Home
SMART System User Manual
Contents
1. From the Lockout Menu Sie To Assign a Lockout Action to a preset zu Oe E Press Menu Preset Menu displays ME BR Press Edit 3 times Press Lockout Use Up Down buttons to assign the lockout action the preset will activate None means that no lockout actions have been assigned i Press Menu to go back to Preset Menu in r1 10 lame PR1 10 in P LE fa OVERRIDE LOCKOUT ACTIONS From Preset Menu Press Menu Main Menu displays Press Lockouts Press override Press Status Press either buttons the right side to lock or unlock stations On for locked and Off for unlocked 00009 Press Menu to to Preset Menu Station 0 On Type LCD Off Status Off PIS 0000 g 30 SN LOCKOUTS EXAMPLE A ONE PRESET LOCK For the following example the SMART System will lock and unlock a 10 Button station in a single room scenario The System will be setup such that Preset 1 in Room 1 will lock this station To unlock an alternate preset on another st
2. SMART System STATIONS SETUP LCD nooo ge E From Preset Menu On the Master Station Press Menu Main Menu displays Press Stations Press Station 0 L Use Up Down arrows to select a Station In the station name LCD refers to a Slave LCD Station nooo 1010100 24 5 8 ER E PASS Select Room NIME Press Room Use Up Down buttons to assign a room to a station Station LCD Roomt BL delay nn Ed PIS Select Backlight uU Press BL MR A Use Up Down button to select between backlight constant on constant off or instant on delay M off d Test the Station qu Press V Station will flash LEDs Press any other button to resume normal functions faton 1 LCD o BL delay SUZ PNS Staton DCD BL delay n FANS Return to Preset Menu l je 11
3. Select an Output Function Press out Use Up Down butions to latch the output port for a given executed preset The RDI can respond to the following actions Blackout un Blackout Turn the timeclock operations on or off Execution of Presets1 13 Combine or UnCombine 1 8 POLARITY This determines whether or not the Remote Device Interface should keep an active high or active low on a selected port anno m Give the Polarity of the Port Press pol Press Up button for the RDI to pull up high to latch or signal action The display will show Pol high Press Down button for the RDI to pull down low to latch or signal action The display will show Pol low Return to Preset Screen Press Menu 19 STATIONS 1 2 4 1 EE ES OL Nas FI 2 VL uo SMART System IR REMOTE STATION IR STATION 1 IR Sensor Receives infrared signals from remote control 2 LED Indicator Indicates function execution has been received IR REMOTE CONTROL 1 Presets 1 12 Press a button to execute a preset in a room 2 Master Room Level Buttons Adjust levels up or down in all zones within a room 3 Off Button Pre
4. amp 99 z ANNS Press Lockout Use Up button to select lockout action 2 Use Up Down buttons to Lockout Z Station 0 Action none rrride rU mm Select the 10 Button Station 7 Press Station D0000 Z wo Jm Ja select station 0 Select Action OFF for the Lockout ction m Press Action H Press the Off selection to the right Press Menu to go to Preset Menu Lockout 1 now must be linked to preset 1 in room 1 for the 10 Button station to get locked To link Preset 1 Room1 to Lockout 1 Press Edit 3 times If not already selected select preset 1 in room 1 Press Room Use Down button to select room 1 Press Preset Use Down button to select preset 1 Select Lockout 1 P d Press Lockout Use Up Down buttons to select lockout action 1 lt 32 LOCKOUTS SMART System Lockout 2 now must be linked to the other presets to unlock the 10 Button station To FE 1
5. Bess nooo a 358 a IAPS Bess rU Use the Up Down buttons select an input or output port latch 1 12 bi Select a Room Press Room Use the Up Down buttons to select a room that RDI will activate or sense The same port can be used for multiple rooms Select an On Function On none Bess 200 8 8 8 274 aj 4 all Press the 4th button down on the left When this button is lit the user can designate functions to the RDI Press on Use Up Down buttons to select an action for the given room when the input port has been latched The RDI can e Blackout un Blackout e Turn the timeclock operations on or off execute e Presets1 13 e Combine or UnCombine 1 8 iw SMART System STATIONS Select an Off Function Press off Use Up Down buttons to select an action for the given room when the input port is open The RDI can Blackout un Blackout C Turn the timeclock operations on or off execute a a Presets1 13 Combine or UnCombine 1 8 s Me 8 8 8 SEKR EZ g q D Bes
6. 41 Blackout 41 PASSWORD Changing Password 42 CLEARING THE SYSTEM Clearing and Setup 43 STATION WIRING CGablmg A4 HARDWARE PIECES 45 Removal of faceplate 45 SMART System SMART System OVERVIEW MASTER STATION BUTTONS 1 1 Mapped Buttons Illuminating Buttons mapped to the display Any button press results in the execution of the feature mapped to the button N st Lo 2 Up Down Buttons Wa Allows user to control highlighted feature displayed E z by the Mapped Buttons Mapped buttons are ued to adjust levels set time or curse through character fieldsdepending on thier set function Character fields will go SPACE amp 5 O through 9 lt gt 9 A through Z a through z 4 n n n Ti Ju jn n n e 3 Menu Button Gives access between the preset menu page and a menu of 8 other selections ClearSys Stations DimPatch Combines Lockouts Timers Pass word and Config 4 Edit Button When in the Preset activation page this button will allow the user to toggle between the 3 sets of preset pages Within one of the Menu pages it will allow the user to cycle through pages of one of the other topics ClearSys Stations Dim Patc
7. vs Select a Patch Page to edit Press Patch Use Up Down buttons to select f patch page FIF 3 8 i JIMS 00000 aj 1 gt Wa Select Dimmer to configure Press Dim Use Up Down buttons to select patch page Brod p 3 9 FANS 8 UL t B Br a Dimmer to a Room Press Room Use Up Down buttons to assign dimmer to a room Ne seh Assign a Dimmer to Zone within the e mes exa E room Press Zone Use Up Down buttons to assign dimmer to a zone SMART System PATCH NON DIMMING For lights that are disigned to turn on and off without dimming the SMART System has a NonDim feature NonDim dimmers will turn on above 50 and off below 50 From the Patch Screen Press Edit Press Nondim Press Up button assign a nondim press Down button to dim H D0000 8 28 228 ANS n n n n n a 1 t Note Multiple Dimmers can be assigned to a zone within a room but multiple zones cannot be assigned to the same
8. Select XGlobal Preset Wa Press with X er Use Up Down buttons to select XGlobal preset To not replace a preset select none pe ce E m ze ai 27 M SMART System COMBINES PATCH CHANGING Each combine action has the ability to switch to a different patch This is most useful in head table scenarios where XGlobal substitutions and simple preset zone combining is not desired From the Combine Menu To Change Patches when combine action ha Press Edit twice Press On Patch Use Up Down buttons to select the patch page you will use in the combine Select none to not change patches when combine action is engaged PA To go to a patch page when a combine action is disengaged Press Off Patch Use Up Down buttons to select the patch to go back to after combining Select none to not change patch after combine action is disengaged nj n n 9 9939 EE PE 827 Se 3 3 FANS 5 Baye alii de 2 g Press Menu to go to Preset Menu 28 SN LOCKOUTS OVERVIEW The SMART System has 20 lockout actions to lock and unlock stations All lockout actions can
9. det 10006 10000 From Timer Menu To turn off specific events Select Event Press Event Use Up Down buttons to select event Pro Tm 01 01 m Ca 4 EE AR a nj njojn Set Room to 0 Press Room Use Down button to go to 0 Set Preset to Use Down button to go to 0 Event T Room 0 smtwt s Pro Tm 01 01 vi g Ss SMART System CONFIGURATION SETTINGS Combines Tear Sys Stations Dim Patch Edit Lockouts Timers Password Contig FINS Remote edit yes Password no Master room 1 ne m g d 0000 mi 218 3 remote edit yes Password no fone 1 Edit pagan REMOTE EDIT Allows the user to record live from a station other than the master This affects edit functions on Slider LCDs If remote edit is set to no the LCD will not display any Preset editing screens The re
10. jo NUIT TE setup Lockout 2 to the ue ae Select preset 2 in room 1 WAIN Press Preset Press Up button to select preset 1 Select Lockout 1 Press Lockout 10 10 ohhh PN Use Up Down buttons to select lockout action 2 PASS Repeat the same action for presets 3 through 13 OFF is 13 Now all presets except preset 1 will lock the station Remember once the station is locked out it is inoperable and must be unlocked by another station EXAMPLE A ONE PRESET LOCK For this example the SMART System will lock and unlock the same 10 Button station inasingle room The system will be setup such that presets located on the left hand side of the controls presets 1 2 3 7 8 9 and OFF will lock the 10 Button and presets on the right hand side presets 4 5 6 10 11 and 12 will unlock In this example the 10 Button station will be on address 0 TO SETUP From Preset Menu To Setup a Lockout Action to lock the 10 Button Tear Sys Stations Dim Patch Combines Press Menu Press Lockouts 33 SMART System LOCKOUTS
11. Use Up Down buttons to select room for the preset Select Preset Press Pr Use Up Down buttons to select preset Preset Press Edit Press Global Press Up button The display should change from Global no to Global yes Select Room Press Edit twice The display should show Global below Rm and Pr in the left hand part of the screen Press Edit again GLOBAL should display at the top Press Rm Use Up Down buttons to select room PRESETS Select Zone to be edited Press Zn Use Up Down buttons to select zone Adjust Level SMART System Zni Rmi Lv100 Pri Skip yes SU a nj nj n u HmT GLOBAL 10 10 WS Press Lv Use Up Down buttons to adjust level or use Full Off 10 increase by 10 or 10 decrement by 10 Unskip Zone Press Skip Press Down button Skip yes should change to Skip no A zone that is left on Skip yes will not be affected by this preset Set Fade Time Press Edit Select Tm Use Up Down buttons incre ment by seconds Min Min increment by minutes and 10 10 to increment by 10 second intervals Name Preset Press Edit U Select Name Use Up Down buttons to select character Character fields will go SPACE 8 amp D through 9 lt gt 9 A through Z athro
12. Button Used in saving levels to a preset Also this button is used for paging different channels See recording presets and changing zone pages on pages 15 and 16 3 Off Button Press to Execute Preset 13 Off 4 More Button Toggles between Presets 1 6 and 7 12 5 Master Fade Rate Button Toggles the M R display 9 from displaying master control use and the fade rate of an executed preset It will also toggle the use of the M R level controls 6 from adjusting all zones within a room to adjusting preset fade rates when recording 6 Master Fade Rate Control Press to raise or lower level in a room or adjust fade rate as desired See recording presets about fade rate changes on page 15 7 Channel Level Controls Press to raise or lower an individual channel level within a room 8 Channel Levels 10 segment LEDS show intesity values from 0 to 100 on each channel 9 M R Levels 10 segment LEDs shows master fader action and fade rates up to 5 minutes lt STATIONS SMART System To Record a Preset Adjust Channel Level Con trols to desired levels Press and hold Record button Press Preset to be stored in Release both buttons View Fade Rate Press M R button To Change Fade Rate of a Preset Mex View Fade Rate Press and hold Record button Use M R Control to raise or lower fade rate Release Record when fin ished editing This changes the fade rate of the active preset C
13. OFF in room 1 for the 10 Button station to get locked To link Preset 1 Room1 to Lockout 1 Press Edit 3 times mm mj NU FE 33 PASS If not already selected select preset 1 in room 1 Press Room Use Down button to select room 1 Press Preset Use Down button to select preset 1 Select Lockout 1 um mm Press Lockout an ab Use Up Down buttons to select lockout action 1 Du Ur Select Preset 2 Press Preset Use Up button to select preset 2 Select Lockout 1 Press Lockout Use Up Down buttons to select lockout action 1 mT Min Pr2 10 Name PR1 10 4 Min TAANS To do Presets 3 7 8 9 and OFF follow the last two steps Remember that OFF is preset 13 LOCKOUTS Win JN PASS Win JN SMART System Lockout 2 now must be linked to presets 4 5 6 10 11 and 12 in room 1 for the 10 Button station to get unlocked To link P
14. Select Lockout Action 1 This should be already selected if not Press Lockout Use Down button to select lockout action 1 N HINDI Soo EE 28 23 z fog FAAS Select the 10 Button Station Press Station Use Up Down buttons to select station 0 Select Action ON for the Lockout Action Press Action dies Press the On selection to the right Now Setup a Lockout Action to unlock the 10 Button Select Lockout Action 2 z S WSS s NINN Press Lockout Use Up button to select lockout action 2 Select the 10 Button Station Press Station Use Up Down buttons to Lockout 2 Station 0 Action none Ca m Edi 0 C select station 0 Select Action OFF for the Lockout Action Press Action V f N Press the Off selection to the right Press Menu to go to Preset Menu SMART System LOCKOUTS Lockout 1 now must be linked to presets 1 2 3 7 8 9 and
15. a STATIONS DOUD MZ DANS anim Bon A000 SUZ iT SMART System 10 BUTTON STATION 1 Presets 1 6 7 12 when More is activated Press a button to execute a preset in room 2 Master Room Level Buttons Adjust levels up or down in all zones within a room 3 More Button Switches between Presets 1 6 and 7 12 4 Off Button Press to Execute Preset 13 Off SETUP 10 BUTTON From Preset Menu On the Master Station Press Menu Main Menu displays Press Stations Press Station 0 Use Up Down arrows to select a Station In the station name 10Btn refers to a 10 Button Station Select Room Press Room Use Up Down buttons to assign a room to a station Test the Station Press Test Station will flash LEDs Press any other button to resume normal functions ech Return to Preset Menu Press Menu SMART System STATIONS 2 BUTTON STATION 1 1 Button Press button to execute an assigned preset S 2 see below 2 Off Button Press button to execute preset 13 Off SETUP 2 BUTTO
16. dimmer lt COMBINES 24 SMART System OVERVIEW Combines allow multiple rooms function as one This scenario is most useful in aditoriums or meeting rooms with adjoining areas The adjoining areas will either mimic or activate presets in reference to the main area OVERLAPPING COMBINE ACTIONS Acombine action can combine from two to eight rooms by a single combine activation switch If two combine actions are joined with an overlapping of rooms between them the SMART System will conveniently operate the area as if it were one large combine action ACTIVATION The combine actions can be activated either by a physical switch wired via the backside of the Master Station or through the use of a Remote Device Interface The Combine Actions are last action events and will take effect on the next preceeding execution of a preset within the combined rooms To learn more about the RDI turn to page 17 lt COMBINES COMBINE SETUP From Preset Menu To Setup A Combine Press Menu Main Menu displays SMART System Press Combines Select a Combine Press Come E Use Up Down buttons to select a Combine Select Rooms to Combine Press Room Use Up Down MC c one room to combine Press Attach Press Room CS Use Up Down buttons to select another room to combine Press Attach Select and attach another room as needed EXAMPLE To Combine Rooms 2 3 and 8 Select a Comb
17. effect the one or multiple stations One lockout function can lock one station and unlock another The lockout actions are activated by a preset The Master Station can override all station lockouts if needed SETUP LOCKOUT ACTIONS From Preset Menu To Setup a Lockout Action Press Menu Press Lockouts Select a Lockout Action a Press Lockout Use Up Down buttons to select a lockout action Select a Station Press Station Use Up Down buttons to select a station If you forgot your station s address press Menu twice then Stations and find your station in one of the 16 slots Select the Action for the Lockout Action Press Action Press one of the selections to the right Select On to lock Off to unlock or None to do nothing none is the default for all stations Press Menu to go to Preset Menu 29 SMART System Tear Sys Stations Dim Patch Combines a RE PASS Lockout T Station 0 Action none ug det x nj ajn u TS SMART System LOCKOUTS ASSIGN LOCKOUT ACTIONS
18. omx remote remote remote 44 HARDWARE PIECES OVERVIEW 8 Back Circuit Board Contains electronics for processing SMART functions Standoffs Front Circuit Board Provides the front end for controls Standoffs Subplate Plate used for mounting SMART Sys tem Use 6 screw to mount to electrical backbox Faceplate Rounded neural design easily matches any decor Mounting Tabs Used to secure faceplate to subplate Latches onto threaded mounting bolts Mounting Bolts Secured to faceplate Latches the faceplate on via the mounting tabs REMOVAL OF FACEPLATE Work around area between faceplace and subplate with a flathead screwdriver pulling forward This will work the mounting bolts from the mounting tabs Over time the tabs will wear out if done repeatedly If the tabes become loose simply squeeze them with needle nose pliers If the tabs become SMART System worn out or malfunctions please contact the factory or a nearby dealer for service 45 SMART System Attention SMART System owners For Service Please contact your local r
19. two room senerio if Preset 1 was activated in room 1 and zones 1 through 4 are at full for that preset then zones 1 through 4 in room 2 will go to full If the two rooms were identical they would both have the same look ombine 1 Within Combine Menu Designate Zone Combining uj Press How Press Up button for preset combing or press Down button for zone combining B DT SS 5 i AWN 8 ait Ae nooo Note The setting of the combine How is a global setting All combine actions will either be preset or zone COMBINES XGLOBALS One of the 13 XGlobal presets can replace 1 preset per combine action The Xglobal Preset will replace only presets that are within the combined rooms Since they are global presets they will affect all zones in every room unless they are skipped For more on XGlobals turn to page 8 From the Combine Menu BN ZE To replace a Presets with an XGlobal DE EI Preset cus SC Press Edit 5 Select Presets to be replaced j Press Replace Pr Use Up Down buttons to select EN M ZE S preset To not replace a preset ize o select none cl
20. 3 E iii c T 7 Nye ce select hour Note clock is in eg ME 24 hours 1 12PM is 13 24 Change the Minute Press Min u Use Up Down buttons Ne mE H select minute EC 3 Ca NC 4 Press Edit to go intoTimer Menu Press Menu to to Preset Menu TIMECLOCK Ga Hr smtwt s Sw 8 8 0 m Menu Ae x jn aj n u PASS i PN E y 5 os lol smtwtis s Nr y 5 os o mu Hr sMtwt s m Set the Time to Activate the Event MJ Press Tm Use Up Down buttons to change i PN E y os 09000 Hr sMtwtfs SUC 09000 SMART System SETUP EVENTS From Timer Menu Select an Event Press Event Use Up Down buttons to select an event to edit H
21. Electronics Diversified Inc Revision C April 2005 2005 Electronics Diversified Inc SMART System User Manual OVERVIEW Master Station buttons 2 Connections 3 Power Consumption 3 PRESETS Overview 4 4 eN AE S E 4 Global Presets 6 XGlobal Presets 8 STATIONS Overview 9 Slave Be RBE 9 TO BUTION sive 12 2 Button 13 Digital Slider 14 Remote Device Interface 18 IR Remote Station 20 PATCH Overview 22 Patch 22 Non Dimming 23 COMBINES Overview 24 24 Overlapping Combines 24 Combine Setup 25 How Preset vs Zone 26 SGlobale 27 Patch Page switching 28 LOCKOUTS Overview 29 Setup Lockout Actions 29 Assign Lockout Actions 30 Lockout Override 30 Example1 One preset lock 31 TABLE OF CONTENTS Example 2 Left side preset 33 lock right side preset unlock TIMECLOCK Overview 37 Setup Clock 37 Setup Events 38 Turn On Off Events 39 CONFIG SETTINGS Remote Edit 40 Password 40 Master Room Assignment 40 Activate Patch
22. HANGING ZONE PAGES Slider stations have programmable zonal paging allowing the user to edit all or some of the zones within a room reguardless of slider station configura tion and zones within a room The user can view 4 6 8 or 10 zones at a time based upon how many slider controls there are The user can advance or page to another group of zones within the room Thus ona 4 channel slider the user can view the following zones 1 through 4 on the first page 5 through 8 on the second page 9 through 12 on the third page and 13 through 16 on the fourth 15 Dii p 1 122 1 l 1 1 7 lie EI eee a g E l l 1 1 Gi SIS STATIONS El E HO 000 z 3 T ac ac J ood 328 SE 8 a Combine Password SMART System To Change Zone Page Press Record button and Down Zone button on the page to be viewed Ex First Page would be the first Down Zone button The lowest LED over the slider button will flash Note The LED for the first page will not flash SETUP SLIDER STA
23. N assword From Preset Menu On the Master Station d e Press Menu Main Menu Displays Press Stations Det Press Station 0 Use Up Down arrows to select a SE Station In the station name 2Btn refers to a 10 Button Station Select Room Press Room e Use Up Down buttons to assign a room to a station god gg ZI ER NM D 33 PASS m E E 0 8 3 E e Select On Preset Press On preset Use Up Down buttons to assign a preset on a button Test the Station Press Test Station will flash LEDs Press any other button to resume normal functions i lt Vi ogg 8 PER 823 9 E 5 FAR Return to Preset Menu Press Menu om 284 938 EE E A 1000 STATIONS 14 SMART System DIGITAL SLIDER STATION 1 Presets 1 6 7 12 when More is activated Press a button to execute a preset ina room 2 Record
24. Note All changes are being recorded while the user is editing PRESETS mT Full Prt 10 1 10 Lv 1009 EN ill j mT BA Pri 10 Tm 00 05 10 7 Global no ff A 533 Off RMT GLOBAL Zn1 Rmi 410 Lv100 Pr 10 Ca Skip yes EN Ed Activate Global Function for this SMART System GLOBAL PRESETS Normal presets allow levels to be adjusted within a room and that room only Global presets allow the userto adjust different zones in different rooms Users can inhibit or skip zones so that they will not be affected by the preset A global preset is most useful in cases where lights in distant rooms need to be turned on simultaneously or where a special preset is needed for system wide control From Preset Menu To create a global press Edit Select Room Press Rm
25. TION From Preset Menu On the Master Station Press Menu Main Menu displays Press Stations Press Station 0 Room1 Channels 1 Page i Station 1 Sidr Ab EADS a n o n n LE nooo ond 9 988 38s 333 a oM a 8 iTS Use Up Down arrows to select a Station In the station name Sldr refers to a Slider Station Select Room Pa Press Room Use Up Down buttons to assign a room to a station Set Channel Size of Slider Press Channels Use Up Down buttons to designate the maximum number of zones that can be displayed on that station Test the Station Press Test Station will flash LEDs Press any other button to resume normal functions Return to Preset Menu Press Menu D STATIONS REMOTE DEVICE INTERFACE OVERVIEW The Remote Device Interface RDI allows the SMART System to communicate with other devices through maintain or momentary switching Each port has a latched On function and unlatched Off function allowing the user to activate to separate fuctions on one switch Example Preset 1 for Port1 On function and Preset Off for port 1 Off function Th
26. ages 18 19 From Preset Screen Press Menu Main Menu displays Press Config Press Edit Press Room Use Up Down buttons to blackout unblackout room fo E L Press Blackout Press Up button to turn blackout on and Down to turn off 41 SMART System 20300 Master room 1 LActive patch 1 Remote edit yes Password no rU DO0OD EE 8 88g 383 e Room T Blackout off 0000 Nu E ai mT lackout on 2g 8 det e SMART System PASSWORDING SUZ TZ CHANGING PASSWORDS The SMART System uses password protection to prevent unwanted clearing and editing of the system The default password is four hits in the upper left button on the Master Station This password can be changed for increased protection Al
27. appen Press Room Use Up Down butions to select a room PA Select the Room Where the Event will Select a Preset the Event will Activate Press Preset Use Up Down buttons to select preset time byminutes or the Hr Hr to change by hours Note timer is in 24 hours 1 12PM is 13 24 Select the Days That the Event Will Happen Press 3rd button on the left smtwtfs Highlight the day by uppercasing the day through multiple hits of the 3rd button on the left Ex smTwtfs Tuesday is highlighted Press the illuminated button to LT sel ctthe day gt Repeat for multiple days 38 SN SMART System TIMECLOCK TURNING ON OFF EVENTS I From Preset Screen To Turn On and Off all Events Press Menu x Press Timers The Timer Menu comes up n n nj 34 3 EE PSS Press Edit Press TCO Time Clock e Overrride EN ZE e Press either Up button to 217 zat Ro turn off all the events or 29 Down button to turn them 2 on Press Edit to return to Timer Menu Note TCO can be changed through the RDI See page 18 for more details 3 about RDI functions EventT FFF Room 0 Hr Pro smtwtis EN Tm 01 01
28. ation within the same room will have to be activated to unlock this station In this example the 10 Button station will be on address 0 TO SETUP From Preset Menu To Setup a Lockout Action to lock the 10 Button Press Menu Press Lockouts Select Lockout Action 1 This should be already selected if not Press Lockout Use Down button to select lockout action 1 Select the 10 Button Station Press Station Use Up Down buttons to select station O Select Action ON for the Lockout Action Press Action Press the On selection to the right i SMART System a FINNS gt On E of Let None bel m i a jEdit Menu MI jd a Lockout T Station 0 Off Action none None Ca EN mm Edit Menu MK jd Lockout T On Station 1 of n Action Or None 1 mj EE jEdit Menu Mi 31 LOCKOUTS SMART System Now Setup a Lockout Action to unlock the 10 Button Select Lockout Action 2
29. cord button on the Slider Stations will not work also except in paging msa ON Freel Screen Press Menu Main Menu displays Press Config Press Remote Edit Press Up button for yes or Down button for no PASSWORD Password Protection can be set on the Master Station such that menus dealing Lockout Timer Password Configuration Settings Combines Dimmer Patches System Clearing are safeguarded with a password Presets still can be edited at the Master and other stations The default password is four hits on the top left button To edit the password see page 32 NOTE Do not end password with a 1 From Preset Screen Press Menu Main Menu displays ___ Press Config Press Password on Press Up button for yes or Down button for no MASTER ROOM ASSIGNMENT The Master Room can be assigned any room and does not take up an address CONFIGURATION SETTINGS From Preset Screen Press Menu Main Menu displays master room continued Press Config Press Master room Use Up Down buttons to select a room ACTIVATE PATCH Select one of the 9 patch tables available on the SMART System to be active For more on patching go to page 19 From Preset Screen Press Menu Main Menu displays Press Config Press Active Patch Use Up Down buttons to select a patch BLACKOUT The SMART System allows the user to blackout rooms manually if needed This feature can also be set by an RDI see p
30. epresenative or dealer For Factory Assistance Electronics Diversified Inc 1675 NW Cornelius Pass Road Hillsboro Oregon 97124 Voice 800 647 2690 or 503 645 5533 FAX 503 629 9877
31. er 7 PASS o gt L Tn n n n e 2 Up Down Buttons Allows user to control highlighted feature displayed by the Mapped Buttons Used to adjust levels or set time nm E 4 a n 3 Menu Button Returns to the preset menu page 4 Edit Button Prompts for the next page within the Preset edit pages SMART System STATIONS To Edit Presets Press Edit sl Select Preset Press Pr e Use Up Down buttons to select preset Select Zone to be edited m I Press Zn E Ne ae Use Up Down buttons to ER e select zone ui Adjust Level Press Lv Use Up Down buttons to adjust level or use Full Off 10 increase by 10 or 10 decrease by 10 n et Fade Time Press Edit Select Tm Use Up Down buttons to increment by seconds Min Min to increment H by minutes and 10 10 HW to increment by 10 second intervals Return to Preset Menu Press Menu
32. h Combines Lockouts Timers Password and Configurations SMART System OVERVIEW CONNECTORS 1 2 1 Combines PIN 1 8 Combine Inputs PIN 10 Ground 0000000000 2 DMX Output PIN 1 Ground PIN 2 Data PIN 3 Data 3 Power Serial Connection PIN 1 Ground PIN 2 Serial PIN 3 Serial PIN 4 9 to 24 VDC POWER CONSUMPTION Operating Voltage 9 24V For small 1 8 Stations systems 15VDC is sufficient Larger systems 9 16 Stations must use a 24VDC Power Supply Current 12VDC Master Station 110mA LCD Slave 50mA Station 2 10 IR Stations 60mA Slider Stations 100mA RDI 100mA Rating based upon 10 channel slider Lesser channel models will have a smaller maximum value PRESETS OF PR2 PR3 Edit PR2 PR3 Edi m wan o i AK iw OVERVIEW The SMART System has 117 pre
33. ine aae Combine room 2 Press Room Press Up button Press Attach Combine rooms 2 and 3 Press Up button Press Attach iTS Combine T How Preset rU LAttach LIN n n PIS dun Combine rooms 2 3 and 8 Press Up button 5 times Press Attach To exit and save press Menu 25 SMART System COMBINES HOW PRESET VS ZONE COMBINING The SMART System can combine rooms in following ways through preset activation or zone copying When rooms are combined through presets the activation of one preset in one room will cause the activation of the same preset number in other rooms Thus if Preset 1 was activated in room 1 in a two room senerio Preset 1 in Room 2 would activate When rooms are combined through zones zones levels of one room s preset will follow into other combined rooms Back to the
34. is is useful for turning on and off combines or a blackout switch for a room Momemtary switching can be used by setting the On and Off functions to the same setting Example Preset 1 for Port 1 On and Off functions and Preset Off for Port 2 A custom keypad for a master control panel swtichboard may use momentary switching on the RDI to activate fuctions throughout the SMART System 1 PIN 1 12 input port latches PIN 13 common for input port latches PIN 14 9 24VDC from LAN PIN 15 Ground from LAN 2 Input LEDs 1 12 lamp on when latch is closed by 1 H outside source 0000000000000 0000000000007 000000000000 1 A 3 PIN 1 12 output port latches S PIN 13 common for output port latches Power Serial 4 Output LEDs 1 12 lamp on when RDI has Connection closed the latch STATIONS 0 iT SMART System SEUP RDI FUNCTIONS From Preset Menu On the Master Station Press Menu Main Menu displays Press Stations Press Station 0 Use Up Down arrows to select a Station In the station name RDI refers to the Remote Device Inter face N Select a Port Press Port
35. l buttons on the faceplate are accessible to making a new four digit code For password enabling turn to page 32 From Preset Screen Press Menu Press Password Type in Old four digit d Deag E zz d GER ooo 5 password Type in New password Type in New password again After OK press Menu to return to Preset Menu NOTE DO NOT TURN THE SMART SYSTEM OFF DURING ANY PART OF PROGRAMMING IN THE PASSWORD If inaccurate information is placed in the SMART System it will return back to the Menu Screen SMART System CLEARING THE SYSTEM CLEARING AND SETUP From the Preset Menu i Ane Press Menu Press Clear Sys Enter 4 digit password using the 12 keys on the Master Station Default password is 4 hits on the top left button Nc AFTER THE LAST DIGIT IS PUT IN THERE IS NO RETURNING AND NO OUTSIDE COPY CAN BE MADE OF THE PROGRAM Good Bye will appear on the eee verifying erasure Good bye Select Room Size Use Up Down buttons to select the number of rooms Pre
36. om thus dsignated on the master station as X Because they are a global preset they will affect only those zones in rooms that are not skipped They can only be activated with a combine function and only be activated from stations within the combined room To assign an XGlobal Preset to a Combine function turn to page 25 From Preset Menu To create an XGlobal press Edit Select Room Press Rm Use Up button to select room X The display should show Global below Rm and Pr in the left hand part of the screen Press Edit Select Roomto Edit Press Edit again GLOBAL should display at the top Press Rm Use Up Down buttons to select room Follow the directions on page 7 for editing Global presets STATIONS OVERVIEW The SMART System can handle up to 16 stations 6 types of stations are available on the SMART System LCD Slave 10 Button 2 Button Digital Slider IR Remote and Remote Device Interface Stations can be spread out over 1000 feet of Alpha 1133 The SMART System can only address one station and cannot allow mirroring of stations The Master Station itself can be used as a station and is non addressable To read how to select the room the Master station will operate turn to page 31 SLAVE LCD STATION 1 Mapped Buttons Illuminating Buttons mapped to the display Any button press results in the execution of the feature mapped to the button D z
37. reset 4 Room to Lockout 2 Press Edit 3 times Select preset 4 in room 1 Press Preset Use Up button to select preset 4 Select Lockout 2 Press Lockout Use Up Down buttons to select lockout action 2 Select Preset 5 Press Preset Use Up button to select preset 5 Select Lockout 1 Press Lockout Use Up Down buttons to select lockout action 2 To do Presets 5 6 10 11 and 12 follow the last two steps 36 SN SMART System TIMECLOCK OVERVIEW The SMART System has 20 timeclock events Each event can be programmed to activate one preset in one room Events are setup on a weekly timer and individual events can be pro grammed from once a week to every day The operations of the time clock can be turned on and off as needed SETUP CLOCK From Preset Menu Sie Ze zii To Change Clock Time zu M eh Press Menu es ven m Press Timers Timer Menu displays Press Edit Change the Day 3 ENE eam ZE Ds Ke Use Up Down buttons to 22 SS trm select day fd Change the Hour Press Hour B TEMPS Use Up Down buttons to
38. sets total Each of the 8 rooms have 13 user editable presets plus 13 XGlobal Presets The user has access to 7 presets at one time from the Preset Menu To access the other six presets press the More button The 13th preset labeled OFF will be accessable in both screens EDITING LEVELS TIMES To Edit Presets Press Edit Select Room Press Rm Use Up Down buttons to select room Select Preset Press Pr Use Up Down buttons to select preset Select Zone to be edited Press Zn Use Up Down buttons to select zone Adjust Level Press Lv Use Up Down buttons to adjust level or use Full Off 10 increase by 10 or 10 decrease by 10 lt SMART System PRESETS Set Fade Time Press Edit Select Tm Use Up Down buttons to increment by seconds Min Min to increment by minutes and 10 10 to increment by 10 second intervals nooo nooo Name Preset Press Edit Select Name m Use Up Down butions to Ee A select character Character Im fields will go SPACE 8 9 95 8 V Othrough9 5 lt gt A through 7 1 athrough z Use 0 a and A to quickly jump to characters Ur GONE Return to Preset Menu Press Menu
39. ss Menu Number of rooms 1 Select maximum Zone size for eac room Press a room button Rm1 Rm2 etc Use Up Down buttons to set the maximum number of zones for that room The user can spread the 100 zone limit across the number of rooms selected Press Menu I E Rm4 Zni2 Rm8 7 12 im Zni2 Zni Rm2 2 12 Zni Rm3 2 12 Rm7 dit 43 SMART System STATION WIRING Standard cabling 3 cables DMX cable Belden 9842 1000 Power cable 2 18 AWG 1000 LAN cable Alpha 1133C 10007 dimmer am master remote remote remote Ge L power supply Option 1 2 cables both cables total 10007 DMX Power cable Belden 9843 pair 1 dmx pair 2 15 24 both wires pair 3 ground both wires LAN cable Alpha 1133C Power dimme ana dmx master remote remote remote lan Option 2 1 cable 500 w up to 8 stations 1000 w up to 4 stations DMX Power LAN cable Belden 9844 pair 1 dmx pair 2 lan pair 3 15 24 both wires pair 4 ground both wires lan power dimmer master ana
40. ss to Execute Preset 13 Off 4 LED Indicator Indicates function execution has been transmitted SMART System STATIONS SETUP IR REMOTE From Preset Menu On the Master Station a Press Menu Main Menu displays Press Stations Press Station 0 Use Up Down arrows to select a mit Station In the station name IR refers to a 10 Button Station e 0 Select Room Press Room Use Up Down butions to assign a room to a station Station T 10Btn Boom Return to Preset Menu Press Menu ARA SMART System PATCH OVERVIEW The SMART System Patch Panel allows 250 dimmers to be patched to a maximum of 100 channels or zones Nine individual patch pages can be stored and can be acti vated manually through the Config page see page 33 or through Combine Actions see page 26 I god SZ SS DS S E g 8 3 83 88 ARS PATCH SCREEN From the Preset Menu To edit the configuration of a dimmer frm Press Menu Main Menu displays jJ Press Dim Patch
41. ugh z Use 0 and A to quickly jump to characters Return to Preset Menu Press Menu DUDU Zni Rmi 100 Pri es b AS D0000 FmT GLOBAL Skip ft 10 10 PIS z TANS 8 1010100 QI Edi m zm Pri 10 Tm 00 05 10 tee mT Pri Name lone e an fo fa PRESETS m 00000 EE DD 38 33 DD id J 8 8 LEE mE 559 PASS 880 ER SPF E E i JIMS RMT GLOBAL Full Zni AmX 10 Wvo Pri 10 Lauer x Skip yes PIS noon noooo CH SE SMART System XGLOBAL PRESETS 13 XGlobal Presets can replace presets in combined rooms The presets are not associated with any ro