Home
C515C-LM/4RM/8RM AA step
Contents
1. C Infineon Errata Sheet V 1 5 2003 12 Device C515C 8R C515C L Marking Step Step AA Package P MQFP 80 This Errata Sheet describes the deviations from the current user documentation The module oriented classification and numbering system uses an ascending sequence over several derivatives including already solved deviations So gaps inside this enumeration can occur Current Documentation e C515C User s Manual 11 97 e C515C Data Sheet Feb 2003 e Instruction Set Manual 07 2000 Note Devices marked with EES or ES are engineering samples which may not be completely tested in all functional and electrical characteristics therefore they should be used for evaluation only The specific test conditions for EES and ES are documented in a separate Status Sheet Contents SEGUON heir wea eae ke ae E oe eee ee ie eee ere deere Page History List Change Summary 000 eee 2 Functional Deviations 0 00 eee 4 Deviations from Electrical and Timing Specification 10 Application Hints 22 620c60000n eee eee ee See eee eee eee eee eee ee 11 Errata Sheet C515C 8R C515C L Step AA 1 11 K Yang V 1 5 2003 12 C Infineon technologies History List Change Summary Errata Sheet History List Change Summary no previous device step since previous Errata Sheet V1 4 Table 1 Functional Deviations Functional
2. In the interrupt service routine of Timer 0 1 or 2 the WDT must be refreshed If required Idle Mode could be entered again OWD 1 The bit 7 OWDS of SFR IPO cannot be set by software The bit 7 OWDS of SFR IPO cannot be set by software It is inaccurately stated in the manual that this bit can be set by software Workaround None SWPD 1 Corrupt wake up from Software Power Down Mode The problem occurs under following conditions e Wake up from software Power Down Mode through P3 2 INTO pin is used e C515C 8R is clocked by the on chip oscillator with crystal or ceramic resonator During the start up phase of the on chip oscillator of a wake up from software Power Down Mode procedure which follows the latch phase of the P3 2 INTO low signal the Oscillator Watchdog unit enables the clock signal to the CPU although the correct frequency of the clock oscillator has not been reached As a result the CPU is fed with a clock signal which has irregular fast oscillations or wrong clock pulses This wrong internal clock signal causes wrong program execution after the wake up and mutilated ALE and PSEN signals and may lead to a crash of the system Errata Sheet C515C 8R C515C L Step AA 7 11 K Yang V 1 5 2003 12 Infineon Cofion Errata Sheet Functional Deviations Workaround A software workaround is possible Prior to entering the software Power Down Mode the Slow Down Mode must be enabled This slows down the
3. Deviations from Electrical and Timing Specification 3 Deviations from Electrical and Timing Specification DC 5 Minimum value of 3 uA for the logic 0 input current Ports 1 2 3 4 5 7 The minimum value of the logic 0 input current for ports 1 2 3 4 5 and 7 is lower than the specified value li min 3 pA instead of 10 uA Workaround None DC 6 Maximum limit values of the power supply current Ipp for Active Mode and Idle Mode The maximum limit values of the power supply current Ipp for Active Mode and Idle Mode are shown in the table below instead of the specified values stated in the Data Sheet Power Supply Current Parameter Symbol Maximum Limit Values Unit Active Mode C515C 8R 6 MHz lop 17 32 mA C515C LM 10 MHz Ippo 27 18 mA Idle Mode C515C 8R 6 MHz lbp 10 25 mA C515C LM 10 MHz ipp 15 51 mA Active Mode C515C 8R 6 MHz lop 6 20 mA with Slow Down C515C LM 10 MHz bp 7 13 mA enabled Idle Mode with C5150C 8R 6 MHz lbp 5 56 mA Slow Down C515C LM 10 MHz lop 6 12 mA enabled Workaround None Errata Sheet C515C 8R C515C L Step AA 10 11 K Yang V 1 5 2003 12 Infineon Errata Sheet Application Hints 4 Application Hints SSC H1 SSC Baud Rate Generation The following description is not mentioned in the C515C User s manual 11 97 on page 6 72 for SSC baud rate generation BRS 2 0 Divide Example Baudra
4. Short Description Fixed in Change Deviation Step PIN 1 Pins 32 Voce and 35 Vsgg4 are not available for use CAN 2 Unexpected Remote Frame Transmission CAN 3 Description in User s Manual regarding the reception of remote frames and the data length code DLC field is incorrect CAN 4 Flowchart sequence in figure in User s Manual regarding Micro controller handling of the Last Message Object is partly incorrect CAN 5 Description in User s Manual section 6 5 5 regarding the Configuration of the Bit Timing is partly incorrect WDT 1 Watchdog Timer is not halted in Idle Mode OWD 1 The bit 7 OWDS of SFR IPO cannot be set by software SWPD 1 Corrupt wake up from Software Power Down Mode SWPD 2 PSEN signal at exit from Software Power Down UM11 97 Mode wrong description in User s Manual 08 96 HWPD 1 Unspecified hardware Power Down Mode exit behaviour caused by oscillator hysteresis of the XTAL2 input ROM 1 ROM Verification Mode 2 and verification error signaling at Port 3 5 Errata Sheet C515C 8R C515C L Step AA 2 11 K Yang V 1 5 2003 12 C Infineon technologies Errata Sheet History List Change Summary Table 2 AC DC Deviations AC DC Short Description Fixed in Change Deviation Step DC 5 Minimum value of 3 uA for the logic 0 input current New Ports 1 2 3 4 5 7 DC 6 Maximum limit values of the power supply current New Ipp for Active Mode and Idle Mode
5. Table 3 Application Hints Application Short Description Fixed in Change Hint Step SSC H1 SSC Baud Rate Generation Updated Errata Sheet C515C 8R C515C L Step AA 3 11 K Yang V 1 5 2003 12 Infineon Errata Sheet Functional Deviations 2 Functional Deviations PIN 1 Pins 32 Vcce1 and 35 Vsg_e are not available for use For the ROM ROMless version the pins 32 and 35 are NC Not Connected pins instead of Voce and Vsse1 On the target board whether these pins are connected or not to supply will not affect chip performance and behavior Workaround None CAN 2 Unexpected Remote Frame Transmission The on chip CAN module may send an unexpected remote frame with the identifier 0 when a pending transmit request of a message object is disabled by software There are three possibilities to disable a pending transmit request of a message object n 1 14 e Set CPUUPDn element e Reset TXRQn element e Reset MSGVALn element Either of these actions will prevent further transmissions of message object n The symptom described above occurs when the CPU accesses CPUUPD TXRQ or MSGVAL while the pending transmit request of the corresponding message object is transferred to the CAN state machine just before start of frame transmission At this particular time the transmit request is transferred to the CAN state machine before the CPU prevents transmission In this case the transmit request is still accepted fr
6. Timing is partly incorrect As described for the CAN Bit Timing Register High BTR1 the minimum total time requirement for segment 1 and segment 2 is as follows trseg1 23 xt trtseg2 22 xt The total bit time remains at ttgegi tTSeg2 2 7 X tg This correction will be updated to the future versions of the User s Manuals Workaround Not applicable Errata Sheet C515C 8R C515C L Step AA 6 11 K Yang V 1 5 2003 12 Infineon Cofion Errata Sheet Functional Deviations WDT 1 Watchdog Timer is not halted in Idle Mode The Watchdog Timer WDT is not halted in the Idle Mode as defined However during the Idle Mode an overflow condition of the WDT does not initiate an internal reset In such a case the WDT starts a new count sequence Workaround 1 Do not use the Watchdog Timer function in combination with the Idle Mode 2 In case of WDT is running before entry into idle mode to avoid a WDT initiated reset upon exit of the Idle Mode the following methods can be used a The WDT is refreshed immediately upon exit from Idle Mode b A timed interrupt can be used to exit the Idle Mode before the WDT reaches the counter state 7FFCh This can be achieved by using Timer 0 1 or 2 This timer can be programmed to generate an interrupt at a WDT counter state prior to overflow for e g at 7FOOh Prior to entering Idle Mode the WDT can be refreshed and Timer 0 1or 2 can be started immediately to synchronize the WDT
7. ator is detected higher than the internal RC clock due to the stabilized external oscillation signal the watchdog starts the final reset delay sequence which takes typically 1 ms Within that time the clock is still supplied by the RC oscillator and the part is held in reset condition After this reset delay sequence the reset state is left and the controller begins program execution at nominal clock frequency Note This behaviour described above becomes more probable if the HWPD pin is activated in short periods of approx 0 1 10 ms depending on the external oscillator circuitry components However in most applications this problem will not negatively affect the overall system behavior Workaround None Errata Sheet C515C 8R C515C L Step AA 8 11 K Yang V 1 5 2003 12 Infineon Errata Sheet Functional Deviations ROM 1 ROM Verification Mode 2 and verification signaling at Port 3 5 The last block of 16 bytes will always return verification pass in the ROM Verification Mode 2 Therefore it is not possible to verify the contents of these 16 bytes where the ROM is protected Workaround Do not utilize the last block of 16 bytes for code Nevertheless the possibility of erroneous ROM codes in only the last block of 16 bytes is low ROM Verification Mode 1 should be used where the ROM is unprotected Errata Sheet C515C 8R C515C L Step AA 9 11 K Yang V 1 5 2003 12 Infineon Errata Sheet
8. internal CPU clock by a factor of 32 After the start up phase of the on chip oscillator the program must then execute a software delay routine which is located at the wake up from software Power Down Mode interrrupt address 007BH first instruction to be executed after the oscillator start up phase The Slow Down Mode must stay enabled during this delay routine The total delay time of the delay routine should cover the typical oscillator start up time e g 10 ms but depends on the oscillator circuit which is used HWPD 1 Unspecified hardware Power Down Mode exit behavior caused by oscillator hysteresis of the XTAL2 input Due to an insufficient oscillator hysteresis at the XTAL2 input pin leaving of hardware Power Down Mode by the HWPD pin with crystal oscillator operation might produce an unspecified behaviour When the on chip oscillator operates with an external crystal small oscillation signals at the XTAL2 input can be recognized by the frequency comparator in the Oscillator Watchdog unit OWD as a valid clock signal for a short time period directly after leaving hardware Power Down Mode by a low to high transition at pin HWPD Therefore the controller starts with program execution for some clock cycles before the frequency comparator in the OWD detects the first external clock fail condition Thereafter the controller enters the OWD reset state as specified If in the OWD reset state the clock frequency output of the on chip oscill
9. om the CAN state machine However the transfer of the identifier the data length code and the data of the corresponding message object is prevented Then the pre charge values of the internal hidden buffer are transmitted instead this causes to a remote frame transmission with identifier O 11 bit and data length code 0 This behavior occurs only when the transmit request of message object n is pending and the transmit requests of other message objects are not active single transmit request If this remote frame loses arbitration to a data frame with identifier 0 or if it is disturbed by an error frame it is not retransmitted Errata Sheet C515C 8R C515C L Step AA 4 11 K Yang V 1 5 2003 12 Infineon Errata Sheet Functional Deviations Effects to other CAN nodes in the network The effect leads to delays of other pending messages in the CAN network due to the high priority of the Remote Frame Furthermore the unexpected remote frame can trigger other data frames depending on the CAN node s configuration Workaround 1 The behavior can be avoided if a message object is not updated by software when a transmission of the corresponding message object is pending TXRQ element is set and the CAN module is active INIT 0 If a re transmission of a message e g after lost arbitration or after the occurrence of an error frame needs to be cancelled the TXRQ element should be cleared by software as soon a
10. s NEWDAT is reset from the CAN module 2 The nodes in the CAN system ignore the remote frame with the identifier 0 and no data frame is triggered by this remote frame CAN 3 Description in User s Manual regarding the reception of remote frames and the data length code DLC field is incorrect It is inaccurately described in the User s Manual on page 6 94 under Arbitration Registers that When the CAN controller stores a remote frame only the data length code is stored into the corresponding message object The correct should be that the DLC field remains unchanged in the receiving message object and that the CPU has the responsibility to define the DLC of the answering data frame This correction will be updated to the future versions of the User s Manuals Workaround Not applicable Errata Sheet C515C 8R C515C L Step AA 5 11 K Yang V 1 5 2003 12 Infineon Errata Sheet Functional Deviations CAN 4 Flowchart sequence in figure in User s Manual regarding Micro controller handling of the Last Message Object is partly incorrect For the software flowchart figure 6 48 in User s Manual 11 97 the correct would be to first process message contents and then to clear bit NEWDAT process message NEWDAT 0 This correction will be updated to the future versions of the User s Manuals Workaround Not applicable CAN 5 Description in User s Manual section 6 5 5 regarding the Configuration of the Bit
11. te Factor for fosc 8 MHz 2 reserved can only be used for fosc 5 MHz Note This application hint is renamed as SSC H1 Workaround None Application Support Group Singapore Errata Sheet C515C 8R C515C L Step AA 11 11 K Yang V 1 5 2003 12