WIMO 6CP10 - ElectricalManuals.net

image

Contents

1. Local panel operations The local panel is being used to read measured values to set parameters and to configure unit functions Some parameters however can only be set by means of a PC connected to one of the local communication ports Further some parameters are factory set Navigating in menus All the menu functions are based on the main menu submenu structure 1 Use the arrow keys UP and DOWN to move up and down in the main menu 2 For moving to a submenu repeatedly push the RIGHT key until the required submenu is shown Correspondingly push the LEFT key to return to the main menu 3 Push the ENTER key to confirm the selected submenu Push the CANCEL key to cancel a selection 5 Pushing the UP or DOWN key in any position of a sub menu when it is not selected brings you directly one step up or down in the main menu gt The active main menu selection is indicated with black back ground color The possible navigating directions in the menu are shown in the upper left corner by means of black triangular symbols Vaasa Electronics Group Wi MO Fi 8 Wimotec 24h support phone 358 0 20 753 3264 WMEC P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration nn nw nw nn 8 nn nn nn nn nn enn nnn Figure 3 1 1 Principles of the menu structure and navigation in the menus 6 Push the INFO key to obtain additional information about any menu item 7 Push the CANCEL
2. Parameter Value Unit Description Recorded Time s Duration of the sag swell values Min1 Un Minimum voltage value during the sag swell in the input 1 Min2 Un Minimum voltage value during the sag swell in the input 2 Min3 Un Minimum voltage value during the sag swell in the input 3 Avel Un Average voltage value during the sag swell in the input 1 Ave2 Un Average voltage value during the sag swell in the input 2 Ave3 Un Average voltage value during the sag swell in the input 3 Max1 Un Maximum voltage value during the sag swell in the input 1 Max2 Un Maximum voltage value during the sag swell in the input 2 Max3 Un Maximum voltage value during the sag swell in the input 3 2 4 Control func tions 2 4 1 Loc al Remote selection In Local mode the output relay can be controlled via a local HMI but it cannot be controlled via a remote serial communication interface In Remote mode the output relay cannot be controlled via a local HMI but it can be controlled via a remote serial communication interface The selection of the Local Remote mode is done by using a local HMI or via one selectable digital input The digital input is normally used to change a whole station to a local or remote mode The selection of the L R digital input is done in the Objects menu of the VAMPSET software NOTE A password is not required for a remote co
3. Accessories Order Code Explanation Note WIMOTEMP P1100 Pt100 sensor Cable length 5m VPA3CG Profibus Interface Module VAMP Ltd VSE001 Fiber optic Interface Module VAMP Ltd VSE002 RS485 Interface Module VAMP Ltd VX003 3 Programming Cable VAMPSet VEA 3 CG 200serie Cable length 3m VX028 3 Cable for VPA 3 CG Cable length 3m VX032 3 Back panel programming cable Cable length 3m PS WIMO im WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 29 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 8 Reference information Manufacturer Service data Wimotec Ltd P O Box 810 FIN 65101 Vaasa Finland Visiting address Yritt j nkatu 15 Phone 358 0 20 753 3200 Fax 358 0 20 753 3205 URL http www wimotec com 24h support phone Tel 358 0 20 753 3264 Email support wimotec com WIMO 358 20 753 3264 m WIMO Hm 30 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description SS ee WIMO im WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 31 We reserve the right to changes without prior notice Wimotec Ltd Street address Yrittajankatu 15 Phone 358 20 753 3200 Post address Fax 358 20 753 3205 P O Box 810 FIN 65101 Vaasa Intemet www wimotec com Finland Email support wimotec com E nO im WM 6C P10 EN001
4. Type U SAG LOG Type of sag Phases Duration U SAG LOG Duration of sag s Minl U SAG LOG Minimum phasel of Un Min2 U SAG LOG Minimum phase2 of Un Min3 U SAG LOG Minimum phase3 of Un Avel U SAG LOG Mean phasel of Un Ave2 U SAG LOG Mean phase2 of Un Ave3 U SAG LOG Mean phase3 of Un Max1 U SAG LOG Maximum phase1 of Un Max2 U SAG LOG Maximum phase2 of Un Max3 U SAG LOG Maximum phase3 of Un U SWELL LOG Date of swell yyyy mm dd U SWELL LOG Time of swell hh mm ss ms Type U SWELL LOG Type of swell Phases Duration U SWELL LOG Duration of swell s Max1 U SWELL LOG Maximun phase1 of Un Max2 U SWELL LOG Maximun phase2 of Un Max3 U SWELL LOG Maximun phase3 of Un Avel U SWELL LOG Mean phasel of Un Ave2 U SWELL LOG Mean phase2 of Un Ave3 U SWELL LOG Mean phase3 of Un Min1 U SWELL LOG Minimum phase1 of Un Min2 U SWELL LOG Minimum phase2 of Un Min3 U SWELL LOG Minimum phases of Un Count U VOLT INTERRUPTS Voltage interrupts counter Prev U VOLT INTERRUPTS Previous interruption Total U VOLT INTERRUPTS Total duration of voltage interruptions days hours Prev U VOLT INTERRUPTS a of previous interruption s Status U VOLT INTERRUPTS Voltage status LOW NORMAL U1 U VOLT INT SETTING Current state of U1 U1 lt U VOLT INT SETTING Voltage interrupt limit Period U VOLT INT SETTING 8h day week month year Date U VOLT INT SETTING Year month day WIMO E 16 Wimotec 24h support phone
5. s manual with the code VMV ENOxx If the VAMPSET user s manual is not available please download it from our web site at www vamp fi Remote contol connection The unit communicates with higher level systems e g remote control systems via the serial port REMOTE on the rear panel of the unit Modbus RTU SPA bus IEC 60870 5 103 Profibus ModbusTCP or DNP 3 0 can be used as REMOTE communication protocols see details in the technical description Additional operation instructions for various bus types are to be found in their respective manual Vaasa Electronics Group Wi MO Fi 26 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 7 1 7 1 1 Commissioning configuration Factory settings When delivered from the factory WIMO 6CP10 has got either factory default settings or settings defined by the customer The configuration can be read from the workshop test reports or from the final test reports Configuration during commissioning The settings of the unit can be defined and checked during the commissioning in accordance with the instructions given in chapter 5 of this manual The order can be for example the following 1 The scaling of the rated values of the phase currents CONF CURRENT SCALING menu 2 The scaling of the rated values of the voltages CONF VOLTAGE SCALING menu The scaling is done i
6. 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 4 3 Value Menu Submenu Description Time U VOLT INT SETTING Hours minutes seconds Event U VOLT INT SETTING Enabled IL On U VOLT INT SETTING Interrupt on event L Off U VOLT INT SETTING Interrupt off event ATi TR MOHICS of IL1 6 2 if Dem So f SIM S Figure 4 2 1 Example of harmonics bar display Operation indic ators LED indicator Meaning Measure Remarks Power LED lit The auxiliary power has Normal operation state been switched on Alarm LED lit One or several signals of The LED is switched off the output relay matrix when the signal that have been assigned to caused output Al to output Al and the output activate e g the START has been activated by one signal is reset The of the signals resetting depends on the type of configuration connected or latched Resetting latched alarm indicator The alarm indicator can be given a latching function in the configuration There are several ways to reset latched alarm indicator e From the alarm list move back to the initial display by pushing the CANCEL key for approx 3 s Then reset the latched alarm indicator by pushing the ENTER key e Acknowledge each event in the alarm list one by one by pushing the ENTER key equivalent times Then in the initial display reset
7. 4 5 1 Pin assignments of communication ports The pin assignment of remote port is presented in the following table Figure 4 5 1 1 Figure 4 5 1 1 Pin numbering of the rear communication port REMOTE Port Pin Signal REMOTE X3 1 X3 2 TX remote X3 3 RX remote X3 4 X3 5 TX local X3 6 RX local X3 7 GND X3 8 X3 9 8V WIMO mE WM6CP10 EN001 Wimotec 24h support phone 358 0 20 753 3264 19 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description Figure 4 5 1 2 Pin numbering of the front communication port Port LOCAL Pin Signal Front 1 Front 2 RX RS232 in Front 3 TX RS232 out Front 4 12V out Front 5 GND Front 6 DSR in Front 7 Front 8 Front 9 NOTE DSR must be connected to 12V to activate the front panel interface 4 5 2 Protoc ols SPA bus WIMO 6CP10 has full support for the SPA bus protocol including the following features e event transfer e the transfer of status data e the transfer of measurement data e the reception of control commands e the reading and writing of setting values e the reading of multiple consecutive status data bits measurement values or setting values with one message The physical connection from a unit is by default 9 pin D connector with TTL level signals This can only be used to connect to an external bus connection device or to a modem Alternatively a TTL RS 232 conversion cable can be used with this ser
8. e Time zone for NTP TZone e NTP daylight saving time DST 5 6 Protocol menu Bus REMOTE PORT e The communication protocol of the REMOTE port Protoc e Message counter Msg e Communication error counter Errors e Communication time out counter Tout LOCAL PORT e Normally none e SPA bus e Extension port Teee E E AU eee WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration MODBUS The device slave number at Modbus Slave Protocol or the target slave number at Modbus Master Protocol Addr Modbus transfer rate bit s Modbus parity check Parity External I O bit s addresses SPA BUS SLAVE Slave number Addr when a unit is connected to SPA bus SPA bus transfer rate bit s IEC 60870 5 103 Slave address Addr Transfer rate bit s Measurement interval MeasIn Time synchronization response mode Sync IEC 60870 5 103 DISTURBANCE RECORDER ASDU23 activation ASDU23 samples per message smpls msg Time out DR Debug Fault Tag position Chn ChnPos PRO FBUS DP Profibus profile Mode The transfer rate of the converter bit s Profibus Tx Buf length InBuf Profibus Rx Buf length OutBuf Vaasa Electronics Group Wi MO Fi 24 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration DNP 3
9. 0 Transfer rate bit s Parity Slave address SlvAddr Master address MstrAddr Link layer confirmation timeout LLTout Link layer retry counter LLRetry Application layer confirmation timeout APLTout CNF Mode Double Bit input supply DBISup The IP address of the unit Ip Subnet mask N The IP address of the Gateway Gatew The IP address of the Name Server NameSv The IP address of the SNTP Server NTPSvr The port number used in remote protocol e g ModbusTCP communication Port Ta Ar ea Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 6 6 1 6 1 1 PC software PC user interface The PC user interface can be used for e On site parameterization of the unit e Loading unit software from a computer e Reading measured values to a computer Two RS 232 serial ports are available for connecting a local PC one on the front panel and one on the rear panel of the unit The serial ports are connected in parallel However if the connection cables are connected to both ports only the port on the front panel will be active To connect a PC to a serial port use a connection cable of type VX 003 3 You can also use the VAMPSET software through a TCP IP LAN connection Optional hardware is required Using VAMPSET program For more information about the VAMPSET software please refer to the user
10. Symbol Description 1 To Earth fault current Io 2 To Earth fault current Io 3 DII Digital input 1 4 DI2 Digital input 2 5 DI3 Digital input 3 6 PT100 RTD input PT 100 7 PT100 RTD input PT 100 8 12V 12V out 9 DGND Ground DGND 4 2 Analogue measurements e Phase currents l1 Irz and Irs terminals X1 1 6 e Earth fault current Io terminals X2B 1 2 e Phase voltages Uni Urz and Urs terminals X2A 3 5 4 3 Digital inputs Further the unit can collect status information and alarm signals via 3 digital inputs terminals X2B 3 5 The three digital inputs in WIMO use an internal 12 V dc auxiliary voltage of the unit terminal X2B 8 Potential free contacts must be available in the protected object for transferring status information to the unit 4 4 Output relay The terminal is equipped with one output relay e Output relay terminals X2A 7 9 m WIMO im 18 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 4 5 Senal communication connection e RS 232 serial communication connection for computers connector LOCAL RS 232 the connectors on the front and rear panel are connected in parallel e Remote control connection with the following options 1 TTL 9 pin 2 RS 485 9 pin 3 Plastic fibre 4 Glass fibre 5 Profibus RS 485 9 pin
11. Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 2 1 2 2 User interface General WIMO 6CP10 secondary substation measuring and monitoring unit can be controlled in three ways e Locally with the push buttons on the device front panel e Locally using a PC connected to the serial port on the front panel or on the rear panel of the device both cannot be used simultaneously e Via remote control over the remote control port on the unit rear panel WMO 6CP10 front panel The figure below shows the front panel of the unit and the location of the user interface elements used for local control WIMO6CP10 Measuring and Monitoring Unit a gt 3 Q ALARM 2 POWER CAE ppp a i lt D 44 DP a Wimom VYIOIA Figure 2 2 1 WIMO 6CP10 front panel LCD dot matrix display Keypad LED indicators RS 232 serial communication port for PC iS Vaasa Electronics Group Wi MO pa WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 2 2 1 Display WIMO 6CP10 is provided with a backlit LCD dot matrix display The display has 128 x 64 dots which enables showing 21 characters in one row and eight rows at the same time The display is divided into sections as shown in the next figure 2 3 5 av POWER i p Bk Wl E Bk war ak UA E a TI PF 1
12. is leading cos cosp PF PF Figure 2 3 2 2 Quadrants of power plane Vaasa Electronics Group Wi MO E3 Wimotec 24h support phone 4358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit Technical description WIMO 6CP10 Power Current Power cosfii Power factor quadrant related to direction voltage inductive Lags Forward capacitive Leads Forward inductive Leads Reverse capacitive Lags Reverse 2 3 3 Hammonics and Total Hamonic Distortion THD The device calculates the THDs as percentage of the base frequency for currents and voltages The device calculates the harmonics for phase currents and phase voltages from the 2nd to the 15th order The 17th harmonic component will also be shown partly in the value of the 15th harmonic component This is due to the nature of digital sampling 2 3 4 Voltage intenuptions WIMO 6CP10 includes a simple function to detect and measure voltage sags The function calculates the number of voltage interruptions and the total time of the voltage interruptions within a period The period is based on the real time clock of the device The available periods are e 8hours 00 00 08 00 08 00 16 00 16 00 24 00 e oneday 00 00 24 00 e one week Monday 00 00 Sunday 24 00 e one month the first day 00 00 the last day 24 00 e one year 15t January 00 00 31st December 24 00 After each per
13. key to revert to the normal display Vaasa Electronics Group Wi MO Es WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 9 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 3 2 Operating levels The unit has two operating levels User level and Configuration level The purpose of the configuration level is to prevent accidental change of unit configurations parameters or settings USER level Use Possible to read e g parameter values measurements and events Opening Level permanently open Closing Closing not possible CONHAGURATION level Use The configuration level is needed during the commissioning of the unit E g the scaling of the voltage and current transformers can be set Opening Default password 0002 Setting state Push ENTER Closing The level is automatically closed after 10 minutes idle time Giving the password 9999 can also close the level 3 2 1 Opening configuration level 1 Push the LEFT key and the RIGHT key on the front panel simultaneously ENTER PASSWORD KE F Figure 3 2 1 1 Opening the operating level 2 Enter the password needed for the desired level the password can contain four digits The digits are supplied one by one by first moving to the position of the digit using the RIGHT key and then setting the desired digit value using the UP key 3 Push the ENTER key Vaasa Electronics Group Wi MO Fi 10 Wimotec 24h support phone 4358 0 20
14. needed when connecting the Cabletroll 2000 to the WIMO 6CP10 NOTE Make sure that the cable shielding goes beneath the Cablletroll 2000 3 2 3 Other accessories WIMO 6CP10 has 3 digital inputs For example short circuit indicators can be connected to locate short circuit faults Other possible sensors or indicators are smoke sensors moisture sensors door switches fan alarms spray paint sensors etc Vaasa Electronics Group Wi MO E3 16 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 4 4 1 4 1 1 Terminal X1 Connections Rear panel view WIMO 6CP10 X2A LINA GAT 6 9 12 34 56 78 X2B g Figure 4 1 1 1 Connections on the rear panel of the WIMO 6CP10 Symbol Description IL1 Phase current L1 IL1 Phase current L1 IL2 Phase current L2 IL2 Phase current L2 IL3 Phase current L3 IL3 Phase current L3 E WIimo Ri WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 17 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description Terminal X2A No Symbol Description 1 Uaux Auxiliary voltage contact in parallel with one of phases L1 L3 2 PEN PEN 3 UL3 Phase voltage L3 4 UL2 Phase voltage L2 5 ULI Phase voltage L1 6 a 7 NO Relay normal open 8 COMMON Relay common 9 NC Relay normal close Terminal X2B No
15. or an internal Profibus module is required PS WIMO HC WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 21 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description IEC 60870 5 103 The IEC standard 60870 5 103 Companion standard for the informative interface of protection equipment provides standardized communication interface to a primary system master system The unbalanced transmission mode of the protocol is used and the unit functions as a secondary station slave in the communication Data is transferred to the primary system using data acquisition by polling principle The IEC functionality includes the following application functions e station initialization e general interrogation e clock synchronization and e command transmission It is not possible to transfer parameter data or disturbance recordings via the IEC 103 protocol interface DNP 3 0 WIMO 6CP10 supports communication using DNP 3 0 protocol The following DNP 3 0 data types are supported e binary input e binary input change e double bit input e binary output e analog input e counters Additional information can be obtained from the DNP 3 0 Device Profile Document DNP 3 0 communication is activated via menu selection RS 485 interface is often used but also RS 232 and fibre optic interfaces are possible m WIMO Hm 22 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid
16. signals are measured depend on the configuration Aa WIMO Cg WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 13 WIMO 6CP10 Measuring and monitoring unit Technical description Wimotec Lid Disturbance recorder parameters Parameter Value Unit Description Setting Mode Saturated Mode of the recording values Overflow Rate 32 Sample rate samples cycle 16 samples cycle 8 samples cycle 10ms 20ms 200ms 1s 5s 10s 15s 30s lmin Time s Recording time the maximum time calculated automatically PreTrig 0 100 Pre trigger time MnlTrig Trig Manual trig Size Size of one recording MAX time s The maximum time of recordings MAX size Maximum size of recordings Recorder Links Connected links links AddLink Add links ClrLnks Clear links Recorded Status Status of recorder values Time Status of pre triggering status ReadyRec The number of ready records m w No im 14 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 3 Applications The following example illustrate the versatile functions of WIMO 6CP10 3 1 Secondary substation measunng and monitoring WIMO6CP10 Monitoring amp Measurin ALARMS Figure 8 1 1 WIMO 6CP10 used in secondary substation monitoring WIM
17. the latched alarm indicator by pushing the ENTER key The latched alarm indicator can also be reset via a remote communication bus or via a digital input configured for that purpose E no mg WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 17 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 4 4 4 5 Reading event register The event register can be read from the Evnt submenu 1 Push the RIGHT key once 2 The EVENT LIST appears The display contains a list of all the events that have been configured to be included in the event register EVEHT LIST 14aT Code ESA Device restart 2806 89 86 12 25 12 514 i Figure 4 4 1Example of an event register 3 Scroll through the event list with the UP and DOWN keys 4 Exit the event list by pushing the LEFT key It is possible to set the order in which the events are sorted If the Order parameter is set to New Old then the first event in the EVENT LIST is the most recent event Adjusting display contrast The readability of the LCD varies with the brightness and the temperature of the environment The contrast of the display can be adjusted via the PC user interface Open VAMPSET software proceed to the DEVICE INFO menu and set desired contrast value to the display contrast block More about VAMPSET in chapter 6 on page 26 Vaasa Electronics Group Wi MO Fi 18 Wimotec 24h support phone 3
18. 0 08 300 0 s step 0 01 s or 0 02 s e Hyster hysteresis 0 2 10 0 step 0 1 e NoCmp no compare limit visible only for active lt mode Programmable stage link signals Alarm stages link signals Interval P Q S f P F cose tang Selectable Prms Qrms Srms 10ms 20ms IL1 IL3 IL IL max of IL1 IL3 or 100ms To Iocalc I1 I2 12 11 I2 In U12 U23 U31 Uline UL1 UL3 Uphase U1 U2 U2 U1 THDIL1 THDIL2 THDIL3 THDUa THDUb THDUc The outputs of the programmable stages can control output relay Al and alarm LED see Figure 2 2 1 and Figure 2 2 2 U P Q S f cosp THD Set limit value 14 Start Mode Select gt pd lt Set delay 0 08 300s i Delay ce a a i S a S A PEE basicalarmstage Figure 2 2 1 Principle of programmable stage m WIMO im 6 Wimotec 24h support phone 358 0 20 753 3264 WM6CP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description Latches alarmstages Figure 2 2 2 Programmable stages in the output matrix 2 3 Measurement functions 2 3 1 Fundamental frequency measurement All the measurements except frequency are based on fundamental frequency values They are not RMS values The device calculates the active P reactive Q apparent power S and energy measures E Eq E Eq from voltage and current measurements Phase currents Iu liz lis Measuring range
19. 08 NU le gy Beez 3 4 Figure 2 2 1 1 Sections of the LCD dot matrix display Main menu column Heading of active menu Possible navigating directions push buttons Measured adjustable quantity Measured set value Or Go Bo sa Vaasa Electronics Group Wi MO Fi 6 Wimotec 24h support phone 358 0 20 753 3264 WMEC P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 2 2 2 2 2 3 Keypad You can navigate in the menu and set the required parameter values using the keypad and the guidance given in the display The key pad is composed of four arrow keys one cancel key and one enter key a Rf CIA E lt vV gt IMO E Figure 2 2 2 1 Keys on the keypad Enter and confirmation key ENTER Cancel key CANCEL Up Down Increase Decrease arrow keys UP DOWN Keys for selecting submenus selecting a digit in a numerical value LEFT RIGHT NOTE The term which is used for the buttons in this manual is inside the brackets pe Gg bo a Indicators The unit is provided with two LED indicators ALARM POWER Figure 2 2 3 1 Operation indicators of the unit Power Auxiliary voltage switched on Alarm Programmable alarm indicator Vaasa Electronics Group Wi MO po WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 3 3 1
20. 3 3264 25 WM 6C P10 EN001 WIMO 6CP10 Measuring and monitoring unit Technical description 5 2 5 2 1 5 2 2 5 2 3 5 2 4 5 2 5 Tests and environmental conditions Disturbance tests Emission Conducted EN 55022B Emitted CISPR 11 0 15 30 MHz 30 1000 MHz Immunity Static discharge ESD Fast transients EFT Surge Conducted HF field Emitted HF field GSM test 1 MHz burst Voltage interruption EN 61000 4 2 class III 6 kV contact discharge 8 kV air discharge EN 61000 4 4 class III 2 kV 5 50 ns 5 kHz EN 61000 4 6 class III 1 kV 1 2 50 ws common mode 2 kV 1 2 50 us differential mode EN 61000 4 6 0 15 80 MHz 10 V m 80 AM 1 kHz EN61000 4 3 80 1000 MHz 10 V m 80 AM 1 kHz EN 61000 4 3 900 MHz 10 V m pulse modulated IEC 60255 22 1 1 kV differential mode 2 5 kV common mode IEC 60255 11 Test voltages Insulation test voltage IEC 60255 5 2 kV 50 Hz 1 min Surge voltage IEC 60255 5 5 kV 1 2 50 ps 0 5 J Mechanical tests Vibration IEC 60255 21 1 10 60 Hz amplitude 0 035 mm 60 150 Hz acceleration 0 5 g Sweep rate 1 octave min 20 periods in X Y and Z axis direction Shock IEC 60255 21 1 Half sine acceleration 5 g duration 11 ms 3 shocks in X Y and Z axis direction Environmental conditions Operating temper
21. 3264 19 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 5 1 Principle of parameter setting 1 Move to the setting state of the desired menu for example CONF CURRENT SCALING by pushing the ENTER key The Pick text appears in the upper left part of the display 2 Enter the password associated with the configuration level by pushing the LEFT and RIGHT keys simultaneously and then using the arrow keys and the ENTER key default value 0002 For more information about the operating levels please refer to 3 2 3 Scroll through the parameters using the UP and DOWN keys A parameter can be set if the background color of the line is black If the parameter cannot be set the parameter is framed 4 Select the desired parameter for example Inom with the ENTER key 5 Use the UP and DOWN keys to change a parameter value If the value contains more than one digit use the LEFT and RIGHT keys to shift from digit to digit and the UP and DOWN keys to change the digits 6 Push the ENTER key to accept a new value If you want to leave the parameter value unchanged exit the edit state by pushing the CANCEL key atar CURRENT SCALING cr pGURRENT SCALING a F DO Inom 16609 E gt AlrmjIsec OBJ Ionom 18888 Tosec 3 BA C Ioinr J HA 8 US 1 7 E C 3 CURRENT SCALING ET primary E ENTER Edit p h C CANCEL EK gt 1600 OJ 5 Figure 5 1 1 Changing parameters Vaasa Electronics Group
22. 4h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration Value Menu Submenu Description Diagram I IL2 WAVEFORM Waveform of IL2 Diagram I IL3 WAVEFORM Waveform of IL3 Diagram I IL1 TREND Trend of IL1 Diagram I IL2 TREND Trend of IL2 Diagram I IL3 TREND Trend of IL3 Uline U LINE VOLTAGES Average value for the three line voltages V U12 U LINE VOLTAGES Phase to phase voltage U12 V U23 U LINE VOLTAGES Phase to phase voltage U23 V U31 U LINE VOLTAGES Phase to phase voltage U31 V UL U PHASE VOLTAGES Average for the three phase voltages V ULI U PHASE VOLTAGES Phase to earth voltage UL1 V UL2 U PHASE VOLTAGES Phase to earth voltage UL2 V UL3 U PHASE VOLTAGES Phase to earth voltage UL3 V Diagram U ANGLE DIAGRAM 1 Diagram of line voltages Diagram U ANGLE DIAGRAM 2 Diagram of phase voltages Uo U SYMMETRIC Uo value VOLTAGES U1 U SYMMETRIC Positive sequence voltage VOLTAGES U2 U SYMMETRIC Negative sequence voltage VOLTAGES U2 U1 U SYMMETRIC Negative sequence voltage related VOLTAGES to positive sequence voltage THDU U HARM DISTORTION Total harmonic distortion of the mean value of voltages THDUa U HARM DISTORTION Total harmonic distortion of the voltage input a 26 THDUb U HARM DISTORTION Total har
23. 58 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration Configuration and parameter setting Operating level CONAG URATION e Choose and configure the digital inputs in the DI submenu e Configure the NO relay output in the DO submenu e Set the Device Setup the scaling for example Inom Isec etc and the date and time in the CONF submenu e Choose and configure the communication buses in the Bus submenu Some of the parameters can only be changed via the RS 232 serial port using the VAMPSET software Such parameters for example passwords are normally set only during commissioning Some of the parameters require the restarting of the unit This restarting is done automatically when necessary If a parameter is tried to change the unit will inform about the auto reset feature see Figure 5 1 REMOTE PORT Change will cause sutoboot Press CANCEL Bus 9606 8E1 F Figure 5 1 Example of auto reset display Press CANCEL to return to the setting view If a parameter must be changed press the ENTER key again The parameter can now be set When the parameter change is confirmed with the ENTER key a RESTART text appears to the top right corner of the display This means that auto resetting is pending If no key is pressed the auto reset will be executed within few seconds Se Oo hs WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753
24. 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 3 2 2 Password handling The passwords can only be changed using VAMPSET software connected to the local RS 232 port on the unit It is possible to restore the password s in case the password is lost or forgotten In order to restore the password s VAMPSET software is needed The serial port settings are 38400 bps 8 data bits no parity and one stop bit The bit rate is configurable via the front panel Command Description get pwd_break Get the break code Example 6569403 get serno Get the serial number of the unit Example 12345 Send both numbers to vampsupport vamp fi A device specific break code is sent back to you The break code will be valid for the next two weeks Command Description set pwd_break 4435876 Break the passwords The number 4435876 is sent by VAMP Ltd Now the passwords are restored to the default values See chapter 3 2 Re Oo hs WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 11 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 4 Operating measures Study carefully the operating instructions presented in chapters 1 to 3 in this manual before taking any operating measures or changing any unit settings or functions WIMO 6CP10 can be controlled via the unit front panel a PC running t
25. In 5A Phase voltages Uu U2 Us Measuring range 90 265 V ac Earth fault currents lo Measuring range lo 450 A Frequency f Measuring range 45 65 Hz 2 3 2 Power calc ulations The formulas used by the unit for power calculations are found in this chapter SO WIMO im WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 7 Measuring and monitoring unit Wimotec Lid Technical description WIMO 6CP10 Phase to neutral voltages measured Active power calculation for one phase Pa U 1 cosp Reactive power calculation for one phase Q U 1 sing where Un Measured L1 phase voltage Tha Measured L1 current 0 Angle between Uj and Ini Active reactive and apparent power are calculated as follows P P P P Q Qr O Q S JP 40 8 P COS o S 90 ra naa ind cap Reverse inductive power Forward capacitive power current is leading current is leading cosp cosp PF PF I cap Find Reverse capacitive power Forward inductive power current is lagging current is lagging cosp cos PF PF Figure 2 3 2 1 Quadrants of voltage current phasor plane Q 90 cap lt ind Reverse capacitive power Forward inductive power current is lagging current is lagging cosp cos p PF ERa Fi pr Reverse inductive power Forward capacitive power current is leading current
26. L1 DIAGRAM Diagram of active power PL1 Diagram P PL2 DIAGRAM Diagram of active power PL2 Diagram P PL3 DIAGRAM Diagram of active power PL3 Diagram P ACTIVE POWER Trend of active power TREND Diagram P REACTIVE POWER Trend of reactive power TREND Diagram P APPARENT POWER Trend of apparent power TREND E E ENERGY Exported energy MWh Eqt E ENERGY Exported reactive energy Mvar E E ENERGY Imported energy MWh Eq E ENERGY Imported reactive energy Mvar E nn E DECIMAL COUNT Decimals of exported energy Eq nn E DECIMAL COUNT Decimals of reactive energy E nn E DECIMAL COUNT Decimals of imported energy Ewrap E DECIMAL COUNT Energy control E E E PULSE SIZES Pulse size of exported energy kWh Eqt E E PULSE SIZES Pulse size of exported reactive energy kvar WIMO E WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 13 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration Value Menu Submenu Description E E E PULSE SIZES Pulse size of imported energy kWh Eq E E PULSE SIZES Pulse duration of imported reactive energy ms E E E PULSE DURATION Pulse duration of exported energy ms Eqt E E PULSE DURATION Pulse duration of exported reactive energy ms E E E PULSE DURATION Pulse duration of imported energy ms Eq E E PULSE DURATION
27. Measuring and monitoring unit WIMO 6CP10 Technical description 4 6 Connection examples 4 6 1 WIMO 6CP10 secondary substation measuring and monitoring unit PEN L1 L2 L3 COMM 1 RS232 COMM 2 RS232 VOLTAGE SUPPLY TOGSM Figure 4 6 1 1 Connection example of WIMO 6CP10 WIMO E WM 6C P10 EN001 i Wimotec 24h support phone 358 0 20 753 3264 23 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 5 Technical data 5 1 5 1 1 5 1 2 5 1 3 Connections Measuring circ uitry Rated current In Current measuring range Thermal withstand 5A 0 5 A 6 A continuously 25 A for 10 s 100 A for 1 s Burden lt 0 1 VA Rated current Ion 50 mA Current measuring range 0 100 mA Rated voltage Un 230 V ac Voltage measuring range 90 265 V ac Continuous voltage withstand 275 V ac Burden lt 0 5 VA Rated frequency fn 50 Hz Frequency measuring range 45 65 Hz Terminal block Solid or stranded wire Maximum wire dimension 2 5 mm 13 14 AWG Auxiliary voltage Type A standard Rated voltage Uaux 100 240 V ac 110 330 V de 110 120 220 240 V ac Power consumption Max permitted interruption time lt 10 W normal conditions lt 15 W output relay activated lt 15 ms 230 V ac Terminal block Phoenix MVSTBW or equivalent Maximum wire dimension 2 5 mm 13 14 AWG Digital inpu
28. O unit includes three phase voltage three phase current and earth fault measuring Unit measures also the temperature of the transformer WIMO 6CP10 is included with three digital inputs for various alarm stages as short circuit measurement or smoke detector 3 2 Accessones It is possible to connect various alarm indicators to WIMO 6CP10 s digital inputs m WIMO im WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 15 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 3 2 1 Temperature measurement Temperature measurement is possible by connecting a Pt100 sensor to the device The wiring resistance effect can be compensated by programming the resistance to the device In RTD menu the parameter Rcable is set equal to measured resistance of the wiring By using the WIMO TEMP Pt100 sensor there would not be any setting changes required The Pt100 sensor is connected to the terminals X2B 6 7 3 2 2 Earth fault alam Earth fault location in ungrounded networks is difficult By using a Cabletroll 2000 earth fault sensor in WIMO 6CP10 devices installed in the network makes it possible to locate the earth faults The Cabletroll 2000 is connected to terminals X2B 1 2 NOTE The terminal X2B 2 has to be grounded Cabletroll 2000 To WIMO 6CP10 Grounding of the cable shield Figure 8 2 1 Cabletroll 2000 attached to the cable of secondary substation No parameter setting is
29. Pulse duration of imported reactive energy ms E E Epulse TEST You may give test pulse Eqt E Epulse TEST You may give test pulse E E Epulse TEST You may give test pulse Eq E Epulse TEST You may give test pulse IL1 I PHASE CURRENTS Phase current IL1 A IL2 I PHASE CURRENTS Phase current IL2 A IL3 I PHASE CURRENTS Phase current IL3 A ILida I PHASE CURRENTS 15 min average for IL1 A IL2da I PHASE CURRENTS 15 min average for IL2 A IL3da I PHASE CURRENTS 15 min average for IL3 A Angle ANGLE DIAGRAM Angle of currents IL1 IL3 diagram To TV SYMMETRIC Primary value of zerosequence CURRENTS residual current Io A IoC I SYMMETRIC Calculated Io A CURRENTS I1 I SYMMETRIC Positive sequence current A CURRENTS I2 I SYMMETRIC Negative sequence current A CURRENTS I2 T1 TV SYMMETRIC Negative sequence current related CURRENTS to positive sequence current for unbalance protection THDIL I HARM DISTORTION Total harmonic distortion of the mean value of phase currents THDIL1 I HARM DISTORTION Total harmonic distortion of phase current IL1 THDIL2 I HARM DISTORTION Total harmonic distortion of phase current IL2 THDIL3 I HARM DISTORTION Total harmonic distortion of phase current IL3 Diagram I HARMONICS of IL1 o of phase current IL1 Diagram I HARMONICS of IL2 o of phase current IL2 Diagram I HARMONICS of IL3 aed of phase current IL3 Diagram I IL1 WAVEFORM Waveform of IL1 WIMO HU 14 Wimotec 2
30. Reading event reQGIStel ccscssseccssseessseeseseeeeseees 18 4 5 Adjusting display contra S ssssssssssssssrsesrreerrsserrrerrrrens 18 5 Configuration and parameter setting sssssssnsssssn555 5 19 5 1 Principle of parameter setting eect eee 20 5 2 Disturbance recorder menu DR ceesecsesteeeesseeeeeeeees 21 5 3 Configuring digital inputs DI eeeeseeeeseeeeeseeeees 22 5 4 Configuring digital OUtDUL ec eccceeeeteeesseeeeseeeeees 22 5 5 Configuration menu COMF ccsceeeseeeesseeeeseeesseeeees 22 5 0 Protocolmenu BUSAN AA 23 6 PC SOT LA 26 6 1 PC WSS INET a C esa ANAN AA 26 6 1 1 Using VAM PSET Pro Qra in wcisisssecarinscessnniecinescedionticins 26 6 2 Remote control CONNECTION cccceteeeesteeeeteeeeseeeeees 26 7 Commissioning configuration 27 AL Factory ANA AA 27 7 1 1 Configuration during COMMISSIONING 27 WIMO z WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 1 General This part of the manual describes the functions of the secondary substation measuring and monitoring unit WIMO 6CP10 and includes the unit operation instructions It also contains instructions for parameterization and configuration of the unit and instructions for changing settings The second part of the publication includes detailed protection function descriptions as well as applicati
31. WIMO 6CP10 Secondary substation measunng and monitoring unit Operation and configuration instruc tions Technical description WIMO E WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration Vaasa Electronics Group Wi MO Fi 2 Wimotec 24h support phone 358 0 20 753 3264 WMEC P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration Table of Contents L MS eal ssiscitssstsicecetecenasadicetusecedaansedsantuveiedendsrdecetawededsadeuvineaminde 4 L1 MME TS SNS cic cg a ener AA 4 1 2 Operating SATSLY asian aaa kaa 4 2 NEL INIEPIGCE GAAN 5 2d GEN Aka NAN AA 5 2 2 WIMO 6CP10 front panel manna nnnmanaaannnanananmananasananans 5 2 21 DIEDIAY dinsessndsienncrusienainssanetbiadnivelanisachpuitdaimlanusiubnsteinecoes 6 2 2 2 Keypa Haman AA ANG 7 2 2 3 VIG St ONS NGANGA AASA AA 7 3 Local panel operations 8 3 1 Navigating in MENUS cccsecssseesssseecssseecssseeeesseeesenees 8 3 2 Operating JEN Bina ANA 10 3 2 1 Opening configuration level 10 3 2 2 Password handling uuumuuusanaaaawananawanauaaaaaauunasanana 11 4 Operating MeaASUES ssssssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnna 12 4 1 Default displays ceeecscceesceeseeeseeeeeseeeseeeeseeesseeeesnees 12 4 2 Measured data serssnecincidascdi sch cenibeniedivbaicneieuedioenedaiads 12 4 3 Operation indicators sssessesssssseseerrserrerrrerrerersrieerrerrrern 17 4 4
32. Wi MO Fi 20 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration 5 2 Disturbance recorder menu DR Via the submenus of the disturbance recorder menu the following functions and features can be read and set DISTURBANCE RECO Recording mode Mode Sample rate Rate Recording time Time Count of ready records ReadyRe REC COUPLING Add a link to the recorder AddLink Clear all links ClrLnks Available links DO DI Uline Uphase IL U2 U1 U2 U1 I2 In 12 11 12 11 IoCale CosFii PF S Q P f UL3 UL2 UL1 U31 U23 U12 Io IL3 IL2 ILI Prms Qrms Srms Tanfii THDIL1 THDIL2 THDIL3 THDUa THDUb THDUc fy fz U12y U12z FT TS lasa WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration 5 3 5 4 5 5 Configuring digital inputs DI The following functions can be read and set via the submenus of the digital inputs menu e The status of digital inputs DIGITAL INPUTS 1 3 e Operation counters DI COUNTERS e Operation delay DELAYs for DigIn e Operation DI NO NC alarm display event mask on off event e The status of virtual inputs VIRTUAL INPUTS 1 4 Configuring digital output The following functions can be read and set via the submenus of the digital output menu e Th
33. ature 25 to 50 C Operating temperature display 0 to 50 C Transport and storage temperature 10 to 60 C Relative humidity lt 75 1 year average value lt 90 30 days per year no condensation permitted Casing Degree of protection IEC 60529 IP20 Dimensions W x H x D 96 x 96 x 151 mm Material Weight Colour code Polyphenylene oxide 1 2 kg m iO im 26 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Wimotec Lid Measuring and monitoring unit Technical description WIMO 6CP10 5 2 6 Package Dimensions W x H x D 105 x 105 x 175 mm Weight Unit and Package 1 4 kg a WIMO Hm Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 27 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 6 Construction 6 1 Dimensional drawing WIMO 6CP10 Multifunction Meter ome c aj E Figure 6 1 1 Dimensional drawing EEL WIMO mE 28 Wimotec 24h support phone 4358 0 20 753 3264 WM6CP10 ENO01 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 7 7 1 Order information When ordering please state Type designation WIMO 6CP10 Quantity Options see respective ordering code Ordering codes of MMO 6C P10 measuring and monitoring unit WIMO 6CP10 ORDERING CODE WIMO 6CP10
34. ctive power Reactive power Apparent power Active Energy exported imported Reactive Energy exported imported Power factor Phasor diagram view of voltages Phasor diagram view of currents 2nd to 15 harmonics and THD of currents 2nd to 15t harmonics and THD of voltages tel fo eg amp d e ag ine 8 2 o l a 3 On fz o 3 8 O Voltage interruptions Communication Voltage sags and swells IEC 60870 5 103 Modbus TCP Modbus RTU Profibus DP SPA bus communication Man Machine Communication display Man Machine Communication PC Number of phase current CT s Number of residual current CT s Number of voltage input VT s Hardware Number of digital inputs m w w m Number of alarm outputs E WIMO ia WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 5 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 2 2 Programmable stage WIMO 6CP10 has eight identical programmable stages PROGRAMMABLE STAGE 1 8 All programmable stages can be enabled or disabled one by one from the menu to fit the intended application All the enabled programmable stages have the following programmable parameters e Link link to a measured or calculated value see table below e Cmp mode lt or gt e Pick up alarm limit of the stage the setting range and the unit depend on the signal e t operation delay
35. e interuptionS amananwwanawaaanawanaawaanawaasana 9 2 3 5 Voltage sagsand swells la anannwwannawanawawana 11 2 4 COMMOITUNCHONS NANANA BAK INAAnANALA 12 2 4 1 Local Remote selection amaaaannawwananawaaanasana 12 2 5 Disturbance recorder 12 3 AppIICa TONS vccsicsssscassrssrsccensesvadesavsnvresnvswnceravevevesiestiavewainanianin 15 3 1 Secondary substation measuring and monitoring 15 3 2 ACCESS a NA aasa 15 3 2 1 Temperature measurement 16 3 22 Earth fault alai cactassecccesitincsanccepivstenteboneeeseoreachauics 16 3 2 3 Other ACCESSOMICS ccececcsseecsssecseseeessseesereeerees 16 A COMME CHONG La 17 4 1 RearpanelVvieW aaa AGANG 17 4 1 1 WIMO MOG PO papa assd 17 4 2 Analogue measurementSu uu mauuna nanana nawanaawaaasanananaan 18 4 3 Digita INPUTS pinic a AG 18 4 4 OUUDUETCIAY ccsisessvssdsunwsisssvvdvcsvesaiansessureanetesuessnniccdsnivesssn 18 4 5 Serial COMMUNICATION CONNECTION essees 19 4 5 1 Pin assignments of Communication ports 19 4 5 2 P0 18 84 9 eer ee rete ener eee ere teen eee eee 20 4 6 Connection example5S 1 mma nnnannnnananaanannaananananaans 23 4 6 1 WIMO 6CP10 secondary substation mea suring and monitoring UNIt oo cece eeeeeeseeeessseeessneeeeseneeessseeeeeeaees 23 5 Technical dala sississsississsssssssssscsvssasssssssssnssnvsssassssssssssasannceven 24 51 CONNECTION aa AA AGA 24 5 1 1 Measuring circuitry u s 24 5 1 2 A
36. e status of the output relay e The configuration of the output signal to the output relay The configuration of the operation indicator LED alarm Configuraton menu CONF The following functions and features can be read and set via the submenus of the configuration menu DEVICE SETUP e Transfer rate of local serial bus bit s e AccessLevel display Acc LANGUAGE e Language selection CURRENT SC ALING e Rated phase CT primary current Inom e Rated phase CT secondary current Isec e Rated Io CT primary current Ionom e Rated Io CT secondary current Iosec e The rated current of the Io current input Ioinp VOLIAGE SCALING e Rated VT primary voltage Uprim e Rated VT secondary voltage Usec e Voltage measuring mode Umode Vaasa Electronics Group Wi MO Fi 22 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Operation and configuration UNITS FOR MIMIC e Unit for voltage V kV e Unit for power kW MW FUNDAMENTAL RMS e Energy calculation mode e Display fundamental measurements e Display RMS measurements DEVICE INFO only display e Unit type e Serial number SerN e Software version PrgVer e Bootcode version BootVer DATE TIME SETUP e Date Dat e Time Time e Date information format Style CLOCK SYNC e Minute sync pulse DI SyncDI e Sync correction SyOS e RTC trim CkTrim e Synchronizing source SySrc internal
37. eal time Further the unit includes communication protocols for various communication situations Substation r 3 overhead line Distribution transformer 110kV network 20 kV overhead line 400 230V parad network Secondary substation 1 Secondary substation 2 a CIDE ERE A ER EEE RRS SSS ee KE a RB m Pr WIMO 6CP10 400 230V 400 230V Figure 1 1 1 Application of the monitoring unit Besides monitoring voltage current power etc in real time WIMO 6CP10 secondary substation measuring and monitoring unit can be used for monitoring and locating short circuits and earth faults Earth fault short circuit and many other special designed indicators can be attached into WIMO 6CP10 digital inputs Digital input alarms are also reported for user in real time The modern technology and a reliable construction ensures an extremely high availability for WIMO 6CP10 m WIMO im WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 3 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 1 2 Main features Fully digital signal handling with a powerful 16 bit microprocessor and high measuring accuracy on all the setting ranges due to an accurate 16 bit A D conversion technique Three universal digital inputs short circuit detection transformer condition monitoring smoke detec
38. eases over the swell limit U gt There are four registers for both sags and swells in the fault log Each register will have start time type which phases duration minimum average maximum voltage values of each sag and swell event Furthermore there are total number of sags and swells counters as well as total timers for sags and swells The voltage power quality functions are located under the submenu U Setting parameters of sags and swells monitoring Parameter Value Unit Default Description U gt 20 150 110 Setting value of swell limit U lt 10 120 90 Setting value of sag limit Delay 0 04 1 00 S 0 06 Delay for sag and swell detection SagOn On Off On Sag on event SagOff On Off On Sag off event SwelOn On Off On Swell on event SwelOf On Off On Swell off event Recorded values of sags and swells monitoring Parameter Value Unit Description Recorded Count Cumulative sag counter values Total Cumulative sag time counter Count Cumulative swell counter Total Cumulative swell time counter Sag swell logs 1 4 Date Date of the sag swell Time gt Time stamp of the sag swell Type Voltage inputs that had the sag swell w No ia WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 11 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description
39. he VAMPSET software a PC running suitable unit software or via a remote control system 4 1 Default displays WIMO 6CP10 has 5 default displays Display 1 5 contains IL1 IL2 IL3 and Io Display 2 5 contains U12 U23 U31 and Uo Display 3 5 contains UL1 UL2 UL3 and Uo Display 4 5 contains f P Q and S Display 5 5 contains PF and CosPhi You can change these default values VIA vampset software See the chapter 7 1 1 4 2 Measured data The measured values can be read from the P E I and U menus and their submenus Some of these values can also be seen in default displays 1 5 Value Menu Submenu Description P P POWER Active power kW Q P POWER Reactive power kvar S P POWER Apparent power kVA P POWER Active power angle P F P POWER Power factor f P POWER Frequency Hz Prms P RMS POWER RMS of active power Qrms P RMS POWER RMS of reactive power Srms P RMS POWER RMS of apparent power Diagram P PQ DIAGRAM Active and reactive power diagram Pda P POWER DEAMAND Active power demand value Qda P POWER DEAMAND Reactive power demand value Sda P POWER DEAMAND Apparent power demand value PFda P POWER DEAMAND Power factor demand value fda P POWER DEAMAND Frequency demand value Prmsda RMS POWER DEMAND Active power RMS demand value Qrmsda RMS POWER DEMAND Reactive power RMS demand value Vaasa Electronics Group Wi MO Fi 12 Wimotec 24h
40. ial port The unit can be equipped with a fibre optic option module which includes fibre optic connectors two plastic two glass one plastic and one glass IE a WIMO Hm 20 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description Modbus RTU WIMO 6CP10 is also available with Modbus RTU slave or Modbus RTU master These are often used in power plants or in industrial applications The protocols enable the transfer of the following data e events e statuses e measurements and e control commands The Modbus communication is activated via a menu selection The Modbus RTU protocols can be used with RS 232 RS 485 or the fibre optic interface ModbusTCP WIMO 6CP10 is also available with the ModbusTCP protocol This is often used in power plants or in industrial applications The protocol enables the transfer of the same data as with the Modbus RTU slave protocol The ModbusTCP communication is activated via a menu selection The use of ModbusTCP requires an external Ethernet module VEA 3CG Profibus WIMO 6CP10 is also available with Profibus Profibus DP slave protocol This is often used in power plants and in industrial applications The protocols enable the transfer of the following data e events e statuses e measurements and e control commands The Profibus communication is activated via a menu selection An external
41. iod the number of interruptions and the total interruption time are stored as previous values The interruption counter and the total time are cleared for a new period The pre previous values are overwritten The voltage interruption is based on the value of the positive sequence voltage U and a user given limit value Ui lt Whenever the measured U goes below the limit the interruption counter is increased and the total time starts cumulating Shortest recognized interruption time is 40 ms If the voltage off time is shorter it may be recognized depending on the depth of the voltage dip the ratio of the limit and the voltage value before the dip m WIMO Hm WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 9 WIMO 6CP10 Measuring and monitoring unit Technical description Wimotec Lid If the voltage has been significantly over the limit Ui lt and then there is a small and short under swing it will not be recognized Figure 2 3 4 1 t 50 60 t t 70 80 t 37 Time 90 ms Figure 2 3 4 1 Short voltage sag which is probably not recognized On the other hand if the limit Ui lt is high and the voltage has been near this limit and then there is a short but very deep dip it will be recognized Figure 2 3 4 2 A Us t 10 t 30 40 50 60 p Time 80 90 ms Figure 2 3 4 2 Short voltage sag that is recognized Setting parameters of the voltage sag measure
42. ment function Parameter Value Unit Default Description Ul lt 10 0 120 0 64 Setting value Period 8h Month Length of the observation Day period Week Month Date Date Time Time Measured and recorded values of voltage sag measurement function Parameter Value Unit Description Measured Voltage LOW Current voltage status value OK U1 Measured positive sequence voltage Recorded Count Number of voltage sags values during the current observation period Prev Number of voltage sags during the previous observation period m w No ia Wimotec 24h support phone 358 0 20 753 3264 10 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 2 3 5 Recorded Parameter Value Unit Description values Total s Total summed time of voltage sags during the current observation period Prev s Total summed time of voltage sags during the previous observation period Voltage sags and swells The power quality of electrical networks has become increasingly important The sophisticated loads e g computers etc require uninterruptible supply of clean electricity One of the most important power quality functions are sag monitoring and swell monitoring The voltage log is trigged if any voltage input either decreases under the sag limit U lt or incr
43. monic distortion of the voltage input b THDUc U HARM DISTORTION Total harmonic distortion of the voltage input c Diagram U HARMONICS of Ua Harmonics of voltage input Ua Diagram U HARMONICS of Ub Harmonics of voltage input Ub Diagram U HARMONICS of Uc Harmonics of voltage input Uc Enable U VOLTAGE SAG amp On off SWELL Status U VOLTAGE SAG amp Voltage status SWELL U lt U VOLTAGE SAG amp Alarm level SWELL U gt U VOLTAGE SAG amp Alarm level SWELL Delay U VOLTAGE SAG amp Delay in seconds s SWELL LVBlck U VOLTAGE SAG amp Block level SWELL SagOn U VOLTAGE SAG amp Sag on event SWELL WIMO E WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 15 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration Value Menu Submenu Description SagOff U VOLTAGE SAG amp Sag off event SWELL SwelOn U VOLTAGE SAG amp Swell on event SWELL SwelOf U VOLTAGE SAG amp Swell off event SWELL Status U SAG amp SWELL CNTRS High Count U SAG amp SWELL CNTRS Sag counter Total U SAG amp SWELL CNTRS Total sag length in seconds Count U SAG amp SWELL CNTRS Swell counter Total U SAG amp SWELL CNTRS Total swell length in seconds U SAG LOG Date of sag lyyyy mm dd U SAG LOG Time of sag hh mm ss ms
44. n the software block of the measured signals see Figure 7 1 1 1 Thus the scaling will affect all the measuring functions Display serialcom Figure 7 1 1 1 Principle for scaling the measured values of the unit 3 Configuration of communication parameters Bus menu See chapter 5 6 on page 23 4 Set measurements displays via VAMPSET and LOCAL PANEL CONF ee WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Operation and configuration MEASUREMENT DISPLAYS Lii Figure 7 1 1 2 Choose measurements to local panel display Vaara ecianies Greup WIMO E 28 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description Table of Contents L MOCHA aaa AA 3 Ll APPIICGTON sisarten eaaa e REKE NRS 3 1 2 Main featUureS sesssssssesrsserrsrrrreerresrrrrrrrnnsrrnnsrnnsrennenrnnsrent 4 2 PUNGUONS NGANGA 5 2 1 WIMO 6CP10 function dependencies 5 2 1 1 Unit function reference guide ececeeeseeecsteeeeeees 5 2 2 Programmable stage ee ceeeesecssseecsseeeessseeeesseeessseeeeeaes 6 2 3 Measurement FUNCTIONS ccececeeteeceeteeeseseeeseseeeesseeeeeees 7 2 3 1 Fundamental frequency mea surement 7 2 3 2 PowercalculationS aaannnaaannnaaasawanaannnasanassanan 7 2 3 3 Harmonicsand Total Harmonic Distortion THD 9 2 3 4 Voltag
45. ntrol operation 2 5 Disturbance recorder The disturbance recorder can be used to record all the measured signals that is currents voltages and the status information of digital inputs DI and digital output DO At the maximum there can be 5 recordings and the maximum selection of channels in one recording is 12 limited in waveform recording The digital inputs reserve one channel includes all the inputs Also the digital output reserves one channel en WIMO im 12 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description The recorder can be triggered by a digital input The trig signal is selected in the output matrix signal DR The recording can also be triggered manually When a recording is made also the time stamp will be memorized The recordings can be uploaded viewed and analysed with the VAMPSET program version 8 x or newer For more detailed information about for example uploading please see a separate VAMPSET manual Available links The following channels can be linked to a disturbance recorder e DO DI e Uline Uphase e IL e U2 U1 U2 U1 e 2 In I2 11 I2 I1 loCalc e CosFii PF S QP e f e UL3 UL2 ULI e U31 U23 U12 e Io e IL3 IL2 IL1 e Prms Qrms Srms e Tanfii e THDIL1 THDIL2 THDIL3 e THDUa THDUb THDUc e fy fz Ul2y U12z NOTE The available channels that is what
46. on examples accessories and technical data sheets 1 1 Unit features WIMO 6CP10 secondary substation measuring and monitoring unit is a compact multi function monitoring device with extensive measuring and calculation functions Setting and programming possibilities are comprehensive and versatile WIMO 6CP10 is ideal for secondary substation measuring and monitoring management The unit measures currents voltages and frequencies and calculates following values e Active reactive and apparent power e Active and reactive energy e Harmonics and THD of currents and voltages e Programmable average value calculations e One change over relay output Further the unit includes 3 configurable digital channels WIMO 6CP10 communicates with other systems using common protocols such as the Modbus RTU ModbusTCP Profibus DP IEC 60870 5 103 SPA bus DNP 3 0 1 2 Operating Safety The terminals on the rear panel of the unit may carry dangerous voltages even if the auxiliary voltage is switched off A live current transformer secondary circuit must not be opened Disconnecting a live circuit may cause dangerous voltages Any operational measures must be carried out according to national and local handling directives and instructions Carefully read through all operation instructions before any operational measures are carried out Vaasa Electronics Group Wi MO Fi 4 Wimotec 24h support phone 4358 0 20 753 3264 WMECP10 EN001
47. support phone 4358 0 20 753 3264 WMECP10 EN001 Wimotec Lid Measuring and monitoring unit Operation and configuration WIMO 6CP10 Value Menu Submenu Description Srmsda RMS POWER DEMAND Apparent power RMS demand value PLI P POWER PHASE 1 Active power of phase 1 kW PL2 P POWER PHASE 1 Active power of phase 2 kW PL3 P POWER PHASE 1 Active power of phase 3 kW QL1 P POWER PHASE 1 Reactive power of phase 1 kvar QL2 P POWER PHASE 1 Reactive power of phase 2 kvar QL3 P POWER PHASE 1 Reactive power of phase 3 kvar SL1 P POWER PHASE 2 Apparent power of phase 1 kVA SL2 P POWER PHASE 2 Apparent power of phase 2 kVA SL3 P POWER PHASE 2 Apparent power of phase 3 kVA PF_L1 P POWER PHASE 2 Power factor of phase 1 PF_L2 P POWER PHASE 2 Power factor of phase 2 PF L3 P POWER PHASE 2 Power factor of phase 3 Cos P COS amp TAN Cosine phi tan P COS amp TAN Tangent phi cosL1 P COS amp TAN Cosine phi of phase L1 cosL2 P COS amp TAN Cosine phi of phase L2 cosL3 P COS amp TAN Cosine phi of phase L3 Iseq P PHASE SEQUENCIES Actual current phase sequency OK Reverse Useq P PHASE SEQUENCIES Actual voltage phase sequency OK Reverse To P PHASE SEQUENCIES Io angle fAdop P PHASE SEQUENCIES Adopted frequency Hz PDir P PHASE SEQUENCIES Power direction Diagram P P
48. tion water detection transformer door indicator etc One relay output 5 special displays to show the main measurements Recording of events and fault values into an event register Latest events and indications are in non volatile memory Easy configuration parameterisation and reading of information via local HMI or with a VAMPSET user interface Built in self regulating dc dc converter for auxiliary power supply from any source within the range from 100 to 240 V ac or 130 330 V de Built in disturbance recorder for evaluating all the digital signals Wide range of measurement functions including overload conditions power outages under voltage and over voltage disturbance earth faults current unbalance reactive power energy and temperature Communications GPRS SPA OPC etc Leased modem line In case of earth fault WIMO 6CP10 registers the fault current which helps customer to locate the earth fault ee WIMO im Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 4 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 2 2 1 2 1 1 Functions WMO 6CP10 function dependencies Unit function reference guide Table of the unit dependent functions IEC symbol Measurement functions Function name Three phase current Neutral current Current unbalance Average and maximum demand current Phase and line voltages Voltage unbalance System frequency A
49. ts Intemal operating voltage Number of inputs 3 Internal operating voltage 12V de Current drain when active max Approx 5 mA Current drain average value lt 2 5mA Terminal block Phoenix MVSTBW or equivalent Maximum wire dimension 2 5 mm 13 14 AWG m WIMO im 24 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 5 1 4 Alam contact 5 1 5 5 1 6 Number of contacts 1 change over contact relay Rated voltage 48V ac Max make current N O 10 A N C 3 A Continuous carry 3A Breaking capacity ac N O 1250 VA N C 500 VA Contact material Terminal block Phoenix MVSTBW or equivalent Max wire dimension 2 5 mm 13 14 AWG Local serial communication port Number of ports 1 on front and 1 shared on rear panel Electrical connection RS 232 Data transfer rate 9600 38 400 kb s Remote control connection Number of ports 1 shared on rear panel Electrical connection RS 232 standard RS 485 with external module TTL Plastic fibre connection with external module Data transfer rate 9600 kb s Protocols Modbus RTU master Modbus RTU slave SPA bus slave TEC 60870 5 103 Profibus DP option TCP IP option DNP 3 0 a WIMO Hm Wimotec 24h support phone 358 0 20 75
50. uxiliary volta ge oe ececceccsseecssreecesteeesssaeeeseneeeees 24 5 L 3 Digital INPUTS peses 24 5 1 4 Alanm 9 Od ee eee 25 5 1 5 Local serial COMMUNICATION port 25 5 1 6 Remote control CONNECTION cecesteeesteeeeseeeeees 25 5 2 Tests and environmental conditions u s 26 5 2 1 Disturbance TOSS eceeecsstecssteecssseeessseeeseseeeees 26 5 2 2 ANON ES 26 WIMO WM 6C P10 EN001 Wimotec 24h support phone 358 0 20 753 3264 WIMO 6CP10 Measuring and monitoring unit Wimotec Lid Technical description 5 2 3 Mechanical e85 aasa 26 5 2 4 Environmental conditions 26 52 9 C AINO AA AA AA AA 26 GA a CRAG AA AA 27 6 CONN TON sini 28 6 1 DIMENSIONAL drawing cceceetteeeeeteeeseteeeeseeeesseeesseeeees 28 7 SPSL AAT ON Nas AA AA 29 7 1 Ordering codes of WIMO 6CP10 measunng and monitorning UIA saci asiaco anitacionsrnsccnnnsunsiccinanasaanavaaciaraneaneuntenansonnaopeane 29 8 Reference information ssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 30 WIMO HU 2 Wimotec 24h support phone 358 0 20 753 3264 WM 6C P10 EN001 Wimotec Lid Measuring and monitoring unit WIMO 6CP10 Technical description 1 11 Intoduc ton This part of the user manual provides a few application examples and contains technical data Application The numerical WIMO units include all the essential features needed to monitor secondary substations and to locate earth fault or short circuit in r