1. NEUTRAL WIRE NOT REQUIRED FOR 3 WIRE 240 VAC LOADS TO SPA NEUTRAL WIRE FROM SERVICE PANEL REQUIRED FOR ALL LOAD TYPES TO SPA BRANCH SERVICE CIRCUIT PANEL ONE YEAR WARRANTY To all original purchasers of its products Connecticut Electric Switch amp Mfg Co 5508 128 Street E Puyallup WA 98373 warrants its products free from defects in materials and workmanship for the period of one year from the date of purchase Products that fail or become defective during the warranty period shall be repaired or replaced at Connecticut Electric s option without charge within 30 days of receipt of the defective product To obtain warranty replacement or repair contact Connecticut Electric s customer service department at 800 472 3819 to obtain a return goods authorization number RGA and return the product transportation paid Connecticut Electric shall not be responsible for shipping removal and or reinstallation labor or any other associated costs incurred in obtaining warranty replacement PAGE FOUR
2. push the test button on the GFCI The product should not operate Now push the reset button on the GFCI The product should now operate normally If the product fails to operate in this manner there is a ground current flowing indicating the possibility of an electric shock Disconnect the power until the fault has been identified and corrected 4 SAVE THESE INSTRUCTIONS As Of 7 06 Owner s Manual cont d STEP 1 Determine Location The SPA 260 Disconnect should be placed between 5 feet minimum and 10 feet away from your spa or other equipment The disconnect can be mounted on a wall or stand alone on bracketed posts STEP 2 Select Wire Size The following are typical amperage wire sizes 60 Amps 3 Copper 50 Amps 6 Copper 40 Amps 8 Copper 30 Amps 10 Copper Note Four conductors are required to properly power this unit for 120 240 volt applications Check codes to see which wire can be used The SPA 260 disconnect panel can be used on loads up to 60 amps 240 volts If you have a lesser load you would have no need to pull the maximum sized wires The panel is manufactured to work fine with mixed 120 and 240 Volt loads Be sure to check the load requirement of the item s you will be hooking up to ensure adequate power All SPA 260 disconnects require a minimum 12 AWG Neutral to be run from your main electrical source to the Line side Neutral of the disconnect including a ground STEP 3 Wiring Prepar
3. CONNECTICUT ELECTRIC amp SWITCH MFG Co Spa Disconnect Panel SPA 260 OWNER S MANUAL PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND OR OPERATING YOUR SPA DISCONNECT PANEL RETAIN THIS MANUAL FOR FUTURE REFERENCE The SPA 260 Spa Disconnect Panel you have purchased is the finest available anywhere and with proper installation will provide you with years of dependable service Follow instructions carefully For questions or assistance contact your qualified electrical contractor or our Toll Free Assistance number 1 800 730 2557 Before you start on a wiring installation or addition contact your local building inspector for current local and National Electrical Code information Local codes vary but are adopted and enforced to promote safe electrical installations You may need a permit to do electrical work and codes could require your work be checked for safety by an electrical inspector This panel is engineered to meet the requirements of spas fountains swimming lap pools submersible devices and therapeutic equipment but is not limited to these applications IMPORTANT SAFETY INSTRUCTIONS 1 READ AND FOLLOW ALL INSTRUCTIONS 2 WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times 3 WARNING This product is provided with a ground fault circuit interrupter The GFCI must be tested before each use With the product operating
4. ation 1 Turn off the main electrical service 2 Pull out the disconnect handle from the SPA 260 and set aside 3 Remove the two interior cover screws and set aside 4 Remove the appropriate knockout s for your application 1 Drive center knockout inward 2 Alternately drive in or pry up the knockout rings one at a time PAGE TWO Owner s Manual cont d STEP 4 Wiring Pull the conductors coming from your power source house panel into the enclosure To prevent damage to conductor insulation use approved wire clamps conduit bushings and or other methods approved for this purpose Install the two hot wires usually red and black into the lugs marked L1 and L2 Place the neutral white into the neutral bar marked N and the ground wire green or bare into the ground bar marked GRD After the above has been completed you are ready to wire from the contactor to your spa Using the same wire size 1 Install the two hot wires RED into T4 and BLACK into T3 into the two lugs marked at the bottom of the contactor 2 Install the white neutral wire into the lug marked T2 N at the bottom of the contactor 3 Install the green or bare ground wire into the ground bar marked GRD Note Your SPA 260 Disconnect has a factory installed 1 pole 15 amp circuit breaker which can be used as needed or desired Route the appropriate wiring to this load out through the 1 2 knockout When wiring this circuit ethe black wire i
5. s installed into the lug at the bottom of the contactor ethe white wire is installed into the lug at the bottom of the contactor eand the ground wire green or bare into the ground bar marked GRD With the disconnect handle removed and the circuit breaker in the house panel turned off you may now make your connection at the spa or other equipment After the spa has been wired and filled with water turn the circuit breaker to the on position and reinstall the disconnect handle STEP 5 Replace Cover Replace the interior cover making sure you adequately tighten the two mounting screws holding it PAGE THREE Owner s Manual cont d STEP 6 Close Outer Door Lift and close the outer door Under normal operating conditions this outer door should remain unlocked A lock can be used on the door latch for times when the spa or other equipment is not in use LZ CN IL Ti 2N FH 20 4 H connecticu T ELECTRIC T1 T2 N 7D 47 PULL TO DISCONNECT NEUTRAL WIRE FOR 15 AMP BRANCH CIRCUIT MUST BE CONNECTED TO THE NEUTRAL LUG OF THE CONTACTOR