Home
DOC1033 Rev 1.02a - AM-1 Users Manual
Contents
1. indicator light will turn red if the AM 1 has faulted Reset Switch Will cause the AM 1 to reset The reset switch should not be used for normal operation The reset switch can be used in place of cycling power to reset an unknown password When a controlling device asks you to cycle the power on the product to reset the password you can simply press the reset switch instead of disconnecting the power wires Terminal Connections Terminal Description 1 08 lO1 108 Programmable Input or Output Pins Turnout Feedback Inputs Output Pins Connections for Turnouts OP1 OP4 Voltage Source Connected Power Supply Voltage Ring Engineering Inc 11 BEING RailPro Warranty Limited One Year Warranty Ring Engineering Inc Ring Engineering warrants that for a period of one year from the date of purchase this product will be free from defects in material and workmanship Ring Engineering at its option will repair or replace this product or any component of the product found to be defective during the warranty period Replacement will be made with new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value This is your exclusive warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable Ring Engineering dealers distributors or retail stores selling Rin
2. RING ENGINEERING Model Railroad Accessory Module AM 1 User Manual Ring Engineering Inc 219 322 0279 www RingEngineering com Revision 1 02 Copyright 2012 Ring Engineering Inc All rights reserved BEING RailPro Introduction Thank you for purchasing this Ring Engineering product We take pride in the products that we produce and hope you find this product to be a great addition to your model railroad layout Please read all warnings and instructions before installation and use For the latest information including the latest revision of this manual please visit our Internet site at www RingEngineering com The AM 1 is an Accessory Module that you can add to your model railroad layout to control turnouts Switch Tracks and other products by using a RailPro controller such as the HC 1 handheld controller with color touchscreen Introduction 2 Warnings 3 Direct Radio 3 Installation 3 Passwords 9 Adjustments 9 Advanced Adjustments 10 Feedback Wiring Status Indicator Light N Reset Switch eeseses lt CSW iCits N Terminal Connections _ o Sd Warranty OZO O O OoOO lr FCC Statement 1 Notification Ring Engineering believes that our AM 1 module is compatible with most HO Scale turnouts However it is not practical for Ring Engineering to test our module with all available turnouts Further we cannot control the manufacturing or specification cha
3. a name and a password See the password section for more information on passwords Select TUMOLIE C ce mM al Sam s Junction Name f Password E e Hame Type Styl Ho Hame 5 2 C GEED aria Fi A AN 2 g 3 4 iy D Select Exit Advanced C Exit Eo oo amp Figure 6 Figure 7 Figure 8 AN You must select the proper type of switch before connecting any switches IMPORTANT Be sure to save the settings after you select the proper type of switch Step 5 Connect the Switches A Be sure the power is turned off before connecting any wires to the AM 1 There are three sections below showing how to connect three different types of switches Type 1 Motor Operated slow motion switches Type 2 Snap 3 Wire and Type 3 Snap 2 wire Only one type of switch can be wired to an AM 1 See the section below for the type of switches you will be connecting NOTE Ring Engineering highly recommends using motor operated switches instead of snap type switches Snap type switches can take 100 times the power needed to operate a switch compared to a motor operated switch Ring Engineering Inc 5 BEING RailPro Switch Type 1 Connect Motor Operated slow motion switches Connect Motor operated switches as shown in figure 9 Wire Gauge Recommended 22 AWG or larger Recommended maximum distance 20 j TI em a ee ee N mm pa e ap Ms m me ms e oe mn e ee ee a e we VEE 7 e o a a e
4. als first strip 3 8 of an inch about 2 3 the length of the terminal block of insulation off the wire Then press the orange push button over the contact that you want to connect a wire to Insert the wire into the round hole under the orange push button Be sure the wire goes all the way to the back of the terminal block while holding down on the orange push button When you feel the wire touch the back of the terminal block release the orange button to secure the wire into the terminal block Give the wire a tug to be sure it is securely connected Wire Gauge Minimum 30 Maximum 16 Figure 3 Ring Engineering Inc 4 BEING RailPro Step 3 Find Product on your Controlling Device Power up the AM 1 and press the Find Product button on your controlling device such as the HC 1 handheld controller See your controlling devices manual for more information Main Page Adjust ao Adjust rowel Figure 4 Figure 5 Step 4 Configure the AM 1 for the Type of Switch Configure the AM 1 for the type of switch you are going to be connecting Depending on the type of switch machine you are going to connect to the AM 1 either select a switch type of Motor Operated 3 Wire Snap or 2 Wire Snap On the controlling device go to the turnouts section and select the new turnout module Press the adjustments button to see the switch type At this time you may also want to give this newly detected product
5. cement FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Ring Engineering Inc 12
6. es HR BRING e e Model AM 1 RailPro Accessory Module Figure 9 Only Switch 1 Connections are shown You can connect up to 4 motor operated switches to the AM 1 See table 1 below for the proper terminals to connect the 4 switches to Switch _ Terminals Switch3 O5 O6 07 OB Switch 4 Table 1 NOTE If the switch is displayed in the turn position on the screen and the switch being controlled is in the straight position operating backward then reverse the wiring on that switch to correct the problem For example if Switch 2 is operating backward change wire from O3 to O4 position and wire from O4 to O3 position Ring Engineering Inc 6 BEING RailPro Switch Type 2 Connect 3 Wire Snap Switches Connect 3 wire snap switches as shown in figure 10 Wire Gauge 16 AWG 20 feet or less 18 AWG 12 feet or less 20 AWG 8 feet or less 22 AWG 4 feet or less v id e BRING ce a EE ee N am wa m gt Oe tere Se ee ome ee om ee o e e ee ees ee Model AM 1 RailPro Accessory Module Figure 10 Only Switch 1 Connections are shown You can connect up to four 3 wire snap switches to the AM 1 See table 2 below for the proper terminals to connect the 4 switches Switch Terminals i O05 O6 08 Table 2 A Be sure the coil center tap wire is connected to the terminals labeled OP1 OP4 Be sure the two non center tap wir
7. es are connected to the terminals labeled O1 O8 Only Outputs O1 O8 have redundant power cutout to be sure sustained voltage is not applied to snap switches Snap switch resistance measured from the center wire to either other wire must be between 3 6 and 20 Ohms Never use a switch with more than 20 ohms unless it can have power applied continuously without damage NOTE If the switch is displayed in the turn position on the screen and the switch being controlled is in the straight position operating backward then reverse the wiring on that switch to correct the problem For example if Switch 2 is operating backward change wire from O3 to O4 position and wire from O4 to O3 position TIP If you are not sure which wire is the center wire you can contact the switch manufacturer and ask them Or you can use an electrical multimeter to find out The two wires that read the highest resistances are not the center tap wire A resistance measurement from the center tap to either of the two end wires should measure about half of the resistance as the resistance from one end wire to the other Ring Engineering Inc 7 BRING RailPro Switch Type 3 Connect 2 Wire Snap Switches Connect 2 wire snap switches as shown in figure 11 Wire Gauge 16 AWG 20 feet or less j 18 AWG 12 feet or less 20 AWG 8 feet or less 22 AWG 4 feet or less TE L bep ger BRING am wa am Oe ee ee ss 2o Model AM 1 RailPro Acc
8. essory Module Figure 11 Only Switch 1 Connections are shown You can connect up to four 2 wire snap switches to the AM 1 See table 3 below for the proper terminals to connect the 4 switches to Terminals Switch O1 O2 O3 04 Switch3 O5 O6 Table 3 A Be sure the wires are connected to the terminals labeled O1 O8 Only Outputs O1 O8 have redundant power cutout to be sure sustained voltage is not applied to snap switches Snap switch resistance must be between 3 6 and 20 Ohms Never use a switch with more than 20 ohms unless it can have power applied continuously without damage NOTE If the switch is displayed in the turn position on the screen and the switch being controlled is in the straight position operating backward then reverse the wiring on that switch to correct the problem For example if Switch 2 is operating backward change wire from O3 to O4 position and wire from O4 to O3 position Step 6 Adjust AM 1 for best operation The Activation Time adjustment sets the time the AM 1 will send power to the turnout to get the turnout to change positions It is important that you adjust the Activation Time to only power the turnout just long enough to make the turnout move to a position dependably Ring Engineering Inc 8 BRING RailPro Operate a switch and notice if the switch makes a complete move from the turned position to the straight position and vice versa If the switch does not make
9. g Engineering products do not have the right to alter modify or any way change the terms and conditions of this warranty The warranty does not cover normal wear of parts or damage resulting from negligent misuse of the product Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes Ring Engineering shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty or condition Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty Ring Engineering disclaims all other warranties or conditions express or implied statutory or otherwise Some states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state To obtain warrantee service contact Ring Engineering at Email info ringengineering com or Phone 219 322 0279 to get a return authorization and return instructions If your Ring Engineering product is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or repla
10. ication that is very easy to setup and use Installation Step 1 Mount your AM 1 Position the AM 1 near the products that you plan to wire to the AM 1 under your layout Use at least 2 screws and mount the AM 1 If only using two screws be sure the screws are located in opposite corners The red arrows in figure 1 below identify mounting holes Accessory Module Model AM 1 ENGINEERING Figure 1 Ring Engineering Inc 3 BRING RailPro Step 2 Connect the Power Be sure the power supply you are going to connect to the AM 1 is turned off Then connect power supply to the Power In terminals labeled P1 and P2 with 16 gauge wire coy Accessory Module Model AM 1 BRING Figure 2 AN Only connect a Ring Engineering approved power supply to the proper power input connections such as the PWR 75 Maximum voltage is 16 Volts DC A power supply with excessive voltage or improper voltage can cause a fire Never connect an AC power supply to the AM 1 You can use the output of a DCC booster if it has 3 amps or more of current capability and the DCC system only consists of the signal specified in NMRA standards NOTE The AM 1 is not polarity sensitive You can connect either power supply wire to the P1 or P2 connectors The AM 1 is equipped with spring loaded terminals for fast and secure connections that do not require a tool To connect a wire to the AM 1 termin
11. it all the way to the intended position increase the Activation Time until it does If the switch makes it all the way to the intended position then decrease the Activation Time until it no longer makes the position Then increase Activation Time a little so that each move to a position happens dependably To adjust the Activation Time on the controlling device go into the Adjustments for the AM 1 then go to the Advanced Setup Turnout Setup ce mr MEGEL ce mM Name Password Feedback Sam s Junction Disabled Style Hame Set Position on Power Up Disabled 2 aa Activation Power Up 3 Snap Time Delay Time 20 dD Adyvwihced EIS Set All to a ES Default a Figure 12 Figure 13 Setup Your AM 1 is now ready to use Passwords You can set a password in your AM 1 Further it is recommended that you set a password in your AM 1 right after you receive it When shipped from the factory your AM 1 s password is blank When the password is blank any RailPro controlling device can detect and control your AM 1 Since RailPro uses Direct Radio it is possible to detect and control your AM 1 from over 100 ft away In other words it is possible for your neighbor to control your AM 1 However if you put a password into your AM 1 then your neighbor will not be able to detect or control your AM 1 Note It is ok to give each RailPro accessory module the same password Adjustments Name The reas
12. nges from other manufacturers Itis your responsibility to determine if our module is suitable for your application Ring Engineering is not responsible for any damage that may occur to your equipment from using our AM 1 module Ring Engineering Inc 2 BEING RailPro Warnings e This product is not recommended for persons under the age of fourteen 14 e Only connect a Ring Engineering approved power supply to the proper power input connections Maximum voltage is 16 Volts DC A power supply with excessive voltage or improper voltage can cause a fire You can use the output of a DCC booster if it has 3 amps or more of current capability and the DCC system only consists of the signal specified in NURA standards e Never connect AC power supplies to the AM 1 e Improperly connected products may cause a fire e Only connect products that can handle the voltage of the power supply that is connected Connecting products that are not rated for at least the voltage of the connected power supply may cause a fire e There are no user serviceable parts inside Return to Ring Engineering for repair e This product contains a chemical known to the state of California to cause cancer and birth defects or other reproductive harm This product contains lead DIRECT Direct Radio c RADIO This product is eguipped with Direct Radio Direct Radio is a custom designed RF transceiver to allow this product to have high speed two way commun
13. on to give your AM 1 a name is so you can tell it apart from another AM 1 If you had two or more AM 1 s and did not name them it would be difficult to tell which one you are going to control when you touch the picture of a AM 1 on your controlling device You can give the AM 1 any name that you would like Password It is recommended that you give your AM 1 a password Please read the Password section for more information Ring Engineering Inc 9 BRING RailPro Turnout Type There are three different types of turnouts the AM 1 can control Type 1 Motor Operated slow motion switches Type 2 Snap 3 Wire and Type 3 Snap 2 wire Only one type of turnout can be wired to an AM 1 Turnout Style The turnout style allows you to choose a picture of a turnout like the one you are connecting to the AM 1 such as right hand or left hand turnout Turnout Name You can give any name you would like to each of the four turnouts so you can easily identify them for operation Advanced Adjustments Feedback Enable The controlling device can display the switch position It can use time to show the position or it can show the position based upon actual wired feedback signals Activation Time The Activation Time adjustment sets the time the AM 1 will send power to the turnout to get the turnout to change positions Set Position on Power Up If this option is enabled the AM 1 will wait for the Power Up Delay Time then set the position of each
14. switch to the last commanded position before the power was turned off Power Up Delay Time Is the amount of time the AM 1 will wait before it sets the positions of each switch after a power on This is only used if the Set Position on Power Up is enabled This is used so in a large system that all the turnouts do not try to move at the same time during power up If all the turnouts moved at the same time the power supply could be overloaded Feedback Wiring Auxiliary contacts on the turnouts can be used to feedback actual switch positions so the controlling device s screen can show the actual position One side of each switch must be connected to the R1 or R2 reference voltage terminals The other side needs to be connected to the proper input as shown in table 4 The switches need to be of type normally open and close when the proper switch position is achieved Ring Engineering Inc 10 BRING RailPro 7 a redeerrkreardgi ged di BRING Model AM 1 RailPro Accessory Module Turn Position Straight Position Figure 14 Only Switch 1 Connections are shown Switch Straight Turn 106 Switch4 107 108 Table 4 Status Indicator Light The indicator light will be green when the AM 1 is powered up and ready to be controlled The indicator light is yellow while it is powering up You will need to wait for the indicator light to turn green before using the AM 1 The
Download Pdf Manuals
Related Search
Related Contents
LabVIEW PID Control Toolset User Manual Bernina E 16 Owner's Manual HP Pavilion 17-f028cy Samsung NP450R5GE User Manual (Windows 8) Télécharger le fichier DeLOCK MR11 LED - 1 - はじめに このたびは、ロードメーター「スーパージャンボⅡグランデ」を Samsung 931CW Kullanıcı Klavuzu Comparative Study on Real Time Enhanced Linux Copyright © All rights reserved.
Failed to retrieve file