M130 - Meriam Process Technologies

image

Contents

1. cccccecssececseececeeseeceeceececseeeeceeseeesssnaeeess 8 T C Simulation Manual ccccccccssecssseeessecsseeeeseecseeeeseeenes 9 T C Simulation Auto ccccecsccceesceeseceeececseeeeeeeeseeeeeeeeeseeenes 9 MEAS SETUP eiiieaen aae oa EE EEE 10 SIM MANUAL SETUP ccsccccccccssecsseeecseseseeesseeesseees 11 SIM AUTO SETUP cscisccssscdivevcsscetesssciincecd cocsnstesseesccatessceuis 12 Engineering Units Select 0c eeeeeeseceseceeeeneeeneeeeeeeee 14 Record Mode sirrenissonepina eninin a ra RERE a 14 OFF TIMET wiv iicccicnantdteteidiaiicienedind E a EREE 15 Zeroing the M130 canonar ennnen ie 15 Specifications sciens atirini ae uein iR aois 16 T C Measurement amp Simulation Accuracy Table 17 Certificato eneo iine oeann EEEN EPan Hn EENET SEKE EEE 18 Changing the Batteries eee ee ceeeesceseeeeceeeeseeceeeaeeees 18 User Connections eiicadscseciessatseescsvarsensbccsctave cueveeievecesbeseduerss 20 Contact Information ccccccccssccsscesscesseeeeeecsseeeeseecsseeeenees 21 www meriam com AA meriam Page 2 of 21 z M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Introduction Thank you for purchasing this Meriam product Meriam has been providing innovative reliable cost effective measurement and calibration solutions since 1911 The M130 Thermocouple calibrator has been designed using the latest technology to provide reliable accuracy throughout
2. section VIEW view previously recorded values RECORD select ENTER to access submenus MANUAL press ENTER button to record values AUTO values automatically recorded every 5 seconds Note Main and submenus are continuous scrolling menus Use lt or P to scroll through the menus www meriam com NA menam process technologies Page 10 of 21 ANRT M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 SIM MANUAL SETUP Simulation Mode s Manual menu structure VALUE ADJUST UNITS C F R K TC TYPE B lt HuwmznAcmo 0 100 START UNITS TC TYPE URV LRV STEP 25 START UNITS TC URV LRV Press ENTER amp use increment or decrement group keys to set a numeric value press ENTER to start Select desired unit of simulation engineering units are C engineering units are F engineering units are R engineering units are K Select T C type or mV engineering units are mV engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only Outputs 0 and 100 of setup Starts 0 of range ENTER toggles to 100 0 Edit units corresponding to 0 100 same as above Select T C type same as above Upper Range Value for T C and u
3. Auto simulate step or ramp output functions in temperature units or mV SIM icon shown at top of display Each Functional Mode has three possible States 1 Run active measurement or simulation MEAS or SIM icon shown at top of display 2 Setup access navigation menus MEAS amp SETUP or SIM amp SETUP icons shown at top of display 3 Edit Setup edit a parameter within a navigation menu EDIT MEAS amp SETUP or EDIT SIM amp SETUP icons shown at top of display The M130 will power up in its previous functional mode when turned ON Example if previous use was SIM Auto then next power up will default to SIM Auto Simulation will restart when user confirms the desired setup and presses the ENTER key two times See the table below for functional modes states and key functions www meriam com aw meriam process technologies Page 7 of 21 ARR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 FUNCTIONAL MODES STATES AND KEY FUNCTIONS Run Setup Edit Setup MEAS MEAS SETUP EDIT MEAS Keys or or SETUP or SIM SIM SETUP EDIT SIM SETUP SETUP Enters Setup state Back one menu Discards changes and or ends simulation level or exits exits Edit Setup state activity Setup state FUNC gt Next Functional Next menu item mode lt UNITS Next engineering Previous menu unit item ENTER Toggles lower Selects menu Saves changes and display line item
4. accepts the currently displayed item value during setup activities During active simulation activity the ENTER key toggles between T C type with temperature unit information and of range INCREMENT Group Keys gt The three keys beneath this symbol allow the user to scroll through edit selections when EDIT icon is lit The keys are also used to increment numeric values For this function the narrow band signifies fine adjustment the medium band signifies medium adjustment and the wide band signifies coarse www meriam com aA meram process technologies Page 5 of 21 Jeane corey M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 adjustment for changing the values The positive sign indicates the Group Keys will increment the displayed value DECREMENT Group Keys QP n The three keys beneath this symbol allow the user to scroll through edit selections when EDIT icon is lit The keys are also used to decrement numeric simulation values For this function the narrow band signifies fine adjustment the medium band signifies medium adjustment and the wide band signifies coarse adjustment for changing the values The negative sign indicates the Group Keys will decrement the displayed value In addition when the narrow band and wide band areas are pressed simultaneously HOME the unit will return to the Measure mode default position Liquid Crystal Display LCD BAT EDIT MEAS S
5. and 240 measurements The measurement data is preserved in non volatile memory until another REC session is started RECORD Data To start a manual record session from Measure Mode press SETUP key and then lt or P key until RECORD is displayed Press ENTER and then lt or gt key until MANUAL is displayed Press ENTER Previously stored information is deleted and M130 enters Record Manual Mode The REC icon flashes in upper right Press Enter to save a displayed value to memory Pressing SETUP key ends the session To start an automatic record session from Measure Mode press SETUP key and then lt or gt key until RECORD is displayed Press ENTER and then lt 4 or gt key until AUTO is displayed Press ENTER Previously stored information is deleted and M130 enters Record Auto Mode The REC icon flashes in upper right Values are stored every 5 seconds until the SETUP key is pressed to end the session or 240 values are saved REC is displayed on the lower display line each time a sample is stored After 240 measurements have been recorded or the SETUP key is pressed the REC www meriam com aw menam process technologies Page 14 of 21 ANR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 session will stop and the RECORD Data mode will automatically exit to Measure Mode VIEW Recorded Data To view the results of a REC session from Measure Mode press SETUP key and then lt or P key until VIEW i
6. for specified ranges The red backlight will illuminate and will be displayed e Ifa thermocouple has not been connected to the unit T C OPEN will be displayed T C Simulation Manual e When unit is turned on the display defaults to the previous mode with the last T C type and Units chosen To enter the Simulation Manual mode press the FUNC P key until SIM MANUAL appears then press the SETUP key T C Simulation Auto e When unit is turned on the display defaults to the previous mode with the last T C type and Units chosen To enter the Simulation Auto mode press the FUNC gt key until SIM AUTO appears then press the SETUP key www meriam com aw menam process technologies Page 9 of 21 ANRT M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 MEAS SETUP Measure Mode Setup menu structure T C TYPE select ENTER to access submenus mV engineering units are mV B engineering units are temperature only E engineering units are temperature only J engineering units are temperature only K engineering units are temperature only N engineering units are temperature only R engineering units are temperature only S engineering units are temperature only T engineering units are temperature only OFF TMR select ENTER to access submenus 30 MIN shuts off in 30 min without new key stroke OFF must use ON OFF key to shut off F RECAL select ENTER to access submenu ZERO set zero See Zeroing the M130
7. its entire operating temperature range dependable operation and exceptional battery life The compact design makes the unit easy to carry and the intuitive user interface makes it easy to use Temperature measurements simulations are displayed on a large easy to read liquid crystal display LCD This unit has two backlights a green backlight which is user activated to improve readability in low light conditions and an automatic red backlight which indicates an over range condition Twelve keys provide access to the functional modes and menus including Measure Simulate Setup Run Record Edit and Backlight activation A list of these functions is printed on the back of the case Wwww meriam com ae menam ess technologies Page 3 of 21 ANRT M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 User Interface Keypad Functions ON OFF Ke ON OFF key represented by the standard ON OFF symbol turns the M130 ON or OFF note the ON OFF key must be held until the display turns on or off Upon power on the M130 will perform a self test displaying the Meriam product ID and all segments for approximately 1 2 seconds then go into the mode in use when unit was powered off The firmware version is displayed at the end of the self test BACKLIGHT Key The BACKLIGHT key represented by the standard light bulb symbol turns the green display backlight on and off The backlight will remain on for a
8. prior to zeroing Note factory reference temperature is 23 C If the ZERO is unsuccessful the message ZERO FAILED will be displayed briefly In this case check to be sure the Shorting Plug is properly installed and repeat the ZERO process If ZERO FAILED appears again contact Meriam for technical support www meriam com aw menam process technologies Page 15 of 21 ARR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Specifications Type and Range T C types B E J K N R S T amp milli volts Milli volts range 15mV to 80 00 mV T C Measurement amp Simulation Accuracy See Table below mV Accuracy 0 005 of reading 6u V mV Temp Effect 2 uV C Factory Ref Temp 23 C Cold Junction Effect 0 05 C C Cold Junction Accuracy 0 1 C at 25 C T C Resolution T C types E J K N T 0 1 C T C types B R S 1 C mV 0 001 mV 1 uV Temperature Storage 40 C to 85 C 40 F to 185 F Operating 10 C to 50 C 14 F to 122 F Humidity 10 to 90 Rh Connection Measure standard mini T C connector Simulate standard mini T C connector Zero supplied mini T C connector with internal copper short Maximum Input Voltage 30VDC Battery Type 3 x AA battery field replaceable Battery Operation gt 100 hours continuous use without the backlight for measure or simulation modes 1 year shelf life low battery warning at approximately 2 hours remaining run t
9. 8 Contact Information If the M130 is damaged it should be returned to the factory for servicing Contact the Meriam Process Technologies representative in your area or call the factory at the numbers listed below for a Return Material Authorization RMA number Meriam Process Technologies 10920 Madison Ave Cleveland OH 44102 Ph 216 281 1100 FAX 216 281 0228 If certificate of NIST traceability is required please be sure to request this service at time of repair www meriam com aA menam Page 21 of 21 a Matt Feteer company
10. IM SETUP REC lt Mode icons H H H H o o ae A z E a E a we Menus units or m r het ta i i 3 nA m h he other es The LCD displays e current Functional Mode and or state via icons along top of display e primary measurements via the large middle segments e menu items and additional information via the bottom alpha numeric segments The LCD incorporates two backlights e a green backlight which is user activated via the BACKLIGHT key e a red backlight which is automatically activated during an over range under range condition www meriam com aw menam process technologies Page 6 of 21 ANR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 During an over range under range condition the red backlight will over ride the green backlight if it was already on Once the condition is corrected the green backlight will be restored to its previous state assuming the backlight auto off timer did not expire Notes 1 The backlight should be turned off when not needed to conserve battery power 2 The backlight will be automatically disabled when the M130 reaches battery mode Functional Modes and States The M130 supports measurement and simulation activities using the following Functional Modes 1 Measure temperature units or measure mV MEAS icon shown at top of display 2 Simulate Manual simulate fixed values of temperature units or mV SIM icon shown at top of display 3 Simulate
11. M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 M130 THERMOCOUPLE CALIBRATOR USER MANUAL T C Calibrator Meriam Process Technologies M130 is a handheld calibrator for thermocouple T C measurement or simulation Eight T C types are supported referencing NIST175 and ITS90 standards Temperature can be displayed in selectable engineering units of C F R K www meriam com a menam Page 1 of 21 amanan na M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Table of Contents Introduction 0 cccceccceceesececeesececseceeceseneeecneaeeecseeaeeesseseeeneaaes 3 User Interface cccccccecsscessscesecsssceeeecsseeseseecsseesesaeeneeeesaeenes 4 Keypad Functions 0 ceeceeeceesseceseeeeseeceeeeeeaeceeeeeenaeceeeeeenaeees 4 ON OFF Key cccceceeescesccesecesecececeeecaeeeaeeeseeeeeeeeeeereesreeeeenaees 4 BACKLIGHT Key ccccecccesessseeeeeeceeeeeeeeeeeeeeeneeneeneenseenees 4 SETUP KEY EE E ERS 4 FUNCTION Key cecccesecsceeseeeseeeeeescecseeeseeeeeeeeeeereeseeeeeenaees 5 UNIES Re Ycee e EEEN 5 ENTER Keyesa EE REE EEEE OEE EE 5 INCREMENT Group KEyS seseseeeseeerrsereresrerrerrerrsrrereere 5 DECREMENT Group Key sssseessseereseeerrsreerrerrrrerrrrrere 6 Liquid Crystal Display LCD ssesseseseeeereeeeeesesrsrseererrsrsrrreeress 6 Functional Modes and States ccsccccssseeceeseeeeeeeseeeesssneeees 7 T C Measurement
12. eral purpose use only Do not use in potentially hazardous atmospheres meriam www meriam com A process technologies Cleveland OH 44102 USA M1 Series Handheld Calibrator for General Locations TC Calibrator CAUTION Use 3 AA batteries of the same type and brand Changing the Batteries The M130 is powered by three 1 5 volt AA size batteries The BAT icon in upper left of display will activate when battery output drops below a threshold level Approximately 2 hours of life remain from that point Replace all three AA batteries at the same time for best performance To replace the batteries locate the battery compartment at the lower rear of the M130 Remove the screws located at the top center and bottom center of the battery cover by turning them counterclockwise until fully disengaged from the M130 base Remove the cover Do not remove the pink anti static foam that is attached to the inside of the battery cover This foam is necessary to properly secure the batteries under specified shock and vibration conditions Remove the batteries by pulling the positive side first straight out of the battery compartment Note the positive and negative battery polarity markings at the bottom of the compartment as shown below Wwww meriam com ae menam ess technologies Page 18 of 21 ARR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Install the three batteries by sliding
13. exits Edit Setup state between TC type temp unit and of range SIM only Increment MEAS Group SIM Manual Change value Change values Decrement MEAS Group SIM Manual Change value Change values T C Measurement When the M130 is turned on the display defaults to the previous mode it was in with the previous T C type and Unit To change the mode press the FUNC P key until the Measure mode is obtained Once in Measure mode press the lt UNITS key until the desired unit is obtained Press the SETUP key to enter the initial setup menu for the current functional mode To go back one menu item press the lt UNITS key To advance the menu press the FUNC key SETUP key also backs out of the Setup state and returns to the Measure mode Wwww meriam com I N menam process Page 8 of 21 ANR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 e ENTER key accepts the menu item to edit and saves the selection During the SETUP EDIT state the lt UNITS key goes back one increment value and the FUNC key advances one increment value e T C measurements can be recorded to memory either manually or automatically See the Record Mode section of this manual for more information e When an over range under range message is displayed the M130 is measuring values outside the specified range for a particular T C type See the T C Measurement Accuracy Table
14. ime Enclosure 6 5 x 3 2 x 1 1 Polycarbonate Permanently Static Dissipative ESD Protection Enclosure with Boot 6 8 x 3 5 x 1 3 Wwww meriam com PNAN meriam process technologies Page 16 of 21 ARR M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 T C Measurement amp Simulation Accuracy Table Find T C type in left column and follow the row across to the temperature range of interest Then follow the column up to determine the potential error in degrees C T C 3 0 2 0 1 0 0 5 0 4 0 3 0 2 0 1 Type c c c c c c c c 200 to 179 to 15 to 179 C 15 C 1000 C J 200 to 165 to 165 C 1200 C K 200 to 1372 C N 200 to 110 to 110 C 1300 C T 200 to 168 to 86 to 346 to 168 C 86 C 346 C 400 C R 50 to 27 to 736 to 27 C 736 C 1768 C S 50 to 25 to 1179 to 25 C 1179 C 1768 C B 250 to 295 to 605 to 1301 to 295 C 605 C 1301 C 1820 C Notes 1 Accuracy stated above applies to all T C measurements and all manual non ramp T C simulations 2 Cold junction effect at 25 C included in above table Wwww meriam com A menam Page 17 of 21 0 Matt Feteer company M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Certification The M130 is EMI ESD compliant to the test specification EN61326 The M130 is for gen
15. nit selected press enter amp use keys Lower Range Value for T C and unit selected press enter amp use keys Outputs 0 25 50 75 and 100 of setup below Starts 0 ENTER increases 25 to 100 amp back Edit unit for STEP 25 same as above Select T C type same as above Upper Range Value for T C and unit selected press enter amp use keys Lower Range Value for T C and unit selected press enter amp use keys Notes 1 Main and submenus are continuous scrolling menus Use lt or gt to scroll through the menus 2 Use SETUP key to discontinue simulation activity Wwww meriam com Page 11 of 21 meriam aac aaa Wiican lee a Matt Feteer company M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 SIM AUTO SETUP Simulation Mode s Manual menu structure AUTO Press SETUP to enter A STEP 1 Title of Auto Step 1 simulation setup saved here for subsequent re use START Starts A STEP 1 UNITS Select desired unit of simulation C engineering units are C F engineering units are F R engineering units are R K engineering units are K TC TYPE Select T C type or mV mV engineering units are mV only B engineering units are temperature only E engineering units are temperature only J engineering units are temperature only K engineering units are temperature only N engineering units are temperature only R engineering units are temperature only S engineering units are tempera
16. pproximately 20 seconds if not manually turned off To override the auto shut off timer press and hold the BACKLIGHT key to turn the backlight on After holding the key for approximately 2 seconds the backlight will flash off and back on Release the key now and the backlight will remain on until manually turned off or until power is cycled SETUP Key The SETUP key enters or exits the setup mode and is also used to go back one menu level The SETUP icon is displayed while in the setup mode Setup menus are shown in the bottom alpha numeric row of the LCD The SETUP key also ends simulation activities www meriam com AA meram process technologies Page 4 of 21 cee oot M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 FUNCTION Ke The FUNCTION key represented by the FUNC symbol selects one of 3 functional modes Measure Simulate manual or Simulate auto and displays the corresponding icons MEAS SIM This key can also be used to advance one menu item or will advance to next recorded value while in RECORD view mode UNITS Ke The UNITS key selects the engineering unit of measurement simulation desired for temperature probes F C R and K The UNITS function is only available when the M130 is actively measuring or simulating temperature signals This key is also used to go back one menu item in SETUP or back to the previous recorded value while in VIEW mode ENTER Key The ENTER key
17. s displayed Press ENTER The REC icon is shown in upper right Display will show recorded value 1 of X 1 X Pressing ENTER will toggle to show the T C type and engineering unit The lt or P key moves to previous or next recorded value respectively OFF Timer To help conserve battery life the M130 can be programmed to shut off automatically after 30 minutes of keypad inactivity From Measure Mode press SETUP and then lt or gt key until OFF TMR is displayed Press the ENTER key and use or key to display OFF or 30 MIN from menu Press ENTER key to save selection Press SETUP again to return to Measure Mode Zeroing the M130 Preparation Allow the M130 and supplied Shorting Plug p n Z9A83 to soak at room temperature for 30 minutes in a controlled temperature environment Record the room temperature immediately prior to zeroing Zeroing From Measure Mode press SETUP once and then the lt or gt key until F RECAL is displayed Press the ENTER key to display ZERO Press ENTER to start ZERO process Display will show SHORT Install the Shorting Plug white mini T C connector with internal copper short on the M130 s connection and press ENTER key Display will show BUSY When ZERO is successfully completed the message ZERO PASSED is briefly displayed and the M130 is automatically returned to the Measure Mode Remove the Shorting Plug The new temperature reference for the M130 will be the ambient temperature recorded
18. ss enter amp use keys Lower Range Value for T C and unit selected press enter amp use keys Select desired ramp time from LRV to URV press enter amp use keys Select desired ramp time from URV to LRV press enter amp use keys Select desired start delay time for test press enter amp use keys same as A RAMP 1 above A RAMP 3 same as A RAMP 1 above Note 1 Main and submenus are continuous scrolling menus Use lt or gt to scroll through the menus 2 Use SETUP key to discontinue simulation activity Wwww meriam com Page 13 of 21 meriam ae pike Wakes ears a Matt Foeter company M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 Engineering Units Select Engineering Units are conveniently selected when actively measuring or in Manual Simulation mode Press the lt UNITS key to display any of the following C F R K NOTE to display mV units select the mV option under MEAS SETUP TC TYPE The lt UNITS key will not change display units for this TC TYPE Record Mode The M130 can store up to 240 temperature measurements in a single record REC session For maximum flexibility a REC session can be e Automatic the current value is automatically stored every 5 seconds for up to 20 minutes e Manual the current value is stored every time the Enter key is pressed up to 240 times Both types of REC sessions can store between 1
19. them into the bottom of the battery slots positive end first making sure the polarity markings on the batteries align with the markings molded into the battery compartment When a battery is installed with the polarity reversed the stand offs prevent the negative battery terminal from contacting the positive terminal in the battery compartment The unit will not power up in this condition to correct simply reverse the battery to correct the polarity With the batteries secured in the battery compartment replace the compartment cover The cover has only one orientation for correct alignment The WARNING DO NOT OPEN IN EXPLOSIVE ATMOSPHERE statement on the battery cover must be visible and aligned in the approximate middle of the M130 case To secure the cover torque the screws clockwise to 1 6 in lbs Do not over tighten www meriam com aA menam process technologies Page 19 of 21 st M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 2008 User Connections Connection Standard mini T C Connector Measure and Simulate Warning The copper receiver blades of the mini T C connector in the M130 can be damaged if the mating plugs are misaligned during installation Take care to properly align the mating plug prior to pressing it into the M130 s connector Wwww meriam com ae menam ess technologies Page 20 of 21 aana aN M130 T C Calibrator Instruction Manual Z1017 IR E O 6566 Sept 200
20. ture only T engineering units are temperature only URV Upper Range Value for T C and unit selected press enter amp use keys LRV Lower Range Value for T C and unit selected press enter amp use keys STEPS Input number of steps desired for test UP press enter amp use keys DOWN press enter amp use keys DWELL Select desired dwell time for test points Manual Manually advance simulation 5 SEC Auto advance simulation every 5 seconds 10 SEC Auto advance simulation every 10 seconds A STEP 2 same as A STEP 1 above A STEP 3 same as A STEP 1 above A RAMP 1 Title of Auto Ramp 1 simulation setup saved here for subsequent re use START Starts A RAMP 1 UNITS Select desired unit of simulation Cc engineering units are C F engineering units are F R engineering units are R www meriam com a menam Page 12 of 21 ANR M130 T C Calibrator Instruction Manual Z1017 IR K TC TYPE mV Huwmzncmy URV LRV UP TIME DN TIME DELAY A RAMP 2 E O 6566 Sept 2008 engineering units are K Select T C type or mV engineering units are mV only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only engineering units are temperature only Upper Range Value for T C and unit selected pre

Download Pdf Manuals

image

Related Search

Related Contents

Philips 23PFL4509 23" HD-ready Black  Matrix Display HL 970 User's Manual    Structural Engineering Software - Modern Steel Construction  取扱説明書  RC552-FE (A) User Manual  click here for pdf  カタログページ  

Copyright © All rights reserved.
Failed to retrieve file