleaning wait a few minutes until the area cleaned is completely dry Do not use paint thinner benzene or strong detergent Refer to the Section 5 2 e Be sure to turn the power switch off before cleaning the machine e Only authorized service personnel should remove the covers of the main unit and the hand unit e Avoid pulling the trigger lever without tubing loaded in sealing head It consumes large amount of battery charge and may mar the sealing head e Never put sharp objects or metal objects in sealing head as damage can occur e Avoid using or leaving the machine in a location where temperature is over 40 C or 104 F Keep it away from any heating source or direct sunlight SE70011UMC 0312 Contents e Important Note 1 Features 2 Specifications 3 Appearance 3 1 Units 3 2 Front panel of main unit 4 Operating procedures 4 1 Sealing tubing 4 2 Recharging the battery 5 Maintenance 5 1 Troubleshooting 5 2 Cleaning 5 3 Replacing the battery pack 5 4 Service Call SE70011UMC 0312 10 12 1 Features The tube sealer model SE700 is a lightweight portable machine with a hand unit The machine is powered by a rechargeable battery pack When the trigger lever is pulled the machine generates s
10. trong high frequency power to melt thermoplastic tubing It makes seals on tubing in 1 2 seconds Indication lamps on the front panel indicate available battery charge and charging status For stable and continuous operation it is recommended that the battery pack should be recharged when two or more indication lamps are lighting Recharging to full capacity may take 6 hours Units and accessories are stored in the carrying bag during transportation and storage The figures below show configuration of the tube sealer SE700 RF cable Charger unit Carrying bag SE70011UMC 0312 2 Specifications a Physical specification 1 Main unit dimension WxHxD 148x34x252 mm 5 8 x1 4 x9 9 weight 1700 gram 3 8 lb 2 Hand unit dimension WxHxD 28x44x204 mm 1 1 x1 8 x8 1 weight 220 gram 0 5 Ib 3 Charger unit weight 300 gram 0 7 lb 4 RF cable length 1 8 m 6 feet weight 100 gram 0 2 Ib cord RG 58 5 Carrying bag dimension WxHxD 220x90x275 mm 8 7 x3 5 x10 9 weight 300 gram 0 7 Ib type material black canvas with shoulder strap b Power source 1 Battery pack 12V 4 5AH Ni MH cell rechargeable and replaceable 2 Charger unit Input 100 120 220 240 VAC 50 60 Hz 25 watt Output 18 VDC 1 ampere c Features 1 Tubing size to seal 6 mm 1 4 diameter max 2 RF frequency 40 68 MHz 3 Output RF power effective level 30 watts 4 Sealing time 1 2 seconds
11. wn 2 Pull down 2 Push in 3 Release it 3 Push up 4 Release it 9 SE70011UMC 0312 Cleaning procedure 1 Turn the power switch off 2 Remove the RF cable from the units 3 Remove the head protector 4 Remove the clamp 5 Clean the clamp the head protector and sealing head area thoroughly If you have used water detergent or decontamination liquid wait a few minutes to allow for thorough drying 6 Assemble the clamp and the head protector 7 Connect the RF cable between units 8 Turn the power switch on and test the machine 5 3 Replacing the Battery Pack Characteristics of the Battery Pack SE700 is powered by a battery pack BN123A It is a rechargeable battery specified as 12V 4 5AH Ni MH which is the most powerful energy storage cell available today All rechargeable batteries wear out so battery pack is a kind of consumables Charge capacity of a battery diminishes gradually with discharging and recharging Moreover at tube sealers as the machines draw exceptionally high amount of battery current during sealing battery degradation rate is higher than any other battery using devices Refer to the chart below Performance Degradation Curve of Battery Pack for Ni MH 12V 4 5AH Number of Sealing V 1600 1400 1200 1000 400 F 200 F l T l l i O m 20 40 60 80 100 120 140 160 180 200 r 1 2 3