1. 2 MEGAPIXEL NETWORK IR BULLET CAMERA NG BL321 QUICK GUIDE 1 6 How To Install 1 Make a hole of 25mm in diameter for passing cable 2 Drill four holes on the wall or ceiling and insert the anchors 3 Arrange the cables and fix the screws WALL ANCHOR 6x30 4EA 4 Attach the sunvisor and fix the sunvisor fixing bolt S sor O SUNVISOR Chapter 1 Install and Specification 1 1 Safety Cautions 1 This camera may be damaged by electrical and physical shock Use regulated 12V DC 1A power supply Do not throw or drop it onto floor 2 This camera can be used outdoor But ifi t is used outdoor it is required to use the sunvisor and avoid direct light from the sun Do not use it under water 3 In case it is installed at high location be sure to mount securely to prevent the unit from falling below 4 In case the unit fails DO NOT try to disassemble the product Contact or consult the distributor or an authorized technician for after sales service Warranty void for the product disassembled without an authorization from the distributor or an authorized technician 5 All responsibility by using this unit is on the user If the product is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment Sa 1 2 Package Camera Quick Guide Software amp User Manual CD 5 Loosen the bolt by using the 3mm wrench included
2. 6 Face the direction of the camera to monitor 7 Tighten the bolt to complete adjustment 1 7 Specification 1 7 1 Camera Specification Model No NG BL621 Type Megapixel network Day amp Night IR camera Image Sensor 1 2 8 SONY PROGRESSIVE SCAN EXMOR CMOS Effective Pixels 1984 H x 1225 V 1920x1080 1280x1024 Resolution 1280x960 1280x720 1024x768 640x480 320x240 Scanning System Progressive Scan LED OFF 0 01 Lux Min lllumination LED ON 0 Lux 60M Range Alarm Input Output Input 1 Output 1 IR LED 70PCS Lens Vari focal auto iris megapixel lens 1 3 Accessories for installation eee y ANCHOR 6x30 4EA gt SCREW 4x35 TP1 BIND SUS 4EA HEXAGON WRENCH 3 0mm L TYPE 1EA gt BOLT 1 4 20UNC L 6 1EA 1 4 Dimension 86 4 l 241 1 1 7 2 Camera Function ON OFF 6 Programmable Zones Day amp Night Auto Night Day WDR WDR 1 5 Back Light Front Light Auto 1 25 1 5 000 NTSO 1 12 5 1 8 000 PAL Suppress Rolling Manual Sense Up Auto 1 14 White Balance Auto Indoor Outdoor Fluorescent User Electronic Shutter 1 7 3 Network Specification OS Embedded Linux Network Interface RJ45 10 100BaseT Ethernet By web browser Leased Line Cable Modem Support Dynamic IP and Static IP ADSL usable under Router TCP IP UDP I
3. P RTP RTSP RTCP NTP HTTP DHCP FTP SMTP DNS DDNS Security User authentication PC OS WINDOWS XP WINDOWS VISTA WINDOWS 7 Web Browser IE 7 0 or higher H 264 MPEG 4 MJPEG 1920x1080 1280x1024 Image Network Support Summary Supported Protocol Resolution 1280x960 1280x720 1024x768 640x480 320x240 Compression Rate 200 1 Typical Frame Rate Max 30fps 1920x1080 Bit Rate 64 9000kbps Simultaneous Access Max 10 users Video Recording Recording in client PC with CMS or FTP Server Motion Detection Support Function OSD Support Alarm Input Output Support Dynamic IP Support IP Router Support DDNS Support 1 5 Camera setup Control board Focus Zoom adjustment direction 1 Unfasten the screw of the bottom door 2 Adjust the Focus and Zoom trimmers 3 Tighten the screw of the bottom door FOCUS 2 ZOOM Use a type driver for adjusting focus and zoom In case of operation Focus Zoom don t put stress excessively EXT VIDEO Extra video output terminal for installation Plug your test monitor in hear The cable is option POWER Light would turn on when power is on Rx Ix Light would turn on when the user connect by the network LINK Light would turn on when the LAN cable is connected to the unit SYSTEM RESET Press the button to reset when the unit is not working normally 8 FACTORY RESET Turn on the power and wait 2 minutes Press the b
4. e to install the following ActiveX control viewcam fn Information Bar Help Windows Internet Explorer To display the webpage again Internet Explorer needs to i resend the information you ve previously submitted If you were making a purchase you should click Cancel to avoid a duplicate transaction Otherwise dick Retry to display the webpage again Carcel Internet Explorer Security Warning 4 x Do you want to install this software a Name viewcam Publisher samhyunelectronics _ More options Instal D While files from the Internet can be useful this file type can potentially harm N your computer Only install software from publishers you trust What s the risk 12
5. following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server 168 Alternate DNS server Advanced ii OK j Cancel 2 2 2 Connect the camera with web browser Run web browser and input the default IP address 192 168 1 30 in URL line and press Enter Then below picture is to be shown 2 Web Manager for Camera Windows Internet Explorer g J e 192 168 1 30 Web Manager for Camera Megapixel Network camera For your safety and comfort Password Viewer G Manager B Y If the page does not open Please refer to Chapter 11 appendix in the CD 11 2 2 3 Input ID Password Shown the main page input ID and Password and click on Viewer to see the video feed Default administrator s ID amp Pas sword is admin lt Caution gt Please change default value of ID Password into new ones after the installation Reference Please refer to 5 3 Administrator s ID and Password Change regarding Change Administrator 2 2 4 Active X auto installation Click ins tall on the security certificate to load the Active X control If you choose Don t install the web viewer would not work This website wants to install the following add on viewcam from samhyunelectronics If you trust the website and the add on and want to install it click here GSES Net Viewer S What s the Risk Click her
6. on and Video Check 2 1 Installation On the assumption that User PC and the camera are used under static IP and the camera is to be directly connected with User PC or Local Network The installation procedure is to be 1 Connect the camera and PC with LAN Cable 2 Power on camera X Use regulated 12V DC 1A X Use PoE Power Over Ethernet The cable includes data and power so it s easy to install the camera So you can save time to install and cost When you connect the camera with PoE and DC adaptor Only PoE is used 3 Wait about 2 minute after power on camera the system will be booted 2 2 Network Setting and Video Check Default network setting value of the unit is to be IP Address 192 168 1 30 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 To connect the unitin user s PC change the setting value of PC network environment lt Caution gt Before changing the setting value please memorize the previous setting value on your PC 10 MEMO 2 2 1 Change the setting value of PC network environment Set IP Address Subnet Mask and Gate way of user s PC with 192 168 1 50 255 255 255 0 192 168 1 1 as shown on below picture internet Protocol TCPAP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the
7. tivate it Reference In case to reset hardware and network setting ID and password of user and Administrator will be automatically returned to the above defaultvalue Frame rate can be affected by the external video output option So factory defaultis off When you ins tall the camera enable this option Then disable itafter the installation 2 2 5 Complete the installation Upon installation Web Viewer appears and image of camera is to be seen Q Megapixel Metwork camera For your safety and comfort IH 264 calmezon Osa lel KAOLE Disconnect Save Capture OOOO O Path Selectstream codec and resoluton menu related to Stream selection live view was defined only by the admin H 264 MPEG MJPEG Default size is 640X480 Adjust the screen to the optimal size Recommendation Select the same size with stream resolution 2Window size Connection Disconnection Connect or disconnectto the stream Recording Saves the stream as a moving picture file in the avi format Capture Saves the snapshot as an image file in the bmp format S aving path Specify the file saving path Camera name Dis play camera title 8 Date Dis play the date Time Dis play current time Display the site information such as Day Night Motion Status Icon Alarm input output Display the stream information such as Audio and recording condition Stream Info 13 Chapter 2 Installati
8. utton for 3 seconds to set the ID and Passwords for administration and IP setting values to the Factory default Reference Please refer to Video Check in Chapter 2 and Chapter 5 System Setting regarding default value Refer to the manual in the CD A 1 7 4 Electric Specification Classification Specification Power Supply Regulated 12V DC PoE Power over Ethernet IEEE802 3af Current Consumption Max 1A DC 12V IR LED ON Operation Temp 45 50 Preservation Temp 20 60 Dimension 86 4 W x 101 9 H x 131 3 D mm Weight Approx 1kg 1 7 5 Alarm Input Output Alarm in GND Alarm out DC 12V 100mA out 1 7 6 Audio Input Output MIC Red I z e LINE OUT Black 1 7 5 Basic Setting Table Default Basic setting Remarks Network Static IP Dyna mic IP Static IP IP Server Enable Enable IP Address 192 168 1 30 Gateway 192 168 1 1 SubnetMask 255 255 255 0 Web Connection Port 80 RTSP Port 554 RTP Port Range 5000 5999 ID and Password Adminis trator ID Pass word admin admin User ID Password root root guest guest Domain of Related Server iplinker net Stream setting Stream 3 rts p lt ip address gt 554 stream3 DDNS Server Video out After installation deac