Home

User Manual EN

image

Contents

1. 27 67 Internetowy sterownik kotta z kontrola temperatury spalin By UE p x SS A w LASS N 27 4 5 Domestic hot water temperature setting In the main screen press right arrow to enter Temperatura zadana CWU DHW set temperature screen Temperatura CWU 43 C Press up arrow to increase set temperature and press down arrow do decrease set temperature Press OK to confirm and select main screen Press ESC to cancel If down arrow 41 is displayed in the status window it indicates that the set temperature is reduced by the value set in Parametry u ytkownika Temperatura CWU Obnizona User parameters DHW temperature reduced and set DHW temperature may differ from set temperature Temperature setting range 35 C 60 C 4 6 Function fuel charge The controller generates event log entries and new fuel charge entries It may also indicate low fuel level in the hopper based on the feeder operation time required to empty the fuel hopper Feeder operation time to hopper emptying is available via website Current feeder operation time is displayed in the status screen CP POD item Press gt left or right arrow to display prompt to enter the fuel quantity charged to the hopper LT up and down arrow This function also enables controller registration on eSterownik pl website to generate automatic statistics on combusted fuel related costs and approximate boiler power 5 Controller p
2. Internetowy sterownik kotta z kontrola temperatury spalin 2 A 2 Lip 2 D ASS WS 27 b Automatic mode Automatic mode can be selected via control panel at the maintenance level or via web browser To switch the mode on via control panel select Tryb Pracy Operation mode with left right arrow and select Tryb Pracy lt auto gt Operation mode lt auto gt Trab Fraca lt auLo gt In the automatic mode some parameters for switching the devices ON OFF are not available Hold ESC to switch to automatic mode 4 4 Central heating temperature setting In the main screen press left arrow to enter Temperatura zadana CO CH set temperature screen Temreratura CU a tc Press up arrow to increase set temperature and press down arrow do decrease set temperature Press OK to confirm and select main screen Press ESC to cancel If down arrow 4 is displayed in the status window it indicates that the set temperature is reduced by the value set in Parametry uzytkownika Temperatura CO Obnizona User parameters CH temperature reduced and set CH temperature may differ from set temperature Temperature must not be reduced below Minimalna temperatura CO Minimum CH temperature Temperature setting range from Parametry zaawansowane Advanced parameters Minimalna temperatura CO Minimum CH temperature to Parametry zaawansowane Advanced parameters Maksymalna temperatura CO Maximum CH temperature
3. Dy SS Paz pump all modes Added Sustain cycle is forced after each controller fadeout reset Added DHW pump operation status depending on whether DHW pump is ON based on DHW algorithm green or mixing pump algorithm yellow Added Boiler put out analysis algorithm in sustain mode Added Cache Control header no cache for each file transmitted Added Cleaning unused EEPROM storage area Amended Incorrect display of blower power on the website at lt 30 power setting Amended Feeder OFF after switching from HEATING to sustain mode Amended Introduced DHW priority for Auto Lato Automatic summer Amended Analiza wygaszenia kot a w grzaniu Boiler put out analysis in heating mode Wygaszenie kot a Boiler put out alarm is generated in heating mode if flue gas temperature falls below 50 C and is maintained for at least 30 minutes Amended Circulation pump idle time reduced to 0 minutes circulation pump may operate in continuous mode Amended CH pump activation in LATO Summer mode gt 80 deg pump deactivation 5 deg below Amended DHW pump activation in LATO Summer mode gt 70 deg pump deactivation 5 deg below Amended Mixing pump operates depending on CH pump operation Pump activation temperature lt 39 0 deg deactivation gt 39 5 deg Amended Ram stopped on Uszkodzona kra c wka Damaged limit switch alarm activation when switching from automatic to manual mode during
4. browser bruli pl also enables easy software update via Internet bruli pl website developed for bruli pl controller users provides Remote Access to the controller via website if no public IP address is available Proxy server for communication with the controller without public IP address is also available 1 1 Intended use bruli pl controller is intended for automatic supervision of central heating boiler with an automatic screw ram feeder and a blower It may also be used to control domestic hot water DHW pump and in a systems fitted with a mixing pump it maintains minimum return water temperature The controller can also supervise fuel feeder operation fuel ignition back burning bruli pl is compatible with a PC fitted with SD memory card where all operation parameters are logged It also features Ethernet interface Implemented web server enables intuitive change of operation parameters preview of parameter alarm and event logs The controller may be programmed in daily and weekly mode via a website It also enables controller software update The latest controller software version is available on http bruli pl 1 2 Algorithm Group Combustion Burning solid fuels in a boiler with an automatic burner is a complex process both in respect of low fuel uniformity e g particle size and variable physical and chemical parameters essential for combustion processes Coal is an especially problematic fuel whose propertie
5. e A Ly ws Y WS 2 Y The service is free of charge 1 The first step is to sign up on http eSterownik pl click Zarejestruj sie Sign up 2 After signing up sign in select MENU and click Dodaj nowy sterownik Add new controller 3 The controller must be connected to a local network To connect see User manual Press Dalej Next if the website is available AKTUALNOSCI ZDALNY DOSTEP STEROWNIKI FAQ FORUM MAPA KONTAKT SKLEP PRODUCENCI KOT W Sterownik pl PLATFORMA STEROWNIK W ONLINE Podgl d i zmiana parametr w sterownik w ONLINE Przygotowany specjalnie dla u ytkownik w sterownika oraz portal umo liwiaj cy Zdalny dostep do sterownika przez strone www Przejdz do panelu Online Platforma sterownik w cz Mamy przyjemno przedstawi Pa stwu nowy portal eSterownik pl a w nim us ug Zdalny Dost p dla eo eo rro gt sterownik w eCoal pl lub bruli pl J mo zi z eron usluga W ZE Loerie RZAD SION em Platforma eSterownik pl daje u ytkownikowi nowe mo liwo ci przez Internet z wykorzystaniem przegl darki WWW e wysy anie powiadomie o alarmach i zdarzeniach w sterowniku na email i SMS e synchronizacj czasu w sterowniku z czasem na serwerze buforowanie plik w na serwerze szybsze ci ganie wykres w Portal eSterownik pl pozwala w prosty spos b omin cz ste problemy z dost pem do sterownika z sieci Internet ak publicen po adresu P fzsikownicy sisd e
6. if flue gas temp in 30 min will 13 ut out yg y not exceed 50 C Check boiler for impurities P sustain mode in sustain mode flue gas temperature will not rise by 5 C Incorrect sustain mode parameters 14 Wyczys kociot Clean the Boiler is dirty check heat exchanger and flue for boiler impurities 46 67 Alarm name Internetowy sterownik kotta z kontrol temperatury spalin p D Sir gt Lr Li by WS x We RE e Description 15 Wysoka t spalin High flue Excessive flue gas temperature check correct gas temperature installation of boiler heat exchanger components 16 Konflikt adr IP Incorrect IP Incorrect IP address IP address is used by another address device Btad pamieci EEPROM s 17 EEPROM memory error Controller memory error restore factory settings 18 Alarm zewnetrzny External KONT contact shorted on the controller board alarm universal alarm input 1 Pusty zasobnik Hopper Low fuel level in the hopper alarm does not stop 9 oe empty boiler operation It provides fuel combustion statistics 20 D ugi czas kra c wki Limit Limit switch did not return to initial position in set switch time too long time Limit switch did not return in set time Alarm 21 Nie zesz a kra c wka generated if after the ram activation the limit switch Limit switch did not return did not return in set time The situation may occur with feed
7. 9 Changed Remote access service server IP address 188 165 227 113 Amended Method of connection with Zdalny Dost p Remote access service Version 0 0 1 7 Changed Method of connection authorization with Zdalny dostep remote access service Passwords are generated on each connection with the server Changed CH set temperature in CWU LATO DHW summer mode set 5 C above DHW set temperature in heating mode Changed CH set temperature in CWU LATO DHW summer mode set to TEMP MIN CO Min CH temp if DHW heating is not required Version 0 0 1 6 Added Histereza CO CH hysteresis parameter in Parametry zaawansowane Advanced parameters menu Version 0 0 1 5 Improved communication with Zdalny Dost p Remote access service Amended error causing Wysoka temp spalin High flue gas temperature alarm 11 67 Internetowy sterownik kotta z kontrol temperatury spalin Added communication frame for reading all required parameters during website loading Extended parameter range Feeder operation idle time Version 0 0 1 4 First public version of bruli pl controller software 12 67 Internetowy sterownik kotta z kontrola temperatury spalin X m u gt NS o Ws ND EZ Z BA 1 Introduction bruli pl is a central heating boiler controller compatible with solid fuel boilers The controller enables remote operation and parameter setting via an internet
8. CO C 75 Al Temp zalaczenia pompy mieszajacej C 40 aj LS 1i Le Histereza CO C 1 0 E Niezale na praca pompy mieszaj cej Nie E sz ee T Czas pracy pompy CO dla reg wew min 15 4 Typ kot a Retortowy grupowe y i postoju pompy CO dla reg wew 60 S Maksymalna temperatura podajnika C 60 min 0 Czas wyrzutu paliwa min i2 s Funkcja pompy CWU CWU Okres rejestracji sek co 60 sekund Histereza CWU 9C 1 0 l2 Algorytm wygaszenia kot a Nieaktywny 18 bn ico Podbici sci a A A Temp zewnetrzna Auto Lato C 5 E Czas op znienia sek 30 s Histereza Auto Lato C 1 0 si Inwersja wej cia Nie 2 Zatrzymanie sterownika Nie 2 bruli pl 0 1 17 14 Dost p tylko do odczytu Alarmy Brak alarmow Fig 19 Advanced parameters window Weekly schedule for CH programmer is shown below Blue fields indicate reduced temperature yellow fields indicate normal temperature Click field to change colour and function Press Zapisz Save to confirm each change in the website panel 57 67 Internetowy sterownik kotta z kontrola temperatury spalin schemat Y Ustawienia Programatory Archiwum Pomoc bri uli pl Programator CO 0 1 2 dod FS Fe ld TPs E E FY CS YY 2 EJ Temperatura zadana CO 55 B Temperatura CO obni onao 5 zapisz odezytaj bruli pl 0 0 1 4 Dost p odczyt i zapis Alarmy Brak alarm w Fig 20
9. Ustawienia Settings gt Internet Internet gt Zdalne po czenie z serwerem Remote server connection and enter Identyfikator ID Adres IP serwera Server IP address and Port serwera Server port entered in remote access window Po czenie aktywne Active connection is set to TAK Yes 7 Click Zapisz Save The data can be set on the control panel press and hold OK press up and down to select Internet and press OK eenter the data in the control panel 62 67 Internetowy sterownik kotta z kontrola temperatury spalin SN 377 m Dodawanie nowego sterownika Dane podstawowe Nazwa Marek dom Udost pnij sterownik publicznie Sterownik publiczny jest dost pny do odczytu dla wszystkich Pe ne prawa ma tylko w a ciciel Udost pnij statystyki sterownika publicznie Synchronizacja czasu przez internet Dane do wpisania w sterowniku Wejd w sterowniku w menu Internet i wpisz nast puj ce dane Identyfikator 4A8D0B9784 Adres IP serwera 178 33 55 29 Port serwera 27854 Powiadamianie email W cz powiadamianie na email F Wiacz powiadamianie na email W cz powiadamianie na email Powiadamianie SMS Stan konta SMS 50 Prosimy wpisa tylko 9 cyfr bez dodawania 48 lub 48 W cz powiadamianie SMS na numer Fl W cz powiadamianie SMS na numer W cz powiadamianie SMS na numer al Wybierz alarmy wysytane SMSem Zadziatat termik CO Temp CO powy
10. Weekly schedule for CH programmer bruli pl controller records all operation parameters on the SD memory card The data are logged every 60 seconds 10 20 and 30 seconds interval can be set All parameters can be displayed as graphs The graphs may be zoomed in mark the area from the left to the right side or zoomed out mark the area from the right to the left side It is also possible to hide selected measurements click measurement in the graph key bruli pl controller logs Ethernet link data usage on SD memory card Data usage may be viewed as graphs send and received data The graphs can be zoomed and specific measurements can be hidden bruli pl controller logs all entries website sign ins on the SD memory card Connected hosts are also shown Inputs can be viewed as list of hosts input graphs by day time or by most viewed hosts 58 67 Internetowy sterownik kotta z kontrola temperatury spalin bruli pl Wykres z 24 02 2013 EH Temp co C A Temp zodono CO C MEN Temp wewn trzna C MEW Temp zod pok C WB Temp spalin C B Temp cwu c MA Temp zodono CWU C B Temp zewn trzna C BS Temp podajnika C B3 Temp powrotu c EM Temp podlog C EM Temp zod pod C 170 160 150 140 130 120 P 110 100 90 30 70 60 M ARANTZA AN saor TIT Pert Do P De P DADA ZA Mm ciu WIA M NN NAT Tu i ft Pg z w w aan a mae _ SE
11. aw S czkowski dom 40 6 C 42 0 C _ 37 79C 38 0 C Fig 26 List of controllers connected If there are issues with the controller connection check the connection with local network ping command or local sign in via internet browser and connecting local network to the Internet Check if data in the controller are correct 8 5 Sharing controller with other user This option allows to share the controller with other users You can share the controller with other users or with a service centre It will help with troubleshooting The service may view logged boiler operation data 1 Sign in on eSterownik pl 2 Select Zdalny dostep Remote access gt Twoje sterowniki Your controllers 3 Click selected controller on the list 4 Click Udostepnij Share 5 The following screen is displayed 65 67 Internetowy sterownik kotta z kontrola temperatury spalin ESTEROWNIK Mozilla Firefox Plik Edycja Widok Historia Zak adki Narz dzia Pomoc LS CO 6 ESTEROWNIK ESTEROWN K PLATFORMA STEROWNIKOW ONLINE Zdalny dostep Udostepnianie Seba eCoal pl O udost pnij sterownik publicznie tylko do odczytu Sebastian Charlak seba Pe ne prawa W a cicie i Ja ven Pelne prawa Usu Sterowniki Kamil T kamil Pelne prawa Usu Publicznie dostepne Twoje sterowniki Dodaj uzytkownika Ulubione sterowniki Dodaj nowy sterownik N Podaj jego login lub email Uprawnienia Tylko podg
12. comfort contact closed or reduced contact open The option may be selected in Ustawieniach uzytkownika User settings Regulator temperatury wewnetrzny Termostat Internal temperature controller Thermostat Higher boiler temperature is set with thermostat contacts closed With contacts open set temperature is lowered also CH pump may operate in cyclic or continuous mode or can be switched OFF set in Parametrach Zaawansowanych Advanced parameters 3 5 Connecting sensors to external alarm input The controller enables connection of potential free external sensors e g hopper hatch open sensor CO sensor CO2 sensor etc to Alarm zewnetrzny External alarm input see Fig 1 In Ustawienia zaawansowane Advanced settings menu user can set the controller response to input activation Czas op nienia delay time Inwersja wej cia input inversion and Zatrzymanie sterownika po zadziataniu alarmu controller OFF after alarm activation 3 6 Connecting control devices The controller can be connected to the following devices e Blower e Feeder CH pump 21 67 Internetowy sterownik kotta z kontrola temperatury spalin SS SS y ONE e DHW pump Mixing pump circulation pump or floor heating pump Connections shall be made in accordance with markings on the housing Disconnect mains plug before connecting disconnecting devices supplied by the controller Pompa CWU Pompa CO Pompa sa Podajnik Dmu
13. ej 90 C Uszkodzony czujnik CO Uszkodzony czujnik Spalin Fig 24 Main data when adding new controller 8 Fill in the remaining fields Miejsce instalacji Installation place and 63 67 Internetowy sterownik kotta z kontrol temperatury spalin Dane dodatkowe Additional data if required The data facilitate technical support using our FORUM 9 The following message is displayed Dodawanie nowego sterownika 1 Przejd do zak adki Ustawienia gt Internet gt Zdalne po czenie z serwerem w Panelu WVVW sterownika 2 Ustaw nast puj ce dane Zdalne po czenie z serwerem Po czenie aktywne rdentyfkator Adres IP serwera Port serwera Kliknij Zapisz w Panelu WWW 3 Upewnij si e sterownik jest pod czony do internetu oraz e wpisa e poprawnie powy sz konfiguracj ste gt Trwa czenie do sterownika Fig 25 Form for entering remote access parameters in the controller 10 User is informed about the correct connection with the controller The connection may take 5 to 60 seconds After the controller is connected a blue icon is displayed by the controller on Twoje sterowniki Your controllers list 64 67 Internetowy sterownik kotta z kontrola temperatury spalin WE OS ce ML NS E A We ES Lista Twoich sterownikow Sterownik T CO zadana T CWU zadana Alarmy eCoal pl Seba eCoal pl 25 7 C 50 0 C 25 7 C 45 0 C 1 alarm bruli pl Zdzis
14. is deactivated pompy al 9 lif return temperature is increased by 0 5 C Range pump activation temperature 25 C to 60 C 16 Maksymalna temp Setting maximum feeder temperature Feeder alarm is podajnika Maximum feeder temperature activated above set temperature Fuel is removed from the furnace if alarm is activated Fuel removal time is set with the next parameter Range 40 C to 44 67 Internetowy sterownik kotta z kontrola temperatury spalin Ss Parameter Description 110 C Parameter determines feeder activation time after s Zap on paliwa w podajniku Fuel ignition in the 17 pras Wy ratu paliwa tous feeder alarm is activated Fuel is removed from removal time the furnace to the ash pan for a set time Range 1min to 10min Boiler put out algorithm in sustain and heating mode based on flue gas temperature Nieaktywny Inactive boiler put out detection deactivated in heating and sustain mode In case the boiler is put out no alarm is generated and operation 18 Algorytm wygaszenia kot a is not stopped Boiler put out algorithm Tylko grzanie Heating only boiler put out detection in heating mode only Tylko podtrzymanie Sustain only boiler put out detection in sustain mode only Aktywny Active boiler put put detection in heating and sustain mode Potential free contact connected to Alarm zewn trzny Alarm zewnetrzny External alarm inp
15. mo na uzyska na stronie bruli pl w dziale FAQ Adres Ip 192468111 0 Login admin 7 Has o KOH Sprawd po czenie Aktualizuj stron WWW w sterowniku Post p ca kowity Post p cz ciowy HTTP Brak po czenia Fig 13 Software update Website can also be loaded from the zip archive directly onto the SD card 8 Website bruli pl controller features SD memory card and Ethernet module Website stored on the memory card enables controller maintenance via an internet browser The website allows user to modify operating parameters view alarm and event history display graphs with logged operation parameters and visualise current operation parameters To use website on bruli pl controller set Ethernet parameters in Internet Internet menu Adres IP IP address Maska Mask and Brama Gateway After setting parameters corresponding to the local network parameters user can sign in by entering the IP address set in Internet Internet Adres IP IP address menu Login and password are required to sigh in on the website 51 67 Internetowy sterownik kotta z kontrola temperatury spalin 8 1 Controller connection to local network The controller is connected to the local network in the same way you connect a PC Use cable with two RJ45 connectors to a free router or switch socket It is also necessary to set adres IP IP address brama gateway and maska mask Inter
16. mode if P y water requires heating Range 0 C to 10 C mode External temperature at which the controller switches from summer to winter mode For correct dA de AutoLato temp Automatic summer temperature 11 temper at re for ette mati mode operation external temperature sensor is bands mode required and Tryb pracy CWU DHW operation mode AutoLato temp Automatic summer temperature set Range 0 C to 25 C a Parameter determines hysteresis of switching from 12 Bo m de summer to winter mode in Auto Lato temp Automatic summer temperature mode Range SETERS 0 5 C to 5 0 C Pump operation mode selection pompa mieszaj ca mixing pump function maintaining minimum return water temperature Funkcja pompy pompa cyrkulacyjna circulation pump 13 mieszajacej Mixing pump function ensures continuous circulation of domestic function hot water from the heater to the tap pompa podtogowa floor heating pump floor heating function Temperature sensor connected to the terminals Floor heating sensor Items Niezalezna praca pompy Nie No Normal mixing pump operation 14 mieszajacej Independent depending on CH pump operation mixing pump operation Tak Yes Mixing pump operates irrespective of CH pump mixing pump operation in summer mode available with CH pump stopped Temperat ra zalaczenia Minimum return water temperature below which the 15 M miesza Sal Mixin mixing pump is activated Mixing pump
17. temperature in the room Czas pracy pompy CO CH pump operation time Parameter determines CH pump operation time for active room temperature thermostat thermostat and determined CH pump cyclic operation parameter 5 Range 1min to 99min Czas postoju pompy CO CH pump idle time Parameter determines CH pump idle time for active room temperature thermostat thermostat and determined CH pump cyclic operation parameter 5 Range imin to 99min Funkcja wyj cia pompy CWU DHW pump output function DHW pump operation mode CWU DHW DHW pump is used as a pump for filling the domestic hot water tank CWU miesz DHW mixing DHW pump functions as a pump for filling the domestic hot water tank and mixing pump and a mixing pump returning 43 67 Item Parameter Internetowy sterownik kotta z kontrola temperatury spalin Description the water to the boiler through DHW exchanger short circuit This function enables use of mixing pump output to connect circulation pump or floor heating pump Histereza CWU DHW DHW temperature hysteresis Above set DHW temperature deactivated DHW pump below DHW 9 hysteresis set temperature minus Histereza CWU DHW y hysteresis DHW pump is activated Range 0 2 C to 5 0 C dosa aj e RE Parameter determines C the CH set temperature is 10 pini s in DHW priorit P increased in Priorytet CWU DHW priority
18. zat pompy cyrkulacyjnej Programmer circulation pump programmer Circulation pump activation temperature Added new parameter Ustawienia Zaawansowane Temp zat pompy mieszajacej Settings Advanced Mixing pump activation temperature Floor heating pump deactivated in LATO Summer mode New operation parameters for cyclic floor heating pump operation Programatory Programator p podtogowej Czas pracy i Czas postoju Programmer Floor heating pump programmer Operation and idle time Added status field on LCD for floor heating temperature sensor T PODLG Version 0 1 17 5 Added New parameters Rejestracja danych na karcie SD SD card data logging every 60 30 20 10 sec Added New parameter Histereza dla reg pokojowego Room thermostat hysteresis 7 67 Internetowy sterownik kotta z kontrola temperatury spalin P U A ng 0 1 2 0 deg Added New parameter Histereza trybu Auto Lato Automatic summer mode hysteresis 0 5 5 0 deg Added New parameter Funkcja wyj cia pompy CWU DHW pump output function Added New parameter Funkcja pompy mieszajacej Mixing pump function Mieszajaca Mixing Cyrkulacyjna Circulation Podtogowa Floor heating Floor heating sensor must be connected to T ZAW controller output see FAQ Added New DHW operation modes AutoLato temp Automatic summer temperature AutoLato programator Automatic summer programmer Added Additional parameters for Alarm zewne
19. 0 C CH temperature for 10 C heating curve parameters setting available in Programatory Programmers An external temperature sensor is required for correct operation Activation of Programator pogodowy Weather compensation programmer is set in Parametry uzytkownika Regulator temperatury kotta User parameters Boiler temperature regulator Terr dla 18 C Terr dla 1BH L rid da C d Programator pokojowy Room programmer The programmer selects boiler temperature depending on the conditions in the 38 67 Internetowy sterownik kotta z kontrola temperatury spalin NS DA P Lig AU Ny wW room Room temperature programmer requires installation of internal temperature sensor Activation of Programator pokojowy Room temperature thermostat is set in Parametry u ytkownika Regulator temperatury wewn trznej User parameters Internal temperature regulator Pokojowy Room If internal temperature exceeds set value of the programmer set temperature is reduced by the CH temperature decrease value Additionally CH pump may operate in three 3 modes Continuous cyclic and OFF after reaching set temperature in the room CH pump operation mode after reaching set temperature is set in Ustawienia zaawansowane Advanced settings Tryb pracy pompy CO dla reg wewn trznego CH pump operation mode for internal regulator For cyclic CH pump operation operation and idle time are set with the following parameter
20. 3 Moc dmuchawy w grzaniu Blower power set in heating mode Range 2596 to Blower power in heating mode 10096 Determines when the heating mode is activated 4 inr E grzania Heating after sustain mode Range Dmuchawa podajnik feeder blower Tylko dmuchawa blower only czan postoju H Feeder idle time in sustain mode Range 3min to 5 podtrzymaniu Idle time in 3 360min sustain mode 6 Czas dopalania w gla Coal Blower operation time after fuel charge sustain aftercombustion time mode Range 5s to 360s 7 Krotno podawania Feed Blower operation time after fuel charge sustain multiplicity mode Range 0 to 20 M yprzedzenie Hmuehdwy W Parameter determines number of blower cycles in 8 podtrzymaniu Blower lead in i sustain mode Range 0 to 20 sustain mode moe dmuchawy Blower power set in sustain mode Range 25 to 9 podtrzymaniu Blower power 10096 in sustain mode MOC dmuchawy W trybie Blower power set in manual mode Range 25 to 10 recznym Blower power in 100 manual mode e Parametry spalania Combustion parameters typ Zasypowy Hopper type Combustion at an emergency grate with feeder stopped or for hopper type feeders The algorithm reduces blower power at flue gas temperature over 350 C and stops the blower at flue gas temperature over 400 C Item Parameter Description Czas przedmuchu Blow in time For set temperature over 8 C the controller au
21. A AAA AAA gt qu ed O 01 00 02 00 03 00 04 00 05 00 06 00 07 00 08 00 09 00 10 00 mainin EM 18 00 19 00 20 00 21 00 22 00 23 00 10 06 Temp zadana CWU C 43 44 e 10 06 Temp zadana CWU C 00 00 01 00 02 00 03 00 04 00 05 00 05 00 07 00 08 00 09 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 19 00 20 00 21 00 22 00 23 00 00 00 bruli pl 0 1 17 14 Dostep tylko do odczytu Alarmy Brak alarm w Fig 21 Diagrams with logged boiler operation parameters All alarms and events on the bruli pl controller are also logged on the SD memory card 59 67 Internetowy sterownik kotta z kontrol temperatury spalin bruli pl Panel WWW Mozilla Firefox X amp blhttp 192 168 0 7 b bruli pl Panel www szw 6 ee bruli pl 0 0 1 4 WB 58 6ooo Jm o E N Schemat Ustawienia Programatory Archiwum f Pomoc br uli pl M Zadziatat termik CO a Temperatura podajnika powyzej 90 C 74 Temperatura CO powyzej 90 C M Wygaszenie kotta MI Uszkodzony czujnik temperatury CO M zabrudzenie kot a M Uszkodzony czujnik temperatury spalin M B d pami ci EEPROM 74 Uszkodzony czujnik temperatury CWU M Wysoka temperatura spalin M Uszkodzony czujnik temperatury powrotu M Konflikt adres w IP M Uszkodzony czujnik temperatury wewnetrznej M Uszkodzony czujnik temperatury zewn trznej MI Tryb r czny automatyczny M Uszkodzony czujnik temperatury podajnika M Zatacze
22. Internetowy sterownik kotta z kontrol temperatury spalin bruli pl Internet boiler controller with flue gas temperature control User manual Kutno 28 02 2013 1 67 Internetowy sterownik kotta z kontrola temperatury spalin lt A o List of contents os A EAP EIO Z O A ac 14 LL IMtended USE gasi titi Eo EAP EA io poi R Oooo ki 14 1 2 Algorithm Group CombBuUstio asc o c w ic 14 1 3 Group combustion histogram was ici SG EA A WAG RAP PAW YE WAG a 16 LAS PROC OM acentos arts 17 2 Safety ER 18 A PP IA 20 3 1 Environmental condition S aa o dod GW GEO AG us asa Ad d 20 3 2 Installation of a control panel aaaa aa aaa aaa aaa aaa nr 20 3 3 Connecting measuring SENSORS aaa iGO EGO CJE es 21 3 4 Connecting room TtheltmosEab ss o dione cti od 22 3 5 Connecting sensors to external alarm input uaaa aaa aaa aaa aaanaaaa2 22 3 6 Connecting control devices iiie a a as 22 EN A 23 n 8 Ethernet conrgcLlofTiesassemexecseaaxsenskca ME radici I da RR RR ET RE ERES PLIENE 24 Controller operatio Mses cca dass 24 di 1 Control panel keyboattd toten rok nia 24 4 2 Control panel Maintenance level ecce 25 4 3 Controller operation MOJES Rusa das AEP A OR urds EI PES 27 a Manual Mode TREE m T Irena 27 b Automatic A e eN o bebida O O th 27 4 4 Central heating temperature setting ssssssssrrsssrrrrsssrrrsrrnrrrrrsrens 28 4 5 D
23. OS 4 Enter ipconfig and press Enter The required data are circled cx C WINDOWS system32 cmd exe icrosoft Windows XP Wersja 5 1 2666 lt C gt Copyright 1985 2661 Microsoft Corp Documents and Settings dominik gt ipconf ig Konfiguracja IP systemu Windows Karta Ethernet Local Area Connection Stan no nika No nik od czony arta Ethernet Wireless Network Connection Sufiks DNS konkretnego po czenia IPSE iria ojew ze eta iw d aD Adres 192 168 6 43 Maska podsieci a a a a a s 255 255 255 6 Brama domy lna q 192 168 6 254 Documents and Settings dominik gt Fig 15 Console window in Windows OS 5 Set identical brama gateway and maska mask IP address must be different Change the last IP address for example 192 168 0 69 6 Check if the IP address is not used by other devices 53 67 Internetowy sterownik kotta z kontrola temperatury spalin ny SS o 9 DI ABS DD gt 2 Enter ping 192 168 0 69 and press Enter If similar message is displayed 192 168 6 1 bajt w 32 cz TTL 128 Odpovie 192 168 0 1 bajt w 32 cz TTL 128 m C ie Q 5 a ha E 3 Q select other IP address if the following message is displayed Up yn limit czasu dania Up yn limit cz dania Up yn limit czasu dania continue 7 Enter gateway and mask previously read in the console and se
24. ation is set in the programmer top bar Range 1min to 60min Czas postoju pompy cyrkulacyjnej Circulation pump idle time Parameter determines circulation pump idle time operation idle operation idle if pump operation is set in the programmer top dash Range Omin to 60min Temperatura zataczenia pompy cyrkulacyjnej Circulation pump activation temperature Minimum DHW temperature above which the circulation pump may operate Circulation pump is stopped after DHW temperature is reduced by 0 5 C Range 25 C to 60 C Praca auto w trybie recznym Automatic operation in manual mode Parameter enables automatic circulation pump operation in manual mode Range TAK Yes NIE No Tablica dobowa Daily schedule Weekly daily schedule to set time circulation pump operation intervals f Programator Auto Lato Automatic summer programmer If Auto Lato prog Automatic summer programmer mode is set for Tryb Pracy CWU DHW operation mode you can set intervals to activate summer or winter mode Time intervals are defined in Tablica tygodniowa Weekly schedule top dash summer mode bottom dash winter mode g Programator ogrzewania pod ogowego Floor heating programmer It selects floor heating temperature depending on the conditions in the room Programmer requires floor heating temperature sensor installation Programator pod ogowy Floor heating programmer is a
25. cess 8 Reset hase Password Read only user user password user reset Administrator rights user admin password admin 5 5 Data i czas Date and time Time settings ensuring correct programmer operation After selecting Data i czas Date and time a window with time set for the controller is displayed Dala 1 czas zHm Ho H KIE 49 Change time with up and down arrows Select date items with right and left arrows 5 6 Parametry zaawansowane Advanced parameters Used for boiler installation settings Item Parameter Description 1 Typ kot a Boiler type Feeder operation mode combustion algorithm Retorta reczny Retort manual retort feeder manual combustion process Combustion parameters available in Parametry spalania Combustion parameters menu Retorta grupowe Retort group retort feeder semi automatic combustion process Combustion parameters available in Parametry spalania Combustion parameters menu Ttok auto Ram auto ram feeder semi automatic combustion process Combustion parameters available in Parametry spalania Combustion parameters menu Ttok reczny Ram manual ram feeder manual 42 67 Internetowy sterownik kotta z kontrola temperatury spalin e N NS We 27 Item Parameter Description combustion process Combustion parameters available in Parametry spalania Combustion parameters menu Zasy
26. chawa 0 8A 0 8A mieszaj ca 0 8A 0 8A Fig 5 Housing wall with power outputs 3 7 PC connection The PC is connected with cable included The PC shall be fitted with RS232 connector DB9 socket Optional RS232 USB adapter is available 22 67 Internetowy sterownik kotta z kontrola temperatury spalin U SN p We 427 Fig 6 RS232 cable Fig 7 RS232 connector connection Controller shall be connected to the Ethernet with UTP network cable PATCH CABLE with RJ45 plug The controller must be connected to local network switch or router Set IP address mask and default gateway in the controller The options are available in Internet menu Ethernet Fig 8 Ethernet RJ45 connector 4 Controller operation 4 1 Control panel keyboard LCD panel features LCD keys and LED indicators Green LED indicates operation of the devices supplied by the controller Red LED indicates alarm Four arrow keys enable menu navigation and change of value The following function keys are available OK Enter to select operation level settings menu and confirm changes Press OK to select maintenance level or enter settings menu by holding the key for approx 1 sec The second function key is 23 67 Internetowy sterownik kotta z kontrola temperatury spalin UN Sx E ty NS 122 Esc Press to exit the menu cancel selected or set parameters cwu alarm Fig 9 Control panel 4 2 Control panel Maintena
27. ctivated in 40 67 Internetowy sterownik kotta z kontrol temperatury spalin U Parametry zaawansowane Advanced parameters IA Lin WSS Ly We ee Funkcja pompy mieszajacej Mixing pump function Podtogowa Floor heating Item Parameter Description 1 Temperatura dzienna Day Day temperature maintained in the room Range 5 C temperature to 35 C gt Temperatura nocna Night Night temperature maintained in the room Range 5 C temperature to 35 C The parameter determines value by which the temperature in a room with floor heating is reduced to 3 a ote aol start the room heating procedure Range 0 2 C to 5 0 C If temperature is reached floor heating pump switches Czas pracy pompy to cyclic operation mode The parameter determines 4 pod ogowej Floor heating floor heating pump operation time Time set to O stops pump operation time the pump after reaching set floor heating temperature Range Omin to 60min If temperature is reached floor heating pump switches Czas postoju pompy to cyclic operation mode The parameter specifies floor 5 pod ogowej Floor heating heating pump idle time Time set to O results in pump idle time continuous pump operation even if set floor heating temperature is reached Range Omin to 60min A Daily schedule to set time intervals for day and night 6 pac GOPORZ Daly temperature Upper dash day temperature bottom schedule da
28. defined in the next parameter Range 5s to 120s Ilos powtorzen postoju 7 10 podajnika Number of feeder Number of cycles OPERATION SHORT PAUSE in A f sustain mode Range 1 to 5 idle time cycles Moe dmuchawy di Blower power set in sustain mode Range 25 to 11 podtrzymaniu Blower power d 100 in sustain mode Moc dmuchawy w trybie Blower power set in manual mode Range 25 to 12 recznym Blower power in 100 manual mode b Parametry spalania Combustion parameters typ T okowy Ram type grupowy Group Semi automatic combustion process New combustion process control method User may select 6 different power settings for boiler operation User sets minimum and maximum power only Blower power must be defined for selected power settings Histogram facilitates blower power settings available on the controller website Switching between minimum and maximum power is automatic Minimum power is activated below CH hysteresis whereas maximum power is activated if CH temperature falls below double hysteresis 30 67 Internetowy sterownik kotta z kontrola temperatury spalin P U UR NS We 2 Sustain mode is activated 1 C above set temperature Item Parameter Description 1 Minimalna moc kotta Minimum boiler power selected from the range of Minimum boiler power power settings gt Maksymalna moc kotta Maximum boiler power selected fro
29. e eossseskasemesrezetarucperupixbexeBexresgacas cs epe Sex UE 43 5 6 Parametry zaawansowane Advanced parameters ss 43 6 ALANIS E A nA dna bx Seat da ow EEE OWE KA KA eds 46 o NN 48 7 1 Controller software LUpDCIaL8 i a y tree 48 8 SB LES 52 8 1 Controller connection to local network eee nnn 53 8 2 Setting local network parameters in the controller 53 8 3 Website panel in the controller eeeeeeeeee eere 56 8 4 Connecting controller to remote access service uaaaaaaaaaaaaaa1112 61 8 5 Sharing controller with other USEP cccee eee aaa eee teen eens eeaeeenaaes 66 3 67 Internetowy sterownik kotta z kontrol temperatury spalin So PP gt U we KUR 2 q Visit our website http bruli pl http eSterownik pl The websites include Answers to the frequently asked questions FAQ Latest version of bruli pl controller software Latest version of bruli pl controller website PC software enabling update of bruli pl controller software eSterownik pl website developed for bruli pl users provides Remote Access to the controller via Internet if no public IP is available A proxy server allows communication if no public IP address is available And much more 4 67 Internetowy sterownik kotta z kontrol temperatury spalin bruli pl software Version histor
30. e with these directives is safeguarded by respecting the following standards PN EN 60730 2 9 2006 in conjunction with PN EN 60730 1 2002 A1 2008 A2 2009 A12 2004 A13 2005 A14 2006 A15 2009 A16 2009 Ap1 2007 IEC 60730 2 9 2008 Third Edition in conjunction with IEC 60730 1 1999 Third Edition A1 2003 A2 2007 Last two digits of the year in which the CE marking was affixed 10 This declaration does not represent any warranty of the properties within the meaning of the Product Liability Act Safety provisions listed in the User Manual are to be followed According to the Low Voltage Directive LVD devices with the CE mark should be installed and connected according to the user manual and the provisions of the Electromagnetic Compatibility Directive ELEKTROS S STEM qut Edwald Stasiak Kutno 07 10 2010 67 67
31. enance will render the warranty void Assembly and installation works shall be carried out by the service centre or personnel with proper qualifications and authorization in accordance with current regulations and standards Due to the operation safety and mains electromagnetic interferences which may affect operation of the controller and other devices connect the controller to the socket with an earthing pin Do not expose controller to water and excessive humidity resulting in condensation e g rapid ambient temperature changes Do not expose controller to temperature above 45 C and below 5 C In case the auxiliary grate is used for wood or waste firing remove the flue gas sensor from the flue Wiring must be fixed on the entire length and must not contact water jacket or flue gas conduits Disconnect mains plug before connecting disconnecting devices supplied by the controller During the storm the controller must be disconnected from mains The system must be protected with fuses with a correct rating in accordance with current standards and regulations Do not install the controller with damaged housing or wires All repairs must be carried out by an authorized service centre In other case the warranty is void Flue gas sensor requires cleaning at least once a month The flue gas must be fitted in the middle of the flue diameter right behind 17 67 Internetowy sterownik kotta z kontrol tem
32. er is reduced by the value set for Temperatura CO obni ona Reduced CH temperature parameter CH pumps operation may also be defined Parametry zaawansowane Advanced parameters when CH temperature reduction does not cause temperature decrease in the room An internal temperature sensor must be connected to activate the option Termostat Thermostat CH set temperature set manually on the control panel In case the thermostat contacts are open CH set temperature will be reduced by value set for Temperatura CO obni ona Reduced CH temperature CH pumps operation may also be defined Parametry zaawansowane Advanced parameters when CH temperature reduction does not cause temperature decrease in the room 3 Tryb CWU DHW mode Parameter for setting DHW pump operation mode Zima Winter normal DHW pump operation in winter mode Both CH pump central heating and DHW pump domestic hot water tank are active Lato Summer DHW pump operation in summer mode CH pump is stopped no central heating AutoLato t zew Auto summer external temperature automatic summer mode with external temperature setting in normal mode Depending on external temperature external temperature sensor is required the controller will automatically switch from Lato Summer to Zima Winter mode and vice versa Activation threshold for switching summer winter mode is available in the advanced parameters menu Temp zewnetrzna dla Aut
33. er locked deactivated feeder motor plug etc 7 PC software The controller is compatible with a PC free bruli pl updater provides controller software updates The software can be used to update bruli pl controller website The website is stored on SD memory card The PC is connected with cable included USB RS232 adapter is available for PCs without RS232 cable The software is available on http bruli pl 7 1 Controller software update Ensure the following to update the bruli pl controller software PC with Windows OS serial port or USB RS232 adapter RS232 cable delivered with a controller latest software downloaded from http bruli pl Wsparcie Support tab 6 Controller updater Due to continuous development and improvements of bruli pl controller test 47 67 Internetowy sterownik kotta z kontrola temperatury spalin NU A SS Z NB Y 5 lt gt 22 Z software builds are regularly made available Test builds include numerous amendments and new functions Controller updater software is available on http esterownik pl forum posty 40 To start software update in the controller connect the PC with RS232 cable RS232 USB adapter is available if RS232 port is not available Fig 11 RS232 connector Fig 10 RS232 cable Start the updater software bruliUpdater_X X X X exe To start the controller software update select RS232 communication port to which the controller is co
34. ik kotta z kontrol temperatury spalin NS 7 03 Z ty NS 2 7 Try again if the first attempt did not succeed Update process does not allow controller failure due to software update Update website after the software update is completed Use the same software as used for the controller software update bruliUpdater pl X X X X exe and select Aktualizacja strony www Website update tab top Updater bar Connect the controller to the local Ethernet with RJ45 cable The controller is assigned with a unique IP address mask and gateway detailed description is indicated in item Setting local network parameters in the controller Fill in the fields in the updater Adres IP IP address enter controller IP address Enter administrator login and password with proper rights on the website default login admin password admin Click the button Sprawdz po czenie Check connection Connect the controller and click Aktualizuj strone WWW w sterowniku Update website in the controller Exit the updater after the update is completed 50 67 Internetowy sterownik kotta z kontrola temperatury spalin Aktualizacja firmware Aktualizacja strony WWW Aby rozpocz aktualizacj nale y wpisa poprawny adres sterownika oraz poprawny login i has o administratora Je eli sterownik jest prawid owo pod czony pojawi si informacja o uzyskaniu po czenia Wi cej informacji o po czeniu
35. ime may not be too short excessive combustion rate left side of the histogram or too long low combustion rate right side of the histogram 15 67 Internetowy sterownik kotta z kontrola temperatury spalin Distribution of the rectangles on the histogram shows the operation of a group combustion algorithm If high rectangles are on the right side of the histogram it means that the algorithm does not detect fuel combustion in set time and indicates low air supply The data can be used to set the blower power in the group combustion process it will not replace observation of a furnace soot and coal deposits Histogram is a visualisation of group combustion algorithm only Moc dmuchawy dla 16kW 62 Moc dmuchawy dla 20kW 96 82 Moc dmuchawy dla 25kW 99 2 Histogram dla mocy MIN Histogram dla mocy MAX dli il Fig 2 Histograms on the website 1 4 Specification Power SUD oni O ia 230V 50Hz Protection Falli ese wia AGGA M RES IP40 Electrical protection class I Allowable ambient temperature 5 C to 45 C no condensation Feeder circuit load up to 0 8 A Blower circuit load ees up to 0 8A Pump circuit IDOL ics soie arras up to 0 8A FIBRE ata EET 4A Internetowy sterownik kotta z kontrola temperatury spalin 2 Safety Read the warranty terms and conditions and User manual before installation Incorrect installation operation and maint
36. installation diagrams are displayed in the main page Temperature sensor readouts are updated on line In the manual operation mode the devices can be switched ON OFF by clicking on the feeder blower and pump icon Select TRYB AUTOMATYCZNY Automatic mode to change the operation mode Tena ic li TEE bruli pl Wyloguj 39 0 C Temperatura 384 Y LI AL TRYB AUTOMATYCZNY Reg kotta Pogodowy Reg wew Reg wew Pokojowy Tryb CWU Zima Temperatura 1 9 C zewn trzna Przewidywana data zasypu 2013 02 27 13 54 lene _72 2 C 2 C 38 2 C Temperatura 404 7 214904 emama 121 0 V errerrrerrrrrrrrrrrr 18 3904 eed 5 0 V 7 v v VY 30 7oC Ke sz Temp podajnika 29 sd ani OES E TS z bruli pl 0 1 17 14 www 0 1 9 16 Dostep tylko do odczytu Alarmy Brak alarm w Fig 18 bruli pl controller main website window All parameters set on the LCD panel are also available on bruli pl controller website Parameters can be changed by users with administrator rights Time and date Ethernet parameters and advanced parameters can be set and all temperature sensors can be calibrated via website 56 67 Internetowy sterownik kotta z kontrol temperatury spalin Minimalna temperatura CO C 36 s Funkcja pompy mieszaj cej Mieszaj ca 2 Maksymalna temperatura
37. l d 4 Pomoc A d Regulamin Copyright 2010 ELEKTRO SYSTEM s c ul Sienkiewicza 25 99 300 Kutno Zako czono Fig 27 Controller sharing y 6 Enter login or email of the user you want to share the controller with in Dodaj u ytkownika Add user field Select user rights Tylko podgl d Read only only parameter readout is possible user may not change any parameters or control the controller Pe ne prawa Administrator rights read and store parameters user may control the boiler and modify all controller parameters 7 Users with specific rights can find the controller in Twoje sterowniki Your controller tab 66 67 Internetowy sterownik kotta z kontrola temperatury spalin p Sin x gt Ly NS ty ND lt 2 Declaration of Conformity ELEKTRO SYSTEM s c with registered place of business at ul Sienkiewicza 25 Kutno declares that the product identified as bruli pl Internet boiler controller is in conformity with the provisions of the following European directives e Directive 2006 95 EC of the European Parliament and of the Council on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits e Directive 2004 108 EC of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC Complianc
38. lected IP address Select Internet menu on the control panel press and hold OK press up and down to select Internet and press OK enter adres IP IP address brama gateway and maska mask 8 Connect the controller with twisted pair with RJ45 connector to a local network Ethernet Fig 16 Ethernet connector in bruli pl controller 9 The controller shall automatically connect to the network To enter Panel 54 67 Internetowy sterownik kotta z kontrol temperatury spalin WWW Website panel enter previously set controller IP address in the internet browser 8 3 Website panel in the controller Default sign in parameters User with limited access read only user user password user User with administrator rights parameter change user admin password admin Sign in parameters can be changed via website see Ustawienia Settings gt Internet Internet gt X 192 168 0 7 gt 3 Goode 2 s Wczytywanie L Podaj nazwe uzytkownika i hasto x u Witryna http 192 168 0 7 da podania nazwy u ytkownika i has a Komunikat witryny Podaj haslo do sterownika U ytkownik admin Has o eccce Anuluj OK Fig 17 Signing in on bruli pl controller website We recommend Mozilla Firefox or Google Chrome 55 67 Internetowy sterownik kotta z kontrola temperatury spalin CH and DHW
39. m the range of Maximum boiler power power settings 3 Moc dmuchawy dla 8kW Blower power for selected 8 kW power Range 25 Blower power for 8 kW to 100 4 Moc dmuchawy dla 12kW Blower power for selected 12 kW power Range Blower power for 12 kW 25 to 100 5 Moc dmuchawy dla 16kW Blower power for selected 16 kW power Range Blower power for 16 kW 25 to 100 6 Moc dmuchawy dla 20kW Blower power for selected 20 kW power Range Blower power for 20 kW 25 to 100 7 Moc dmuchawy dla 25kW Blower power for selected 25 kW power Range Blower power for 25 kW 25 to 100 8 Moc dmuchawy dla 30kW Blower power for selected 30 kW power Range Blower power for 30 kW 25 to 100 Czas postoju w 9 podtrzymaniu Idle time in dae un time in sustain mode Range 3min to sustain mode Czas pracy w podtrzymaniu Fuel feeding time in sustain mode Range 2s to 10 Operation time in sustain 180s mode Short feeder pause idle time in sustain mode Fuel feeding cycle in sustain mode is carried out in the following stages Kr tka przerwa w OPERATION SHORT PAUSE OPERATION SHORT 11 podtrzymaniu Short pause in pause sustain mode DN Cyclic operation allows complete fuel combustion in sustain mode The number of cycles may be defined in the next parameter Range 5s to 120s Ilos powtorzen postoju E E 12 podajnika Number of feeder Number of cycles OPERATION SHORT PAUSE in sustain mode Range 1 to 5 idle ti
40. me cycles moe dmuchawy T Blower power set in sustain mode Range 25 to 13 podtrzymaniu Blower power 100 in sustain mode E Moc dmuchawy w trybie 5 5 14 r cznym Blower power in pond power set in manual mode Range 25 to manual mode 31 67 Internetowy sterownik kotta z kontrola temperatury spalin c Parametry spalania Combustion parameters typ Tlokowy Ram type auto Automatic Group combustion in ram feeder consists in calculating the fuel feeding time based on the controllers algorithm User enters an average ram time interval and the controller operates based on this value The interval range must be used for process control otherwise the time would be from zero to infinity User sets mean idle time for the feeder Signal from the ram feeder limit switch is connected to the KONT terminal of the controller available for ram feeder No operation of Alarm zewn trzny External alarm is Item Parameter Description 1 UNE mena Bea aa seeke Ram operation time Range 10s to 360s gt Czas postoju w grzaniu Idle Interval between fuel feeding in heating mode time in heating mode Range 10s to 3600s 3 Moc dmuchawy w grzaniu Blower power set in heating mode Range 25 to Blower power in heating mode 10096 P y i Determines when the heating mode is activated 4 ao grzania Peaking after sustain mode Range Dmuchawa podajnik feeder blower Tylko dmuchawa bl
41. nce level After connecting power supply to the controller software version screen is displayed The main screen includes information on measured and set CH and DHW temperature if DHW option is active and DHW sensor connected The main screen also shows information on boiler operation mode top line e R manual operation e C automatic operation temperature set by CH programmer P automatic operation temperature set by weather compensation programmer K room regulator active e T room thermostat active 24 67 Internetowy sterownik kotta z kontrol temperatury spalin At DHW temperature bottom line in manual mode R indication is showed manual mode In the automatic mode the following marks indicate DHW temperature adjustment mode e N winter mode normal DHW pump operation e P DHW priority mode DHW pump priority e L summer mode domestic hot water pump operation only Z automatic summer temperature mode switching winter summer mode depending on external temperature e G automatic summer programmer mode switching winter summer mode depending on programmer setting Set temperature Measured temperature Temperature reduction Temperature setting for CH regulator The main screen shows data for boiler operation at reduced temperature It is indicated by a down arrow next to CH and DHW set temperature No arrow indicates normal temperature Disconnecting DHW
42. net access is available via Zdalny dostep Remote access service Depending on Internet provider and equipment Service type Internet connection Controller connection USB modem Purchase router with ADSL DSL ADSL link modem Neostrada Net24 etc Router e g Livebox with OK free RJ45 connector GPRS UMTS HSDPA USB modem Purchase GPRS UMTS HSDPA connection compatible router iPlus blueconnect orange s id Online WiFi modem Purchase Access Point Cable link Cable modem with a single h chello Vectra Toya etc RJ45 output Purchase switch router Modem A Pe ve Purchase switch router Other internet provider Switch Router with free RJ45 OK socket WiFi modem Purchase Access Point No Internet access i sd k gt A access via local network no local networ no remote access service ony Switch a no remote access service Set three network parameters adres IP IP address brama gateway and maska mask 8 2 Setting local network parameters in the controller 1 Click Start and select Uruchom Run 52 67 Internetowy sterownik kot a Q 2 kontrol temperatury spalin P 4 Ww NS NS 2 gt e 2 Enter cmd and click OK 3 Console is opened Uruchamianie i 2 xi 5 wpisz nazw programu folderu dokumentu lub zasobu t internetowego a zostanie on otwarty przez system Windows Otw rz s y Anuluj Przegl daj Fig 14 Run window in Windows
43. nie wytaczenie sterownika Data Alarm zdarzenie 2010 03 16 12 05 16 Wy czenie sterownika 2010 03 16 12 07 15 Zalaczenie sterownika 2010 03 16 12 07 22 Blad pamieci EEPROM wystapienie alarmu 2010 03 16 12 07 22 B d pami ci EEPROM potwierdzenie alarmu 2010 03 16 12 07 22 Wylaczenie sterownika 2010 03 16 12 07 29 Zataczenie sterownika 2010 03 16 12 08 32 Tryb automatyczny 2010 03 16 12 08 35 Tryb r czny 2010 03 16 12 12 11 Wy czenie sterownika 2010 03 16 12 12 18 X Za czenie sterownika 2010 03 16 12 43 32 Tryb automatyczny 2010 03 16 13 43 32 _ Wygaszenie kot a wyst pienie alarmu 2010 03 16 13 43 32 Tryb r czny 2010 03 23 12 12 23 Tryb automatyczny 2010 03 23 12 12 37 Tryb r czny 2010 03 23 12 12 44 Tryb automatyczny 2010 03 23 12 20 49 Tryb r czny 2010 03 30 10 34 53 Wygaszenie kot a potwierdzenie alarmu Dost p odczyt i zapis Alarmy Brak alarm w Fig 22 Alarm and event window 8 4 Connecting controller to remote access service Zdalny dost p Remote access service is intended for users who purchased the controller and want easy access to boiler parameters via Internet Service configuration is easy and does not require special experience The service helps with the following issues no public IP address mobile cable network users etc no fixed IP address ADSL users etc problems with router configuration 60 67 Internetowy sterownik kotta z kontrola temperatury spalin
44. nnected For RS232 USB adapter check the port in Windows OS Device manager If the controller is connected correctly information on connection is displayed bottom left corner of the Updater window Connect the controller and press Aktualizuj oprogramowanie Update software Wait for the update to complete information in Updated dialog box 48 67 Internetowy sterownik kotta z kontrol temperatury spalin uL WO CJ KARE ZES AAA Aktualizacja firmware Aktualizacja strony www Aby rozpocz programowanie nale y wybra odpowiedni port komunikacyjny RS232 Je eli sterownik jest prawid owo pod czony pojawi si informacja o uzyskaniu po czenia Wi cej informacji o po czeniu mo na uzyska na stronie bruli pl w dziale FAQ Wersja oprogramowania 0 1 17 14 Aktualizuj oprogramowanie Pot COM5 Wersja sterownika lt nie odczytana gt Status Postep RS232 Brak potaczenia Fig 12 Software update Caution In case of update error update is stopped and Loading message is displayed on the controller 1 Turn off the controller 2 Run updater again 3 Select RS232 port if adapter is used disconnect and reconnect USB 4 Press software update button 5 Status will change to Oczekiwanie na sterownik Waiting for controller 6 Switch the controller ON 7 Update process will start 49 67 Internetowy sterown
45. o Lato External temperature for automatic summer mode AutoLato prog Automatic summer 35 67 Internetowy sterownik kotta z kontrola temperatury spalin Item Parameter Description programmer switches Lato Zima Summer Winter mode in accordance with defined times in AutoLato prog Automatic summer programmer mode available in Programatory Programmers gt Programator AutoLato Automatic summer programmer Priorytet CWU DHW priority Once activated this function enables additional water heating in DHW tank If this function is active when additional water heating is required CH and floor heating pump are stopped and DHW pump operates It is also possible to increase CH set temperature by CH temperature increase parameter Parameter available in Ustawienia Zaawansowane Advanced settings Podbicie temp CO CH temperature increase Range TAK Yes NIE No Temperatura CWU obnizona Reduced DHW temperature Temperature value by which DHW set temperature is reduced display 4 if low temperature is set in the weekly schedule Range 0 C to 20 C Temperatura CO obni ona Reduced CH temperature Temperature value by which CH set temperature is reduced display 4 if low temperature is set in the weekly schedule or if connected thermostat opens the contact Range 0 C to 30 C Przywr c ustawienia serwisowe Restore service settings Possibility to restore default set
46. omestic hot water temperature Setting ccccecceeeeeeeeeee eee eeeeennaes 28 2 5 FUNCIONA fuel Chal aoi GA odc O AEGEE DEO i O htt Emi E 29 5 Controller prograMMiNgssisesisisreisi terea kipen keriari deei OJ AO OG En puppi 29 5 1 COMBUSTION ParGMETE aoc abc 29 a Parametry spalania Combustion parameters typ Ttokowy Ram type r czny MAMUG aaa OGAE GOES OEG GE OEG A AEGEE 30 b Parametry spalania Combustion parameters typ T okowy Ram type grupowy rol za oka OE OP A OOO ai 31 c Parametry spalania Combustion parameters typ T okowy Ram type auto Automatic ivonne 32 d Parametry spalania Combustion parameters typ Ttokowy Ram type reczny Manual cocaina O o AP A ARR AG da d 33 e Parametry spalania Combustion parameters typ Zasypowy Hopper CYPE iaa AG kob O AA AMNES 34 3 2 Meer Detal tib OL Simao rar ica EE REN Ud duc GG 25 3 3 PROGIANIIMEE Perret vos dd N43 Sad PE aces 37 a Programator CO CH programmer aussi sek O dA CAE EG 38 b Programator CWU DHW programmer cssseee mn 39 c Programator pogodowy Weather compensation programmer 39 d Programator pokojowy Room programmer eene 39 e Programator pompy cyrkulacyjnej Circulation pump programmer 40 f Programator Auto Lato Automatic summer programmer 41 2 67 Internetowy sterownik kotta z kontrola temperatury spalin Loy QW 5 5 Data i czas Date and tim
47. on 1 Regulator temperatury kotta Boiler temperature regulator Central heating temperature at the boiler outlet Programator CO CH programmer CH set temperature is set manually on the control panel and reduced temperature is set based on programmed weekly schedule Programatory Programmers gt Programator CO CH programmers gt Tablica dobowa Daily schedule and Temperatura CO obnizona Reduced CH temperature parameter Programator CO CH programmer CH set 34 67 gt ey 2 lt yy ty NO Internetowy sterownik kot a z kontrol temperatury spalin NU SS SS 22 Z Item Parameter Description temperature is set based on weather compensation programmer algorithm and reduced temperature is set based on programmed weekly schedule Programatory Programmers Programator pogodowy Weather compensation programmer gt Tablica dobowa Daily schedule and Temperatura CO obni ona Reduced CH temperature parameter Regulator temperatury 2 wewn trznej Internal temperature regulator Parameter for setting internal temperature Programator pokojowy Room thermostat Room thermostat will maintain set temperature in the room day or night depending on weekly schedule If room temperature exceeds value set in Programatory Programmers Programator pokojowy Room thermostat gt Temperatura dzienna lub nocna Day night temperature CH temperature at the boil
48. ontroller E g connecting DHW temperature sensor activates DHW pump operation and connecting external temperature sensor allows automatic use of a weather compensation programmer etc The sensors must be connected to the controller in accordance with the markings on the printed circuit board by leading the sensor cable via a correct cable gland description on the housing KTY81 210 type and PT 100 type for flue gas temperature sensors are used If the sensor is not connected it is signalled with dashes by the sensor marking Port Ethernet MIT dm Hue Port RS232 Karta SD Panel LCD Termik CO Czujnik CO Czujnik podajnika Czujnik T powrotu Czujnik CWU Czujnik zewn trzny Czujnik wewn trzny Czujnik pod og wki Czujnik T spalin Termostat pokojowy Alarm zewn trzny Fig 4 Terminal strip for sensors The controller may detect damaged sensors Disconnect mains plug before connecting disconnecting sensors to the controller and disconnect mains plug each time 20 67 Internetowy sterownik kotta z kontrola temperatury spalin X m 7 SS A Ny NS Ly NS CASE 3 4 Connecting room thermostat Room thermostat external device e g Auraton must be connected to the controller board to TERM terminals The thermostat connected to the controller shall be fitted with potential free contact In case the room thermostat is connected CH temperature is set by switching the contacts on the boiler daily
49. ower only Czas postoju w F 5 podtrzymaniu Idle time in Feeder idle time in sustain mode Range 3min to 360min sustain mode 6 Czas dopalania wegla Coal Blower operation time after fuel charge sustain after combustion time mode Range 5s to 360s 7 Krotnos podawania Feed Determines number of cycles in sustain mode before multiplicity fuel charge Range 0 to 20 8 lr Nd RA Parameter determines number of blower p rzy cycles in sustain mode Range 0 to 20 sustain mode dur dHiucHawy rd Blower power set in sustain mode Range 25 to 9 podtrzymaniu Blower power 5 f 10096 in sustain mode Moc dmuchawy w trybie 10 recznym Blower power in Blower power set in manual mode Range 2596 to 10096 manual mode d Parametry spalania Combustion parameters typ Tlokowy Ram type reczny Manual Combustion process for ram feeder is set manually All combustion parameters 32 67 Internetowy sterownik kotta z kontrol temperatury spalin P NA U We 2 are user defined Signal from the ram feeder limit switch is connected to the KONT controller terminal No operation of Alarm zewnetrzny External alarm is available for ram feeder Item Parameter Description 1 did mena Hoke Sn Stroke Ram operation time Range 10s to 360s 2 Czas postoju w grzaniu Idle Interval between fuel feeding in heating mode time in heating mode Range 10s to 3600s
50. peratury spalin the boiler output In case the sensor cable length exceeds 5 m shielded cable pairs are recommended Cable shield must be connected to PE terminal on the controller side only 18 67 Internetowy sterownik kotta z kontrola temperatury spalin P UE Y a SS CAES 3 Installation Assembly and installation works shall be carried out by the service centre or personnel with proper qualifications and authorization in accordance with current regulations and standards 3 1 Environmental conditions Do not expose controller to water and excessive humidity resulting in condensation e g rapid ambient temperature changes Do not expose controller to temperatures above 45 C and below 5 C 3 2 Installation of a control panel OAn LCD housing is snap fastened Lead a cable through a gland in a bottom part of the LCD housing Connect on end of the cable to a screw terminal on the display board and lead the other end through the gland in the controller housing and connect to a suitable terminal Connect in accordance with the following colour codes GND white B yellow A green e 12V brown Recommended cable LIYYAx0 25mm Fig 3 Control panel 19 67 Internetowy sterownik kotta z kontrol temperatury spalin 3 3 Connecting measuring sensors Activation of connected devices and controller functions is automatic and depends on connection of temperature sensors to the c
51. powy Hopper combustion at an emergency grate Combustion parameters available in Parametry spalania Combustion parameters menu Minimalna temperatura CO Minimum CH temperature User defined CH set temperature limit This parameter also defines CH temperature at which CH pump is activated CH pump activation threshold reduced by 2 C from set value CH pump deactivation 4 C below set value Range 35 C to 60 C Maksymalna temperatura CO Maximum CH temperature User defined CH set temperature limit This parameter also defines CH temperature at which CH pump is activated e g when room thermostat algorithm forces CO pump to deactivate Range 65 C to 80 C Histereza CO CH hysteresis Central heating temperature hysteresis Temperature below set temperature minus Histereza CO CH hysteresis switching to heating mode Range 0 2 C to 5 0 C CH pump operation mode for internal regulator Parameter determines CH pump operation with active room thermostat thermostat After room temperature is reached CH pump may operate in three 3 modes Ci g a Continous always ON reduced CH set temperature after reaching set temperature in the room CH pump does not stop Cykliczna Cyclic CH pump operates in cyclic mode with set operation idle time intervals parameter 5 and 6 after reaching set temperature in the room Wytaczona OFF CH pump is stopped after reaching set
52. ram stroke Amended Histereza CWU DHW hysteresis parameter resolution changed to 0 1 deg Amended Removed 45 days limit for next fuel charge Amended Improved SD card data readout Version 0 1 17 2 Added Blower speed reduced to 25 9 67 Internetowy sterownik kotta z kontrola temperatury spalin Added new ram feeder parameter Krotno podawania Feed multiplicity range 0 20 Version 0 0 1 16 Added Feeder operation time counter Feeder operation time is displayed on the control panel in position 4 press 4 arrow down 3x CP POD field Hold gt right arrow or left arrow to reset the time after fuel charge to the hopper Time may also be reset via our website Ustawienia u ytkownika User settings Wyzeruj Reset button Added Indicates low fuel level in the hopper based on determined feeder operation time Feeder operation time may be set via website Parametry u ytkownika User parameters Czas do opr nienia zasobnika min Time to empty hopper min field Added Logging new fuel batch info in alarms and events Added Anticipated date of the next fuel charge Algorithm calculates date based on defined hopper emptying time The date is displayed after the next charge and feeder operation time reset Added New advanced parameters Tryb pracy pompy CO CH pump operation mode Czas pracy pompy CO CH pump operation time Czas postoju pompy CO dla regulatora pokojowego i termo
53. rameter Czas wyrzutu paliwa z podajnika gdy aktywny alarm Zap on paliwa Fuel removal time from the feeder with Fuel ignition alarm active Added parameter change graph on the website Amended Alarm Zewn trzny External Alarm error in Retortowy auto Retort auto and Zasypowy Hopper mode 6 67 Internetowy sterownik kotta z kontrola temperatury spalin SS SP we UN 27 EN Version 0 1 17 10 New group combustion algorithm for retort boiler Retortowy auto Retort auto New group combustion algorithm for boilers with ram feeder Ttokowy auto Ram auto Boiler with hopper feeder compatibility emergency grate combustion Added parameter Ustawienia Zaawansowane Algorytm wygaszenia kotta Nieaktywny tylko grzanie tylko podt aktywny Settings Advanced Boiler put out algorithm Not active heating only sustain only active Parameter determines boiler put out analysis method Added parameter Ustawienia Uzytkownika Priorytet CWU Settings User DHW priority separate DHW priority function mode removed from Tryb pracy CWU DHW operating mode Added emergency CH pump activation above set temperature Ustawienia Zaawansowane Maksymalna temperatura CO Settings Advanced Maximum CH temperature Added new alarm Wysoka temp podajnika High feeder temperature activated 5 C below Max temp podajnika Max feeder temperature Added new parameter Programatory Programator p cyrkulacyjnej Temp
54. rogramming Controller settings can be changed via control panel To access the settings press and hold OK for 1 second Select the item and press OK 28 67 Internetowy sterownik kotta z kontrola temperatury spalin P WEJ X We Aa 5 1 Combustion parameters Parametry spalania Combustion parameters menu items are changed depending on combustion algorithm selected in the advanced parameter menu Typ kot a Boiler type e Retorta reczny Retort manual retort feeder manual combustion process Retorta grupowe Retort group retort feeder semi automatic combustion process Ttok auto Ram automatic ram feeder semi automatic combustion process Tlok auto Ram manual ram feeder manual combustion process Zasypowy Hopper combustion at emergency grate with feeder stopped Select an item and press OK Select item with up or down arrow Press OK to edit item Press up and down arrow 11 to change value Press OK to confirm Press ESC to cancel and exit a Parametry spalania Combustion parameters typ Ttokowy Ram type reczny Manual Manual combustion process All combustion parameters are set by the user Item Parameter Description Regulator temperatury The function limits flue gas loss by reducing blower 1 spalin Flue gas temperature power at exceeded flue gas temperature Range regulator Inactive Active Maximum flue gas temperature maintained by the flue gas
55. roup repeating of fuel feeding and short feeder idle time cycles following a long interval to complete combustion of the previous fuel batch and the moment of complete combustion is determined based on flue gas temperature trend analysis 14 67 Internetowy sterownik kotta z kontrol temperatury spalin NS WES UN lt gt e e D NS ez Fig 1 t EE AT TT FT f EN n tp ts td Fig 2 td gt gt ts ts gt gt ts tp czas pracy podajnika ts ts czasy postoju podajnika td czas d ugiej przerwy w podawaniu Fig 1 Comparison of group and standard combustion processes 1 3 Group combustion histogram Histogram is a graphical representation of the distribution of data It is shown as adjacent rectangles on the coordinate axis The rectangle sizes are determined by class intervals see distribution series with height determined by the size In this case feeder idle times with 10 s resolution are grouped on the X axis The higher the rectangle the more often the specific idle time have occurred Shorter idle times are grouped on the left side of the histogram and longer idle times are grouped on the right side Idle times depend on blower rate the higher the blower speed the faster the combustion process rectangles on the left side of the histogram the lower the blower speed the slower the combustion process rectangles on the right side of the histogram Idle t
56. s Czas pracy pompy CO dla reg wew CH pump operation time for internal temperature regulator and Czas postoju pompy CO dla reg wew CH idle time for internal temperature regulator The settings also apply to active thermostat Item Parameter Description 1 Temperatura dzienna Day Day temperature maintained in the room Range 5 C temperature to 35 C gt Temperatura nocna Night Night temperature maintained in the room Range temperature 5 C to 35 C The parameter determines value by which the internal 3 Histereza Hysteresis temperature is reduced to start the room heating procedure Range 0 1 C to 2 0 C Tablica dobowa Daily Daily schedule to set time intervals for day and night 4 temperature Upper dash day temperature bottom schedule dash night temperature Teme dzienna Temm NOCNA zl C ir E 39 67 Internetowy sterownik kotta z kontrola temperatury spalin NS s P 7 NS LY WO e Programator pompy cyrkulacyjnej Circulation pump programmer In case of DHW circulation pump activation it is possible to set time intervals for pump activation Time intervals are defined in Tablica dobowa Daily schedule top dash pump ON bottom dash pump OFF Item Parameter Czas pracy pompy cyrkulacyjnej Circulation pump operation time Description Parameter determines circulation pump operation time operation idle operation idle if pump oper
57. s depend not only on its origin a coal mine but also on the specific coal bed Coal fuel combustion in automatic boilers is a stochastic process In commonly used solutions fuel feeding and combustion are considered as continuous processes It means that the feeder operates in regular and 13 67 Internetowy sterownik kotta z kontrol temperatury spalin WS ROS SS 7 Li By SS 22 ss repeatable operation idle cycles and its power changes depending on operation and idle time ratio which does not affect repeatability The disadvantages of continuous fuel feeding and combustion processes include issues with fuel to air ratio due to a stochastic nature of the combustion process and the fact that feeding fuel batches in small intervals does not allow complete assessment of the combustion process Significant increase in fuel feeding interval must be related with significant increase in batch feeding time to reach required power causing temporary incomplete combustion in form of a smoke Based on the combustion process testing in automatic solid fuel boilers fuel batching and therefore impulse discrete combustion process allows to asses if the combustion process of a previous batch been completed Treating the fuel batching process and therefore the combustion process not as a continuous but as an impulse process is revolutionary innovation Realization of a new control method consists in g
58. sh night temperature 5 4 Internet It enables parameter setting to connect with the controller via Internet It requires configuration of appropriate parameters Item Parameter Description 1 Adres IP IP address Controller IP address as displayed in the local network 2 Maska Mask Subnet mask used in a local computer network 3 Brama Gateway The default gateway used in a local computer network Shall the controller connect with a remote server Remote server enables controller connection via Zdalny serwer Remote website to change parameters view graphs and to 4 carry out general controller maintenance Public IP server address is not required for the proxy server More on http eSterownik pl Zdalny dostep Remote access tab 5 Adres serwera Server Proxy server IP address Server address is always address available on http eSterownik pl during registration of 41 67 Internetowy sterownik kotta z kontrola temperatury spalin Parameter Description a new controller Zdalny dost p tab Proxy server port Server port is always available 6 Port serwera Server port onhttp eSterownik pl during registration of a new controller Zdalny dost p tab Unique controller identifier Identifier is generated 7 Identyfikator Identifier automatically during registration of a new controller onhttp eSterownik pl website Zdalny dost p tab Setting default passwords for website ac
59. statu CH pump idle time for room thermostat and thermostat Added Two new advanced setting parameters Auto Lato Automatic summer mode ON OFF and Temp zew dla trybu Auto Lato External temperature for Automatic summer mode automatic switching to LATO Summer mode after set external temperature is exceeded Added New user parameter Regulator temp wewn trznej Internal temperature regulator to select temperature adjustment in the room Wy czony Off Prog Pokojwy Room thermostat Termostat Thermostat Changed Zadawanie temperatury Temperature setting parameter to Regulator temperatury kot a Boiler temperature regulator Select Prog CO CH thermostat Prog Pogodowy Weather compensator Changed Extended CH and DHW hysteresis setting from 0 2 deg Changed Other feeder blower parameters extended EEPROM memory reorganisation 10 67 Internetowy sterownik kotta z kontrol temperatury spalin U My Ws 27 Amended CH pump operation algorithm Amended Mixing pump operation algorithm Amended Setting preset temperature for weather compensator with 1 deg step Version 0 0 1 14 Improved communication with Zdalny Dostep Remote access service Amended error causing Wysoka temp spalin High flue gas temperature alarm Added communication frame for reading all required parameters during website loading Extended parameter range Feeder operation idle time Version 0 0 1
60. t 34 Item Alarm name Description Activation of thermal overload relay protection 1 Termik CO CH thermal against water boiling in the boiler After alarm occurs overload relay wait until the temperature is reduced below 50 C to acknowledge the alarm Temp CO gt 90 C CH 5 2 temp gt 90 C 90 C exceeded on the boiler 3 Uszk c CO CRZSEMSOT CH sensor failure failure 4 Uszk cz CWU DHW sensor DHW sensor failure failure 5 Uszk z powrotu Retum Damaged return sensor sensor failure Uszk cz wew Internal 6 f Internal sensor failure sensor failure Uszk cz zew External 7 External sensor failure sensor failure 8 USER e podajnika roedor Feeder sensor failure sensor failure 9 O spalin Moe gas Flue gas temperature sensor failure temp sensor failure 10 uszk pod ogowki egr Floor heating sensor failure heating sensor failure Fuel ignition in the feeder exceeding set temperature in the feeder set Czas wyrzutu Tb qeuprom paliwa Fuel igmio paliwa min Fuel removal time parameter for this alarm Excessive feeder temperature indicates high feeder 12 Wysoka temp podajnika temperature without stopping the feeder If High feeder temperature temperature on the feeder increases by 5 C Zapton paliwa Fuel ignition alarm is activated Boiler is put out alarm in sustain and heating mode Alarm is activated Kociot wygaszony Boiler in heating mode
61. temperature regulator Exceeding temperature will result in blower output reduction Range 90 C to 500 C Minimum power at which the blower rate is reduced Maksymalna temperatura 2 spalin Maximum flue gas temperature Minimum blower power for flue 3 at flue gas temperature regulator active Range gas regulator 25 to 100 4 Czas pracy w grzaniu Fuel feeding time in heating mode Range 2s to Operation time in heating 180s 29 67 Internetowy sterownik kotta z kontrola temperatury spalin e U AUR ODR Parameter Description mode 5 Czas postoju w grzaniu Idle Feeder idle time in heating mode interval between time in heating mode subsequent fuel batches Range 1s to 600s 6 Moc dmuchawy w grzaniu Blower power set in heating mode Range 25 to Blower power in heating mode 100 Czas postoju z i Feeder idle time in sustain mode Range 3min to 7 podtrzymaniu Idle time in 360min sustain mode Czas pracy w podtrzymaniu Fuel feeding time in sustain mode Range 2s to 8 Operation time in sustain 180s mode Short feeder pause idle time in sustain mode Fuel feeding cycle in sustain mode is carried out in the following stages Kr tka przerwa w f OPERATION SHORT PAUSE OPERATION SHORT 9 podtrzymaniu Short pause in pause sustain mode mE Cyclic operation allows complete fuel combustion in sustain mode The number of cycles may be
62. temperature sensor from the controller deactivates DHW pump A row of dashes next to DHW description indicates no active DHW option The sensors must be disconnected with the controller OFF 25 67 Internetowy sterownik kotta z kontrola temperatury spalin At the maintenance level the temperature measured by the active sensor can be verified Press up and down arrows to scroll Item Symbol Description 1 CO CH CH temperature measured and set 2 CW DHW DHW temperature measured and set T WEW Internal Internal temperature 3 temperature T ZEW External External temperature 3 temperature 5 POWROT Return Return temperature 6 SPALINY Flue gas Flue gas temperature T POD Feeder Feeder temperature temperature A CP POD Feeder Feeder operation time operation time 9 T PODLG Floor Floor heating temperature heating temperature 4 3 Controller operation modes The controller has two operation modes automatic and manual Manual mode is used for lighting off the boiler a Manual mode Manual mode can be selected via control panel at the maintenance level or via www browser To switch the mode on via control panel select Tryb Pracy Operation mode with left right arrow and select Tryb Pracy lt reczny gt Operation mode lt manual gt After selecting manual mode all devices supplied by the controller may be switched ON OFF Hold ESC to switch to manual mode 26 67
63. tings stored by the service centre Range TAK Yes NIE No Przywr c ustawienia fabrycznie Restore factory settings Possibility to restore default controller settings Range TAK Yes NIE No 5 3 Programmers Programmers facilitate and automate temperature settings based on a daily schedule and user requirements Available programmers e Programator CO CH programmer e Programator CWU DHW programmer e Weather compensation programmer e Room temperature programmer e Programator pompy cyrkulacyjnej Circulation pump 36 67 Internetowy sterownik kotta z kontrola temperatury spalin programmer e Programator Auto Lato Automatic summer programmer e Programator ogrzewania pod ogowego Floor heating programmer Tablica dobowa Daily schedule is used for all programmers Daily schedule is set with arrows on the keyboard After selecting the programmer use up and down arrow to select weekdays for which the temperature is reduced A weekday is displayed and the temperature can be reduced Time for which the value is changed is shown and the dash for a specific time blinks Temperature change accuracy is 30 min Use up and down button to change the value dash on the bottom is the lower temperature Press left and right arrow to change the time Programmer setting method is the same ffor all programmers Select Regulator temperatury kotta Boiler temperature regulator in Ustawienia
64. tomatically removes flue gases in the chamber it 33 67 Internetowy sterownik kotta z kontrola temperatury spalin Parameter Description is important for hopper type boilers Blow in time determines time to switch the blower ON Range Os to 90s gt Spi Bik Blow in Defines interval between subsequent blow ins P Range 1min to 15min interval Parameter relates to the range of temperature directly before reaching set temperature where the controller automatically reduces the blower power Strefa automatycznej Within this range with the increase in CH 3 regulacji Automatic temperature the blower reduces its speed to reach adjustment zone set temperature The blower speed is increased with the temperature decrease Depending on the requirements the range is adjusted by the user from 10 C to 0 C Range 0 C to 10 C 4 Moc dmuchawy w grzaniu Blower power in heating mode Range 25 to Blower power in heating mode 10096 moc dmuchawy w trybie Blower power set in manual mode Range 25 to 5 r cznym Blower power in 10096 manual mode 5 2 User parameters Select Parametry uzytkownika User parameters menu and press OK Paramelr a ck Liz tkowunika Press up or down arrow to select Parametry uzytkownika User parameters menu items Press OK to edit Press up and down arrow to change the value Press OK to confirm Press ESC to cancel and exit Item Parameter Descripti
65. trzny External alarm Op Znienie Delay Inwersja wejscia Output inversion Zatrzymanie sterownika Controller OFF for screw feeder only Added Auto Lato Automatic summer mode programmer Added Programator Podtog wki Floor heating mode programmer Pump activation at tempCO gt Temp MIN Floor heating pump stopped in LATO Summer mode Added Factory settings restored by pressing ESC at power supply on Added Room thermostat set temperature logging Added Floor heating thermostat set temperature logging Added Display information on website controller in LATO Summer mode important information in Auto Lato Automatic summer mode Added Feeder and blower OFF when switching to manual mode Added Fast switching between Manual Auto mode by pressing and holding ESC Added Readout averaging 64 logs table Added After feeding the fuel in HEATING mode and switching to sustain mode the blower will operate for min 60 seconds Added Analysis of boiler put out in sustain mode Wygaszenie kot a boiler put out alarm is generated when the flue gas temperature does not rise by 5 deg in sustain mode Added Alarm operation Damaged floor heating temperature sensor Added Parameter Niezalezna praca pompy mieszajacej Independent mixing pump operation If parameter is active mixing pump operates independently from the CH 8 67 Internetowy sterownik kotta z kontrol temperatury spalin U OS gt ZL NS E
66. udost pnianie sterownik w dla wybranych lub wszystkich u ytkownik w portalu apenas id y szyfrowane po czenie SSL kt re wykorzystuje 256 bitowy klucz AES kom rkowych kablowych itp brak sta ego adresu IP u ytkownicy internetu ADSL np Neostrada trudno ci w konfiguracji router w Y ocniwo KOT TAL Fig 23 Main eSterownik pl website screen 4 Main data Nazwa name any name identifying the controller Udost pnij sterownik publicznie Share controller share controller on eSterownik pl website with each visitor read only user may change 61 67 Internetowy sterownik kotta z kontrola temperatury spalin controller parameters W cz powiadamianie na email Email confirmations ON turns on e mail confirmations for alarms Email do powiadamiania Confirmation email the confirmations and administrator messages will be send to the email entered at sign in Synchronizacja czasu przez Internet Synchronize time via Internet if this option is selected time is automatically synchronized with the server clock 5 Enter the following data Identyfikator Identifier Unique controller identifier Adres IP serwera Server IP address Proxy server IP address Port serwera Server port Proxy server port 6 The following data can be set on controller website panel Enter website panel by entering controller IP address administrator login and password default admin admin Select
67. ury spalin e NS ROS OS 22 gt NS Amended Priorytet CWU DHW priority mode error if temp CO CH temp is lower than temp MIN min temp CH pump operated in cyclic mode and DHW pump OFF Amended histogram data generation error Amended error when entering values manually in the floating point fields on the website Version 0 1 17 11 Amended SD card operation Added intermittent CH pump operation in DHW priority mode CH pump operation idle time for internal temperature regulator Added cyclic floor heating pump operation in DHW priority mode Changed mixing pump may activate at CH temperature 1 deg higher than the return water temperature temp Powrotu Changed floor heating pump activation allowed if temp CO CH temperature exceeds Temp MIN by 2 deg Changed DHW pump pump activation allowed if temp CO CH temperature exceeds Temp MIN by 2 deg Changed Max temp podajnika max feeder temperature setting range 40 110 deg Added local web server file buffering Added feeder idle time histogram for group combustion via website Added parameter Wyprzedzenie dmuchawy w podtrzymaniu dla T OKA Blower lead in sustain mode for RAM FEEDER Parameter determines number of blower cycles in sustain mode Added parameter Podbicie temp CO przy aktywnym priorytecie CWU Increase in CH temperature in DHW priority mode CH temperature increase Added pa
68. ut signalling external events in the 19 e y boiler room depending on connected device e g External alarm hopper hatch open smoke detector active or increased carbon monoxide concentration X Am zewnetrzny Delay time after which the external alarm is 20 Czas op nienia External generated Range 0s to 600s alarm Delay time Alarm Z WHEITZMy Possibility to set a reverse logic for alarm input Range 21 Inwersja wejscia External TAK Yes NIE No alarm Input inversion Alarm zewnetrzny NSE gt The controller can be stopped switching from manual Zatrzymanie po alarmie 22 External alarm Stop after mode with feeder and blower OFF after external alarm p alarm is generated Range TAK Yes NIE No Z Restore all controller settings as service settings In Zap uetawien 4 Parametry uzytkownika User parameters menu 23 serwisowych Save service h settings the parameters can be restored Range TAK Yes NIE No 6 Alarms Before alarm is generated it is indicated with a red LED on the control panel Select alarm with up and down arrow 1 1 read the message diagnose and remove the fault and press OK to confirm In case of more than one alarm scroll using left and right arrow e First line shows number of alarms 45 67 Internetowy sterownik kotta z kontrol temperatury spalin U S We 2 gt generated second shows the alarm message Alarm 1 4 Teme CO g
69. uzytkownika User settings menu to access active programmer for CH temperature setting Select Regulator temperatury kot a Boiler temperature regulator in Ustawienia uzytkownika User settings menu to access active programmer for internal temperature setting 37 67 Internetowy sterownik kotta z kontrola temperatury spalin 4 m SS Ly WW gt gt DD ez a Programator CO CH programmer Set temperature is set by the user Reduced CH temperature is set with Temperatura CO obnizona Reduced CH temperature Poziomu ustawien Setting level in Parametry uzytkownika User parameters menu Reduced temperature is used with a correct setting in Tablica dobowa Daily schedule b Programator CWU DHW programmer The programmer sets temperature for domestic hot water Reduced DHW temperature is set with Temperatura CWU obnizona Reduced DHW temperature Poziomu ustawie Setting level in Parametry uzytkownika User parameters menu Reduced temperature is used with a correct setting in Tablica dobowa Daily schedule c Programator pogodowy Weather compensation programmer The programmer may be used to set the boiler temperature depending on outside temperature For Programator pogodowy Weather compensation programmer apart from Tablica dobowa Daily schedule it is possible to set weather regulator parameters in two points Temperatury CO dla 10 C CH temperature for 10 C and Temperatury CO dla 1
70. y Version 0 1 17 15 Added new power for Spalanie Grupowe Group Combustion 30 kW Added T Termostat Thermostat active and K reg pokojowy Room Thermostat active Version 0 1 17 14 Amended forced standby cycle activated after 5 minutes not immediately following the controller reset Added winter summer operation mode logging after new fuel charge The data are automatically send to eSterownik pl Added automatic entry on new fuel charge on eSterownik pl following feeder operation time reset via LCD or website Added P on the display indicating priorytet CWU DHW priority mode activated Version 0 1 17 13 Changed Simplified DHW priority mode CH floor heating pump is always OFF in DHW priority mode Added automatic fuel consumption calculation based on feeder operation time Added logging fuel quantity after feed operation time reset via LCD panel or website Version 0 1 17 12 Added parameter Rozpoczecie grzania w ttoku Heating start in ram feeder heating is activated with a blower or feeder blower ON Changed description from Retortowy auto Retort auto to Retortowy grupowe Retort group Changed Min temp CO min CH temperature setting range 35 60 deg Added CH pump activation with Wygaszenie kotta Boiler put out alarm active pump activated if CH temperature is over 60 deg 5 67 Internetowy sterownik kotta z kontrol temperat