Home

H330 Module AT Command User Manual - Premier

image

Contents

1. V1 1 2 2012 11 24 Delete GTEINT command update mci mcell command V1 1 3 2012 12 13 Add chapter 16 PCM Command V1 1 4 2013 01 04 Update the name of this document V1 1 5 2013 01 10 Add XREG V1 1 6 2013 01 23 Update CMUX command V1 1 7 2013 03 06 Change the default value of cbaud and ipr to 0 H330 Module AT Command User Manual Page 2 of 304 Bs FIBOCOM H330 Module AT Command User Manual V1 1 8 2013 04 25 Update GTSET command descriptions V1 1 9 2013 05 10 Delete PS PN PU PP PC in section 8 1 5 V1 2 0 2013 05 22 Update MATONE and MTSM Change the default value of CBAUD and IPR V1 2 1 2013 06 18 Add Section 9 1 8 CUBAND command Update XREG command Page 3 of 304 Bs FIBOCOM Contents Ds SPY AC E EEEE E EE EAE A ETE AA EET EA 12 1 1 DUETA IISTO 0c 12 1 2 Target AUCICNCE seesssscsssscsseecssecssseecssecssseesssecsseessscsuecesseecsuecssseecssecssseessseesusessuscssueecsseessueccaseecssecssseessseesuseessees 12 2 Introduction to AT COMMANAS esseesssssecssescsseecsseecsseccsseccsseccsseccssecsssccssscesuseesuscesueeesseecsueccsseessseessseesssecsuscesueeesueeesseessneessee 13 2 1 AT Commands OVErViICW ssssssescsssscsseccsseccsseccssecsssecsssecssseessscesusccsusccsuecesseecsuecssseessseessseesssecsusessueeesuecesseessneessee 13 2 2 General System Abbreviations sssssssscsssscssescsseccsseecsseccsseccssecssseccssecsuseesssecsueessueecsuecesseecsnecessesssneesa
2. Command Syntax Response Action Remarks Set AT MIPOPEN lt Socket_ID gt OK The Set command lt Source_Port gt lt Remote_IP af returns lt Remote IP gt gt lt Remote_Port gt lt Protocol and lt Remote Port gt gt MIPOPEN parameters only for lt Socket_ID gt lt State gt lt Remot sockets opened in e_IP gt lt RemotePort gt Listen mode or MIPSTAT lt Socket_ID gt lt Status gt or ERROR lt err gt Read AT MIPOPEN MIPOPEN lt Socket_ID gt The Read command for each socket that can be opened OK or MIPOPEN 0 OK if there are no free sockets returns the numbers of the sockets that can be opened H330 Module AT Command User Manual Page 247 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT MIPOPEN MIPOPEN list of supported lt socket_ID gt s list of supported lt source_port gt s list of supported lt Destination_IP gt s list of lt destination_port gt s list of supported lt protocol gt s OK Example AT MIPOPEN MIPOPEN 1 2 3 4 A l sockets closed OK AT MIPOPEN MIPOPEN 1 3 4 Socket 2 opened OK The following table shows the MIPOPEN parameters lt Parameter gt Description Socket_ID A unique number that identifies a connection Valid socket numbers 1 2 3 and 4 Source_Port Port of source site Port range 1 65535 decimal digits Remote_IP IP IP of the remote site in th
3. SM detach SM activation error SM deactivation SS network error cause SS network reject cause SS network GSM cause lt cause gt contains a digit representing the error cause sent by network or internally lt description gt Is a verbose string containing the textual representation of the Cause H330 Module AT Command User Manual Page 42 of 304 Bs FIBOCOM 5 Call Control 5 1 Managing a CSD Data Call The H330 working modes can be divided into two modes of operation Data Mode In this mode once the H330 has established a link with the remote modem it does not respond to any data passing through it except for the Escape Sequence search The H330 becomes a transparent link connecting the terminal with the remote side Command Mode In this mode the H330 responds to the AT commands issued by the terminal This is the default working mode Note It is possible to switch between the operating modes The operating modes can operate simultaneously using the Mux and using multi channels operation 5 1 1 Simple Dialing In order to instruct the modem to dial a remote modem from an ordinary tone dialing telephone line enter the Dial command followed by the phone number For example type the following command ATD 876 5555 lt Enter gt Note If you receive characters which were sent you can disable this with using the Echo command ATEO lt Enter gt
4. Note The platform we use supports more than 14 baudrates those has been listed above but the high speed baudrate is hard to test we can not make sure it can be support or not so we list the baudrates we tested here but leave all support baudrates in test command return string Example AT IPR 7 OK AT IPR IPR 19200 OK AT IPR IPR 0 20 300 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600 OK H330 Module AT Command User Manual Page 176 of 304 Bs FIBOCOM 10 1 3 amp K RTS CTS Flow Control This command configures the flow control RTS Request To Send is an input line The RTS signal is received from the terminal and a low level indicates that H330 can send more data CTS Clear To Send is an output line The CTS signal is sent to the terminal and a low level indicates that more data can be sent to H330 The RTS and CTS line together make up what is called RTS CTS or hardware flow control Both lines are used when hardware flow control is enabled in both the terminal and the H330 devices When the terminal is ready and able to receive data it puts the RTS line in an active low condition to indicate this to the H330 If the terminal is not able to receive data typically because its receive buffer is almost full it puts the RTS line in an inactive high condition as a signal to the H330 to stop sending data When the terminal is ready to receive more data for example after data h
5. lt destination port range gt Consists of dot separated numeric 0 65535 parameters on the form f t lt source port range gt Consists of dot separated numeric 0 65535 parameters on the form f t lt ipsec security parameter index spi gt Hexadecimal parameter value range from 00000000 to FFFFFFFF lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt Dot separated numeric 0 255 parameters on the form t m Hexadecimal parameter value range from 00000 to FFFFF Valid for Ipv 6 only lt evaluation precedence index gt Numeric parameter value range from 0 to 255 Example AT CGTFT CGTFT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000000 0 0 00000 AT CGTFT CGTFT IP 1 8 0 255 0 0 0 0 0 0 0 0 255 255 255 255 255 255 255 255 0 255 0 0 65535 65535 0 0 65535 65535 00000000 ffffffff 0 0 255 255 00000 00000 OK H330 Module AT Command User Manual Page 244 of 304 Bs FIBOCOM 13 2 19 MGAUTH Set type of authentication This command allows to enter the type of authentication for a user name using a password for the specified PDP context Command Syntax Response Action Set AT MGAUTH lt cid gt lt auth gt lt name gt lt p OK wd gt eis CME ERROR lt err gt Read AT MGAUTH MGAUTH lt cid gt lt auth gt OK Test AT MGAUTH MGAUTH 1 10
6. lt mix_fac tor gt lt mix_factor gt integer indicating the kind of volume for tone generation range 1 7 lt result gt lt result gt integer indicating the overall result of the command may be 0 RESULT_OK 1 RESULT_PARAM_OUT_OF_RANGE 2 RESULT_DRV_NOT_SUPPORTED 3 RESULT_AUD_RESOURCE_NOT_AVAI L 4 RESULT OTHER ERROR H330 Module AT Command User Manual Page 204 of 304 Bs FIBOCOM lt aud_ret_code gt lt aud_ret_code gt integer value indicating the return code of the audio driver function call and may be 0 aud_rc_ok 1 aud_rc_resource_in_use 2 aud_rc_resource_conflict Ww aud_rc_handle_not_used A aud_rc_no_hw_support UI aud_rc_sharing_violation 6 aud_rc_parameter_out_of_range 7 aud_rc_audio_driver_disabled 8 aud_rc_missing_dsp_resou rces 10 aud_rc_format_not_supported 11 aud_rc_no_playback 12 aud_rc_unknown_position 13 aud_rc_request_error 14 aud_rc_syntax_error 15 aud_rc_tone_error 16 aud_rc_storage_problems 17 aud_rc_performance_problems 18 aud_rc_ram_buffer_used 19 aud_rc_suspend_resume_error 20 aud_rc_info 11 2 13 MMICG Microphone Gain Value This command handles the selection of microphone gain values of MIC The new value remains after power cycle Command Syntax Response Action Remarks H330 Module AT Command User Manual Page 205 of 304 Bs FIBOCOM The following table shows the M
7. lt level gt Description The default value is 4 0 7 Manufacturer specific volume range 0 is lowest volume not mute 11 2 3 CMUT Mute Unmute Microphone and Speaker Path This command is used to mute unmute the currently active Microphone and Speaker path by overriding the current mute state The CMUT setting should take effect only for the current call or for the next call once the command setting was typed in idle mode Command Syntax Response Action Remarks Set CMUT lt state gt OK The Set command ar enables disables uplink and downlink voice muting during a CME ERROR lt err gt voice call Read CMUT CMUT lt state gt The Read command returns the OK current uplink and downlink voice mute unmute state Test CMUT CMUT list of The Test command returns the supported lt state gt s possible lt state gt values OK H330 Module AT Command User Manual Page 194 of 304 Bs FIBOCOM The following table shows the CMUT parameters lt Parameter gt Description lt state gt 0 Unmute microphone and speaker path default 1 Mute microphone path Unmute speaker path 2 Unmute microphone mute speaker path 3 Mute microphone path mute speaker path Example AT CMUT CMUT 0 3 OK AT CMUT CMUT 0 uplink voice is unmuted OK AT CMUT 1 uplink voice is muted OK AT CMUT CMUT 1 OK AT CMUT 4 CME ERROR lt err gt 11 2 4 S94 Sidet
8. After issuing the Dial command and if the remote modem answers the call the two modems send high pitched carrier tones to one another which establish the transmission speed and other parameters for the data connection This process is called negotiation After the negotiation process the message CONNECT followed by the connection speed is received If the other phone line is busy the message BUSY is received If the other modem does not answer the message NO CARRIER is received Once a connection has been established the modem is ready to immediately begin transmitting and receiving data This may vary from sending messages to each other sending or receiving files logging on to an information service or any other data communication task you wish to perform 5 1 2 Switching From Data Mode to Command Mode To switch the connection from Data mode to Command mode send the Escape Sequence command If the modem responds with OK to the Escape command the modem is in Command mode and the dial connection is still active and you can use the AT command set H330 Module AT Command User Manual Page 43 of 304 Bs FIBOCOM Note e The character in the Escape Sequence pattern can be changed using the S2 S register e Escape is detected only by the H330 and not by the remote side The remote side stays in the Data mode e The behavior of Escape Sequence command is affected by AT amp D setting Plea
9. Anumeric parameter that indicates whether the UMTS bearer shall provide in sequence SDU delivery or not 0 no 1 yes 2 subscribed value Other values are reserved lt SDU error ratio gt a string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQREQ 5E3 0E0 means subscribed value refer 3GPP TS 24 008 subclause 10 5 6 5 lt Residual bit error ratio gt a string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQREQ 5E3 OEO means subscribed value refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery of erroneous SDUs gt a numeric parameter that indicates whether SDUs detected as erroneous shall be delivered or not 0 no 1 yes H330 Module AT Command User Manual Page 232 of 304 Bs FIBOCOM 2 no detect 3 subscribed value Other values are reserved lt Transfer delay gt a numeric parameter 0 1 2 that indicates
10. CGEQREQ IP 0 4 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps O 1 10 1500 1502 1510 1520 1E6 1E5 1E4 1E3 7E3 1E2 1E1 6E8 1E6 1E5 1E4 T 5E3 4E3 1E3 5E2 1E2 0 2 10 150 in 10 ms steps 200 950 in 50 ms steps 1000 4000 in 50 ms steps 0 3 0 1 0 1 OK H330 Module AT Command User Manual Page 233 of 304 Bs FIBOCOM 13 2 13 CGEQNEG G Quality of Service Profile Negotiated This command allows the TE to retrieve the negotiated QoS profiles returned in the Activate PDP Context Accept message Command Syntax Response Action Remarks Set AT CGEQNEG CGEQNEG lt cid gt lt Traffic class gt lt Maximum Set command lt cid gt lt cid gt bitrate UL gt lt Maximum bitrate allows the TE to ell DL gt lt Guaranteed bitrate UL gt lt Guaranteed retrieve the bitrate DL gt lt Delivery order gt lt Maximum Geena aoe SDU size gt lt SDU error ratio gt lt Residual bit profiles returned in error ratio gt lt Delivery of erroneous tne Avan DE SDUs gt lt Transfer delay gt lt Traffic handling SOMEXERCCEDE priority gt lt CR gt lt LF gt CGEQNEG lt cid gt message
11. H330 Module AT Command User Manual Page 167 of 304 Bs FIBOCOM 9 1 10 MCELL H330 Cell Description This command only support when module register GSM net UMTS not supported This command displays information about the Cellular Network The information is divided throughout 20 screens each of them with different parameters data Command Syntax Response Action Remarks Set MCELL lt mo OK The Set command will return OK de gt only The relevant lt screen_info gt lt screen_num gt will return back with MCELL or format few senconds later CME ERROR lt err gt Read MCELL OK The Read command just returns OK and does nothing Test MCELL MCELL list of supported The Test command returns the lt mode gt s list of possible lt mode gt amp lt screen_num gt supported values lt screen_num gt s OK The following table shows the MCELL parameters lt Parameter gt Description lt mode gt 0 One shot requested lt screen_num gt The requested screen number An integer number 1 Serving Idle Information screen 2 Circuit Switched Serving Cell Information screen 3 Miscellaneous Information screen 4 Uplink Data Transfer screen 5 Downlink Data Transfer screen 6 Neighbor 1 Cell Information screen 7 Neighbor 2 Cell Information screen 8 Neighbor 3 Cell Information screen 9 Neighbor 4 Cell Information screen 10 Neighbor 5 Cell Information screen 11 Neighbor 6 Cell Info
12. gt This is the message body lt CTRL Z gt _ lt CTRL Z gt ends the prompt text mode and returns to regular AT command mode CMGW 126 OK AT CMGW gt TEST lt CTRL Z gt CMGW 195 OK AT CMGF 0 OK AT CMGW 24 gt 079179521201009511FF0B917962543940F20008001400410042004300440045 lt CTRL Z gt CMGW 128 OK AT CMGR 128 CMGR 2 24 079179521201009511FF0B917962543940F 2000800140041 0042004300440045 OK H330 Module AT Command User Manual Page 134 of 304 Bs FIBOCOM AT CMGF 1 OK AT CSDH 1 OK AT CMGR 128 CMGR STO UNSENT 97264593042 145 17 0 8 0 972521100059 145 5 00410042004300440045 OK AT CSMP 25 05 03 15 21 22 23 08 0 0 OK AT CMGW 0544565034 A lt CTRL Z gt CMGW 129 OK AT CMGR 129 CMGR STO UNSENT 0544565034 129 25 0 0 05 03 15 21 22 23 08 972521100059 145 1 OK AT CMGF 0 OK AT CMGR 129 CMGR 2 20 0791795212010095 19FF0A81504465054300005030511 22232800141 AT CMGW 18 gt 0011000c917952428650290004AA0441 424344 SCA is not given CMGW 130 OK AT CMGR 130 CMGR 2 18 079179521201009511000C91 7952428650290004AA0441 424344 OK AT CMGW 19 gt 079179521201009511000c917952428650290004AA044 1424344 Invalid length 19 CMS ERROR invalid PDU mode parameter AT CMGW 19 gt 079179521201009511000c917952428650290004AA044 142434477 UDL is not equal to UD length CMS ERROR invalid PDU mode parameter AT CMGW 17 gt 07917952120100950100
13. lt Parameter gt Description lt index gt 1 352 Index of message in storage lt stat gt Status of message in memory PDU mode Text mode Description 0 REC UNREAD Received unread messages 1 REC READ Received read messages 2 STO UNSENT Stored unsent messages 3 STO SENT Stored sent message 4 ALL All messages For fault tolerance Two mode can be trade off lt oa da gt Original destination address lt data gt Message contents in text mode siaii In PDU mode Size of message i octets excluding SMSC data InTEXT mode Number of characters included in lt data gt spdis Message header and contents in PDU mode format See description in CMGR Read Message lt toda toda gt Type of origination address destination address lt fo gt First octet of the SMS lt mr gt Message Reference H330 Module AT Command User Manual Page 127 of 304 Bs FIBOCOM lt ra gt Recipient Address lt tora gt Type of Recipient address lt scts gt Service center time stamp lt ct gt Command type lt sn gt Message serial number lt mid gt Message ID lt page gt Current page number lt pages gt Total number of pages lt dt gt Discharge Time lt st gt Status Example AT CMGL CMGL REC UNREAD REC READ STO UNSENT STO SENT ALL OK AT CPMS SM _ read messages from SIM CPMS 2 20 11 61 2 20 OK AT CMGL read rec
14. nterrogate reason all call forwarding for all classes CME ERROR no network service Interrogation of lt reason gt 30 is not supported by network AT CCFC 2 3 972545658278 OK AT CCFC 2 0 Disable call forwarding for reason no reply of all classes OK AT CCFC 2 2 CCFC 0 1 972545658278 145 25 CCFC 0 2 972545658278 145 25 CCFC 0 4 972545658278 145 25 OK 5 3 13 CLIR Calling Line Identification Restriction This command instructs the H330 to query enable or disable the presentation of the CLI calling line ID of a MO call to the called party The restriction of the CLI disable presentation is dependent both on the H330 and on the network The network enables three possible provisions of CLIR Not provisioned CLIR Off presentation allowed Provisioned permanently Provisioned with Temporary mode The provision is fixed and cannot be changed by an AT command Temporary Mode H330 Module AT Command User Manual Page 63 of 304 Bs FIBOCOM Temporary mode can be in one of two states A Presentation restricted CLIR On as default B Presentation allowed CLIR Off as default A subscriber to Temporary mode always has a default subscription to state A or B Temporary mode provisioning means that the terminal can request the H330 to switch the default mode from A to B and vice versa Note When aservice is in state A and the terminal wants to enable the CLI presentation turn CLIR off
15. 000009 OK CCCM 00000e CCCM 000016 AT CAOC CAOC 00001d OK CCCM 00001e CCCM 000027 AT CAOC 0 CAOC 00002d OK H330 Module AT Command User Manual Page 78 of 304 Bs FIBOCOM AT CAOC 2 OK CCCM 00003d AT CAOC CAOC 00003 OK CCCM 000046 AT CCCM 00004e CAOC CAOC 00004f OK CCCM 000056 AT CAOC CAOC 00005d OK CCCM 00005e NO CARRIER AT CAOC CAOC 000066 OK 567 prepaid SIM value 102 price per call unit by provider x 66 call units 465 left in prepaid SIM OK There is now 46500 00L prepaid remaining on the SIM card Note The above example shows first time activation of the AOC feature using the H330 Therefore the accumulated cost is equal to the current call cost 5 5 2 CACM Accumulated Call Meter This command resets the Advice of Charge accumulated call meter value in the SIM file EFACM ACM contains the total number of home units for both the current call and preceding calls Command Syntax Response Action Remarks Set CACM OK The Set command resets the w CME ERROR lt err gt ae call meter value SIM PIN2 Read CACM CACM lt acm gt The Read command displays the current CME ERROR lt err gt Value of ACM H330 Module AT Command User Manual Page 79 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test CACM OK The Test command indicates wh
16. XXX is ASYNC SYNC REL H330 Module AT Command User Manual Page 51 of 304 Bs FIBOCOM GPRS SYNC REL ASYNC lt PDP_type gt lt PDP_addr gt lt L2P gt L lt A alternating voice data voice first BS 61 PN gt VGC lt GCA gt lt Gid gt lt ackflag gt lt priority gt VBC alternating voice data data first BS 61 lt GCA gt lt Gid gt lt ackflag gt lt priority gt GPRS network request for PDP context activation voice group call TS 91 voice broadcast call TS 92 The optional lt priority gt indicates the EMLPP priority level of the incoming call by paging notification or setup message lt subaddr gt string type subaddress of format specified by lt satype gt lt satype gt type of subaddress octet in integer format lt PDP_type gt lt PDP_addr gt and lt APN gt are as defined in the Define PDP Context CGDCONT command The optional lt L2P gt proposes a layer 2 protocol to use between the MT and the TE It is defined in the Enter GPRS Data Mode CGDATA command If the MT is unable to announce to the TE the network s request for example it is in V 250 online data state the MT shall reject the request No corresponding unsolicited result code shall be issued when the MT returns to a command state lt GCA gt is a part of the group call reference and indicates group call area lt Gid gt is a part of the group call reference and indicates group call identification The
17. e If lt ppu gt contains a dot a maximum of three digits may appear after the dot otherwise an error is generated For example if lt ppu gt 0 61 the Read command displays 0 610 lt ppu gt 1 2345 terminates in an error e If lt ppu gt does not contain a dot the number is divided by 1000 For example if lt ppu gt 1 the Read command displays 0 001 e Dueto storage constraints the lt ppu gt value is limited to a range of 0 to 4095 Values beyond this range may result in rounding errors For example if lt ppu gt 4095 the Read command displays 4 095 However if lt ppu gt 4096 the Read command displays 4 090 the last digit is replaced by 0 If lt ppu gt 456789 the Read command displays 456 000 5 5 5 CR Service Reporting Control This command controls whether or not the extended format of an outgoing call is displayed or not The CR indication is sent from the H330 to the terminal whenever a data call is initiated by the H330 Command Syntax Response Action Remarks Set CR lt mode gt OK The Set command enables disables the extended format of an outgoing data call When enabled the outgoing data call is indicated to the terminal through the unsolicited result code CR lt serv gt When the command is disabled no CR is sent to the terminal Read PER PER amode The Read command displays the current service OK reporting control setting Test CR CR lt mode gt The Test comma
18. lt Parameter gt Description lt service gt Indicates the service or service preference to be used 0 GPRS 1 Circuit switched default 2 GPRS preferred use circuit switched if GPRS is not available 3 Circuit switched preferred use GPRS if circuit switched is not available Other values are reserved and will result in an ERROR response to the Set command Example AT CGSMS CGSMS 0 3 OK AT CGSMS CGSMS 1 OK 7 1 20 CMGS Send SMS to Network This command sends an SMS from the H330 to the network The message reference value lt mr gt is returned to the H330 upon successful delivery of the message Valid lt toda gt will be any value between 128 255 The header parameters in TEXT mode will be set according to CSMP settings Command Syntax Response Action Remarks Set If text mode CMGS lt mr gt The Set command validates CMGF 1 the input parameters OK sends the SMS to network or and reports the result of the operation to the H330 CMGS lt da gt lt toda gt lt CR gt text is entered lt ctrl Z ESC gt CMGS ERROR lt err gt If PDU mode CMGF 0 CMGS lt length gt lt C R gt PDU is entered lt ctrl Z ESC gt H330 Module AT Command User Manual Page 138 of 304 Bs FIBOCOM The following table shows the CMGS parameters lt Parameter gt Description Saas Destination address in quoted string This field co
19. lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt Test AT CGEQNEG CGEQNEG list of lt cid gt s associated with Test command active contexts returns a list of lt cid gt s associated with active contexts The following table shows the CGEQNEG parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt Anumeric parameter that indicates the type of application for which the UMTS bearer service is optimised O0 conversational 1 streaming 2 interactive 3 background Other values are reserved lt Maximum bitrate UL gt A numeric parameter that indicates the maximum number of kbits s delivered to UMTS up link traffic at a SAP As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 H330 Module AT Command User Manual Page 234 of 304 Bs FIBOCOM lt Parameter gt Description lt Maximum bitrate DL gt A numeric parameter that indicates the maximum number of kbits s
20. lt alength gt lt slength gt lt elength gt SBD Ee ale gaa 2 J compound value and the maximum lengths of OK the lt number gt and lt text gt fields H330 Module AT Command User Manual Page 95 of 304 Bs FIBOCOM The following table shows the CPBR parameters lt Parameter gt Description lt index1 gt Index for a given phone book entry lt index2 gt lt number gt Phone number of a given entry lt type gt The address type of a phone number 129 Use for local call 145 Use for international access code 128 Unknown 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two lt text gt Text identifier for a phone book entry according to the character set as specified by command CSCS lt nlength gt The maximum number of digits in the lt number gt lt tlength gt The maximum number of characters in the lt text gt entry indicates if the entry is hidden or not only available if a UICC with an active USIM application is present 0 phonebook entry not hidden lt hidden gt 1 phonebook entry hidden string type field of maximum length lt glength gt character set as specified lt group gt by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt lt adtype gt type of address octet in integer format refer TS 24 00
21. lt index2 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt L lt a dnumber gt lt adtype gt lt secondtext gt lt email gt OK or CME ERROR lt err gt Test AT CPBF CPBF lt nlength gt L lt tlength gt lt glength gt lt slength gt lt elength gt OK H330 Module AT Command User Manual Page 97 of 304 Bs FIBOCOM The following table shows the CPBF parameters lt Parameter gt Description lt findtext gt Case sensitive text substring to search for according to the character set specified by the CSCS command lt index1 gt Index for a given phone book entry lt index2 gt lt number gt Phone number of a given entry lt type gt The address type of a phone number 129 Use for local call 145 Use for international access code 128 Unknown Note 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two lt text gt Text identifier for a phone book entry that starts with the substring lt findtext gt according to the character set as specified by command CSCS lt hidden gt indicates if the entry is hidden or not only available if a UICC with an active USIM application is present 0 phonebook entry not hidden 1 phonebook entry hidden lt group gt string type field of maximum length lt gleng
22. no information provided 0x65 0x81 Error memory failure 66 xx Security Error 0x66 OxXX Security Error 0x67 OxXX incorrect parameter P3 0x68 OxXX Check Error CLA function not supported 0x68 0x00 Check Error no information provided 0x68 0x81 Check Error logical channel not supported 0x68 0x82 Check Error secure messaging not supported 0x69 OxXX Check Error command not allowed H330 Module AT Command User Manual Page 36 of 304 Bs FIBOCOM 0x69 0x00 Check Error no information provided 0x69 0x81 Check Error command incompatible with file structure 0x69 0x82 Check Error security status not satisfied 0x69 0x83 Check Error authentication method blocked 0x69 0x84 Check Error referenced data invalidated 0x69 0x85 Check Error conditions of use not satisfied 0x69 0x86 Check Error command not allowed no current EF 0x69 0x87 Check Error expected SM data objects missing 0x69 0x88 Check Error SM data objects incorrect Ox6A OxXX Check Error wrong parameters 0x6A 0x00 Check Error no information provided 0x6A 0x80 Check Error incorrect parameters in data field 0x6A 0x81 Check Error function not supported 0x6A 0x82 Check Error file not found 0x6A 0x83 Check Error record not found 0x6A 0x84 Check Error not enough memory space in the file 0x6A 0x85 Check Error Lc inconsistant with TLV structure 0x6A 0x86 Check Error inconsistant parameters P1 P2 0x6A 0x87 Check Error Lc inconsistant wi
23. shows the MIPDSETS parameters lt Parameter gt Description Size Size of the buffer 128 lt size lt 2048 The default value is 2048 Time span 0 1000 The default value is 0 H330 Module AT Command User Manual Page 253 of 304 Bs FIBOCOM Example AT MIPDSETS 1 OK AT MIPDSETS 1912 MIPDSETS 1 4 128 2048 0 1000 OK 14 6 MIPSEND Send Data 14 6 1 Send Data at normal mode This command causes the H330 to store the data that the terminal provides in the accumulating buffer and then send this data using protocol stack when the amount of data reaches the predefined amount see MIPSETS Set Size and Timeout for Automatic Push on Before sending data a valid connection must be created using the MIPCALL and MIPOPEN commands Recommends that the terminal sets the watermark in the accumulating buffer prior to this command using the MIPSETS command By default the watermark is set to 2048 bytes of data Command Syntax Response Action Remarks Set MIPSEND lt S ERROR Data in the MIPSEND ocket_ID gt lt Da MIPSEND command is dnes to 1024 i lt Socket_ID gt lt status gt lt FreeSize characters 2048 in coded form gt Read MIPSEND MIPSEND lt Socket_ID gt lt FreeSize gt gt lt Sock et_ID gt FreeSize gt lt CR gt lt LF gt OK For all ACTIVE sockets The following table shows the MIPSEND parameters
24. 1 REC READ Received read messages 2 STO UNSENT Stored unsent messages 3 STO SENT Stored sent message 4 ALL All messages lt alpha gt Alpha ID of message not present In PDU mode Size of message in octets excluding SMSC data lt length gt In TEXT mode Number of characters included in lt data gt Message header and contents in PDU mode format lt pdu gt See description in the table below lt oa da gt Original destination address lt data gt Message contents in text mode lt toda toda gt Type of origination address destination address lt fo gt First octet of the SMS lt pid gt Protocol Identifer lt dcs gt Data Coding Scheme lt sca gt Service Center Address lt tosca gt Type of Service Center Address H330 Module AT Command User Manual Page 130 of 304 Bs FIBOCOM Validity Period Either in integer format or in time string format lt vp gt yy MM dd hh mm ss zz lt mr gt Message reference lt scts gt Service center time stamp lt ct gt Command type lt sn gt Message serial number lt mn gt Message Number lt cdata gt Command Data lt mid gt Message ID lt page gt Current page number lt pages gt Total number of pages lt mr gt Message reference lt ra gt Message Recipient address lt tora gt Type of Recipient address lt scts gt Service center time stamp lt dt gt Discharge Time lt st gt Status
25. 317 SIM PIN2 required 318 SIM PUK2 required 319 incorrect PUK1 320 memory failure 321 invalid memory index 322 memory full 330 SMSC address unknown 331 no network service 332 network timeout 340 no CNMA acknowledgement expected 512 MN_SMS_RP_ACK H330 Module AT Command User Manual Page 301 of 304 Bs FIBOCOM 513 MN_SMS_TIMER_EXPIRED 514 MN_SMS_FORW_AVAIL_FAILED 515 MN_SMS_FORW_AVAIL_ABORTED 516 MS invalid TP Message Type Indicator 517 MS no TP Status Report in Phase 1 518 MS no TP Reject Duplicate in Phase 1 519 MS no TP Reply Path in Phase 1 520 MS no TP User Data Header in Phase 1 521 MS missing TP Validity Period 522 MS invalid TP Service Centre Time Stamp 523 MS missing TP Destination Address 524 MS invalid TP Destination Address 525 MS missing Service Centre Address 526 MS invalid Service Centre Address 527 MS invalid alphabet 528 MS invalid TP User Data Length 529 MS missing TP User Data 530 MS TP User Data too long 531 MS no Command Request in Phase 1 532 MS Cmd Req invalid TP Destination Address 533 MS Cmd Req invalid TP User Data Length 534 MS Cmd Req invalid TP User Data 535 MS Cmd Req invalid TP Command Type 536 MN MNR creation failed 537 MS CMM creation failed 538 MS network connection lost 539 MS pending MO SM transfer 540 RP Error OK 541 RP Error OK no icon di
26. 3523D 313A544D3D MIPRTCP 2 370 313131393531343833323A4C4D3D313131393531343833323A533D644F656476 7A6C34765F7059475A384A3B20657870697265 733D53756E2C2031372D4A616E2D323033382031393 A31 343A30372047 MIPRTCP H330 Module AT Command User Manual Page 264 of 304 Bs FIBOCOM 2 290 4D543B20706174683D2F3B20646F 6D6 1696E3D2E676F6F676C652E636F 6 DOD0A436F6E74656E 74 2D547970653A20746578742F68746D6C0D0A5365727665723A204757532F322E310D0A436F6E74656 E MIPRTCP 2 210 742D4C656E6774683A203231370D0A446174653A205468752C203233204A756E203230303520 30383 MIPRTCP 2 130 484541443E3C5449544C453E333032204D6F7665643C2F5449544C453E3C2F484541443E3C424 F44 593E0A3C48313E333032204D6F 7665643C2F483 13E0A54686520646F63756D656E7420686173206D MIPRTCP 2 50 6F 7665640A3C41 20485245463D22687474703A2F 2F7777772E676F6F676C652E636F 2E696C2F63 786 665723F633D505245462533443A544D25334431 3131393531 343833323A5325334467384A637631 MIPRTCP 2 0 426A5458472D30636A5926616D703B707265763D2F 223E686572653C2F41 3E2EODOA3C2F424F44 593 E3C2F48544D4C3E0DOA MIPSTAT 2 1 40 14 14 MPING Start Ping Execution ICMP Protocol This command allows verifying IP connectivity to another remote machine computer by sending one or more Internet Control Message Protocol ICMP Echo Request messages The receipt of corresponding Echo Reply messages are displayed along with round trip times Valid IP address must be obtained using AT MIPCALL command prior to start
27. CRC is enabled the indication is CRING H330 Module AT Command User Manual Page 50 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set CRC lt n gt OK The Set command enables disables the extended format of an incoming call indication When enabled an incoming call is indicated to the terminal with an unsolicited result code CRING lt type gt instead of the normal RING pead PEREI PERE aN The Read command queries the current OK settings for the cellular result code Test CRC P E fees pone eas returns the possible RING CRING Indication CRING lt type gt or RING The following table shows the CRC parameters lt Parameter gt Description lt n gt 0 Extended format disabled 1 Extended format enabled The default value is 0 lt type gt Type of incoming call ASYNC asynchronous transparent L lt priority gt lt subaddr gt lt satype gt SYNC L lt priority gt lt subaddr gt lt satype gt synchronous transparent REL ASYNC L lt priority gt lt subaddr gt lt satype gt REL SYNC asynchronous non transparent L lt priority gt lt subaddr gt lt satype gt j VOICE L lt priority gt lt subaddr gt lt satype gt VOICE XXX synchronous non transparent L lt priority gt lt subaddr gt lt satype gt ALT VOICE XXX normal voice TS 11 L lt priority gt lt subaddr gt lt satype gt voice followed by data BS 81
28. Command Syntax Response Action Remarks Set AT CGQREQ lt cid OK The Set command specifies a profile for gt L lt precedence gt on the context identified by the local lt delay gt lt reliabili context identification parameter lt cid gt As ty gt L lt peak gt lt me CME ERROR lt err gt this is the same parameter that is used in an gt the CGDCONT command the CGQREQ command is effectively an extension of the CGDCONT command The QoS profile consists of a number of parameters each of which may be set to a separate value A special form of the Set command CGQREQ lt cid gt causes the requested profile for context number lt cid gt to become undefined Read AT CGQREQ CGQREQ The Read command returns the current lt cid gt lt precedence gt settings for each defined context lt delay gt lt reliability gt lt peak gt lt mean gt OK Test AT CGQREQ CGQREQ The Test command returns values SPDP ty 0erllist or supported as a compound value If the ME supported lt preceden supports several PDP types the parameter value ranges for each PDP type are returned on a separate line The following table shows the CGQREQ parameters lt Parameter gt Description lt cid gt Anumeric parameter that specifies a particular PDP context definition The value is from 1 to 10 lt precedence gt Anumeric parameter that specifies the precedence class lt delay gt Anumeric para
29. FTPLIST lt result gt or file directory path optional The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 data follows Read FTPLIST ERROR Not supported Test FTPLIST FTPLIST Return command format lt file directory name gt OK The following table shows the FTPLIST parameters lt Parameter gt Description length is 255 octets File directory name This is a valid path and file standard in the server system string the max File name to Rename as string the max length is 255 octets Example AT FTPLIST FTPINFO TYPEA OK FTPINFO 200 Switching to ASCII mode FTPINFO PASV FTPINFO 227 Entering Passive Mode 183 232 65 2 168 231 FTPINFO LIST FTPLIST 2 rW r r 1 602 404 184 Jul 14 08 17 1234 txt aW 1 602 404 92 Jul 14 08 12 12345 txt H330 Module AT Command User Manual Page 284 of 304 Bs FIBOCOM rWw r r 1 602 404 1048663 Jul 13 10 10 1M drwxr xr x 2 602 404 4096 Jul 13 03 45 TEST drwxr xr x 2 602 404 4096 Jul 13 08 25 ghttest FTPINFO 150 Here comes the directory listing FTPINFO 226 Directory send OK FTPLIST 1 15 13 FTPSTAT Request Status This command can send out a status as a response by control connection Note This command can include a parameter field if a complete path name is specified STAT is similar with LIST command except th
30. H330 Module AT Command User Manual Page 261 of 304 Bs FIBOCOM MIPRUDP unsolicited event coming if you do not specify IP and port using MIPPUSH data left in the buffer will be sent to this new destination by default e If IPRFMT parameter has been set by AT GTSET the received data will be reponse at different format Example MIPRTCP 3 0 7171 14 12 MIPSTAT Status Report This unsolicited event is sent to the terminal indicating a change in status Currently there are two possible sources of failure a broken logical connection or a broken physical connection Syntax MIPSTAT lt socket_ID gt lt n gt lt number_of_acknowledged_bytes gt The following table shows the MIP STAT parameters lt Parameter gt Description lt Socket_ID gt A unique number that identifies a connection Valid socket numbers 1 2 3 and 4 lt n gt 0 ACK indication 1 Broken protocol stack 2 Connection closed automatically due to non fatal alert lt number_of_acknowledged_bytes gt Total number of bytes that were acknowledged Example MIPSTAT 1 2 14 13 MIPCONF Configure Internal TCP IP stack This command allows configuring TCP stack parameters such as retransmissions number upper and bottom limits of retransmission timeout close delay It can be used to configure TCP socket parameters before socket activation Configuration values will be stored in H330 module until power cyc
31. ME message storage SR status report storage Example AT CPMS SM CPMS 5 50 5 50 5 50 OK AT CPMS CPMS SM 5 50 SM 5 50 SM 5 50 OK 7 1 3 CMGF Message Format This command is a basic command The Set command handles the selection of the message format used with send list read and write commands as well as the format of unsolicited result codes resulting from message receipts The H330 supports both PDU mode where entire TP data units are used and text mode where the body of the message and its headers are given as separate parameters Command Syntax Response Action Remarks Set CMG OK The Set command sets the message F lt m format to use or ode gt CMS ERROR lt err gt H330 Module AT Command User Manual Page 107 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read Tee FCMIGE lt iodes The Read command displays the Pe OK current message format Test CMG CMGF list of supported mode gt s The Test command lists all the F OK supported message formats The following table shows the CMGF parameters lt Parameter gt Description lt mode gt Message format 0 PDU mode default 1 Text mode Example AT CMGF 1 OK AT CMGF CMGF 1 OK AT CMGF CMGF 0 1 OK 7 1 4 CSCA Service Center Address This command enables to write read SCA to from SIM In SMS text mode SCA stored in SIM is added to a
32. a gt Note This command is activated if Advice of Charge is supported by the network H330 Module AT Command User Manual Page 80 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read CAMM CAMM zammas The Read command displays the current value of ACMmax OK Test CAMM OK The Test command indicates whether the CAMM command is functioning The following table shows the CAMM parameters lt Parameter gt Description lt acmmax gt Accumulated call meter maximum value similar to CCM Refer to CAOC Advice of Charge lt ccm gt String type three bytes of the current call meter value in hexadecimal format for example 00001E indicates a decimal value of 30 Value is given in home units bytes are similarly coded as the ACMmax value in the SIM Range is from 00001 to FFFFFF 0 Disables ACMmax default lt passwd gt SIM PIN2 password Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR incorrect password is displayed Example AT CAMM OK AT CAMM FFFFFF 2222 OK AT CAMM CAMM FFFFFF OK H330 Module AT Command User Manual Page 81 of 304 Bs FIBOCOM 5 5 4 CPUC Price per Unit and Currency Table This command sets the parameters of the Advice of Charge related price per unit and currency table found in the SIM file EFPUCT PUCT information is used to c
33. for a single call it can do so using the ATD command This does not change the Temporary mode state This can also be done when the service is in state B and the terminal wants to disable the CLI presentation turn CLIR on for a single call Command Syntax Response Action Remarks Set CLIR lt n gt OK The Set command instructs the H330 to Sr enable disable CLI restriction for all MO l calls CME ERROR lt err gt Read CLIR CLIR lt n gt lt m gt The Read command returns the current OK setting of CLIR on the network lt m gt and on the H330 lt n gt Test CLIR CLIR list of The Test command returns lt n gt values supported lt n gt s supported by the H330 The following table shows the CLIR parameters lt Parameter gt Description lt n gt Adjustment for outgoing calls 0 Presentation indicator is used according to the subscription of the CLIR service 1 CLIR invocation 2 CLIR suppression The default value is 2 lt m gt Subscriber CLIR service status in the network 0 CLIR not provisioned 1 CLIR provisioned in permanent mode 2 Unknown for example no network and so on 3 CLIR Temporary mode presentation restricted can be the default 4 CLIR Temporary mode presentation allowed can be the default Example AT CLIR H330 Module AT Command User Manual Page 64 of 304 Bs FIBOCOM CLIR 0 2 OK AT CLIR CLIR 0 0 AT CLI
34. lt Parameter gt Description 0 disable network registration attach status unsolicited result code a 1 enable network registration attach status unsolicited result code XREG lt State gt 0 not registered registered HSDPA attached with DFS22 21 00 DFSD23 09 01 registered HSUPA attached with DFS22 21 00 DFSD23 09 01 registered HSUPA and HSDPA attached H330 Module AT Command User Manual Page 166 of 304 Bs FIBOCOM lt Band gt 900 selection of 900 MHz band 1800 selection of 1800 MHz band 1900 selection of 1900 MHz band 850 selection of 850 MHz band 450 selection of 450 MHz band 480 selection of 480 MHz band 750 selection of 750 MHz band 380 selection of 380 MHz band 410 selection of 410 MHz band 710 selection of 710 MHz band 810 selection of 810 MHz band BAND_UMTS_I BAND_UMTS_ BAND_UMTS_Il BAND_UMTS_II BAND_UMTS_IIl BAND_UMTS_III BAND_UMTS_IV BAND_UMTS_IV BAND_UMTS_V BAND_UMTS_V BAND_UMTS_VI BAND_UMTS_VI BAND_UMTS_VII BAND_UMTS_VII BAND_UMTS_VIII BAND_UMTS_VIII BAND_UMTS_IX BAND_UMTS_IX BAND_UMTS_X BAND_UMTS_X BAND_UMTS_XI BAND_UMTS_XI BAND_UMTS_XII BAND_UMTS_XII BAND_UMTS_XIIl BAND_UMTS_XIII BAND_UMTS_XIV BAND_UMTS_XIV BAND_UMTS_XV BAND_UMTS_XV BAND_UMTS_XVI BAND_UMTS_XVI BAND_UMTS_XVII BAND_UMTS_XvVII BAND_UMTS_XVIII BAND_UMTS_XVIII BAND_UMTS_XIX BAND_UMTS_XIX BAND_UMTS_XX BAND_UMTS_XX BAND_UMTS_XXI BAND_UMTS_XxXI BAND_UMTS_XXII BAND_UMTS_XxII
35. lt ackflag gt 1 proposes that a predefined confirmation procedure is to be used after the call is ended For lt ackflag gt 0 no confirmation procedure is required Example AT CRC CRC 0 OK H330 Module AT Command User Manual Page 52 of 304 Bs FIBOCOM AT CRC CRC 0 1 OK Example RING CRING indication Incoming Data Call RING RING RING AT CRC 1 Enable extended ring format OK CRING REL ASYNC CRING REL ASYNC ath OK AT CRC 1 OK CRING ALT Voice Data NO CARRIER 5 3 7 CLIP Calling Line Identification This command controls the Calling Line Identity CLI presentation indication to the terminal when an incoming call is detected by the H330 This command allows the user to query the provisioning status of the CLI by the network and by the H330 The command also allows the user to enable disable the CLI presentation by the H330 to the terminal The CLIP indication information varies depending on what is provided by the network and what information is stored in the H330 phone book Command Syntax Response Action Remarks Set AT CLIP lt OK The Set command enables or disables n gt a the presentation of the CLI indication from the H330 to the terminal CME ERROR lt err gt Note The Set command does not address the network Read AT CLIP CLIP lt n gt lt m gt The Read command returns the CLIP enable disable state in the H330 as well as in the netwo
36. lt m gt 1 and a supplementary service notification is received during a mobile terminated call setup or during a call or when a forward check supplementary service notification is received the unsolicited result code CSSU is sent to the TE In case of a mobile terminated call setup a CSSU is sent after every CLIP result code CLIP Calling Line Identification When several different events are received from the network each of them receives its own CSSU result code Note The values for lt n gt and lt m gt are not saved after power cycle Read FERSIN TORN SiS The Read command displays the current OK supplementary service notification setting H330 Module AT Command User Manual Page 84 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Tet CSSN 0 1 0 1 The Test command displays the list of i OK supported CSSN values The following table shows the CSSN parameters lt Parameter gt Description lt n gt Sets displays the CSSI result code presentation status This value must be specified 0 Disable default 1 Enable lt m gt Sets displays the CSSU result code presentation status This value is optional but cannot be specified without lt n gt 0 Disable default 1 Enable Value Description H330 Support 0 Unconditional call forwarding is active Yes 1 Some conditional c
37. values or STK ERROR lt err gt result codes and use numeric lt err gt values 2 Enable the CME ERROR lt err gt or CMS ERROR lt err gt result codes and use verbose lt err gt values or STK ERROR lt err gt result codes and use numeric lt err gt values The default value is 0 Example AT CMEE 0 CME ERROR is not used OK AT VTD ERROR AT CMEE 1 Use numeric lt err gt OK AT VTD CME ERROR 1 AT CMEE 2 Use verbose lt err gt OK AT VTD CME ERROR operation not supported H330 Module AT Command User Manual Page 41 of 304 Bs FIBOCOM 4 3 2 CEER Extended Error Report This execution command returns an extended error report containing one or more lines of information text lt report gt determined by the manufacturer providing reasons for the following errors Failure in the last unsuccessful call setup originating or answering or the in call modification Last call release Typically the text consists of a single line containing the reason for the error according to information given by GSM network in textual format Command Syntax Response Action Execute AT CEER CEER lt category gt lt cause gt lt description gt OK Test AT CEER OK The following table shows the CEER parameters lt Parameter gt Description lt category gt No report available CC setup error CC modification error CC release SM attach error
38. 0 0 CGEQMIN 4 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 3 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 CGEQMIN 2 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 OK AT CGEQMIN CGEQMIN IP 0 3 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 1 63 in 1 kbps steps 64 568 in 8 kbps steps 576 8640 in 64 kbps steps 8700 16000 in 100 kbps steps 0 1 10 1500 1502 1510 1520 1E6 1E5 1E4 1E3 7E3 1E2 1E1 6E8 1E6 1E5 1E4 5E3 4E3 1E3 5E2 1E2 0 2 10 150 in 10 ms steps 200 950 in 50 ms steps 1000 4000 in 50 ms steps 0 3 0 1 0 1 OK 13 2 12 CGEQREQ 3G Quality of Service Profile Requested This command allows the TE to specify a UMTS Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network L lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt L lt Transfer delay gt L lt Traffic handling priority gt lt Source statistics descriptor gt L lt Signalling indication gt NI Command Syntax Response Action Remark
39. 0 2 64 64 OK The following table shows the MGAUTH parameters Parameter Description cid PDP context identifier must be defined by AT CGDCONT firstly Range from 1 10 auth Authentication may be 0 Meaning authentication protocol not used NONE 1 Meaning personal authentication protocol PAP 2 Meaning handshake authentication protocol CHAP name User name as string with length pwd Password as string with maximum length Example at mgauth 1 1 gsm 1234 OK at mgauth MGAUTH 1 1 OK H330 Module AT Command User Manual Page 245 of 304 Bs FIBOCOM 14TCP IP 14 1 MIPCALL Create a Wireless Link This command sets up a PPP Point to Point Protocol connection with the GGSN Gate GPRS Support Node and returns a valid dynamic IP for the H330 Command Syntax Response Action Set MIPCALL lt Operation gt lt APN gt lt cid OK j MIPCALL lt local IP address gt or ERROR lt err gt MIPCALL 0 Read MIPCALL MIPCALL lt status gt lt IP gt Test MIPCALL MIPCALL list of supported lt operation gt s Notes The MIPCALL command does not have a general ABORT mechanism therefore a command cannot be issued until the previous command ends When a call exists the dynamic IP address will be returned For example AT MIPCALL MIPCALL 1 172 17 237 80 Activating a context can take up to 150 seconds Deactivating a c
40. Active and Waiting Call Single Active released waiting not affected MTPY Active and Waiting Call MTPY Active released waiting not affected Single or MTPY Active and Single or MTPY Held Single or MTPY Active released Held Single or MTPY and Waiting Call Waiting call released Single or MTPY Active and Single or MTPY Held amp Waiting call Single or MTPY Active released Example RING ncoming call RING Incoming call ath Hang up incoming call OK H330 Module AT Command User Manual Page 48 of 304 Bs FIBOCOM NO CARRIER Incoming call has been terminated user determined user busy RING ata OK NVoice call connected ath Hang up connected call OK NO CARRIER Active call has been hung up terminated Active multi party call with 3 numbers ath OK NO CARRIER NO CARRIER NO CARRIER atd035659260 OK ath Terminate MO voice call while placed OK NO CARRIER Example Hanging up a data call atd035659260 CONNECT Data call connected Online Data mode ESC Sequence is sent from the terminal to the H330 OK The H330 is in Command mode ath Terminate Data call OK NO CARRIER 5 3 5 A Answer Incoming Call This command answers an incoming VOICE DATA call after a RING CRING indication is sent to the terminal If the incoming call is answered CSD connected the H330 sends a CONNECT notification to the terminal
41. CLI validity gt The Validity of the Calling Line Identity presentation 0 CLI valid 1 CLI has been withheld by the originator 2 CLI is not available due to networking problems or limitations of the originating network Note When the parameter lt mode gt is 2 Query status the first parameter is ignored and the third parameter is always treated as class 1 unless it was set in Set Mode H330 Module AT Command User Manual Page 57 of 304 Bs FIBOCOM Example AT CCWA 1 Enable call waiting on H330 OK AT CCWA CCWA 0 1 OK AT CCWA CCWA 1 OK Examples of CCWA set command network interrogation AT CCWA 1 2 Class parameter is considered as 7 CCWA 1 1 Call waiting is active for class 1 voice OK AT CCWA 1 2 2 Class parameter is 2 CCWA 0 2 Call waiting is not active for class 2 data OK AT CCWA 1 1 OK Enable the call waiting feature in the network and in the H330 Example CCWA indication atd9311234567 Originate a voice call OK OK Noice call connected conversation call waiting indication received by the H330 CCWA 358317654321 145 1 Bob AT CHLD 0 Release the waiting call OK NO CARRIER AT CRC 1 RING indication is not relevant to CCWA indication OK waiting call caller restricted to its CLI presentation used AT CLIR CCWA 128 1 1 CLI is restricted but call type recognized as voice 5 3 11 CHLD
42. CME ERROR incorrect password AT CPBS FD lt pin2 longer then 8 chars gt CME ERROR text string too long 6 1 2 CPBR Read Phone Book Entries This command recalls phone book entries from a specific entry number or from a range of entries If only one entry is specified and that entry is empty OK is returned If a range of entries is requested all entries that contain data within that range are returned If a listing fails in a H330 error CME ERROR lt err gt is returned This command can also be used to obtain information about the number of entries and the maximum size of a phone number and alpha tag fields in the phone book This command acts on the currently active phone book as selected with the CPBS command Command Syntax Response Action Remarks Set CPBR CPBR The Set command lt index1 lt index1 gt lt number gt lt type gt lt text gt returns phone book gt L lt inde lt hidden gt lt group gt lt adnumber entries x2 gt gt L lt adtype gt lt secondtext gt lt em ail gt lt CR gt lt LF gt CPBR lt index2 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt lt adnumber gt L lt adtype gt lt secondtext gt lt em ail gt OK or CME ERROR lt err gt Test CPBR CPBR list of The Test command supported lt index gt s lt nlength gt returns the entry range lt tlength gt lt glength gt supported by the
43. CMS ERROR lt err gt when text format message mode is selected H330 Module AT Command User Manual Page 111 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read AT CSMP CSMP The read command returns the current lt fo gt lt vp gt lt pid gt lt dc parameters value s gt OK Test AT CSMP OK The test command just returns OK The following table shows the CSMP parameters lt Parameter gt Description lt fo gt First octet of GSM 03 40 Integer format For details see CMGW definitions The default value at power up is 17 Message type is SMS SUBMIT and relative VP format lt vp gt Validity Period depending on SMS SUBMIT lt fo gt TP Validity Period Format bits setting If there is no correlation between the VPF and the VP value an error message will be returned Either in integer format see Table or in time string format yy MM dd hh mm ss zz If in integer format the vp will write to SIM EF and read form SIM EF when use it lt pid gt Protocol Identifier The one octet information element by which the SM TL either refers to the higher layer protocol being used or indicates interworking with a certain type of telematic device 0 no interworking SME to SME protocol default Any value between 0 255 will be accepted The SC may reject messages with a TP Protocol Identifier containing a reserved value or one which is not supported
44. CPBW 1 8475763000 129 Lin Zhao OK AT CSCS UCS2 OK AT CPBR 1 CPBR 1 8475763000 129 004C0069006E0020005A00680061 006F OK 3 6 CIMI Request IMSI This command displays the International Mobile Subscriber Identity number Command Response Action AT CIMI CIMI lt imsi gt AT CIMI OK or CME ERROR lt err gt Example AT CIMI CIMI 314566320021400 OK H330 Module AT Command User Manual Page 20 of 304 Bs FIBOCOM 3 7 CFSN Read Factory Serial Number This command is used to query the factory serial number Command Response Action AT CFSN CFSN lt fsn gt AT CFSN OK Example AT CFSN CFSN 1234567890 OK 3 8 Request Identification Information This command displays various H330 information items Command Response Action ATIn lt information item n gt or CME ERROR lt err gt The following table shows the information items that are supported by the H330 ATIn Description Output Just Demo Remark ATI Same as ATIO Built Mar 23 2012 08 50 27 ATIO Build time Built Mar 23 2012 08 50 27 ATII Reserve Reserve ATI2 Reserve Reserve ATI3 Product description Fibocom HSPA Module ATI4 Reserve Reserve ATI5 Platform XMM6260 ATI6 Reserve Reserve ATI7 Product description H330 HSPA Module ATI8 Software version H330_V1H 00 09 ATI9 Reserve Reserve H330 Module AT Command
45. Description Indication status Enable disable FTP unsolicited indication the range of the value 0 1 Example at ftpinfo 1 enable unsolicited indication print OK AT FTPOPEN ftp adobe com anonymous ftpuser adobe com OK FTPINFO 220 ftp adobe com unsolicited indication returned by the server FTPINFO 220 Adobe Systems Inc FTPINFO 220 FTPINFO 220 By downloading software of Adobe Systems Incorporated or its FTPINFO 220 subsidiaries from this site you agree to the terms and FTPINFO 220 conditions described in ftp ftp adobe com license txt FTPINFO 220 FTPINFO 220 Web browser users Click on Web_User_Click_Here html FTPINFO 220 FTPINFO 220 FTP client users To connect use anonymous as the login FTPINFO 220 and use your e mail address as the password For example FTPINFO 220 login anonymous FTPINFO 220 password ftpuser adobe com FTPINFO 220 FTPINFO 220 FTPINFO 220 FTPINFO USER anonymous send username FTPINFO 331 Please specify the password please enter the password H330 Module AT Command User Manual Page 278 of 304 Bs FIBOCOM FTPINFO PASS ftpuser adobe com send password FTPINFO 230 Login successful FTPOPEN 1 15 5 FTPCWD Change Working Directory This command is used for changing the server s current working directory Command Syntax Response Action Remarks Set FTPCWD lt dire OK FTPCWD lt result gt lt directory_name gt parameter co
46. EchOmsenren ean E EE 26 4 1 4 X Result Code Selection and Call Progress Monitoring Control ssssssssssssssssssssesessssssssssssssssseee 26 4 1 5 S Bit Map Regi Stels xxssicssccseccstassesSciecastadsdasSoasvensvacsscaustesstusssaseassSayessayesauseagesagetassastioes EEEE 27 4 1 6 SD a A 29 4 1 7 n A E AOE E T 29 H330 Module AT Command User Manual Page 4 of 304 Bs FIBOCOM 4 1 8 BM View Configuration csvesisccesccascuevcctusathcascsctasalccausschansacacasgctcavvecensehcossecebadsnstouctedonsesesavecacausvecauqsassabeccbes 30 4 1 9 amp F Set to Factory Defined Configuration sssssccssssccsssssccssescsssscssssescsssececsussessuseessnseeessseecssneeessnes 31 4 1 10 Z Reset to Default Configuration sesssssccssssscssussssssesesssecessussesssscesssecessueecssuccessseeessueeessueeessneeesees 31 AV amp W StOre User Profile ssissscsiscsesccanssavssuvecsnasscecavssecastescensseatcucesbausecesnsscasndececasecenavcecdusecosbesceassbecavecebassestie 32 4 1 12 amp Y Default User Provtile sisssssscsncccanusavesavecanniececavececossesctnsseassucsctassecesnsscanndevecasesenasbcesevssecossescessseacavecerasauetibc 33 4 1 13 CRSM Restricted SIM ACCESS sscsssscsssccnesccnesssnesccneescsscscsscesssessssesssscsnsssensssensesenecessscsenecssnsessseessesess 33 4 1 14 GTUSIM Checks for USIM Card ssssscsssssccsssssesssssessussessnsessssscsssnscsssnccesnsccessnseessnseessnscesssseessaneesssues 38 AVS AC E B EA EE E A E O S 38 4 2 Sle
47. F amp F 0 OK 4 1 10 Z Reset to Default Configuration This command drops the current call and resets the values to default configuration Command Syntax Response Action Remarks Set ATZ lt val OK ue gt or CMS ERROR lt err gt Read ERROR The Read command for Z is not defined and therefore is not supported by the H330 The H330 returns an error Test ERROR The Test command for Z is not defined and therefore is not supported by the H330 The H330 returns an error H330 Module AT Command User Manual Page 31 of 304 Bs FIBOCOM The following table shows the Z parameters lt Parameter gt Description lt value gt 0 Set to user profile 0 1 Set to user profile 1 The default value is 0 Example ATZO OK 4 1 11 amp W Store User Profile This command saves in internal memory from the active profile to one of two user profiles Note The user must power off the module in regular process Otherwise this command cannot be in effect Command Syntax Response Action Remarks Set amp WI lt n gt OK Set command stores the current active oi configuration to user profile O or 1 CME ERROR lt err gt The following table shows the amp W parameters lt Parameter gt Description lt n gt User s profile number 0 Store to user s profile 0 1 Store to user s profile 1 Example AT amp WO OK AT amp W1 OK H330 Modu
48. FIBOCOM Example AT MAVOL MAVOL 1 1 4 MAVOL 1 2 1 MAVOL 1 4 4 OK AT MAVOL MAVOL 1 3 1 7 0 7 OK AT MAVOL 1 7 3 OK AT MAVOL MAVOL 1 1 3 MAVOL 1 2 3 MAVOL 1 4 3 OK AT MAVOL 3 7 3 OK Modified all the features in the 1st channel Modified all the features within the 1st channel and 2nd channel 11 2 12 MATONE Start or stop the tone play This command can play tone and stop play Command Syntax Response Action Set MATONE lt state gt lt tone_id OK gt lt nof_play_times gt lt mix_fa p c tor gt CME ERROR lt err gt Read MATONE MATONE lt result gt lt aud_ret_code gt OK Test MATONE MATONE lt state gt lt tone_id gt lt nof_play_times gt lt mix_fac tor gt OK H330 Module AT Command User Manual Page 202 of 304 Bs FIBOCOM The following table shows the MATONE parameters lt Parameter gt Description lt state gt 0 stop When state 0 lt tone_id gt 0 lt nof_play_times gt 0 lt mix_factor gt 0 means the tone is stop 1 start lt tone_id gt lt tone_id gt integer indicating the audio tone ID and may be 0 aud_tone_DTMF_0O 1 aud_tone_DTM F_1 2 aud_tone_DTMF_2 3 aud_tone_DTMF_3 4 aud_tone_DTMF_4 5 aud_tone_DTMF_5 6 aud_tone_DTMF_6 7 aud_tone_DTMF_7 8 aud_tone_DTMF_8 9 aud_tone_DTMF_9 10 aud_tone_DTM F_hash 11 aud_tone_DTMF_asterix 12 uta_audio_key_tone_1 13 uta
49. High gt For lt Report gt 1 MTSM lt Temp gt OK For lt Report gt 2 or 3 OK MTSM lt Temp gt MTSM lt Temp gt or ERROR lt error code gt H330 Module AT Command User Manual Page 185 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read MTSM MTSM lt Report gt lt Rate gt lt Low gt Read the setting lt High gt parameters OK Test MTSM MTSM range of lt Report gt range of lt Rate gt range of lt Low gt lt High gt OK The following table shows the MTSM parameters lt Parameter gt Description lt Temp gt 40 125 Temperature measurements in Celsius degrees lt Report gt 0 Deactivate unsolicited report 1 Report once the current temperature 2 Activate unsolicited report 3 Activate unsolicited report only for out off boundaries events 6 Report the temperature of BBIC 7 Report the temperature of RF 8 Report the temperature of PCB Not support yet 9 Report the temperature of BAT lt Rate gt 1 255 Select the time interval in seconds between the unsolicited reports Default value 1 Second lt Low gt 0 125 The lowest boundary level of the temperature value for unsolicited report Default value 0 Celsius Setting corresponding lt Low gt and lt High gt temperature boundaries for lt Report gt 3 only lt High gt 0 125 The Highest boundary level of the tem
50. MT is waiting SIM PUK2 to be given this lt code gt is recommended to be returned only when the last executed command resulted in PUK2 authentication failure i e CME ERROR 18 if PUK2 and new PIN2 are not entered right after the failure it is recommended that MT does not block its operation PH NET PIN MT is waiting network personalization password to be given PH NET PUK MT is waiting network personalization unblocking password to be given PH NETSUB PIN MT is waiting network subset personalization password to be given PH NETSUB PUK MT is waiting network subset personalization unblocking password to be given PH SP PIN MT is waiting service provider personalization password to be given H330 Module AT Command User Manual Page 144 of 304 Bs FIBOCOM PH SP PUK MT is waiting service provider personalization unblocking password to be given PH CORP PIN MT is waiting corporate personalization password to be given PH CORP PUK MT is waiting corporate personalization unblocking password to be given SIM PIN AT CPIN lt pin gt SIM PUK AT CPIN lt puk gt lt newpin gt SIM PUK2 AT CPIN lt puk2 gt lt newpin2 gt SIM PIN 2 AT CPIN lt pin2 gt Example AT CPIN OK AT CLCK SC 1 lt correct PIN gt Not case sensitive OK The facility is enabled by the CLCK command Refer to CLCK Facility Lock AT CPIN CPIN SIM PIN OK AT CPIN lt correct PIN gt OK AT CPIN CPIN READY OK The stat
51. O_SOMp gt It will be read only OK without lt h_comp gt l lt pd1 gt L any set command pdN OK Test AT CGDCONT CGDCONT range of The Test command returns the values supported as a compound value If the ME supports several PDP types lt PDP_type gt the parameter value ranges for each lt PDP_type gt are returned ona separate line The following table shows the CGDCONT parameters lt Parameter gt Description lt cid gt Numeric parameter specifying a particular PDP context definition PDP Context Identifier The parameter is local to the Terminal Mobile Terminal interface and is used in other PDP context related commands The value is from 1 to 10 lt PDP_type gt String parameter in quotation marks specifying the type of packet data Packetdata protocol IP protocol type IP Internet Protocol IETF STD 5 IPV6 Internet Protocol version 6 IETF RFC 2460 lt APN gt Access Point Name String parameter in quotation marks which is a logical name that is used to select the GGSN or the external packet data network If the value is null or omitted the subscription value is requested lt PDP_address gt String parameter in quotation marks which identifies the ME in the address space applicable to the PDP H330 Module AT Command User Manual Page 211 of 304 Bs FIBOCOM If the value is null or omitted a value may be provided by the term
52. PDP context was deactivated and the IP address is cancelled The default value is 1 10 1 6 amp D Circuit 108 Behavior This command determines how the H330 responds when the DTR Data Terminal Ready status is changed from ON to OFF during the online data state DTR is an input line that indicates that the terminal is ready The DTR line must be active low for the H330 to recognize the terminal This signal is raised by the terminal when a process activates the serial port If DTR is not used by the application it should connect this line to ground DTR active The default value is active low In case of local link during initial PPP retries DTR change will be ignored H330 Module AT Command User Manual Page 179 of 304 Bs FIBOCOM Command Syntax Response Action Set AT amp D lt param gt OK Read AT amp D amp D lt param gt Test AT amp D amp D list of supported lt param gt s The following table shows the amp D parameters lt Parameter gt Description lt param gt In CSD calls H330 s reaction when the DTR status is changed from ON to OFF 0 Ignore DTR changes 1 Switches the CSD call to asynchronous command mode the call remains connected 2 Disconnects the call and returns to the command mode In GPRS calls The behavior of is same as DTR signal changed from ON to OFF 0 Ignore DTR changes and command 1 Switch the GPRS
53. PDU in PDU mode Example AT CNMI 2 2 OK AT CMSS 142 054565132 send to myself CMSS 74 OK CMT 97254565132 03 04 09 17 14 33 08 new message text AT CNMA OK AT CNMI CNMI 2 2 0 0 OK AT CNMI 1 0 0 1 OK AT CSMP 49 167 OK AT CSMP CSMP 49 167 0 0 OK AT CNMI CNMI 1 0 0 1 0 OK AT CMSS 295 CMSS 184 OK H330 Module AT Command User Manual Page 119 of 304 Bs FIBOCOM CDS 6 184 972524680592 145 05 08 02 17 19 23 08 05 08 02 17 19 24 08 0 AT CNMA OK AT CNMI CNMI 1 0 0 1 0 OK 7 1 9 CMTI Unsolicited Response New SMS DELIVER Receipt Indication The CMTI unsolicited response is sent to the TE upon receipt of a new SMS DELIVER SMS if the CNMI parameter lt mt gt is set to 1 Refer to CNMI New Message Indications to Terminal This unsolicited message indicates that a new SMS DELIVER message was received and is stored in location lt index gt CMTI lt mem gt lt index gt The following table shows the CMTI parameters lt Parameter gt Description lt mem gt Message memory space SM SIM memory storage lt index gt Location of the new message Example AT CNMI 2 1 OK AT CMGS 18 send to my self gt 079179521201009511000c917952428650290004AA044 1424344 CMGS 69 OK CMTI SM 4 7 1 10 CMT Unsolicited Response New SMS DELIVER Receipt The CMT unsolicited response is sent to the TE upon receipt of a
54. Profile Min Acceptable This command enables the terminal to specify the minimum acceptable profile which is checked by the ME against the negotiated profile returned in the Activate PDP Context Accept message Command Syntax Response Action Remarks Set AT CGQMIN lt cid gt lt precedence gt lt delay gt lt reliability gt lt peak gt lt mean gt OK or CME ERROR lt err gt The Set command specifies a profile for the context identified by the local context identification parameter lt cid gt As this is the same parameter that is used in the CGDCONT command the CGQMIN command is effectively an extension of the CGDCONT command The QoS profile consists of a number of parameters each of which may be set to a separate value Read AT CGQMIN CGOQOMIN lt cid gt lt precedence gt lt delay gt lt r eliability gt lt peak gt lt mean gt lt CR gt lt LF gt CGQMIN lt cid gt lt precedence gt lt delay gt lt r eliability gt lt peak gt lt mean gt L OK Or CME ERROR lt err gt The Read command returns the current settings for each defined context H330 Module AT Command User Manual Page 213 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CGQMIN CGQMIN lt PDP_type gt list of The Test command returns supported lt precedence gt s list the parameter value ranges of for eac
55. RST retransmission timeout occurred etc H330 Module AT Command User Manual Page 250 of 304 Bs FIBOCOM Example AT MIPCLOSE MIPCLOSE 1 4 0 2 OK AT MIPCLOSE MIPCLOSE 0 No opened sockets OK AT MIPCLOSE 1 OK MIPCLOSE 1 0 Socket 1 closed The remote side replies with ACK Need wait few seconds AT MIPCLOSE 1 1 MIPCLOSE 1 2 Socket 1 closed immediately The lt close type gt indicate 2 OK AT MIPCLOSE 3 The terminal closes the opened socket OK MIPCLOSE 3 1024 2 Socket 3 closed Ack indication enabled 1024 bytes were acked AT MIPCLOSE Sockets 1 and 2 are opened MIPCLOSE 1 2 OK 14 4 MIPSETS Set Size and Timeout for Automatic Push This command causes the H330 to set a watermark in the accumulating buffer and set timeout When the watermark is reached data is pushed from the accumulating buffer into the protocol stack Timeout is used to define interval of time between MIPSEND command and time when data will be automatically pushed from the accumulating buffer into the protocol stack Data chunks between the terminal and the H330 are limited to be smaller than 1024 bytes 2048 characters in coded form In order to reduce the overhead of sending small amounts of data over the air the H330 uses an accumulating buffer The terminal can specify a watermark within the accumulating buffer size limits to indicate how much data should be accumulated The data in accumula
56. The SIM card is unlocked only once the provided pin is verified as the SIM PIN If the required PIN determined by the error code returned from the requested operation or the Read command is SIM PUK or H330 Module AT Command User Manual Page 142 of 304 Bs FIBOCOM SIM PUK2 the second pin is required This second pin lt newpin gt is used to replace the old pin in the SIM card When entering the pin a lt new pin gt is not required A SIM card related error is returned if an AT command operation is unsuccessful due to a SIM card problem The following table shows the SIM card errors Error Description 10 SIM not inserted SIM Card is not inserted 11 SIM PIN required SIM Card waiting for SIM PIN to be entered 12 SIM PUK required SIM PIN is blocked 13 SIM failure SIM Card is permanently blocked 17 SIM PIN2 required SIM Card is waiting for SIM PIN2 to be entered 18 SIM PUK2 required SIM PIN2 is blocked Command Syntax Response Action Remarks Set AT CPIN OK The Set command sends the password to lt puk gt 5j the H330 that is necessary before it can be r l operated SIM PIN or SIM PUK If there is lt pin gt CME ERROR no PIN request pending no action is taken Sez towards the H330 and an error message lt newpin gt CME ERROR is returned to the terminal The Set command issued gives the code SIM PIN or SIM PUK corresponding to the error code required or returned as t
57. The set command requests the MT to esponse gt lt L2 Or respond to a network request for Packet P gt lt cid gt Domain PDP context activation which CME ERROR lt error gt has been signalled to the TE by the RING or CRING unsolicited result code Test AT CGANS CGANS list of The test command returns the values of supported lt response gt and lt L2P gt supported by lt response gt s list of the MT as compound values supported lt L2P gt s The following table shows the CGANS parameters lt Parameter gt Description lt response gt A numeric parameter which specifies how the request should be responded to 0 reject the request 1 accept and request that the PDP context be activated If lt response gt is omitted it is assumed to be 0 Other values are reserved and will result in the ERROR response lt L2P gt A string parameter which indicates the layer 2 protocol to be used see CGDATA command lt cid gt A numeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands The lt response gt parameter allows the TE to accept or reject the request If lt response gt is 0 the request is rejected and the MT returns OK to the TE If lt response gt is 1 the following procedure is followed by the MT Commands following the CGANS command in the AT command line shall not be processed by the MT If the lt L2P gt p
58. User Manual Page 21 of 304 Bs FIBOCOM 3 9 CNUM Request MSISDN s This command displays up to 2 strings of text information that identify the H330 The output string contains double quotes On SIM cards that have EFmsisdn file the string s returned are the MSISDN numbers and their associated data On SIM cards that don t have EFmsisdn file the strings returned are the MSISDN numbers and their associated data stored in H330 NVM Command Response Action CNUM CNUM CNUM lt MSISDN1_string gt lt MSISDN1 gt lt MSISDN1_type gt lt CR gt lt LF gt MSISDN supported DENN lt MSISDN2_string gt lt MSISDN2 gt lt MSISDN2_type gt lt CR gt lt LF gt OK CNUM CNUM lt phone_number gt CNUM OK MSISDN not supported The following table shows the CNUM parameters lt Parameter gt Description lt MSISDN type gt Phone number type 129 Use for local call 145 Use for international access code 128 Unknown Example AT CNUM CNUM VoiceMail 13812345678 129 OK H330 Module AT Command User Manual Page 22 of 304 Bs FIBOCOM 3 10 CLAC List of All Available AT Commands This command prints out all AT Commands supported by the H330 Command Syntax Response Action Remarks Execute CLAC List of available AT commands The Execute command displays a list of all the AT commands supported by the H330 H330 M
59. address 4 octets long in dotted decimal notation Each octet of IP address has valid value range of 0 to 255 lt SentMessages gt Specifies a total number of sent Echo Request messages lt ReceivedMessages gt Specifies a total number of received Echo Reply messages corresponding to Echo Request messages lt AvarageRTT gt Specifies average Round Trip Time RTT for this ping request This value will be reported if and only if lt ReceivedMessages gt value is greater than zero Calculation of this value comprises of accumulating all RTT values and dividing total accumulated RTT by lt ReceivedMessages gt value Only an integral part of a result will be reported and any digits of a fraction part will be truncated Example AT MIPCALL 1 internet OK MIPCALL 10 170 4 111 Ping host www sohu com 3 times with lt TTL gt 255 All other parameters are default AT MPING 1 www sohu com 3 255 OK H330 Module AT Command User Manual Page 269 of 304 Bs FIBOCOM ICMP Echo Reply message received RTT is 522 ms MPING 121 14 0 17 0 0 522 MPINGSTAT 1 MPINGSTAT 3 Flow Control OFF No corresponding reply within timeout MPINGSTAT 4 Flow Control ON a new Echo Request message is sent immediately MPING 121 14 0 17 0 0 638 Ping request execution is completed Statistics displayed to terminal Three Echo Request messages were sent and two Echo Reply messages were received Avera
60. call type will be returned For lt fac gt SC SIM Card PIN setting and for lt fac gt FD SIM Fixed Dialing memory setting the lt class gt is irrelevant For more information about lt class gt refer to the following table shows the CLCK parameters For SC the lt passwd gt is SIM PIN For FD the lt passwd gt is SIM PIN2 H330 Module AT Command User Manual Page 149 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set CLCK lt fac gt For lt fac gt where lt class gt is The Set command lt mode gt lt pas irrelevant SC FD performs the specified swd gt lt classx CLCK lt fac gt 2 lt mode gt action on the gt specified lt fac gt CLCK lt status gt For lt fac gt with several supported lt class gt es CLCK lt fac gt 2 CLCK lt status gt lt class1 gt lt CR gt lt LF gt CLCK lt status gt lt class2 gt OK Read CLCK ERROR Test CLCK CLCK list of supported lt fac gt s The Test command returns the list of supported facilities The following table shows the CLCK parameters lt Parameter gt Description lt fac gt Please see lt fac gt Table in CPWD command String type 4 8 character password Shall be the same as password lt passwd gt specified for the facility with command Change Password CPWD lt mode gt 0 Unlock 1 Lock 2 Query status lt passwd gt does not apply Note
61. following table shows the D 99 parameters lt Parameter gt Description lt GPRS_SC gt Digit string value 99 which identifies a request to use GPRS GPRS Service Code called_addres s gt String that identifies the called party in the address space applicable to the PDP For communications software that does not support arbitrary characters in the dial string a numeric equivalent may be used Also the comma character may be used as a substitute for the period character For PDP type OSP IHOSS the following syntax may be used for lt called_address gt lt host gt lt port gt lt port gt and defined in lt protocol gt where lt host gt lt protocol gt are CGDCONT Define PDP Context For communications software that does not support arbitrary characters in the dial string anumeric value equivalent to the hostname may be used However this should be avoided if at all possible lt L2P gt String variable which indicates the layer 2 protocol to be used For communications software that does not support arbitrary characters in the dial string the following numeric equivalents are used 0 NULL 1 PPP 2 PAD 3 X25 9 yyyy M xxxx H330 Module AT Command User Manual Page 218 of 304 Bs FIBOCOM containing digits 0 9 only Other values are reserved and result in an ERROR response to the Set command Note V 250 and certain communications softw
62. gt CME ERROR lt err gt Read AT CBAND CBAND lt band_1 gt lt band_2 gt lt band_3 gt lt band_4 gt J OK Test AT CBAND CBAND list of supported bands OK The following table shows the CBAND parameters lt Parameter gt Description lt band_1 gt or 0 Automatic band selection entering every time band aso possible display improbable Shand 30 850 Selection of 850 MHz band lt band_4 gt 900 Selection of 900 MHz band 1800 Selection of 1800 MHz band 1900 Selection of 1900 MHz band Note This command only for 2G network Example AT CBAND CBAND 900 1800 OK AT CBAND CBAND 0 900 1800 OK AT CBAND 900 OK AT CBAND CBAND 900 H330 Module AT Command User Manual Page 164 of 304 Bs FIBOCOM OK 9 1 8 CUBAND Change 3G Radio Band This command allows the automatically selected band switch to the bands in the following list at most four bands UMTS_BAND_ 2100 MHz UMTS_BAND_II 1900 MHz UMTS_BAND_V 850 MHz UMTS_BAND_VIII 900 MHz Command Syntax Response Action Set AT CUBAND lt band OK _1 gt L lt band_2 gt lt b a and_3 gt lt band_4 gt ll CME ERROR lt err gt Read AT CUBAND CUBAND lt band_1 gt lt band_2 gt lt band_3 gt lt band_4 gt OK Test AT CUBAND CUBAND list of supported bands OK The following table shows the CUBAND parameters lt Para
63. gt lt CR gt lt LF gt OK Test AT MSDNS MSDNS List of supported lt Socket_id gt s lt IP gt lt IP gt OK The following table shows the MSDNS parameters lt Parameter gt Description lt Socket_ID gt lt Primary_DNS_server_IP gt lt Se condary_DNS_server_IP gt A unique number that identifies a connection provided by the terminal application 0 Invalid socket number 1 2 3 4 Valid socket number 5 Valid socket number dedicated to MPING IP of the destination site in the format AAA BBB CCC DDD The range of each octant is 0 255 The value can be written in 1 2 or 3 digits Example AT MSDNS MSDNS 1 5 lt IP gt lt IP gt OK AT MSDNS read when MIPCALL is disconnected MSDNS 1 0 0 0 0 0 0 0 0 MSDNS 2 0 0 0 0 0 0 0 0 MSDNS 3 0 0 0 0 0 0 0 0 MSDNS 4 0 0 0 0 0 0 0 0 MSDNS 5 0 0 0 0 0 0 0 0 OK AT MSDNS 2 212 150 49 10 206 49 94 234 set socket 2 prim amp sec DNS OK AT MSDNS 4 62 120 55 10 OK set socket 4 prim DNS only AT MSDNS 5 212 150 49 10 206 49 94 234 set socket 5 prim amp sec DNS H330 Module AT Command User Manual Page 271 of 304 Bs FIBOCOM OK AT MSDNS read when MIPCALL is disconnected MSDNS 1 0 0 0 0 0 0 0 0 MSDNS 2 212 150 49 10 206 49 94 234 MSDNS 3 0 0 0 0 0 0 0 0 MSDNS 4 62 120 55 10 0 0 0 0 MSDNS 5 212 150 49 10 206 49 94 2
64. gt lt CR gt lt LF activation states for all the defined PDP gt contexts CGACT lt cid gt lt state gt lt CR gt lt LF gt CGACT lt cid gt lt state gt OK H330 Module AT Command User Manual Page 219 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CGACT CGACT list of supported lt state gt s OK The Test command requests information on the supported PDP context activation states The following table shows the CGACT parameters lt Parameter gt Description lt state gt Indicates the activation state of the context 0 Non active 1 Active lt cid gt 1 10 Anumeric parameter that specifies a particular PDP context definition Example AT CGACT CGACT 0 1 OK AT CGACT OK AT CGACT 1 ERROR GPRS network not present Note In some GPRS networks CGACT is not supported the ATD 99 command can be used to establish a connection Activating a context can take up to 150 seconds Deactivating a context can take up to 40 seconds When aborting a CGACT Set command the context is closed This can take up to 40 seconds H330 Module AT Command User Manual Page 220 of 304 Bs FIBOCOM 13 2 8 CGPADDR GPRS ADDResses This command reads the allocated PDP addresses for the specified context identifiers Command Syntax Response Action Remarks Set AT CGPADDR I lt cid gt CGP
65. in l text mode result codes CMS ERROR lt err gt Read AT CSDH CSDH lt show gt The read command returns the current OK lt show gt parameter value Test AT CSDH CSDH list of supported lt show gt s OK The following table shows the CSDH parameters lt Parameter gt Description lt show gt 0 Means do not show header values defined in commands CSCA and CSMP lt sca gt lt tosca gt lt fo gt lt vp gt lt pid gt and lt dcs gt nor lt length gt lt toda gt or lt tooa gt in CMT CMGL CMGR result codes for SMS DELIVERs and SMS SUBMITs in text mode for SMS COMMANDs in CMGR result code do not show lt pid gt lt mn gt lt da gt lt toda gt lt length gt or lt cdata gt default 1 Means show the values in result codes Example AT CSDH CSDH 0 1 OK AT CSDH CSDH 0 OK AT CMGR 160 SMS SUBMIT CMGR STO UNSENT 0544565034 ABC OK AT CSDH 1 OK AT CMGR 160 CMGR STO UNSENT 0544565034 81 29 0 0 04 11 04 09 48 36 08 97254120032 145 3 H330 Module AT Command User Manual Page 114 of 304 Bs FIBOCOM ABC OK 7 1 7 CNMI New Message Indications to Terminal This command handles enabling of unsolicited notifications to the terminal when an SMS is received by the H330 After sending an unsolicited response to the TE the H330 will expect a CNMA new message acknowledgement from the TE within a predefined timeout of 15 seco
66. in a subsequent unsolicited CUSD result code Command Syntax Response Action Remarks Set AT CUSD OK The Set command lt n gt L lt str or enables disables the display of gt lt dcs gt l the unsolicited result code CME ERROR lt err gt Unsolicited 4 CUSD The USSD response from the Report lt m gt lt str gt lt dsc gt HEIWane Read CUSD CUSD lt n gt The Read command displays the OK current value of lt n gt Test CUSD CUSD list of The Test command displays the supported lt n gt s supported values of lt n gt OK The following table shows the CUSD parameters lt Parameter gt Description lt n gt 0 Disable the result code presentation in the TA 1 Enable the result code presentation in the TA 2 Cancel session not applicable to read command response lt str gt String type USSD string when lt str gt parameter is not given network is not interrogated If lt dcs gt indicates that GSM 03 38 default alphabet is used e If TE character set other than HEX refer command Select TE Character Set CSCS ME TA converts GSM alphabet into current TE character set according to rules of GSM 07 05 Annex A e If TE character set is HEX ME TA converts each 7 bit character of GSM alphabet into two IRA character long hexadecimal number e g character GSM 23 is presented as 17 IRA49 and 55 If lt dcs gt indicates that 8 bit data coding scheme is
67. is lt Filter gt dependent In case the command output should be filtered to include just cells of a specific GSM band one or more the filter parameter should be set accordingly The filtering will apply to the neighbor s cells only the serving cell info will always be returned Using the set command without a parameter will return output according to the currently set lt Filter gt value H330 Module AT Command User Manual Page 170 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set AT MCl lt F OK This command will return OK only ilter gt lt ena The neighbor cell information will Execute or ble_TA gt return back with MCI format few CME ERROR lt err gt senconds later or AT MCI Read AT MCI MCI lt Filter gt The Read command returns the lt enable_TA gt current set lt Filter gt and OK lt enable_TA gt values Test AT MCl MCI List of The Test command returns the supported lt Filter gt s ranges of lt Filter gt s supported Range of supported values and lt enable TA gt s lt enable TA gt supported values OK The following table shows the MCI parameters lt Parameter gt Description lt Filter gt The requested GSM band s ARFCNs This is an integer which can be a combination of all 1 15 1 GSM 850 2 GSM 900 4 GSM 1800 8 GSM 1900 The default value is 15 lt enable TA gt This parameter defines whether lt TA gt will be repor
68. is de activated when the PDP context is off H330 Module AT Command User Manual Page 178 of 304 Bs FIBOCOM In Local Link mode the DCD line indicates the Local Link data status When AT amp C is set to 0 the DCD signal is always ON When AT amp C is set to 1 the DCD is activated in online mode When AT amp C is set to 2 the DCD is activated only when the PDP context is achieved temporary IP address is received Note If amp C is set to 2 when a CSD call is set DCD will always remain OFF Command Syntax Response Action Set AT amp C lt param gt OK Read AT amp C amp C lt param gt Test AT amp C amp C list of supported lt param gt s The following table shows the amp C parameters lt Parameter gt Description lt param gt DCD signal ON 0 DCD is forced ON at all times 1 DCD is set to ON when a ACSD carrier is detected b AGPRS external session is being established H330 enters PPP mode TE is about to send an LCP configure request to H330 GPRS connection is not yet established DCD is set to OFF when a No CSD carrier is detected b H330 has lost its GPRS connection with the network PDP context was deactivated and the IP address is cancelled 2 DCD is set to ON when H330 establishes a GPRS connection with the network PDP context is activated and the IP address is received from the network DCD is set to OFF when H330 has lost its GPRS connection with the network
69. lt Parameter gt Description lt socket_ID gt 1 2 3 4 Number of valid socket lt status gt 0 Send data to socket buffer OK 1 MIPXOFF received before send failed lt FreeSize gt Free space in current buffer Free size is calculated from the 2048 0 lt Free Size lt 2048 lt Data gt User data string is sent encoded with 0 F hexadecimal digits String ends with a lt CR gt H330 Module AT Command User Manual Page 254 of 304 Bs FIBOCOM Example Socket 4 was not opened using MIPOPEN AT command AT MIPSEND 4 4444 ERROR AT MIPSEND 1 4444 MIPSEND 1 2046 OK AT MIPSEND ERROR AT MIPSEND MIPSEND 1 2048 MIPSEND 2 2048 OK 2048 2 chars DD 2046 14 6 2 Send Data at HEX Mode Base on the basic mode H330 achieve the TCP IP stack by AT command In addition to the basic Mode the H330 supports TCP IP Stack Hex Mode The data will be sent in HEX when we use MIPSEND command Sockets 1 and 2 were opened using MIPOPEN AT command There are two methods send data at unfixed length and send data at fixed length Send data at unfixed length data end with Ctrl Z Ctrl Z character 0x1A can not be send at this method Command Syntax Response Action Remarks Set MIPSEND lt S MIPPUSH After command received ocket_ID gt lt Socket_ID gt lt Status gt lt pushed H330 will respond data length gt MIPSEND lt Socket_ID gt lt Status gt lt FreeSize g
70. lt dcs gt One octet of Data Coding Scheme indicates the data coding scheme of the DATA and may indicate a message class Note For DCS expanded information see section DCS handling default alphabet 00xx00xx 111 100xx 1 101xxxx 8 bit data OOxx01xx 111101xx UCS2 00xx10xx 111 0xxxx reserved 00xx11xx 0100xxxx 1011xxxx The default value at power up is 0 Default alphabet H330 Module AT Command User Manual Page 112 of 304 Bs FIBOCOM The following table shows the VP format lt Parameter gt Description 0 to 143 TP VP 1 x 5 minutes i e 5 minutes intervals up to 12 hours 144 to 167 12 hours TP VP 143 x 30 minutes 168 to 196 TP VP 166 x 1 day 197 to 255 TP VP 192 x 1 week Example AT CSMP CSMP 17 167 0 0 default values for SMS SUBMIT OK AT CSMP 1 256 0 0 CMS ERROR numeric parameter out of bounds AT CSMP OK AT CSDH 1 OK AT CMGF 1 OK AT CMGW 15820447141 gt ABC Z CMGW 6 OK AT CMGR 6 CMGR STO UNSENT 15820447141 129 17 0 0 167 8613800755500 145 3 ABC OK H330 Module AT Command User Manual Page 113 of 304 Bs FIBOCOM 7 1 6 CSDH Show Text Mode Parameters This command controls whether detailed header information is shown in text mode result codes Command Syntax Response Action Set CSDH lt sho OK The set command controls whether w gt Sr detailed header information is shown
71. of different duration from that set by the VTD command 1 10 100mS to 1S adjustable Note The duration defined by VTS is specific to the DTMF string in this command only It does not erase the duration defined by the VTD command and is erased when the H330 is powered down lf lt duration gt is not defined the VTD value is used 11 2 9 VTA Set play DTMF type This command enable disable play DTMF tone at local side when send DTMF to the network by VTS Command Syntax Response Action Remarks Set VTA lt para gt OK or ERROR Enable Disable play DTMF at local side Read VTA VTA lt para gt OK or ERROR Query status Test VTA VTA lt para gt OK or ERROR H330 Module AT Command User Manual Page 198 of 304 Bs FIBOCOM The following table shows the VTA parameters lt Parameter gt Description lt para gt 0 Disable play DTMF tone at local side 1 Enable play DTMF tone at local side Default value Example AT VTA VTA 1 OK AT VTA VTA 0 1 OK 11 2 10 MAPATH Audio Path This command sets requests the active input accessory and the output accessory for each feature On power up the default path mic speaker and alert speaker are restored Command Syntax Response Action Remarks Set MAPATH OK The Set command sets the audio path mode The mode indicates which I O accesso
72. power cycle H330 auto baudrate detect supports the next baudrates 1200 2400 4800 9600 19200 38400 57600 115200 230400 The parameter can t be saved after power up Command Syntax Response Action Set CBAUD lt n gt OK CBAUD lt rate gt or CME ERROR lt err gt Read CBAUD CBAUD lt rate gt OK Test CBAUD CBAUD list of supported lt n gt s list of supported lt rate gt s OK The following table shows the CBAUD parameters lt Parameter gt Description lt n gt lt rate gt 0 Auto baud rate 1 Auto baud rate 2 300 3 1200 4 2400 H330 Module AT Command User Manual Page 174 of 304 Bs FIBOCOM 5 4800 6 9600 7 19200 8 38400 9 Auto baud rate 10 57600 11 115200 12 230400 13 460800 14 921600 The default value is 115200 10 1 2 IPR Local Terminal Serial Port Rate This command is responsible for setting and saving the request baud rate The numeric extended format parameter specifies the data rate at which the H330 accepts Specifying a value of 9 disables the function and allows automatically rate detectable only The specified rate takes effect following the issuing of any result code s associated with the current command line The specified lt rate gt value is the rate in bits per second at which the terminal H330 interface operates for example 19200 or 115200 The rates supported by H3
73. response also provides a gt lt ReceivedMessages statistics summary of ping request when ping gt L lt AverageRTT gt request execution is completed H330 Module AT Command User Manual Page 268 of 304 Bs FIBOCOM The following table shows the MPINGSTAT unsolicited response parameters lt Parameter gt Description lt status gt Specifies a status of ping request execution Defined values 0 The unsolicited response with this lt status gt will be sent to DTE upon completion of ping request If ping request was aborted or socket connection was terminated for any reason this unsolicited response will not be reported to DTE 1 The unsolicited response with this lt status gt will be sent to DTE if no ICMP reply message was received within timeout 2 The unsolicited response with this lt status gt will be sent to DTE if socket connection was terminated for any reason This status essentially means that ping request execution was aborted 3 Flow Control OFF The unsolicited response with this lt status gt will be sent to DTE if phone doesn t have enough memory to process sending an Echo Request message 4 Flow Control ON The unsolicited response with this lt status gt will be sent to DTE if phone has enough memory to send an Echo Request message after flow control was OFF lt Destination_IP gt Specifies the target machine computer for ping request which is identified by IP
74. sub address octet in integer format lt class gt The sum of integers each representing a class of information Please see class table in CCWA command The default value is 7 lt time gt 1 30 The number of seconds to wait before calls are forwarded when no reply is enabled or queried The default value is 20 Note The parameter must be a multiple of 5 for example 5 10 15 and so on lt status gt 0 Not active 1 Active Note A forward to phone lt number gt and the optional fields lt type gt lt subaddr gt and lt satype gt are tied to a lt reason gt and a lt class gt This means that there can be a different lt number gt for the same lt reason gt because of a different lt class gt When registering without mentioning a lt class gt lt class gt 7 is selected A lt number gt field is mandatory when registering lt mode gt 3 and it is irrelevant ignored in all other lt mode gt s H330 Module AT Command User Manual Page 62 of 304 Bs FIBOCOM Example AT CCFC CCFC 0 1 2 3 4 5 OK AT CCFC 0 3 01256316830 129 1 OK AT CCFC 1 3 0545658278 129 1 Register UC forward to of all classes OK AT CCFC 1 1 Activate UC forward to of all classes OK AT CCFC 1 2 nterrogate reason not reachable of all classes CCFC 1 1 97254151200 145 CCFC 0 2 0 CCFC 0 4 0 OK For lt reason gt 3 forward only voice calls is activated AT CCFC 4 2
75. subaddress using the format specified by lt satype gt lt satype gt Sets the address octet type in integer format refer to GSM 04 08 subclause 10 5 4 8 Example AT COLP 0 OK AT COLP 2 CME ERROR operation not supported H330 Module AT Command User Manual Page 92 of 304 Bs FIBOCOM 6 Phone Book and Clock 6 1 Directory Access Commands Phone Book This set of commands enables read write access to the phone book contained within the H330 including both the numeric and the alpha information contained in the location The presentation is according to GSM 07 07 In some cases it may be possible to use these commands to access the dialed and received call stacks However as these phone books cannot be edited the CPBW command does not work on them 6 1 1 CPBS Select Phone Book Memory This command handles the selection of the memory to be used for reading and writing entries in the H330 s phone books memory Command Syntax Response Action Remarks Set AT CPBS lt st OK The Set command selects the orage gt L lt pin Be phone book memory storage 2 gt which is to be used by other ae CME ERROR lt err gt phone book commands lt pin2 gt is optional while lt storage gt FD only Read CPBS CPBS lt storage gt The Read command returns the L lt used gt lt tot currently selected phone book memory number of used entries al gt and total number of entries in the OK phone book me
76. supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s The following table shows the CGEQREQ parameters lt Parameter gt Description lt cid gt Anumeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt Anumeric parameter that indicates the type of application for which the UMTS bearer service is onfirmat 0 conversational 1 streaming 2 interactive 3 background subscribed value If the Traffic class is specified as conversational or streaming then the Guaranteed and Maximum bitrate parameters should also be provided Other values are reserved lt Maximum bitrate UL gt A numeric parameter that indicates the maximum number of kbits s delivered to UMTS up link traffic at a SAP As an example a bitrate of 32 kbit s would be specified as 32 e g AT CGEQREQ 32 This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Maximum bitrate DL gt Anumeric parameter that indicates the maximum number of kbits s delive
77. the network Command Syntax Response Action Remarks Set COLP OK The Set command enables disables the lt n gt CME ERROR display of the COL at the TE on the H330 It Sans has no effect on the execution of the COLR supplementary service on the network The value set by this command is not retained after a power cycle Read COLP COLP lt n gt lt m gt The Read command displays the status of OK lt n gt It also initiates a query of the COLP service provision status and displays lt m gt Test COLP COLP list of The Test command displays the supported values of lt n gt supported lt n gt s OK The following table shows the COLP parameters lt Parameter gt Description lt n gt Sets displays the result code presentation status of the H330 0 Disable default 1 Enable lt m gt Displays the subscriber s COLP service status in the network 0 COLP not provisioned 1 COLP provisioned 2 Unknown for example no network and so on lt number gt Sets the phone number using the format specified by lt type gt H330 Module AT Command User Manual Page 91 of 304 Bs FIBOCOM lt Parameter gt Description lt type gt Sets the address octet type in integer format refer to GSM 04 08 subclause10 5 4 7 129 Unknown 145 International used when dialing string includes international access code character lt subaddr gt Sets the
78. the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds If the parameter is set to 0 the subscribed value will be requested refer 3GPP TS 24 008 subclause 10 5 6 5 lt Traffic handling priority gt a numeric parameter 1 2 3 that specifies the relative importance for handling ofall SDUs belonging to the UMTS bearer compared to the SDUs of other bearers If the parameter is set to 0 thesubscribed value will be requested refer 3GPP TS 24 008 subclause 10 5 6 5 lt Source Statistics Descriptor gt lt Signalling Indication gt Supported in R7 P S a numeric parameter that specifies characteristics of the source of the submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 0 Characteristics of SDUs is unknown default value 1 Characteristics of SDUs corresponds to a speech source Other values are reserved Supported inR7PS anumeric parameter used to indicate confirmat content of submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as interactive refer 3GPP TS 24 008 subclause 10 5 6 5 0 PDP context is not optimized for confirmat default value 1 PDP context is optimized for confirmat lt PDP_type gt see CGDCONT and CGDSCONT commands Example AT CGEQREQ
79. this command the program will start data connection process download the speicifed file data from the server and stay in this command mode all the time When the data downloading is completed or the buffer is full in the module it will exit from this mode In this command mode if only response to FTPRECV command and other non FTP command it only shows ERROR when executs other FTP command After the module receives the data it doesn t transfer to the serial port directly instead it stores the data in the cache If the user wants to get the downloaded data please use FIPRECV command When the buffer is full in the module it will exit from the command module after get all data by FTPRECY it will enter this mode again and fill buffer then exit from FTPGET module the cycle repeats until the file read successfully After return OK it still cannot get the data as it need a procedure to establish the connection and download to buffer AT FTPRECV can be used for reading data after FTPGET 2 comes up can first use H330 Module AT Command User Manual Page 289 of 304 Bs FIBOCOM AT FTPRECV to request the data size of current buffer So far the size of buffer is 30k Command Syntax Response Action Remarks Set FTPGET lt filenam OK e gt lt viewmode gt cr lt file_name gt is a complete qualified path lt offset gt and file name on the server site lt Offset gt ERROR F f is the file offset address a
80. 0 to lt T2 gt lt T3 gt L lt k gt open the MUX stack with various parameters This command works only in PREMUX state Read CMUX CMUX lt mode gt The Read command lt subset gt displays the current lt port_speed gt lt N1 gt lt T1 gt Mode and settings lt N2 gt This command works only in MUX state lt T2 gt lt T3 gt lt K gt CME ERROR lt err gt Test CMUX CMUX list of supported The Test Command lt mode gt s list of displays a list of supported lt subset gt s list of supported modes supported and parameters This lt port_speed gt s list command works in ofsupported lt N1 gt s listof both PREMUX and supported lt T1 gt s list MUX states ofsupported lt N2 gt s list of supported lt T2 gt s list ofsupported lt T3 gt s list of supported lt k gt s H330 Module AT Command User Manual Page 207 of 304 Bs FIBOCOM The following table shows the CMUX parameters lt Parameter gt Description lt mode gt MUX mode O Basic lt subset gt Defines how the MUX control channel is set up The virtual channel is set up according to this setting 0 UlH frames used only lt port_speed gt 1 9600 bit sec 2 19200 bit sec 3 38400 bit sec 4 57600 bit sec 5 115200 bit sec default 6 230400 bit sec 7 1 Mbit s lt N1 gt lt T1 gt Maximum frame size 1 1509 The default value is 31 in Basic mode Acknowledgement timer in unit
81. 0c9179524286502900040441424344 No VP in PDU message H330 Module AT Command User Manual Page 135 of 304 Bs FIBOCOM CMGW 131 OK AT CMGR 131 CMGR 2 17 079179521201009501000C91 79524286502900040441424344 OK AT CMGW 14 gt 07917952140230F212000000000c9179524286502900 SMS Command CMGW 132 OK AT CMGR 132 CMGR 2 14 07917952140230F212000000000C91 79524286502900 OK AT CMGF 1 OK AT CMGR 132 CMGR STO UNSENT 18 0 0 0 972524680592 145 0 OK 7 1 18 CMGD Delete Message This command handles deletion of a single message from memory location lt index gt or multiple messages according to lt delflag gt If the optional parameter lt delflag gt is entered and is greater than 0 the lt index gt parameter is practically ignored If deletion fails result code CMS ERROR lt err gt is returned Note The deletion of multiple commands is a time consuming process that may require more than 60 seconds to complete Command Syntax Response Action Remarks Set CMGD lt inde OK x gt lt delflag gt or CMS ERROR lt err gt Read The Read command for CMGD is not defined by ETSI and therefore is not supported by the H330 The H330 returns an error Test CMGD CMGD list of The Test command displays the supported valid lt index gt s list values of lt index gt it list the index where of valid lt deflag gt s have stored the SMS H330 Module AT Command
82. 12 MATONE Start or stop the tone play cessssescsssccsseccsseecnsecsseesseecsseecsseecsseccsneecsseccsseessseesees 202 11 2 13 MMIGG Microphone Gain Value eessssescssescsssecssescsseecsseecssecssseesssecsuecesseecsueeesueecsneceaseessseesuseesies 205 12 Multiplexer Feature cessssscssscssescsseccsseecsssscssescsssccsseccsssccsseccsseesssesssseesueesueecsuccessescsueeesseecsseessseessseessseesuseesueeesneeesueeess 207 12 1 CMUX MUX Startup COMMANA sssscsescsseecssccsseccsseccsseecssecsuseessecsuecesscesueeesueecsnecesseccsneeesseccneeesuseesees 207 MS GRR E A E TA T AA N E E S S 209 13 1 GPRS Functionality s sssssssssssssssssssssssssssssssesesessusssseeeeeesessussseeeseeseesussssssetteeesesssssssnsttneeeeesssssnsstttreesesssssssseeettte 209 13 2 GPRS EOTLALAAT IALO CA 209 13 2 1 CGCLASS GPRS Mobile Station ClaSS ssssssssssssssssssssssssssesessssssssseseseressssssssseseseeeesensssssesereeeesssss 209 13 2 2 CGDCONT Define PDP Conte xt eesssssssccsssescsssssecssssessnsecssnsseesssecessnsecssusecssnseeessnecessuseessuseessnseess 210 13 2 3 CGQMIN Quality of Service Profile Min Acceptable cssscsssssccssescesssesesssecessneecesneeessneeees 213 13 2 4 CGQREQ Quality of Service Profile Requested sessssssccsssecccsseeccssccesssecessseeecsncessneessneeesees 214 13 2 5 CGATT GPRS Attach or Detach ccssssssscsseecsssecsseecsseccsssccsseccsssessseessseesusecsueecsueessneccsseecsseesnseesiee 216 13
83. 2 OK AT CMSS 7 054565132 129 CMSS 13 OK Note Any character sent by TE to H330 before H330 has reported a result of AT CMSS operation will abort AT CMSS command execution However if SMS was already sent to network and sending operation was successful the result of operation CMSS lt mr gt will be reported by H330 If after aborting AT CMSS command execution and before result of operation was reported by H330 a second AT CMSS command is executed then the result of the second AT CMSS operation only will be reported by H330 H330 Module AT Command User Manual Page 133 of 304 Bs FIBOCOM 7 1 17 CMGW Write Message to Memory This command is used to write and save a message to lt mem2 gt The message is saved in memory and the message index is displayed to the user By default messages are saved with the status of STO UNSENT but status STO SENT can be applied using the lt stat gt parameter In TEXT mode the header parameters will be set according to CSMP settings Command Syntax Response Action Remarks Set If text mode CMGF 1 CMGW lt index gt The Set command writes a message and stores it CMGW lt da gt lt toda gt lt stat gt lt C Or R gt text is entered lt ctrl Z ESC gt 4CMS ERROR lt err gt if PDU mode CMGF 0 CMGW lt length gt lt stat gt lt CR gt PDU is given lt ctrl Z ESC gt Example AT CMGF 1 OK AT CMGW 5124335432
84. 2 11 acceptable CGEQMIN 3G Quality of Service Profile Minimum This command allows the TE to specify a minimum acceptable profile which is checked by the MT against thenegotiated profile returned in the Activate Modify PDP Context Accept message Command Syntax Response Action Remarks Set AT CGEQMIN lt ci OK Set command d gt lt Traffic class gt Or specifies a profile L lt Maximum for the context Siteiedi CME ERROR lt error gt identified by the lt Maximum bitrate HOGA COMTEX DL gt lt Guaranteed enan parameter lt cid gt bitrate UL gt The specified lt Guaranteed profile will be bitrate DL gt stored in the MT lt Delivery and checked order gt lt Maximum against the SDU size gt lt SDU negotiated profile error ratio gt only at activation f or MS initiated lt Residual bit error modification of ratio gt lt Delivery of the related erroneous CONEXE SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt L lt Signalling indication gt J Read AT CGEQMIN CGEQMIN lt cid gt lt Traffic The read class gt lt Maximum bitrate UL gt lt Maximum command returns bitrate DL gt lt Guaranteed bitrate the current UL gt lt Guaranteed bitrate DL gt lt Delivery settings for each order gt lt Maximum SDU size gt lt SDU error defined context ratio gt lt Residual bit error ratio gt lt Delive
85. 2 6 D 99 Request GPRS Service D on eessssessssesesssecssecesssccsseccsseecssecsssecssseesuscesuccsuecesneecsneccsseessseessseesiee 217 13 2 7 CGACT PDP Context Activate or Deactivate oe sssessssecsscnsesseesssecssscsssesssesssenseenseansesseeesees 219 13 2 8 CGPADDR GPRS ADDRESSES ssssccssssscessseccsssecesssececsusecesucessuscecsssecessusceesuseessnseessasecessueeeesueeessneeees 221 13 2 9 CGANS Manual response to a network request for PDP context activation 222 13 2 10 CGAUTO Automatic Response to a Network Request for PDP Context Activation 223 13 2 11 CGEQMIN 3G Quality of Service Profile Minimum acceptable sssecccsscccsseeesneees 225 13 2 12 CGEQREQ 3G Quality of Service Profile Requested ou essssssscsssescesssecessseeccsseecssueeeesneeees 229 13 2 13 CGEQNEG G Quality of Service Profile Negotiated essssssccsseeccssseccsssecccsseecssneeeesneeess 234 13 2 14 CGCMOD PDP Context Modify ssssssccsssscccssseccssseecssseessssescssussesssseecssscesssneeessusecesnsecessneecesneees 236 13 2 15 CGDATA gt Enter Data State cssssssssssssesssessscsssessscssscssscssscssscssscsssessscasscsssesssensseassenssenssenees 237 13 2 16 CGDSCONT Define Secondary PDP Conte xt sssssccsssssccssecesssesccsnsscsssssccsssseecsseeessneeeesneeessee 238 13 2 17 CGEREP Packet Domain Event Reporting sessssssssscsssecsstecssesesseecssecessescsneccsseessseesnseesses 240 13 2 18 CGTFT Traffic Flow Ter
86. 255 READ BINARY lt P1 gt Rec No 0 255 lt P2 gt Mode 02 next record 03 previous record 04 absolute mode current mode the record number is given in P1 with H330 Module AT Command User Manual Page 34 of 304 Bs FIBOCOM P1 00 denoting the current record lt P3 gt Length 0 255 GET RESPONSE lt P1 gt 00 lt P2 gt 00 lt P3 gt Length 0 255 UPDATE BINARY lt P1 gt Offset high 0 255 lt P2 gt Offset low 0 255 lt P3 gt Length 0 255 UPDATE RECORD lt P1 gt Rec No 0 255 lt P2 gt Mode 02 next record 03 previous record 04 absolute mode current mode the record number is given in P1 with P1 00 denoting the current record lt P3 gt Length 0 255 STATUS lt P1 gt 00 lt P2 gt 00 lt P3 gt Length 0 255 lt data gt Information which shall be written to the SIM hexadecimal character format Man datory for UPDATE BINARY and UPDATE RECORD lt pathid gt String type contains the path of an elementary file on the SIM USIM in hexadecimal format as defined in ETSI TS 102 221 60 e g 7F205F70 in SIM and USIM case lt sw1 gt Integer character format Information from the SIM about the execution of Agios the actual command These parameters are delivered to the TE in both cases on successful or failed execution of the command lt sw1 gt lt sw2 gt integer type containing
87. 3 Single call active 4 Multi party call active 5 Single call held 6 Multi party call held 7 Dual call fully connected active call and held call 8 Dual multi party call active 9 Dual multi party call held 10 Single active call plus call waiting 11 Multi party call active plus call waiting 12 Single call held plus call waiting 13 Multi party call held plus call waiting 14 Dual calls plus call waiting 15 Dual multi party calls active plus call waiting 16 Dual multi party calls held plus call waiting 17 Call control busy 64 Calling 68 No Service 69 No Redial 72 Security Fail Example AT MCST MCST lt idle gt AT MCST 1 H330 Module AT Command User Manual Page 76 of 304 Bs FIBOCOM OK atd035684423 MCST 17 OK MCST 17 OK MCST 3 MCST 17 NO CARRIER MCST 1 5 5 Call Advice of Charge Commands This set of commands enables GSM operators to offer Advice of Charge AoC services that calculate call charges These charges are expressed in terms of home units 5 5 1 CAOC Advice of Charge This command displays information about the cost of calls If supported this command also activates deactivates unsolicited event reporting of the CCM Current Call Meter information The unsolicited report CCCM lt ccm gt is sent when the CCM value changes but not more than once every 10 seconds Note The CCM value depends on the network properti
88. 30 Module AT Command User Manual Page 139 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set CSCB lt If mode 0 and lt mids gt is not The Set command sets mode gt lt specified then no channels are the cell broadcast mids gt L lt d accepted and the H330 message type and data css gt channel mid list is cleared coding scheme OK or CME ERROE lt err gt Read CSCB The Read command CSCB lt mode gt lt mids gt lt dcss gt displays the current MID OK and DCS settings li Test CSCB CSCB list of supported The Test command i displays the supported OK values of lt mode gt Note The Channel and DCS list is saved to the SIM card The maximum number of active channels is SIM dependent The AT CSCB set command is not available when the phone is either in Emergency Only or No Service status The following table shows the AT CSCB parameters lt Parameter gt Description lt mode gt The current broadcast message mode 0 MIDs and DCSs accepted 1 MIDs and DCSs not accepted lt mids gt Cell broadcast message identifiers 0 65534 lt dcss gt Cell broadcast message data coding schemes 0 255 Note e Acombination of discrete values or intervals can be entered for lt mids gt and lt dcss gt for example 0 1 5 320 324 922 e The default value for missing lt mode gt is 1 e The string type lists lt mids gt and lt d
89. 30 are manufacturer specific However the IPR parameter permits setting any rate supported by H330 during online operation The UART is configured to rates of 300 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600 bits per second according to the parameters of the IPR command Using AT IPR lt rate gt with a lt rate gt value other than 0 1 or 9 disables the auto baud rate detection feature The entered baud rate is stored in H330 and is restored after power up The H330 auto baudrate detect supports the next baudrates 1200 2400 4800 9600 19200 38400 57600 115200 230400 Note IPR is similar to CBAUD but has the alility to save after power down Command Syntax Response Action Set IPR lt n gt OK IPR lt rate gt or CME ERROR lt err gt Read IPR IPR lt rate gt OK Test IPR IPR list of supported lt rate gt s OK H330 Module AT Command User Manual Page 175 of 304 Bs FIBOCOM Note Read mode returns the current baud rate rather than the value that was set by Set Mode The following table shows the IPR parameters lt Parameter gt Description lt n gt lt rate gt 0 Auto baud rate 1 Auto baud rate 2 300 3 1200 4 2400 5 4800 6 9600 7 19200 8 38400 9 Auto baud rate 10 57600 11 115200 12 230400 13 Ss lt x 7 OOBVOO 14 921600 The default value is 115200
90. 330 Module AT Command User Manual Page 293 of 304 Bs FIBOCOM AT MAIDIGITAL 1 output digital signal directly OK AT MAIDIGITAL MAIDIGITAL 1 OK AT MAIDIGITAL MAIDIGITAL 0 1 OK Note e AT MAIDIGITAL set to 1 MAPATH is invalid e AT MAIDIGITAL set to 0 MAI2SY is invalid e The setting is invalid when calling 16 2 MAIZ2SY Set Digital Audio to Transmit Parameters This command is used for setting digital audio to transmit the parameters including master mode and slave mode transmission mode sampling rate and word width The setting is invalid when MADIGITAL is 0 Command Syntax Response Action Remarks Set MAI2SY lt master gt lt tran_m OK ode gt lt sample gt lt wi 0 Notice that it match with the module parameters when use external lt 0 1 gt lt 0 1 gt lt 0 1 2 3 4 gt lt 0 1 2 gt OK dth gt ERROR CODEC otherwise the external CODEC may cannot receive the audio data correctly Read MAI2SY MAI2SY lt master gt lt tran_mode gt lt sampl Read the current e gt lt width gt parameter value OK Test MAI2SY MAI2SY Parameter range H330 Module AT Command User Manual Page 294 of 304 Bs FIBOCOM The following table shows the MAI2SY parameters lt Parameter gt Description lt master gt Set data transmission to master mode or slave mode 0 module is in master mode exte
91. 34 OK 14 17 MIPODM Open a Socket UDP or TCP in Online Data Mode This command causes the H330 to initialize a new socket that waits for a connection from a remote machine or opens a common or TCP connection with a remote side according to received parameters and switch it to Online raw data transfer Data Mode and open a connection with a remote side Notes Online Data Mode allows the user to transfer raw data from terminal to Network and vice versa over a GPRS channel Currently only RS232 connection to terminal with hardware flow control is supported Each socket allocates two accumulating buffers 8192 bytes for sending and 16384 bytes for receiving When the user sends amount of data less than buffer size the data is being sent to Network after a spooling timeout 50 mS otherwise the data is being sent to Network immediately Only one socket is allowed at the same time in Online Data Mode The MIPODM command returns a MIPSTAT lt Socket_ID gt lt Error gt unsolicited event if it fails For example if it was rejected by the remote side Command Syntax Response Action Remarks Set AT MIPODM OK The Set command returns lt Socket_ID gt or lt Remote IP gt and lt Remote lt Source Port gt MIPODM lt Socket_ID gt Port gt parameters only for lt Remote IP gt lt State gt lt Remote IP gt sockets opened in Listen lt Remote Port gt lt Remote Port gt mode lt Protocol gt or MIPS
92. 56 OK AT CSCA CSCA 97212356 129 OK AT CSCA CSCA AC 129 OK AT CMGW 13 gt 0481ABCD1211640A8150224902450000A700 gt A CMGW 15 OK AT CMGR 15 CMGR 2 13 H330 Module AT Command User Manual A gt B B gt C gt D Page 110 of 304 Bs FIBOCOM 0481ABCD1211640A8150224902450000A700 OK AT CSCA SCA read as stored for current SMS CSCA AC 129 Read command remained SCA settings didn t change OK AT CSCA CSCA AC 129 OK AT CMGW gt 0011640A8150224902450000A700 CMGW 16 OK AT CMGR 16 CMGR 2 13 0481CAEDFB11640A8150224902450000A700 OK AT CMGW 13 gt 0381AB1211640A8150224902450000A700 CMGW 17 OK AT CMGR 17 CMGR 2 13 0381AB1211640A8150224902450000A700 setting didn t changed OK AT CSCA SCAis ACDEB in pdu mapped to ABC Set SCA to BA21 SCA is set correctly only for current SMS but CSCA CSCA AC 129 SCAdidn t change in storage OK 7 1 5 CSMP Set Text Mode Parameters This command is a basic command and is used to select values for additional parameters needed when SMS is sent to the network or placed in storage when TEXT mode is selected Command Syntax Response Action Remarks Set CSMP lt fo OK The set command selects values for gt L lt vp gt L lt pi be additional parameters needed when SMS is d gt lt dcs gt sent to the network or placed in storage
93. 701 incorrect security code 702 max attempts reached 1001 Unassigned unallocated number 1003 No route to destination 1006 Channel unacceptable 1008 Operator determined barring 1016 Normal call clearing 1017 User busy 1018 No user responding 1019 User alerting no answer 1021 Call rejected 1022 Number changed 1026 Non selected user clearing 1027 Destination out of order 1028 Invalid number format incomplete number 1029 Facility rejected 1030 Response to STATUS ENQUIRY 1031 Normal unspecified 1034 No circuit channel available 1038 Network out of order 1041 Temporary failure 1042 Switching equipment congestion 1043 Access information discarded 1044 requested circuit channel not available 1047 Resources unavailable unspecified 1049 Quality of service unavailable 1050 Requested facility not subscribed 1055 Incoming calls barred within the CUG 1057 Bearer capability not authorized 1058 Bearer capability not presently available 1063 Service or option not available unspecified 1065 Bearer service not implemented H330 Module AT Command User Manual Page 298 of 304 Bs FIBOCOM 1068 ACM equal to or greater than ACMmax 1069 Requested facility not implemented 1070 Only restr digital information bearer capability 1079 Service or option not implemented unspecified 1081 Invalid transactio
94. 8 subclause 10 5 4 7 string type field of maximum length lt slength gt character set as specified lt secondtex gt by command Select TE Character Set CSCS string type field of maximum length lt elength gt character set as specified lt email gt by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt lt alength gt integer type value indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of field lt email gt H330 Module AT Command User Manual Page 96 of 304 Bs FIBOCOM Example AT CPBS SM OK AT CPBR CPBR 1 250 20 14 OK At CPBR 1 OK AT CPBR 1 3 There is nothing written in entry 1 2 3 OK AT CPBR 4 CPBR 4 18888888 129 Tom OK 6 1 3 CPBF Find Phone Book Entries This execution command enables the user to search for a particular entry by name in the currently active phone book If no matching entry is found the command returns OK If multiple matches are found all are returned Command Syntax Response Action Set CPBF lt fi ndtext gt CPBR lt index1 gt lt number gt lt type gt lt text gt lt hidden gt lt group gt L lt a dnumber gt lt adtype gt lt secondtext gt lt email gt lt CR gt lt LF gt CPBR
95. ADDR The Set command returns a list lt cid gt lt cid gt lt PDP_addr gt lt CR gt lt L of PDP addresses for the F gt specified context identifiers CGPADDR lt cid gt lt PDP_addr gt OK or CME ERROR lt err Test AT CGPADDR CGPADDR list of defined The Test command returns the lt cid gt s list of defined lt cid gt s OK The following table shows the CGPADDR parameters lt Parameter gt Description lt cid gt Anumeric parameter that specifies a particular PDP context definition If no lt cid gt is specified the addresses for all defined context are returned lt PDP_address gt Astring that identifies the MT in the address space applicable to the PDP The address may be static or dynamic For a static address it will be the one assigned during the last PDP context activation that used the context definition referred to by lt cid gt lt PDP_address gt is omitted if none is available Example AT CGPADDR CGPADDR 1 2 OK AT CGPADDR 1 CGPADDR 1 0 0 0 0 OK H330 Module AT Command User Manual Page 221 of 304 Bs FIBOCOM 13 2 9 CGANS Manual response to a network request for PDP context activation This command requests the MT to respond to a network request for Packet Domain PDP context activation which has been signalled to the TE by the RING or CRING unsolicited result code Command Syntax Response Action Remarks Set AT CGANS I lt r OK
96. ALL 66 UNANSWERED_CALL_PENDING 68 USSD_CANCELED 69 PRE_EMPTION 70 OPERATION_NOT_ALLOWED 7 NO_FREE_BEARER_AVAILABLE 7 NBR_SN_EXCEEDED SN_EXC 73 NBR_USER_EXCEEDED 74 Call Control by SIM Causes NOT_ALLOWED_BY_CC 75 MODIFIED_TO_SS_BY_CC 76 MODIFIED_TO_CALL_BY_CC 7 CALL_MODIFIED_BY_CC 78 App Cause FDN_FAILURE 90 Example AT CUSD 1 00 0549598743 CUSD 0 Connecting 15 CUSD 0 Connected 15 CLCC 1 1 4 0 0 0545550099 129 RING ATA gt answer to the server when answered the server call to 0549598743 OK CLCC 1 1 0 0 0 0545550099 129 NO CARRIER H330 Module AT Command User Manual gt Call from USSD server Page 90 of 304 Bs FIBOCOM CLCC 1 1 6 0 0 0545550099 129 5 6 3 COLP Connected Line Identification Presentation This command relates to the GSM supplementary service called COLP Connected Line Identification Presentation which enables a calling subscriber to obtain the connected line identity COL of the called party after setting up a mobile originated call with the H330 For example after setting up a mobile originated call to one number that is forwarded to another number the calling party will see the number of that third party When this command is enabled and the called subscriber permits it the following intermediate result code is returned COLP lt number gt lt type gt lt subaddr gt lt satype gt Note This command is activated when COLP is supported by
97. AT Command User Manual Page 99 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CPBW CPBW list of supported lt index gt s lt nlengt h gt list of supported lt type gt s lt tlength gt lt glength gt lt alength gt lt slength gt lt elength gt This command queries the allowable command field and sizes OK The following table shows the CPBW parameters lt Parameter gt Description lt index gt Index for a given phone book entry lt number gt Phone number of a given entry lt type gt The address type of a phone number 129 Use for local call 145 Use for international access code 128 Unknown Note 128 is used to represent an email address or a mailing list In this case lt ph_type gt can be used to further differentiate between the two lt text gt Text identifier for a phone book entry according to the character set as specified by command CSCS lt nlength gt The maximum size of a phone number in digits There is a limited number of PB records that can be stored with this length The number of long PB records depends on the size of the SIM card EXT1 extension file If the extension file is full an attempt to store a new record with more than 20 digits returns an error lt tlength gt The maximum number of characters in the lt text gt entry This applies to GSM standard characters only No
98. ATS24 5 and if there are no radio and UART activities the H330 enters sleep mode in 5 seconds Command Syntax Response Action Remarks Set ATS24 lt value OK The Set command sets the amount gt of time in seconds the H330 should wait before entering Sleep mode Read ATS24 lt value gt The Read command returns the OK current value H330 Module AT Command User Manual Page 39 of 304 Bs FIBOCOM The following table shows the S24 parameters lt Parameter gt Description lt value gt Number of seconds 0 lt n lt 255 0 Disable Sleep mode gt 0 Enable Sleep mode The default value is 000 Note H330 can not enter sleep mode in 30 seconds at the beginning of power up Example ATS24 000 OK ATS24 5 OK ATS24 005 OK If there are no Radio activities Radio and Data transmission on UART the H330 will enter sleep mode in 5 seconds 4 3 Error Handling Commands 4 3 1 CMEE Report Mobile Equipment Error The Set command disables or enables the use of result code CME ERROR lt err gt as an indication of an error relating to the functionality of the H330 When enabled H330 related errors cause a CME ERROR lt err gt final result code instead of the regular ERROR final result code Usually ERROR is returned when the error is related to syntax invalid parameters or terminal functionality For all Accessory AT commands besides SMS commands the CMEE s
99. BS FIBOCOM erfect Wirele Bs FIBOCOM Confidential Material This document contains information highly confidential to Fibocom Wireless Inc Fibocom Fibocom offers this information as a service to its customers to support application and engineering efforts that use the products designed by Fibocom The information provided is based upon requirements specifically provided to Fibocom by the customers All specifications supplied herein are subject to change Disclosure of this information to other parties is prohibited without the written consent of Fibocom Copyright Copy Reproduce Distribute and or Edit of this document or part of it as well as utilization of its contents and communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by patent grant or registration of a utility model or design patent are reserved Copyright 2013 Fibocom Wireless Inc All rights reserved Trademarks Notice Be FIBOCOM The FIBOCOM Logo is registered by Fibocom Wireless Inc All other product or service names or logos are the property of their respective owners Copyright 2013 Fibocom Wireless Inc All rights reserved Revision History Version Date Remarks V1 0 0 2012 05 30 Initial Version V1 1 0 2012 06 29 Update product model name V1 1 1 2012 07 31 Update any items IPR UART2 etc Update description in chapter14 6 2 and 14 6 3
100. C lt DCE_by_DTE gt OK DTE_by_DCE on ERROR Read AT IFC IFC lt rate gt OK Test AT IFC IFC list of supported lt DCE_by_DTE gt s list of supported lt DTE_by_DCE gt s OK The following table shows lt DCE_by_DTE gt and lt DTE_by_DCE gt parameters lt Parameter gt Description lt DCE_by_DTE gt 0 None 2 Circuit 133 RTS lt DTE_by_DCE gt 0 None 2 Circuit 106 CTS Example AT IFC IFC 0 0 OK AT IFC 2 2 OK 10 1 5 amp C Circuit 109 Behavior This parameter determines how the state of the DCD line relates to the detection of the received line signal from the distant end Changing the parameters will take effect immediately in both the command and online command states The DCD line is an output line that indicates the following In Circuit Switch Data mode an active low indicates that a valid carrier data signal was detected by H330 CONNECT message is received and inactive high indicates idle The AT amp C command always puts the DCD command ON when set to 0 If the AT amp C command is set to 1 then the escape command sets the DCD signal to an inactive state and the ATO command is set to active AT amp C set to 2 sets the DCD signal OFF In GPRS mode the DCD line indicates the PDP context status PDP context active sets the DCD to active low PDP context inactive sets the DCD to inactive high DCD is activated only when the PDP context is achieved DCD
101. CPIP etcpip not active 2033 TCPIP not def4 H330 Module AT Command User Manual Page 304 of 304
102. CWA Indication When a call waiting indication is enabled by the H330 lt n gt 1 the following unsolicited indication is sent to the terminal from the H330 CCWA lt number gt lt type gt lt class gt lt alpha gt lt CLI validity gt H330 Module AT Command User Manual Page 56 of 304 Bs FIBOCOM The following table shows the CCWA parameters lt Parameter gt Description lt n gt Enables disables the call waiting indication to the terminal by the H330 0 Disable 1 Enable The default value is 0 lt mode gt Call waiting service request to the network When the lt mode gt parameter is not given the network is not interrogated 0 Disable 1 Enable 2 Query status lt class gt Sum of integers each representing a class of information Please see class table in CCWA command The default value is 7 lt number gt Calling line number The number format is specified by lt type gt lt type gt Type of address octet in integer format 145 Default when the dialing string includes the international access code character 129 Default when making a local call 128 Type of number is unknown usually the output when the number itself is unknown lt status gt Call waiting support by the network output for lt mode gt 2 0 Not active 1 Active lt alpha gt Name of the calling party if provided by the network lt
103. C_BUSY 1 PARAMETER_ERROR 2 INVALID_NUMBER 3 OUTGOING_CALL_BARRED 4 TOO_MANY_CALLS_ON_HOLD 5 NORMAL 6 DROPPED 10 NETWORK 12 INVALID_CALL_ID 13 NORMAL_CLEARING 14 H330 Module AT Command User Manual Page 88 of 304 Bs FIBOCOM Termination Cause Index TOO_MANY_ACTIVE_CALLS 16 UNASSIGNED_NUMBER 17 NO_ROUTE_TO_DEST 18 RESOURCE_UNAVAILABLE 19 CALL_BARRED 20 USER_BUSY 21 NO_ANSWER 22 CALL_REJECTED 23 NUMBER_CHANGED gt A DEST_OUT_OF_ORDER 35 SIGNALING_ERROR 26 NETWORK_ERROR 27 NETWORK_BUSY 28 NOT_SUBSCRIBED 29 SERVICE_UNAVAILABLE 31 SERVICE_NOT_SUPPORTED 32 PREPAY_LIMIT_REACHED 33 INCOMPATIBLE_DEST 35 ACCESS_ DENIED 43 FEATURE_NOT_AVAILABLE ji WRONG_CALL_STATE F SIGNALING_TIMEOUT a7 MAX_MPTY_PARTICIPANTS_ EXCEEDED 48 SYSTEM_FAILURE 49 DATA_MISSING 50 BASIC_SERVICE_NOT_PROVISIONED 51 ILLEGAL_SS_OPERATION 52 SS_INCOMPATIBILITY 53 SS_NOT_AVAILABLE 54 SS_SUBSCRIPTION_VIOLATION 55 INCORRECT_PASSWORD 56 TOO_MANY_PASSWORD_ATTEMPTS 57 H330 Module AT Command User Manual Page 89 of 304 Bs FIBOCOM Termination Cause Index PASSWORD_REGISTRATION_FAILURE 58 ILLEGAL_EQUIPMENT 59 UNKNOWN_ SUBSCRIBER 60 ILLEGAL_SUBSCRIBER 61 ABSENT_SUBSCRIBER 62 USSD_BUSY T 63 CANNOT_TRANSFER_MPTY_CALL 65 BUSY_WITH_UNANSWERED_C
104. Call Related Supplementary Services Command This command controls the Call Hold and Multiparty Conversation services This command manipulates voice calls only The Set command allows the control of the following call related services H330 Module AT Command User Manual Page 58 of 304 Bs FIBOCOM Call HOLD A call can be temporarily disconnected from the H330 but the connection is retained by the network MTPY Multi party Conversation Conference calls The network does not reserve more than one traffic channel for a mobile station therefore the H330 can have only one call on hold at a time Note Only voice calls can be put on HOLD A precondition for the multi party service is that the H330 is in control of one active call and one call on hold In this situation the H330 can request the network to begin the MTPY Multi Party service Once a MTPY call is active remote parties may be added disconnected or separated removed from the MTPY call but remain connected to the served mobile subscriber The maximum number of remote parties is 5 In this command the term CALL refers to a single or MTPY call Asingle Active call is considered a MTPY call with one call index numbered as 1 Command Response Action CHLD lt n gt If the call is terminated OK approve request was submitted NO CARRIER If the call state is changed link split from active to hold and so on OK approve request was do
105. Cells Summary screen 12 Reselection Re selection screen 13 Hopping Info Dedicated TBF modes Hopping Information screen 14 PDP Context PDP Context Information screen 15 18 GPRS Parameters Idle Packet Idle mode GPRS parameters 19 Sysinfos Idle Packet Idle mode Optional SYSINFO 20 H330 Module AT Command User Manual Page 169 of 304 Bs FIBOCOM Example AT MCELL OK AT MCELL MCELL 0 1 20 OK AT MCELL 0 3 OK MCELL Serving Misc P BCCH ARFCN 00536 BSIC 056 RxLev 037 Cell ID 03583 PD TCH ARFCN INVALID_ARFCN Timeslot 00 CBA 000 CBQ 000 T3314 00 AT MCELL 0 19 OK MCELL GPRS Parameters P BCCH ARFCN 00536 BSIC 056 RxLev 039 Cell ID 03583 PD TCH ARFCN INVALID_ARFCN Timeslot 00 BS_PA_MFRMS 02 BS_AG_BLK_RES 01 BS_PAG_BLK_RES 0 BS_PBCCH_BLOCKS 1 9 1 11 MCI H330 Cell Information This command only support when module register GSM net UMTS not supported This command returns neighbor cell information The command returns ARFCN BSIC and RX level of serving and adjacent cells In case H330 is registered adjacent cells are from registered PLMN In case H330 is in Emergency Mode adjacent cells are physical neighbors BSIC is displayed only in case SCH Synchronization Channel is decoded The parameter lt enable_TA gt determines whether lt TA gt will be reported by MCI command lt TA gt is defined for serving cell only This value will be displayed only in Dedicated mode The command output
106. D lt OK Used to send data to source gt lt data gt Or UART2 CME ERROR lt err gt Test AT UARTSEND UARTSEND lt source gt lt data gt Return supported values OK or ERROR The following table shows the GPIO parameters lt Parameter gt Description lt source gt 3 For internal reason 3 indicates UART2 here and only 3 is supported lt data gt O F The data should be wrap up with and the valid character is 0 F Example AT UARTSEND 3 30313233 OK UART2 will output 0123 AT UARTSEND UARTSEND 3 data H330 Module AT Command User Manual Page 192 of 304 Bs FIBOCOM 11 Audio 11 1 Scope This section describes the Audio features which includes the following configuration items Path Selection of microphone and speaker to be used Gain Control of volume levels for rings voice etc Algorithm Activation of audio algorithms echo cancellation noise suppression and sidetone Audio Control of Path Gain and Algorithms is available by these two different modes sets of commands It is advised to select the audio mode according to the application needs 11 2 General Audio Commands The following audio commands can be used in audio modes VTD VTS CALM MMICG 11 2 1 CRSL Call Ringer Level This command handles the selection of the incoming call ringer sound level on the curremt speaker of the H330 The new value remains after po
107. DP context s with respect to QOS profiles and TFTs Command Syntax Response Action Remarks Set CGCMOD OK The set command is used to lt cid gt L lt cid gt Or modify the specified PDP aii context s with respect to CME ERROR lt error gt QoS profiles and TFTs Test CGCMOD CGCMOD list of lt cid gt s associated The test command returns a with active contexts list of lt cid gt s associated with OK active contexts The following table shows the CGCMOD parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands Example AT CGDCONT CGDCONT 1 IP CMNET 1 72 29 107 202 0 0 CGDCONT 2 1P 0 0 0 0 1 1 CGDCONT 3 IP CMNET 0 0 0 0 0 0 CGDCONT 4 IP CMNET 0 0 0 0 0 0 H330 Module AT Command User Manual Page 236 of 304 Bs FIBOCOM CGDCONT 6 IPV6 CDOE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OK AT CGCMOD 1 1 OK AT CGCMOD 1 1 6 OK AT CGDCONT CGDCONT 1 IP CMNET 1 72 29 107 202 0 0 CGDCONT 2 IP 0 0 0 0 1 1 CGDCONT 3 IP CMNET 0 0 0 0 0 0 CGDCONT 4 IP CMNET 0 0 0 0 0 0 CGDCONT 6 IPV6 CDOE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OK AT CGCMOD CGCMOD 1 2 3 4 6 OK 13 2 15 CGDATA _ Enter Data State This execution command causes the MT to perform whatever actions are necessary to establish communication bet
108. Data gt The following table hows the MIPRUDP parameters lt Parameter gt Description Source_IP IP of the source Source_Port Port of the source Socket_ID 1 2 3 4 Number of valid sockets Left Size of received Data still left in protocol stack SDL Subsequent data length Data Data string received with 0 F hexadecimal digits String ends with a lt CR gt Note e This unsolicited event will change the destination IP and destination port it means that when a MIPRUDP unsolicited event coming if you do not specify IP and port using MIPPUSH data left in the buffer will be sent to this new destination by default e If IPRFMT parameter has been set by AT GTSET the receives data will be reponse at different format 14 11 MIPRTCP Receive Data from TCP Protocol Stack This unsolicited event is sent by the H330 to the terminal when data is received from the TCP protocol stack Set Command Event MIPRTCP lt socket_ID gt lt Left or SDL gt lt Data gt The following table shows the MIPRTCP parameters lt Parameter gt Description Socket_ID 1 2 3 4 Number of valid sockets Left Size of received Data still left in protocol stack SDL Subsequent data length Data Data string received with 0 F hexadecimal digits String ends with a lt CR gt Note e This unsolicited event will change the destination IP and destination port it means that when a
109. E3 e g CGEQNEG 5E3 refer TS 24 008 subclause 10 5 6 5 lt Residual bit error ratio gt A string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 510 3 would be specified as 5E3 e g CGEQNEG 5E3 refer TS 24 008 subclause 10 5 6 5 lt Delivery of erroneous SDUs gt Anumeric parameter that indicates whether SDUs detected as erroneous shall be delivered or not 0 no 1 yes 2 nodetect Other values are reserved H330 Module AT Command User Manual Page 235 of 304 Bs FIBOCOM lt Parameter gt Description lt Transfer delay gt Anumeric parameter 0 1 2 that indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds refer TS 24 008 subclause 10 5 6 5 priority gt lt Traffic handling A numeric parameter 1 2 3 that specifies the relative importance for handling of all SDUs belonging to the UMTS bearer compared to the SDUs of other bearers refer TS 24 008 subclause 10 5 6 5 Example AT CGEQNEG CGEQNEG OK 13 2 14 CGCMOD PDP Context Modify The execution command is used to modify the specified P
110. Example AT CPMS CPMS SM 13 50 SM 13 50 SM 13 50 OK AT CMGR 1 CMS ERROR invalid index AT CMGR 142 CMGR STO SENT 054565034 message text OK AT CSDH 1 OK AT CMGR 142 CMGR STO SENT 054565034 129 25 0 0 05 04 03 21 22 23 08 97254120032 145 lt message length gt message text OK H330 Module AT Command User Manual Page 131 of 304 Bs FIBOCOM AT CMGW 18 gt 079179521201009511000c917952428650290004AA044 1424344 CMGW 143 OK AT CMGR 143 CMGR 2 23 0791795212010095040C91 7952428650290004502032110201800441424344 OK AT CPMS SM change to SM to read SMS DELIVER messages CPMS 2 20 11 61 2 20 OK AT CMGR 1 CMGR REC READ 972544565034 05 02 23 11 20 10 08 145 4 0 4 97254120032 145 4 41424344 OK AT CMGF 0 OK AT CMGR 1 CMGR 0 23 0791 07917952140230F2040C917952446505430004502032110201800441424344 OK AT CMGR 14 CMGR 0 25 079179521201009506BC0B91 7952428600F05080308075 128050803080751 28046 SMS STATUS REPORT message in PDU mode OK AT CMGF 1 OK AT CMGR 14 SMS STATUS REPORT message in Text mode CMGR REC READ 6 188 97252468000 145 05 08 03 08 57 21 08 05 08 03 08 57 21 08 70 OK 7 1 16 CMSS Send Message from Storage This command sends a pre stored message written previously using the CMGW command The lt da gt lt toda gt parameters are optional If a DA is given the message is sent to that address Othe
111. G The test command displays all supported lt count gt lt size gt lt TTL parameters values for MPING set command gt lt TOS gt lt TimeOut gt OK The following table shows the MPING command parameters lt Parameter gt Description lt mode gt 0 Abort current ping request execution 1 Launch new ping request There is no default value appropriate ERROR will be displayed if parameter is not supplied lt Destination_IP host name gt Specifies the target machine computer which is identified either by IP address 4 octets long in dotted decimal notation or by host name of maximum 255 not including double quotes characters long in dotted notation Each octet of IP address has valid value range of 0 to 255 Host names are not case sensitive and can contain alphabetic or numeric letters or the hyphen There is no default value appropriate ERROR will be displayed if parameter is not supplied H330 Module AT Command User Manual Page 266 of 304 Bs FIBOCOM lt Parameter gt Description lt count gt Specifies a number of Internet Control Message Protocol ICMP Echo Request messages to send Valid value range is from 1 to 255 The default value is 4 lt size gt Specifies the length in bytes of the Data field in the Echo Request messages sent The minimum size is 0 The maximum size is 1372 The default value is 32 lt TTL gt Time To Live TTL
112. H330 Module AT Command User Manual Page 296 of 304 Bs FIBOCOM 31 32 40 4 42 43 44 45 46 47 48 49 50 100 103 106 107 111 112 113 114 116 117 132 133 134 135 148 149 150 244 257 network timeout network not allowed emergency calls only network personalisation PIN required network personalisation PUK required network subset personalisation PIN required network subset personalisation PUK required service provider personalisation PIN required service provider personalisation PUK required corporate personalisation PIN required corporate personalisation PUK required hidden key required NOTE This key is required when accessing hidden phonebook entries EAP method not supported Incorrect parameters unknown Illegal MS Illegal ME GPRS services not allowed PLMN not allowed location area not allowed roaming not allowed in this location area GPRS services not allowed in this PLMN MSC temporarily not reachable Network failure Service not supported Service not subscribed service option temporarily out of order NS api already used Unspecified GPRS error PDP authentication error invalid mobile class Attach failure Invalid error mapping H330 Module AT Command User Manual Page 297 of 304 Bs FIBOCOM 258 APN not listed in APN Control List ACL
113. ID This command returns the card identification number in SIM SIM file EFICCID see GSM 11 11 Chap 10 1 1 as string type Command Syntax Response Action Set AT CCID CCID lt ID gt OK or CME ERROR lt err gt Read AT CCID Same as above Test AT CCID OK H330 Module AT Command User Manual Page 38 of 304 Bs FIBOCOM Example AT CCID CCID 89860018190839008096 OK AT CCID OK AT CCID CCID 89860018190839008096 OK 4 2 Sleep Mode Commands When the H330 is connected using UART connection to external device a sleep mechanism is available In order to improve the power consumption the H330 supports a low power consumption mode called Sleep mode The H330 has internal decision conditions for entering and exiting sleep mode As the terminal and the H330 operate in a combined system and as the communication between the H330 and the terminal must be reliable there should be a mechanism agreed upon by both the H330 and the terminal to coordinate their separate sleep mode entering and exiting sequences The H330 will not enter sleep mode unless the terminal enables the H330 by AT commands The following are the Sleep mode AT commands ATS24 Activates deactivates Sleep mode The H330 receives a request to activate or deactivate Sleep mode 4 2 1 S24 Set Number of Seconds Delay Before H330 Enters Sleep Mode This command activates disables the Sleep mode The terminal sends
114. ILE 0 profile data STORED PROFILE1 profile data OK or CME ERROR lt err gt Example AT amp V ACTIVE PROFILE amp C1 amp D2 amp K3 E1 QO V1 XO YO S00 000 S02 043 S03 013 S04 010 S05 008 07 030 12 020 CBST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 STORED PROFILE 0 amp C1 amp D2 amp K3 E0 QO V1 XO S00 000 02 043 S03 013 04 010 S05 008 07 030 12 020 CBST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 STORED PROFILE 1 amp C1 amp D2 amp K3 E1 QO V1 XO S00 000 02 043 S03 013 04 010 S05 008 07 030 12 020 CBST 007 000 001 CRLP 061 061 048 006 CR 000 CRC 000 OK H330 Module AT Command User Manual Page 30 of 304 Bs FIBOCOM 4 1 9 amp F Set to Factory Defined Configuration This command restores the factory default configuration profile The H330 only supports one factory default profile 0 Command Syntax Response Action Remarks Set AT amp F lt value gt OK or CMS ERROR lt err gt Read AT amp F lt current profile number gt Test The Test command for amp F is not defined by ITU and therefore is not supported by the H330 The H330 returns an error The following table shows the amp F parameters lt Parameter gt Description lt value gt 0 Factory default configuration profile This is the only value supported Example AT amp
115. If the MT call fails the possible notifications are NO CARRIER Connection Failure H330 Module AT Command User Manual Page 49 of 304 Bs FIBOCOM ERROR General Failure Note A waiting call an incoming call while a call is in progress is announced by CCWA rather than RING A waiting call can be answered only if it is a voice call The waiting voice call should be answered using the ATA command which will put the active call on hold and will connect the waiting call making it the active call This ATA action is the same action as AT CHLD 2 Example Example Answering a voice call AT CRC 1 CRING VOICE CRING VOICE ata OK VOICE call connected H330 is in Command mode ath OK NO CARRIER Example Answering a data call CRING REL ASYNC CRING REL ASYNC ata Connecting dots are not displayed OK DATA call connected H330 is in Online Data mode Note In aCSD call call release is not valid during the phase of call negotiation from OK until connect call 5 3 6 CRC Cellular Result Codes and RING CRING Incoming Call Indication This command controls whether or not to present the extended format of an incoming call indication The RING CRING indication is sent from the H330 to the terminal when the H330 is alerted by an incoming call from the network Once this indication is sent information is available on the calling line via CLIP When CRC is disabled the indication is RING and when
116. LM lt callmode gt OK The Set command sets the alert lt smsmode gt dr sound mode CME ERROR lt err gt Read CALM CALM lt mode gt The Read command displays the OK current alert sound mode setting Test CALM CALM list of The Test command displays the list supported of supported modes lt callmode gt lt smsmode gt s OK H330 Module AT Command User Manual Page 196 of 304 Bs FIBOCOM The following table shows the CALM parameters lt Parameter gt Description lt callmode gt Alert sound mode of the H330 0 new call play tone default 1 new call Silent mode ring prevented lt smsmode gt 0 new sms play tone 1 new sms Silent mode ring prevented Note Selecting the ring mode with this command retrieves the current alert volume level setting 11 2 7 VTD Tone Duration This command handles the selection of tone duration An integer lt n gt defines the length of tones emitted as aresult of the VTS command This command does not affect the D dial command In this command the new value is saved after power down Note In GSM the tone duration value can be modified depending on the specific network Command Syntax Response Action Remarks Set VTD lt n gt OK The Set command sets the tone duration or CME ERROR lt err gt Read VTD VTD lt n gt The Read command displays the OK current tone duration Test VTD VTD list of supported
117. MICG parameters Set MMICG lt gai OK TheSetcommandsetsthe n gt r microphone gain value CME ERROR lt err gt Read MMICG MMICG lt gain gt The Read command displays the OK current microphone gain Test MMICG MMICG list of The Test command displays the list supported lt gain gt s of supported gain values OK lt Parameter gt Description lt gain gt Microphone gain values H330 Module AT Command User Manual 0 15 Ois lowest gain value not mute The default value is 8 Page 206 of 304 Bs FIBOCOM 12 Multiplexer Feature The MUX provides multiple logical communication channels between the DTE and H330 over one physical RS232 or USB connection This service enables the DTE device to run multiple applications such as GPRS CSD SMS and voice calls while communicating simultaneously with the H330 The H330 can be supports the multiplexing protocol control channel as defined in GSM07 10 and only basic mode 12 1 CMUX MUX Startup Command This command is used to start the GSM MUX multiplexing protocol stack When the H330 received a valid CMUX command it returns OK and changes its state to MUX Init If the parameters are left out the default value is used Command Syntax Response Action Remarks Set CMUX lt mode gt lt subset gt lt p CME ERROR lt err gt The Set command ort_speed gt lt N1 gt lt T1 gt lt N2 gt requests the H33
118. OK Test MSTART MSTART 0 1 0 1 OK The following table shows the MSTART parameters lt Parameter gt Description lt at start gt 0 Do not output AT command ready from UART 1 Output AT command ready from UART default value lt sim ready gt 0 Do not output SIM READY after SIM init OK 1 Output SIM READY after SIM init OK default value Notes AT command ready can not output from USB port even if set to 1 SIM READY can output from UART and USB port according to setting Example AT MSTART MSTART 0 1 0 1 OK AT MSTART 1 1 OK AT MSTART MSTART 1 1 OK 10 2 8 MSMPD Enable Disable SIM card hot plug This command can Enable Disable SIM card hot plug feature The default status is disable this feature The parameter will be saved in NVM and can restore at power cycle Command Syntax Response Action Remarks Set AT MSMPD lt status gt OK Enable Dlasble SIM card hot Or plug CME ERROR lt err gt Read AT MSMPD MSMPD lt status gt Read the current status OK H330 Module AT Command User Manual Page 189 of 304 Bs FIBOCOM The following table shows the MSMPD parameters lt Parameter gt Description lt status gt 0 Disable the SIM card hot plug feature 1 Enable the SIM card hot plug feature The default value is 0 10 2 9 GPIO Set and Read GPIO This command int
119. Operator Selection ecessssescssescsseecsseccsseccsseecsseessseessseessseesseecsueecssecesneecaseccsseessseesseesnessneeess 157 9 1 6 F CPOL Preferred Operators ssssccsssscccsseccsssescesnssesssecessussessuscessnseeessseccesueecssuecesssceessseeessneeessnseessnees 160 9 1 7 CBAND Change Radio Band o sesssssscsssscsssccsseecsseecsseccsseesssecsssesssscesucecsuecesneessseccsseesssessnseesneesneeess 163 9 1 8 CUBAND Change 3G Radio Band essssssssssssscssseesseecsseccsseecsssccsseccsseccsseesssecsneesseecsueeesseeesseessee 165 9 1 9 XREG Current Network Registration Status ssscssescssescsseecsseecsseecsseecsecsneecsseeesueeesseeesseeeaee 166 H330 Module AT Command User Manual Page 7 of 304 Bs FIBOCOM 9 1 10 MCELL H330 Cell Description esssssscssssccsssccsseccsscscsscessscsssecesssesssscenesseneeeeneessseeseneessnceseneesseses 168 9 1 11 FMI H330 Cell Information ssssscsssssccssssccssssccsssseccsseccssusecesnscessssecessueeessusecesnsccesssecessneecesnseesssees 170 9 1 12 GTRAT Selection of Radio Access TeECHnOlogy sssssccssssscssssssesssssessnseessnssessnssesssseeessneecssneesssees 173 10 Hardware for mationy csvessiccssccsscsscccsnssts cvcicrnstaccnsccanasavecaveceunsececon cncosecchaushotansechansecesnvssosnivacesgcenoscesbnssecosustchavsbecancccauasaves 174 10 1 Udrt Parameter Commas sssini oieee ne eee kine eee ea Eaei 174 10 1 1 CBAUD Baud Rate Regulation ssssssssssseccsesssssssssseeccce
120. PPWD OK FTPPWD lt directory_name gt indicates the current lt result gt lt directory_ working directory The command name gt or ERROR execution result return to the user as an lt error_code gt unsolicited response 0 operation fails 1 operation success 2 String follows is the current working directory Read FTPPWD ERROR Not supported Test FTPPWD ERROR Not supported Example AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test is current directory FTPPWD 2 export home test is current directory FTPPWD 1 15 9 FTPCDUP Change Directory up This command changes the current directory to root directory of remote file system there is no need to change the login account information or transimission parameter Command Syntax Response Action Remarks Set FTPCDUP OK Re FTPCDUP The command execution result lt result gt or ERROR return to the user as an unsolicited lt error_code gt response 0 operation fails 1 operation success Read FTPCDUP ERROR Not supported Test FTPCDUP ERROR Not supported H330 Module AT Command User Manual Page 281 of 304 Bs FIBOCOM Example AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test 1234 is current directory FTPPWD 2 export home test 1234 is current directory FTPPWD 1 AT FTPCDUP FTPINFO CDUP OK FTPINFO 250 CWD command successf
121. PSTAT 2 FTPSTAT 2 FTPSTAT 2 211 End of status FTPSTAT 1 Logged in as ftp TYPE ASCII No session bandwidth limit Session timeout in seconds is 120 Control connection is plain text Data connections will be plain text 4096Apr 22 2001 usr At session startup client count was 226 vsFTPd 2 0 5 secure fast stable 15 14 FTPSYST Request Operating System Type This command is used for requesting the operating system type of the server Command Syntax Response Action Remarks Set FTPSYST OK w FTPSYST The command execution result return to the lt result gt lt system gt or user as an unsolicited response ERROR lt error_code gt 3 i 0 operation fails 1 operation success 2 data follows Read FTPSYST ERROR Not supported Test FTPSYST ERROR Not supported Example AT FTPSYST OK FTPSYST 2 UNIX Type L8 Version SUNOS FTPSYST 1 H330 Module AT Command User Manual Page 286 of 304 Bs FIBOCOM FTPNOOP No Operation This is ano operation command which means it doesn t do anything 15 15 Note FTPNOOP doesn t affect any parameter or earlier command It doesn t do anything except request the server to send a response Command Syntax Response Action Remarks Set FTPNOOP OK FTPNOOP The command execution result lt result gt or ERROR return to the user as an unsolicited lt error_code gt response 0 o
122. Query mode return only the active lt fac gt In case no lt fac gt is active the query will return the default 7 lt class gt Sum of integers each representing a class of information Please see class table in CCWA command The default value is 7 lt status gt 0 Inactive 1 Active Example AT CLCK H330 Module AT Command User Manual Page 150 of 304 Bs FIBOCOM CLCK SC AO OL OX AI IR ABYAG AC FD OK AT CLCK SC 2 CLCK 0 OK AT CLCK SC 1 CME ERROR operation not allowed AT CLCK SC 1 incorrect password CME ERROR incorrect password AT CLCK SC 1 correct password OK From now SIM Card is locked and PIN is requested on power up AT CLCK AB 0 incorrect password CME ERROR incorrect password AT CLCK IR 2 CLCK 0 1 CLCK 0 2 CLCK 0 4 CLCK 0 8 OK AT CLCK IR 1 correct password lt classx gt is defaulted to 7 when not specified OK AT CLCK IR 2 CLCK 1 1 CLCK 1 2 CLCK 1 4 CLCK 0 8 OK AT CLCK O0l 1 correct password 3 OK Voice and data international calls barred fax and SMS not barred AT CLCK 01 2 CLCK 1 1 CLCK 1 2 CLCK 0 4 CLCK 0 8 OK H330 Module AT Command User Manual Page 151 of 304 Bs FIBOCOM 9 Network 9 1 Network Commands 9 1 1 CSQ Signal Strength This command displays the received signal strength indication lt rssi gt and channel bit error rate lt ber gt from the H330 Command Syntax Response Action Execute Read A
123. R 2 OK atd054565195 MO voice call OK a H330 that has 054565195 SIM and is CLIP enabled will receive the following on the terminal calling RING CLIP 128 128 1 RING CLIP 128 128 1 ath NO CARRIER OK AT CLIR 0 OK atd054565195 MO voice call OK calling a H330 that has 054565195 SIM and is CLIP enabled will receive the following on the terminal RING CLIP 054565006 129 128 0 RING CLIP 054565006 129 128 0 ath OK NO CARRIER H330 Module AT Command User Manual Page 65 of 304 Bs FIBOCOM 5 3 14 CBST Select Bearer Service Type This command sets the bearer service data circuit duplex asynchronous and synchronous It chooses one of the bearer services the data rate of the service actually the modulation when modem IWFs are used and enables or disables the Radio Link Protocol Command Syntax Response Action Remarks Set AT CBS OK The Set command selects the bearer T lt spe CME ERROR lt err gt service lt name gt with data rate lt speed gt ed gt lt n and the connection element lt ce gt to be ame gt lt used when data calls are originated refer ce gt to GSM 02 02 Values may also be used during mobile terminated data call setup especially in the case of single numbering scheme calls Note For incoming calls the bearer service will be taken automatically from incoming parameters and not ac
124. S Unsolicited Response New SMS STATUS REPORT Receipt The CDS unsolicited response is sent to the TE upon receipt of anew mobile terminated SMS if the CNMI parameter lt ds gt is set to 1 This unsolicited message displays the received SMS DELIVER message Unsolicited Response In text mode CMGF 1 H330 Module AT Command User Manual Page 123 of 304 Bs FIBOCOM CDS lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt st gt lt CR gt lt LF gt In PDU mode CMGF 0 CDS lt length gt lt CR gt lt LF gt lt pdu gt H330 Module AT Command User Manual Page 124 of 304 Bs FIBOCOM The following table shows the CDS parameters lt Parameter gt Description lt fo gt First octet of the SMS lt mr gt Message Reference lt ra gt Message Recipient address lt tora gt Type of Recipient address lt scts gt Service center time stamp lt dt gt Discharge Time lt st gt Status After sending a CDS unsolicited response to the TE the H330 will expect a CNMA new message acknowledgement from the TE within a predefined timeout of 15 seconds Within the timeout the H330 will not send another CDS unsolicited response to the TE before the previous one is acknowledged If the CDS is acknowledged within the timeout the new SMS is not saved in the message storage If the H330 does not receive acknowledgment within the required time CNMI parameters will NOT be res
125. Specifies number of hops hop is one step from one router to the next on the path of a datagram on an IP network which the Echo Request message may be routed over The value is set by using TTL field in IP header Valid value range is from 1 to 255 The default value is 64 lt TOS gt lt TimeOut gt The Type Of Service TO S is for internet service quality selection The type of service is specified along the abstract parameters precedence delay throughput and reliability These abstract parameters are to be mapped into the actual service parameters of the particular networks the datagram traverses Minimum and maximum values for TOS are 0 and 255 respectively Refer to RFC 791 and RFC 2474 which obsoletes RFC 791 for TOS defined values The default value is 0 Specifies the amount of time in milliseconds to wait for the Echo Reply message that corresponds to a sent Echo Request message measured after Echo Request message was sent If the Echo Reply message is not received within the time out MPINGSTAT The following table shows the MPING unsolicited response parameters lt Parameter gt Description lt Destination_IP gt Specifies the message sender machine computer which is identified by IP address 4 octets long in dotted decimal notation Each octet of IP address has valid value range of 0 to 255 The message sender machine computer may be either the target of Echo Requestmessage if a res
126. Syntax Response Action Remarks Set CPMS lt mem1 gt CPMS The Set command sets lt mem2 gt lt mem3 lt used1 gt lt total1 gt lt used2 gt lt total2 the memory storage gt gt lt used3 gt lt total3 gt OK or CMS ERROR lt err gt Read CPMS CPMS The Read command lt mem1 gt lt used1 gt lt total1 gt lt mem2 Mispleye Me seleried gt lt used2 gt lt total2 gt lt mem3 gt lt use MEMO Ly Stole YE d3 gt lt total3 gt for the three memory areas OK or CMS ERROR lt err gt Test CPMS CPMS list of The Test command supported lt mem1 gt s list of lists the supported supported lt mem2 gt s list of memory storage for supported lt mem3 gt s lt mem1 gt lt mem2 gt OK and lt mem3 gt or CMS ERROR lt err gt H330 Module AT Command User Manual Page 106 of 304 Bs FIBOCOM The following table shows the CPMS parameters lt Parameter gt Description lt mem1 gt Memory from which messages are read and deleted Supported values are SM BM ME SR The default value at power up is SM lt mem2 gt Memory to which writing operation is made Supported value is SM ME The default value at power up is SM lt mem3 gt Memory to which received SMS are stored unless forwarded directly to TE Supported value is SM BM ME SR The default value at power up is SM BM Broadcast message storage SM U SIM message storage ME
127. T CSQ CSQ lt rssi gt lt ber gt AT CSQ OK Test AT CSQ CSQ list of supported lt rssi gt s list of supported lt ber gt s OK The following table shows the CSQ parameters lt Parameter gt Description 0 113 dBm or less 1 111 dBm 2 30 109 53 dBm 31 51 dBm or greater 99 not known or not detectable lt rssi gt 0 through 31 covers the range of 113 dbm or less to 51 dbm or greater lt ber gt Channel bit error rate in percent 99 Unknown or not detectable 0 7 RXQUAL values in the TS 45 008 table Example AT CSQ CSQ 23 99 OK AT CSQ CSQ 0 31 99 0 7 99 OK H330 Module AT Command User Manual Page 152 of 304 Bs FIBOCOM 9 1 2 CRLP Radio Link Protocol This command displays the Radio Link Protocol parameters that are used when non transparent data calls are originated Command Syntax Response Action Remarks Set CRLP lt iws OK Whasercommeand gt L lt mws gt L lt T 1 gt L lt N2 gt or enables you to change gt lt N2 gt CME ERROR lt err gt the RLP parameters Read CRLP CRLP lt iws gt lt mws gt lt T1 gt lt N2 gt OK Test CRLP CRLP list of supported lt iws gt s list of supported lt mws gt s list of supported lt T1 gt s list of supported lt N2 gt s OK The following table shows the CRLP parameters lt Parameter gt Description lt iws
128. T MTSM Read the current setting MTSM 0 OK H330 Module AT Command User Manual Page 187 of 304 Bs FIBOCOM 10 2 6 WRIM RI signal width setting In IDLE Mode H330 s RI pin is High voltage level When H330 receive a SMS or Call This pin can output a Low voltage pulse This command defines the width of pulse can be set OK or ERROR Command Syntax Response Action Remarks Set WRIM lt ty OK Set width pe gt lt width or gt ERROR Read WRIM WRIM lt type gt lt width gt The read command returns the OK current parameter of RI pin or ERROR Test WRIM WRIM lt type gt lt width gt The test command displays the list of supported lt type gt and lt width gt values The following table shows the WRIM parameters lt Parameter gt Description lt type gt 0 make effective on Call 1 make effective on SMS lt width gt 0 default value 0 1000 and 1 150 12000 1 2000ms Example AT WRIM WRIM 0 1 0 2000 OK AT WRIM 1 1000 OK AT WRIM WRIM 0 1000 WRIM 1 1000 OK 10 2 7 MSTART Start message notification This command can Enable Disable H330 output start message when power up H330 Module AT Command User Manual Page 188 of 304 Bs FIBOCOM Command Syntax Response Action Set MSTART lt at start gt lt sim ready gt OK or ERROR Read MSTART MSTART lt at start gt lt sim ready gt
129. TAT lt Socket_ID gt lt Status gt or ERROR lt err gt Read AT MIPODM MIPODM lt Socket_ID gt When a socket opens in for each socket that can be Online Data Mode the opened command returns actual H330 Module AT Command User Manual Page 272 of 304 Bs FIBOCOM or Socket_ID value a d 1 value MIPODM 0 0 active H330 will be in if there are no free sockets pseudo command mode for receiving the command Test AT MIPODM MIPODM list of supported lt socket_ID gt s list of supported lt source port gt s list of support d lt Destination IP gt s list of lt destination port gt s list of supported lt protocol gt s list of supported lt Pseudo Command Mode state gt s The following table shows the MIPODM parameters lt Parameter gt Description Socket_ID A unique number that identifies a connection Valid socket numbers 1 2 3 and 4 Source Port Port of source site Port range 1 65535 decimal digits Remote IP IP of the remote site in the form t AAA BBB CCC DD The range of each octet is 0 255 The value can be written in 1 2 or 3 digits Host name of remote site The host name convention should meet the rules as describe in RFC 1035 section 2 3 Conventions Syntax is not validated except the maximum length 255 characters Remote Port Port of remote site Port range 1 65535 decimal digits for outgoing connection Po
130. TPCLOSE ERROR Not supported Test FTPCLOSE ERROR Not supported Example at ftpclose OK FTPCLOSE 1 at ftpclose ERROR at cmee 2 OK at ftpclose close connection close error close successful CME ERROR FTP session is inactive FTP is inactive 15 4 FTPINFO FTP Unsolicited Indication Enable Disable This command can enable or disable FTP unsolicited indication when it is enabled it will print the command send by FTP and data information returned by FTP Server This is only used for indentifying the problem when FTP is abnormal if FTP works fine unsolicited indication is disabled Command Syntax Response Action Remarks Set FTPINFO lt indicat ion gt OK Or ERROR lt error_code gt Enables disables FTP unsolicited indication 0 Indication disabled 1 Indication enabled When indication is enabled module will send user all FTP commands and response by the following format FTPINFO lt data gt H330 Module AT Command User Manual Page 277 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read FTPINFO FTPINFO Returns FTP indication status lt indication gt OK 9 _ indication disabled 1 Indication enabled Test FTPINFO FTPINFO range Return command format of supported lt indication_statu s gt s OK The following table shows the FTPINFO parameter lt Parameter gt
131. The Test command displays the list of lt n gt s supported tone durations OK The following table shows the VTD parameters lt Parameter gt Description lt n gt Defines the length of tones emitted by the VTS command 1 10 100mS to 1S adjustable 11 2 8 VTS Command Specific Tone Duration This command transmits a string of DTMF tones when a voice call is active DTMF tones may be used for example when announcing the start of a recording period The duration does not erase the VTD duration Note In GSM the tone duration value can be modified depending on the specific network If the active call is dropped in the middle of playing a DTMF tone the following unsolicited message H330 Module AT Command User Manual Page 197 of 304 Bs FIBOCOM transfers to TE VTS Call termination stopped DTMF tones transmission Command Syntax Response Action Remarks Set VTS lt DTMF OK The Set command sets the tone gt L lt duration gt o and duration if entered CME ERROR lt err gt Test VTS VTS list of supported The Test command displays the lt DTMF gt list of supported lt durations gt s OK list of supported DTMF tones and tone lengths The following table shows the VTS parameters lt Parameter gt Description lt DTMF gt String of ASCII characters 0 9 String length is up to 32 characters long lt duration gt A DTMF tone
132. User Manual Page 136 of 304 Bs FIBOCOM The following table shows the CMGD parameters lt Parameter gt Description lt index gt 1 352 Index in the SMS memory of the message to be deleted lt delflag gt 0 Deletes the message specified in lt index gt 1 Deletes all read messages 2 Deletes all read messages and sent MO messages 3 Deletes all read messages sent and unsent MO messages 4 Deletes all messages Example AT CMGD 4 OK AT CMGD 1 3 OK 7 1 19 CGSMS Select Service for MO SMS Messages This command handles the selection of the service or service preference used by the H330 to send mobile originated SMS messages Note The Set command selects the service or service preference used to send SMS messages The value that is set is retained after a power cycle Command Syntax Response Action Remarks Set CGSMS OK The Set command selects the service or lt servi CME ERROR lt err gt service preference used to send SMS ce gt messages The value that is set is retained after a power cycle nead K PERE M Ss Service The Read command displays the current i OK SMS service preference setting Test CGSMS CGSMS list of The Test command displays a list of currently available lt service gt s on the currently available network lt service gt s OK H330 Module AT Command User Manual Page 137 of 304 Bs FIBOCOM The following table shows the CGSMS parameters
133. X 31 flag stuffing this setting can be used in conjunction with asynchronous non transparent UDI or RDI service in order to get FTM 84 64000 bps X 31 flag stuffing this setting can be used in conjunction with asynchronous non transparent UDI service in order to get FTM 115 56000 bps bit transparent H330 Module AT Command User Manual Page 67 of 304 Bs FIBOCOM 116 64000 bps bit transparent 120 32000 bps PIAFS32k 121 64000 bps PIAFS64k 130 28800 bps multimedia 131 32000 bps multimedia 132 33600 bps multimedia 133 56000 bps multimedia 134 64000 bps multimedia The default value is 7 lt name gt 0 Data circuit asynchronous UDI or 3 1 kHz modem The default value is 0 1 data circuit synchronous UDI or 3 1 KHz modem 4 data circuit asynchronous RDI 5 data circuit synchronous RDI lt ce gt 0 Transparent 1 Non transparent default 2 both transparent preferred 3 both non transparent preferred Example AT CBST CBST 0 4 7 12 14 17 68 70 71 75 79 84 115 116 120 121 130 134 0 1 4 5 0 3 OK AT CBST CBST 7 0 1 OK AT CBST 6 OK AT CBST CBST 6 0 1 OK H330 Module AT Command User Manual Page 68 of 304 Bs FIBOCOM 5 3 15 O Return to Online Data State This command returns the H330 from the Command mode to the Online Data mode and issues a CONNECT or CONNECT lt text gt result code After dialing or answering
134. _audio_key_tone_2 14 uta_audio_key_tone_3 15 uta_audio_key_tone_4 16 uta_audio_key_tone_5 17 aud_tone_sv_subscriber_busy 18 aud_tone_sv_congestion 19 aud_tone_sv_radio_path_ack 20 aud_tone_sv_radio_path_not_avail 21 aud_tone_sv_error_info 22 aud_tone_sv_call_waiting 23 aud_tone_info_free_tone 24 uta_audio_tone_sv_free_tone 25 uta_audio_tone_sv_connection H330 Module AT Command User Manual Page 203 of 304 Bs FIBOCOM 26 uta_audio_tone_sv_disconnect 27 uta_audio_tone_sv_device_in 28 uta_audio_tone_sv_ device_out 29 uta_audio_tone_sv_msg_full 30 uta_audio_tone_sv_ussd 31 uta_audio_tone_sv_minutte_minder 32 uta_audio_tone_sv_error_1 33 uta_audio_tone_sv_error_2 34 uta_audio_tone_sv_sms_in_call 35 uta_audio_tone_sv_broadcast_in_call 36 uta_audio_tone_sv_alarm_in_call 37 uta_audio_tone_sv_low_bat_in_call 38 uta_audio_tone_sv_power_off 39 uta_audio_tone_sv_power_on 40 uta_audio_tone_sv_single_beep 41 uta_audio_tone_sv_positive_acknowledgement 42 uta_audio_tone_sv_negative_acknowledgement 43 uta_audio_tone_sv_auto_redial 44 uta_audio_tone_sv_network_attention 45 uta_audio_tone_sv_dial_tone 46 uta_audio_tone_sv_low_bat 47 uta_audio_tone_sv_test_call lt nof_play_ti mes gt Integer indicating the amount of tone repetitions range 0 32767 Ox7FFF 0 means repeats for ever for other values a response is returned when the tone generation is finished See further DWD Audio driver interface specification
135. all forwarding is active Yes 2 Call has been forwarded Yes 3 Call is waiting Yes GSM only 4 CUG call lt index gt is present Yes 5 Outgoing calls are barred Yes 6 Incoming calls are barred Yes 7 CLIR suppression rejected Yes 8 Call has been deflected No Value Description H330 Support 0 This is a forwarded call Yes mobile terminated call setup 1 CUG call lt index gt is present mobile terminated call Yes setup 2 Call has been put on hold during a voice call Yes 3 Call has been retrieved during a voice call Yes 4 Multiparty call has been entered during a voice call Yes H330 Module AT Command User Manual Page 85 of 304 Bs FIBOCOM Value Description H330 Support 5 Call on hold has been released during a voice call not a supplementary service notification Yes Forward check supplementary service message received can be received at any time Yes Call is being connected with the remote party in an alerted state using an explicit call transfer operation during a voice call Yes Call has been connected with the other remote party using an explicit call transfer operation during a voice call or during mobile terminated call setup Number and subaddress parameters may be present lt number gt String type phone number of format defined by lt type gt lt type gt Type of address octet in integer format refer to GSM04 08 subclause 10 5 4 7 lt subaddr gt String type subad
136. and Each command must be answered by a Results code from the TA The results code reports the command status to the TE Some commands may include several Results code to send data back to the TE Some commands may initiate a mode in which when specified events are generated in the H330 Indicator messages are sent data asynchronously The indicators can be called Unsolicited results code The H330 can echo characters received from the TE commands back to the TE TE TA H330 Command Results code H330 Module AT Command User Manual Page 13 of 304 Bs FIBOCOM TE TA H330 Command Results code TE TA H330 Unsolicited results code 2 4 AT Commands Structure 2 4 1 General Symbols Used in AT Commands Description The following syntax definitions apply in this chapter Syntax Definition lt CR gt Carriage returns character specified by the value of the S3 register lt LF gt Line feed character specified by the value of the S4 register Name enclosed in angle brackets is a syntax element The brackets themselves do not appear in the command line Optional sub parameter of a command or an optional part of terminal information response enclosed in square brackets The brackets themselves do not appear in the command line When the sub parameter is not provided in the parameter type commands the new value equals its previous value In action type commands the action should be
137. arameter value is unacceptable to the MT the MT shall return an ERROR or CME ERROR response Otherwise the MT issues the intermediate result code CONNECT and enters V 250 online data state If no lt cid gt is given or if there is no matching context definition the MT will attempt to activate the context using the values for PDP type and PDP address provided by the network together with any other relevant information known to the MT The other context parameters will be set to their default values If the activation is successful data transfer may proceed H330 Module AT Command User Manual Page 222 of 304 Bs FIBOCOM Example AT CGANS CGANS 0 1 PPP M OPT PPP M HEX M RAW_IP OK Note This is not the same as if the MT issues a CGDATA or CGACT command after receiving a CRING unsolicited result code A CGDATA or CGACT does not command the MT to acknowledge the network request but rather to make a new request for context activation The network request would be ignored 13 2 10 CGAUTO Automatic Response to a Network Request for PDP Context Activation The set command disables or enables an automatic positive or negative response auto answer to the receipt of a NWinitiated Request PDP Context Activation message from the network in UMTS GPRS and a NW initiated Request EPS Bearer Activation Modification Request messages in EPS It also provides control over the use of the V 250 basic commands SO A and H for ha
138. are do not permit arbitrary characters in the dial string The lt L2P gt and lt called_address gt strings are therefore specified as lt cid gt Digit string which specifies a particular PDP context definition See CGDCONT Define PDP Context Example ATD 99 Try connecting to GPRS according to the first lt cid gt defined in CGDCONT 13 2 7 CGACT PDP Context Activate or Deactivate This command activates deactivates the specified PDP context s Command Syntax Response Action Remarks Set AT CGACT OK The Set command activates deactivates the lt state gt lt cid ai specified PDP context s When the command gt lt cid gt is completed the ME remains in V 25 NO CARRIER command state If any PDP context is already or in the requested state the state for that context remains unchanged If the requested TEME ERO SEN state for any specified context cannot be achieved an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command If the ME is not GPRS attached when the activation form of the command is executed the ME first performs a GPRS attach and them attempts to activate the specified contexts If the attach fails the ME responds with an ERROR or if extended error responses are enabled with the appropriate failure to attach error message Read AT CGACT CGACT The Read command returns the current lt cid gt lt state
139. as a result of an orderly shut down of the PDP or an error the ME enters the ITU V 25ter command state and returns the NO CARRIER final result code If lt called address gt is supported and provided the ME automatically sets up a virtual call to the specified address after the PDP context has been activated If lt L2P gt and lt cid gt are supported the CGDCONT CGQREQ and other such commands may then be used in the modem initialization AT command string to set values for PDP type APN QoS and so on If lt L2P gt is not supported or is supported but omitted the ME uses a layer 2 protocol appropriate to the PDP type If lt cid gt is not supported or is supported but omitted the ME attempts to activate the context using one of H330 Module AT Command User Manual Page 217 of 304 Bs FIBOCOM the following e Any information provided by the terminal during the PDP startup procedure For example the terminal may provide a PDP type and or PDP address to the ME e A prior knowledge for example the ME may implement only one PDP type Using the Empty PDP type No PDP address or APN is sent in this case and only one PDP context subscription record is present in the HLR for this subscriber This command may be used in both normal and modem compatibility modes Command Syntax Response Action Set ATD lt GPRS_SC gt CONNECT lt called_address gt lt L2P gt or lt cid gt ERROR The
140. as been removed from its receive buffer it places this line back in the active condition The RTS line complements the CTS line The H330 puts the CTS line in an active condition to tell the terminal that it is ready to receive the data Likewise if the H330 is unable to receive data it places the CTS line in an inactive condition Command Syntax Response Action Set AT amp K lt param gt OK or CME ERROR lt err gt Read AT amp K amp K lt param gt OK Test AT amp K amp K list of supported lt param gt s OK The following table shows the amp K parameters lt Parameter gt Description lt param gt 0 Disable all terminal H330 flow control 3 Enable CTS RTS terminal H330 flow control The default value is 0 10 1 4 IFC RTS CTS Flow Control This parameter controls the operation of the local flow control between the terminal and the H330 during the data state when V 42 error control is used or when fallback to non error control mode is specified to include buffering and flow control It accepts two numeric subparameters e lt DCE_by_DTE gt Specifies the method to be used by the terminal to control the flow of received data from H330 e lt DTE_by_DCE gt Specifies the method to be used by the H330 to control the flow of transmitted data from the terminal H330 Module AT Command User Manual Page 177 of 304 Bs FIBOCOM Command Syntax Response Action Set AT IF
141. ast entry with the new item Note3 MT may also update the User controlled PLMN selector with Access Technology list EFPLMNWAcT automatically when new networks are selected Note4 The Operator controlled PLMN selector with Access Technology EFOPLMNWAcT and HPLMN selector with Access Technology EFHPLMNwAcT can not be written since the access conditions is H330 Module AT Command User Manual Page 162 of 304 Bs FIBOCOM Administrative Note5 The command is implemented according to 3GPP TS 27 007 without acceptance in attention the lt GSM_AcT2 gt lt GSM_Compact_AcT2 gt lt UTRAN_AcT2 gt bits since the H330 device not using this bits to get the best PLMN Example AT CPOL CPOL 001 032 000 002 OK AT CPOL CPOL 000 002 42501 OK AT CPOL 0 OK AT CPOL CPOL 000 000 IL ORANGE OK AT CPOL CPOL 001 032 000 002 OK AT CPOL 1 2 42502 OK AT CPOL CPOL 000 000 IL ORANGE CPOL 001 000 IL Cellcom OK AT CPOL 1 OK AT CPOL CPOL 000 000 IL ORANGE OK 9 1 7 CBAND Change Radio Band This command allows switching from automatic band selection to selection of one or more up to four bands from the following 850 MHz 900 MHz H330 Module AT Command User Manual Page 163 of 304 Bs FIBOCOM 1800 MHz 1900 MHz Command Syntax Response Action Set AT CBAND lt band_1 gt lt OK band_2 gt lt band_3 gt lt ba or nd_4
142. atd ata commands and connect the phone enters the Online Data mode where it is able to transfer data but not to enter AT commands The ESC command transfers the phone to the Command mode able to input AT commands while preserving the Data call The O command returns the phone to the fully Online Data mode as it was before using the ESC command Note The escape character can be changed using the S2 register The time delay between consecutive escape characters is configured using the S 12 register Command Syntax Response Action Execute ATO CONNECT CME ERROR lt err gt If phone is not in Data Call NO CARRIER If connection is not successfully resumed Example ATD035684072 Calling a remote modem data call CONNECT H330 is in Data mode Escaping back to Command mode using the sequence OK AT H330 is in Command mode OK ATO Returning to Data mode CONNECT 5 3 16 CHUP Hang Up Call This command causes the H330 to hang up the current call Command Syntax Response Action Remarks Set CHUP OK The Set command hangs up the current GSM call or CME ERROR lt err gt Example atd 159867841 72 H330 Module AT Command User Manual Page 69 of 304 Bs FIBOCOM OK OK At CHUP OK NO CARRIER 5 3 17 MDC Selection of Desired Message to Be Displayed Upon Connection of a Voice Call This AT command enables you to select the desired messages
143. ation gt s lt CR gt lt LF gt CGEQMIN lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrateUL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s lisof supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s Test command returns values supported as a compound value If the MT supports several PDP types the parameter value ranges for each PDP type are returned ona separate line H330 Module AT Command User Manual Page 226 of 304 Bs FIBOCOM The following table shows th e CGEQMIN parameters lt Parameter gt Description lt cid gt A numeric parameter which specifies a particular PDP context definition see CGDCONT and CGDSCONT commands lt Traffic class gt lt Traffic class gt a numeric parameter that indicates the type of application for which the UMTS bearer service is onfirmat 0 conversational 1 streaming 2 inte
144. ax length is 255 octets sou rce_control_port Port for FTP control connection on source side the default vaule is 20 Range 0 65535 destination_control_port Port for FTP control connection on remote side Range 0 65535 source_data_port Port for FTP data connection on source side the default value is 21 Range 0 65535 Example at MIPCALL 1 UNINET create a wireless connection OK MIPCALL 10 209 215 129 AT FTPOPEN ftp adobe com anonymous ftpuser adobe com OK FTPOPEN 1 at ftpclose OK FTPCLOSE 1 open FTP connection connection success close connection close connection fails AT FTPOPEN ftp23233 adobe com anonymous ftpuser adobe com launch a connection with a non existing server OK FTPOPEN 0 AT FTPOPEN FTPOPEN 0 H330 Module AT Command open connection fails Query connection status return no connection User Manual Page 276 of 304 Bs FIBOCOM 15 3 FTPCLOSE Close Established FTP Connetion This command is used for closing the connection between the H330 module and the FTP server it only takes effect when there is no data transmission or no FTP command executed DTR interruption can close FTP connection as well Command Syntax Response Action Remarks OK Command return FTPCLOSE 1 connection success Set FTPCLOSE lt connection_status gt 6 conneckon fail Or ERROR lt error_code gt Read F
145. ccesccencossciiacobeccuvcatasessnseacsencsnseadsseensssacsevesbecstvcata sagnasiosateesascabveneavansavencetees 288 15 18 FTPGET Enter the File Download Mode uu essssssssecsssecsseecssecesseecsseecsseecsseccsseesssecssseesnecsueeesseessneeesnees 289 15 19 FTPRECV Read Data through the Port sesssscsssscsssecsseecsseecsseccssecesseecssecssseesssecssseesusecsueeesnecssneessnees 291 PEM Command esinen NRE A REEE EAE RE 293 16 1 MADIGITAL Enable Digital Audio or Disable Digital Audio sssssssssssssssssssssssssssssssssssssssseseeessessssssss 293 16 2 MAI2SY Set Digital Audio to Transmit Parameters ssssssssssssssssssssssssssssesessssssssseseseessssssssssssereeesnessssssse 294 Error Code snn EER REE RERE RREA RE RAE RAOS 296 17 1 CME FNO ccccsccescctscaes sctbiatsccbstaes sctsccuseststausccUndaeystccateatnecueauodatccundaeveccvcatbectnesueeuotatbecdntsubescscatbecunecuveeuoteebesomcsenceowee 296 17 2 MIS IED Osroena tonaren onan EEE AEE ETN 299 17 3 TPIP ENO oschis cesses d AE EEEE ENN 303 H330 Module AT Command User Manual Page 11 of 304 Bs FIBOCOM 1 Preface 1 1 Manual Scope This manual introduces the H330 AT command set and describes how software developers can use these commands to communicate with the H330 device and to create software applications that communicate with the H330 using these commands Note The integrator should read the corresponding SW release notes for the H330 version he is using to get information about
146. cept and reject Packet Domain requests CGANS may also be used Incoming circuit switched calls can be neither manually nor automatically answered 3 Modem compatibility mode Packet Domain and circuit switched calls default Automatic acceptance of both Packet Domain network requests and incoming circuit switched calls is controlled by the SO command Manual control uses the A and H commands respectively to accept and reject Packet Domain requests CGANS may also be used Circuit switched calls are handled as described elsewhere in this specification 4Turn on automatic negative response for Packet Domain only Packet Domain network requests are automatically rejected Example AT CGAUTO 0 OK AT CGAUTO 1 OK AT CGAUTO 4 OK AT CGAUTO 5 ERROR AT CGAUTO CGAUTO 0 4 OK Note When the CGAUTO 1 command is received the MT shall attempt to perform a PS attach if it is not already attached Failure will result in ERROR or if enabled CME ERROR being returned to the TE Subsequently when the MT announces a network request for PDP context activation by issuing the unsolicited result code RING or CRING to the TE this is followed by the intermediate result code CONNECT The MT then enters V 250 online data state and follows the same procedure as it would after having received a CGANS 1 with no lt L2P gt or lt cid gt values specified H330 Module AT Command User Manual Page 224 of 304 Bs FIBOCOM 13
147. cknowledgement from the TE within a predefined timeout of 15 seconds Within the timeout the H330 will not send another CMT unsolicited response to the TE before the previous one is acknowledged If the CMT is acknowledged within the timeout the new SMS is not saved in the message storage If the H330 does not receive acknowledgment after receiver a SMS within the required time CNMI parameters will NOT be reset automatically and the CMT unsolicited response will send to the TE again Example AT CNMI 1 2 OK AT CSDH 1 OK AT CMSS 142 054565034 send to myself CMSS 74 OK H330 Module AT Command User Manual Page 121 of 304 Bs FIBOCOM CMT 972544565034 04 11 04 09 48 36 08 145 4 0 0 97254120032 145 3 ABC AT CNMA OK AT CMGF 0 OK AT CMGS 18 send to myself gt 079179521201009511000c917952446505430004AA044 1424344 CMGS 70 OK CMT 23 0791795212010095040C91 7952446505430004502032115430800441 424344 7 1 11 CBM Unsolicited Response New CB Message Receipt The CBM unsolicited response is sent to the TE upon receipt of a new cell broadcast message if CNMI parameter lt bm gt is set to 2 Refer to CNMI New Message Indications to Terminal This unsolicited message displays the received CB message The displayed CBM is not saved in message storage Unsolicited Response In text mode CMGF 1 CBM lt sn gt lt mid gt lt dcs gt lt page gt lt page gt lt CR gt lt LF gt l
148. code gt file offset address already exists on the server lt Offset gt this means the server support file transfer resume The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 connected already start to download data data follows is the downloaded data H330 Module AT Command User Manual Page 288 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read FTPRETR ERROR Not supported Test FTPRETR FTPRETR lt file Return command format name gt 0 1 L O OxFFFFFFFE OK The following table shows the FTPRETR parameters lt Parameter gt Description File name A file name or a file path name string the max length is 255 octets File type File type ASCII or Binary numeric in the range of 0 1 0 ASCII 1 Binary Offset Strat upload offset address range 0 OxFFFFFFFE Example AT FTPRETR 123 TXT OK FTPRETR 2 start to download transmit data data follows are the downloaded contents love you love you FTPRETR 1 download successfully AT FTPRETR 123 TXT 0 4 start to download from the No 4 character of the offset address OK FTPRETR 2 start to download tanmismit data data follows are the downloaded contents love you I love you FTPRETR 1 download successfully 15 18 FTPGET Enter the File Download Mode By executinfg
149. command causes the H330 to push the data accumulated in its accumulating buffers into the protocol stack It is assumed that before using this command some data should exist due to previous MIPSEND commands The destination IP and destination port can be used only for UDP listen mode Command Syntax Response Action Remarks Set MIPPUS MIPPUSH Optional parameters are used only for UDP H lt Sock lt Socket_ID gt lt Status connections If the Destination IP and et_ID gt L lt gt lt accumulated_sen Destination Port are not provided by the user Destinati t_length gt a datagram is sent to the last target or the on_IP gt lt OK default target provided by the MIPOPEN Destinati command or gn Port lt accumulated_sent_length gt this parameter ERROR counts how many bytes were sent to the remote side by the H330 TCP IP stack When user open socket lt accumulated_sent_length gt initialized to zero Size of lt accumulated_sent_length gt is four octets unsigned digit 0 4294967295 lt Status gt 0 Success 1 socket is flowed off 2 there is no data in socket to send Read MIPPUS MIPPUSH H lt socket_ID gt OK Test MIPPUS MIPPUSH lt socket_ID H gt lt IP gt lt Port gt OK The following table shows the MIPPUSH parameters lt Parameter gt Description Socket_ID 1 2 3 4Number of valid socket Destination_IP IP of destination site in the forma
150. command is executed but no acknowledgment is expected or some other H330 related error occurs the final result code CMS ERROR lt err gt is returned Note AT CNMA send acknowledgment to nework Two conditions must be met AT CSMS 1 command set lt service gt to 1 AT CNMI 2 command set lt mt gt to 2 or AT CNMI 1 command set lt ds gt to 1 After the two conditions are met If the H330 does not receive acknowledgment after receiver a SMS within the required time CNMI parameters will NOT be reset automatically and the CMT or CDS unsolicited response will send to the TE again Command Syntax Response Action Remarks Set AT CNMA OK For text mode CMGF 1 or CMS ERROR lt err gt Set AT CNMA lt n gt OK For PDU mode CMGF 0 e or Note All parameters lt n gt lt length gt and DUs lt ctri Z ESColl PDU are optional CMS ERROR sid lt err gt Read The Read command for CNMA is not defined by ETSI and therefore is not supported by the H330 The H330 returns an error H330 Module AT Command User Manual Page 118 of 304 Bs FIBOCOM Command Syntax Response Action Test AT CNMA OK CNMA list of supported lt n gt s in PDU The following table shows the CNMA parameters lt Parameter gt Description lt n gt 0 command operates similarly as defined for the text mode 1 send RP ACK 2 send RP ERROR lt length gt Length of the
151. cording to the CBST Set command The H330 does not change the output but for incoming calls the phone works in automatic mode Read AT CBS CBST T lt speed gt lt name gt lt ce gt OK Test AT CBS CBST list of The Test command returns values T supported supported by the MA as compound lt speed gt s list of values supported lt name gt s list of supported lt ce gt s OK H330 Module AT Command User Manual Page 66 of 304 Bs FIBOCOM The following table shows the CBST parameters lt Parameter gt Description lt speed gt 0 Auto bauding automatic selection of the speed this setting is possible in case of 3 1 kHz modem and non transparent service 4 2400 bps V 22bis 5 2400 bps V 26ter 6 4800 bps V 32 7 9600 bps V 32 12 9600 bps V 34 14 14400 bps V 34 15 19200 bps V 34 16 28800 bps V 34 17 33600 bps V 34 39 9600 bps V 120 43 14400 bps V 120 47 19200 bps V 120 48 28800 bps V 120 49 38400 bps V 120 50 48000 bps V 120 51 56000 bps V 120 68 2400 bps V 110 or X 31 flag stuffing 70 4800 bps V 110 or X 31 flag stuffing 71 9600 bps V 110 or X 31 flag stuffing 75 14400 bps V 110 or X 31 flag stuffing 79 19200 bps V 110 or X 31 flag stuffing 80 28800 bps V 110 or X 31 flag stuffing 81 38400 bps V 110 or X 31 flag stuffing 82 48000 bps V 110 or X 31 flag stuffing 83 56000 bps V 110 or
152. css gt may include only numbers 0 9 comma and minus characters e lt mids gt 1 5 is equivalent to five channels e The dcss specified refers to all incoming messages and not only to mids specified in the same AT command H330 Module AT Command User Manual Page 140 of 304 Bs FIBOCOM Example Testing the modes supported AT CSCB CSCB 0 1 OK Reading the current mid and dcs lists AT CSCB CSCB 0 OK Adding channels 3 4 5 6 22 to mid list and languages 1 8 to dcs list AT CSCB 0 3 6 22 1 8 OK AT CSCB CSCB 0 3 6 22 1 8 OK AT CSCB 1 4 6 1 OK AT CSCB CSCB 1 4 6 1 OK H330 Module AT Command User Manual Page 141 of 304 Bs FIBOCOM 8 Access and security 8 1 1 A Repeat Last Command This command repeats the last command It is not necessary to press lt Enter gt after this command Note Only AT will not be repeated Command Syntax Response Action Repeats last command Execute A Command AT will ignore Example AT amp D amp D 2 OK A amp D 2 OK 8 1 2 AT Check AT Communication This command only returns OK Command Syntax Response Action Execute AT OK Example AT OK 8 1 3 CPIN Enter PIN for Unlocking SIM or Enter PUK for Unblocking SIM This command unlocks the SIM card when the proper SIM PIN is provided and unblocks the SIM card when the proper SIM PUK is provided
153. cular model number Command Response Action AT CGMM CGMM lt list of supported technologies gt lt model gt AT CGMM OK AT GMM GMM lt list of supported technologies gt lt model gt AT GMM OK AT FMM FMM lt list of supported technologies gt lt model gt AT FMM OK H330 Module AT Command User Manual Page 17 of 304 Bs FIBOCOM Example AT CGMM CGMM WCDMA Quad Band H330 CGMM GSM1800 GSM900 GSM 1900 GSM850 WCDMA2100 WCDMA900 WCDMA1900 WCD MA850 MODEL H330 OK 3 3 CGMR GMR FMR Request Revision These commands request the revision identification The H330 outputs a string containing the revision identification information of the software version contained within the device Command Response Action AT CGMR CGMR lt revision gt AT CGMR OK AT GMR GMR lt revision gt AT GMR OK AT FMR FMR lt revision gt AT FMR OK Example AT CGMR CGMR H330_V1H 00 08 OK 3 4 CGSN GSN Request Product Serial Number Identification This command displays the product serial number identification IMEI International Mobile Equipment Identification It can be used even when the SIM card is not inserted Command Response Action AT CGSN CGSN lt imei gt AT CGSN OK AT GSN GSN lt imei gt AT GSN OK H330 Module AT Command User Manual Page 18 of 304 Bs FIBOCOM The following table shows the CGSN GSN para
154. d lt email gt Example at cpbw 1 15986784172 129 OK at cpbr 1 CPBR 1 15986784172 129 0 OK 6 1 5 CSVM Set Voice Mail Server This command handles the selection of the number to the voice mail server The new value should also remain after power cycle Command Syntax Response Action Remarks Set CSVM lt mod OK The Set command sets the e gt lt number gt CME ERROR lt err gt number to the voice mail server lt type gt Read CSVM CSVM The Read command displays the lt mode gt lt number gt currently selected voice mail lt type gt number and status enabled or OK disabled Test CSVM CSVM list of The Test command displays the supported list of supported lt mode gt s and lt mode gt s list of lt type gt s supported lt type gt s OK H330 Module AT Command User Manual Page 101 of 304 Bs FIBOCOM The following table shows the CSVM parameters lt Parameter gt Description lt mode gt 0 Disables the voice mail number default 1 Enables the voice mail number lt number gt Voice mail number in string String can be of up to 32 characters long starting with a digit r Other allowed characters are digits 0 9 and lt type gt Address octet type 129 ISDN telephony marketing plan national international number unknown 145 ISDN telephony numbering plan international number When the dialing string includ
155. d AT CPWD CME ERROR lt err gt Test AT CPWD CPWD list of The Test command returns a list of Supported pairs which represent the available facilities and the maximum length of their passwords H330 Module AT Command User Manual Page 147 of 304 Bs FIBOCOM The following table shows the lt fac gt parameters lt fac gt Description SC SIM lock SIM UICC card SIM UICC asks password in MT power up and when this lock command issued FD SIM card or active application in the UICC GSM or USIM fixed dialling memory feature if PIN2 authentication has not been done during the current session PIN2 is required as lt passwd gt AO BAOC Bar All Outgoing Calls Ol BOIC Bar Outgoing International Calls OX BOIC exHC Bar Outgoing International Calls except to Home Country Al BAIC Bar All Incoming Calls IR BIC Roam Bar Incoming Calls when Roaming outside the home country AB All Barring services applicable only for lt mode gt 0 AG All outgoing barring services applicable only for lt mode gt 0 AC All incoming barring services applicable only for lt mode gt 0 P2 SIM PIN2 The following table shows the CPWD parameters lt Parameter gt Description lt fac gt List of supported facilities All the facility messages except for SC and P2 are sent to the network The facilities are not case sensitive Please see lt fac gt Table lt oldpwd
156. data gt If text mode CMGF 1 command execution is successful and CBM storage CMGR lt stat gt lt sn gt lt mid gt lt dcs gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt Command Syntax Response Action Remarks Set CMGR lt index If text mode CMGF 1 command execution is The Set gt successful and SMS DELIVER command CMGR reads the SMS located lt stat gt lt oa gt lt alpha gt lt scts gt lt tooa gt lt fo gt lt pid at lt index gt in gt lt dcs gt lt sca gt lt tosca gt lt lengt the H330 h gt lt CR gt lt LF gt lt data gt message _ storage and If text mode CMGF 1 command execution is f displays it H330 Module AT Command User Manual Page 129 of 304 Bs FIBOCOM If text mode CMGF 1 command execution is successful and SMS STATUS REPORT CMGR lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt s t gt If PDU mode CMGF 0 and command execution is successful CMGR lt stat gt lt alpha gt lt length gt lt CR gt lt LF gt lt pdu gt otherwise CMS ERROR lt err gt The following table shows the CMGR parameters lt Parameter gt Description lt index gt Index in storage of the message to be retrieved lt stat gt Status of message in memory PDU mode Text mode Description 0 REC UNREAD Received unread messages
157. delivered by UMTS down link traffic at a SAP As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate UL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate DL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32 kbit s would be specified as 32 e g CGEQNEG 32 refer TS 24 008 subclause 10 5 6 5 lt Delivery order gt Anumeric parameter that indicates whether the UMTS bearer shall provide in sequence SDU delivery or not 0 no 1 yes Other values are reserved lt Maximum SDU size gt Anumeric parameter that 1 2 3 indicates the maximum allowed SDU size in octets refer TS 24 008 subclause 10 5 6 5 lt SDU error ratio gt a string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 510 3 would be specified as 5
158. differences from this manual 1 2 Target Audience This manual is intended for software developers who communicate with the H330 device using the AT commands and create applications to communicate with the H330 device using the AT commands H330 Module AT Command User Manual Page 12 of 304 Bs FIBOCOM 2 Introduction to AT Commands 2 1 AT Commands Overview AT commands are sets of commands used for communication with the H330 cellular modem AT commands are comprised of assemblies of ASCII characters which start with the AT prefix except the commands A and The AT prefix is derived from the word Attention which asks the modem to pay attention to the current request command AT commands are used to request services from the H330 cellular modem such as Call services dial answer and hang up Cellular utilities send receive SMS Modem profiles Auto Answer Cellular Network queries GSM signal quality 2 2 General System Abbreviations The basic system configuration contains a modem and a terminal The H330 is the modem and may be referred to as the DCE or TA such as the phone the mobile or the radio The terminal PC or MCU may be referred to as the DTE or the TE 2 3 AT Commands Protocol The AT commands interface is basically a Modem Services upon Request Communication almost always begins from the TE side This means that any service should be requested from the TE Thus a request is called a Comm
159. dress of format defined by lt satype gt lt satype gt Type of subaddress octet in integer format refer to GSM 04 08 subclause10 5 4 8 Yes Deflected call mobile terminated call setup YES additional incoming call forwarded YES Example AT CSSN test command CSSN 0 1 0 1 OK AT CSSN 0 0 disable both options OK AT CSSN 1 0 setn value as enabled m disabled OK AT CSSN CSSN 1 0 display the current n amp m values OK CSSI 1 displayed after mobile originated call setup of call forward and n enable CSSU 2 displayed when a call has been placed on hold during the call using the CHLD AT command and m enable H330 Module AT Command User Manual Page 86 of 304 Bs FIBOCOM 5 6 2 CUSD Unstructured Supplementary Service Data This command allows control of Unstructured Supplementary Service Data US SD according to GSM 02 90 Both network and mobile initiated operations are supported Parameter lt n gt is used to disable enable the presentation of an unsolicited result code USSD response from the network or network initiated operation CUSD lt m gt lt str gt lt dcs gt to the TE In addition value lt n gt 2 is used to cancel an ongoing USSD session When lt str gt is given a mobile initiated USSD string or a response USSD string to a network initiated operation is sent to the network The response USSD string from the network is returned
160. dvance is defined for serving cell only This value will be reported only in Dedicated and TBF modes Valid value range is from 0 to 63 Example AT MCI MCI 15 0 OK AT MCl 1 OK MCI 712 33 93 AT MCl 1 0 OK MCI 712 33 92 AT MCl 1 1 OK MCI 712 33 93 AT MCI 2 1 OK MCI 712 33 93 97 255 110 110 255 110 112 255 110 AT MCIl 2 0 H330 Module AT Command User Manual Page 172 of 304 Bs FIBOCOM OK MCI 712 33 93 97 255 110 110 255 110 112 255 110 AT MCl MCI 1 15 0 1 OK 9 1 12 GTRAT Selection of Radio Access Technology This command forces the selection of the Radio Access Technology RAT in the protocol stack On a later network registration COPS CGATT this RAT is used This command is available for phones supporting Dual Mode In case of GSM UMTS DualMode is selected additionally a preferred RAT can be configured which is stored in NVRAM selecting which RAT shall be attached first Note Dual mode means GSM and UMTS Access Technology will be active and full InterRAT measurements and handovers are provided e Set command is used to set RAT and proffered RAT value used for further network registration at cops 0 e Read command returns the previously set of lt Act gt and lt PreferredAct gt values e Test command returns the range of supported lt Act gt and lt PreferredAct gt values Command Syntax Response Action Re
161. e it is possible to control access to the GPRS using existing modem compatible commands This modem compatible mode of operation is described below 13 2 1 CGCLASS GPRS Mobile Station Class This command is used to set the H330 to operate according to the specified GPRS mobile class If the requested class is not supported an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command H330 Module AT Command User Manual Page 209 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set AT OK Set command is used to set the MT CGCLASS lt cla sr to operate according the specified ss gt l mode of operation CME ERROR lt err gt Read AT CGCLASS CGCLASS lt class gt The Read command returns the OK current GPRS mobile class Test AT CGCLASS CGCLASS list of The Test command is used for supported lt class gt s requesting information on the OK supported GPRS mobile classes Note Issuing GPRS actions over a poor quality connection may cause protocol errors and harm data validity To prevent these problems H330 is equipped with a protection mechanism that confirms GPRS signal strength before issuing GPRS network related commands The following table shows the CGCLASS parameters lt Parameter gt Description lt class gt String parameter that indicates the GPRS mobile class A class A only supported if UMTS_SUPPORT is enabled B mea
162. e data portion of the IP datagram is an ICMP lt type gt field The value of this field determines the format of the remaining data The lt type gt and lt code gt fields jointly define ICMP message type For example a case when an Echo Request message encapsulated in IP datagram to be forwarded by a gateway has exceeded TTL equal zero In this case the gateway must discard the datagram and may return an ICMP Time Exceeded message Example AT MIPCALL 1 internet OK MIPCALL 10 170 4 111 AT MPING 1 10 170 4 112 Ping remote computer using default parameters OK MPING 10 170 4 112 0 0 400 Echo Reply message received RTT is 400 ms MPING 10 170 4 112 0 0 420 MPING 10 170 4 112 0 0 440 MPING 10 170 4 112 0 0 410 Ping request execution is completed Four Echo Request messages were sent and four Echo Reply messages were received Average RTT is 417 milliseconds MPINGSTAT 0 10 170 4 112 4 4 417 14 15 MPINGSTAT Status Update for MPING Execution This is the unsolicited response that the H330 sends to the terminal to inform of ping execution status update and provides summary statistics of ping request when ping request execution is completed Command Syntax Response Action Remarks Unsolicited MPINGSTAT The unsolicited response that the H330 sends to Response lt status gt lt Destinatio the terminal to inform it with ping execution n_IP gt lt SentMessages status update This
163. e data transmitted by control connection If a local path is specified the server will response by a file or properties list related with the specified item If no parameter is speicifed the sever will return the general status information of this FTP process which include the value and connection status of all current transmission parameters Command Syntax Response Action Remarks Set FTPSTAT lt file OK FTPSTAT Parameter is optional can be a file directory name gt lt result gt lt status gt or name or a file path name The ERROR lt error_code gt command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 data follows Read FTPSTAT ERROR Not supported Test FTPSTAT FTPSTAT Return command format lt file directory name gt OK The following table shows the FTPSTAT parameter lt Parameter gt Description File directory name A file name or a file path name string the max length is 255 octets Example FTPLIST 1 AT FTPstat usr OK FTPSTAT 2 213 Status follows H330 Module AT Command User Manual Page 285 of 304 Bs FIBOCOM FTPSTAT 2 FTPSTAT 1 AT FTPstat OK drwxr x x 5 ftp ftp FTPSTAT 2 213 End of status FTPSTAT 2 211 FTP server status Connected to 221 179 37 21 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FTPSTAT 2 FT
164. e format AAA BBB CCC DDD The range of each octet is 0 255 Value can be written in 1 2 or 3 digits Host name The host name convention should meet the rules as describe in RFC 1035 section 2 3 Conventions Syntax is not validated except the maximum length 255 characters Remote_Port Port of remote site Port range 1 65535 decimal digits for outgoing connection Port 0 for incoming connection Protocol Type of protocol stack OTCP 1 UDP State 0 Inactive 1 Active H330 Module AT Command User Manual Page 248 of 304 Bs FIBOCOM Note It s recommended not to use port numbers below 1024 those numbers are reserved for OS use Example AT MIPOPEN 1 1200 123 245 213 012 1234 0 Opening socket 1 using TCP protocol from port 1200 targeting 123 245 213 012 port 1234 AT MIPOPEN 2 1300 123 133 074 192 1242 1 Opening socket 2 using UDP protocol from port 1300 targeting 123 133 074 192 port 1242 AT MIPOPEN 1 1222 123 245 213 012 1234 0 Opening socket 1 using TCP protocol from port 1222 targeting 123 245 213 012 port 1234 AT MIPOPEN Terminal checking the free sockets MIPOPEN 3 4 OK AT MIPOPEN 1 0 WWW GOOGLE COM 80 0 TCP OK MIPOPEN 1 1 AT MIPOPEN 2 0 www google com 80 1 UDP OK MIPOPEN 2 1 Listen socket over TCP AT MIPOPEN 1 1100 0 0 0 0 0 0 Listens to any port at any IP OK MIPOPEN 1 1 122 221 32 64 1200 Remote side connected to the listen soc
165. e invalid user s responsibility to set date time and time zone by CCLK Set Command Note See Execute Command for how to enable back network update time Test CCLK CCLK list of The Test command returns valid parameters supported for the CCLK Set command lt time gt s OK The following table shows the CCLK parameters lt Parameter gt Description lt time gt ASCII string of format yy MM dd hh mm ss zz or yy MM dd hh mm ss or yy MM dd hh mm yy 2 digit year 2000 2069 MM 2 digit month 01 12 dd 2 digit day of month 00 31 hh 2 digit hour 00 23 mm 2 digit minute 00 59 ss 2 digit seconds 00 59 zz optional time zone offset from GMT in quarter hours 47 48 If this value is not specified the time zone offset will be 0 H330 Module AT Command User Manual Page 103 of 304 Bs FIBOCOM Example AT CCLK CCLK 88 12 31 23 59 59 47 48 OK AT CCLK 01 01 01 01 01 01 08 OK AT CCLK CCLK 01 01 01 01 01 01 08 OK AT CCLK 02 02 02 02 02 02 OK Power cycling AT CCLK CCLK 02 02 02 02 02 02 00 OK H330 Module AT Command User Manual Page 104 of 304 Bs FIBOCOM 7 SMS 7 1 SMS Commands H330 supports SMS PDU and SMS TEXT mode according to ETSI specifications 3GPP TS 27 005 amp 3GPP TS 03 40 23 0400 7 1 1 CSMS Select Message Service This command handles the selection of the messaging serv
166. e path active mic speaker and alert speaker will have these saved gain levels Note The SMS MT volume is adjusted using the MAVOL command with type ring The RING value is related to the SMS alert the MT call and so on H330 Module AT Command User Manual Page 200 of 304 Bs FIBOCOM accessories supported features combinations supported volume levels Command Syntax Response Action Remarks Set MAVOL lt acc OK The Set command sets the volume y gt lt feature gt lt ae level lt n gt to a certain lt feature gt vol gt through a certain lt accy gt CME ERROR lt err gt Read MAVOL Current path volume The Read command returns the MAVOL volume level of all the features in the current active accessories lt accy gt lt feature1 gt vol gt MAVOL lt accy gt lt feature2 gt vol gt MAVOL lt accy gt lt feature4 gt vol gt MAVOL lt accy gt lt feature8 gt vol gt OK Test MAVOL MAVOL supported Test command returns the supported range of volume levels accessories and features The following table shows the MAVOL parameters lt Parameter gt Description lt accy gt 1 1 channel SPK SPK 1 3 2 2 4 channel AUXO AUXO 3 1and2 6 lt feature gt 1 Voice 1 7 2 Tone 3 1and2 4 Midi 5 1and 4 6 2and 4 7 1 and 2 and 4 lt vol gt Volume level 0 7 H330 Module AT Command User Manual Page 201 of 304 Bs
167. e terminal 1 unavailable MT does not allow commands from TA TE 2 Unknown The H330 is not guaranteed to respond to instructions 3 Ringing MT calls The H330 is ready for commands from the terminal but the ringer is active 4 Call in progress The H330 is ready for commands from the terminal but a call is in progress 5 asleep MT is unable to process commands from TA TE because it is in a low functionality state H330 Module AT Command User Manual Page 72 of 304 Bs FIBOCOM Example AT CPAS CPAS 0 OK AT CPAS CPAS 0 5 OK AT CPAS CPAS 4 OK AT CPAS Voice call active state CPAS 4 OK 5 4 2 CLCC List Current Calls This command displays a list of all current H330 calls and their statuses and also enables disables the unsolicited indication of the call list If no calls are received no information response is sent to the terminal If the command succeeds but no calls are available no information response is sent to the terminal The maximum number of simultaneous multiparty calls is 5 1 5 in active group and 1 on hold Command Syntax Response Action Remarks Set AT CLCC OK The Set command lt state gt a enables disables unsolicited indications CME ERROR lt err gt Execute AT CLCC CLCC lt idx gt lt dir gt lt call state gt The Execute command lt mode gt lt mpty gt lt number gt lt typ enables the receiving of e gt lt CR gt lt LF gt data about cur
168. e_name_to gt indicates the file after named The OK command execution result return to the user as an_ unsolicited response 0 operation fails 1 operation success Read FTPREN ERROR Not supported Test FTPREN FTPREN lt file name Return command format from gt lt file name to gt OK The following table shows the FTPREN parameters lt Parameter gt Description File name from Old name of file to be renamed String max length is 255 octets File name to New name of file to be renamed String max length is 255 octets Example AT FTPREN 1234 txt 12345 txt FTPINFO RNFR 1234 txt OK FTPINFO 350 Ready for RNTO FTPINFO RNTO 12345 txt FTPINFO 250 Rename successful H330 Module AT Command User Manual Page 283 of 304 Bs FIBOCOM FTPREN 1 15 12 FTPLIST Request List This command makes the server send a list to the client Note If path name specified a directory or other file groups the server will send a list of the files in the specified directory If the path name specified a file then the server should send the current information of this file No parameter means current working directory or default ERROR lt error_code gt Command Syntax Response Action Remarks Set FTPLIST OK FTPLIST lt result gt Parameter consists of the lt file directory lt list of directory files gt file directory name as well as the name gt
169. ececouessennsstetavecennuaustines 77 5 5 2 CACM Accumulated Call Meter os esssesscssssecsssscseecssecsssscessscsssseesssecssecensesssecessneecsseccssecssseesseesusesesnes 79 5 5 3 CAMM Accumulated Call Meter Maximum sssssecsssscsssecsssecsseecsseecsssecsseecsseessseccsseecsseecsseesseeesees 80 5 5 4 CPUC Price per Unit and Currency Table 0 essssescsssscsseecsseccsseecssecesseecsseccsseccsseecsseecssecssseesseeesses 82 5 5 5 CR Service Reporting Control nn essescssescssescssescsseccssecesseccssecssscessscesuecesseecsueccsseccsseecsseessseesseeesseessees 83 5 6 Supplementary Services eeccsescssssccseecsseecsseecsseccsseecsseecsseccsseccsseecsseesssecsssesueeesueecsueecsueeesuecesseessneessseecsseessseess 84 5 6 1 CSSN Supplementary Service Notifications sseccssssccssescssssecessecccsseccssnsecesuseccsnsecessseeessneeeses 84 5 6 2 CUSD Unstructured Supplementary Service Data ssescsssecssescsseecssescseccsseecseecsseesseecsneesees 87 5 6 3 COLP Connected Line Identification Presentation sseccssseccsssescsssescssnescesssecessseecesneesssneesees 91 6 Phone Book and COCK ceeesssssssssscsssecsseecsseccsseccsseccsseccsneccsseccssecsuseesnsccsusecsuecesuecesseecsnecessescssecsuseessseesuseesueeesueeesseeesuecesneeessees 93 6 1 Directory Access Commands Phone BOOK sesssescssccseeccseecneeesseeesssecsseecsneecsseccsseecsseessseccsseesseesneeessees 93 6 1 1 CPBS Select Phone Book M MOry ssscsssscssescs
170. ecessescesneeeeeee 18 3 5 CSCS Select Terminal Character Set sssssssscsssecsecsseecsseecsssecsssecsuescsssecsseccsseessseessseessscessseesucessueeesneeess 19 3 6 POM REQUEST IMIS I ccascsosesascessezosesssezesectsazoseensazeseesdasosessdedodgehdatosechdad0dgredet0aguodatoascabategsoaatedgvodatoassodadesecctacodees attic 20 3 7 CFSN Read Factory Serial NUMDELM esssescssescsseecsseccsseecssccssseesssecssseessscesueesueecssecesseecsuecesseesssecsaseessseess 21 3 8 Request Identification INfOrMation esssssscsssseccssesccssscessssecssuseccsnsecessecesssecesssecessuesessnsecesnsecessseeeesneesees 21 3 9 CNUM Request MSISDN S eessssscsssscssescsssecssescsseccsseccsseccsseccssecsssessusecsuseessssesucecsueeesuecesseecsneesssecesnecsuseessseess 22 3 10 CLAC List of All Available AT Commands u ssssssssssscssssscssssscessseccssseecesnecessusceesssecessseeessuecssnsecesnseeesaneeeeey 23 4 Modem Control and Status cessescsssscssscsescseccseesseecsssecssecsusecsueecsuecesseesssecsssecssssesuseesuseesueeessesesneecasescanecsaseessseesueeessees 24 4 1 Modem Register COMMANAS sssssescsescseccsteccseecsseecsseecsseccssecesseccsneccsseecssecsssecssscesucesseecsuesesseesanecesseessseess 24 4 1 1 V7 H330 Response Format esnsnsririiriiniri nanana EEEE 24 4 1 2 Q Result Code SuUppresSsSiOn ssssssssssssssssssssssecceesssssssssscecccesssssssssteeeeeesesssssssseeeeeessssssssteeeeeeessssssssteeeeeesesss 25 4 1 3 E Command
171. ecssseesusecsuseesueecsueecssesestecsses 142 8 1 3 CPIN Enter PIN for Unlocking SIM or Enter PUK for Unblocking SIM ssssccsssescesseeceesees 142 8 1 4 TPIN Query Number of Remaining SIM PIN PUK Entering Attermpts ssccsssssccsseccssees 146 8 1 5 CPWD Change Password u ecssssscsssscsssecsseecsssccsseccsseecsseccssecssseessscessseesueeesueessneccsseecsseesuseessseesnseesneeess 147 8 1 6 CLCK Facility LOCK seesssesssssecssessnsecsnsccsseccsseccsseccsseecssecssseessseesuseesusessuceesnecssneccsseessseesnsecssseesneesneeess 149 INGE WOK 5 ctsccsccsiccessscinccasssesgtacseccotazacecshanuacubsacesaveacnaussaupecebasabusenasabsassstatscovs tabs gusndabs oupacets azbdeen ussaneacobsaomsearsaasbassuovenceleasbantebiens 152 9 1 Network Commands essssscssescssescsseecsseecsseecsseccsseesssecsnscesueesseccsneccsnecesseessseessseesuseesuscesuecsuecesneessseceaseesnseesses 152 9 1 1 CSQ Signal Strength csesssssscsseccsseecsseesssecssseesuscesssecsucesseecsnecesseecsseccssecsssecsssecssseesnseesueeesneeesneesse 152 9 1 2 F CRLP Radio Link Protocol ou esssessssssecsseesseccsseessscesssccsseecsusccsseccsneecsseessseecssecssseesnsseceusesueeesneeesseeess 153 9 1 3 CREG Network Registration Status ou esssescsssecsssecscecssecsseessseecsucecsseccsneecsseccsseessseessecsseesseeeess 154 9 1 4 CGREG GPRS Network Registration sssssssscsseccsseccsseecsseesseessecesseecsueccsneecsseecsseessseesseesueesneeess 155 9 1 5 COPS
172. ectvece sects ocaueceveccesebeccueeebecebes 126 7 14 15 CMGR Rad MO SSage sccsccaccss casicoss ccessdssabsoveacesaccducatascnnasesossacouscabuasansabeeveecsvecstncetasessaseasssvesterabageencateds 129 7 1 16 CMSS Send Message from Storage ssssccssssscsssssccsssscssneecesssecessneeessnseessnsessnscescssecessueeeesnseessnaeses 132 7 1 17 CMGW Write Message to MeQMoy uu sssssssecsescseecsscsecssscssscssssessecssecsssessscsecsnsceseecsseesseessseareeseessee 134 7 1 18 CMGD Delete Message sscsssscssssccsesccnesccneescneescssesssecessscsssecssssesssecenssesneseenesssneesenesesseeseneeseneesssees 136 7 1 19 CGSMS Select Service for MO SMS Messages ecsssssscssssscsssssssssssssssnseccsssesessuescssusscssneeseaneesssues 137 7 1 20 CMGS Send SMS to Network esssescsssecsssecssssesseecsssecsseecsusecsseecsseecsseessnecessecssseessseesssecsueesneeesueeessess 138 7 1 21 CSCB Cell Broadcast Messages essssscsssscssseesseecsseecsseecssseesseecsuecesseccssecesseesssecssseessseessseesseeesuseessees 139 8 Access and SECUIITY esssescsseccsseccsseccsseccsseccssecsssccsuscesssccsueecsseccsuecesseessnecssseessseesusessusecsuseesueecsueeesseecsuecsssesssseesuseesueesuseesuees 142 8 1 1 A Repeat Last Command sssssssssssseccccessssssssseeeceeesssssssseteeecesessssssssteececeesssssssstceeeeeessssssssseeeeeeessssssssse 142 8 1 2 AT Check AT COMMUNICATION ou eesssescsseecsseecsseccsseccssecesseccsseccsseccssecsssecsss
173. ell selection is forced to an operator lt oper gt given L lt oper gt L lt in format lt format gt If the selected operator is AcT gt II not available no other operator is selected except when the lt mode gt is set to 4 lt mode gt 2 forces an attempt to deregister from H330 Module AT Command User Manual Page 157 of 304 Bs FIBOCOM the network lt mode gt 3 sets the operator format to all further Read commands COPS as well The selected mode applies to future network registrations for example once you deregister from the network the H330 remains unregistered until you select lt mode gt 0 lt mode gt 1 or lt mode gt 4 Read AT COPS COPS lt mode gt lt format gt lt oper gt lt AcT gt OK Or CME ERROR lt err gt The Read command returns the current mode and the currently selected operator Test AT COPS COPS list of supported lt stat gt long alpha numeric lt oper gt short alphanumeric lt op er gt numeric lt oper gt Llist of supported lt mode gt s list of supported lt forma t gt s OK The Test command returns a list of quadruplets each representing an operator present in the network A quadruplet consists of an integer indicating the availability of the operator lt stat gt long and short alphanumeric format of the name of the operator and numeric format representation of the operator If any of the format
174. enabled gt or CBM lt sn gt lt mid gt lt dcs gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt Class 3 CBMs are routed directly to TE using unsolicited result codes defined in lt bm gt 2 If CBM storage is supported messages of other classes result in indication as defined in lt bm gt 1 lt ds gt 0 No SMS STATUS REPORT indications are routed to the terminal default SMS STATUS REPORT is routed directly to the terminal If SMS STATUS REPORT is stored in the H330 the memory locationindication is routed to the terminal using the unsolicited result code CDSI lt mem gt lt index gt lt bfr gt 0 TA buffer of unsolicited result codes defined within this command is flushed to the TE when lt mode gt 1 3 is entered OK response shall be given before flushing the codes TA buffer of unsolicited result codes defined within this command is cleared when lt mode gt 1 3 is entered Example AT CNMI H330 Module AT Command User Manual Page 116 of 304 Bs FIBOCOM CNMI 0 2 0 3 O 3 O 2 0 1 OK AT CNMI CNMI 0 0 0 0 OK AT CNMI 2 1 OK AT CMSS 142 0544565034 send to myself CMSS 72 OK CMTI SM 15 AT CNMI 1 2 OK AT CSDH 1 OK AT CMSS 142 054565034 send to myself CMSS 73 OK CMT 972544565034 04 11 04 09 48 36 08 145 4 0 0 97254120032 145 3 ABC AT CSMP 49 167 Set first octet to status report See s
175. ends to configure supported GPIO pins and gets value from input pin H330 support 11 GPIO pins All these pins can be set to output and input mode The default configuration is input but it s better to set direction before use The high voltage level is 1 8V Command Syntax Response Action Remarks Set AT GPIO lt pin gt lt OK Used to set direction and direct gt lt value gt output value Or CME ERROR lt err gt Read AT GPIO GPIO Return all the pin state f here lt pin gt lt direct gt lt value gt OK Or ERROR Test AT GPIO GPIO lt pin gt lt direct gt lt value gt Return supported values OK or ERROR The following table shows the GPIO parameters lt Parameter gt Description lt pin gt 23 52 53 73 74 75 76 89 106 107 108 The value is pin number on module lt direct gt 0 Input 1 Output 2 Query output value of the single pin lt value gt 0 Low level 1 High level H330 Module AT Command User Manual Page 190 of 304 Bs FIBOCOM Example AT GPIO 23 1 1 OK AT GPIO GPIO 23 0 1 52 0 1 sleet Leave out some value here 107 0 0 108 0 0 OK AT GPIO 23 2 GPIO 1 OK AT GPIO GPIO 23 52 53 73 74 75 76 89 106 107 108 0 2 0 1 OK 10 3 UART2 configuration There are two UARTs in H330 module One is primary called UART1 and the other is assistanted called UART2 UART2 have two type of wor
176. eout gt OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK Send data at fixed length All characters can be send at this method Command Syntax Response Action Remarks Set MIPSEND lt Socket_ D gt lt Data_ en gt MIPPUSH lt Socket_ID gt lt Status gt lt pus hed data length gt MIPSEND lt Socket_ID gt lt Status gt lt Fre eSize gt or ERROR After command received H330 will respond gt lt CR gt lt LF gt Send any data in HEX The data buffer range is 0 lt data_len lt 2048 bytes When H330 receive the corresponding length data the data will be push automatic and returns to regular AT command mode Notes The redundant data will be lost H330 Module AT Command User Manual Page 256 of 304 Bs FIBOCOM Notes If there is any data in the buffer sent by previous mipsend H330 will reply ERROR to TE Example Opening socket 2 already AT MIPSEND 2 10 gt 0123456789abc abc lost OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK 14 7 GTSET Set receive data mode Command Syntax Response Action Set GTSET lt ParamName gt lt value gt lt value1 gt OK or ERROR The following table shows the GTSET parameters related HEX mode lt Parameter gt Description lt ParamName gt SENDTIME Set the auto push timeout See description of lt value gt below lt value gt 1 30 seconds The defaul
177. ep Mod Command Sinnsir eesi oseon EENE E RE e 39 4 2 1 S24 Set Number of Seconds Delay Before H330 Enters Sleep MOdEe sssssccsseccssescesseeeeeees 39 4 3 Error Handling Gomimiaind sisi ccssccsscccsceiiceusccuucces chascascnss cas atebebusssnasea sencnbeecabcesensonnavensosectebabes esncscanssncouecebveccodeey 40 4 3 1 CMEE Report Mobile Equipment Error sesssssscssssccssscsseecsssecsseecsseecsssecssecesneccsseecsseecsseecsseesseeesses 40 4 3 2 CEER Extended Error Reportase eoriet oeiee oi e Ee i R 42 3 Cea LG OMEN ae scccecccesceczscecwcazececccutcrascess des E EE A AA E 43 5 1 Managing a CSD Data Call esssssssssscssscssescsssccsseecsueecsseccsseccsseecssecsssecssseessseesnsecsuseesueeesueeesneecsueeeanessanees 43 5 1 1 STN SMD ea NAG ee EE EEEE EEEE 43 5 1 2 Switching From Data Mode to Command Mode essssessseccseeecsseesseessecsseeesseecsseeessesesneeesseessnees 43 5 1 3 Hanging UD is teecssensscscsescescesaucesscstsceescstucveseetucvssestuveseeduccbatetacenssetecetaeeteeussetecensetoccaseetsavsbuedoecusesteucevestoartrestene 44 5 2 Receiving a Data Call nn sssescsssscssescsseccssescsseccssecsssecsssecsssscsuseesseecsueccsseccsseecsseesssecsssessuseesuseesueecsueceaseecsneesaseess 44 5 3 Call Control AT COMMANAS essssescsseecsseecsseecsseccsseecsseccsseccsseccsscesssecsusecsuseesuscesusessucesueessuecesneesssecesneessseesseeess 44 5 3 1 D Dial COMMANGA D 44 5 3 2 D gt Direct Dialing from Phone BOokS sssssscss
178. er lt Parameter gt Description Directory name octets The name of file directory need to be created string the max length is 255 Example AT FTPMKD 1234 OK FTPMKD 15 7 FTPRMD Remove Directory 1 This command is used for removing a specified directory in a path name for absolute path name or subdirectory of current working directory for relative path name Command Syntax Response Action Remarks Set FTPRMD lt di OK FTPRMD lt directory_name gt parameter consistes rectory_name lt result gt Or ERROR ofdirectory path or subdirectory of current gt lt error_code gt path The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPRMD ERROR Not supported Test FTPRMD FTPRMD Returns command format lt directory name gt OK The following table shows the FTPRMD parameter lt Parameter gt Description Directory name The name of file directory need to be removed string the max length is 255 octets Example AT FTPRMD 1234 FTPINFO OK RMD 1234 FTPINFO 250 RMD command successful H330 Module AT Command User Manual Page 280 of 304 Bs FIBOCOM FTPRMD 1 15 8 FTPPWD Print Working Directory This command is used for requesting the server to return name of current working directory Command Syntax Response Action Remarks Set FT
179. er OK The set command identifier gt lt evaluation ERROR Spee lee PaCkER RNE that is to be added to the precedence index gt lt source i address and subnet mask gt TET stored inthe Mt and lt protocol number ipv4 ue for PAE EOE next header ipv6 gt identified by the local eer context identification lt destination port range gt parameter lt cid gt lt source port range gt lt ipsec security parameter index spi gt L lt type of service tos ipv4 and mask traffic class ipv 6 and mask gt lt flow label ipv6 gt JIT Read CGTFT CGTFT lt cid gt lt packet The read command returns the current settings for all Packet Filters for each defined context H330 Module AT Command User Manual Page 242 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test CGTFT CGTFT lt PDP_type gt list of supported lt packet filter identifier gt s list of supported lt evaluation precedence index gt s list of supported lt source address and subnet mask gt s list of supported lt protocol number ipv4 next header ipv6 gt s list of supported lt destination port range gt s list of supported lt source port range gt s list of supported lt ipsec security parameter index spi gt s list of supported lt type of service tos ipv4 and mask traffic class ipv 6 and mask gt s list of supported lt flow label ipv6 gt
180. eration H330 Module AT Command User Manual Page 155 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read AT CGREG CGREG The Read command returns the lt n gt lt stat gt lt lac gt lt ci gt status of the result code presentation L lt AcT gt lt rac gt and shows whether the network has OK currently indicated the GPRS registration of the H330 Location information elements lt lac gt and lt ci gt are returned only when lt n gt 2 and the H330 is registered in the network Test AT CGREG CGREG list of The Test command displays the supported lt n gt s supported values of lt n gt OK The following table shows the CGREG parameters lt Parameter gt Description lt n gt 0 Disables the network registration unsolicited result code 1 Enables the network registration unsolicited result code CGREG lt stat gt 2 Enables the network registration and location information in unsolicited result code and Read command CGREG lt stat gt lt lac gt lt ci gt The default value is 0 lt stat gt 0 Not registered and the ME is not currently searching for a new operator to register 1 Registered home network 2 Not registered but the ME is currently searching for a new operator to register 3 Registration denied 4 Unknown 5 Registered roaming lt lac gt Two byte location area code in hexadecimal format lt ci gt Four byte cell ID in hexadecima
181. es charge for MO or and MT calls There are two states in which the command can be activated in IDLE state returns the last call cost A voice data state returns the accumulated cost including the current call CAOC lt ccm gt or CME ERROR lt err gt Command Syntax Response Action Remarks Set CAOC lt mode CAOC lt ccm gt The Set command returns the CCM gt OK value from the H330 or activates deactivates unsolicited or reports CME ERROR lt err gt Read CAOC CAOC lt mode gt The Read command returns the CAOC OK current CAOC mode or H330 Module AT Command User Manual Page 77 of 304 Bs FIBOCOM Command Syntax Response Action Test CAOC CAOC list of supported lt mode gt s OK The Test command returns the supported mode values The following table shows the CAOC parameters lt Parameter gt Description lt mode gt 0 Queries the CCM value 1 Deactivates unsolicited reporting of the CCM value 2 Activates unsolicited reporting of the CCM value Note lt CCM gt String type value representing three bytes of the current call meter value in hexadecimal format for example 00001E indicates decimal value 30 Example Example with prepaid SIM card with 56700 00L prepaid before the test AT OK AT CAOC 2 OK atd 97254565190 OK OK CCCM 000000 CCCM 000006 AT CAOC CAOC
182. es the international access code character the default is 145 Otherwise the default lt type gt is 129 Note If lt mode gt is set to 0 lt number gt and lt type gt are ignored If lt mode gt is set to 1 lt number gt is mandatory Example AT CSVM CSVM 0 1 129 145 OK AT CSVM 1 97255512356 145 OK AT CSVM CSVM 1 97255512356 145 OK 6 2 System Date and Time Access Commands 6 2 1 CCLK Read Set System Date and Time This command reads and sets the H330 current date time and time zone Command Syntax Response Action Remarks Set CCLK lt time gt OK The Set command sets the date time and aie time zone of the system clock CME ERROR Note Set Command sets user defined eps system clock values and saves them in the NVM memory These saved values are kept after power cycle as well H330 Module AT Command User Manual Page 102 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read CCLK CCLK lt time gt The Read command returns the current OK date time and time zone setting By default lt time gt will represent the or CME ERROR network updated time lt err gt If the user has used the Set command once then lt time gt will represent the Set command setting Note If network operator does not support System Clock Update Message the initial date time and time zone displayed by CCLK Read Command could b
183. essssssssesee eses 193 11 2 2 CLVL Loudspeaker VOlUMe sssssssssssssessssssssssssesesessesssssssseeeeeessssssssssteeeessnusssseteneeeesensssssestrereesssss 193 11 2 3 CMUT Mute Unmute Microphone and Speaker Path ssssssssssssssssssssssssssseseesessssssssesereesssss 194 11 2 4 S94 Sidetone Effect seesscsssssccsssscccssseccsseccssnecesnsccesssceessueessuseessnsecessseecssnscessusceesnseeessucessncessueessnesees 195 11 25 596 Echo Cancelling sacsccs csccce tase cazeducccteadetsencesatasscadetecwendatlesdelebvaseedsbecess avssdaletvsseetateonvedsttcstebeccaseebateane 196 11 2 6 CALM Alert Sound Mode ecsesssssssssescsssccssescsssccsseccssecssseccssecsssecssseesuscesseecsueecsueecsnecessesesnecenseessseess 196 H330 Module AT Command User Manual Page 8 of 304 Bs FIBOCOM 1a EV TID TOM DUP ator icccesccsccescaes cscs cate nunnana nR OREN NON RONNE 197 11 2 8 VTS Command Specific Tone Duration ssssssccsssscssseecesssceesssecessseceesnecessnseesssseecesnecessneeeesnseees 197 11 2 9 AVTA Set Play DTMF type ascsssccsiccseccessscssaicassncesscceveclassesuscacesscncsecovssensassessocabeantcata en i n e ER 198 11 2 10 EMAPATH Audio Path evictacssscctvccasasavcsassctsasscectnssncestecchavsearaussedansecechvesanaibveraugsensubcccdnssecncbevchoissecancccanaaacs 199 11 2 11 FMAVOL Volume Setting sssessosssscsssccssesssscsssscesssesnsseenessensscenesecsceesecssssesssecssssessseeensssenesseneeeeneeess 200 11 2
184. et UDP or TCP in Online Data Mode eesssssssssscseecsecsseecsseecsneeessees 272 14 18 MIPXOFF Flow Control XOff e sssssscsssescssssscessesccsnsecesnsececssecccssscessusceesnsceesasecessucessuscessnsecesnseeeenseeeesnsesees 274 14 19 MIPXON Flow Control XON sseesssessssecsseccssccsscccssecesseecsseccsseccssecsssecsssecsuseesuscssuecesueecsuecesneecssecssseessseesses 274 Ee alna ae e E E E E E E EE E EEEE 275 15 1 FTP INtrOCductiOn ssessssescsssscsseesssescsssecsseccsseccsseccssecssseessscesuscssueccsueecsneccsseessseesssecsuseesuseesuscesseeesneesssecsasecsnseesies 275 15 2 FTPOPEN Open a FTP Connection With FTP Server sesssescsssscsssscssecesseecsseecsseecsseccsseesssecssseessseesees 275 15 3 FTPCLOSE Close Established FTP Connetion sesssssscsssscssesssssecsseeesseccsssecsssecsneccsseccsseesssecssseessseesses 277 15 4 FTPINFO FTP Unsolicited Indication Enable Disable uu essssssssssscsssecsseccsseecsseccsseccssecssseessseesees 277 15 5 FTPCWD Change Working DirectOry seccsssccsseecseecsseccseecseesseesssesuecesusecsusecsseccsseccsseesssecssseessseesees 279 15 6 FFTPMKD Make Dire ctory sssescsssscsssecsseecssescsssecsseecsseccsseccsseccsseesssessnseesusessuscesueecsueecsneccsseccsseessseessseesnsessses 279 15 7 FEETPRMD REMOVE Directory sssccssccssscssscssecescossecssecssecsseassecsseassadsseavseassecssecsseaseacuseaseadbseavseassecsseassecdvecusoauseenes 280 15 8 FTPPWD Print Working D
185. et automatically and the CDS unsolicited response will send to the TE again Example AT CMGF 1 OK AT CSMP 49 167 OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 0 0 1 OK AT CMGS 052468000 gt Hello CMGS 187 OK CDS 6 187 97252468000 145 05 08 03 08 56 34 08 05 08 03 08 56 34 08 70 AT CNMA OK H330 Module AT Command User Manual Page 125 of 304 Bs FIBOCOM 7 1 14 CMGL List Messages These commands display a list of all SMS with the status value lt stat gt from the H330 message storage lt mem1 gt selected using the CPMS command The command returns a series of responses one per message each item containing the message index status and data If the status of a message is RECEIVED UNREAD execution of the CMGL command changes the status of the message to RECEIVED READ Command Syntax Response Action Remarks Set CMGL lt stat gt If text mode CMGF 1 command execution is successful and SMS SUBMITs and or SMS DELIVERs CMGL lt index gt lt stat gt lt oa da gt lt scts gt lt tooa tod a gt lt length gt lt CR gt lt LF gt lt data gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt da oa gt l lt scts gt lt tooa to da gt lt length gt lt CR gt lt LF gt lt data gt l The parameters lt tooa toda gt lt length gt refer command shows the Text Mode Parameters CSDH and will be shown according to CSDH setting
186. et command disables or enables the use of result code CME ERROR lt err gt as an indication of an error relating to the functionality of the H330 When enabled H330 related errors cause a CME ERROR lt err gt final result code instead of the regular ERROR result code For all SMS AT commands that are derived from GSM 07 05 the CMEE Set command disables or enables the use of result code CMS ERROR lt err gt as an indication of an error relating to the functionality of the H330 When enabled H330 related errors cause a CMS ERROR lt err gt final result code instead of the regular ERROR final result H330 Module AT Command User Manual Page 40 of 304 Bs FIBOCOM Command Syntax Response Action Remarks nel eee on The Set command enables or disables siad or the use of result code CME ERROR CME ERROR lt err gt as an indication of an error relating to the functionality of the H330 lt err gt Read AT CMEE CMEE lt n gt The Read command returns the current OK setting format of the result code i Test pee MEE AE EE donc The Test command returns values Mppongd enes supported by the terminal as a OK compound value The following table shows the CMEE parameters lt Parameter gt Description lt n gt 0 Disable the CME ERROR lt err gt result code and use ERROR 1 Enable the CME ERROR lt err gt or CMS ERROR lt err gt result codes and use numeric lt err gt
187. ether the CACM command is functioning The following table shows the CACM parameters lt Parameter gt Description lt passwd gt SIM PIN2 password Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR incorrect password is displayed lt acm gt Accumulated call meter maximum value similar to CCM Refer to CAOC Advice of Charge The default value is 0 lt ccm gt String type three bytes of the current call meter value in hexadecimal format for example 00001E indicates a decimal value of 30 Value is given in home units bytes are similarly coded as the ACMmax value in the SIM Example AT CACM OK AT CACM CACM 000000 OK AT CACM 2222 OK 5 5 3 CAMM Accumulated Call Meter Maximum This command sets the Advice of Charge accumulated call meter maximum value in the SIM file EFACMmax ACMmax contains the maximum number of home units the subscriber is able to consume When the ACM Refer to CACM Accumulated Call Meter reaches ACMmax additional calls mobile originated and mobile terminated calls that incur charges are prohibited except for emergency calls Refer to GSM 02 24 Command Syntax Response Action Remarks Set CAMM OK The Set command sets the accumulated lt acm CME ERROR call meter maximum value SIM PIN2 is _max gt sets required The value that is set remains lt passw after a power cycle
188. f Oor1 3 8 Data 1 Stop default can be set only with lt parity gt 4 7 8 Data 1 Parity 2 Stop can be set with lt parity gt of Oor1 lt parity gt Determines how the parity bit is generated and checked if present 0 Odd 1 Even 4 No parity default Example AT ICF ICF 3 4 OK AT ICF ICF 1 3 7 0 1 4 OK AT ICF 3 4 OK 10 2 Other Parameter Commands 10 2 1 CBC Battery Charger Connection This command is used for user to query the battery voltage level Command Syntax Response Action Read CBC CBC lt bcs gt lt bcl gt OK H330 Module AT Command User Manual Page 181 of 304 Bs FIBOCOM The following table shows the CBC parameters lt Parameter gt Description lt bcs gt Battery status value 0 Battery powered 1 Externally powered not implemented in H330 Note The H330 input power source is connected via the battery pins only so itis always battery powered lt bcl gt VBAT voltage value A decimal number represents the digital value The input level is multiplied by 1000 Note H330 does not support the usage of battery power detect The power supply of H330 is connected via the battery pins However users can use this command to verify the level of H330 input power source Example AT CBC CBC 0 3802 OK 10 2 2 CFUN Shut Down Phone Functionality This command shuts down the phone functionality of smart phones and PDAs
189. ge RTT is 580 milliseconds MPINGSTAT 0 121 14 0 17 3 2 580 Ping host www sohu com 1 time with lt TTL gt 1 and lt size gt 1372 AT MPING 1 www sohu com 1 1372 1 OK CMP Time Exceeded message received TTL expired in transit MPING 192 168 252 65 11 0 Ping request execution is completed MPINGSTAT 0 121 14 0 17 1 0 14 16 MSDNS Set DNS IP Address This command set read DNS Domain Name Server IP address primary secondary for each socket If the user doesn t specify DNS servers by AT MSDNS H330 will use default DNS from NW The defined value s will be saved during disconnect PDP context can be used in next PDP context but will reset after power cycle Command Syntax Response Action Set AT MSDNS lt Socket_ID gt lt OK Primary_DNS_server_IP gt lt S oi econdary_DNS_server_IP gt l CME ERROR lt err gt Read AT MSDNS MSDNS 1 lt Primary_DNS_server_IP gt lt Secondary_DNS_server_ IP gt lt CR gt lt LF gt MSDNS 2 lt Primary_DNS_server_IP gt lt Secondary_DNS_server_ IP gt lt CR gt lt LF gt MSDNS 3 lt Primary_DNS_server_IP gt lt Secondary_DNS_server_ IP gt lt CR gt lt LF gt MSDNS 4 lt Primary_DNS_server_IP gt lt Secondary_DNS_server_ H330 Module AT Command User Manual Page 270 of 304 Bs FIBOCOM IP gt lt CR gt lt LF gt MSDNS 5 lt Primary_DNS_server_IP gt lt Secondary_DNS_server_ IP gt lt CR gt lt LF
190. gs for each defined context Test AT CGEQREQ CGEQREQ lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrate UL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s list of supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indication gt s lt CR gt lt LF gt CGEQREQ Test command returns values supported as a compound value If the MT supports several PDP types the parameter value ranges for each PDP type are returned ona separate line H330 Module AT Command User Manual Page 230 of 304 Bs FIBOCOM lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrate UL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s list of
191. gt IWF to MS window size 10 61 The default value is 61 lt mws gt MS to IWF window size 10 61 The default value is 61 lt T1 gt Acknowledgement timer T1 39 255 The default value is 48 lt N2 gt Retransmission attempts N2 in integer format refer to GSM 04 22 subclause5 4 3 The default value is 6 Example AT CRLP CRLP 10 61 10 61 39 255 1 255 OK AT CRLP CRLP 61 61 48 6 OK H330 Module AT Command User Manual Page 153 of 304 Bs FIBOCOM 9 1 3 CREG Network Registration Status This command is used to read current Network registration status and serving cell information Command Syntax Response Action Remarks ao ATFREGSI on The Set command controls the presentation shal or of an unsolicited result code and the result 4CME ERROR lt err of the Read operation Read AT CREG CREG The Read command returns the status of lt n gt lt stat gt lt lac gt lt ci the result code presentation whether the gt L lt AcT gt network has indicated the registration of OK H330 Location information elements lt lac gt and lt ci gt are returned only when lt n gt 2 and the H330 is registered in the network Test AT CREG CREG list of supported lt n gt s OK The following table shows the CREG parameters lt Parameter gt Description lt n gt 0 Disables the network registration unsolicited result code 1 Enables the network registration unso
192. gt String type 4 8 character old password specified for the facility from the H330 user interface lt newpwd gt String type 4 8 character new password specified by the user lt pwd length gt Maximum length of the facmility password Integer type Example AT CPWD CPWD SC 8 A0 8 O1 8 0X 8 Al 8 IR 8 AB 8 AG 8 AC 8 P2 8 OK AT CPWD CME ERROR operation not supported AT CLCK sc 1 current pin password OK H330 Module AT Command User Manual Page 148 of 304 Bs FIBOCOM AT CPWD sc incorrect old password new password CME ERROR incorrect password AT CLCK sc 2 CLCK 0 OK AT CPWD sc old password new password CME ERROR operation not allowed AT CLCK fd 1 current pin2 password AT CPWD p2 old password new password OK AT CLCK ai 2 CLCK 0 1 CLCK 0 2 CLCK 0 4 OK AT CLCK ai 1 correct password OK AT CLCK ai 2 CLCK 1 1 CLCK 1 2 CLCK 1 4 OK AT CPWD ai old password new password OK 8 1 6 CLCK Facility Lock This command locks unlocks or interrogates a H330 or a network facility lt fac gt any kind of call barring program A password is mandatory for performing locking and unlocking actions but not for querying The features of the H330 that are affected by this are fixed dialing list When querying the status of a single call barring program lt mode gt 2 the lt status gt for each
193. gt consist of several lt value gt parameters separated by commas Example of compound_value lt value1 gt lt value2 gt lt valueN gt Numeric Constants Numeric constants are expressed in decimal hexadecimal or binary form In the H330 the definition H330 Module AT Command User Manual Page 15 of 304 Bs FIBOCOM of each command specifies which form is used for values associated with that command String Constants String constants consist of a sequence of characters bounded at the beginning and end by the double quote character H330 Module AT Command User Manual Page 16 of 304 Bs FIBOCOM 3 Modem ID These commands allow the user to query the type of device that is attached the technology used in the device as well as basic operating information about the H330 3 1 CGMI GMI FMI Request Manufacturer ID These commands display manufacturer identification The H330 outputs a string containing manufacturer identification information Command Response Action AT CGMI CGMI lt manufacturer_ID gt AT CGMI OK AT GMI GMI lt manufacturer_ID gt AT GMI OK AT FMI FMI lt manufacturer_ID gt AT FMI OK Example AT CGMI CGMI Fibocom OK 3 2 CGMM GMM FMM Request Model ID These commands request the model identification The H330 outputs a string containing information about the specific model including a list of the supported technology used and the parti
194. h lt PDP_type gt supported lt delay gt s list of supported lt reliability gt s list of supported lt peak gt s list of supported lt mean gt s OK or CME ERROR lt err gt The following table shows the CGQMIN parameters lt Parameter gt Description lt cid gt Anumeric parameter that specifies a particular PDP context definition The value is from 1 to 10 For lt cid gt refer to defined values under CGDCONT command lt precedence gt Anumeric parameter that specifies the precedence class lt delay gt Anumeric parameter that specifies the delay class lt reliability gt Anumeric parameter that specifies the reliability class lt peak gt Anumeric parameter that specifies the peak throughput class lt mean gt Anumeric parameter that specifies the mean throughput class Example AT CGQMIN CGQMIN IP 0 3 0 4 0 5 0 9 0 18 OK AT CGQMIN CGOMIN 1 2 4 3 9 10 CGOMIN 2 2 4 3 9 10 OK 13 2 4 CGQREQ Quality of Service Profile Requested This command enables the terminal to specify a Quality of Service Profile that is used when the ME sends an Activate PDP Context Request message to the network H330 Module AT Command User Manual Page 214 of 304 Bs FIBOCOM ce gt s list of supported lt delay gt s list of supported lt reliability gt s list of supported lt peak gt s list of supported lt mean gt s OK
195. he result of the Read command For example if the SIM PIN is blocked the error code 11 or SIM PIN required is returned The user must then issue the Set command with the SIM PIN OK alphanumeric string indicating the status of the SIM card and whether a password is a required or not This is an independent SIM CME ERROR card lock status check only and does not lt err gt check the phone lock status Test AT CPIN OK H330 Module AT Command User Manual Page 143 of 304 Bs FIBOCOM The following table shows the CPIN parameters lt Parameter gt Description lt puk gt PUK code for unblocking a blocked phone lt pin gt Current PIN for unlocking a locked phone lt newpin gt New PIN after changing or after entering PUK 4 8 digits lt code gt READY MT is not pending for any password SIM PIN MT is waiting SIM PIN to be given SIM PUK MT is waiting SIM PUK to be given PH SIM PIN MT is waiting phone to SIM card password to be given PH FSIM PIN MT is waiting phone to very first SIM card password to be given PH FSIM PUK MT is waiting phone to very first SIM card unblocking password to be given SIM PIN2 MT is waiting SIM PIN2 to be given this lt code gt is recommended to be returned only when th e last executed command resulted in PIN2 authentication failure i e CME ERROR 17 if PIN2 is not entered right after the failure it is recommended that MT does not block its operation SIM PUK2
196. he DC voltage levels of the input pin The returned value is a multiplication of the input level by 1000 e g input level of 0 56V will return 560 Command Syntax Response Action Remarks Execute AT MMAD MMAD lt Converter_number gt lt Convert ed_Value gt OK Or CME ERROR lt err gt Read AT MMAD Same as AT MMAD H330 Module AT Command User Manual Page 184 of 304 Bs FIBOCOM The following table shows the MMAD parameters lt Parameter gt Description lt Converter Number gt 1 2 Select the A2D converter lt Converted Value gt A decimal value represents the returned digital value The input level multiplied by 1000 Example AT MMAD MMAD 1 500 500mV must less than 1000 MMAD 2 375 375mV must less than 1000 OK 10 2 5 MTSM Temperature Sensor Measurement This command measures the current temperature sensor value in Celsius degrees This temperature is taken from a Thermistor internally All the parameters restore to default values when H330 restart All the parameter default value is 0 Note In case that AT parameters are set and executed and a reset or a power cycle occurs the H330 continues with the execution of the AT command using the saved parameters until the user changes the settings Command Syntax Response Action Remarks Set MTSM lt Report For lt Report gt 0 Read the temperature gt lt Rate gt lt Low OK gt lt
197. hich has been specified by use of the CGDCONT command The parameter is local to the TE MT interface The list of permitted values is returned by the test form of the command lt d_comp gt Anumeric parameter that controls PDP data compression applicable for SNDCP only 0 off default if value is omitted 1 on manufacturer preferred compression 2 V42 bis Other values are reserved H330 Module AT Command User Manual Page 239 of 304 Bs FIBOCOM lt Parameter gt Description 3 RFC2507 lt h_comp gt A numeric parameter that controls PDP header compression 0 off default if value is omitted 1 on manufacturer preferred compression 2 RFC1144 applicable for SNDCP only 4 RFC3095 applicable for PDCP only Other values are reserved Example AT CGDSCONT CGDSCONT 2 1 0 0 OK AT CGDSCONT 1 1 ERROR AT CGDSCONT 2 1 1 3 OK AT CGDSCONT CGDSCONT 2 1 1 3 OK AT CGDSCONT CGDSCONT 1 20 IP 0 2 0 1 2 3 4 CGDSCONT 1 20 IPV6 0 2 0 1 2 3 4 OK 13 2 17 CGEREP Packet Domain Event Reporting This command is used to enable or disable sending of unsolicited result codes CGEV XXX from MT to TE in the case of events occurring in the Packet Domain Command Syntax Response Action Remarks Set CGEREP lt mod e gt lt bfr gt OK The Set command enables or disables sending of unsolicited result codes CGEV XXX from MT t
198. ice It returns the types of messages that are supported by the H330 Command Syntax Response Action Remarks Set CSMS CSMS lt mt gt lt mo gt lt bm gt The Set command sets the type of lt service OK service and returns the types of gt messages supported by the H330 or CMS ERROR lt err gt Read CSMS CSMS The Read command returns the Aenieoewisemos bm gt supported message types along with the current service setting OK oo ee POMS SSEIVICES The Test command returns a list of all i OK the services supported by the terminal The following table shows the CSMS parameters lt Parameter gt Description lt service gt Integer that defines the type of service 0 SMS AT command grammar is compatible with GSM Phase 2 1 SMS AT command grammar is compatible with GSM Phase 2 lt mt gt Mobile terminated messages 0 Not supported by the H330 1 Supported by the H330 lt mo gt Mobile originated messages 0 Not supported by the H330 1 Supported by the H330 lt bm gt Broadcast type messages 0 Not supported by the H330 1 Supported by the H330 H330 Module AT Command User Manual Page 105 of 304 Bs FIBOCOM Example AT CSMS CSMS 1 1 1 1 OK 7 1 2 CPMS Preferred Message Storage This command handles the selection of the preferred message storage area The message storage area is divided into three parts mem1 mem2 and mem3 Command
199. ifferent from FTPRETE command it is pure output no escape character So before output the data it will show the length of the output data it the buffer is empty then the data length will show 0 Note FTPGET command must be executed before use this command otherwise there is no data output The data in cache will be cleared if use FIPGET command again So before you use FTPGET again please make sure the data in the buffer are fetched to avoid losing data The data in thebuffer will be cleared when FTP is closed FTP connection will be closed automatically and buffer will be closed if the data cannot be fetched in 2 minutes Command Syntax Response Action Remarks FTPRECV FTPRECV lt LENGTH gt LENGTH DATA Shows the actual data length by serial port on after enter the output data stores in the buffer after the data output completed shows OK or ERROR Read AT FTPREC FTPRECV Vv lt available gt Read the data length stored in current buffer OK Test AT FTPREC FTPRECV Test the format of this command V 1 3000 LENGTH The following table shows the FTPRECV parameters H330 Module AT Command User Manual Page 291 of 304 Bs FIBOCOM lt Parameter gt Description lt available gt Length of the data stored in current buffer range 0 30720 lt LENGTH gt Length of the data need to be output range 1 3000 Example at ftpget 123 txt 0 do
200. illiseconds refer 3GPP TS 24 008 subclause10 5 6 5 lt Traffic handling Anumeric parameter 1 2 3 that specifies the relative importance for priority gt handling of all SDUs belonging to the UMTS bearer compared to the SDUs of other bearers refer 3GPP TS 24 008 subclause 10 5 6 5 lt Source Statistics Supported in R7 PS anumeric parameter that specifies characteristics of the Descriptor gt source of the submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 0 Characteristics of SDUs is unknown default value 1 Characteristics of SDUs corresponds to a speech source Other values are reserved lt Signalling Indication gt Supported in R7 PS a numeric parameter used to indicate confirmat content of submitted SDUs for a PDP context This parameter should be provided if the Traffic class is specified as interactive refer 3GPP TS 24 008 subclause 10 5 6 5 0 PDP context is not optimized for confirmat default value 1 PDP context is optimized for confirmat lt PDP_type gt See CGDCONT and CGDSCONT commands If a value is omitted for a particular class then the value is considered to be unspecified Example AT CGEQMIN CGEQMIN 1 0 0 0 0 0 0 0 0E0 0E0 0 0 0 0 0 H330 Module AT Command User Manual Page 228 of 304 Bs FIBOCOM CGEQMIN 6 0 0 0 0 0 0 0 0E0 0E0 0 0 0
201. inal during the PDP startup procedure or failing that a dynamic address is requested The Read form of the command continues to return the null string even if an address has been allocated during the PDP startup procedure The allocated address may be read using the CGPADDR command The default value is 0 lt d_comp gt Numeric parameter that controls PDP data compression 0 off default if value is omitted 1 on manufacturer preferred compression 2V 42 bis Other values are reserved The default value is 0 lt h_comp gt a numeric parameter that controls PDP header compression 0 off default if value is omitted 1 on manufacturer preferred compression 2 RFC1144 applicable for SNDCP only 3 RFC2507 4 RFC3095 applicable for PDCP only Other values are reserved lt pd1 gt lt pdN gt lt pd1 gt lt pdN gt zero to N string parameters whose meanings are specific to the lt PDP_type gt Example AT CGDCONT OK Only without any set command AT CGDCONT 1 IP CMNET OK AT CGDCONT 2 IP CMWAP OK AT CGDCONT CGDCONT 1 IP CMWAP 0 0 0 0 0 0 CGDCONT 2 IP CMNET 0 0 0 0 0 0 OK AT CGACT 1 H330 Module AT Command User Manual Page 212 of 304 Bs FIBOCOM OK AT CGDCONT CGDCONT 1 IP CMWAP 10 230 50 116 0 0 CGDCONT 2 IP CMNET 10 3 97 156 0 0 OK AT CGDCONT CGDCONT 1 10 IP 0 0 1 OK 13 2 3 CGQMIN Quality of Service
202. ing ping execution Only one ping request execution will be allowed at any given moment H330 Module AT Command User Manual Page 265 of 304 Bs FIBO COM Command Syntax Response Action Remarks Set MPING lt mo_ OK The set command shall send a lt count gt de gt L lt Destina or Internet Control Message Protocol ICMP Echo tion_IP hostna Request CME ERROR lt err gt Me beOual gt Messages to a target node defined by L lt size gt lt TTL n gs n lt Destination IP hostname gt parameter gt L lt TOS gt L lt Ti meOut gt If lt mode gt is equal 0 no parameters trailing lt mode gt parameter are allowed otherwise ERROR message will be reported to DTE If lt mode gt is equal 0 MS will abort sending Echo Request messages if ping request is in process otherwise ERROR message will be reported to DTE Unsolicited MPING The receipt of corresponding ICMP Echo Reply Response lt Destination_IP gt lt messages will be displayed within unsolicited type gt lt code gt responses along with round trip times L lt RTT gt Read MPING MPING The read command displays currently selected lt count gt lt size gt lt TTL parameters values for MPING set command If gt lt TOS gt lt TimeOut gt ping sending procedure is currently in process OK then user selected parameters for AT MPING command will be displayed otherwise default parameter values will be displayed Test MPING MPIN
203. ion Remarks Set ATE lt value gt OK The Set command sets whether or ei not to echo characters CME ERROR lt err gt Read ATE lt value gt The Test command for E is not OK defined by ITU and therefore is not supported by the H330 The H330 returns an error The following table shows the E parameters lt Parameter gt Description lt value gt 000 Does not echo characters 001 Echoes characters The default value is 001 Example ATE 001 OK 4 1 4 X Result Code Selection and Call Progress Monitoring Control This command defines the CONNECT result code format It determines whether or not the H330 transmits particular result codes to the user It also controls whether the H330 verifies the presence of dial tone when it first goes off hook to begin dialing and whether the engaged tone busy signal detection is enabled Command Syntax Response Action Remarks Set ATX lt value gt OK The Set command sets the result code and or call progress monitoring control CME ERROR lt err gt Read ATX lt value gt OK The following table shows the X parameters H330 Module AT Command User Manual Page 26 of 304 Bs FIBOCOM lt Parameter gt Description lt value gt 0 CONNECT result code given upon entering online data state Dial tone detection Disabled Busy detection Disabled 1 CONNECT lt text gt result code given upon entering online data state Dial
204. irectory ue ssesssssscsssecsseecsseecsseccsscesssecsnscessseessecesucecsucecssecssneccsseesssecsseesseessses 281 15 9 FTPCDUP Change Directory Up sessssscsssscssescsssecsseccsseecsseccsseecssessnseessseesscesusecsnecesneessneccsseecssecssseessseesses 281 15 10 FTPDEL Delete the File on esssssscsssccsseecsseecsseecssecsssecsssecsusecsusecsuecesscesneessseccsseesssessusessusessuscesseessneeesnees 282 15 11 FFTPREN Rename File on seessssscsssecsseccsscccsscccsneccsseccsseccsseccsnsecusecsssecsuseesnscessuscsnssesseecsueeesseccssecessseessneeeseesees 283 15 12 FTPLIST REQUESE LIStscns ccccnscststcsasesdeteasesaccaseetstossvasunceasoeustocsena oascedstopestoustoasteasteaseeaeeswue savbesseessteaseensmorsmnnasass 284 15 13 FTPSTAT Request Status scccccsccccscssstsascessconsdeatdensensstonsensstoasesastoaseeustoaveeasteasenastoavdbostoasvessoasdnsstosstnsstoessbostonss 285 H330 Module AT Command User Manual Page 10 of 304 Bs FIBOCOM 16 17 15 14 FTPSYST Request Operating System Type uu sessscssssseeesesessecssecssscsssessecssscsssesseesseessecsseessecsneesseesseeses 286 15 15 EF TIPNOOP No Oper ath mis cies cccsccesccds ccesccesccesicts sctscatscatvecds cats eats satvealbealiveatssatvealbectveatssebvcalbeelveatssativealveceacoenectins 287 15 16 FTPSTOR Store File on Remoter Server eessssccsssccsseccseccseccseesneeesseessecesseecsseccsseecssecesseecsseessseesseeesees 287 15 17 EF TIPRETR Retrieve a File seccsscsiscssiccss
205. it delete an existing entry from the phone book A particular entry in the phone book can be stored or the next available entry is used This command writes the entry in the currently active phone book selected with the CPBS command Refer to CPBS Select Phone Book Memory The entry is selected by lt index gt the phone number is entered into the lt number gt field and text associated with the number is entered into the lt text gt field If these fields are omitted the phone book entry is deleted If the lt index gt field is omitted but a number is entered in the lt number gt field the phone number is entered into the first available entry in the phone book If the writing fails in a H330 error CME ERROR lt err gt is returned Note The FD phone book supports single wild card characters and prefixes of a number in the telephone number field In cases of fixed dialing these entries in the FD phone book define a group of permitted numbers Call indications related to a fixed dialing entry containing wild cards or only a prefix of a number do not display any lt alpha gt identifier Command Syntax Response Action Remarks Set AT CPBW lt index gt lt OK number gt lt type gt lt text gt lt group gt lt adnumber gt L lt adtype gt lt secondte CME ERROR lt err gt xt gt lt email gt lt sip_uri gt l lt tel_uri gt L lt hidden gt 0 or H330 Module
206. k mode One is for AT command another is for send receive user data The default mode is for AT command Please use AT GTSET UARTMODE lt mode gt to switch work mode The following table shows the UARTMODE parameters lt Parameter gt Description lt mode gt 0 Uart2 use for AT command default 1 Uart2 use for send receive data 10 3 1 UART2 use for AT command When UART2 use for AT command most of AT commands can be supported Note UART2 can not support HW flow control No CTS RTS DTR DSR DCD RI pin The MUX feature can not support in UART2 10 3 2 UARTSEND Send data to UART2 When UART2 use for send receive data Please use AT GTSET UARTREV lt mode gt at the port which you H330 Module AT Command User Manual Page 191 of 304 Bs FIBOCOM want data receive The following table shows the UARTREV parameters lt Parameter gt Description lt mode gt 0 When receive data no report default 1 When receive data report all data by UARTREV 2 When receive data only report data lenght This command intends to send data to UART2 This command can be used in UART1 or USB ports to send data to UART2 The data format is in hex As the input command can only be character so here use two characters to indicate one hex number Eg 35 means 0x35 Module will change the format internally Command Syntax Response Action Remarks Set AT UARTSEN
207. ket AT MIPOPEN 3 3212 122 1 222 134 0 0 Listen to any port at specific IP OK MIPOPEN 3 1 122 1 222 134 1222 Remote side connected to the listen socket OK H330 Module AT Command User Manual Page 249 of 304 Bs FIBOCOM 14 3 MIPCLOSE Close a Socket This command causes the H330 to free the socket accumulating buffer and to close the socket Note All data stored in the accumulating buffer will be lost Command Syntax Response Action Set MIPCLOSE lt Sock OK et_ID gt lt Mode gt MIPCLOSE lt Socket_ID gt lt number_of_acknowledged_bytes gt lt close_t ype gt or ERROR Read MIPCLOSE MIPCLOSE lt socket_ID gt OK for all ACTIVE sockets or MIPCLOSE 0 OK if no active sockets Test MIPCLOSE MIPCLOSE 1 4 0 2 OK The following table shows the MIPCLOSE parameters lt Parameter gt Description lt Socket_ID gt Unique number that identifies a connection Valid socket numbers 1 2 3 and 4 lt Mode gt This value only used for TCP connection 0 Wait FIN ack from Server default 1 Do not wait FIN reponse from server 2 Wait 2MSL lt number_of_acknowledged_bytes gt Total number of bytes that were acknowledged lt close_type gt Connection close type 0 Connection was closed correctly 1 The remote side didn t reply so connection closed by close timeout 2 Other The remote side replied with
208. l format It is a Release 7 feature and describes access technology of the registered network Possible values of lt AcT gt are lt AcT gt 0 GSM 1 GSM Compact 2 UTRAN aes It is Release 7 feature string type one byte routing area code in hexadecimal rac format Intel Mobile H330 Module AT Command User Manual Page 156 of 304 Bs FIBOCOM Example at cgreg CGREG 0 2 OK AT CGREG 2 OK AT CGREG CGREG 2 1 A52F 0160358F 6 02 OK AT CGREG 1 OK AT CGREG CGREG 1 1 OK AT CGREG 0 OK 9 1 5 COPS Operator Selection This command enables accessories to access the network registration information and the selection and registration of the GSM UMTS network operator The H330 is registered in the Home network The Enhanced Operator Name String EONS feature enables the H330 to return the operator name displayed on the handset This feature allows the SIM card to store a mapping of MCC MNC code pairs to the displayed operator name As a result several operators can share a single network while having their handsets display their own name as the network operator Testing the enhanced ONS feature requires a SIM ONS SIM card Command Syntax Response Action Remarks Set AT COPS OK The Set command can force an attempt to select lt mo oe and register a specific GSM network operator dessin The lt mode gt selects whether this is done afk CME ERROR automatically by the H330 or whether the S
209. le This command must be use after MIPCALL is executed Command Syntax Response Action Remarks Set AT MIPCONF lt socket_ID gt L lt OK The Set command retr_num gt lt min_TO gt lt max ae updates TCP stack _TO gt lt max_close_delay gt configuration L lt is_nack_ind_req gt CME ERROR lt err gt parameters H330 Module AT Command User Manual Page 262 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read MIPCONF MIPCOMF The read command 1 lt retr_num gt lt min_TO gt lt m__ returns current ax_TO gt lt max_close_delay gt settings of TCP stack lt is_nack_ind_req gt lt CR gt lt LF gt parameters MIPCOMF 2 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt is_nack_ind_req gt lt CR gt lt LF gt MIPCOMF 3 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt is_nack_ind_req gt lt CR gt lt LF gt MIPCOMF 4 lt retr_num gt lt min_TO gt lt m ax_TO gt lt max_close_delay gt lt is_nack_ind_req gt lt CR gt lt LF gt OK Test MIPCONF MIPCOMF The Test command 1 4 1 12 1 10 10 600 1 returns the possible 75 0 2 parameters values OK Time values can be inserted with resolution of 100 milliseconds Parameter Description lt socket_ID gt Number of configured TCP socket 1 to 4 lt retr_num gt Number of retransmissions 1 to 12 default 12 lt min_TO g
210. le AT Command User Manual Page 32 of 304 Bs FIBOCOM 4 1 12 amp Y Default User Profile This command decides which user profile will be used after a power up cycle Command Syntax Response Action Set amp Y lt n gt OK or CME ERROR lt err gt The following table shows the amp Y parameters lt Parameter gt Description lt n gt User s profile number 0 Selects power up configuration to user s profile 0 1 Selects power up configuration to user s profile 1 The default value is 0 Example AT amp Y1 OK 4 1 13 CRSM Restricted SIM Access This command provides limited access to the Elementary Files on the SIM Access to the SIM database is restricted to the commands which are listed at lt command gt All parameters of AT CRSM are used as specified by 3GPP TS 51 011 2G and TS 31 101 3G As response to the command the H330 sends the actual SIM information parameters and response data Error result code CME ERROR may be returned if the command cannot be transferred to the SIM e g if the SIM is not inserted or defected or PIN1 PUK authentication required or required input parameters not present However failure in the execution of the command in the SIM is reported in lt sw1 gt and lt sw2 gt parameters Some of the AT CRSM commands require PIN PIN2 authentication Command Syntax Response Action Remarks Set AT CRSM lt _ CRSM Set command transmits the comma
211. licited result code CREG lt stat gt 2 Enables the network registration and location information in unsolicited reports and Read command CREG lt stat gt lt lac gt lt ci gt lt AcT gt The default value is 0 lt stat gt 0 Not registered and the ME is not currently searching for a new operator to register 1 Registered home network 2 Not registered but the ME is currently searching for a new operator to register 3 Registration denied 4 Unknown 5 Registered roaming lt lac gt Two byte location area code in hexadecimal format lt ci gt Four byte cell ID in hexadecimal format 0 GSM lt AcT gt 2 UTRAN H330 Module AT Command User Manual Page 154 of 304 Bs FIBOCOM 3 GSM w EGPRS 4 UTRAN w HSDPA 5 UTRAN w HSUPA 6 UTRAN w HSDPA and HSUPA Note lt Act gt is supporting only in R7 Protocol Stack AcT values 3 4 5 6 options are supported only in R8 PS Example AT CREG CREG 0 2 OK AT CREG CREG 0 1 OK AT CREG 2 OK AT CREG CREG 2 1 A52F 01603413 6 OK AT CREG 1 OK AT CREG CREG 1 1 OK AT CREG 0 OK 9 1 4 CGREG GPRS Network Registration This command gives the information of state of GPRS network registration Command Syntax Response Action Remarks Set AT CGREG lt n gt OK or CME ERROR lt err gt The Set command controls the presentation of an unsolicited result code CGREG and the result of the Read op
212. lready exists on the server this means the server support file transfer resume The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 already download data to cache Read FTPGET FTPGET lt filename gt lt viewmo Read the command mode state de gt lt eof gt OK Test FTPGET FTPGET file name 0 1 0 OxF PPEREFEJ Return command format OK The following table shows the FTPGET parameters lt Parameter gt Description lt filename gt A file name or a file path name string the max length is 255 octets lt viewmode gt Download mode 0 text mode 1 binary mode lt offset gt Download offset address range 0 OxFFFFFFFE lt eof gt 0 file downloading 1 All file data have been downloaded Example at ftpget 123 txt 0 download 123 txt OK H330 Module AT Command User Manual Page 290 of 304 Bs FIBOCOM FTPGET 2 data is downloaded FTPGET 1 download successfully at ftpget 123 txt 0 283800 download 123 txt start to download from offset address 283800 OK FTPGET 2 FTPGET 1 download successfully OK at ftpget 123 txt 0 293800 OK FTPGET 0 download failed the offset may higher then the max length 15 19 FTPRECV Read Data through the Port This command needs to be used with FTPGET command together it can output the data in the buffer from the port d
213. marks Set FTPOPEN OK FTPOPEN lt connection_status gt Command execution lt destination_ip url Or ERROR lt error code gt result connection status gt lt username gt return to the user as an lt password gt lt ac unsolicited response count gt lt source_con en 1 connection success trol_port gt lt destinati on_control_port gt 0 connection fail lt source_data_port gt Read FTPOPEN FTPOPEN lt connection_status gt OK Returns FTP connection status 1 connection success 0 no connection Test FTPOPEN FTPOPEN lt destination_ip url gt Returns command format lt username gt lt password gt L lt account gt range of supported port s range of supported port s range of supported port s OK H330 Module AT Command User Manual Page 275 of 304 Bs FIBOCOM The following table shows the FTPOPEN parameters lt Parameter gt Description destination_ip url IPor URL of remote FTP site The range of IP address is 0 255 IP address format XXX XXX XXX XXX URL format www XXX com string format the max length is 255 octets username Registered Username for FTP Server string the max length is 255 octets password Registered Password for FTP Server string the max length is 255 octets account User Account Some FTP server not only need username password but also need account input this information if it is required String the m
214. marks Set AT GTRAT lt AcT gt OK or SPretene diet CME ERROR lt error gt Read AT GTRAT GTRAT lt Act gt lt PreferredAct gt OK Test AT GTRAT GTRAT 0 2 0 2 Note i e list of supported OK lt Act gt s and list supported lt PreferredAct gt s H330 Module AT Command User Manual Defined values lt AcT gt indicates the radio access technology and may be 0 GSM single mode 1 GSM UMTS Dual mode 2 UTRAN UMTS lt PreferredAct gt This parameter is used for network registration in case of lt AcT gt 1 0 RAT GSM 2 RAT UMT Page 173 of 304 Bs FIBOCOM 10 Hardware Information 10 1 Uart Parameter Commands 10 1 1 CBAUD Baud Rate Regulation This command sets the uniquely UART baud rate The baud rate of H330 will be change set to the request value lt rate gt which is get from the command Specifying a value of 0 1 or 9 allows operation only at rates automatically detectable by H330 The specified rate takes effect following the issuing of any result code s associated with the current command line Note ATZ and AT amp F command sets H330 to default baud rate 0 In auto baud must sent an AT command to H330 firstly After sent any AT command the module will lock on single baud rate this AT command will be lost and can not get reponse from H330 Read command can feedback the currently baud rate The module can not be changed to auto baud without send AT CBAUD 0 1 or 9 command or after
215. meter gt Description lt band_1 gt or 0 Automatic band selection lt band_2 gt or UMTS2100 Selection of UMTS_BAND_I 2100MHz band lt band_3 gt or UMTS1900 Selection of UMTS_BAND_II 1900MHz band lt band_4 gt UMTS850 Selection of UMTS_BAND_V 850MHz band UMTS900 Selection of UMTS_BAND_ VIII 900MHz band Note For registering 3G network only Example AT CUBAND CUBAND UMTS2100 UMTS1900 UMTS850 UMTS900 OK AT CUBAND H330 Module AT Command User Manual Page 165 of 304 Bs FIBOCOM CUBAND 0 UMTS2100 UMTS1900 UMTS850 UMTS900 OK AT CUBAND UMTS2100 OK AT CUBAND CUBAND UMTS2100 OK 9 1 9 XREG Current Network Registration Status This command reports where the device is attached to URC syntax XREG lt Status gt lt Band gt Command Syntax Response Action Remarks Set AT XREG lt n gt OK or Set command enables disables network CME ERROR lt error gt registration status unsolicited result code XREG URC same as read syntax Read AT XREG XREG Read command gives the status of OK Test AT XREG XREG list of Test command returns list of supported supported lt n gt s lt n gt OK The following table shows the XREG parameters NO UW AUN registered GPRS attached registered EDGE attached registered WCDMA attached registered GSM 8 registered HSPA attached
216. meter that specifies the delay class lt reliability gt Anumeric parameter that specifies the reliability class lt peak gt Anumeric parameter that specifies the peak throughput class lt mean gt Anumeric parameter that specifies the mean throughput class H330 Module AT Command User Manual Page 215 of 304 Bs FIBOCOM Example AT CGQREQ CGQREQ IP 0 3 0 4 0 5 0 9 1 18 31 OK AT CGQREQ CGQREQ 1 2 4 3 9 10 CGQREQ 2 2 4 3 9 10 OK AT CGQREQ 1 0 0 0 10 OK AT CGQREQ CGQREQ 1 0 4 0 0 10 CGQREQ 2 2 4 3 9 10 OK 13 2 5 CGATT GPRS Attach or Detach This command attaches detaches the ME to from the GPRS service When the command has completed the ME remains in V 25ter command state If the ME is already in the requested state the command is ignored and the OK response is returned If the requested state cannot be achieved an ERROR or CME ERROR response is returned Extended error responses are enabled by the CMEE command Any active PDP contexts will be automatically deactivated when the attachment state changes to detached Command Syntax Response Action Remarks Set AT CGATT OK The Set command attaches detaches the ME to from lt state gt or the GPRS service CME ERROR lt err gt Read AT CGATT CGATT lt state gt The Read command returns the OK current GPRS service state Test AT CGATT CGATT list of The Test command requests supported lt state gt
217. meters lt Parameter gt Description lt imei gt The IMEI International Mobile Station Equipment Identity number is composed of 15 digits as specified by 3GPP TS 23 003 IMEI numbers are composed of the following elements all in decimal digits Type Approval Code TAC 8 digits Serial Number SNR 6 digits Spare digit 1 digit The TAC and SNR are protected against unauthorized changes Example AT CGSN CGSN 004400013805666 OK 3 5 CSCS Select Terminal Character Set This command selects the H330 character set The H330 supports the following character sets IRA GSM UCS2 HEX The default value is IRA Command Syntax Response Action Set CSCS lt chset gt OK or CMS ERROR lt err gt Read CSCS CSCS lt selected character set gt OK Test CSCS CSCS lt supported character sets gt OK The following table shows the CSCS parameter optional values lt chset gt Character Set IRA International Reference Alphabet ITU TT 50 GSM GSM default alphabet GSM 03 38 subclause 6 2 1 UCS2 2 byte Universal Character Set Unicode ISO IEC 10646 32 HEX Charater strings consist only of hexadecimal numbers from 00 to FF H330 Module AT Command User Manual Page 19 of 304 Bs FIBOCOM Example AT CSCS CSCS UCS2 IRA HEX GSM OK AT CSCS CSCS IRA OK AT CPBS SM OK AT
218. mory Test CPBS CPBS list of Test command returns the supported lt storage gt supported storages as a s compound value OK H330 Module AT Command User Manual Page 93 of 304 Bs FIBOCOM The following table shows the CPBS parameters lt Parameter gt Description lt storage gt List of supported phone books and their storage IDs FD SIM Fixed dialing phone book ON Own numbers MSISDNs list reading this storage is also available through CNUM SM SIM phone book LD SIM last dialing phonebook BL Blacklist phonebook delete only EC SIM emergency call codes phonebook read only AP Selected application phonebook BN SIM barred dialling number phonebook only valid with PIN2 SN SIM service dialling number phonebook The default phone book is SM lt used gt Integer type value indicating the number of used locations in the selected memory lt total gt Integer type value indicating the total number of entries in the selected phone book memory lt pin2 gt String type PIN2 password 4 8 digits Example AT CPBS SM OK AT CPBR CPBS SM FD SN LD ON EC BL OK AT CPBR 1 OK AT CPBR 1 3 There is nothing written in entry 1 2 3 OK AT CPBS FD lt correct pin2 gt OK CPBW pin2 unlocked AT CPBW 1 034546565 129 xyz Write into FD storage OK H330 Module AT Command User Manual Page 94 of 304 Bs FIBOCOM AT CPBS FD lt wrong pin2 gt
219. mplate escssssscssssscsssscccsssecssnsecssnsecessscsessuecessuecessnseessnsecessseesssueecssneeesnseesste 241 13 2 19 MGAUTH Set type of AUtTHeNtication ecssssccsssseccssescesseesesssecccsuescssnecesnsecessseeecsneeessneeessneessee 245 14 TCP IP isisisi a decane svbccobadeteugessbnsuboor an cbGhobsedennsttenegessevenabensceabaddber 246 14 1 MIPCALL Create a Wireless Link essssssssssccsssccssscenesscnsccesscscsscsssecessscsssseenesssneeeenececnecssnscssssessseessesesses 246 H330 Module AT Command User Manual Page 9 of 304 Bs FIBOCOM 14 2 MIPOPEN Open a Socket UDP or TCP sssssssccsssccsssecsseccsscessscessseessseessscesneeesucccsseesssecesseesssecssseessseeseee 247 14 3 FEMIPCLOSE Close a SOCK acess cccscccsccsbceeacuncoussceucscnsebansencobeccuvcatascnnassocsyecsancabscsennspacsbocedecsbucensansaseecovectecctavs 250 14 4 MIPSETS Set Size and Timeout for Automatic PUSH ssescsssecccssesccsseeccsnseccssseccssseecesueecssneessnseees 251 14 5 MIPDSETS Set Size and Timeout for Output Data eessseccsssescrssescssneecssnseecssseeccsusecssneccssneecesseeees 253 14 6 MIPSEND Send Data ccsicascciscusvssuscetsccaucsvaccsscouscconccanscasscutecsbucnescatusensnssanssncous EREE EN 254 14 6 1 Send Data at normal MOde sesssssssssscssssesssscesssesnesecssssenecesneeecnscessecesseesssecesssessseceneeeeneeeneeeeneeess 254 14 6 2 Send Data at HEX Mode sssscssccssccsscsssccovesssssnsnseacavecstvcatasssnnsearstec
220. mum SDU size gt Anumeric parameter 1 2 3 that indicates the maximum allowed SDU size in octets refer 3GPP TS 24 008 subclause 10 5 6 5 lt SDU error ratio gt A string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous SDU error ratio is defined only for conforming traffic The value is specified as mEe As an example a target SDU error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQMIN2 5E3 refer 3GPP TS 24 008 subclause 10 5 6 5 H330 Module AT Command User Manual Page 227 of 304 Bs FIBOCOM lt Parameter gt Description lt Residual bit error ratio gt A string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs If no error detection is requested Residual bit error ratio indicates the bit error ratio in the delivered SDUs The value is specified as mEe As an example a target residual bit error ratio of 5 10 3 would be specified as 5E3 e g AT CGEQMIN 5E3 refer 3GPPTS 24 008 subclause 10 5 6 5 lt Delivery of erroneous Anumeric parameter that indicates whether SDUs detected as erroneous SDUs gt shall be delivered or not 0 no 1 yes 2 nodetect Other values are reserved lt Transfer delay gt Anumeric parameter 0 1 2 that indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in m
221. n GSM standard character sets and extended GSM characters require additional space in storage In some cases when using such characters the text cannot be stored In this case the H330 returns a text string too long error lt hidden gt indicates if the entry is hidden or not only available if a UICC with an active USIM application is present 0 phonebook entry not hidden 1 phonebook entry hidden lt group gt string type field of maximum length lt glength gt character set as specified by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt H330 Module AT Command User Manual Page 100 of 304 Bs FIBOCOM lt Parameter gt Description lt adtype gt type of address octet in integer format refer TS 24 008 subclause 10 5 4 7 lt secondtext string type field of maximum length lt slength gt character set as specified by gt command Select TE Character Set CSCS lt email gt string type field of maximum length lt elength gt character set as specified by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt lt alength gt integer type value indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of fiel
222. n identifier value 1087 User not member of CUG 1088 Incompatible destination 1091 Invalid transit network selection 1095 Semantically incorrect message 1096 Invalid mandatory information 1097 Message type non existent or not implemented 1098 Message type not compatible with protocol state 1099 Information element non existent or not implemented 1100 Conditional IE error 1101 Message not compatible with protocol state 1102 Recovery on timer expiry 1111 Protocol error unspecified 1127 Interworking unspecified 1279 Number not allowed 1283 CCBS possible 17 2 CMS Error Parameter Description lt Err gt 1 Unassigned unallocated number 8 Operator determined barring 10 Call barred 17 Network failure 21 Short message transfer rejected 22 Memory capacity exceeded 27 Destination out of service 28 Unidentified subscriber 29 Facility rejected H330 Module AT Command User Manual Page 299 of 304 Bs FIBOCOM 30 Unknown Subscriber 38 Network out of order 41 Temporary failure 42 Congestion 47 Resources unvailable unspecified 50 Requested facility not subscribed 69 Requested facility not implemented 81 Invalid short message reference value 95 Invalid message unspecified 96 Invalid mandatory information 97 Message type non existent or not implemented 98 Message not c
223. nd displays the list of OK supported CR modes The following table shows the CR parameters lt Parameter gt Description lt mode gt 0 Extended format disabled default 1 Extended format enabled lt serv gt Type of outgoing data calls ASYNC Asynchronous transparent SYNC Synchronous transparent REL ASYNC Asynchronous non transparent REL SYNC Synchronous non transparent Example H330 Module AT Command User Manual Page 83 of 304 Bs FIBOCOM AT CR 1 Enable reporting OK ATD1234567890 CR RELASYNC 5 6 Supplementary Services This set of commands enables control over supplementary service notifications including Structured and Unstructured Supplementary Service Data USSD data 5 6 1 CSSN Supplementary Service Notifications This command handles the enabling and disabling of supplementary service related network initiated notifications Command Syntax Response Action Remarks Set CSSN OK The Set command enables disables the lt n gt L lt display of notification result codes to the or m gt TE CME ERROR When lt n gt 1 and a supplementary service lt err gt notification is received after a mobile originated call setup the CSSI notification is sent to the TE before any other mobile originated call setup result codes When several different notifications are received from the network each of them receives its own CSSI result code When
224. nd gt l SIM lt command gt and its lt sw1 gt lt sw2 gt lt response lt file_id gt lt P required parameters to the ME gt 1 gt lt P2 gt lt P3 gt L lt data gt lt OK pathid gt or ME sends the actual SIM infor mation parameters and response data CME ERROR lt err gt H330 Module AT Command User Manual Page 33 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CRSM CRSM The test command returns the 3 list of possible ranges of CRSM supported lt command gt s Parameraig possible lt file_id gt s range value possible lt P1 gt range value possible lt P2 gt range value possible lt P3 gt range value OK or CME ERROR lt err gt The following table shows the CRSM parameters lt Parameter gt Description lt command gt Integer type Command passed on by the ME to the SIM 176 Read BINARY 178 Read RECORD 192 Get RESPONSE 214 Update BINARY 220 Update RECORD 242 STATUS lt file_id gt Integer type This is the identifier of a elementary data file on SIM Mandatory for every lt command gt except of STATUS lt P1 gt lt P2 gt lt P3 gt Integer type Parameters passed on by the ME to the SIM These parameters are man datory for every command except GET RESPONSE and STATUS READ BINARY lt P1 gt Offset high 0 255 lt P2 gt Offset low 0 255 lt P3 gt Length 0
225. ndling network requests for PDP context activation The setting does not affect the issuing of the unsolicited result code RING or CRING peu Syntax Response Action Remarks Set AT CGAUTO OK The set command disables or enables an lt n gt Or automatic positive or negative response auto answer to the receipt of a NW CME ERROR lt error gt initiated Request PDP Context Activation message from the network Read AT CGAUTO CGAUTO lt n gt The read command returns the current OK setting for the auto answer whether it s enabled or disabled Test AT CGAUTO CGAUTO list of supported The test command returns the values of lt n gt s lt n gt supported by MT as a compound OK value The following table shows the CGAUTO parameters lt Parameter gt Description lt n gt Is anumeric parameter which indicates the setting for the auto answer to be used 0 Turn off automatic response for Packet Domain only Packet Domains network requests are manually accepted or rejected by the CGANS command 1 Turn on automatic response for Packet Domain only Packet Domain network requests are automatically accepted according to the description above 2 Modem compatibility mode Packet Domain only H330 Module AT Command User Manual Page 223 of 304 Bs FIBOCOM Automatic acceptance of Packet Domain network requests is controlled by the SO command Manual control uses the A and H commands respectively to ac
226. nds Within the timeout the H330 will not send another unsolicited response to the TE before the previous one is acknowledgement If the H330 does not receive acknowledgment within the required time CNMI parameters will NOT be reset automatically and the unsolicited response will send to the TE again Command Syntax Response Action net CNMI lt mode gt L lt mt OK gt L lt bm gt lt ds gt lt bfr gt or MM CMS ERROR lt err gt CNMI lt mode gt lt mt gt lt bm gt lt ds gt lt bfr gt Read CNMI OK Test CNMI CNMI list of supported lt mode gt s list of supported lt mt gt s list of supported lt bm gt s list of supported lt ds gt s list of supported lt bfr gt s OK The following table shows the CNMI parameters lt Parameter gt Description 0 Buffer unsolicited result codes in the TA if the TA buffer is full the oldest indication may be discarded and replaced with the new received indications ring buffer 1 Discard indication and reject new received message unsolicited result lt mode gt codes when TA TE link is reserved otherwise forward them directly to the terminal 2 Buffer unsolicited result codes in the TA when the serial link is busy e g data transfer otherwise forward them directly to the terminal 0 No SMS DELIVER indications are routed to the terminal default 1 If SMS DELIVER is stored in the H330 the memory location indicati
227. ne If the call is terminated and another call is answered OK call answered and is now connected NO CARRIER Command Syntax Response Action Remarks Test CHLD CHLD list of supported The Test command returns lt n gt values lt n gt s supported by the H330 to the terminal OK H330 Module AT Command User Manual Page 59 of 304 Bs FIBOCOM The following table shows the CHLD parameters Parameter n Description 0 Release all held calls or set User Determined User Busy for a waiting incoming call if both exists then only the waiting call will be rejected 1 Releases all active calls and accepts the held or waiting call Note In the scenario An active call a waiting call and held call when the active call is terminated we will make the Waiting call as active 1x Release a specific call x specific call number as indicated by CCLC 2 Place all active calls if exist on hold and accepts the other call held or waiting incoming If only one call exists which is active place it on hold and if only held call exists make it active call 2x Place all active calls on hold except call x with which communication is supported 3 Adds a held call to the conversation 4 Connects the two calls and disconnects the subscriber from both calls Explicit Call Transfer 6 E Puts an active call on hold or an held call to active while another call is waiting 7 Disconnect users in mul
228. nections The following table shows the S2 parameters lt Parameter gt Description lt escape_character gt CSD escape character Range is 1 to 255 The default value is 43 4 1 7 S12 This command handles the selection of the guard time which is stored in S Register 12 and specifies the behavior of escape characters during CSD connection Note Fora guard time specified by S Register 12 no character should be entered before or after The duration between escape codes must be smaller than the guard time Command Syntax Response Action Remarks Set 12 lt guard_ OK The Set command sets the CSD escape time gt CME ERROR lt err gt character guard time value if all parameters are valid Read 12 lt guard_time gt The Read command displays the OK current CSD escape character guard time The following table shows the S12 parameters lt Parameter gt Description lt guard_time gt The defa ult value is 20 CSD escape character guard time units of 50 msec Range is 0 to 255 H330 Module AT Command User Manual Page 29 of 304 Bs FIBOCOM 4 1 8 amp V View Configuration This command reports the current S registers and the stored user profile Command Syntax Response Action Remarks Execute amp V ACTIVE PROFILE The Execute command displays the current active configuration and stored user profiles profile data STORED PROF
229. new SMS DELIVER SMS if the CNMI parameter lt mt gt is set to 2 Refer to CNMI New Message Indications to Terminal This unsolicited message displays the received SMS DELIVER message In text mode CMGF 1 CMT lt oa gt lt scts gt lt tooa gt lt fo gt lt pid gt lt dcs gt lt sca gt lt tosca gt lt length gt lt CR gt lt LF gt lt data gt H330 Module AT Command User Manual Page 120 of 304 Bs FIBOCOM about parameters in italics refer command Show Text Mode Parameters CSDH In PDU mode CMGF 0 CMT lt alpha gt lt length gt lt CR gt lt LF gt lt pdu gt The following table shows the CMT parameters lt Parameter gt Description lt oa gt Message origination address lt scts gt Service center time stamp lt tooa gt Type of origination address lt fo gt First octet of the SMS lt pid gt Protocol Identifier lt dcs gt Data Coding Scheme lt sca gt Service Center Address lt tosca gt Type of Service Center Address lt data gt Message contents lt alpha gt Alpha ID of message lt length gt In PDU mode Size of message in octets excluding SMSC data In TEXT mode number of characters included in the lt data gt lt pdu gt Message header and contents in PDU mode format See description in CMGR Read Message After sending a CMT unsolicited response to the TE the H330 will expect a CNMA new message a
230. ng Line Identification Restriction ssssssssssscsssescsssescsssesessnsecessecsssseeeesueeessneeessneessee 63 5 3 14 CBST Select Bearer Service Type uu sesssssscsssscsseecssssesseecsssecsseccsseccsseccsseessseessseessseesuecesueeesseeesueeesneessee 66 H330 Module AT Command User Manual Page 5 of 304 Bs FIBOCOM 5 3 15 O Return to Online Data State wc sscsssssssssssssssssscsssssssssessssssssssssssssssssssssscssssssssssssessssssesess 69 5 3 16 CHUP Hang Up Calle ass sasicoesccascetscistasibesuscouscautndasabaasuncebuecussatagennsseacstvcnassabsdecousbbestecobacsbeseencensavencteectens 69 5 3 17 MDC Selection of Desired Message to Be Displayed Upon Connection of a Voice Call 70 5 3 18 MHUR H330 HUNG UP Call sicscsssccsscsanssssvnsscosscanvsssevosanseacobecstveetasesnaseasasecsnscabussancabaosbecabesabucseasennaveecayectoec 71 5 4 Call Status MESSAGES iiciin aeisi EEr ES EEE ENER E RTE 72 5 4 1 CPAS Phone Activity St tUS issssiiiisiicsirssisriisiiiiii iei N 72 5 4 2 CLCC List C rrent CallStreet raske rE EE k E 73 5 4 3 MCST Call Status M SSAaGeS snsscsssssrsesernesernessrnessonscsonsesonsesoseessssersesessesornessenersrnessenossenessonessonsesosees 75 5 5 Call Advice of Charge Commands evsssiisesssinscssccncccannsscccevecasavessctussanccsccctavsscsavescoansevecavecanasavecenssecossecchasspivaveleat 77 5 5 1 AGCAOG Advice Of CHANG saiscasscc sasavccussctinsisccesccnssstucctuaseavatevelavstonsnsscnnwsltecaseconsvececev
231. nge of 0 255 Valid values are defined according to GSM03 40 v7 4 0 section 9 1 2 5 as follow Bit 7 is 1 Bits 6 5 4 Present Type of number as follow Bits 6 5 4 0 0 0 Unknown 001 International number 0 1 0 National number 01 1 Network specific number 100 Subscriber number 101 Alphanumeric coded according to GSM TS 03 38 7 bit default alphabet 11 0 Abbreviated number 11 1 Reserved for extension Numbering plan identification applies for Type of number 000 001 010 Bits 3210 0000Unknown 0001 ISDN telephone numbering plan E 164 E 163 001 1 Data numbering plan X 121 0 100Telex numbering plan 1000 National numbering plan 1001 Private numbering plan 10 1 0 ERMES numbering plan ETSI DE PS 3 01 3 1111 Reserved for extension All other values are reserved H330 Module AT Command User Manual Page 109 of 304 Bs FIBOCOM CSCA lt SCA gt parameters Following table describes CSCA lt SCA gt valid parameters including the conversion when using stored lt SCA gt in SMS PDU mode editing SMS via CMGW or CMGS without SCA This is according to 24 008V031000P Table 10 5 118 GSM 24 008V031000P Called party BCD number lt SCA gt Character in SMS Text mode Mapped character for SMS PDU mode Digits 0 9 Digits 0 9 0x91 ET N my g N ra g D ra F Example AT CSCA CSCA 97212356 145 Read SCA address and TOSCA stored in SIM EF smsp OK AT CSCA 972123
232. ngth The time limit of consecutive DTR toggles is a minimum of 90 seconds The H330 specific is not designed to support online command and data states both at the same time therefore any wrong or extreme usage can cause unexpected behaviors The basic GPRS concept is be always connected and there is no charge for being connected only per real data transferred 13 2 GPRS Commands This section defines commands that a terminal may use to control a GPRS ME GPRS MTs vary widely in functionality A class AME might support multiple PDP types as well as circuit switched data and use multiple external networks QoS profiles At the other extreme a class C ME might support only a single PDP type using a single external network and rely on the HLR to contain the PDP context definition A comprehensive set of GPRS specific commands is defined below to provide the flexibility needed by the more complex ME The commands are designed to be expandable to accommodate new PDP types and interface protocols merely by defining new values for many of the parameters Multiple contexts may be activated if the interface link layer protocol is able to support them The commands use the extended information and error message capabilities described in this specification For MTs of intermediate complexity most commands have simplified forms where certain parameters may be omitted For the simplest MTs and for backwards compatibility with existing communications softwar
233. ning mobile class B CC class C in GPRS mode CG class C in circuit switched mode Example AT CGCLASS CGCLASS A B CCCG OK Note If a SIM card without GPRS allowance is used AT CGCLASS CGCLASS CC Note that CC is a not supported value 13 2 2 CGDCONT Define PDP Context This command specifies the PDP Packet Data Protocol context This command allows specifying specific PDP context parameter values for a PDP context identified by the local context identification parameter lt cid gt If the command is used only with the one parameter lt cid gt it means that the corresponding PDP context becomes undefined H330 Module AT Command User Manual Page 210 of 304 Bs FIBOCOM supported lt cid gt s lt PDP_type gt list of supported lt d_comp gt s list of supported lt h_comp gt s OK Command Syntax Response Action Remarks Set AT CGDCONT OK The Set command specifies the lt cid gt or context identification parameter lt PDP_type gt values for a PDP context A lt APN gt CME ERROR lt err gt special form of the Set lt PDP_addr gt command CGDCONT lt cid gt saLcomp gt causes the values for context lt hcomp gt number lt cid gt to become apa iboek undefined pdN J Read AT CGDCONT CGDCONT lt cid gt The read command returns the lt PDP_type gt current settings for each defined lt APN gt lt PDP_addr gt context lt
234. nnsesbssecossbasvescebecrsvcatavesunseasabecsuascbusveneseds 255 14 7 GTSET Set receive data mode uu sssssccsssccsssscsscsssscssssesssscsnssesnsssenssesnecseneeeenecesnecsensessnecssesessseessesessesesses 257 14 8 MIPPUSH Push Data into Protocol Stack ee csssssssccsseecsseessscessscessscessecessecesseecsneccsseccsseecsseessseessseesees 259 14 9 MIPFLUSH Flush Data from Buffers sssssccsssscccssscccssseccsneeccsssecesssscessnscessuseessnseeesnsecessneecssnecessneessnseees 260 14 10 MIPRUDP Receive Data from UDP Protocol Stack ssessssssscsssseccssnseesssececsnseessnecessnseecesncesneesesseeees 261 14 11 MIPRTCP Receive Data from TCP Protocol Stack sssssscsssssscsssescessescssnssessnssecssseecsensescessccesneeessesees 261 14 12 AMIPSTAT Status Repol t zs ceesccescceccessscs cose ccesstucceccseuectcaten cath ees coed abvesencaue NENN 262 14 13 MIPCONF Configure Internal TCP IP Stack ssssssscssssscssssscccssscessssscesnecssssecessseecssuecssneessnseeessneeessues 262 14 14 MPING Start Ping Execution ICMP Protocol sessssscsssscsssecssescsseecssescsseccsseecsseccsseccssecsneecsseeesueeessecs 265 14 15 MPINGSTAT Status Update for MPING Execution ssseccsssssscssssccssseccssseccesseeessusscssnsecsssseesssneesssnsess 268 14 16 MSDNS Set DNS IP Address esssssssssescsssecsseccsseccsseecsseccsseccssecssscesssccsuseesusscsuecesseecsnecessecsssecssseessseesuesssees 270 14 17 MIPODM Open a Sock
235. nses and result l codes CME ERROR lt err gt The following table shows the V parameters lt Parameter gt Description lt value gt 0 Transmits limited headers and trailers and numeric text 1 Transmits full headers and trailers and verbose response text The default value is 1 H330 Module AT Command User Manual Page 24 of 304 Bs FIBOCOM Example ATVO 0 ATV1 OK 4 1 2 Q Result Code Suppression This command determines whether to output the result codes Information text transmitted in response to commands is not affected by the setting of this parameter Command Syntax Response Action Remarks Set ATQ lt value gt OK The set commands sets whetheror Sr not to output result codes CME ERROR lt err gt Read ATQ Q lt value gt OK The following table shows the Qn parameters lt Parameter gt Description lt value gt 0 Transmit result codes 1 Suppress result codes The default value is 0 Example ATQO OK ATQ Q 0 OK ATQ4 ERROR ATQ1 No response because result codes are suppressed ATQ4 H330 Module AT Command User Manual No response because result codes are suppressed Page 25 of 304 Bs FIBOCOM 4 1 3 E Command Echo This command defines whether input characters are echoed to output If so these characters are echoed at the same rate parity and format at which they were received Command Syntax Response Act
236. nsists of ctory_n ame gt Or ERROR the directory name as well as the directory lt error_code gt path optional The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPCWD ERROR Not supported Test FTPCWD FTPCWD lt directory Returns command format name gt OK The following table shows the FTPCWD parameter lt Parameter gt Description Directory name Opend file directory or file name String max length is 255 octets Example AT FTPcwd Acrobat OK FTPCWD 1 15 6 FTPMKD Make Directory This command is used for creating a specified directory in a path name for absolute path name or subdirectory of current working directory for relative path name Command Syntax Response Action Remarks Set FTPMKD lt direc OK FTPMKD lt result gt lt directory_name gt parameter is the tory_name gt Or ERROR directory name need to be created The lt error_code gt command execution result return to the user as an unsolicited response 0 operation fails 1 operation success H330 Module AT Command User Manual Page 279 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read FTPMKD ERROR Not supported Test FTPMKD FTPMKD lt directory Returns command format name gt OK The following table shows the FTPMKD paramet
237. nsor MEaSUreMEeN ecsescsescsescseseseesssesseenesensscnssesseesssenseenssenseenseeneees 185 10 2 6 WRIM RI signal Width Setting 0 esesssssecsseecsseecsseecsseccsseccsseecsseceesecssecssseessseessseesuecsuneeaseesneeesee 188 10 2 7 MSTART Start message Notification csessccssssccssscssssecccsseecssnecesssecessueeessnecesnsecscsseecesneeessneeessee 188 10 2 8 MSMPD Enable Disable SIM card hot Plug sesssssecssescssescssescsseccsssecsseccsseecssecsnscesseeesneeeseseess 189 10 2 9 GPIO Set ANd Read GPIO ww eessssescsseccsseccsseecsseccssecssseesssccsssecsusccsuscesseccsneecsnecesseessseesuseesusessueeessseess 190 10 3 UART2 CONFIQUIATION seccsssssccssescesssecesssecersnsccssnscessnsccessscessusccesusccesuscessssecessuscessuseessnscessssecessuecessnecessneceessees 191 10 3 1 UART2 Use for AT COMMANA essssssssccssescesnesccsnsccessseccesueccssnsccesnsccesssecessnscessucessusecesaseecssneeessneeesneeees 191 10 3 2 UARTSEND Send data to UART2 ssessssscsseecsssessscessccsssecsseccsusecsseccsseessseecssecssseesnseesneesneesnseess 191 MDS PACA e ERR E R ASR R RERNI 193 11 1 SSC OPIS PATEA ENNA TENA IE A A A E NA E E AE E E 193 11 2 General Audio COMMAandS ssssssssssssssssssssssssssersssssssssssssseresssesssssssesereeesssssssseteeeesssesssssttteeessssssssstttteeeesnsssnstt 193 11 2 1 CRSL Call Ringer Level sssssssssssssssssssssssssssseeesssssssssoseseeessesssstsssseeeeessssssssssteetesenestetseereee
238. ntains a single MIN number lt toda gt Type of DA Value between 128 255 according to GSM 03 40 9 1 2 5 If this field is not given and first character of lt da gt is lt toda gt will be 145 otherwise 129 lt length gt Size of message in PDU mode format in octets excluding SMSC data lt mr gt Sent message reference number PDU Message header and contents in PDU mode format See description in CMGW Write Message to Memory Example AT CMGS 064593042 129 gt This is the message body lt CTRL Z gt lt CTRL Z gt ends the prompt text mode and returns to regular AT command mode OK AT CMGF 0 OK AT CMGS 24 gt 079179521201009511FF0B917962543940F20008001400410042004300440045 lt CTRL Z gt CMGS 128 OK Note Any character sent by TE to H330 before H330 has reported a result of AT CMGS operation will abort AT CMGS command execution However if SMS was already sent to network and sending operation was successful the result of operation CMGS lt mr gt will be reported by H330 If after aborting AT CMGS command execution and before result of operation was reported by H330 a second AT CMGS command is executed then the result of the second AT CMGS operation only will be reported by H330 If AT CSCS HEX the SMS cannot be sent CMGS 7 1 21 CSCB Cell Broadcast Messages This command handles the selection of cell broadcast message types and data coding schemes received by the H330 H3
239. ny stored and sent SMS In SMS pdu mode SCA stored in SIM is added to stored SMS and send SMS only when SCA address length coded in PDU equals zero Command Syntax Response Action Remarks Set CSCA lt sca OK Sets service center address stored in SIM gt lt tosca gt or EF SMSp Short message service l parameters lt tosca gt is optional CMS ERROR lt err gt parameter When lt sca gt is prefixed with it indicates that lt tosca gt is set to 145 International number otherwise is 129 local number Read CSCA CSCA lt sca gt lt tosca gt Read command displays lt sca gt and OK lt tosca gt stored in SIM EF SMSp Test The Test command for CSCA is not defined by ETSI H330 Module AT Command User Manual Page 108 of 304 Bs FIBOCOM The following table shows the CSCA parameters lt Parameter gt Description lt sca gt Service Center Address character prefix of lt sca gt indicates lt tosca gt of 145 Minimum 1 and up to 20 characters where each character is represented by semi octets excluding character If lt sca gt contains an odd number of digits bits 4 to 7 of the last octet shall be filled with an end mark coded 1111 lt tosca gt Type of service center address lt tosca gt of 129 is mostly use for local number and 145 for International lt tosca gt of 129 is default value lt tosca gt values are in ra
240. o TE in the case of certain events occurring in the Packet Domain MT or the network Read CGEREP CGEREP lt mode gt The read command returns the current lt bfr gt value of lt mode gt and lt bfr gt parameters OK H330 Module AT Command User Manual Page 240 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test CGEREP CGEREP list of supported lt mode gt s list of The test command lists the supported values for lt mode gt and for lt bfr gt supported lt bfr gt s OK The following table shows the CGEREP parameters lt Parameter gt Description lt mode gt 0 buffer unsolicited result codes in the MT if MT result code buffer is full the oldest ones can be discarded No codes are forwarded to the TE 1 discard unsolicited result codes when MT TE link is reserved e g in on line data mode otherwise forward them directly to the TE 2 buffer unsolicited result codes in the MT when MT TE link is reserved e g in on line data mode and flush them to the TE when MT TE link becomes available otherwise forward them directly to the TE lt bfr gt 0 MT buffer of unsolicited result codes defined within this command is cleared when lt mode gt 1 or 2 is entered 1 MT buffer of unsolicited result codes defined within this command is flushed to the TE when lt mode gt 1 or 2 is entered OK response shall be given before fl
241. odule AT Command User Manual Page 23 of 304 Bs FIBOCOM 4 Modem Control and Status 4 1 Modem Register Commands The H330 holds certain data items in selected memory space named Software Registers S registers and Modem Registers Some of these registers are used as bitmaps where one register holds more than one data item All S registers can be accessed using the S command described in S Bit Map Registers Some registers can also be accessed using dedicated commands detailed below 4 1 1 V H330 Response Format This command determines the response format of the data adapter and the contents of the header and trailer transmitted with the result codes and information responses This command also determines whether the result codes are transmitted in a numeric or an alphabetic verbose form The text portion of information responses is not affected by this setting The following table shows the effect that setting this parameter has on the format of information text and result codes vo Vi Information Responses lt ATVO gt lt cr gt lt lf gt lt ATV1 gt lt cr gt lt lf gt 0 OK lt numeric code gt lt cr gt lt verbose code gt lt cr gt lt lf gt 1 CONNECT 2 RING 3 NO CARRIER 4 ERROR 5 NO DIALTONE 6 BUSY 7 NO ANSWER Command Syntax Response Action Remarks Set ATV lt value gt OK The Set command sets the format bi of information respo
242. odule AT Command User Manual Page 74 of 304 Bs FIBOCOM Note Whena mobile originated call is routed to PSTN PABX no ALERT indication is prompted Example AT CLCC CLCC 0 1 OK AT CLCC CLCC 1 0 0 0 0 01 256316830 129 OK AT CLCC CLCC 0 OK AT CLCC 1 Example with unsolicited indication OK ATD055490698 OK CLCC 1 0 2 0 0 055490698 129 CLCC 1 0 3 0 0 055490698 129 OK CLCC 1 0 0 0 0 055490698 129 ATH NO CARRIER OK CLCC 1 0 6 0 0 055490698 129 5 4 3 MCST Call Status Messages This command displays the current state of the call processing and also enables disables the unsolicited indication of any change in the call processing state Command Syntax Response Action Remarks Set MCST OK The Set command Enables Disables the lt n gt k unsolicited call status messages CME ERROR lt err gt Read MCST MCST lt state gt The Read command returns the current OK call processing state H330 Module AT Command User Manual Page 75 of 304 Bs FIBOCOM When a change in call state occurs and the MCST is set to n 1 the H330 will give the following indication MCST lt state gt MCST Parameters The following table shows the MCST parameters lt Parameter gt Description lt n gt 0 Disable MCST unsolicited indication 1 Enable MCST unsolicited indication lt state gt 1 Idle call state 2 Single incoming call
243. of proactive commands by SIM APPL from the SIM card 8 Disable fetching of proactive commands by SIM APPL from the SIM card 15 Hardware reset Need power cycle the module lt STK_mode gt 0 Inactive state 6 Enables the SIM toolkit interface and fetching of proactive commands by SIM APPL from the SIM card 7 Disables the SIM toolkit interface and fetching of proactive commands by SIM APPL from the SIM card 8 Disable fetching of proactive commands by SIM APPL from the SIM card Example AT CFUN CFUN 0 1 4 6 7 8 15 OK AT CFUN CFUN 1 0 OK AT CFUN 4 OK AT CFUN CFUN 4 Power cycling AT CFUN CFUN 4 0 AT COPS COPS 2 Disable phone transmit and receive RF circuits H330 Module AT Command User Manual Page 183 of 304 Bs FIBOCOM OK AT CFUN 1 Enable phone transmit and receive RF circuits through 1 OK OK AT CFUN CFUN 1 0 OK AT COPS COPS 0 0 CHINA MOBILE OK 10 2 3 CPWROFF Switch off MS This command allows to switches off the H330 shutdown the system Command Syntax Response Action Remarks Set AT CPWROFF OK Shutdown the system or CME ERROR lt error gt Test AT CPWROFF OK 10 2 4 MMAD Query and Monitor ADC Value This command intends to query and monitor ADC value H330 supports 2 ADC channel converter This command returns the current ADC values for the requested channel The values received from the first converter represent t
244. ompatible with short message protocol state 99 Information element non existent or not implemented 111 Protocol error unspecified 127 Interworking unspecified 128 Telematic interworking not supported 129 Short message type 0 not supported 130 Cannot replace short message 143 Unspecified TP PID error 144 Data coding scheme alphabet not supported 145 Message class not supported 159 Unspecified TP DCS error 160 Command cannot be actioned 161 Command unsupported 175 Unspecified TP Command error 176 TPDU not supported 192 SC busy 193 No SC subscription 194 SC system failure 195 Invalid SME address 196 Destination SME barred 197 SM Rejected Duplicate SM 198 TP VPF not supported H330 Module AT Command User Manual Page 300 of 304 Bs FIBOCOM 199 TP VP not supported 208 SIM SMS storage full 209 No SMS storage capability in SIM 210 Error in MS 211 Memory Capacity Exceeded 212 SIM Application Toolkit Busy 213 SIM data download error 224 TP_FCS_APPL_ERR_START 254 TP_FCS_APPL_ERR_STOP 255 TP_FCS_UNSPECIFIED 300 ME failure 301 SMS service of ME reserved 302 operation not allowed 303 operation not supported 304 Invalid PDU mode param 305 invalid text mode parameter 310 SIM not inserted 311 SIM PIN required 312 PH SIM PIN necessary 313 SIM failure 314 SIM busy 315 SIM wrong
245. on is routed to the terminal using the unsolicited result code CMTI lt mem gt lt index gt lt mt gt 2 SMS DELIVER except class2 SMS are routed directly to the TE using H330 Module AT Command User Manual Page 115 of 304 Bs FIBOCOM the unsolicited result code CMT lt alpha lt length gt lt CR gt lt LF gt lt pdu gt in PDU mode or CMT lt oa gt lt alpha gt lt scts gt lt tooa gt lt fo gt lt pid gt lt dcs gt lt sca gt lt tosca gt lt length gt lt CR gt lt LF gt If ME has its own display device then class 0 SMS and SMS in the message waiting indication group discard message may be copied to both ME display and to terminal In this case ME shall send the acknowledgement to the network Class 2 SMSs and messages in the message waiting indication group storage message result in indication as defined in lt mt gt 1 Class 3 SMS DELIVERs are routed directly to terminal using unsolicited result codes defined in lt mt gt 2 Messages of other data coding schemes result in indication as defined in lt mt gt 1 lt bm gt 0 No CBM indications are routed to the terminal default if CBM is stored in RAM NVRAM by ATC DR an indication of memory location is routed to DTE unsolicited result code CBMI lt mem gt lt index gt new CBMs are routed directly to the terminal using unsolicited result code CBM lt length gt lt CR gt lt LF gt lt pdu when PDU mode
246. on socket 1 prior to sending socket should be activated by the mipopen command MIPSETS 0 OK AT MIPSETS 2 400 MIPSETS 0 OK AT MIPSETS Asks the H330 to accumulate 400 bytes on socket 2 prior to sending MIPSETS 1 4 1 2048 0 1000 OK AT MIPSETS H330 Module AT Command User Manual Page 252 of 304 Bs FIBOCOM MIPSETS 1 200 0 Information provided only for active sockets MIPSETS 2 400 0 Information provided only for active sockets OK AT MIPSETS 1 200 50 Asks the H330 to send all accumulated data after 50 msec of receiving data in mipsend command MIPSETS 0 OK AT MIPSETS MIPSETS 1 200 50 MISETS 2 400 0 OK 14 5 MIPDSETS Set Size and Timeout for Output Data This command causes the H330 to set a max length and time span when send received data to TE The max length means the data which H330 send to TE must less than this length Time span is used to define interval of time between two package when send data to TE Command Syntax Response Action Remarks Set MIPDSETS lt Sock OK Time span is et_ID gt lt Size gt lt Ti t defined in me span gt l milliseconds ERROR MIPDSETS lt err gt Read MIPDSETS MIPDSETS lt Socket_ID gt lt Current Size Settings gt lt Time span gt OK For all ACTIVE sockets Test MIPDSETS MIPDSETS 1 4 list of supported lt size gt s list of supported lt Timespan gt s OK The following table
247. one Effect This command reduces the microphone audio input that is routed to the selected speaker so that people speaking will hear themselves talking Command Syntax Response Action Remarks Set ATS94 lt n gt OK The Set command sets the sidetone status or CME ERROR lt err gt Read ATS94 lt n gt The Read command returns the OK sidetone status The following table shows the S94 parameters lt Parameter gt Description lt n gt 0 7 Sidetone range 0 is lowest sidetone not mute The default value is 004 H330 Module AT Command User Manual Page 195 of 304 Bs FIBOCOM 11 2 5 S96 Echo Cancelling This command suppresses a large amount of the output sound picked up by the input device cancels all echo Command Syntax Response Action Remarks Set ATS96 lt n gt OK The Set command sets the echo cancelling status or CME ERROR lt err gt Read ATS96 lt n gt The Read command returns the echo OK cancelling status The following table shows the S96 parameters lt Parameter gt Description lt n gt 0 7 echo cancelling range 0 is lowest echo cancelling not mute The default value is 004 11 2 6 CALM Alert Sound Mode This command handles the selection of the H330 s alert sound mode The value of the command is saved after a power cycle Command Syntax Response Action Remarks Set CA
248. ontext can take up to 40 seconds If use AT MIPCALL 1 APN to activate PDP The cid 1 can not be actived If use AT MIPCALL 1 cid to activate PDP The APN must be set by AT CGDCONT command The following table shows the MIPCALL parameters lt Parameter gt Description operation 0 disconnect a link 1 establish GPRS link lt status gt O Disconnect 1 Connected APN APN of service provider in quotation marks Contact your service provider fordetails cid 1 10 set by cgdcont Local IP address IP address given by server after PPP negotiation H330 Module AT Command User Manual Page 246 of 304 Bs FIBOCOM Example AT MIPCALL 1 internet OK MIPCALL 1 123 145 167 230 AT MIPCALL 0 OK 14 2 MIPOPEN Open a Socket UDP or TCP The terminal hangs up the link Connecting the provider Orange and getting an IP This command causes the H330 module to initialize a new socket that waits for a connection from a remote machine or opens a common connection with a remote side according to received parameters Each socket allocates two accumulating buffers 2048 bytes for sending and 8192 bytes for receiving The mipopen command returns a MIPOPEN unsolicited event to indicate that the opration is success or not and if any error occurs after a socket was opened a usolictited event MIPSTAT would be send Note This command will return in 60 sec when DNS is error
249. onvert the home units used in CAOC CACM and CAMM into currency units Command Syntax Response Action Remarks Set CPUC lt OK The Set command sets the price per currency gt 4CME ERROR lt err gt unit and the currency table SIM PIN2 is lt ppu gt lt required The new value is retained passwd gt after a power cycle Read CPUC CPUC The Read command displays the lt currency gt lt ppu gt current price per unit and currency OK table Test CPUC OK The Test command indicates whether the CPUC command is functioning The following table shows the CPUC parameters lt Parameter gt Description lt currency gt Currency code character set 3 characters defined by CSCS command Refer to CSCS Select Terminal Character Set If the string begins with an alphanumeric character it may be entered with or without quotation marks for example GBP DEM lt ppu gt Price per unit A dot is used as a decimal separator precision of 1 1000 15 digit maximum for example 2 667 See notes below lt passwd gt SIM PIN2 password Maximum string length is 8 characters If this value is exceeded the command terminates in an error If PIN2 is incorrect CME ERROR incorrect password is displayed Example AT CPUC OK AT CPUC GBP 0 125 2222 OK AT CPUC CPUC GBP 0 125 OK H330 Module AT Command User Manual Page 82 of 304 Bs FIBOCOM Note
250. or PUK This command will return error if SIM is not inserted Command Syntax Response Action Remarks Read AT TPI TPIN lt chv1 gt N lt unb1_chv1 gt lt chv2 gt lt unb1_chv2 gt or CME ERROR lt err gt H330 Module AT Command User Manual Page 146 of 304 Bs FIBOCOM The following table shows the TPIN parameters lt Parameter gt Description lt chv1 gt Number of remaining PIN attempts lt chv2 gt Number of remaining PIN2 attempts lt unbl_chv1 gt Number of remaining PUK attempts lt unbl_chv2 gt Number of remaining PUK2 attempts Example AT TPIN TPIN 3 10 3 10 OK AT CPIN 7777 CME ERROR incorrect password AT TPIN TPIN 2 10 3 10 OK 8 1 5 CPWD Change Password This command sets a new password for the facility lock The password can only be changed once the required facility is enabled by the CLCK command A password can be changed only if the provided password lt oldpwd gt has been verified The entered password lt newpwd gt must also comply to the password rules The facility value lt fac gt is not case sensitive In the password value letters are not allowed lt fac gt lt pwdlength gt s OK or CME ERROR lt err gt Command Syntax Response Action Remarks Set AT CPWD lt fa OK Cr PNN or Set a new password for the facility lock newpwd gt CME ERROR lt err gt Rea
251. ows the MHUP parameters lt Parameter gt Description lt cause gt Cause description send to the NW in the disconnect message 1 Unassigned unallocated number 16 Normal call clearing 17 User busy 18 No user responding 27 Destination out of order 31 Normal unspecified lt call_id gt Index of the call id same as lt idx gt in CLCC command 0 All calls default 1 7 Specific call id Example H330 Module AT Command User Manual Page 71 of 304 Bs FIBOCOM AT MHUP MHUP 1 16 17 18 27 31 0 7 OK AT MHUP 16 3 Hung up call 3 and send cause Normal call clearing OK NO CARRIER AT MHUP 17 Hung up all calls and send cause User busy OK NO CARRIER AT MHUP 17 0 Hung up all calls and send cause User busy OK NO CARRIER 5 4 Call Status Messages 5 4 1 CPAS Phone Activity Status This command displays the current activity status of the H330 like call in progress or ringing Command Syntax Response Action Remarks Execute Rea AT CPAS CPAS lt pas gt The Execute and Read d OK commands return the activity status lt pas gt of the or H330 They can be used to CME ERROR lt err gt interrogate the H330 Test AT CPAS CPAS list of supported lt pas gt s OK The following table shows the CPAS parameters lt Parameter gt Description lt pas gt 0 Ready The H330 allows commands from th
252. pe gt lt satype gt Field not used Value is always 128 unknown type of sub address octet in integer format lt alpha gt Name of the calling party if provided by the network lt CLI validity gt The Validity of the Calling Line Identity presentation O CLI valid 1 CLI has been withheld by the originator 2 CLlis not available due to networking problems or limitations of the originating network H330 Module AT Command User Manual Page 54 of 304 Bs FIBOCOM Example AT CLIP CLIP 0 1 CLI presentation is disabled by the H330 0 and is enabled by the network 1 OK AT CLIP 1 OK Example CLIP indication incoming call RING CLIP 13510503472 129 0 Example CLIP indication with restricted CLI AT CRC 1 OK incoming call caller restricted the CLI presentation used AT CLIR CRING VOICE CLIP 128 128 1 5 3 9 CCWA Call Waiting Command This command controls the Call Waiting supplementary service including the settings and the queries of the H330 and the network When the Call Waiting indication is enabled by the H330 and there is a waiting call a CCWA indication is sent from the H330 to the terminal The indication will appear one time Note The H330 supports only one of the services at a time Voice or Data Multiparty is a voice only functionality H330 Module AT Command User Manual Page 55 of 304 Bs FIBOCOM A CCWA indication is sen
253. peration fails 1 operation success Read FTPNOOP ERROR Not supported Test FTPNOOP ERROR Not supported Example AT FTPNOOP FTPINFO NOOP OK FTPINFO 200 NOOP command successful FTPNOOP 1 15 16 FTPSTOR Store File on Remoter Server This command makes the server receive a file from data connection The data end of transmission character of this command is hexadecimal value 0 x03 If the data to be transferred is hexadecimal value 0 x03 and 0 x10 then escape characters 0 x10 must be added in front For example send hexadecimal 03 10 11 03 then should send 10 03 10 10 11 10 03 Note FTPSTOR command makes the server receive the data transmitted by data connection and store the data as file on the server site If the specified file in the path name already exists on the server site then this file will be replaced by transmitted data otherwise a new file will be created Command Syntax Response Action Remarks Set _name gt l FTPSTOR lt file lt file_type gt L lt Offset gt OK FTPSTOR lt result gt or ERROR lt error_code gt lt file_name gt is a complete qualified path and file name on the server site lt Offset gt is the file offset address already exists on the server this means the server support file transfer resume The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success 2 connec
254. perature value for unsolicited report Default value 0 Celsius Setting corresponding lt Low gt and lt High gt temperature boundaries for lt Report gt 3 only Example AT MTSM Test the range of the parameters MTSM 0 3 6 9 1 255 40 125 H330 Module AT Command User Manual Page 186 of 304 Bs FIBOCOM OK AT MTSM 1 Set to read for once the current temperature measurement MTSM 35 Current temperature is 35 Celsius degree OK AT MTSM 2 5 Set to unsolicited temperature reports to TE for every 5 seconds OK MTSM 10 Current temperature measure report 10 Celsius MTSM 5 Unsolicited temperature report 5 Celsius after 5 seconds MTSM 7 Unsolicited temperature measure report 7 Celsius after 10 seconds MTSM 20 Unsolicited temperature measure report 20 Celsius after 15 seconds MTSM 50 Unsolicited temperature measure report 50 Celsius after Nx5 seconds AT MTSM 0 Set to stop the unsolicited report OK AT MTSM 3 30 10 40 Set to out off boundary 10 to 40 Celsius unsolicited reports for every 30 seconds OK MTSM 20 Unsolicited current report out off the Low boundary MTSM 12 Unsolicited report out off the Low boundary after 30 seconds MTSM 47 Unsolicited report out off the High boundary after Nx30 seconds AT MTSM Read the current setting MTSM 3 30 10 40 OK AT MTSM 0 Set to stop the unsolicited report OK A
255. performed on the basis of the recommended default setting of the sub parameter Denotes a comment and should not be included in the command 2 4 2 Command Structure Each AT command has the AT or at prefix string except the commands A and H330 Module AT Command User Manual Page 14 of 304 Bs FIBOCOM Each AT command has the suffix lt CR gt except the commands A and Example AT CSQ lt CR gt ATS24 lt CR gt An AT command line may contain one or more commands Delimiters are used to separate the commands from each other The delimiter is either a semicolon or none meaning space basic commands Example ATSO 1V1Q0E0 lt CR gt AT IFC 0 0 ICF 3 4 CNMI 2 1 0 0 0 lt CR gt 2 4 3 Results Code Structure By default the H330 responds with verbose response codes The results code prefix is lt CR gt lt LF gt The results code suffix is lt CR gt lt LF gt Example lt CR gt lt LF gt CSQ 99 99 lt CR gt lt LF gt lt CR gt lt LF gt OK lt CR gt lt LF gt The unsolicited results code is same as the Results code 2 5 Command Syntax Execute command syntax AT Xxx ATXxx ATXXx Parameter set command syntax AT xxx lt Value gt ATxxx lt Value gt Parameter read Command syntax AT Xxx ATXxx Parameter test Command syntax AT Xxx ATXxx lt Value gt consists of either a numeric constant or a string constant lt compound_value
256. ponse was an Echo Reply message or a gateway router in a path of Echo Request message passage for any other ICMP response message lt type gt The first octet of the ICMP header is a ICMP type field which specifies the format of the ICMP message Referto IETF RFC 792 for lt type gt valid values lt code gt The reasons for the non delivery of a packet are described by code field value of ICMP header Every lt type gt has its own defined lt code gt values Refer to IETF RFC 792 for lt code gt valid values lt RTT gt Specifies Round Trip Time RTT measured in milliseconds This parameter will be reported in command response only if Echo Reply message was received H330 Module AT Command User Manual Page 267 of 304 Bs FIBOCOM Note Ping request is being executed from the moment the valid AT MPING set command was received by H330 until MPINGSTAT unsolicited report with lt status gt equal either to 0 or 2 is sent to DTE or ping request execution was aborted with AT MPING 0 command Refer to description of MPINGSTAT unsolicited response for details In some cases the reply message for an Echo Request message might be not an Echo Reply messages but rather some other ICMP message which is reporting an error in datagram processing For purpose of reporting an exact type of response for sent Echo Request message unsolicited response includes lt type gt and lt code gt fields The first octet of th
257. r 0 255 0 S2 Sets gets escape code character 1 255 43 3 Sets gets carriage return code character 0 127 13 S4 Sets gets line feed code character 0 127 10 S5 Sets gets command line editing character 0 127 8 backspace S6 Sets gets the amount of time in seconds that the 2 10 2 DCE waits between connecting to the line and dialing when dial tone is not implemented or enabled S7 Sets the number of seconds in which connection 1 255 60 must be established before the call is disconnected S8 Sets get the amount of time in seconds that the 0 255 2 DCE shall pause during dialing when a dial modifier is encountered in a dial string 12 Sets get guard time in units of 50 msec for the 0 255 20 Note V 25 ter standard Example ATSO 000 OK ATSO 3 OK ATSO 003 OK H330 Module AT Command User Manual SO Auto Answer should work regardless of the DTR HW line state This is a deviation from the ITU Page 28 of 304 Bs FIBOCOM 4 1 6 S2 This command handles the selection of the escape characters which are stored in S Register 2 and specifies the escape character used in CSD connections Command Syntax Response Action Remarks Set S2 lt esca OK The Set command sets the CSD escape pe_charac CME ERROR lt err gt character value if all parameters are ter gt valid Read S2 lt escape_character gt The Read command displays the OK currently defined escape character for CSD con
258. ractive 3 background Other values are reserved lt Maximum bitrate UL gt A numeric parameter that indicates the maximum number of kbits s delivered to UMTS up link traffic at a SAP As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt Anumeric parameter that indicates the maximum number of kbits s delivered by UMTS down link traffic at a SAP As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 Anumeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate DL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQMIN 32 refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery order gt Anumeric parameter that indicates whether the UMTS bearer shall provide in sequence SDU delivery or not 0 no 1 yes Other values are reserved lt Maxi
259. re is an active voice call and the terminal sends another ATD voice call command to the H330 H330 Module AT Command User Manual Page 44 of 304 Bs FIBOCOM the active call is put on hold and the new number is called Command Response Action ATD lt number gt f VOICE CALL 1st response Voice call place begins OK 2nd response Voice call connected OK DATA 1st response only Data call connected CONNECT When MO call fails 1 Connection Failure NO CARRIER or BUSY or NO ANSWER 2 General Failure ERROR 3 Security reason such as SIM not present OPERATION NOT ALLOWED 4 Unknown reason UNKNOWN CALLING ERROR The following table shows the D parameters lt Parameter gt Description lt number gt Valid phone digits are 0123456789 The following characters are ignored A B CD and lt space gt semicolon When given after lt number string gt a voice call is originated to the given address otherwise a data call is originated The control of supplementary services through the Dial command is not supported as these are controlled through the specific supplementary service commands CCFC CLCK and so on Initiating a GPRS connection is done through ATD 99 as described in D 99 Example atd44345678 VOICE call with semicolon OK OK atd44345678 DATA call without semicolon CONNECT Move to online Data state H330 Module AT Command U
260. red by UMTS down link traffic at a SAP As an example a bitrate of H330 Module AT Command User Manual Page 231 of 304 Bs FIBOCOM 32 kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to 0 the subscribed value will be requested This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt Anumeric parameter that indicates the guaranteed number of kbits s delivered to UMTS up link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to 0 the subscribed value will be requested This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 Anumeric parameter that indicates the guaranteed number of kbits s delivered by UMTS down link traffic at a SAP provided that there is data to deliver As an example a bitrate of 32kbit s would be specified as 32 e g AT CGEQREQ 32 If the parameter is set to O the subscribed value will be requested This parameter should be provided if the Traffic class is specified as conversational or streaming refer 3GPP TS 24 008 subclause 10 5 6 5 lt Delivery order gt
261. rent calls CLCC lt idx gt lt dir gt lt call state gt lt mode gt lt mpty gt lt number gt lt type gt OK Read AT CLCC CLCC lt state gt The Read command OK returns the call status or CME ERROR lt err gt H330 Module AT Command User Manual Page 73 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CLCC CLCC List of supported lt state gt s OK or CME ERROR lt err gt The following table shows the CLCC parameters lt Parameter gt Description lt state gt 0 Disable CLCC unsolicited indication 1 Enable CLCC unsolicited indication The default value is 0 lt idx gt Integer type call identification number lt dir gt 0 Mobile originated call MO 1 Mobile terminated call MT lt call state gt The state of the call 0 Active 1 Held 2 Dialing MO call 3 Alerting MO call 4 Incoming MT call 5 Waiting MT call 6 Released lt mode gt Bearer Teleservice 0 Voice Call 1 Data lt mpty gt Multiparty status 0 Call is not part of a multiparty call 1 Call is one of multiparty call parties lt number gt Phone number in the format specified by lt type gt Contains a string of up to 32 characters lt type gt Phone number display format Type of address octet in integer format refer to GSM 04 08 subclause 10 5 4 7 129 Local number 145 International number with access character H330 M
262. ries are now lt direct gt lt ac or cy gt CME ERROR lt err gt active for the different audio features The lt features gt field is only used for outputs direct 1 Read MAPATH MAPATH 1 mode The Read command returns the in lt accy gt lt CR gt lt LF gt MA active input audio accessory and PATH 2 mode the output accessory for each out lt accy gt lt CR gt lt LF gt OK feature Test MAPATH MAPATH list of The Test command returns the supported directions list supported audio directions of supported accessories input output accessories and OK features H330 Module AT Command User Manual Page 199 of 304 Bs FIBOCOM The following table shows the MAPATH parameters lt Parameter gt Description lt direct gt 1 Audio channel input H330 2 Audio channel output from H330 lt accy gt Audio channel input module 1 1 channel MIC MIC Default 2 2 channel AUXI AUXI Audio channel output from H330 1 1 channel SPK SPK Default 2 2 4 channel AUXO AUXO 3 Both 1 and 2 Example at mapath MAPATH 1 1 MAPATH 2 1 OK at mapath 2 2 Swith to 2 audio channel OK at mapath 1 2 OK at mapath MAPATH 1 2 MAPATH 2 2 OK 11 2 11 MAVOL Volume Setting This command enables you to determine a volume level for a particular feature via a particular accessory The gain levels are saved in NVM Therefore upon power up th
263. rk provisioning state of the CLI presentation OK H330 Module AT Command User Manual Page 53 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Test AT CLIP CLIP 0 1 The Test command returns the Set OK command options 0 1 5 3 8 CLIP Indication When the CLI presentation indication is enabled by the H330 lt n gt 1 this unsolicited indication is sent to the terminal after the RING indication CLIP lt number gt lt type gt lt subaddr gt lt satype gt lt alpha gt lt CLI validity gt The following table shows the CLIP parameters lt Parameter gt Description lt n gt Enables disables the CLI presentation indication after the ring indication 0 Disable CLI presentation 1 Enable CLI presentation The default value is 0 lt m gt Shows the subscriber CLIP service status in the network 0 CLIP not provisioned 1 CLIP provisioned 2 Unknown for example no network and so on lt number gt Calling line number The number format is specified by lt type gt lt type gt Type of address octet in integer format 145 Default when the dialing string includes the international access code character 129 Default when making a local call 128 Type of number is unknown usually the output when the number itself is unknown lt subaddr gt NULL field not used String type subaddress of format specified by lt saty
264. rmation screen 12 Neighbor Cells Summary screen 13 Re selection screen 14 Hopping Information screen H330 Module AT Command User Manual Page 168 of 304 Bs FIBOCOM 15 PDP1 Context Information screen 16 PDP2 Context Information screen 17 PDP3 Context Information screen 18 PDP4 Context Information screen 19 Serving Cell paging parameters 20 Optional SYSINFOs MCELL Indication After AT MCELL command the information about the Cellular Network will return back by this MCELL indication format few senconds later MCELL lt screen_title gt lt CR gt lt LF gt lt screen_info gt lt CR gt lt LF gt The following table shows the MCELL parameters lt Parameter gt Description lt screen_title gt The requested screen title is written on the first line of each screen lt screen_info gt The requested screen information lt screen title gt Description lt screen num gt Serving Idle PI Idle Packet Idle mode Serving Cell Information 1 screen Serving CS TBF Circuit Switched mode Serving Cell Information 2 screen Serving Misc Idle Packet Idle mode Miscellaneous Information 3 screen Uplink Transfer Dedicated TBF modes Uplink Data Transfer screen 4 Downlink Transfer Dedicated TBF modes Downlink Data Transfer 5 screen Adjacent Cell x Neighbor Cell Information screen 6 11 x index cell Neighbors Neighbor
265. rnal CODEC is in slave mode 1 module is in slave mode external CODEC is in master mode lt tran_mode gt Data Transimisson Mode 0 12S mode 1 PCM mode lt sample gt Sampling rate 0 8k 1 16k 2 24K 3 32K 4 44 1K lt width gt Word width 0 16BIT 1 24BIT 2 32BIT Example AT MAI2SY 0 0 0 0 set the module to master mode 12S sampling rate to 8K width to 16BIT OK AT MAI2SY MAI25SY 0 0 0 0 OK AT MAI2SY MAI2SY 0 1 0 1 0 1 2 3 4 0 1 2 OK Note e AT MAIDIGITAL set to 0 MAI2SY is invalid e The setting is invalid when calling H330 Module AT Command User Manual Page 295 of 304 Bs FIBOCOM 17 Error Code The list below is a draft List and is still TBD 17 1 CME Error Parameter Description lt Err gt 0 phone failure 1 no connection to phone 2 phone adaptor link reserved 3 operation not allowed 4 operation not supported 5 PH SIM PIN required 6 PH FSIM PIN required 7 PH FSIM PUK required 10 SIM not inserted 11 SIM PIN required 12 SIM PUK required 13 SIM failure 14 SIM busy 15 SIM wrong 16 incorrect password 17 SIM PIN2 required 18 SIM PUK2 required 19 incorrect PUK1 20 memory full 21 invalid index 22 not found 23 memory failure 24 text string too long 25 invalid characters in text string 26 dial string too long 27 invalid characters in dial string 30 no network service
266. rt 0 for incoming connection Protocol Type of protocol stack 0 TCP 1 UDP State 0 Inactive 1 Active Note It s recommended not to use port numbers below 1024 those numbers are reserved for OS use Example H330 Module AT Command User Manual Page 273 of 304 Bs FIBOCOM Opening socket 1 in Online Data Mode using TCP protocol from port 1104 designation IP 123 245 213 012 designation port 1124 AT MIPODM 1 172 90 237 21 1124 0 OK MIPODM 1 1 Enter invalid command format AT MIPODM ERROR Check opened in Online Data Mode socket state when H330 is pseudo command mode AT MIPODM MIPODM 1 1 OK Listen socket over TCP AT MIPODM 1 0 0 0 0 0 0 Listens to any port at any IP OK MIPODM 1 1 122 221 32 64 1200 Remote side connected to the listen socket 14 18 MIPXOFF Flow Control Xoff This command is the unsolicited response that the H330 sends to the terminal to stop sending data when it does not have enough memory to process new MIPSEND requests The H330 uses the accumulating buffer prior to pushing data into the protocol stack This memory resource is protected by a Xoff_upper watermark Event MIPXOFF lt Socket ID gt Example MIPXOFF 1 The H330 detects that the accumulating buffer 1 has reached its Xoff watermark From this point the terminal is not allowed to send data until it receives the MIPXON command 14 19 MIPXON Flow Control Xon Thi
267. rwise the message is sent to the DA it was stored with if any was entered If no DAis found an error occurs When the given index is an incoming message index the header settings will be as follows H330 Module AT Command User Manual Page 132 of 304 Bs FIBOCOM lt first octet gt will be SMS SUBMIT and VPF relative The TP RP and TP UDHI settings will be taken from the incoming message s first octet lt vp gt will be set to the default value 167 as defined in 03 40 lt sca gt lt tosca gt lt pid gt and lt dcs gt will be set according the incoming message parameters If lt da gt and or lt toda gt are not given by the command the lt oa gt and lt tooa gt will be set instead Command Syntax Response Action Remarks Set CMSS lt inde CMSS lt mr gt The Set command sends a message from x gt L lt da gt lt tod oi storage to the network a gt CMS ERROR lt err gt The following table shows the CMSS parameters lt Parameter gt Description lt index gt 1 352 Index in storage of the message to be sent lt da gt Destination address in quoted string This field contains a single phone number lt toda gt Type of DA Value between 128 255 according to GSM 03 40 9 1 2 5 If this field is not given and first character of lt da gt is lt toda gt will be 145 otherwise 129 lt mr gt Sent message reference number Example AT CMSS 7 CMSS 1
268. ry of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt lt CR gt lt LF gt CGEQMIN lt cid gt lt Traffic class gt lt Maximum bitrate H330 Module AT Command User Manual Page 225 of 304 Bs FIBOCOM UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt Test AT CGEQMIN CGEQMIN lt PDP_type gt list of supported lt Traffic class gt s list of supported lt Maximum bitrate UL gt s list of supported lt Maximum bitrate DL gt s list of supported lt Guaranteed bitrate UL gt s list of supported lt Guaranteed bitrate DL gt s list of supported lt Delivery order gt s list of supported lt Maximum SDU size gt s list of supported lt SDU error ratio gt s list of supported lt Residual bit error ratio gt s list of supported lt Delivery of erroneous SDUs gt s list of supported lt Transfer delay gt s list of supported lt Traffic handling priority gt s list of supported lt Source statistics descriptor gt s list of supported lt Signalling indic
269. s If text mode CMGF 1 command execution is successful and SMS COMMANDs CMGL lt index gt lt stat gt lt fo gt lt ct gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt fo gt lt ct gt L If text mode CMGF 1 command execution is successful and CBM storage CMGL lt index gt lt stat gt lt sn gt lt mid gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt sn gt lt mid gt lt page gt lt pages gt lt CR gt lt LF gt lt data gt If text mode CMGF 1 command execution is successful and SMS STATUS_REPORTs CMGL lt index gt lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt st gt lt CR gt lt LF gt H330 Module AT Command User Manual Page 126 of 304 Bs FIBOCOM CMGL lt index gt lt stat gt lt fo gt lt mr gt lt ra gt lt tora gt lt scts gt lt dt gt lt st gt In PDU mode CMGF 0 CMGL lt index gt lt stat gt lt alpha gt lt length gt lt CR gt lt L F gt lt pdu gt lt CR gt lt LF gt CMGL lt index gt lt stat gt lt alpha gt lt length gt lt CR gt lt L F gt lt pdu gt Or CMS ERROR lt err gt Test CMGL CMGL list of supported lt stat gt s The Test command lists all the supported lt stats gt The following table shows the CGML parameters
270. s lt CR gt lt LF gt CGTFT lt PDP_type gt list of supported lt packet filter identifier gt s list of supported lt evaluation precedence index gt s list of supported lt source address and subnet mask gt s list of supported lt protocol number ipv4 next header ipv6 gt s list of supported lt destination port range gt s list of supported lt source port range gt s list of supported lt ipsec security parameter index spi gt s list of supported lt type of service tos ipv4 and mask traffic class ipv 6 and mask gt s list of supported lt flow label ipv6 gt s The test command returns values supported as a compound value H330 Module AT Command User Manual Page 243 of 304 Bs FIBOCOM The following table shows the CGTFT parameters lt Parameter gt Description lt cid gt a numeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands lt packet filter identifier gt Numeric parameter value range from 1 to 8 lt source address and subnet mask gt Consists of dot separated numeric 0 255 parameters on the form a1 a2 a3 a4 m1 m2 m3 m4 for lpv4 and al a2 a3 a4 a5 a6 a7 a8 a9 a10 a11 a12 a13 a14 a15 a16 m1 m2 m3 m4 m5 m6 m7 m8 m9 m10 m11 m12 m13 m14 m 15 m16 for lpv6 lt protocol number ipv4 next header ipv6 gt Numeric parameter value range from 0 to 255
271. s Set AT CGEQREQ lt cid gt OK Set command specifies L lt Traffic class gt ERROR a profile for the context identified by the local context identification parameter lt cid gt The specified profile will be stored in the MT and sent to the network only at activation or MS initiated modification of the related context Parameter value ranges for each PDP type are returned on a separate line H330 Module AT Command User Manual Page 229 of 304 Bs FIBOCOM Read AT CGEQREQ CGEQREQ lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source statistics descriptor gt lt Signalling indication gt lt CR gt lt LF gt CGEQREQ lt cid gt lt Traffic class gt lt Maximum bitrate UL gt lt Maximum bitrate DL gt lt Guaranteed bitrate UL gt lt Guaranteed bitrate DL gt lt Delivery order gt lt Maximum SDU size gt lt SDU error ratio gt lt Residual bit error ratio gt lt Delivery of erroneous SDUs gt lt Transfer delay gt lt Traffic handling priority gt lt Source Statistics Descriptor gt lt Signalling Indication gt Read command returns the current settin
272. s information on the supported GPRS OK service states Note This command has the characteristics of both the V 25ter action and parameter commands Therefore it has the Read form in addition to the Execution Set and Test forms H330 Module AT Command User Manual Page 216 of 304 Bs FIBOCOM The following table shows the CGATT parameters lt Parameter gt Description lt state gt Indicates the state of the GPRS attachment 0 Detached 1 Attached Example AT CGATT CGATT 0 1 OK AT CGATT CGATT 0 OK AT CGATT 0 OK 13 2 6 D 99 Request GPRS Service D This command enables the ME to perform the actions necessary for establishing communication between the terminal and the external Packet Data Network PDN The ITU V 25ter D Dial command causes the ME to enter the ITU V 25ter Online Data state and together with the terminal to start the specified layer 2 protocol The ME returns CONNECT to confirm acceptance of the command prior to entering the ITU V 25ter Online Data state No further commands may follow on the AT command line The detailed behavior after the Online Data state has been entered is dependent on the PDP type and is described briefly GPRS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been performed using the CGATT and CGACT commands When the layer 2 protocols have terminated either
273. s are unavailable there is an empty field The list of operators is in the following order home network networks referenced in SIM or active application in the UICC GSM or USIM in the following order HPLMN selector User controlled PLMN selector Operator controlled PLMN selector and PLMN selector in the SIM or GSM application and other networks After the operator list the H330 returns lists of the supported lt mode gt s and lt format gt s These lists are separated from the operator list by two commas H330 Module AT Command User Manual Page 158 of 304 Bs FIBOCOM The following table shows the COPS parameters lt Parameter gt Description lt mode gt Determines whether what is displayed is defined by lt oper gt or is done automatically by the H330 0 Automatic lt oper gt field is ignored 1 Manual lt oper gt field is present 2 De register from network 3 Set only lt format gt lt oper gt field is ignored used for Read command only do not attempt registration deregistration 4 Manual automatic lt oper gt field is present if manual selection fails use automatic mode The default value is 0 lt format gt The operator format type 0 Long alphanumeric 1 Short alphanumeric 2 Numeric The default value is 0 lt stat gt 0 Unknown 1 Available 2 Current 3 Forbidden lt oper gt Operator name displayed The long alphanumeric format can be
274. s command is the unsolicited event that the H330 sends to the terminal when it detects that it has free memory in the accumulating buffer and can process new MIPSEND requests after the MIPXOFF event Event MIPXON lt Socket ID gt Example MIPXON 1 The H330 pushed the data into the protocol stack on socket 1 and is able to handle more data from the terminal H330 Module AT Command User Manual Page 274 of 304 Bs FIBOCOM 15 FTP Command 15 1 FTP Introduction File Transfer Protocol FTP is a standard network protocol used to transfer files from one host to another host provided by TCP IP it is an application protocol of TCP IP protocol which makes it possible for sharing the data among different hosts FTP use C S mode the client can download files and upload files as well Of course FTP gives the user certain authority user can only use it under authority There are many types of FTP Server currently like commonly used SERV U as well as client program like CuteFTP WINDOWS also provided a FTP client program 15 2 FTPOPEN Open a FTP Connection with FTP Server This command is used for opening the connection between the module and FTP Server by sending user and password authentication Note e Only one FTP connection can be in progress each time e After the connection is opened there is going to be a 120 seconds timeout exit if no FTP operation exists Command Syntax Response Action Re
275. s of 10 ms 1 255 The default value is 10 100 ms lt N2 gt Maximum number of retransmissions 0 5 The default value is 3 lt T2 gt Response timer for the DLCO in unit of 10 ms lt T2 gt must be longer than lt T1 gt 2 255 The default value is 30 300 ms lt T3 gt Wake up response timer in seconds 1 255 The default value is 10 lt k gt Reserve for Advanced operation with Error Recovery options H330 Module AT Command User Manual Page 208 of 304 Bs FIBOCOM 13 GPRS 13 1 GPRS Functionality GSM 07 07 defines commands that a TE may use to control a GPRS ME via a non multiplexed character stream interface This places certain limitations on the functionality of the interface For example it is not possible for the ME to send control information to the TE or for the TE to send commands to the ME whilst the interface is in the online data state unless the layer 2 protocol itself supports this feature GSM 07 60 12 However H330 specific escape mechanism DTR is provided to enable the TE to switch the H330 into limited online command state The use of a multiplexed interface GSM 07 10 is not considered here See Multiplexer Feature The H330 specific escape mechanism use DTR as an escape signal following amp D parameters and designed for limited non network related commands This specific mechanism purpose is to give the user a way to retrieve the signal stre
276. se refer to the description of AT amp D 5 1 3 Hanging Up If you are using a communications program use the Hang up or Disconnect AT command in the program to disconnect the call When using computers in the Dumb Terminal mode return to the Command mode by typing the Escape Sequence and then hang up by typing the Hang up command as follows ATH lt Enter gt OK NO CARRIER If the H330 responds with OK and NO CARRIER the dial connection is closed 5 2 Receiving a Data Call ATA lt Enter gt This command instructs the modem to be the answering modem Either party may be the answering or the originating modem but both parties cannot be the same modem at the same time You hear the modem handshake and see the result code CONNECT OK Note e Outgoing Voice Call during CSD Call when switching to Command mode e If using Dial Command to make Outgoing Voice Call currently active CSD Call is dropped and the new Voice Call is generated 5 3 Call Control AT Commands 5 3 1 D Dial Command This command places a DATA VOICE call on the current network The default call type is a data call CSD There must be an explicit request in order to make a VOICE call If a DATA call was originated and answered by the remote side a OK notification is sent to the terminal from the H330 and it moves to the online Data state For more information about call failure should use the AT CEER command Note If the
277. seessseess 13 2 3 AT Commands Protocol uu sessssescsssscsseecsseccsseecssccssseesssecssscesssecsuecesseecsuecesseccsnecssseecssecssseessseesuessueeesueeesneessneesaes 13 24 AT Commands StructUre eessescsssscssescsseecsseecssecsssecssssessscessscesueeesseecsuecesseccsseesssecssseessseesuseesueessueeesueeesseeesneesaes 14 24 1 General Symbols Used in AT Commands Description esesssescsesceseeseccsseecseeessseessneessnseesees 14 2 4 2 COMMANA StrUCtULe cesscsesccseccsescsseesnsecesssessescsseccsseecsseccsccecssecssseesssessueeesuesesueesseccsneecsseessseessessneesuees 14 2 4 3 Results Code Structure ecsescssscssescssecsssecsseecsseesssescsssecsseccsseccsseecssecssseessseesuseesueesuecessecessecesseesseecsnseesaes 15 2 5 COMMMANA ISSVADI s D 15 3 M demD scecccccecescssaeczescecnsscccucscovssrascovesscecsuscssscnsssatscereassecuscotsnssstazsenasdcvetcedaserssetevacsanasczesseaeserasateasvncvatensssstiaseetesueecetscnessstas 17 3 1 CGMI GMI FMI Request Manufacturer ID ssssccsssscccssesccssscsesssececssecessueecssnsccesssecessneecesneecssnseessee 17 3 2 CGMM GMM FMM Request Model ID uuu ssescsssscsssecssescsssecsssecsssccsseccsseccsseesssecssseessseesssessueesneeesseeess 17 3 3 CGMR GMR FMR Request REVISION ssssescsscsescsesessecsseessecssecssecssecssecssecssecssecssecssecssecsneesseesseesseeses 18 3 4 CGSN GSN Request Product Serial Number Identification ssssscsssescsssssecsseccesse
278. ser Manual Page 238 of 304 Bs FIBOCOM lt cid gt s for defined primary contexts lt PDP_type gt list of supported lt d_comp gt s list of supported lt h_comp gt s lt CR gt lt LF gt CGDSCONT range of lt cid gt s list of lt cid gt s for defined primary contexts lt PDP_type gt list of supported lt d_comp gt s list of supported lt h_comp gt s J OK Command Syntax Response Action Remarks Set CGDSCONT OK Set command specifies lt cid gt lt p_cid gt Or PDP context parameter L lt d_comp gt L lt values for a Secondary h_comp gt ERROR PDP context identified by the local context identification parameter lt cid gt Read CGDSCONT CGDSCONT lt cid gt lt p_cid gt Read command returns lt d_comp gt lt h_comp gt the current settings for OK each defined context Test CGDSCONT CGDSCONT range of lt cid gt s list of Test command returns values supported as a compound value The following table shows the CGDSCONT parameters lt Parameter gt Description lt cid gt PDP Context identifier It is a numeric parameter which specifies a particular PDP context definition The parameter is local to the TE MT interface and is used in other PDP context related commands The range of the permitted values is 1 10 lt p_cid gt Primary PDP context identifier It is anumeric parameter which specifies a particular PDP context definition w
279. ser Manual Page 45 of 304 Bs FIBOCOM 5 3 2 D gt Direct Dialing from Phone Books This command places a DATA VOICE call on the current network by dialing directly from the H330 phone book Note e CME ERROR not found is returned when no match is found in an existing phone book e FD phone book supports the wild card character Telephone numbers containing this character cannot be dialed directly from the phone book e CME ERROR Invalid index is returned when entry lt n gt is out of the requested Phonebook range The following table shows a detailed description for the D gt commands Command Detailed Description D gt lt alpha gt Originates a call to a phone number with the corresponding alphanumeric field lt alpha gt The Current Phone Book Set by CPBS is searched for the entry that begins with the alphanumeric pattern lt alpha gt D gt mem lt n gt Originates a call to a phone number in memory phone book mem and stored in entry location lt n gt D gt lt n gt j Originates a call to a phone number from entry location lt n gt in the Current Phone Book Set by CPBS Note Current used memory phone book set read is done through the memory command CPBS CPBS respectively The following table shows the D gt parameters lt Parameter gt Description lt alpha gt String type value which should be equal to an alphanumeric field ina phone book en
280. session to asynchronous command mode the session remains connected 2 Deactivate GPRS and returns to command mode The default value is 2 10 1 7 ICF DTE DCE Character Framing This command determines the local serial port start stop asynchronous character framing used by the DCE when accepting DTE commands and transmitting information text and result codes whenever these are not done automatically Auto detect for framing is not supported Command Syntax Response Action Remarks Set ICF lt format OK The Set command determines the gt L lt parity gt 4CME ERROR lt err gt local serial port start stop character framing Read ICF ICF lt format gt lt parity gt The Read command displays the CME ERROR lt err gt currently selected character framing Test ICF ICF list of supported The Test command displays a list of lt format gt values list of supported lt format gt and lt parity gt supported lt parity gt values values CME ERROR lt err gt H330 Module AT Command User Manual Page 180 of 304 Bs FIBOCOM The following table shows the ICF parameters lt Parameter gt Description lt format gt Determines the number of bits in the data bits the presence or absence of a parity bit and the number of stop bits in the start stop frame 1 8 Data 2 Stop can be set only with lt parity gt 4 2 8 Data 1 Parity 1 Stop can be set with lt parity gt o
281. splay 542 SMS PP Unspecified 543 SMS rejected By SMS CONTROL H330 Module AT Command User Manual Page 302 of 304 Bs FIBOCOM 17 3 TCP IP Error Parameter Description lt Err gt 2000 TCPIP Param wrong 2001 TCPIP not supported in ppp mode 2002 TCPIP dns convert to ip fail 2003 TCPIP socket number limited 2004 TCPIP invalid operation 2005 TCPIP protol error 2006 TCPIP send data too long 2007 TCPIP send data memory failed 2008 TCPIP service not in correct state 2009 TCPIP pdp not defined 2010 TCPIP new socket failed 2011 TCPIP socket bind fail 2012 TCPIP socket connect fail 2013 TCPIP socket send fail 2014 TCPIP socket close fail 2015 TCPIP get socket receive buffer failed 2016 TCPIP receive data failed 2017 TCPIP socket used 2018 TCPIP get send buffer size failed 2019 TCPIP socket send data failed 2020 TCPIP socket send data size limited 2021 TCPIP socket set listening mode failed 2022 TCPIP socket listen fail 2023 TCPIP socket error 2024 TCPIP socket not opened 2025 TCPIP tcp stack confige failed 2026 TCPIP socket no data to send 2027 TCPIP socket send invalid data state 2028 TCPIP socket close client 2029 TCPIP ping error 2030 TCPIP ppp not connected H330 Module AT Command User Manual Page 303 of 304 Bs FIBOCOM 2031 TCPIP mipcall not active 2032 T
282. ssecseccsseecsseessseesssecsuseesueeesneccsneessneccsseessseessseesnseessecs 93 6 1 2 CPBR Read Phone Book Entries essssscsssscssescsssscsseccsseecsseecsseessscesuscesuceessecesneessseccsseccssecssseesneeessees 95 6 1 3 CPBF Find Phone Book Entries sesssssscsssscsssecsseecsseccsseecssecssscessseesuscesueessnecesneessneccssecsssecsnseessseessees 97 6 1 4 CPBW Write Phone Book Entry uu sesssssscsssecssescsseecsseccsseccsseessscesssessusccsnecesseccsneesssecesseessseessseesnsesssees 99 6 1 5 CSVM Set Voice Mail Server on sessssescssescstsecsseccsseecsseccsseessscsssseesseesueecsneessneccsseecssecsssecsuseesneeesneeess 101 6 2 System Date and Time Access COMMAMNAS sssssccseccseecsseecsscessscessscesscesscecsucccssecsssecesseesssecssseesseeesses 102 6 2 1 CCLK Read Set System Date and Time sesssssscsssecssescsssccsseccsseecsseccsseessseesssecssseessseesseeesneeesneeess 102 Fe SIS e E ER N AARRE E ascents 105 7 1 SMS COMIMANAG ssesccsssccseccssessscessecsscesneccsseccsseecsseccssecesseccusecsusecsssessuseesssessuscesueecsuecesneessneccsseesssecsuseesseeesses 105 7 1 1 CSMS Select Message Service sessssscsssecssssesnseecssscsssecsseessseesssececsseessseeseeesseessseccesuecsneecsneeeseesneeests 105 7 1 2 CPMS Preferred Message Storage ssccssssscsssssssssssecsssssessnsecssnssesssseccesneccssnsecssnsceessseeessneeessnseessnees 106 7 1 3 FCMGEF Message Forimat sescssscssecsescseecsesesseessscsssc
283. ssecssscssscasecssscasecssecasecassensecnsesssscasecassesssesseenseenees 107 7 1 4 CSCA Service Center AddreSS sssssssseescsessssssesseeccceesssssssseeeceeessssssssseeeeeeesssssssssteeeeeeesssssssstereeeeessss 108 7 1 5 CSMP Set Text Mode Pararmeter ecsssscsssscssssssseecsssecsseecssssessescsneccssescssecssseessseessessusecsueeesueeesseeese 111 H330 Module AT Command User Manual Page 6 of 304 Bs FIBOCOM 7 1 6 CSDH Show Text Mode Parameters esssssscsssscsssecsssecssscessecesseecsseccsseccssecesscessseessseesssessneesseessseeess 114 7 1 7 CNMI New Message Indications to Terminal sssssssssscsssscsseccsseecsseccsseessseessseesseeesseeesneeesneeess 115 7 18 CNMA New Message Acknowledgment sssssssssssscsseecsssecsssecsseccsseecsseecsseessseessseesuseesneeesueessneeess 118 7 1 9 CMTI Unsolicited Response New SMS DELIVER Receipt INdication essseecsseecseeeeee 120 7 1 10 CMT Unsolicited Response New SMS DELIVER Receipt ssesssssscsseecsseecsseecsseccsseccsseeeseees 120 7 1 11 CBM Unsolicited Response New CB Message ReCEipt essssccsssccseccseecsseccseesseeesneeesseeess 122 7 1 12 CDSI Unsolicited Response New SMS STATUS REPORT INndication essescseccseeeeseees 123 7 1 13 CDS Unsolicited Response New SMS STATUS REPORT Receipt ssescsssecsseecsseecsseeeseees 123 TAAA AECMIGL List MESSAGES exicescccsices cis cceecies cus ccs iceseclbsaus dacbectvscesecub cc psseveceuccussceu
284. ssscssssscsssssecssseccsssecessueecssssecessnecessneeessusecssnseesssseeessneess 46 5 3 3 DL Dial Last Number uu eessssescssescsseccsseccsscccsscessscesssecsusecsuscessscesseccsseesssecsssecsssecsnseesuseesuseesueeesneeesseesses 47 5 3 4 H Hang up Call on eesseessssescsseecssescsssecsseccsssccsseccssecsssecsssecsuscesuscesuscesneccsnsesssecssseesssecsuseesuseesuseesucessneeesnesses 48 5 3 5 A Answer INCOMING Call ou sessssescsseccsssecsseecsseccssecssscesssecsuecesuscesnecesseessseccsseessnecssseessseccuseesssessuseesnseessees 49 5 3 6 CRC Cellular Result Codes and RING CRING Incoming Call Indication eee 50 5 3 7 CLIP Calling Line Identification 0 sssssssssssccssseccssseeccssecccsneccssssccesssccessuecessuscessnseessnseesssseesesneeessues 53 5 3 8 FCLIP INGICATION 00 eeeaessssescsseecsseccsscccsseccsscccsseccssecsssecsuscessseesuscesuscesuscesueecssecesseesssecssseesssecssseesuseesuseesueessees 54 5 3 9 CCWA Call Waiting Command ou esssssecssecsssssseecsseeesseeesuecesseccsseecsseccsseesssecssseessseessseessseesnseessessnecs 55 5 3 10 CCWA Indication oe eeesssescsssecsnseecsecesnsccsseccsneccsnsecesssceusesssecssseesssecsunsessuscesusesuecesseessusecsnseessseessseesscessees 56 5 3 11 CHLD Call Related Supplementary Services Command ou ssescssescsseecsseecsseccsseecsseecseeesnseesees 58 5 3 12 CCFC Call Forwarding Number and Conditions esssssscssscssescsseecsseecsssecsseccsseecsseecseeesnseesses 61 5 3 13 CLIR Calli
285. ssssssssseeeeeeesssssssoseeeeeeeesssssssseseeeeesssssssssteeeee 174 10 1 2 IPR Local Terminal Serial Port Rate sssssssssssssssssssssssessssssssssssssseeesssssssssoseseeesesssussseseseeeesssssssssssrreee 175 10 1 3 8 K RTS CTS Flow Control ssssccvccsscseaccsccsds satasiascalacaiscossscesceandassoseacaessuscabusssnaseacssectuecabvcsen sanneveaconccnencetucs 177 101 4 IEG RTS CTS FlOW Control sscsesiccsiscosssccevcstossescss cvssccdessacassnnassavabecoasesb ERNEA 177 101 5 amp G Circ it 109 BEM AVI OM innon oea aE ERNER EREEREER OS 178 101 6 amp D Circ it 108 Behavior neinni o REA ERE E 179 10 1 7 CFDTE DCE Character Frarminng ssscsssscsssscssesccnssccnssccnesscnsecsnecesssesssscssssesssscsnssesneseeneseeneeseneeees 180 10 2 Other Parameter COMMANGCG sssccsssccsssccsscscsscscssesssecesssesssscenssesnssseneseeneceeneescnsesenecsessesssecssssesseeeenesesses 181 10 2 1 CBC Battery Charger Connection sscssescssscsescssecssescssecssecssecsssecssecesuecesseecsnecessescssecenseesseeess 181 10 2 2 CFUN Shut Down Phone Functionality esssssssseccssscssecssescssseessescsseccsseecssecesseecsnecenseessseess 182 10 2 3 CPWROFF Switch off MS sssssssssssscsssescssseccssssscssnsecssnsecesssecessuecssusesssnsecesssscessusceesuseessnseessaseeseansesess 184 10 2 4 MMAD Query and Monitor ADC Value eessescsssscsseecsssccssescsseccsseccssecssseessseesseeesueecsuseesseeesneeesee 184 10 2 5 MTSM Temperature Se
286. t or ERROR gt lt CR gt lt LF gt Send any data in HEX The data buffer range is 0 lt buffer lt 1400 bytes lt CTRL Z gt ends the prompt HEX mode and returns to regular AT command mode Notes If there is any data in the buffer sent by previous mipsend H330 will reply ERROR to TE Example Socket 2 already open AT MIPSEND 2 gt This is the data in HEX lt CTRL Z gt lt CTRL Z gt ends the prompt HEX mode and returns to regular H330 Module AT Command User Manual Page 255 of 304 Bs FIBOCOM AT command mode OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK Send data at unfixed length data end with timeout Ctrl Z character 0x1A can not be send at this method Command Syntax Response Action Remarks Set MIPSEND lt Socket_ D gt MIPPUSH data length gt MIPSEND or ERROR lt Socket_ID gt lt Status gt lt pushed lt Socket_ID gt lt Status gt lt FreeSize gt After command received H330 will respond gt lt CR gt lt LF gt Send any data without incode The data buffer range is 0 lt buffer lt 2048 bytes After timeout the data will be push automatic and returns to regular AT command mode The default timeout is 12s Notes If there is any data in the buffer sent by previous mipsend H330 will reply ERROR to TE Example Opening socket 2 already AT MIPSEND 2 gt This is the data in HEX lt tim
287. t A numeric parameter which specifies a particular PDP context definition see the CGDCONT and CGDSCONT commands Note After data transfer is complete the MT re enters the command state and the final result code is displayed on TE In error case the final result code NO CARRIER or CME ERROR lt error gt is displayed PS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been performed using the CGATT and CGACT commands If no lt cid gt is given or if there is no matching context definition the MT shall attempt to activate the context with whatever information is available to the MT The other context parameters shall be set to their default values If the activation is successful data transfer may proceed After data transfer is complete and the layer 2 protocol termination procedure has completed successfully the V 250 command state is re entered and the MT returns the final result code OK Example AT CGDATA ppp CONNECT AT CGDATA CGDATA PPP M OPT PPP M HEX M RAW_IP PAD X25 OK 13 2 16 CGDSCONT Define Secondary PDP Context This command is used to define a secondary PDP context by specifying the PDP context parameter values for a lt cid gt local context identification parameter If the command is used only with the one parameter lt cid gt it means that the corresponding PDP context becomes undefined H330 Module AT Command U
288. t Bottom limit to retransmit timeout 100 ms to 1 sec default 500 ms lt max_TO gt Upper limit to retransmit timeout 1 sec to 60 sec default 60 sec lt max_close_delay gt Closing delay required by RFC 793 100 ms to 7500 ms default 7500 ms lt is_nack_ind_req gt NACK ACK TCP indication feature Activating this parameter enables H330 to report the user in case of losing a TCP connection what data was received by the remote TCP layer 0 feature inactive 1 NACK indication active 2 ACK indication active H330 Module AT Command User Manual Page 263 of 304 Bs FIBOCOM Example AT MIPCONF 2 5 10 600 75 2 OK AT MIPOPEN 2 0 66 249 87 99 80 0 OK MIPOPEN 2 1 AT MIPSETS 2 10 MIPSETS 0 OK AT MIPSEND 2 474554202F20485454502F3 12E300D0A486F 73743A207777772E676F6F676C652E63 6 F6DODOAO0DOA MIPPUSH 2 0 40 MIPSEND 2 0 1372 OK MIPXOFF 2 AT MIPSEND 2 474554202F20485454502F3 12E300D0A486F 73743A207777772E676F6F676C652E63 6 F6DODOAODOA MIPSEND 2 1 1372 OK MIPSTAT 2 0 30 MIPXON 2 MIPSTAT 2 0 40 MIPRTCP 2 530 485454502F312E312033303220466F756E640D0A4C6F 6361 74696F6E3A206874 74703A2F2F7777772E676F6F676C652E636F 2E696C2F63 786665 723F633D505245462533443A544D25 334 43131313935 MIPRTCP 2 450 31343833323A5325334467384A63 763 1426A5458472D30636A5926707265763D 2FOD0A5365742D436F6F6B69653A20505245463D49443D3639303762623837353 13862663233373A4
289. t AAA BBB CCC DDD The value can be written in1 2 or 3 digits Destination_Port 0 65535Port of destination site Written in decimal digits H330 Module AT Command User Manual Page 259 of 304 Bs FIBOCOM Example AT MIPPUSH 1 Terminal asks the H330 to flush the buffer in socket 1 was opened using the MIPOPEN command MIPPUSH 1 0 10 10 bytes has been pushed into protocol stack OK 14 9 MIPFLUSH Flush Data from Buffers This command causes the H330 to flush delete data accumulated in its accumulating buffers Command Syntax Response Action Set MIPFLUSH lt Socket_ID gt MIPFLUSH lt Socket_ID gt OK or ERROR Read MIPFLUSH MIPFLUSH lt socket_ID gt OK Test MIPFLUSH MIPFLUSH lt Socket_ID gt OK The following table shows the MIPFLUSH parameters lt Parameter gt Description Socket_ID 1 2 3 4 Number of valid sockets Example AT MIPFLUSH 2 MIPFLUSH 2 OK AT MIPFLUSH 5 ERROR AT MIPFLUSH MIPFLUSH 1 2 OK Socket number 2 was previously opened using the MIPOPEN command H330 Module AT Command User Manual Page 260 of 304 Bs FIBOCOM 14 10 MIPRUDP Receive Data from UDP Protocol Stack This unsolicited event is sent by the H330 to the terminal when data is received from the UDP protocol stack Set Command Event MIPRUDP lt Source_IP gt lt Source_Port gt lt socket_ID gt lt Left or SDL gt lt
290. t data gt In PDU mode CMGF 0 CBM lt length gt lt CR gt lt LF gt lt pdu gt The following table shows the CBM parameters lt Parameter gt Description lt sn gt Message serial number lt mid gt Message ID lt page gt Current page number lt pages gt Total number of pages lt data gt Message contents in text mode lt length gt Size of message in PDU mode format in octets lt pdu gt Message header and contents in PDU mode format See description in CMGR Read Message H330 Module AT Command User Manual Page 122 of 304 Bs FIBOCOM 7 1 12 CDSI Unsolicited Response New SMS STATUS REPORT Indication The CDSI unsolicited response is sent to the TE upon receipt of a new SMS STATUS REPORT SMS if the CNMI parameter lt ds gt is set to 2 This unsolicited message indicates that a new SMS STATUS REPORT message was received and is stored in location lt index gt Unsolicited Response CDSI lt mem gt lt index gt The following table shows the CDSI parameters lt Parameter gt Description lt mem gt Message memory space SM SIM memory storage lt index gt Location of the new message Example AT CMGF 1 OK AT CSMP 49 165 Set Message type to Status Report see CMGW OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 0 0 2 OK AT CMGS 052468000 gt Hello CMGS 188 OK CDSI SM 14 7 1 13 CD
291. t to the terminal only during a voice call waiting event A CCWA indication is not sent for a data call during in a voice session supported lt n gt s OK Command Syntax Response Remarks Set CCWA I lt n gt lt OK mode gt lt class gt if emodes 2andth The Set command enables disables the Call Waiting indication in the H330 command succeeds and in the network Activation CCWA deactivation and status query are lt status gt lt class gt lt CR Supported gt lt LF gt Note When the lt mode gt parameter is CCWA set to 2 network query the lt n gt lt status gt lt class gt parameter is ignored This means that no enable disable action is performed Ll while querying the network OK Read CCWA CCWA lt n gt The Read command returns the OK enable disable status of the call waiting indication in the H330 lt n gt Test CCWA CCWA list of The Test command returns lt n gt values supported by the H330 as a compound value The following table shows the lt class gt parameters lt Class gt Description 1 Voice telephony 2 data refers to all bearer services with lt mode gt 2 this may refer only to some bearer service if TA does not support values 16 32 64 and 128 4 Fax facsimile services 8 short message service 16 data circuit sync 32 data circuit async 64 dedicated packet access 128 dedicated PAD access 5 3 10 C
292. t value is 12 lt ParamName gt IPRFMT The format of reiceived data See description of lt value gt below lt value gt 0 Reiceived data with MIPRTCP and the data is incode 1 Reiceived data only and the data is without incode In received character string 2 Reiceived data format is lt CR gt lt LF gt MIPRTCP sid len data and the data is without incode 3 Reiceived data format is lt CR gt lt LF gt MIPRTCP sid len lt CR gt data and the data is without incode The default value is 0 lt value1 gt 0 ending with lt CR gt lt LF gt 1 ending without lt CR gt lt LF gt The default value is 0 H330 Module AT Command User Manual Page 257 of 304 Bs FIBOCOM Example Opening socket 2 already AT GTSET IPRFMT 0 0 OK AT MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK lt CR gt lt LF gt MIPRTCP 2 0 303 13233343536373839 lt CR gt lt LF gt AT GTSET IPRFMT 1 0 OK AT MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK Same as basic mode 0123456789 lt CR gt lt LF gt Only data without any information AT GTSET IPRFMT 2 0 OK AT MIPSEND 2 10 gt 0123456789abc OK MIPPUSH 2 0 MIPSEND 2 0 2048 OK lt CR gt lt LF gt MIPRTCP 2 10 0123456789 lt CR gt lt LF gt H330 Module AT Command User Manual Page 258 of 304 Bs FIBOCOM 14 8 MIPPUSH Push Data into Protocol Stack This
293. tatus report parameters in CMGW OK AT CSMP CSMP 49 167 0 0 OK AT CNMI 1 1 OK AT CNMI CNMI 1 0 0 1 0 OK AT CNMI 1 0 0 1 0 OK AT CMGS 0524680592 gt HELLO CMGS 168 OK CDS 6 168 972524680592 145 05 08 02 15 20 12 08 05 08 02 15 20 14 08 0 H330 Module AT Command User Manual Page 117 of 304 Bs FIBOCOM AT CNMI 1 0 0 2 OK AT CMSS 296 CMSS 185 OK CDSI SM 6 7 1 8 CNMA New Message Acknowledgment This command acknowlegde the receipt of a CMT and CDS response from the terminal to the H330 A CMT response receipt confirms the correct reception of a new SMS DELIVER message which was routed directly to the terminal A CDS response receipt confirms the correct reception of a new SMS STATUS REPORT message which was routed directly to the terminal When the H330 sends a CDS response to the terminal it waits a predefined timeout of 15 seconds for the CNMA acknowledgment The H330 will not send another CDS result code to the terminal before the previous one is acknowledged or the timeout expires When the H330 sends a CMT response to the terminal it waits a predefined timeout of 15 seconds for the CNMA acknowledgment The H330 will not send another CMT result code to the terminal before the previous one is acknowledged or the timeout expires Upon receipt of the CNMA command the H330 sends RP ACK to the network The acknowledged SMS will not be saved in message storage If the
294. ted already can upload data H330 Module AT Command User Manual Page 287 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Read FTPSTOR ERROR Not supported Test FTPSTOR FTPSTOR lt file Return command format name gt 0 1 L 0 0 XFFFFFFFE OK The following table shows the FTPSTOR parameters lt Parameter gt Description File name A file name or a file path name string the max length is 255 octets File type File type ASCII or Binary numeric in the range of 0 1 0 ASCII 1 Binary Offset Strat upload offset address range 0 OxFFFFFFFE Example AT FTPSTOR 123 TXT OK FTPSTOR 2 FTPSTOR 1 AT FTPSTOR 123 TXT 0 10 OK FTPSTOR 2 FTPSTOR 1 15 17 store data to filel123 TXT start to resume from the No 10 characters of offset address FTPRETR Retrieve a File This command makes the server send a copy file in the path name to the client It won t affect the file status and contents on the server site Hexadecimal data 03 and 10 will be translated add 10 in the front like server hexadecimal data 03 10 11 10 will be translated to 10 03 11 10 10 Command Syntax Response Action Remarks Set FTPRETR lt fil OK FTPRETR lt file_name gt is a complete qualified path and e_name gt l lt result gt or ERROR file name on the server site lt Offset gt is the lt file_type gt lt error_
295. ted by MCI command Defined values 0 Do not report lt TA gt value 1 Report lt TA gt value The default value is 0 MCI Indication After AT MCI command the neighbor cell information will return back by this MCI indication format few senconds later MCI lt serving cell ARFCN gt lt serving cell BSIC gt lt signal strength gt lt TA gt L lt neighbor 1ARFCN gt lt neighbor 1 BSIC gt lt signal strength gt lt neighbor 2 ARFCN gt lt neighbor 2 BSIC gt lt signal strength gt lt neighbor 3 ARFCN gt lt neighbor 3 BSIC gt lt signal H330 Module AT Command User Manual Page 171 of 304 Bs FIBOCOM strength gt lt neighbor 4 ARFCN gt lt neighbor 4 BSIC gt lt signal strength gt lt neighbor 5 ARFCN gt lt neighbor 5 BSIC gt lt signal strength gt lt neighbor 6 ARFCN gt lt neighbor 6 BSIC gt lt signal strength gt The following table shows the MCI parameters lt Parameter gt Description lt ARFCN gt Absolute Radio Frequency Channel Number Range 1 124 128 251 512 885 975 1023 lt BSIC gt Base transceiver Station Identity Code Range 0 63 lt signal Range 110 48 dBm strength gt For serving cell signal strength is defined as e In dedicated mode TCH Rx level e In idle mode average BCCH Rx level For adjacent cells signal strength is defined as the average Rx level in the both modes lt TA gt TA Timing A
296. ter a dialed number with comma digit e ATDL Voice dials the exact number that was last dialed including the DTMF tones sent e IfATDLis sent before any Dial command was issued mainly after Power On when the last number is an empty field the H330 will return NO CARRIER as mentioned in the ITU V 25 ter standard e CCFC 21 CCWA 43 CLIP 30 CLIR 31 COLP 76 will be treat as call number and dail it again H330 Module AT Command User Manual Page 47 of 304 Bs FIBOCOM Example atdl ATDL 035658278 OK OK NOICE call 5 3 4 H Hang up Call This command hangs up a call The H330 terminates the call whether it is a data or voice call and whether it is an incoming originating waiting or connected call ANO CARRIER message is returned to the terminal after the regular OK approval Note e To terminate hang up a MO data call while call is placed Any character sent from the terminal to the H330 causes the Data call termination and NO CARRIER is sent from the H330 to the terminal e To terminate a held Voice call or to terminate a call out of a MTPY call refer to CHLD Call Related Supplementary Services Command The following table shows the call states of the H command Call State Response Action IDLE Error operation not allowed Single Active Call released MTPY Active Call released all calls Incoming call RING Call released Single
297. ter gt Description lt indexn gt Order number of network operator in the SIM preferred operator list lt format gt Defines the lt oper gt format 0 Long alphanumeric format up to 16 characters default 1 Short alphanumeric format up to 8 characters 2 Numeric Name of the network operator string type lt format gt indicates if the format is alphanumeric or numeric lt oper gt see COPS GSM access technology 0 access technology not selected lt GSM_AcTn gt 1 access technology selected GSM compact access technology lt GSM_Compact_AcTn 0 access technology not selected gt 1 access technology selected UTRA access technology 0 access technology not selected lt UTRA_AcTn gt 1 access technology selected Note e If lt index gt is given but lt oper gt is left out entry is deleted e If lt oper gt is given but lt index gt is left out lt oper gt is put in the next free location e If only lt format gt is given the format of the lt oper gt in the read command is changed Note2 e User is prevented from editing index No 0 This index is reserved for the HPLMN record and can not be modified e When entering a new item with an lt index gt to a full list the H330 deletes the last item stores the new item in the requested entry and shifts the rest of the list down e When entering a new item without an lt index gt to a full list the H330 replaces the l
298. th P1 P2 Ox6A 0x88 Check Error referenced data not found Ox6B OxXX incorrect parameter P1 or P2 Ox6C OxXX Check Error wrong length xx is the correct length 0x6D OxXX unknown instruction code given in the command Ox6E OxXX wrong instruction class given in the command Ox6F OxXX technical problem with no diagnostic given lt response gt Response of a successful completion of the command previously issued hexadecimal character uppercase format STATUS and GET RESPONSE return data which gives information about the current elementary data file_id This information includes the type of file and its size refer to GSM 11 11 After READ BINARY or READ RECORD command the requested data will be returned lt response gt is not returned after a successful UPDATE BINARY or UPDATE RECORD command H330 Module AT Command User Manual Page 37 of 304 Bs FIBOCOM Example AT CRSM 176 28478 0 0 20 CRSM 145 165 FF AT CRSM 192 12258 CRSM 144 0 62168202412183022FE28A01058B032F06038002000A8800 OK AT CRSM CRSM 176 178 192 214 220 242 12037 28599 0 255 0 255 0 255 OK 4 1 14 GTUSIM Checks for USIM Card This command is used to check whether the current SIM is a 2G or 3G sim Command Syntax Response Action Remarks Set AT GTUSIM GTUSIM lt state gt State 0 2G SIM OK State 1 3GSIM Read AT GTUSIM GTUSIM lt state gt State 0 2GSIM OK State 1 3GSIM 4 1 15 CC
299. th gt character set as specified by command Select TE Character Set CSCS lt adnumbe gt string type phone number of format lt adtype gt lt adtype gt type of address octet in integer format refer TS 24 008 subclause 10 5 4 7 lt secondtext gt string type field of maximum length lt slength gt character set as specified by command Select TE Character Set CSCS lt email gt string type field of maximum length lt elength gt character set as specified by command Select TE Character Set CSCS lt glength gt integer type value indicating the maximum length of field lt number gt lt alength gt integer type value indicating the maximum length of field lt adnumber gt lt slength gt integer type value indicating the maximum length of field lt secondtext gt lt elength gt integer type value indicating the maximum length of field lt email gt H330 Module AT Command User Manual Page 98 of 304 Bs FIBOCOM Example AT CPBS SM Selecting phone book OK AT CPBF Lin CPBF 1 18888888 129 Linzhao OK AT CPBF Voice Searching for string Voice and finding Voice Mail CPBF 2 8613800138000 145 Voicemail OK AT CPBF Searching for everything in phone book and finding all entries CPBF 1 18888888 129 Linzhao CPBF 2 8613800138000 145 Voicemail CPBF 3 18888888 129 abc OK 6 1 4 CPBW Write Phone Book Entry This command enables the user to store a new entry in the phone book or ed
300. the SIM information and can be 0x90 0x00 normal entry of the command Ox9F OxXX length XX of the response data 0x92 0x0X update successful but after using an internal retry routine X times 0x92 0x40 memory problem H330 Module AT Command User Manual Page 35 of 304 Bs FIBOCOM 0x94 0x00 no EF selected 0x94 0x02 out of range invalid address 0x94 0x04 file ID not found pattern not found 0x94 0x08 file is inconsistent with the command 0x98 0x02 no CHV initialized 0x98 0x04 access cond Not fullfiled unsucc CHV verify authent failed 0x98 0x08 in contradiction with CHV status 0x98 0x10 in contradiction with invalidation status 0x98 0x40 unsucc CHV verif Or UNBLOCK CHF CHV blocked UNBL blocked 0x98 0x50 increases can not be performed Max value reached 0x61 OxXX SW2 indicates the number of response bytes still available Use GET RESPONSE to access this data 0x62 OxXX Warning state unchanged 0x62 0x00 Warning no information provided 0x62 0x81 Warning part of returned data may be corrupt 0x62 0x82 Warning end of file record reached bad cmd 0x62 0x83 Warning selected file invalidated 0x62 0x84 Warning bad file control information format 0x63 0xXX Warning state unchanged 0x63 0x00 Warning no information provided 0x63 0x81 Warning file filled up with last write 0x63 OxCx Warning counter value is x 0x64 OxXX Error state unchanged 0x65 OxXX Error state changed 0x65 0x00 Error
301. ting buffer will be push into the protocol stack either the buffer is full or the data length reach the watermark Arriving data to accumulating buffer triggers a start of time defined in timeout countdown When counter reaches zero data is moved into the protocol stack If new data arrived before time is reached zero it is re initialized If data in accumulating buffer reached watermark it is pushed to the accumulating buffer as usual but if after automatic push there is some remaining data time countdown is started Note If there is data in the accumulating buffer the MIPSETS command will be rejected H330 Module AT Command User Manual Page 251 of 304 Bs FIBOCOM The following table shows t Command Syntax Response Action Remarks Set MIPSETS lt Sock OK Timeout is et_ID gt lt Size gt lt Ti Se defined in meout gt milliseconds ERROR MIPSETS lt err gt Read MIPSETS MIPSETS lt Socket_ID gt lt Current Size Settings gt lt Timeout gt OK For all ACTIVE sockets Test MIPSETS MIPSETS 1 4 list of supported lt size gt s list of supported lt Timeout gt s OK he MIPSETS parameters lt Parameter gt Description Size Size of the buffer 1 lt size lt 2048 The default value is 2048 Timeout O 1000 0 means no timeout is used default Extended err 3 Operation not allowed Example AT MIPSETS 1 340 Asks the H330 to accumulate 340 bytes
302. tiparty without accepting incoming call 8 release all calls Example AT CHLD CHLD 0 1 1x 2 2x 3 4 6 7 8 OK AT CCWA 1 OK atd9311234567 OK Enable call waiting Originate a voice call OK conversation CCWA 358317654321 145 1 Bob Awaiting call alerts AT CHLD 2 Put first call on hold and answer the second call OK conversation AT CHLD 3 OK Add the held call to the conversation MTPY conversation H330 Module AT Command User Manual Page 60 of 304 Bs FIBOCOM AT CHLD 22 Split Place the MO active call on hold MT call remains active OK AT CHLD 0 Release the held call OK NO CARRIER ath Release the active call OK NO CARRIER atd9311234567 Originate a voice call OK OK CCWA 055728386 129 1 0 Waiting call alerts AT CHLD 1 Release the active call accept the waiting call OK NO CARRIER Active 9311234567 was released OK Waiting 055728386 was answered 5 3 12 CCFC Call Forwarding Number and Conditions This command enables control of the call forwarding supplementary service Registration erasure activation deactivation and status query are supported Command Syntax Response Action Remarks Set CCFC lt reason gt If the command succeeds lt mode gt lt numbe CCFC The Set command r gt lt type gt lt class lt status gt lt class gt lt number gt lt type instruc
303. to be displayed upon connection of a voice call with a remote party The OK and CONNECT messages are available CME ERROR lt err gt Command Syntax Response Action Remarks Set MDC lt mo OK The Set command selects which of the de gt i supported messages will be displayed upon connection of a voice call lt mode gt Command Parameters 0 Display OK on voice call connection 1 Display CONNECT on voice call connection Default Values Power Up As previously saved in NVM 0 Before Set command is first used Read MDC MDC lt mode gt The Read command should return the current OK selection of lt mode gt Test MDC MDC list of The Test command returns the possible apparten lt mode gt values lt mode gt s OK Example AT MDC MDC 0 1 OK AT MDC 1 OK ATD lt number gt OK CONNECT H330 Module AT Command User Manual Page 70 of 304 Bs FIBOCOM AT MDC MDC 1 OK AT MDC 0 OK ATD lt number gt OK OK AT MDC MDC 0 OK 5 3 18 MHUP H330 Hung UP call This command hung up specific call or all calls and reported a specific disconnect cause to the NW Command Syntax Response Action Remarks Set AT MHUP lt cau OK se gt lt call_id gt or CME ERROR lt err gt Test AT MHUP MHUP Show list of supported lt cause gt s 1 16 17 18 27 31 0 7 and list of supported lt call_id gt s OK The following table sh
304. tone detection Disabled Busy detection Disabled 2 CONNECT lt text gt result code given upon entering online data state Dial tone detection Enabled Busy detection Disabled 3 CONNECT lt text gt result code given upon entering online data state Dial tone detection Disabled Busy detection Enabled 4 CONNECT lt text gt result code given upon entering online data state Dial tone detection Enabled Busy detection Enabled The default value is 4 4 1 5 S Bit Map Registers This command reads writes values of the S registers The H330 supports this command for various S values according to official specifications ITU I ETSI or manufacturer specific Command Syntax Response Action Remarks Set ATSn lt valu OK The Set command is allowed for e gt r read write S registers and not allowed for read only S registers CME ERROR lt err gt Read ATSn lt current value of S register n gt OK or CME ERROR lt err gt Test The Test command for Sn is not defined by ITU and therefore is not supported by the H330 The H330 returns an error The following table shows the different S registers and their associated values H330 Module AT Command User Manual Page 27 of 304 Bs FIBOCOM escape character during CSD connections Sn PE Min Max Default P Value Value Value SO Sets gets number of rings before auto answe
305. tors This command is used to edit the PLMN selector lists in the SIM card or active application in the UICC GSM or USIM If no list has been previously selected the EFPLMNwWAcT user controlled PLMN selector with Access Technology list is the one accessed by default H330 Module AT Command User Manual Page 160 of 304 Bs FIBOCOM Command Syntax Response Action Remarks Set AT CPOL OK or lt index gt aac CME ERROR lt err gt Note In case the index already f exists in the list the new entry will L lt oper gt L seas erase the old one and replace it in lt GSM_Ac f the list T gt lt GSM_ Compact_ The H330 may also update this list AcT gt lt UT automatically when new networks RAN_AcT gt are selected J Read AT CPOL CPOL lt index1 gt lt format gt lt op er1 gt L lt GSM_AcT1 gt lt GSM_C ompact_AcT1 gt lt UTRAN _AcT1 gt lt CR gt lt LF gt CP OL lt index2 gt lt format gt lt op er2 gt lt GSM_AcT2 gt lt GSM_C ompact_AcT2 gt lt UTRAN _AcT2 gt OK or CME ERROR lt err gt Test AT CPOL CPOL list of The Test command displays the supported lt index gt s list entire index range supported by of supported lt format gt s the SIM OK or CME ERROR lt err gt Index range is SIM dependent H330 Module AT Command User Manual Page 161 of 304 Bs FIBOCOM The following table shows the CPOL parameters lt Parame
306. try The used character set should be the one selected with Select Terminal Character Set CSCS lt alpha gt is case sensitive and should be placed in quotes alpha lt n gt This parameter is also called speed dial location It is an integer type memory location lt n gt should be in the range of locations available in the memory used lt mem gt This parameter is not case sensitive Example AT CPBS SM OK AT CSCS IRA H330 Module AT Command User Manual Page 46 of 304 Bs FIBOCOM OK AT CPBW 1 035659090 129 VoiceMail OK AT CPBR 1 CPBR 001 035659090 129 VoiceMail OK atd gt VoiceMail Phonebook by name OK OK ath OK NO CARRIER 5 3 3 DL Dial Last Number The DL command places a voice call to the last number dialed The call progress information success failure is reported in the same way as for the Dial command Command Detailed Description ATDL Initial Response Last Number retrieved ATDL lt DIAL DIGITS gt 1st response Voice call placement begins OK 2nd response Voice call connected OK The following table shows the DL parameters lt Parameter gt Description semicolon If the semicolon is given a voice call is originated to the last dialed number If the semicolon is not given a Data call is originated Note The last dialed call type is irrelevant to the DL command Note When ATDL is issued af
307. ts the H330 which gt L lt subaddr gt lt sa gt lt subaddr gt lt satype gt lt time gt call forwarding settings to type gt lt time gt lt CR gt lt LF gt request from network CCFC The Set command in lt status gt lt class gt lt number gt lt type query mode interrogates gt lt subaddr gt lt satype gt l lt time gt IL the network about the J subscriber current call i forwarding status CCFC list of supported lt reason gt s Test CCFC CCFC lt reason gt The Test command OK returns lt reason gt values supported by the H330 to the terminal H330 Module AT Command User Manual Page 61 of 304 Bs FIBOCOM The following table shows the CCFC parameters lt Parameter gt Description lt reason gt 0 Unconditional 1 Mobile busy 2 No reply 3 Not reachable 4 All call forwarding 5 All conditional call forwarding lt mode gt 0 Disable 1 Enable 2 Query status 3 Registration 4 Erasure lt number gt Calling line number The number format is specified by lt type gt lt type gt Type of address octet in integer format 145 Default when dialing string includes international access code character 129 Default when making a local call lt subaddr gt NULL field not used String type subaddress of format specified by lt satype gt lt satype gt Field not used Value is always 128 unknown type of
308. ul FTPCDUP 1 AT FTPPWD FTPINFO PWD OK FTPINFO 257 export home test is current directory FTPPWD 2 export home test is current directory FTPPWD 1 15 10 FTPDEL Delete the File This command is used for delete the file on server sites Command Syntax Response Action Remarks Set FTPDEL lt file_n OK FTPDEL lt result gt lt file_name gt is a complete qualified ame gt or ERROR lt error_code gt path and file name on server sites The command execution result return to the user as an unsolicited response 0 operation fails 1 operation success Read FTPDEL ERROR Not supported Test FTPDEL FTPDEL lt file Return command format name gt OK The following table shows the FTPDEL parameter lt Parameter gt Description File name The file name need to be deleted string the max length is 255 octets H330 Module AT Command User Manual Page 282 of 304 Bs FIBOCOM Example AT FTPDEL 1234 txt FTPINFO DELE 1234 txt OK FTPINFO 250 Delete operation successful FTPDEL 1 15 11 FTPREN Rename File This command is used for rename the file or folder of current directory Command Syntax Response Action Remarks Set FTPREN lt file_n FTPREN lt result gt or lt file_name_from gt indicates the file ame_from gt ERROR lt error_code gt need to be named lt file_name_to gt lt fil
309. unread messages with changing message stat CMGL 1 REC UNREAD 972544565034 05 01 01 09 21 22 08 message text OK AT CMGL OK the message stat was changed No rec unread messages AT CPMS ME CPMS 11 61 11 61 2 20 OK AT CMGL sto sent CMGL 142 STO SENT 054565034 message text OK AT CSDH 1 OK AT CMGL STO SENT CMGL 142 STO SENT 054565034 81 lt message length gt H330 Module AT Command User Manual Page 128 of 304 Bs FIBOCOM message text OK AT CMGS 18 send to myself gt 079179521201009511000c917952446505430004AA0441424344 CMGS 68 OK AT CPMS sm CPMS 2 20 11 61 2 20 OK change to SIM to read the incoming messages 7 1 15 CMGR Read Message These commands handle the reading of SMS The command displays the message in location lt index gt of the preferred message storage lt mem1 gt selected using the CPMS command If the status of the message is RECEIVED UNREAD the CMGR command changes the status to RECEIVED READ successful and SMS SUBMIT CMGR lt stat gt lt da gt lt alpha gt lt toda gt lt fo gt lt pid gt lt dcs gt L lt vp gt lt sca gt lt tosca gt lt length gt lt CR gt lt LF gt lt da ta gt If text mode CMGF 1 command execution is successful and SMS COMMAND CMGR lt stat gt lt fo gt lt ct gt lt pid gt lt mn gt lt da gt lt toda gt lt length gt lt CR gt lt LF gt lt c
310. up to 16 characters long The short alphanumeric format can be up to 8 characters long The numeric format is the GSM Location Area Identification number refer to GSM 04 08 subclause 10 5 1 3 consisting of a three BCD digit country code as per ITU T E 212 Annex A plus a two BCD digit network code which is administration specific The returned lt oper gt is not in BCD format but in IRA characters converted from BCD and therefore the number has the following structure country code digit 3 country code digit 2 country code digit 1 network code digit2 network code digit 1 lt AcT gt Indicates the radio access technology and values can be 0 GSM 2 UMTS H330 Module AT Command User Manual Page 159 of 304 Bs FIBOCOM lt Parameter gt Description lt plmn_list gt Indicates whether the PLMN is present on the EHPLMN list the User Controlled PLMN List or the Operator Controlled PLMN List 0 PLMN is present on the EHPLMN list 1 PLMN is present on the User Controlled PLMN List 2 PLMN is present on the Operator Controlled PLMN List Example AT COPS COPS 2 CHN UNICOM UNICOM 46001 2 2 CHN UNICOM UNICOM 46001 0 3 CHINA MOBILE CMCC 46000 0 OK AT COPS COPS 1 0 CHN UNICO OK AT COPS 2 OK AT CREG 2 OK CREG 3 AT COPS 4 2 46001 CREG 3 CREG 2 CREG 1 27A0 0DEB OK AT COPS COPS 1 2 46001 2 OK M 2 9 1 6 CPOL Preferred Opera
311. us of the SIM is still enabled but the PIN is READY for this session The SIM is enabled per session After power up SIM must be unlocked again by using the CLCK command The following case shows an example of three unsuccessful attempts at entering the PIN AT CPIN CPIN SIM PIN OK AT CPIN lt wrong pin gt CME ERROR incorrect password AT CPIN lt wrong pin gt CME ERROR incorrect password H330 Module AT Command User Manual Page 145 of 304 Bs FIBOCOM AT CPIN lt wrong pin gt CME ERROR SIM PUK required AT CPIN CPIN SIM PUK PIN is blocked The PUK is needed for unblocking OK AT CPIN lt PUK gt lt NEW PIN gt Enter PUK and new PIN OK AT CLCK FD 1 lt wrong PIN2 gt CME ERROR incorrect password AT CLCK FD 1 lt wrong PIN2 gt CME ERROR incorrect password AT CLCK FD 1 lt wrong PIN2 gt CME ERROR SIM PUK2 required AT CPIN CPIN SIM PUK2 PIN2 is blocked The PUK2 is needed for unlocking OK AT CPIN lt PUK2 gt lt NEW PIN2 gt Enter PUK2 and new PIN2 OK 8 1 4 TPIN Query Number of Remaining SIM PIN PUK Entering Attempts This command returns the number of remaining attempts of entering the PIN and PUK for the SIM card in use The command returns the number of remaining attempts for PIN1 CHV1 PIN2 CHV2 PUK1 unblock CHV1 and PUK2 unblock CHV2 Number of available attempts is provider dependant Typically it is 3 attempts for PIN 10 attempts f
312. used ME TA converts each 8 bit octet into two IRA character long hexadecimal number e g octet with integer value 42 is presented to TE as two characters 2A IRA 50 and 65 H330 Module AT Command User Manual Page 87 of 304 Bs FIBOCOM lt Parameter gt Description value are language ID already in it 72 USC2 16 bit 68 8 bit Each other value except of 96 80 and 240 are 7 bit Not supported values are 96 80 240 The default value is 15 7 bit lt dcs gt GSM 03 38 Cell Broadcast Data Coding Scheme in integer format The supported 17 USC2 Language Indicator The first character in a USC2 Lang IND has the language ID in it This situation is not defined by the GSM 7 07 or the 3GPP 27 007 so the assuming that the first character should have the correctly formatted and packed information needed after mobile Initiated operation information needed after mobile initiated operation index as described in CUSD Termination Cause Table Index 3 Other local client has responded 4 Operation not supported 5 Network time out lt m gt 0 No further user action required network initiated US SD Notify or no further 1 Further user action required network initiated USSD Request or further 2 USSD terminated by network the reason for the termination is indicated by the CUSD Termination Cause Table Index Termination Cause Index NO_CAUSE 0 C
313. ushing the codes 2 circuit switched preferred use Packet Domain if circuit switched not available Example AT CGEREP 1 0 OK AT CGEREP 2 2 ERROR AT CGEREP CGEREP 0 2 0 1 OK AT CGEREP 2 0 AT CGEREP CGEREP 2 0 OK 13 2 18 H330 Module AT Command User Manual CGTFT Traffic Flow Template This command allows the TE to specify a Packet Filter PF for a Traffic Flow Template TFT that is used in the GGSN for routing of down link packets onto different QoS flows towards the TE Page 241 of 304 Bs FIBOCOM filter identifier gt lt evaluation precedence index gt lt source address and subnet mask gt lt protocol number ipv4 next header ipv6 gt lt destination port range gt lt source port range gt lt ipsec security parameter index spi gt lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt lt CR gt lt LF gt CGTFT lt cid gt lt packet filter identifier gt lt evaluation precedence index gt lt source address and subnet mask gt lt protocol number ipv4 next header ipv6 gt lt destination port range gt lt source port range gt lt ipsec security parameter index spi gt lt type of service tos ipv4 and mask traffic class ipv6 and mask gt lt flow label ipv6 gt Command Syntax Response Action Remarks Set CGTFT lt cid gt lt packet filt
314. ween the TE and the network using one or more GPRS PDP types This may include performing a GPRS attach and one or more PDP context activations If the parameters are accepted MT displays the intermediate result code CONNECT on TE and enters the online data state thereafter data transfer may proceed No other commands following CGDATA in the command line will be processed Command Syntax Response Action Remarks Set CGDATA CONNECT lt L2P gt lt cid gt L lt cid gt L J It follows data transfer or CME ERROR lt error gt Set command specifies the lt L2P gt and lt cid gt to establish data call csd connection state Test CGDATA CGDATA list of supported lt L2P gt s OK Test command returns values supported as a compound value H330 Module AT Command User Manual Page 237 of 304 Bs FIBOCOM The following table shows the CGDATA parameters lt Parameter gt Description lt L2P gt a string parameter that indicates the layer 2 protocol to be used between the TE and MT NULL none for PDP type OSP IHOSS Obsolete PPP Point to point protocol for a PDP such as IP PAD character stream for X 25 character triple X PAD mode Obsolete X25 X 25 L2 LAPB for X 25 packet mode Obsolete M OPT PPP MS supports manufacturing specific protocol M HEX MS supports manufacturing specific protocol M RAW_IP MS supports manufacturing specific protocol lt cid g
315. wer cycle Command Syntax Response Action Remarks Set CRSL lt level gt OK The Set command sets the call ot ringer and alert SMS level CME ERROR lt err gt Read CRSL CRSL lt level gt The Read command displays the OK current ringer alert SMS sound level setting Test CRSL CRSL list of The Test command displays the list supported lt level gt s of supported sound level settings OK The following table shows the CRSL parameters lt Parameter gt Description lt level gt 0 7 Manufacturer specific volume range 0 is lowest volume not mute The default value is 4 11 2 2 CLVL Loudspeaker Volume This command sets the volume of the internal loudspeaker of the H330 H330 Module AT Command User Manual Page 193 of 304 Bs FIBOCOM Note In this command the new value remains after power cycle The CLVL command can be used even when the SIM is not inserted supported lt level gt s OK Command Syntax Response Action Remarks Set CLVL lt level gt OK The Set command sets the internal oF loudspeaker volume level CME ERROR lt err gt Read CLVL CLVL lt level gt The Read command displays the OK current internal loudspeaker volume setting Test CLVL CLVL list of The Test command displays the possible loudspeaker volume settings The following table shows the CLVL parameters lt Parameter gt
316. with phone capabilities in order to prevent interference from a nearby environment This enables other functionality to be used continuosly in environments where phone use is either impractical or not permitted For example on airplanes the use of cellular phones is forbidden during the entire flight but the use of computers is allowed during much of the flight This command enables other functionality to continue while preventing use of phone functionality Command Syntax Response Action Remarks Set CFUN lt fun gt OK The Set command selects the level of CME ERROR lt err gt functionality lt fun gt in the smart phone or PDA incorporating H330 Read CFUN CFUN lt fun gt The Read command displays the lt STK_mode gt current level of functionality OK Test CFUN CFUN list of The Test command displays the list of supported lt fun gt s supported functionality settings OK H330 Module AT Command User Manual Page 182 of 304 Bs FIBOCOM The following table shows the AT CFUN parameters lt Parameter gt Description lt fun gt Functionality levels 0 Turn off With logging out network 1 Full functionality meaning start up MS from offline mode 4 Disables phone transmit amp receive RF circuits Flight mode 6 Enables the SIM toolkit interface and fetching of proactive commands by SIM APPL from the SIM card 7 Disables the SIM toolkit interface and fetching
317. wnload 123 txt OK FTPGET 2 at ftprecv 30 read 30 bytes FTPRECV 30 e U8 nvm_dynamic adr_nvm_d OK FTPGET 1 GET file downloading completed at ftpget 123 txt 0 283800 start to download from offset address 283800 OK at ftprecv 3000 read 3000 bytes data FTPRECV 8 it already downloaded when read 8 bytes file agps_nv FTPGET 1 GET file downloading completed OK H330 Module AT Command User Manual Page 292 of 304 Bs FIBOCOM 16 PCM Command 16 1 MADIGITAL Enable Digital Audio or Disable Digital Audio This command is used for enable digital audio or disable digital audio CS42L73 CODEC chip is installed in the module if the clients do not want to use the internal CODEC this command can output the digital signals directly Command Syntax Response Action Remarks Set MADIGITAL lt X gt gx Be Configure use interal CODEC or not use interal ERROR CODEC output the digital signal directly X set to be 0 use internal CODEC X equals to 1 output the digital signal directly Read MADIGITAL MADIGITAL X Return to the original settings return 0 if no OK configuration Test MADIGITAL MADIGITAL 0 1 Return OK if empty OK The following table shows the MADIGITAL parameters lt Parameter gt Description lt X gt x 0 use internal CODEC 1 output digital audio directly Example AT MAIDIGITAL 0 use inside CODEC OK H