Home

General Specifications

image

Contents

1. General Model YHC4150X Specifications Portable HART Communicator The YHC4150X HART Communicator is the latest HART communicator from Yokogawa Corporation of America All HART field devices can be configured polled and trimmed using the YHC4150X with HART communications The YHC4150X is a full function HART Communicator supporting Universal Common Practice and Device Specific commands for commissioning configuration and maintenance operations Standard features include e 60 hours battery life w o backlight using AA alkaline batteries e Quick startup and connect 15 seconds Update new device profiles and firmware via the Internet YHC4150X is never out of your hands e Dongle coordinates AC power adapter and serial communication e Clone Upload Download configurations e Off line mode for developing reviewing configurations e Document and store more than 200 configurations e As found As left history with DMS software e 13 line 128 x 128 pixel graphic backlit display e Full alpha numeric keypad e Edit directly from Review Edit mode e Quick Menu access key SPECIFICATIONS SBT en non ey BASE UNIT 10 8 L x 4 1 4 to 2 YW x 1 to 1 e Dedicated text edit keys Fins oo e Programmable lock out settings 8 D ABS plastic case 1 7 lbs w batts e Contrast key for direct adjustment from any mode KEYPAD Membrane keypad 4 soft 8 single function e Elastic hand strap and adjustable shoulder
2. devices to commission replacements 5 C lt Ta lt 50 C YO KOG AWA amp Yokogawa Corporation of America GS YHC4150X 01 2 Dart Road Newnan GA 30265 Z Yokogawa Corporation of America 770 254 0400 Page 1 of 3 YHC4150X HART Communicator HART Communicator Includes CE Mark HART Lead Kit with 2500 YHC4150X adapter Batteries Communication AC Adapter Dongle RS 232 Serial Cable Universal Power Adapter Protective Boot Soft Carrying Case Adjustable Shoulder Strap User Manual CD Includes User s Manual and DPC Manager Utility oy Download Subscription Standard 3 year DOF Download Subscription Example Part Number YHC4150X 01 YHC4150X HART Accessories A900529 00014 HART Test Lead Kit Included w YHC Standard banana plugs mini grabbers 250 ohm resistor A36821 Std size 250 ohm shunt resistor Incl d w YHC req d for HART low resistance loops A900447 00052 DB 9 cable Male x Female 6 ft length incl d w YHC required for updates communication YHC Carrying Case incl d w YHC custom soft case with 4150 13 adjustable shoulder strap and HART lead compartment Adjustable detachable hanging strap incl d w YHC clips directly to A36937 l YHC attachment points Dongle incl d w YHC Communications and AC Adapter input to 4150 10A l mating YHC connector A36800 6 pack AA Alkaline Batteries incl d w YHC 6 required for operation 9B000007 Power Adapter 100 VAC to 240 VAC 50 60 Hz universal plug kit incl d
3. nitially assigned but user can enter his own after first log in Why subscribe 2 reasons 1 Products remain current With the release of HART 6 0 specifications new devices and new device revisions of older products will be released This subscription will enable you to download DOF s for new devices and new revisions for older devices Additionally the exclusive Field Device Revision Independence FDRI allows YHC4150X to automatically map configurations from older devices to newer devices by the same manufacturer in the event of field replacement This feature saves you valuable downtime and is exclusive to the YHC4150X HART product 2 Firmware updates Periodically enhancements improvements and or features are made available You may also decide to add new options when they become available The firmware is flashable i e field upgradeable so that the unit never has to leave the customer s facility for an update the result is no down time cULys Technical Considerations USL indicates investigation to the United States Standards UL 913 Sixth Edition CNL indicates investigation to Canadian National Standards Uni LAC CAN CSA C22 2 No 157 92 niversa Adapter oe Communication AC Adapter Dongle Dongle Adapter and AC Power Supply N Serial Cable to PC Each YHC has an electrical connector located at the top of the handheld The connector provides fast and secure connection to the Communication AC Adapter Dongle
4. strap 30 dual function 3 thumb keys e Thumb keys left hand for menu Up Down and Select DISPLAY 13 line 128 x 128 pixel graphic display e Custom use in place soft case with lead kit compartment 2 1 x 2 1 viewable area backlight FEATURES amp ADVANTAGES POWER Six AA alkaline or 100 240 Vac power adapter Use only approved alkaline batteries for YHC4150X supports all HART devices at the Universal and intrinsically Safe certified YHC4150X Common Practice command levels plus a large and growing list of devices at the Device Specific command level View our device TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C list at http fibu yokogawa usa com yhc4150 html Operating 23 F to 122 F 5 C to 50 C Use the YHC4150X to e Commission devices Step by step configuration Document as left configuration e Operations Reconfiguration for process changes Certification Intrinsically Safe ATEX cCULys Reconfiguration for batch runs a approved AA alkaline batteries only Document as found and as left configurations CONNECTIONS Standard banana jacks 4 center for HART Odu connector for dongle Dongle coordinates AC power and DB 9 serial communications Populate DMS database software Ex 4G e Device Maintenance EEx ia IIC T4 Troubleshoot devices with HART Intrinsically safe Exia View device error messages Class I Div 1 Groups A B C D T4 Clone
5. supplied with each handheld The Dongle is used to connect the AC adapter to the YHC when AC power is desired The Dongle is also used to connect the YHC to a PC for serial communications YO KOG AWA gt Yokogawa Corporation of America GS YHC4150X 01 2 Dart Road Newnan GA 30265 A Yokogawa Corporation of America 770 254 0400 Page 3of3
6. w YHC Paper Instructions for YHC4150X Paper and PDF On CD IM61AYHC1 E A instructions incl d w YHC YHC4150X HART Software Options DPCMAN CFG 15 15 Client yee Standard 3 year DOF Download Subscription Renewal DLS Subscript 1 DLS Subscript 5 DLS Subscript 10 10 14 units YO KOG AWA amp Yokogawa Corporation of America GS YHC4150X 01 2 Dart Road Newnan GA 30265 m Yokogawa Corporation of America 770 254 0400 Page 2of3 DOF Subscriptions for YPC 4150X Multi Function Tester with HART Communications HART communication support for the YHC4150X products and HART smart field devices takes two forms One is a Generic Device Object File DOF shipped with every YHC4150X unit The Generic DOF enables Universal and Common Practice HART commands to poll write and execute analog trim and loop test functions on any HART device Device Specific Commands are supported by device specific DOFs All device specific DOFs available at the time are included with each YHC4150X shipment New device specific HART DOFs are added at a rate of 5 to 8 per month and posted on our Download Site at http fibu yokogawa usa com yhc4150 html A Subscription to the Download Site provides the user with access to YHC4150X firmware updates and all posted DOFs for a period of 3 years after YHC4150X shipment Users will gain access to the Download Site by logging in with a User Name YHC serial number example 950680 S01 including hyphen and Password i

Download Pdf Manuals

image

Related Search

Related Contents

Daughtercard User Manual (PDF format)    User Manual - Turner Designs  Holmes HM729 User's Manual  la caméra. - Visual Impact France  Philips KEY019  2011-03-12 - CS5 - AMW 848 IT 4619-694  including repair parts and special tools list for  manual de instrucciones para una huelga general ciudadana  GENERAL DESCRIPTION  